Loading...
5171CMA Washington Street Part 2www.anvilintl.com 45 CAST IRON Malleable IronCast IronSmall Steel FittingsPipe Nipples &Pipe CouplingsForged SteelFittings & UnionsAnviletsCatawissaJ.B. Smith ProductsCarton InformationNote: See page 37 for pressure-temperature ratings. Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 359 Tee Reducing Size A B C D E F Unit Weight Black NPS DN NPS DN NPS DN in mm in mm in mm in mm in mm in mm lbs kg 31/2 90 31/2 90 11/2 40 13/8 35 13/8 35 27/16 62 23/8 60 23/8 60 31/16 78 8.87 4.02 2 50 15/8 41 15/8 41 27/16 62 25/8 67 25/8 67 33/16 81 9.94 4.51 4 100 1 25 4 100 23/4 70 215/16 75 23/4 70 33/4 95 31/2 89 33/4 95 13.52 6.13 11/2 40 4 100 23/4 70 27/8 73 23/4 70 33/4 95 31/2 89 33/4 95 13.47 6.11 2 50 2 50 111/16 43 17/8 48 23/4 70 211/16 68 29/16 65 31/2 89 11.34 5.14 4 100 23/4 70 23/4 70 23/4 70 33/4 95 31/2 89 33/4 95 13.89 6.30 21/2 65 21/2 65 17/8 48 113/16 47 25/8 67 215/16 75 213/16 73 39/16 90 11.78 5.34 4 100 23/4 70 23/4 70 23/4 70 33/4 95 35/8 92 33/4 95 15.75 7.14 3 80 2 50 111/16 43 19/16 40 23/4 70 211/16 68 29/16 65 31/2 89 10.21 4.63 21/2 65 17/8 48 17/8 48 25/8 67 215/16 75 213/16 73 39/16 90 11.25 5.10 3 80 21/4 57 21/8 54 211/16 68 31/4 83 31/8 79 35/8 92 12.50 5.67 4 100 23/4 70 211/16 68 23/4 70 33/4 95 35/8 92 33/4 95 15.04 6.82 4 100 3/4 20 11/4 32 11/4 32 213/16 73 25/16 59 25/16 59 35/16 84 10.58 4.80 1 25 13/16 22 13/16 22 23/4 70 25/16 59 25/16 59 35/16 84 10.40 4.72 11/4 32 15/16 24 15/16 24 25/8 67 25/16 59 25/16 59 35/16 84 10.38 4.71 11/2 40 17/16 37 17/16 37 211/16 68 27/16 62 27/16 62 35/16 84 10.75 4.88 2 50 111/16 43 111/16 43 23/4 70 211/16 68 211/16 68 31/2 89 11.63 5.27 21/2 65 2 51 2 51 25/8 67 215/16 75 215/16 75 39/16 90 12.85 5.83 3 80 21/4 57 21/4 57 211/16 68 31/4 83 31/4 83 35/8 92 14.12 6.40 5 125 33/8 86 33/8 86 213/16 73 43/8 111 43/8 111 4 102 20.88 9.47 6 150 37/8 98 37/8 98 27/8 73 415/16 125 415/16 125 41/16 103 26.36 11.95 5 125 5 125 2 50 13/4 44 13/4 44 37/16 87 215/16 75 215/16 75 41/8 105 17.43 7.90 21/2 65 21/16 52 21/16 52 33/8 86 33/16 81 33/16 81 41/4 108 18.84 8.54 3 80 25/16 59 25/16 59 31/4 83 31/2 89 31/2 89 41/4 108 20.00 9.07 4 100 213/16 71 213/16 71 33/8 86 4 102 4 102 43/8 111 23.83 10.81 6 150 4 4 100 27/8 73 213/16 71 37/8 98 41/16 103 4 102 415/16 125 30.00 13.61 6 150 21/2 65 2 51 2 51 313/16 97 31/4 83 31/4 83 43/4 121 25.67 11.64 3 80 23/8 60 23/8 60 313/16 97 39/16 90 39/16 90 413/16 122 27.46 12.45 4 100 27/8 73 27/8 73 37/8 98 41/16 103 41/16 103 415/16 125 32.44 14.71 5 125 33/8 86 33/8 86 313/16 97 45/8 117 45/8 117 5 127 37.00 16.78 E B C F D A 46 www.anvilintl.com CAST IRON Note: See page 37 for pressure-temperature ratings. Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 360 Cross Size A B Unit Weight Black NPS DN in mm in mm lbs kg 1/2 15 13/16 22 9/16 14 2.80 1.27 3/4 20 15/16 33 13/16 22 1.03 0.47 1 25 11/2 38 15/16 24 1.59 0.72 11/4 32 13/4 44 11/8 29 2.42 1.10 11/2 40 115/16 49 15/16 33 3.21 1.46 2 50 21/4 57 19/16 40 5.28 2.39 21/2 65 211/16 68 113/16 47 8.07 3.66 3 80 31/8 79 23/16 56 11.84 5.37 4 100 313/16 98 23/4 70 19.63 8.90 5 125 41/2 114 35/16 84 31.16 14.13 6 150 51/8 130 37/8 98 47.67 21.62 FIGURE 361 Cross Reducing Size A B C D E, F G, H Unit Weight NPS DN NPS DN NPS DN NPS DN in mm in mm in mm in mm in mm in mm lbs kg 1 25 1 25 3/4 20 3/4 20 13/16 22 13/16 22 15/16 24 15/16 24 13/8 35 17/16 37 1.30 0.59 11/4 32 11/4 32 1 25 1 25 15/16 24 15/16 24 11/8 29 11/8 29 19/16 40 111/16 43 2.04 0.93 11/2 40 1 25 1 25 1 25 1 25 11/8 29 11/4 32 11/4 32 15/8 41 113/16 47 2.74 1.24 11/4 32 1 25 1 25 1 25 1 25 11/4 32 11/4 32 15/8 41 113/16 47 2.67 1.21 11/2 40 1 25 1 25 1 25 1 25 11/4 32 11/4 32 15/8 41 113/16 47 2.51 1.14 11/4 32 1 25 11/8 29 11/8 29 13/16 22 15/16 24 113/16 47 17/8 48 3.90 1.77 11/4 32 11/8 29 11/8 29 13/8 35 13/8 35 113/16 47 17/8 48 3.95 1.79 2 50 11/2 40 1 25 1 25 11/16 17 11/8 29 17/16 37 17/16 37 13/4 44 2 51 3.57 1.62 11/4 32 1 25 11/8 29 13/16 22 11/2 38 17/16 37 17/8 48 21/8 54 4.25 1.93 11/4 32 13/16 22 13/16 22 11/2 38 11/2 38 17/8 48 21/16 52 4.18 1.90 2 50 1 25 1 25 11/16 17 11/16 17 17/16 37 17/16 37 13/4 44 2 51 3.22 1.46 11/4 32 11/4 32 11/8 29 11/8 29 17/16 37 17/16 37 17/8 48 21/8 54 4.00 1.81 11/2 40 11/2 40 11/4 32 11/4 32 17/16 37 17/16 37 2 51 21/8 54 4.08 1.85 21/2 65 2 50 1 25 1 25 1 25 11/16 17 113/16 47 113/16 47 115/16 49 25/16 59 5.11 2.32 11/2 40 11/2 40 11/4 32 15/16 24 17/8 48 17/8 48 23/16 56 27/16 62 6.13 2.78 2 50 2 50 11/2 38 13/4 44 17/8 48 17/8 48 27/16 62 29/16 65 7.23 3.28 21/2 65 1 25 1 25 1 25 1 25 113/16 47 113/16 47 115/16 49 25/16 59 5.06 2.29 11/4 32 1 25 13/16 22 13/16 22 13/4 44 113/16 47 21/16 52 23/8 60 5.39 2.44 11/4 32 11/8 29 11/8 29 113/16 47 113/16 47 21/16 52 23/8 60 5.26 2.39 11/2 40 11/2 40 11/4 32 11/4 32 17/8 48 17/8 48 23/16 56 27/16 62 5.68 2.58 2 50 2 50 19/16 40 19/16 40 115/16 49 115/16 49 27/16 62 29/16 65 6.82 3.09 3 80 3 80 11/2 40 11/2 40 13/8 35 13/8 35 23/16 56 23/16 56 25/16 59 213/16 73 7.91 3.59 2 50 2 50 15/8 41 15/8 41 23/16 56 23/16 56 29/16 65 215/16 75 8.85 4.01 4 100 4 100 2 50 2 50 2 50 2 50 211/16 68 211/16 68 23/4 70 37/16 87 12.00 5.44 A A AAB B BB F B HD C G E A 50 DN Read as: 80 x 65 x 50 x 32 32 DN 80 DN 65 DN 2 NPS Read as: 3 x 21⁄2 x 2 x 11⁄4 11⁄4 NPS 3 NPS 2 1⁄2 NPS www.anvilintl.com 47 CAST IRON Malleable IronCast IronSmall Steel FittingsPipe Nipples &Pipe CouplingsForged SteelFittings & UnionsAnviletsCatawissaJ.B. Smith ProductsCarton InformationNote: See page 37 for pressure-temperature ratings. FIGURE 366 Screwed Hex Coupling Size Across Flats A BCUnit Weight Black NPS DN in mm in mm in mm lbs kg 1 25 115/16 49 111/16 43 9/16 14 0.82 0.37 Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 487 Flanged Union Gasket Type Size Diam. of Flanges No. of Bolts Unit Weight Black Galv. Assembled with gaskets NPS DN in mm –lbs kg lbs kg 1/2 15 215/16 75 3 1.75 0.79 1.75 0.79 3/4 20 3 76 3 2.00 0.91 2.00 0.91 1 25 31/4 83 3 2.25 1.02 2.25 1.02 11/4 32 43/16 106 4 4.75 2.15 4.75 2.15 11/2 40 43/8 111 4 5.00 2.27 5.00 2.27 2 50 5 127 4 6.50 2.95 6.50 2.95 21/2 65 55/8 143 4 8.50 3.85 8.50 3.85 3 80 63/8 162 4 11.00 4.99 11.00 4.99 31/2 90 67/8 175 4 12.75 5.78 –– 4 100 711/16 195 5 18.00 8.16 18.00 8.16 5 125 815/16 227 5 22.00 9.98 –– 6 150 101/4 260 6 30.00 13.61 30.00 13.61 8 200 1215/16 329 8 51.00 23.13 51.00 23.13 C AB 48 www.anvilintl.com CAST IRON Note: See page 37 for pressure-temperature ratings. Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 367 Concentric Reducer Size A B Unit Weight Black NPS DN NPS DN in mm in mm lbs kg 3/4 20 1/2 15 5/8 16 19/16 40 0.40 0.18 1 25 1/2 (Hex)15 11/16 17 111/16 43 0.54 0.24 3/4 (Hex)20 7/16 11 11/2 38 0.63 0.29 11/4 32 1/2 15 9/16 14 15/8 41 0.84 0.38 3/4 20 1 25 21/8 54 0.90 0.41 1 25 15/16 24 21/8 54 1.07 0.49 11/2 40 1/2 15 1/2 13 15/8 41 1.00 0.45 3/4 20 1/2 13 15/8 41 1.20 0.54 1 25 1/2 13 13/4 44 1.50 0.68 11/4 32 1 25 21/4 57 1.45 0.66 2 50 1/2 15 5/8 16 2 51 2.00 0.91 3/4 20 3/4 19 2 51 1.90 0.86 1 25 3/4 19 2 51 1.83 0.83 11/4 32 13/16 22 21/8 54 1.78 0.81 11/2 40 7/8 22 23/16 56 1.98 0.90 21/2 65 11/2 40 3/4 19 2 51 3.10 1.41 2 50 1 25 29/16 65 2.98 1.35 3 80 3/4 20 15/16 24 21/2 64 4.31 1.95 2 50 11/16 27 23/4 70 3.96 1.80 21/2 65 15/16 24 213/16 73 4.40 2.00 4 100 2 50 13/16 30 215/16 75 6.50 2.95 21/2 65 13/16 30 31/8 79 7.78 3.53 3 80 11/16 27 31/8 79 7.01 3.18 5 125 4 100 11/16 27 35/16 84 10.48 4.75 6 150 4 100 11/8 29 37/16 87 13.83 6.27 5 125 11/8 29 39/16 90 15.53 7.04 8 200 6 150 11/4 32 37/8 98 29.10 13.20 AB www.anvilintl.com 49 CAST IRON Malleable IronCast IronSmall Steel FittingsPipe Nipples &Pipe CouplingsForged SteelFittings & UnionsAnviletsCatawissaJ.B. Smith ProductsCarton InformationNote: See page 37 for pressure-temperature ratings. FIGURE 368 Eccentric Reducer Size A B* Unit Weight Black NPS DN NPS DN in mm in mm lbs kg 3/4 20 1/2 15 9/16 14 11/2 38 0.45 0.20 1 25 1/2 15 1/2 13 17/16 37 0.57 0.26 3/4 20 7/16 11 11/2 38 0.61 0.28 11/4 32 1/2 15 9/16 14 15/8 41 1.00 0.45 3/4 20 1/2 13 15/8 41 0.90 0.41 1 25 1/2 13 111/16 43 1.00 0.45 11/2 40 1/2 15 11/16 17 13/4 44 1.11 0.50 3/4 20 9/16 14 111/16 43 1.17 0.53 1 25 9/16 14 13/4 44 1.21 0.55 11/4 32 5/8 16 17/8 48 1.26 0.57 2 50 1/2 15 3/4 19 115/16 49 1.80 0.82 3/4 20 3/4 19 2 51 1.83 0.83 1 25 11/16 17 21/16 52 1.86 0.84 11/4 32 13/16 22 21/8 54 1.87 0.85 11/2 40 7/8 22 23/16 56 1.93 0.88 21/2 65 1 25 13/16 22 21/4 57 2.74 1.24 11/4 32 7/8 22 23/8 60 2.80 1.27 11/2 40 7/8 22 23/8 60 2.94 1.33 2 50 1 25 29/16 65 2.95 1.34 3 80 1 25 7/8 22 27/16 62 3.95 1.79 11/4 32 15/16 24 29/16 65 3.80 1.72 11/2 40 15/16 24 29/16 65 4.16 1.89 2 50 11/16 27 23/4 70 4.61 2.09 21/2 65 15/16 24 213/16 73 4.80 2.18 31/2 90 2 50 11/16 27 23/4 70 5.23 2.37 4 100 11/4 32 11/16 27 23/4 70 6.58 2.98 11/2 40 11/8 29 213/16 73 6.61 3.00 2 50 13/16 30 215/16 75 6.91 3.13 21/2 65 11/8 29 31/16 78 7.26 3.29 3 80 11/16 27 31/8 79 7.64 3.46 5 125 21/2 65 11/8 29 33/16 81 11.38 5.16 3 80 11/16 27 31/4 83 11.44 5.19 4 100 11/16 27 35/16 84 11.19 5.07 6 150 3 80 11/16 27 35/16 84 14.66 6.65 4 100 11/8 29 37/16 87 15.36 6.97 * Dimension “B” does not conform to ASME standard. Cast Iron Threaded Fittings Class 125 (Standard) A B 50 www.anvilintl.com CAST IRON Note: See page 37 for pressure-temperature ratings. Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 383 Hex Bushing Size Unit Weight Black Galv. NPS DN Hex All Cast Iron NPS DN lbs kg lbs kg Inside hex See page 35 (Malleable Iron) for other available sizes. 11/2 40 C 1/4 8 0.47 0.21 0.47 0.21 C 3/8 10 0.47 0.21 0.47 0.21 C 1/2 15 0.42 0.19 0.42 0.19 C 3/4 20 0.47 0.21 0.47 0.21 C125 0.50 0.23 0.50 0.23 2 50 C 1/4 8 0.75 0.34 0.75 0.34 C 3/8 10 0.75 0.34 0.75 0.34 C 1/2 15 0.70 0.32 0.70 0.32 C 3/4 20 0.71 0.32 0.71 0.32 C125 0.73 0.33 0.73 0.33 C11/4 32 0.81 0.37 0.81 0.37 21/2 65 C 1/2 15 1.28 0.58 1.28 0.58 C 3/4 20 1.25 0.57 1.25 0.57 C125 1.16 0.53 1.16 0.53 C11/4 32 1.24 0.56 1.24 0.56 C11/2 40 1.29 0.59 1.29 0.59 3 80 C 1/2 15 1.93 0.88 1.93 0.88 C 3/4 20 1.92 0.87 1.92 0.87 C125 1.90 0.86 1.90 0.86 C11/4 32 1.77 0.80 1.77 0.80 C11/2 40 1.79 0.81 1.79 0.81 C250 1.90 0.86 1.90 0.86 C21/2 65 1.63 0.74 1.63 0.74 31/2 80 C125 2.42 1.10 2.42 1.10 C11/4 32 2.56 1.16 2.56 1.16 C11/2 40 2.65 1.20 2.65 1.20 C250 2.54 1.15 2.54 1.15 C21/2 65 3.23 1.46 3.23 1.46 C380 1.96 0.89 1.96 0.89 Continued on next page. According to specifications, hex bushings and cored plugs should be used with 150# malleable iron and 125# cast iron. Solid plugs and face bushings are recommended for use with 250# and 300# fittings. www.anvilintl.com 51 CAST IRON Malleable IronCast IronSmall Steel FittingsPipe Nipples &Pipe CouplingsForged SteelFittings & UnionsAnviletsCatawissaJ.B. Smith ProductsCarton InformationNote: See page 37 for pressure-temperature ratings. FIGURE 383 Hex Bushing Size Unit Weight Black Galv. NPS DN Hex All Cast Iron NPS DN lbs kg lbs kg Inside hex See page 35 (Malleable Iron) for other available sizes. 4 100 C125 3.59 1.63 3.59 1.63 C11/4 32 3.54 1.61 3.54 1.61 C11/2 40 3.44 1.56 3.44 1.56 C250 3.11 1.41 3.11 1.41 C21/2 65 3.29 1.49 3.29 1.49 C380 3.15 1.43 3.15 1.43 C31/2 90 2.50 1.13 2.50 1.13 5 125 C250 5.12 2.32 5.12 2.32 C21/2 65 4.87 2.21 4.87 2.21 C380 4.83 2.19 4.83 2.19 C31/2 90 4.00 1.81 –– C4100 3.94 1.79 3.94 1.79 6 150 C250 8.00 3.63 8.00 3.63 C21/2 65 7.72 3.50 –– C380 7.75 3.51 7.75 3.51 C4100 6.83 3.10 6.83 3.10 C5125 5.24 2.38 5.24 2.38 8 200 C380 15.50 7.03 –– C4100 13.93 6.32 –– C5125 13.65 6.19 –– C6150 13.19 5.98 13.19 5.98 10 250 C6150 24.50 11.11 –– C8200 22.00 9.98 –– Continued from previous page. Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 385 Face Bushing Size Unit Weight Black See page 35 (Malleable Iron) for other available sizes. NPS DN NPS DN lbs kg 3 80 2 50 13.30 6.03 4 100 21/2 65 2.55 1.16 3 80 19.20 8.71 According to specifications, hex bushings and cored plugs should be used with 150# malleable iron and 125# cast iron. Solid plugs and face bushings are recommended for use with 250# and 300# fittings. 52 www.anvilintl.com CAST IRON Note: See page 37 for pressure-temperature ratings. Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 387 Square Head Plugs, Cored Size Unit Weight Black Galv. NPS DN lbs kg lbs kg 3/4 20 0.13 0.06 0.13 0.06 1 25 0.25 0.11 0.25 0.11 11/4 32 0.39 0.18 0.39 0.18 11/2 40 0.50 0.23 0.50 0.23 2 50 0.82 0.37 0.82 0.37 21/2 65 1.32 0.60 1.32 0.60 3 80 1.87 0.85 1.87 0.85 31/2 90 2.50 1.13 2.50 1.13 4 100 4.00 1.81 4.00 1.81 FIGURE 388 Square Head Plugs, Solid Size Unit Weight Black Galv. NPS DN lbs kg lbs kg 1/2 15 0.10 0.05 0.10 0.05 3/4 20 0.17 0.08 0.17 0.08 1 25 0.32 0.15 0.32 0.15 11/4 32 0.53 0.24 0.53 0.24 11/2 40 0.76 0.34 0.76 0.34 2 50 1.23 0.56 1.23 0.56 21/2 65 2.00 0.91 2.00 0.91 3 80 3.18 1.44 3.18 1.44 31/2 90 4.38 1.99 –– FIGURE 380 Bar Plugs, Solid Size Unit Weight Black NPS DN lbs kg 4 100 5.68 2.58 5 125 9.60 4.35 6 150 14.78 6.70 FIGURE 389 Bar Plugs, Cored Size Unit Weight Black Galv. NPS DN lbs kg lbs kg 4 100 3.82 1.73 3.82 1.73 5 125 6.50 2.95 6.50 2.95 6 150 9.94 4.51 9.94 4.51 8 200 20.26 9.19 20.26 9.19 FIGURE 390 Countersunk Plugs Size Unit Weight Black Galv. See page 32 (Malleable Iron) for other available sizes. NPS DN lbs kg lbs kg 1 25 0.20 0.09 0.20 0.09 11/4 32 0.32 0.15 0.32 0.15 11/2 40 0.47 0.21 0.47 0.21 2 50 0.84 0.38 0.84 0.38 21/2 65 1.40 0.63 –– 3 80 2.25 1.02 –– 31/2 90 3.02 1.37 –– 4 100 3.76 1.71 –– FIGURE 381 Cap Size Unit Weight Black Galv. NPS DN lbs kg lbs kg 21/2 65 2.55 1.16 –– 3 80 4.10 1.86 –– 4 100 6.40 2.90 –– 5 125 10.70 4.85 –– 6 150 14.20 6.44 14.20 6.44 8 200 27.23 12.35 27.23 12.35 According to specifications, hex bushings and cored plugs should be used with 150# malleable iron and 125# cast iron. Solid plugs and face bushings are recommended for use with 250# and 300# fittings. www.anvilintl.com 53 CAST IRON Malleable IronCast IronSmall Steel FittingsPipe Nipples &Pipe CouplingsForged SteelFittings & UnionsAnviletsCatawissaJ.B. Smith ProductsCarton InformationNote: See page 37 for pressure-temperature ratings. Cast Iron Threaded Fittings Class 125 (Standard) FIGURE 370 Locknut Size Minimum Dimensions Unit Weight A B C D Black For nominal sizes smaller than 21⁄2" (65 DN) see Malleable Iron page 27. NPS DN in mm in mm in mm in mm lbs kg 21/2 65 3.500 89 3.180 81 .590 15 0.90 2 1.13 0.51 3 80 4.270 108 3.840 98 .670 17 0.90 2 1.60 0.73 4 100 5.380 137 5.000 127 .800 20 .130 3 1.10 0.50 Cast Iron Threaded Fittings Class 250 (Extra Heavy) FIGURE 421 90˚ Elbow Size A B Unit Weight Black NPS DN in mm in mm lbs kg 1/4 8 5/8 16 15/16 24 0.37 0.17 1/2 15 13/16 22 11/4 32 0.75 0.34 3/4 20 15/16 24 17/16 37 1.13 0.51 1 25 11/16 27 15/8 41 1.79 0.81 11/4 32 15/16 33 115/16 49 3.00 1.36 11/2 40 11/2 38 21/8 54 4.05 1.84 2 50 113/16 47 21/2 64 6.76 3.07 21/2 65 2 51 215/16 75 10.56 4.79 3 80 23/8 60 33/8 86 15.25 6.92 A A B B FIGURE 424 45˚ Elbow Size A B Unit Weight Black NPS DN in mm in mm lbs kg 1/2 15 9/16 14 1 25 0.66 0.30 3/4 20 5/8 16 11/8 29 1.04 0.47 1 25 3/4 19 15/16 33 1.56 0.71 11/4 32 7/8 22 11/2 38 2.70 1.22 11/2 40 11/16 27 111/16 43 3.55 1.61 2 50 15/16 33 2 51 6.07 2.75 21/2 65 15/16 33 21/4 57 9.79 4.44 B BA A victaulic.com 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. 1.0 PRODUCT DESCRIPTION Available Sizes • 1 ¼ – 8"/DN32 – DN200 Maximum Working Pressure • Pressure ratings for Victaulic FireLock™ Fittings conform to the ratings of Victaulic FireLock EZ™ Style 009N couplings (refer to publication 10.64 for more information). Application • FireLock™ fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials • Carbon steel 2.0 CERTIFICATION/LISTINGS EN 10311 Regulation (EU) No. 305/2011 3.0 SPECIFICATIONS – MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: Orange enamel. Red enamel in Europe, Middle East, Africa, and India. Optional: Hot dipped galvanized. Victaulic® FireLock™ Fittings 10.03 1 System No.Location Submitted By Date Spec Section Paragraph Approved Date 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 4.0 DIMENSIONS C to E C to E C to E C to E C to E T No. 001 No. 003 No. 002 No. 006 Nominal Size Actual Outside Diameter No. 001 90° Elbow No. 003 45° Elbow No. 002 Straight Tee No. 006 Cap C to E Approximate Weight Each C to E Approximate Weight Each C to E Approximate Weight Each T Approximate Weight Each inches DN inches mm inches mm lb kg inches mm lb kg inches mm lb kg inches mm lb kg 1 1/4 1.660 — — — — — — — — — — — — 0.82 0.3 DN32 42.4 21 0.1 1 1/2 1.900 ——————0.82 0.4 DN40 48.3 ——————21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DN50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 2 1/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 DN65 3.000 3.00 3.30 2.25 2.4 3.00 3.8 ——76.1 76 1.5 57 1.1 76 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 ——108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 3.8 124 7.1 25 1.9 DN125 5.500 4.88 12.4 3.25 8.2 4.88 15.4 ——139.7 124 5.6 82.6 3.7 124 6.9 6.250 5.50 12.6 3.50 9.2 5.50 17.9 ——158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 ——165.1 140 7.9 89 5.2 140 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 23.1 ——6.94 33.6 —— 216.3 173 10.5 ——176 15.2 —— 2 victaulic.com 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe1 Nominal Size Actual Outside Diameter Elbows No. 002 Straight Tee No. 001 90° Elbow No. 003 45° Elbow Branch Run inches DN inches mm feet meters feet meters feet meters feet meters 1 1/4 1.660 ———— DN32 42.4 ———— 1 1/2 1.900 ———— DN40 48.3 ———— 2 2.375 3.5 1.8 8.5 3.5 DN50 60.3 1.1 0.5 2.6 1.1 2 1/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 DN65 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 1.3 6.4 2.6 DN125 5.500 8.3 4.1 20.6 8.3 139.7 2.5 1.3 6.3 2.5 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN150 168.3 3.0 1.5 7.6 3.0 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1.5 10.1 4.0 8.515 13.0 —33.0 13.0 216.3 4.0 —10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. 3 victaulic.com 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 6.0 NOTIFICATIONS General Notes NOTE: When assembling FireLock EZ™ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ™ Style 009N/009H couplings, use FireLock™ No. 006 end caps containing the “EZ” marking on the inside face or No. 60 end caps containing the “QV EZ” marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64: Victaulic® FireLock™ Rigid Coupling Style 009N 10.02: Victaulic® FireLock™ Rigid Coupling Style 005H with Vic-Plus™ Gasket System 29.01: Victaulic® Terms and Conditions of Sale 4 victaulic.com FLANGED FITTINGS Flanges and Accessories ANSI B16.1 Class 125/250 apac,apac,apac,apac,apac,NNNNNIIIIInc.nc.nc.nc.nc. apac,apac,apac,apac,apac,NNNNNIIIIInc.nc.nc.nc.nc. ORDERS FAX 800-807-2214 DESIGNATION of OUTLETS In accordance with ANSI B16.1 REDUCING TEES REDUCING LATERAL REDUCING ON OUTLET REDUCING ON ONE RUN REDUCING ON ONE RUN AND OUTLET REDUCING ON BOTH RUNS (BULLHEAD) REDUCING ON BRANCH The largest opening establishes the basic size of a reducing fitting. The largest opening is named first, except for bullhead tees, which are reducing on both runs, and for double branch elbows where both branches are reducing. The outlet is the largest opening and named last in both cases. In designating the openings of reducing fittings, they should be read in the order indicated by the sequence of the letters a, b, c. UNITED BRAND FITTINGS Our dedication to the mechanical piping industry has given us the opportunity to provide you with a quality line of flanged fittings exceeding the competition. Manufactured from high strength grey cast iron and ductile iron, our Flanged Fittings Series are available in 1” - 24” sizes in a variety of elbows, tees, crosses, laterals, reducers, and blind flanges. All are manufactured in accordance with ANSI B16.1, and all are available with special rust inhibitive primers and epoxy coatings. aaaaa bbbbb c cccc 2 UNITED BRAND FITTINGS FLANGE DETAILS - Class 125 All dimensional data in inches and lbs. eziS.D.O.C.BT eloHtloB .aiD &.aiDtloB htgneL fo.oN stloB 2 00.6 05.4 8/5 4/3 2/12x8/5 4 2/1200.700.561/114/32/12x8/54 3 05.7 00.6 4/3 4/3 2/12x8/5 4 400.905.761/514/33x8/58 5 00.01 05.8 61/51 8/7 2/13x4/3 8 600.1105.91 8/72/13x4/38 8 05.31 57.11 8/11 8/7 2/13x4/3 8 0100.6152.4161/311 4x8/721 21 00.91 00.71 4/11 1 4x8/7 21 4100.1257.818/318/112/14x121 61 05.32 52.12 61/71 8/11 2/14x1 61 8100.5257.2261/914/115x8/1161 02 05.72 00.52 61/111 4/11 5x8/11 02 4200.2305.928/718/312/15x4/1102 ORDERS FAX 800-807-2214 SERIES 10 90o SERIES 11 45o SERIES 12 22 1/2o SERIES 13 11 1/4o UNITED BRAND FITTINGS ELBOWS *14”~24” are made from high strength ductile iron to ANSI A21.10, AWWA C110, WWP 250. 90o REDUCING ELBOW ANSI B16.1 Class 125 ANSI B16.1 Class 125 3 SERIES 10R *14”~24” are made from high strength ductile iron to ANSI A21.10, AWWA C110, WWP 250. eziS.oNtraPART1TthgieW 2x3 G-2030-F01 5.5 0.4 83.13.91 2/12x3G-52030-F015.50.483.13.22 2x4 G-2040-F01 5.6 0.4 05.13.92 2/12x4G-52040-F015.60.405.13.13 3x4 G-3040-F01 5.6 5.4 05.83.33 4x5G-4050-F015.70.505.05.84 3x6 G-3060-F01 0.8 0.6 65.83.54 4x6G-4060-F010.80.665.05.55 5x6 G-5060-F01 0.8 0.6 65.05.56 4x8G-4080-F010.90.726.05.57 5x8 G-5080-F01 0.9 0.7 26.65.08 6x8G-6080-F010.90.726.65.58 4x01 G-4001-F01 0.11 0.9 57.05.011 6x01G-6001-F010.110.957.65.531 8x01 G-8001-F01 0.11 0.9 57.26.051 4x21G-4021-F010.210.0118.05.041 6x21 G-6021-F01 0.21 0.01 18.65.061 8x21G-8021-F010.210.0118.26.081 01x21 G-0121-F01 0.21 0.01 18.57.012 *21x41D-2141-F010.415.1166.57.072 *21x61 D-2161-F01 0.51 5.21 07.57.013 *41x61D-4161-F010.515.2107.66.033 eziS 09o woblE54owoblE2/122 o woblE4/111 o woblE T.oNtraPAR.tgW.oNtraPAR.tgW.oNtraPAR.tgW.oNtraPAR.tgW 2 G-2020-F01 5.4 0.3 41 G-2020-F11 5.2 4.2 21 --------13. 2/12G-520520-F010.55.391G-520520-F110.36.371--------13. 3 G-3030-F01 5.5 0.4 52 G-3030-F11 0.3 6.3 02 G-3030-F21 0.3 6.7 02 G-3030-F31 0.3 52.51 02 83. 4G-4040-F015.65.454G-4040-F110.48.404G-4040-F210.460.0104G-4040-F310.413.020405. 5 G-5050-F01 5.7 5.5 25 G-5050-F11 5.4 0.6 54 --------05. 6G-6060-F010.80.656G-6060-F110.53.755G-6060-F210.560.5155G-6060-F310.505.035565. 8 G-8080-F01 0.9 0.7 501 G-8080-F11 5.5 4.8 09 G-8080-F21 5.5 26.71 09 G-8080-F31 5.5 05.53 09 26. 01G-0101-F010.110.9561G-0101-F115.69.01031G-0101-F215.626.22531G-0101-F315.696.5453157. 21 G-2121-F01 0.21 0.01 532 G-2121-F11 5.7 3.31 591 G-2121-F21 5.7 26.72 502 G-2121-F31 5.7 18.55 502 18. *41D-4141-F010.415.11092D-4141-F115.760.21022--------66. *61 D-6161-F01 0.51 5.21 073 D-6161-F11 0.8 52.31 082 --------07. *81D-8181-F015.610.41054D-8181-F115.805.41523--------57. *02 D-0202-F01 0.81 5.51 085 D-0202-F11 5.9 88.61 034 --------08. *42D-4242-F010.225.81009D-4242-F110.1121.81036--------98. ORDERS FAX 800-807-2214 UNITED BRAND FITTINGS 90o LONG RADIUS ELBOW 90o BASE ELBOW SERIES 15 SERIES 16 SIDE OUTLET 90o ELBOW ANSI B16.1 Class 125 ANSI B16.1 Class 125 ANSI B16.1 Class 125 Larger sizes thru 24” available upon request. Larger sizes thru 24” available upon request. Larger sizes thru 24” available upon request. T A R SERIES 18 4 eziS.oNtraPBRTthgieW 3 G-3030-F51 5.7 0.6 83.82 4G-4040-F510.90.705.84 6 G-6060-F51 5.11 5.9 65.58 8G-8080-F510.410.7126.541 01 G-0101-F51 5.61 0.41 57.032 21G-2121-F510.910.7118.053 eziS.oNtraPR).aiD(STU thgieW 3 G-3030-F61 0.4 0.5 82.05.63 4G-4040-F615.50.626.05.55 6 G-6060-F61 0.7 0.7 96.26.58 8G-8080-F6183.80.949.88.541 01 G-0101-F61 57.9 0.9 49.88.012 21G-2121-F6152.110.110.10.1003 eziS.oNtraPARTthgieW 4 G-4040-F81 5.6 5.6 05.06 6G-6060-F810.80.865.59 8 G-8080-F81 0.9 0.9 26.051 01G-0101-F810.110.1157.532 21 G-2121-F81 0.21 0.21 18.533 ORDERS FAX 800-807-2214 UNITED BRAND FITTINGS TEES & CROSSES REDUCING TEE (on Run and/or Branch) SERIES 26 SERIES 35 SERIES 20 ANSI B16.1 Class 125 Larger sizes thru 24” available upon request. ANSI B16.1 Class 125 5 *14”~24” are made from high strength ductile iron to ANSI A21.10, AWWA C110, WWP 250. eziS.oNtraPHJT1TthgieW 4x3x4 G-4340-F62 5.6 5.6 05.83.95 4x4x6G-4460-F620.80.865.05.09 6x4x6 G-6460-F62 0.8 0.8 65.05.59 8x4x8G-8480-F620.90.926.05.641 4x6x8 G-4680-F62 0.9 0.9 26.65.521 6x6x8G-6680-F620.90.926.65.541 8x6x8 G-8680-F62 0.9 0.9 26.65.061 8x8x01G-8801-F620.110.1157.26.232 01x8x01 G-01801-F62 0.11 0.11 57.26.262 8x8x21G-8821-F620.210.2118.26.892 01x01x21 G-010121-F62 0.21 0.21 18.57.043 21x01x21G-210121-F620.210.2118.57.563 eziS .oNtraP HJT1T thgieW eeTssorCeeTssorC 2 G-2020-F02 G-2020-F53 5.4 5.4 13.13.02 03 2/12G-520520-F02G-520520-F530.50.513.13.0393 2x3 G-2030-F02 -5.5 5.5 83.13.53 - 2/12x3G-52030-F02-5.55.583.13.83- 3 G-3030-F02 G-3030-F53 5.5 5.5 83.13.04 05 2x4G-2040-F02-5.65.605.13.05- 2/12x4 G-52040-F02 -5.6 5.6 05.13.55 - 3x4G-3040-F02-5.65.605.83.06- 4 G-4040-F02 G-4040-F53 5.6 5.6 05.05.56 08 5G-5050-F02G-5050-F535.75.705.05.58501 2x6 G-2060-F02 -0.8 0.8 65.13.68 - 3x6G-3060-F02-0.80.865.83.58- 4x6 G-4060-F02 G-4060-F53 0.8 0.8 65.05.09 011 6G-6060-F02G-6060-F530.80.865.65.59021 3x8 G-3080-F92 -0.9 0.9 26.83.041 - 4x8G-4080-F02-0.90.926.05.041- 6x8 G-6080-F02 G-6080-F53 0.9 0.9 26.65.541 561 8G-8080-F02G-8080-F530.90.926.26.551591 3x01 G-3001-F02 -0.11 0.11 57.83.002 - 4x01G-4001-F02-0.110.1157.05.502- 6x01 G-6001-F02 -0.11 0.11 57.65.512 - 8x01G-8001-F02-0.110.1157.26.522- 01 G-0101-F02 G-0101-F53 0.11 0.11 57.57.072 033 4x21G-4021-F02-0.210.2118.05.092- 6x21 G-6021-F02 -0.21 0.21 18.65.592 - 8x21G-8021-F02-0.210.2118.26.013- 01x21 G-0121-F02 -0.21 0.21 18.57.063 - 21G-2121-F02G-2121-F530.210.2118.18.583064 *41 D-4141-F02 D-4141-F53 0.41 0.41 66.66.534 - *61D-6161-F02D-6161-F530.510.5107.07.055- *81 D-8181-F02 D-8181-F53 5.61 5.61 57.57.566 - *02D-0202-F02D-0202-F530.810.8108.08.558- *42 D-4242-F02 D-4242-F53 0.22 0.22 98.98.0331 - ORDERS FAX 800-807-2214 ANSI B16.1 Class 125 UNITED BRAND FITTINGS BULLHEAD TEE ANSI B16.1 Class 125 Larger sizes thru 24” available upon request. SERIES 27 Larger sizes thru 24” available upon request. LATERAL WYES SERIES 30 ANSI B16.1 Class 125 Larger sizes thru 24” available upon request. 6 TRUE WYES SERIES 32 eziS.oNtraP A BCT 1TthgieW 3 G-3030-F03 0.01 0.3 0.01 83.-54 4G-4040-F030.210.30.2105.- 57 6 G-6060-F03 5.41 5.3 5.41 65.-021 4x6G-4060-F035.415.35.4165.05.501 8 G-8080-F03 5.71 5.4 5.71 26.-002 6x8G-6080-F035.715.45.7126.65.571 01 G-0101-F03 5.02 0.5 5.02 57.-533 21G-2121-F035.425.55.4218.- 515 eziS.oNtraPABTthgieW 4 G-4040-F23 5.6 0.3 05.05 6G-6060-F230.85.365.08 8 G-8080-F23 0.9 5.4 26.521 eziS.oNtraPHJT1TthgieW 6x4x4 G-6440-F72 0.8 0.8 05.65.88 8x6x6G-8660-F720.90.965.26.241 01x8x8 G-01880-F72 0.11 0.11 26.57.042 21x01x01G-210101-F720.210.2157.18.043 ORDERS FAX 800-807-2214 UNITED BRAND FITTINGS CONCENTRIC & ECCENTRIC REDUCERS ANSI B16.1 Class 125 7 (ECCENTRIC) SERIES 51 (CONCENTRIC) SERIES 50 *14”~24” are made from high strength ductile iron to ANSI A21.10, AWWA C110, WWP 250. eziS .oNtraP )cirtnecnoC( .oNtraP )cirtneccE(LT1TthgieW 2/11x2 G-52020-F05 -5.5 13.03.21 2x2/12G-20520-F05-5.513.13.41 2/11x3 G-51030-F05 -6 83.03.51 2x3G-2030-F05G-2030-F15683.13.61 2/12x3 G-52030-F05 G-52030-F15 6 83.13.02 2x4G-2040-F05G-2040-F15705.13.52 2/12x4 G-52040-F05 G-52040-F15 7 05.13.82 3x4G-3040-F05G-3040-F15705.83.03 2/12x5 G-52050-F05 G-52050-F15 8 05.13.13 3x5G-3050-F05G-3050-F15805.83.23 4x5 G-4050-F05 G-4050-F15 8 05.05.93 2/12x6G-52060-F05G-52060-F15965.13.83 3x6 G-3060-F05 G-3060-F15 9 65.83.04 4x6G-4060-F05G-4060-F15965.05.54 5x6 G-5060-F05 G-5060-F15 9 65.05.05 4x8G-4080-F05G-4080-F151126.05.56 5x8 G-5080-F05 G-5080-F15 11 26.05.07 6x8G-6080-F05G-6080-F151126.65.57 4x01 G-4001-F05 G-4001-F15 21 57.05.58 5x01F-5001-F05G-5001-F152157.05.88 6x01 G-6001-F05 G-6001-F15 21 57.65.09 8x01G-8001-F05G-8001-F152157.26.011 4x21 G-4021-F05 G-4021-F15 41 18.05.021 6x21G-6021-F05G-6021-F154118.65.031 8x21 G-8021-F05 G-8021-F15 41 18.26.541 01x21G-0121-F05G-0121-F154118.57.071 *6x41 D-6041-F05 D-6041-F15 61 66.55.551 *8x41D-8041-F05D-8041-F156166.06.571 *01x41 D-0141-F05 D-0141-F15 61 66.86.091 *21x41D-2141-F05D-2141-F156166.57.022 *6x61 D-6061-F05 D-6061-F15 81 07.55.091 *8x61D-8061-F05D-8061-F158107.06.012 *01x61 D-0161-F05 D-0161-F15 81 07.86.532 *21x61D-2161-F05D-2161-F158107.57.562 *41x61 D-4161-F05 D-4161-F15 81 07.66.082 *8x81D-8081-F05D-8081-F159157.06.042 *01x81 D-0181-F05 D-0181-F15 91 57.86.562 *21x81D-2181-F05D-2181-F159157.57.592 *41x81 D-4181-F05 D-4181-F15 91 57.66.013 *61x81D-6181-F05D-6181-F159157.07.043 *01x02 D-0102-F05 D-0102-F15 02 08.86.013 *21x02D-2102-F05D-2102-F150208.57.543 *41x02 D-4102-F05 D-4102-F15 02 08.66.553 *61x02D-6102-F05D-6102-F150208.07.093 *81x02 D-8102-F05 D-8102-F15 02 08.57.014 *21x42D-2142-F05D-2142-F154298.57.084 *41x42 D-4142-F05 D-4142-F15 42 98.66.094 *61x42D-6142-F05D-6142-F154298.07.525 *81x42 D-8142-F05 D-8142-F15 42 98.57.055 *02x42D-0242-F05D-0242-F154298.08.095 ORDERS FAX 800-807-2214 SERIES 306 UNITED BRAND FITTINGS ANSI B16.1 Class 125STANDARD COMPANION FLANGE (Cast Iron) ANSI B16.1 Class 125 Larger sizes thru 24” available upon request. REDUCING COMPANION FLANGE (Cast Iron) 8 BC SERIES 316 BC Larger sizes thru 24” available upon request. lanimoN eziS .oNtcudorPCBOQ Y seloHtloB .tgW .oNeziS 1 5240-001-603 21.3 4/14 61/7 61/11 4 26.0 57.1 4/113640-521-60305.38/542/161/31426.000.2 2/11 0050-051-603 88.3 5 61/9 8/7 4 26.0 52.2 20060-002-60357.468/51457.000.4 2/12 0070-052-603 05.5 7 61/11 8/11 4 57.0 00.6 30570-003-60300.62/174/361/31457.036.7 2/13 0580-053-603 00.7 2/18 61/31 4/11 8 57.0 05.9 40090-004-60305.79 61/5161/51857.057.11 5 0001-005-603 05.8 01 61/51 61/71 8 88.0 00.41 60011-006-60305.9111 61/91888.005.61 8 0531-008-603 57.11 2/131 8/11 4/31 8 88.0 00.62 010061-0001-60352.416161/3161//5112100.100.83 21 0091-0021-603 00.71 91 4/11 61/32 21 00.1 00.15 eziSlanimoN .oNtcudorP daerhT eziS CBOQY seloHtloB thgieW .D.OxepiPepiPx.glF.oNeziS 5x11x2/11 0050-001-613 1 88.3 5 61/9 61/11 4 26.0 57.2 5x4/114/11x2/11 0050-521-613 4/11 61/31 05.2 6x11x20060-001-6131 57.468/5 61/11 457.0 00.5 6x4/114/11x20060-521-6134/1161/3157.4 6x2/112/11x20060-051-6132/118/705.4 7x2/112/11x2/12 0070-051-613 2/11 05.5 7 61/11 8/7 4 57.0 00.7 7x22x2/12 0070-002-613 2 1 57.6 2/17x11x30570-001-6131 00.62/174/3 61/31 457.0 00.9 2/17x2/112/11x30570-051-6132/118/757.8 2/17x22x30570-002-6132 1 05.8 2/17x2/122/12x30570-052-6132/128/1100.8 9x2/112/11x4 0090-051-613 2/11 05.7 9 61/51 1 8 57.0 57.41 9x22x4 0090-002-613 2 1 00.41 9x2/122/12x4 0090-052-613 2/12 8/11 05.31 9x33x4 0090-003-613 3 61/31 57.21 01x23x50001-003-613305.80161/51 61/31 888.0 00.71 01x44x50001-004-6134 61/5100.61 11x2/112/11x6 0011-051-613 2/11 05.9 11 1 61/11 8 88.0 00.72 11x22x6 0011-002-613 2 61/11 00.62 11x2/122/12x6 0011-052-613 2/12 8/11 00.52 11x33x6 0011-003-613 3 61/31 00.32 11x44x6 0011-004-613 4 61/51 00.12 11x55x6 0011-005-613 5 61/71 00.91 2/131x22x80531-002-6132 57.112/1318/11 61/31 888.0 00.44 2/131x33x80531-003-6133 61/3100.04 2/131x44x80531-004-6134 61/5100.73 2/131x55x80531-005-6135 61/7100.43 2/131x66x80531-006-6136 61/9100.13 61x22x010061-002-613 2 52.41 61 61/31 61/511 21 00.1 00.16 61x66x010061-006-613 6 61/511 00.35 61x88x010061-008-613 8 61/511 00.05 91x22x210091-002-6132 00.71914/11 61/32 2100.1 00.48 91x88x210091-008-6138 61/3200.18 91x0101x210091-0001-6130161/3200.27 ORDERS FAX 800-807-2214 UNITED BRAND FITTINGS ANSI B16.1 Class 125 ANSI B16.5 Class 150REDI-FLANGE No W el di n g! No Thr e a di n g! STANDARDS: Ductile Iron - ASTM A536 Grade 65-45-12. Drilling to ANSI B16.1 - 125 lb. ANSI B16.5 - 150 lb. SET SCREW: AISI steel. Tensile 160,000 psi minimum. GASKET: SBR (BUNA-N). HYDROSTATIC TEST PRESSURE: MODEL - RFC-2 - 125 lb./150 lb. 2 in. - 8 in. 600 psi 10 in. - 12 in. 525 psi MODEL - RFC-4 - 125 lb./150 lb. 3 in. - 12 in. 750 psi 14 in. - 24 in. 300 psi The Redi-Flange™ joins valves, fit- tings and equipment with integral flanged ends to plain end pipe, with- out the need of pipe end prepara- tion. Absolutely no threading, weld- ing, or grooving is necessary. The working principle of the Redi- Flange™ is relatively simple. Slide the flange over plain end pipe and follow it with a standard mechani- cal joint gasket. When the Redi- Flange™ is brought to mate against an existing flange, and the flange bolts are tightened, a compression type seal is created against the mat- ing flange and pipe surface. End restraint is provided when the set screws are tightened. ™ 9 .moN epiP eziS .oNtraP epiP.I.D .D.O D-2-CFR epiPleetS .D.O S-2-CFR egnalF .D.O tloB elcriC tloB eloH .aiD swercSteS .tgW .xorppA .oNeziS 2 102-CFR 83.2 05.2 6 4/34 4/3 2 1x2/1 5.3 2/12202-CFR-88.272/154/34 1x2/14 3 302-CFR 69.3 05.3 2/17 6 4/3 4 1x2/1 5 4402-CFR08.405.492/174/34 1x2/18 5 502-CFR -65.5 01 2/18 8/7 8 1x2/1 9 6602-CFR09.6526.6112/198/78 1x2/101 8 802-CFR 50.9 526.8 2/131 4/311 8/7 8 4/11x8/5 71 01012-CFR01.1157.01614/1411214/11x8/522 21 212-CFR 02.31 57.21 91 71 1 21 4/11x8/5 13 .moN epiP eziS .oNtraP epiP.I.D .D.O D-4-CFR epiPleetS .D.O S-4-CFR egnalF .D.O tloB elcriC yloB eloH .aiD swercSteS .tgW .xorppA .oNeziS 3 304-CFR 69.3 05.3 2/17 6 4/3 4 1x2/1 8 4404-CFR08.405.492/174/34 1x2/111 6 604-CFR 09.6 526.6 11 2/19 8/7 8 4/11x8/5 41 8804-CFR50.9526.82/1314/3118/78 4/11x8/512 01 014-CFR 01.11 57.01 61 4/141 1 21 4/11x8/5 83 21214-CFR02.3157.2191711214/11x8/565 41 414-CFR 03.51 AN 12 4/381 8/11 21 4/11x8/5 07 61614-CFR04.71AN2/1324/1128/11614/11x8/597 81 814-CFR 05.91 AN 52 4/322 4/11 61 2x4/3 09 02024-CFR06.12AN2/172524/11022x4/3541 42 424-CFR 08.52 AN 23 2/192 8/31 02 2x4/3 571 ORDERS FAX 800-807-2214 Mates with ANSI Class 125/150 flange drillings 10 UNITED BRAND FITTINGS COMPACT FLANGE REDUCER Class 125/150 Flanges Material: Ductile Iron ASTM A536 or ASTM A36 Steel Small End (Studs)T Large End (Studs) o.d.b.c.i.d.I.D.B.C.O.D. TYPE A Small End (Studs) T Large End (Studs) o.d.b.c.i.d.I.D.B.C.O.D. TYPE B egnalF seziS .oNtraP dnEegraLdnEllamS TepyT sdutSdnEegraLsdutSdnEllamS .D.I.D.O.C.B.d.i.d.o.c.b.ytQeziS.ytQeziS 2/11x2 001-011-047 00.2 00.6 57.4 05.1 00.6 88.3 05.1 A 4 2/12x8/5 4 2/12x2/1 2/11x2/12001-021-04705.200.705.505.100.688.305.1A4 2/12x8/54 2/12x2/1 2x2/12 011-021-047 05.2 00.7 05.5 00.2 00.6 57.4 05.1 A 4 2/12x8/5 4 2/12x8/5 2/11x3001-031-04700.305.700.605.100.688.305.1A4 2/12x8/54 2/12x2/1 2x3 011-031-047 00.3 05.7 00.6 00.2 00.6 57.4 05.1 A 4 3x8/5 4 3x8/5 2/12x3021-031-04700.305.700.605.200.705.505.1A4 2/12x8/54 2/12x8/5 2x4 011-041-047 00.4 00.9 05.7 00.2 00.6 57.4 05.1 A 8 2/12x8/5 4 2/12x8/5 2/12x4021-041-04700.400.905.705.200.705.505.1A8 2/12x8/54 2/12x8/5 3x4 031-041-047 00.4 00.9 05.7 00.3 05.7 00.6 05.1 A 8 2/12x8/5 4 2/12x8/5 2/12x6021-061-09700.600.1105.905.200.705.505.1B- - 8 2/13X4/3 3x6 031-061-097 00.6 00.11 05.9 00.3 05.7 00.6 05.1 B --8 2/13X4/3 4x6041-061-04700.600.1105.900.400.905.700.2A8 3x4/38 2/12x8/5 5x6 051-061-047 00.6 00.11 05.9 00.5 00.01 05.8 00.2 A 8 3x4/3 8 3x4/3 4x8041-081-09700.805.3157.1100.400.905.700.2B- - 8 2/13x4/3 5x8 051-081-047 00.8 05.31 57.11 00.5 00.01 05.8 00.2 A 8 2/13x4/3 8 3x4/3 6x8061-081-04700.805.3157.1100.600.1105.900.2A8 2/13x4/383x4/3 2x01 011-002-097 00.01 00.61 52.41 00.2 00.6 57.4 05.1 B --4 2/12x8/5 4x01041-002-09700.0100.6152.4100.400.905.700.2B- - 214x8/7 5x01 051-002-097 00.01 00.61 52.41 00.5 00.01 05.8 00.2 B --21 4x8/7 6x01061-002-04700.0100.6152.4100.600.1105.900.2A214/33x8/783x4/3 8x01 081-002-047 00.01 00.61 52.41 00.8 05.31 57.11 00.2 A 21 4/33x8/7 8 2/13x4/3 4x21041-022-09700.2100.9100.7100.400.905.700.2B- - 214x8/7 6x21 061-022-097 00.21 00.91 00.71 00.6 00.11 05.9 00.2 B --21 4x8/7 8x21081-022-04700.2100.9100.7100.805.3157.1100.2A214/33x8/78 2/13x4/3 01x21 002-022-047 00.21 00.91 00.71 00.01 00.61 52.41 00.2 A 21 4/33x8/7 21 4/33x8/7 6x41061-042-09700.4100.1257.8100.600.1105.905.2B- - 212/14x1 8x41 081-042-097 00.41 00.12 57.81 00.8 05.31 57.11 05.2 B --21 2/14x1 01x41002-042-04700.4100.1257.8100.0100.6152.4105.2A214x1212/13x8/7 21x41 022-042-047 00.41 00.12 57.81 00.21 00.91 00.71 05.2 A 21 4x1 21 2/13x8/7 6x61061-062-09700.6105.3252.1200.300.1105.905.2B- - 612/14x1 8x61 081-062-097 00.61 05.32 52.12 00.8 05.31 57.11 05.2 B --61 2/14x1 01x61002-062-09700.6105.3252.1200.0100.6152.4105.2B- - 614x1 21x61 022-062-047 00.61 05.32 52.12 00.21 00.91 00.71 05.2 A 61 4x1 21 2/13x8/7 41x61042-062-04700.6105.3252.1200.4100.1257.8105.2A614x1214x1 ORDERS FAX 800-807-2214 11 UNITED BRAND FITTINGS ANSI B16.1 Class 125 SERIES 60 (1”-10”) BLIND FLANGES SERIES 60 (12”) ANSI B16.1 Class 125FLANGE CONVERTERS Class 125/150 Class 250/300 *14”~24” are made from high strength ductile iron to ANSI A21.10, AWWA C110, WWP 250. eziS.oNtraPOQVthgieW 1 G-0010-F06 52.4 44.83.2 4/11G-5210-F0626.405.44.52.2 2/11 G-0510-F06 00.5 65.05.57.3 2G-0020-F0600.626.26.5 2/12 G-0520-F06 00.7 86.26.7 3G-0030-F0605.757.96.9 2/13 G-0530-F06 05.8 18.57.41 4G-0040-F0600.949.88.61 5 G-0050-F06 00.01 49.88.81 6G-0060-F0600.1100.149.52 8 G-0080-F06 05.31 21.1 60.1 24 01G-0001-F0600.6191.121.126 21 G-0021-F06 00.91 52.1 18.58 *41D-0041-F0600.1283.188.021 *61 D-0061-F06 05.32 44.1 00.1 541 *81D-0081-F0600.5265.160.1581 *02 D-0002-F06 05.72 96.1 21.1 542 *42D-0042-F0600.2388.152.1073 .oNtraP 051/521SSALC 003/052SSALC thgieW egnalF .D.I/eziS .d.o.c.b fo.oN tloB seloH tloBdutS eziS W.C.B.D.OAT fo.oN tloB seloH tloBdutS eziS 041-048 4 9 5.7 8 2/12x8/5 49.6 88.7 01 60.0 2 8 2/13x4/3 82 051-0485015.88 3x4/313.852.91160.028 2/13x4/323 061-048 6 11 5.9 8 3x4/3 96.9 26.01 5.21 60.0 2 21 2/13x4/3 24 081-04885.3157.118 2/13x4/349.11315160.04/12214x8/766 002-048 01 61 52.41 21 2/13x8/7 60.41 52.51 5.71 60.0 4/32 61 2/14x1 001 022-048219171212/13x8/744.6157.715.0260.04/32615x8/11061 ORDERS FAX 800-807-2214 FLAT FLANGE GASKET UNITED BRAND FITTINGS ANSI B16.1 Class 125SEAL-TITE FLANGE GASKET Ring Type Flange Gasket O.D. A B I.D. Material: Red Rubber Non-Asbestos Serrat e d F a c e! Full Face Material: Buna-N Ring Type Full Face Gaskets Size: 8” Qty: 25 Linx, Ltd. Middletown, RI USA Low T or q u e! Bolt Holes Full Face Flange Gasket O.D. B.C. BA I.D. 12 lanimoN .oNtraP )ecaFlluF( .oNtraP )gniR(DI DO )ecaFlluF( DO )gniR(AB CB )ecaFlluF( xoB ytitnauQ )ecaFlluF( xoB ytitnauQ )gniR(eziS 2 051-050-GFF 001-050-GR 51.2 00.6 09.3 23/5 8/1 57.4 52 52 2/12571-560-GFF021-560-GR37.200.707.423/58/105.55252 3 881-080-GFF 231-080-GR 02.3 05.7 51.5 23/5 8/1 00.6 52 52 4012-001-GFF261-001-GR89.300.903.623/58/105.75252 5 052-521-GFF 491-521-GR 70.5 00.01 06.7 23/5 8/1 05.8 52 52 6572-051-GFF812-051-GR10.600.1105.823/58/105.95252 8 043-002-GFF 272-002-GR 11.8 05.31 06.01 23/5 8/1 57.11 52 52 01004-052-GFF823-052-GR60.0100.6108.2123/58/152.415252 21 574-003-GFF 873-003-GR 90.21 00.91 57.41 23/5 8/1 00.71 52 52 41525-053-GFF544-053-GR21.4100.1251.7123/58/157.810252 61 885-004-GFF 015-004-GR 91.61 05.32 09.91 23/5 8/1 52.12 02 52 81526-054-GFF245-054-GR52.8100.5251.1223/58/157.220202 02 886-005-GFF 606-005-GR 82.02 05.72 06.32 23/5 8/1 00.52 02 02 42008-006-GFF717-006-GR43.4200.2359.7223/58/105.920202 lanimoN .oNtraP )ecaFlluF( .oNtraP )gniR( DO )ecaFlluF( DO )gniR(ssenkcihT tloB elcriC )ecaFlluF( xoB ytitnauQ )ecaFlluF( xoB ytitnauQ )gniR(eziS 2 051-050-FFF 001-050-GRF 00.6 09.3 8/1 57.4 52 52 2/12571-560-FFF021-560-GRF00.707.48/105.55252 3 881-080-FFF 231-080-GRF 05.7 51.5 8/1 00.6 52 52 4012-001-FFF261-001-GRF00.903.68/105.75252 5 052-521-FFF 491-521-GRF 00.01 06.7 8/1 05.8 52 52 6572-051-FFF812-051-GRF00.1105.88/105.95252 8 043-002-FFF 272-002-GRF 05.31 06.01 8/1 57.11 52 52 01004-052-FFF823-052-GRF00.6108.218/152.415252 21 574-003-FFF 873-003-GRF 00.91 57.41 8/1 00.71 52 52 41525-053-FFF544-053-GRF00.1251.718/157.810252 61 885-004-FFF 015-004-GRF 05.32 09.91 8/1 52.12 02 52 81526-054-FFF245-054-GRF00.5251.128/157.220202 02 886-005-FFF 606-005-GRF 05.72 06.32 8/1 00.52 02 02 42008-006-FFF717-006-GRF00.2359.728/105.920202 ORDERS FAX 800-807-2214 ANSI B16.1 Class 125 ANSI B16.5 Class 250 Available-plain, zinc plated, hot dipped galvanized, and type 304 stainless steel. Heavy Hex Head Bolts (ANSI B18.2.1/ASTM-A307 Grade B) Heavy Hex Nuts (ANSI B18.2.2/ASTM-A563 Grade A) FLANGE ACCESSORY PACKS Zinc plated bolts and nuts. 13 UNITED BRAND FITTINGS Bolt and Nut Packs for Class 125/150 Flanges .oNtraP ssalC 051/521 egnalF eziS tloB retemaiD htgneLdna fo.oN repstloB gaByloP xoBretsaM fo.ytQ( )steS xoBretsaM thgieW ).sbL( 30ZBF 2 2/12x8/5 42/12 23 05 3 40ZBF43x8/586155 80ZBF 5 6 2/13x4/3 8 8 05 8 21ZBF 01 4x8/7214 5521 41ZBF 41 2/14x1 21 2 04 61ZBF612/14x1612 25 81ZBF 81 5x8/11 61 1 73 02ZBF025x8/1102144 42ZBF 42 2/15x4/11 02 1 07 051/521ssalC egnalF ecaFlluF"8/1 etiT-laeS )detarreS( epyTgniR"8/1 etiT-laeS )detarreS( ecaFlluF"8/1 rebbuRdeR epyTgniR"8/1 rebbuRdeR ecaFlluF"8/1 sotsebsA-noN epyTgniR"8/1 sotsebsA-noNeziS 2 *-020-RBF *-020-PBR *-020-PRF *-020-PRR *-020-PNF *-020-PNR 2/12-520-020-RBF-520-020-PBR-520-020-PRF-520-020-PRR-520-020-PNF-520-020-PNR 3 -030-RBF -030-PBR -030-PRF -030-PRR -030-PNF -030-PNR 4-040-RBF-040-PBR-040-PRF-040-PRR-040-PNF-040-PNR 5 -050-RBF -050-PBR -050-PRF -050-PRR -050-PNF -050-PNR 6-060-RBF-060-PBR-060-PRF-060-PRR-060-PNF-060-PNR 8 -080-RBF -080-PBR -080-PRF -080-PRR -080-PNF -080-PNR 01-001-RBF-001-PBR-001-PRF-001-PRR-001-PNF-001-PNR 21 -021-RBF -021-PBR -021-PRF -021-PRR -021-PNF -021-PNR 41-041-RBF-041-PBR-041-PRF-041-PRR-041-PNF-041-PNR 61 -061-RBF -061-PBR -061-PRF -061-PRR -061-PNF -061-PNR 81-081-RBF-081-PBR-081-PRF-081-PRR-081-PNF-081-PNR 02 -002-RBF -002-PBR -002-PRF -002-PRR -002-PNF -002-PNR 42-042-RBF-042-PBR-042-PRF-042-PRR-042-PNF-042-PNR ORDERS FAX 800-807-2214 FLANGE DETAILS - Class 250 All dimensional data in inches and lbs. ELBOWS 90° REDUCING ELBOW T OD RF 1/16” TEES REDUCING TEES UNITED BRAND FITTINGS ANSI B16.1 Class 250 14 ANSI B16.1 Class 250 ANSI B16.1 Class 250 ANSI B16.1 Class 250 ANSI B16.1 Class 250 eziS.oNtraPAthgieW 4x6 G-4060-F001 2/18 59 6x8G-6080-F00101161 8x01 8001-F001 2/111 042 eziS.oNtraPAthgieW 4 G-4040-F002 7 89 6G-6060-F0022/18481 8 G-8080-F002 01 082 01G-0101-F0022/111534 21 G-2121-F002 31 995 eziS.oNtraPAthgieW 4x6x6 G-406060-F062 2/18 051 6x8x8G-608080-F06201642 eziSDOT FRCB tloB eloH .aiD &.aiDtloB htgneL fo.oN stloB 3 4/18 61/31 61/115 8/56 8/7 2/13x4/3 8 4014/3161/5168/778/74/33x4/38 5 11 8/71 61/58 4/19 8/7 4x4/3 8 62/12161/51161/1198/5018/74x4/321 8 51 61/32 61/5111 31 1 4/14x8/7 21 012/1718/3261/1414/1518/114/15x161 21 2/102 61/92 61/761 4/371 4/11 2/15x8/11 61 eziS 09o woblE54owoblE .oNtraPA.tgW.oNtraPA.tgW 3 G-3030-F001 6 04 G-3030-F011 2/13 53 4G-4040-F001766G-4040-F0112/1406 6 G-6060-F001 2/18 421 G-6060-F011 2/15 301 8G-8080-F00101291G-8080-F0116851 01 G-0101-F001 2/111 113 G-0101-F011 7 742 21G-2121-F00131034G-2121-F0118553 ORDERS FAX 800-807-2214 UNITED BRAND FITTINGS ANSI B16.1 Class 250REDUCERS CROSSES BLIND FLANGES B C D E Dished faces for use with 10” and 12” extra heavy Blind Flanges. E D B C THREADED FLANGES B D E F C 15 ANSI B16.1 Class 250 ANSI B16.1 Class 250 ANSI B16.1 Class 250 A 1/16” 1/16” 1/16” eziS.oNtraPAthgieW 4 G-4040-F053 7 931 6G-6060-F0532/18822 8 G-8080-F053 01 073 lanimoN epiP eziS egnalF eziS .oNtraPCBDEthgieW 3 4/18x3 G-3030-F006 61/31 4/18 61/115 8/56 41 401x4G-4040-F0064/110161/5168/7752 6 2/121x6 G-6060-F006 61/71 2/121 61/119 8/501 34 851x8G-8080-F0068/515161/51113196 01 2/171x01 G-0101-F006 8/71 2/171 61/141 4/151 001 212/102x21G-2121-F00622/10261/7614/371841 lanimoN epiP eziS egnalF eziS .oNtraPCBDEFthgieW 3 4/18x3 G-3030-F067 8/11 4/18 61/115 8/56 61/111 21 401x4G-4040-F0674/110161/5168/774/3112 6 2/121x6 G-6060-F067 61/71 2/121 61/119 8/501 61/511 33 851x8G-8080-F0678/515161/51113161/3215 01 2/171x01 G-0101-F067 8/71 2/171 61/141 4/151 8/32 77 212/102x21G-2121-F06722/10261/7614/37161/92301 eziS.oNtraPAthgieW 3x4 G-3040-F005 7 04 4x6G-4060-F005977 5x6 G-5060-F005 9 58 6x8G-6080-F00511241 8x01 G-8001-F005 21 691 Napac, Inc. 229 Southbridge Street Worcester, Massachusetts 01608 USA Tel.: 800-807-2215 Fax: 800-807-2214 NF701 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: For Fire Protection & Other Low Pressure Piping Systems Welded Outlet Fittings SPF-8.14 SPF Welded Outlet Fittings offer the user a high strength, low cost forged threaded and grooved line of fittings specifically designed and manufactured to be installed on proprietary thin wall flow pipe, Schedule 5, 10, and 40 standard wall pipes. SPF Welded Outlets are forged steel welding outlet fittings. The material used in manufacture meets the chemical and physical requirements of ASTM A 53. SPF Welded Outlet Fittings employ a low weld volume design to provide either a partial or full penetration weld employing a single pass with minimum burn-through and pipe distortion. Threads comply with ANSI B1.20.1. The SPF Welded Outlets are UL Listed and FM Approved for use conforming to the requirements of NFPA 13. SPF Welded Outlet Fittings are rated for 300 psi when used in fire sprinkler system applications. SPF WELDED OUTLET FITTINGS Outlet Model Outlet Pipe Size Header Pipe Size Rated Pressure In.In.psig MTM-40 1⁄2, 3⁄4, 1 1⁄2 - 8 (Sch.10, 40) 30011⁄4, 11⁄2, 2, 21⁄2, 3, 4 1⁄2 - 4 (Sch. 5, DynaFlow) 2 4, 6 (EZ-Flow) GR-40 1 - 8 11⁄4 - 8 (Sch.10, 40)30021⁄2 - 8 21⁄2 - 8 (Sch. 5, DynaFlow) For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. 1) Size-on size (i.e. 2 x 2) SPF Welded Outlet Fittings are not FM Approved. 2) FM rated working pressure when welded on Sch. 5 or lightwall pipe is 175 psi. 3) Refer to the UL and FM websites for the most current pressure ratings. Welded Outlet Fittings SPF-8.14 SPF Welded Outlets are designed and Manufac- tured to reduce the amount of weld required to install the Tee-Lets on thin wall or proprietary flow pipe. Typically only one weld-pass completes the installation. SPF Welded Outlets install with less weld volume than any other brand of welding outlet fittings for fire sprinkler applications. To accomplish this: • The contoured end of the fittings employs a reduced outside diameter. Two major advantages are immediately apparent: • The thinner wall on the contoured end permits welding temperatures to be matched to the thickness of the branch line or main thereby insuring complete penetration without cold welds, weld roll-off, burn- through or excessive distortion. • On smaller sizes a heavier section is maintained on the threaded end of the fitting. This protects the threads from damage during shipping and handling prior to installation as well as from weld distortion. • Each outlet size 11⁄2" and larger, whether female threaded, cut grooved or beveled requires the same hole size in the header pipe. This simplifies the installation process. GENERAL SPECIFICATIONS • Welded outlet fittings are manufactured from highly weldable steel which conforms to the chemical and physical requirements of ASTM A-53, Grades A or B, Type E. Ease of installation is assured when automatic welding equipment is used to install SPF Welded Outlets. • Threads are cut in accordance with the requirements of ANSI B1.20.1, national standard for tapered pipe threads. • SPF Welded Outlets threaded and grooved welding outlet fittings are UL/ULC Listed and FM Approved for use in the fire sprinkler systems installed in accordance with the requirements of NFPA 13. They are rated for 300 PSI operation in fire sprinkler systems, and higher pressures in other non-critical piping systems. • SPF Welded Outlets are offered in a wide variety of header sizes. The consolidated header sizes shown in the following charts allow the fittings to be installed on more than one header size, permitting the first size listed to fit the header perfectly, while a small gap along the longitudinal center line of the header will appear for the second size listed. • SPF Welded Outlets are identified by a lot number that provides full traceability. FOR YOUR PIPING SYSTEMS SPECIFY SPF WELDED OUTLETS Branch Outlet Fittings shall be SPF Welded Outlets, Lightweight forged steel, employing low weld volume profile to provide for full penetration welds with minimum burn through and pipe distortion on Schedule 5 thru 10, proprietary thin wall, and standard wall pipe. Threads are to be ANSI B1.20.1 and the bore of the fittings calculated to improve flow. Welding outlets to be UL Listed, FM Approved for use conforming to NFPA 13, and pressure rated for 300 PSI maximum. Welded Outlet Fittings SPF-8.14 SPF WELDED OUTLETS - MTM-40 Part Number Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter D Make Up M Weight Each NPT In./mm In./mm In./mm In./mm In./mm Lbs./kg 0870001005 1⁄2 x 13 x 11⁄4 - 11⁄2 1.063 0.700 0.500 0.171 32 - 40 27.0 17.8 12.7 0.08 0870001013 11⁄2 - 2 1.063 0.700 0.500 0.171 40 - 50 27.0 17.8 12.7 0.08 0870001021 2 - 21⁄2 1.063 0.700 0.500 0.171 50 - 65 27.0 17.8 12.7 0.08 0870001039 21⁄2 - 8 1.063 0.700 0.500 0.169 65 - 200 27.0 17.8 12.7 0.08 0870001054 3⁄4 x 19 x 11⁄4 - 11⁄2 1.125 0.900 0.500 0.260 32 - 40 28.6 22.9 12.7 0.12 0870001062 11⁄2 - 2 1.125 0.900 0.500 0.260 40 - 50 28.6 22.9 12.7 0.12 0870001070 2 - 21⁄2 1.125 0.900 0.500 0.260 50 - 65 28.6 22.9 12.7 0.12 0870001088 21⁄2 - 8 1.125 0.900 0.500 0.256 65 - 200 28.6 22.9 12.7 0.12 0870001096 1 x 25 x 11⁄4 - 11⁄2 1.250 1.145 0.500 0.331 32 - 40 31.8 29.1 12.7 0.15 0870001104 11⁄2 - 2 1.250 1.145 0.500 0.331 40 - 50 31.8 29.1 12.7 0.15 0870001112 2 - 21⁄2 1.250 1.145 0.500 0.320 50 - 65 31.8 29.1 12.7 0.15 0870001120 21⁄2 - 3 1.250 1.145 0.500 0.314 65 - 80 31.8 29.1 12.7 0.14 0870001138 3 - 4 1.250 1.145 0.500 0.309 80 - 100 31.8 29.1 12.7 0.14 0870001146 5 - 8 1.250 1.145 0.500 0.291 125 - 200 31.8 29.1 12.7 0.13 0870001153 11⁄4 x 32 x 11⁄4 - 11⁄2 1.375 1.490 0.500 0.432 32 - 40 34.9 37.8 12.7 .019 0870001161 11⁄2 - 2 1.375 1.490 0.500 0.421 40 - 50 34.9 37.8 12.7 .019 0870001179 2 - 21⁄2 1.375 1.490 0.500 0.421 50 - 65 34.9 37.8 12.7 .019 0870001187 21⁄2 - 3 1.375 1.490 0.500 0.411 65 - 80 34.9 37.8 12.7 .019 0870001195 3 - 4 1.375 1.490 0.500 0.389 80 - 100 34.9 37.8 12.7 .018 0870001203 5 - 8 1.375 1.490 0.500 0.389 125 - 200 34.9 37.8 12.7 .018 0870001211 11⁄2 x 40 x 11⁄2 1.625 1.610 0.875 0.477 40 41.3 40.9 22.2 .022 0870001229 2 1.625 1.610 0.875 0.477 50 41.3 40.9 22.2 .022 0870001237 21⁄2 1.625 1.610 0.875 0.477 65 41.3 40.9 22.2 .022 0870001245 3 - 4 1.625 1.610 0.875 0.477 80 - 100 41.3 40.9 22.2 .022 0870001252 4 1.625 1.610 0.875 0.477 100 41.3 40.9 22.2 .022 0870001260 5 - 8 1.625 1.610 0.875 0.477 125 - 200 41.3 40.9 22.2 .022 SPF WELDED OUTLETS - MTM-40 PartNumber Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter D Make Up M Weight Each NPT/BSPT In./mm In./mm In./mm In./mm In./mm Lbs./kg 0870001278 2 x 50 x 2 1.750 2.067 0.875 0.857 50 44.5 52.5 22.2 0.38 0870001286 21⁄2 1.750 2.067 0.875 0.829 65 44.5 52.5 22.2 0.38 0870001294 3 1.750 2.067 0.875 0.829 80 44.5 52.5 22.2 0.39 0870001302 4 1.750 2.067 0.875 0.800 100 44.5 52.5 22.2 0.36 0870001310 6 1.750 2.067 0.875 0.743 150 44.5 52.5 22.2 0.34 0870001328 8 1.750 2.067 0.875 0.743 200 44.5 52.5 22.2 0.34 For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. D C M A B MTM-40 Female Thread Welded Outlet Fittings SPF-8.14 SPF WELDED OUTLETS - GR-40 (Nominal Sizes 11/4" thru 2") GR-40Cut Groove Std. Wt. Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter D Outside Diameter E Wall Thickness F NPT In./mm In./mm In./mm In./mm In./mm In./mm 0870004009 11⁄4 x 32 x 11⁄4 3 1.368 1.660 0.140 32 80 34.7 42.2 3.6 0870004025 11⁄2 3 1.368 1.660 0.140 40 80 34.7 42.2 3.6 0870004041 2 - 21⁄2 3 1.368 1.660 0.140 50 - 65 80 34.7 42.2 3.6 0870004066 3 - 4 3 1.368 1.660 0.140 80 - 100 80 34.7 42.2 3.6 0870004082 5 - 8 3 1.368 1.660 0.140 125 - 200 80 34.7 42.2 3.6 0870004108 11⁄2 x 40 x 11⁄2 3 1.610 1.900 0.145 40 80 40.9 48.3 3.7 0870004124 2 3 1.610 1.900 0.145 50 80 40.9 48.3 3.7 0870004140 21⁄2 3 1.610 1.900 0.145 65 80 40.9 48.3 3.7 0870004165 3 - 4 3 1.610 1.900 0.145 80 - 100 80 40.9 48.3 3.7 0870004181 5 - 8 3 1.610 1.900 0.145 125 - 200 80 40.9 48.3 3.7 0870004207 2 x 50 x 2 3 2.067 2.375 0.154 50 80 52.5 60.3 3.9 0870004223 21⁄2 3 2.067 2.375 0.154 65 80 52.5 60.3 3.9 0870004249 3 3 2.067 2.375 0.154 80 80 52.5 60.3 3.9 0870004264 4 3 2.067 2.375 0.154 100 80 52.5 60.3 3.9 0870004280 6 3 2.067 2.375 0.154 150 80 52.5 60.3 3.9 0870004306 8 3 2.067 2.375 0.154 200 80 52.5 60.3 3.9 GR-40 Cut Groove Standard Weight E C B A F D Note: Welded Outlets are manufactured to fit size-on-size, that is the contoured shape on a given Welded Outlet is made to fit perfectly on the first listed header size. If installed on the second header size marked on the fitting, a slight gap of approximately 1⁄32" will appear along the longitudinal centerline of the header. For example, a 1" x 2 - 21⁄2" Welded Outlet, is a 1" outlet fitting manufactured to fit perfectly on the 2" header size listed, while leaving a 1⁄32" gap along the longitudinal centerline of the 21⁄2" size. If a perfect fit is required for a 21⁄2" header pipe, then a 1" x 21⁄2 - 3" Welded Outlet would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. (Additional larger sizes on next page.) Welded Outlet Fittings SPF-8.14 SPF WELDED OUTLETS - GR-40 (Nominal Sizes 21/2" thru 8") GR-40 Cut Groove Std. Wt. Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter - D Outside Diameter E Wall Thickness - F Standard Weight Schedule 10 Standard Weight Schedule 10 NPT In./mm In./mm In./mm In./mm In./mm In./mm In./mm In./mm 0870004322 21⁄2 x 65 x 21⁄2 3 2.469 2.635 2.875 0.203 0.120 65 80 62.7 67.0 76.2 5.0 3.0 0870004348 4 3 2.469 2.635 2.875 0.203 0.120 100 80 62.7 67.0 76.2 5.0 3.0 0870004363 6 3 2.469 2.635 2.875 0.203 0.120 175 80 62.7 67.0 76.2 5.0 3.0 0870004389 8 3 2.469 2.635 2.875 0.203 0.120 200 80 62.7 67.0 76.2 5.0 3.0 0870004405 3 x 80 x 3 3 3.068 3.260 3.500 0.216 0.120 80 80 78.0 83.0 88.0 5.0 3.0 0870004421 4 3 3.068 3.260 3.500 0.216 0.120 100 80 78.0 83.0 88.0 5.0 3.0 0870004447 6 3 3.068 3.260 3.500 0.216 0.120 150 80 78.0 83.0 88.0 5.0 3.0 0870004462 8 3 3.068 3.260 3.500 0.216 0.120 200 80 78.0 83.0 88.0 5.0 3.0 0870004504 4 x 100 x 4 4 4.026 4.260 4.500 0.237 0.120 100 100 102.0 108.0 114.0 6.0 3.0 0870004520 6 4 4.026 4.260 4.500 0.237 0.120 150 100 102.0 108.0 114.0 6.0 3.0 0870004546 8 4 4.026 4.260 4.500 0.237 0.120 200 100 102.0 108.0 114.0 6.0 3.0 0870004603 6 x 150 x 6 4 6.065 6.357 6.625 0.280 0.134 150 100 155.0 161.5 168.3 7.1 3.0 0870004629 8 4 6.065 6.357 6.625 0.280 0.134 200 100 155.0 161.5 168.3 7.1 3.0 0870004702 8 x 8 4 7.981 8.329 8.625 0.322 0.148 200 x 200 100 203.0 212.0 213.0 8.0 3.0 Note: Welded Outlets are manufactured to fit size-on-size, that is the contoured shape on a given Welded Outlet is made to fit perfectly on the first listed header size. If installed on the second header size marked on the fitting, a slight gap of approximately 1⁄32" will appear along the longitudinal centerline of the header. For example, a 1" x 2 - 21⁄2" Welded Outlet, is a 1" outlet fitting manufactured to fit perfectly on the 2" header size listed, while leaving a 1⁄32" gap along the longitudinal centerline of the 21⁄2" size. If a perfect fit is required for a 21⁄2" header pipe, then a 1" x 21⁄2 - 3" Welded Outlet would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. GR-40 Cut Groove Standard Weight E C B A F D Welded Outlet Fittings SPF-8.14 Tapered hole matches pitch line of thread leaving a fully formed female thread. Pitch Line Welded Outlet Wrench Tight L3 Effective Thread L2 Hand Tight L1 Vanish Threads V Male Pipe Pitch Female Wrench Tight L3 Effective Thread L2 Vanish Threads V Male Pipe Standard tap drill leaves excess truncation on L3 threads. SPF NPT THREAD FORM STANDARD NPT THREAD FORM Welding Practice When measured with respect to linear inches of weld required for installation, SPF Welded Outlets require up to 15% less weld than competitive fittings. This reduces time and savings over time are substantial. The diameter of the contoured end of Welded Outlet has been reduced so that the wall thickness more nearly matches the header or branch line pipe wall thickness. There- fore, current and voltage settings required for welding are set to provide for adequate penetration without burn through and cold shutting. Also, weld volume required for installation is lower for SPF Welded Outlets than most other fittings. Typically, SPF Welded Outlets require one-weld pass for attachment. WELDING PRACTICE Outlet Size SPF WELDED OUTLETS COMPETITIVE FITTING WELD VOLUME*LINEAR WELDING WELD VOLUME* LINEAR WELDING In. (mm) Cross Sec. Area %less In.(mm)%less Cross Sec. Area %more In.(mm)%less 1" 0.051 sq. in. 12% 2.48 0% 0.058 sq. in. 12% 2.48 0% 25 32.9 sq mm 62.9 37.4 sq mm 62.9 11⁄4" 0.032" 48% 2.88 4% 0.063 48% 3.01 4% 32 20.6 73.1 40.6 76.4 11⁄2" 0.036" 40% 3.12 10% 0.060 40% 3.46 10% 40 23.2 79.2 38.7 87.8 2" 0.040" 62% 3.77 15% 0.106 62% 4.41 15% 50 25.8 95.7 68.3 112.0 .205" 2.650" 2" SPF Welded Outlet .065" .325" 2.820" 2" Competitive Fitting .180" Threading Practice SPF Welded Outlets thread form is consistent with Aeronautical National Form (ANPT) AS71051. The thread is fully formed over both the L-1 hand tight and L-3 wrench tight threads. NPT tapered threads are typically gauged only over the L-1 threads. This makes SPF Welded Outlets more forgiving of field cut threaded pipe that may only marginally conform to the specifi- cation. Fewer leaks translate into lower costs. Ease of Installation SPF Welded Outlets are designed to sit higher on the pipe, thereby requiring less weld and eliminating burn through. SPF Welded Outlets sit higher on the header or branch line pipe than competitive fittings. This allows the welding torch to remain in an optimum position for welding. In addition, 11/2" and larger female threaded and grooved welded outlets require the same hole size for installation. This results in fewer change overs when installed using automatic welders. NPT TAPERED PIPE THREADS Drop Nipple or Tee-Let Outlet Size L1 Hand Tight L3 Wrench Tight Total L1 - L3 Length L2 Effective Threads In./mm In./mm Threads In./mm Threads In./mm Threads In./mm Threads 1⁄2 0.320 4.48 0.214 3.00 0.534 7.48 0.534 7.4715 8.1 5.4 13.6 13.6 3⁄4 0.339 4.75 0.214 3.00 0.553 7.75 0.546 7.6420 8.6 5.4 14.0 13.9 1 0.400 4.60 0.261 3.00 0.661 7.60 0.683 7.8525 10.2 6.6 16.8 17.3 11⁄4 0.420 4.83 0.261 3.00 0.681 7.83 0.707 8.1332 10.7 6.6 17.3 18.0 11⁄2 0.420 4.83 0.261 3.00 0.697 7.83 0.724 8.3240 10.7 6.6 17.7 18.4 2 0.436 5.01 0.261 3.00 0.706 8.01 0.757 8.7050 11.1 6.6 17.9 19.2 21⁄2 0.682 5.46 0.250 2.00 0.932 7.46 1.138 9.1065 17.3 6.4 23.7 28.9 3 0.766 6.13 0.250 2.00 1.016 8.13 1.200 9.6080 19.5 6.4 25.8 30.5 4 0.844 6.75 0.250 2.00 1.094 8.75 1.300 10.40100 21.4 6.4 27.8 33.0 Welded Outlet Fittings SPF-8.14 RECOMMENDED OUTLET HOLE SIZES Welded OutletSize Type Recommended Hole Size In./mm In./mm 1⁄2 MTM-40 5⁄8 13 16 3⁄4 MTM-40 7⁄8 19 22 1 MTM-40 11⁄8 25 28 11⁄4 MTM-40 11⁄2 31 38 11⁄4 GR-40 13⁄8 31 35 11⁄2 MTM-40 or GR-40 15⁄8 38 41 2 MTM-40 or GR-40 2 50 50 21⁄2 GR-40 27⁄16 63 61 3 GR-40 3 75 75 4 GR-40 4 100 100 1⁄2, 3⁄4 & 1 Outlet 11⁄4 - 2 Outlet B ARecommended Installation Procedures SPF Welded Outlet Fittings are designed and manufactured to reduce the cost of installation from both the standpoint of labor required and energy consumed. In addition, by following the recommended installation procedures, many of the problems associated with installing welding outlet fittings on standard weight or light weight pipe are eliminated, including burn through and excessive shrinkage resulting in pipe distortion. Recommended Hole Sizes The hole cut in the branch or header pipe can be cut prior or subsequent to attachment of the Welded Outlets. One advantage of cutting the hole after welding is that the pipe is left intact during welding, thereby, reducing shrinkage and possible distortion. If holes are cut prior to welding, as some codes require, then the following hole sizes are recommended. Recommended Welding Procedures SPF Welded Outlet Fittings are designed to be installed on standard weight or light weight pipe with one weld pass on sizes through 4”. Moreover, the wall thickness at the weld end of the fitting approximately matches standard weight pipe. Accordingly, heat settings can be made to optimize penetration on both the fitting and the pipe which it is being welded. Aside from reducing the likelihood of burn through and distortion resulting from excessive heat, the amount of weld required for adequate penetration is significantly reduced. As a general rule, the weld should be only as hot as required to allow the weld to penetrate the materials being welded while concomitantly allowing gases developed in the welding process to escape. Every effort must be made to avoid welding too hot or overheating both the pipe and the Welded Outlets. Excessive heat may cause the wrench tight threads (those in the bottom of the Welded Outlets near the weld zone) to distort while also causing the branch pipe to bend. It should be noted that SPF Welded Outlet Fittings have been subjected to exhaustive testing and evaluation, and only negligibly distort when subjected to excessive heat. The threads, on the other hand, may not return to their gauged form after cooling if excessive heat causes them to expand. The following is intended only as a guide, and assumes that the welding equipment is properly calibrated and functioning normally and the operator is qualified. RECOMMENDED AMOUNT OF WELD Outlet Size A B In./mm In./mm In./mm 1 1⁄4 3⁄16 25 7 5 11⁄4 1⁄4 3⁄16 31 7 5 11⁄2 5⁄16 1⁄4 38 8 7 2 5⁄16 1⁄4 50 8 7 21⁄2 5⁄16 1⁄4 63 8 7 3 3⁄8 5⁄16 75 10 8 4 3⁄8 5⁄16 100 10 8 Note: Please refer to www.anvilintl.com or latest catalog for recommended hole size and welding practice. Holes may be cut employing mechanical means – including hole sawing, mechanical flame cutting (oxy-acetylene or propane), and air plasma cutting (constricted tungsten arc) machines. Anvil offers a simple approach to cutting the hole. Hand–held templates are sized to match your plasma cutter. Welded Outlet Fittings SPF-8.14 RECOMMENDED SETTINGS FOR MICROWIRE WELDING PROCESS Header Size Pipe Wall Thickness Welded OutletMTM-40 & GR-40 Electrode Size Welding Current Arc. Volts Wire Feed Travel Speed In./mm In./mm In./mm AMPS-DC POS.IPM IPM 11⁄4 - 2 31-50 0.065 2 1⁄2 - 2 0.035 100-130 16-20 210 25-30 13-50 21⁄2 - 4 0.035 115-150 17-21 270 20-25 63-100 0.109 3 1⁄2 - 2 0.035 110-140 18-22 220 25-30 13-50 21⁄2 - 4 0.035 120-160 19-22 290 20-25 63-100 21⁄2 - 4 63-100 0.083 2.5 1⁄2 - 2 0.035 110-140 17-20 210 20-25 13-50 21⁄2 - 4 0.035 120-150 17-20 270 20-25 63-100 0.120 3 1⁄2 - 2 0.035 120-160 19-22 290 20-25 13-50 21⁄2 - 4 0.035 130-160 19-22 240 20-25 63-100 5-6 125-150 0.109 3 1⁄2 - 2 0.035 120-150 17-20 210 20-25 13-50 21⁄2 - 4 0.035 130-150 18-20 270 15-20 63-100 0.134 3.5 1⁄2 - 2 0.035 130-160 19-22 290 20-25 13-50 21⁄2 - 4 0.035 140-160 20-22 270 15-20 63-100 21⁄2 - 4 0.045 180-205 20-24 245 27-32 63-100 8 200 0.109 3 1⁄2 - 2 0.035 120-150 17-20 240 20-25 13-50 21⁄2 - 4 0.035 130-150 18-20 260 15-20 63-100 21⁄2 - 4 0.045 170-220 18-22 290 12-18 63-100 0.148 3.5 1⁄2 - 2 0.035 130-160 19-22 240 20-25 13-50 21⁄2 - 4 0.035 140-160 20-22 260 15-20 63-100 21⁄2 - 4 0.045 180-225 20-24 290 12-18 63-100 Anvil assumes no liability for any consequential damages resulting from the improper use of its Welded Outlet Fittings, nor for any recommendations made with respect to installation procedures. Shielding Gas Flow (for all sizes) 20-25 CfH 1) Co2 - Deeper penetration, faster welding, low cost. 2) 25% - Argon, 75% - Co2, Recommended for .134 wall and lighter, high welding speeds without melt through, minimum distortion and spatter, good penetration. 3/05 - 88 PROJECT INFORMATION:APPROVAL S TAMP: Project: Date:Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Merit® Product - Submittal Sheet ® Weld-Miser™ Tee-Let® Welding Outlet Fittings For Fire Protection & Other Low Pressure Piping Systems Merit Weld-Miser™ Tee-Let® Welding Branch Outlet Fittings offer the user a high strength, low cost forged threaded and grooved line of fittings spe- cifically designed and manufactured to be installed on Schedules 5 thru 10, proprietary thin wall flow pipe and standard wall pipe. Merit Tee-Lets are forged steel welding outlet fittings. The material used in manufacture meets the chemical and physical requirements of ASTM A 53, Grades A or B, Type E, Tee-Lets employ a low weld volume design to provide for either a partial or full penetration weld employing a single pass with minimum burn-through and pipe distortion. Weld Miser Tee-Lets are recommended for use on proprietary thin wall, Schedules 5, 10 and 40 pipe. Threads comply with ANSI B1.20.1 or ISO7/1. They are UL Listed and FM Approved for use conforming to the requirements of Bulletin 13 1999 of the National Fire Protection Association. When used in fire sprin- kler systems, Tee-Lets are rated for 300 psi. When used in mechanical systems, maximum pressures are calculated using criteria developed for ASME B31 piping code. TEE-LET W ELDED OUTLET FITTING (UL VIZU — EX6032, FM APPROVAL GUIDE CHAPTER 1 – PIPE FITTINGS) Outlet Model Outlet Pipe Size (Inch) Header Pipe Size (Inch) Rated Pressure (psig) Tee-Let Type A (F-Threaded End) 1⁄2, 3⁄4, 1 1⁄2 - 8 (Sch.10, 40) 30011⁄4, 11⁄2, 2, 21⁄2, 3, 4 1⁄2 - 4 (Sch. 5, DynaFlow) 2 4 (EZ-Flow) 2, 4 6 (EZ-Flow) Tee-Let Type C (Grooved End) 11⁄4 - 8 11⁄4 - 8 (Sch.10, 40)30021⁄2 - 8 1⁄2 - 4 (Sch. 5, DynaFlow) Tee-Let Type C/R (Roll Grooved End) 11⁄4 - 6 11⁄4 - 8 (All Schedules)300 1) Size on size (ie 2 x 2) Tee-Lets are not FM Approved 2) FM rated working pressure when welded on Sch. 5 or nonthreadable lightwell pipe is 175 psi. FM APPROVED For listing/approval details contact your AnvilStar Representative. Page 1 of 5 3/05 - 89 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Merit® Product - Submittal Sheet ® Weld-Miser™ Tee-Let® Welding Outlet Fittings Unified Design™ Series Merit's Unified Design Series carries all important design considerations into its entire line of welding branch outlet fittings. Merit® Weld-Miser™ Tee-Lets® are designed and Manufactured to reduce the amount of weld required to install the Tee-Lets on thin wall or proprietary flow pipe. Typically only one weld-pass completes the installation. Merit Tee-Lets install with less weld volume than any other brand of welding outlet fittings for fire sprinkler applications. To accomplish this: • The contoured end of the fittings employs a reduced outside diameter. Two major advantages are immediately apparent: • The thinner wall on the contoured end permits welding temperatures to be matched to the thickness of the branch line or main thereby insuring complete penetration without cold welds, weld roll-off, burn-through or excessive distortion. • On smaller sizes a heavier section is maintained on the threaded end of the fitting. This protects the threads from damage during shipping and handling prior to installation as well as from weld distortion. • Each outlet size 11⁄2" and larger, whether male or female threaded, cut grooved or beveled requires the same hole size in the header pipe. This simplifies the installation process. General Specifications • Tee-Let welding outlet fittings are manufactured from highly weldable steel which conforms to the chemical and physical requirements of ASTM A-53, Grades A or B, Type E. Ease of installation is assured when automatic welding equipment is used to install Merit Tee-Lets. • Threads are cut in accordance with the requirements of ANSI B1.20.1, national standard for tapered pipe threads, or ISO-7-1 threads are available. • Tee-Let threaded and grooved welding outlet fittings are UL/ULC Listed and FM approved for use in the fire sprinkler systems installed in accordance with the requirements of NFPA Bulletin 13. They are rated for 300 PSI operation in fire sprinkler systems, and higher pressures in other non-critical piping systems. • Tee-Lets are offered in a wide variety of header sizes. The consolidated header sizes shown in the following charts allow the fittings to be installed on more than one header size, permitting the first size listed to fit the header perfectly, while a small gap along the longitudinal center line of the header will appear for the second size listed. • Merit® Weld-Miser™ Tee-Lets® are identified by a lot number that provides full traceability per ISO-9000 specifications. For Your Piping Systems Specify Weld-Miser™ Tee-Let® Branch Outlet Fittings shall be Merit Weld-Miser Tee-Let, Lightweight forged steel, employing low weld volume profile to provide for full penetration welds with minimum burn through and pipe distortion on Schedule 5 thru 10, proprietary thin wall, and standard wall pipe. Threads are to be ANSI B1.20.1, or ISO-7-1, and the bore of the fittings calculated to improve flow. Welding outlets to be UL Listed, FM Approved for use conforming to NFPA, Bulletin 13 and pressure rated for 300 PSI maximum. Method No. 1 Specify quantity desired followed by the part number shown in the “dimensions” chart for the type and size of outlet desired. Method No. 2 Use the following system How to Order - Use either of the following methods for ordering Merit® Weld-Miser™ Tee-Let®. Quantity Part Number Quantity Outlet Size –x Header Size Weight End Type Merit Tee-Let Material Steel Always order a few more than actually required for the job. Column “A” of Chart Insert size consolidation from Column “B” of chart Sch. 10 Standard A - Female Thread B - Male Thread C - Cut Groove C/R - Roll Groove Page 2 of 5 3/05 - 90 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Merit® Product - Submittal Sheet ® WELD -MISER™ TEE-LET® DIMENSIONS & PART NUMBERS Part Number Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter D Make Up M Weight Each NPT (BSPT)In (mm)In (mm)In (mm)In (mm)In (mm)Lb. (kg) 1020020 2 x 50 x 2 1.750 2.067 0.875 0.857 1120020 50 44.5 52.5 22.2 0.38 1020025 21⁄2 1.750 2.067 0.875 0.829 1120025 65 44.5 52.5 22.2 0.38 1020030 3 1.750 2.067 0.875 0.829 1120030 80 44.5 52.5 22.2 0.39 1020040 4 1.750 2.067 0.875 0.800 1120040 100 44.5 52.5 22.2 0.36 1020050 5 1.750 2.067 0.875 0.743 1120050 125 44.5 52.5 22.2 0.34 1020060 6 1.750 2.067 0.875 0.743 1120060 150 44.5 52.5 22.2 0.34 1020080 8 1.750 2.067 0.875 0.743 1120080 200 44.5 52.5 22.2 0.34 1025025 21⁄2 x 65 x 21⁄2 2.215 2.469 1.125 1.250 1125025 65 54.0 62.7 28.6 0.55 1025030 3 2.215 2.469 1.125 1.200 1125030 80 54.0 62.7 28.6 0.55 1025040 4 2.215 2.469 1.125 1.150 1125040 100 54.0 62.7 28.6 0.52 1025050 5 2.215 2.469 1.125 1.150 1125050 125 54.0 62.7 28.6 0.52 1025060 6 2.215 2.469 1.125 1.150 1125060 150 54.0 62.7 28.6 0.52 1025080 8 2.215 2.469 1.125 1.150 1125080 200 54.0 62.7 28.6 0.52 1030030 3 x 80 x 3 2.500 3.068 1.500 3.100 – 80 63.5 77.9 38.1 1.41 1030040 4 2.500 3.068 1.500 3.100 – 100 63.5 77.9 38.1 1.41 1030050 5 2.500 3.068 1.500 3.100 – 125 63.5 77.9 38.1 1.412 1030060 6 2.500 3.068 1.500 3.100 – 150 63.5 77.9 38.1 1.412 1030080 8 2.500 3.068 1.500 3.100 – 200 63.5 77.9 38.1 1.41 1040040 4 x 100 x 4 3.000 4.026 2.000 5.000 – 100 76.2 102.3 50.8 2.27 1040050 5 3.000 4.026 2.000 5.000 – 125 76.2 102.3 50.8 2.27 1040060 6 3.000 4.026 2.000 5.000 – 150 76.2 102.3 50.8 2.27 1040080 8 3.000 4.026 2.000 5.000 – 200 76.2 102.3 50.8 2.27 D C M A B Type A Female Thread Note: Part #1002002 is not UL Listed or FM Approved All size on size (ie 2 x 2) Tee-Lets are not FM Approved Weld-Miser™ Tee-Let® Welding Outlet Fittings WELD-MISER™ T EE-LET® DIMENSIONS & PART NUMBERS Part Number Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter D Make Up M Weight Each NPT (BSPT)In (mm)In (mm)In (mm)In (mm)In (mm)Lb. (kg) 1002002 1⁄4 x 11⁄4 - 8 0.080 – 6 x 6 - 200 0.04 1005012 1⁄2 x 13 x 11⁄4 - 11⁄2 1.063 0.700 0.500 0.171 – 32 - 40 27.0 17.8 12.7 0.08 1005015 11⁄2 - 2 1.063 0.700 0.500 0.171 – 40 - 50 27.0 17.8 12.7 0.08 1005020 2 - 21⁄2 1.063 0.700 0.500 0.171 – 50 - 65 27.0 17.8 12.7 0.08 1005025 21⁄2 - 8 1.063 0.700 0.500 0.169 – 65 - 200 27.0 17.8 12.7 0.08 1007012 3⁄4 x 19 x 11⁄4 - 11⁄2 1.125 0.900 0.500 0.260 – 32 - 40 28.6 22.9 12.7 0.12 1007015 11⁄2 - 2 1.125 0.900 0.500 0.260 – 40 - 50 28.6 22.9 12.7 0.12 1007020 2 - 21⁄2 1.125 0.900 0.500 0.260 – 50 - 65 28.6 22.9 12.7 0.12 1007025 21⁄2 - 8 1.125 0.900 0.500 0.256 – 65 - 200 28.6 22.9 12.7 0.12 1010012 1 x 25 x 11⁄4 - 11⁄2 1.250 1.145 0.500 0.331 1110012 32 - 40 31.8 29.1 12.7 0.15 1010015 11⁄2 - 2 1.250 1.145 0.500 0.331 1110015 40 - 50 31.8 29.1 12.7 0.15 1010020 2 - 21⁄2 1.250 1.145 0.500 0.320 1110020 50 - 65 31.8 29.1 12.7 0.15 1010025 21⁄2 - 3 1.250 1.145 0.500 0.314 1110025 65 - 80 31.8 29.1 12.7 0.14 1010030 3 - 4 1.250 1.145 0.500 0.309 1110030 80 - 100 31.8 29.1 12.7 0.14 1010050 5 - 8 1.250 1.145 0.500 0.291 1110050 125 - 200 31.8 29.1 12.7 0.13 1012012 11⁄4 x 32 x 11⁄4 - 11⁄2 1.375 1.490 0.500 0.432 1112012 32 - 40 34.9 37.8 12.7 .019 1012015 11⁄2 - 2 1.375 1.490 0.500 0.421 1112015 40 - 50 34.9 37.8 12.7 .019 1012020 2 - 21⁄2 1.375 1.490 0.500 0.421 1112020 50 - 65 34.9 37.8 12.7 .019 1012025 21⁄2 - 3 1.375 1.490 0.500 0.411 1112025 65 - 80 34.9 37.8 12.7 .019 1012030 3 - 4 1.375 1.490 0.500 0.389 1112030 80 - 100 34.9 37.8 12.7 .018 1012050 5 - 8 1.375 1.490 0.500 0.389 1112050 125 - 200 34.9 37.8 12.7 .018 1015015 11⁄2 x 40 x 11⁄2 1.625 1.610 0.875 0.477 1115015 40 41.3 40.9 22.2 .022 1015020 2 1.625 1.610 0.875 0.477 1115020 50 41.3 40.9 22.2 .022 1015025 21⁄2 1.625 1.610 0.875 0.477 1115025 65 41.3 40.9 22.2 .022 1015030 3 - 4 1.625 1.610 0.875 0.477 1115030 80 - 100 41.3 40.9 22.2 .022 1015040 4 1.625 1.610 0.875 0.477 1115040 100 41.3 40.9 22.2 .022 1015050 5 - 8 1.625 1.610 0.875 0.477 1115050 125 - 200 41.3 40.9 22.2 .022 Page 3 of 5 3/05 - 91 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Merit® Product - Submittal Sheet ® Weld-Miser™ Tee-Let® Welding Outlet Fittings Note: Tee-Lets are manufactured to fit size-on-size, that is the contoured shape on a given Tee-Let is made to fit perfectly on the first listed header size. If installed on the second header size marked on the fitting, a slight gap of approximately 1⁄32" will appear along the longitudinal centerline of the header. For example, a 1" x 2 - 21⁄2" Tee-Let, is a 1" outlet fitting manufactured to fit perfectly on the 2" header size listed, while leaving a 1⁄32" gap along the longitudinal centerline of the 21⁄2" size. If a perfect fit is required for a 21⁄2" header pipe, then a 1" x 21⁄2 - 3" Tee-Let would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. Type B Male Thread Standard Weight Type C Cut Groove Standard Weight E C B A F D E C B A F D WELD -MISER™ TEE-LET® - DIMENSIONS (N OMINAL SIZES 1" THRU 2") Male Thread Std. Wt. Cut Groove Std. Wt. Roll Groove Sch. 10 Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter D Outside Diameter E Wall Thickness F Weight Each NPT (BSPT)NPT (BSPT)NPT (BSPT)In.(mm)In.(mm)In.(mm)In.(mm)In.(mm)In.(mm)Lb. (kg) 1310012 2010012 2210012 1 x 25 x 11⁄4 - 11⁄2 3 1.049 1.315 0.133 1.500 32 - 40 80 26.6 33.4 3.4 30 1310015 2010015 2210015 11⁄2 - 2 3 1.049 1.315 0.133 1.500 40 - 50 80 26.6 33.4 3.4 30 1310020 2010020 2210020 2 - 21⁄2 3 1.049 1.315 0.133 1.500 50 - 65 80 26.6 33.4 3.4 30 1310025 2010025 2210025 21⁄2 - 4 3 1.049 1.315 0.133 1.500 65 - 100 80 26.6 33.4 3.4 30 1310050 2010050 2210050 5 - 8 3 1.049 1.315 0.133 1.500 125 - 200 80 26.6 33.4 3.4 30 1312012 2012012 2212012 11⁄4 x 32 x 11⁄4 3 1.368 1.660 0.140 1.500 32 80 34.7 42.2 3.6 30 1312015 2012015 2212015 11⁄2 3 1.368 1.660 0.140 1.500 40 80 34.7 42.2 3.6 30 1312020 2012020 2212020 2 - 21⁄2 3 1.368 1.660 0.140 1.500 50 - 65 80 34.7 42.2 3.6 30 1312025 2012025 2212025 3 - 4 3 1.368 1.660 0.140 1.500 80 - 100 80 34.7 42.2 3.6 30 1312050 2012050 2212050 5 - 8 3 1.368 1.660 0.140 1.500 125 - 200 80 34.7 42.2 3.6 30 1315015 2015015 2215015 11⁄2 x 40 x 11⁄2 3 1.610 1.900 0.145 1.500 40 80 40.9 48.3 3.7 30 1315020 2015020 2215020 2 3 1.610 1.900 0.145 1.500 50 80 40.9 48.3 3.7 30 1315025 2015025 2215025 21⁄2 3 1.610 1.900 0.145 1.500 65 80 40.9 48.3 3.7 30 1315030 2015030 2215030 3 - 4 3 1.610 1.900 0.145 1.500 80 - 100 80 40.9 48.3 3.7 30 1315050 2015050 2215050 5 - 8 3 1.610 1.900 0.145 1.500 125 - 200 80 40.9 48.3 3.7 30 1320020 2020020 – 2 x 50 x 2 3 2.067 2.375 0.154 1.500 50 80 52.5 60.3 3.9 30 1320025 2020025 – 21⁄2 3 2.067 2.375 0.154 1.500 65 80 52.5 60.3 3.9 30 1320030 2020030 – 3 3 2.067 2.375 0.154 1.500 80 80 52.5 60.3 3.9 30 1320035 2020040 – 4 3 2.067 2.375 0.154 1.500 100 80 52.5 60.3 3.9 30 1320050 2020050 – 5 3 2.067 2.375 0.154 1.500 125 80 52.5 60.3 3.9 30 1320060 2020060 – 6 3 2.067 2.375 0.154 1.500 150 80 52.5 60.3 3.9 30 1320080 2020080 – 8 3 2.067 2.375 0.154 1.500 200 80 52.5 60.3 3.9 30 Page 4 of 5 3/05 - 92 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative Merit® Product - Submittal Sheet ® Weld-Miser™ Tee-Let® Welding Outlet Fittings Note: Tee-Lets are manufactured to fit size-on-size, that is the contoured shape on a given Tee-Let is made to fit perfectly on the first listed header size. If installed on the sec- ond header size marked on the fitting, a slight gap of approximately 1⁄32" will appear along the longitudinal centerline of the header. For example, a 1" x 2 - 21⁄2" Tee-Let, is a 1" outlet fitting manufactured to fit perfectly on the 2" header size listed, while leaving a 1⁄32" gap along the longitudinal centerline of the 21⁄2" size. If a perfect fit is required for a 21⁄2" header pipe, then a 1" x 21⁄2 - 3" Tee-Let would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. Type BMale Thread Standard Weight Type CCut Groove Standard Weight E C B A F D E C B A F D Type C/RRoll Groove Schedule 10 E C B A F D WELD-MISER™ TEE -LET® - DIMENSIONS (NOMINAL SIZES 21⁄2" THRU 8") Male Thread Std. Wt. Cut Groove Std. Wt. Roll Groove Sch. 10 Nominal Outlet A Nominal Header B Outlet Length C Inside Diameter - D Outside Diameter E Wall Thickness - F Weight Each Standard Weight Schedule 10 Standard Weight Schedule 10 NPT (BSPT)NPT (BSPT)NPT (BSPT)In.(mm)In.(mm)In.(mm)In.(mm)In.(mm)In.(mm)In.(mm)In.(mm)Lb. (kg) 1325025 2025025 2225025 21⁄2 x 65 x 21⁄2 3 2.469 2.635 2.875 0.203 0.120 1.500 2125025 65 80 62.7 67.0 76.2 5.0 3.0 30 1325030 2025030 2225030 3 3 2.469 2.635 2.875 0.203 0.120 1.500 2125030 80 80 62.7 67.0 76.2 5.0 3.0 30 1325035 2025040 2225035 4 3 2.469 2.635 2.875 0.203 0.120 1.500 2125040 100 80 62.7 67.0 76.2 5.0 3.0 30 1325050 2025050 2225050 5 3 2.469 2.635 2.875 0.203 0.120 1.500 2125050 125 80 62.7 67.0 76.2 5.0 3.0 30 1325060 2025060 2225060 6 3 2.469 2.635 2.875 0.203 0.120 1.500 2125060 175 80 62.7 67.0 76.2 5.0 3.0 30 1325080 2025080 2225080 8 3 2.469 2.635 2.875 0.203 0.120 1.500 2125080 200 80 62.7 67.0 76.2 5.0 3.0 30 1330030 2030030 2230030 3 x 80 x 3 3 3.068 3.260 3.500 0.216 0.120 1.500 80 80 78.0 83.0 88.0 5.0 3.0 30 1330035 2030035 2230035 31⁄2 3 3.068 3.260 3.500 0.216 0.120 1.500 85 80 78.0 83.0 88.0 5.0 3.0 30 1330040 2030040 2230040 4 3 3.068 3.260 3.500 0.216 0.120 1.500 100 80 78.0 83.0 88.0 5.0 3.0 30 1330050 2030050 2230050 5 3 3.068 3.260 3.500 0.216 0.120 1.500 125 80 78.0 83.0 88.0 5.0 3.0 30 1330060 2030060 2230060 6 3 3.068 3.260 3.500 0.216 0.120 1.500 150 80 78.0 83.0 88.0 5.0 3.0 30 1330080 2030080 2230080 8 3 3.068 3.260 3.500 0.216 0.120 1.500 200 80 78.0 83.0 88.0 5.0 3.0 30 1340040 2040040 2240040 4 x 100 x 4 4 4.026 4.260 4.500 0.237 0.120 1.500 100 100 102.0 108.0 114.0 6.0 3.0 30 1340050 2040050 2240050 5 4 4.026 4.260 4.500 0.237 0.120 1.500 125 100 102.0 108.0 114.0 6.0 3.0 30 1340060 2040060 2240060 6 4 4.026 4.260 4.500 0.237 0.120 1.500 150 100 102.0 108.0 114.0 6.0 3.0 30 1340080 2040080 2240080 8 4 4.026 4.260 4.500 0.237 0.120 1.50 200 100 102.0 108.0 114.0 6.0 3.0 30 – 2060060 2260060 6 x 150 x 6 4 6.065 6.357 6.625 0.280 0.134 1.500 150 100 155.0 161.5 168.3 7.1 3.0 30 – 2060080 2260080 8 4 6.065 6.357 6.625 0.280 0.134 1.50 200 100 155.0 161.5 168.3 7.1 3.0 30 – 2080080 – 8 x 8 4 7.981 8.329 8.625 0.322 0.148 1.50 200 x 200 100 203.0 212.0 213.0 8.0 3.0 30 Page 5 of 5 0($-ANUFACTURING )NC THREADED ACCESSORIES Fig. 10 THREADED STUDS Fig. 15 & 15L MACHINE THREAD HANGER ROD Fig. 15 RIGHT-HAND THREADS Fig. 15L RIGHT- AND LEFT-HAND THREADS Fig. 20 & 21 CONTINUOUS THREADED ROD Fig. 20* PLAIN Fig. 21 ELECTRO-GALVANIZED  & & -AX2EC ,OADLBS7T0ER )NCHLBS 2OD 3IZE  &  & -AX2EC ,OADLBS7T0ER )NCHLBS 4HREAD ,ENGTH # 2OD 3IZE -AX2EC ,OADLBS2OD 3IZE  &  & FTFTFT 0ACKAGING &EET0ER"UNDLE 7T0ER &OOTLBS FUNCTION: Designed for use in pipe hanger assembly. MATERIAL: Low carbon steel FINISH: Plain ORDERING: Specify rod size, length (B) and figure number. FUNCTION: Designed for use in pipe hanger assembly. MATERIAL: Low carbon steel FINISH: Plain ORDERING: Specify rod size, length (B) and figure number. FUNCTION: Useful in applications where stud lengths cannot be predetermined. MATERIAL: Low carbon steel ORDERING: Specify rod size, length and figure number. Available in stainless steel. To order, specify 304 or 316 and add suffix SS to figure number. Price on request. Available in stain- less steel. To order, specify 304 or 316 and add suffix SS to figure number. Price on request. *Available in stainless steel. To order, specify 304 or 316 and add suffix SS to figure number. Price on request. X"    X"    X"    X"    X"    X"      X"      X"      X"     X"      X"                                                             0($-ANUFACTURING )NC FUNCTION: Designed for supporting and stabilizing vertical pipe runs. The PVC coating on Fig. 553 protects the pipe from the metal surface of the clamp. When possible, the clamp should be placed under a coupling, hub, or lugs welded to the pipe. APPROVALS: Complies with Federal Specification A-A-1192A (Type 8). Underwriters' Laboratories listed and Factory Mutual approved 3/4" to 8" sizes only. Manufacturers’ Standardization Society SP-69 (Type 8). MATERIAL: Low carbon steel ORDERING: Specify pipe size and figure number. Fig. 550, 551 & 553 RISER CLAMP Fig. 550* PLAIN Fig. 551 ELECTRO-GALVANIZED Fig. 553 PLAIN WITH PVC COATING RISER CLAMPS *Available in stainless steel. To order, specify 304 or 316 and add suffix SS to figure number. Price on request. Installation practice for Model 550 Riser Clamps The Model #550 riser clamp is designed for supporting and stabilizing vertical pipe runs. When possible the clamp should be placed under a coupling, hub or welded lugs on steel pipe.   8     8     8     8     8     8     8     8     8     8     8     8     8     8     8     8     8     8     8     8     8   0IPE -AX2EC 7T%ACH 3IZE " "OLT3IZE ,OADLBS INLBS 0($-ANUFACTURING )NC FUNCTION: Designed for the suspension of non-insulated stationary pipe lines. The knurled insert nut that allows a vertical adjustment after installation, is tapped to NFPA reduced rod size standards. Fig. 141F has a layer of felt which separates the pipe from the hanger to reduce vibration and sound. APPROVALS: Underwriters’ Laboratories listed and Factory Mutual approved Fig. 141 3⁄4" to 8" sizes only. Complies with Federal Specification A-A-1192A (Type 10), Manufacturers’ Standardization Society SP-69 (Type 10) and NFPA standards for reduced rod sizes. ORDERING: Specify pipe size and figure number. Fig. 141 & 141F NFPA SWIVEL RING HANGER Fig. 141 PRE-GALVANIZED Fig. 141F PRE-GALVANIZED WITH FELT LINING FUNCTION: Designed for the suspension of non-insulated stationary pipe lines. The knurled insert nut, allows for vertical adjustment after installation. Fig. 151F has a layer of felt which separates the pipe from the hanger to reduce vibration and sound. APPROVALS: Underwriters’ Laboratories listed and Factory Mutual approved Fig. 151 21/2" to 8" sizes only. Complies with Federal Specification A-A-1192A (Type 10), and Manufacturers’ Standardization Society SP-69 (Type 10). ORDERING: Specify pipe size and figure number. Fig. 151 & 151F SWIVEL RING HANGER Fig. 151 PRE-GALVANIZED Fig. 151F PRE-GALVANIZED WITH FELT LINING ADJUSTABLE SWIVEL RING HANGERS Note: If ordering Fig. 151F felt lined hangers for pipe sizes of 31/2" or under, order the next largest size to allow for the thickness of the felt lining. MATERIAL: Low carbon steel                                   2OD 3IZE ! -AX2EC ,OADLBS 7T%ACH INLBS 0IPE 3IZE "!DJ #$%                                                                2OD 3IZE ! 0IPE 3IZE 7T%ACH INLBS -AX2EC ,OADLBS!DJ #"$% Note: If ordering Fig. 141F felt lined hangers for pipe sizes of 31/2" or under, order the next largest size to allow for the thickness of the felt lining.MATERIAL: Low carbon steel 0($-ANUFACTURING )NC  Fig. 259 RETAINING STRAP For Fig. 250 & 270                                    &IG  2OD 3IZE     2OD 3IZE -AX0IPE 3IZE -AX2EC ,OADLBS 7T%ACH INLBS FUNCTION: Designed for use with Fig. 250, 250-1, 270 and 270-1 to eliminate possible movement of the beam clamp due to vibration. MATERIAL: Low carbon steel FINISH: Plain or electro-galvanized ORDERING: Specify type number, length, finish and figure number. Fig. 290 PURLIN CLAMP 7T%ACHINLBS ,ENGTH#INCHES 4YPE.O 3ELECTION#HART               4YPE .O     3IZE  -ODEL.O Note: 1 inch should be added to beam flange width to determine length. FUNCTION: Designed for use with large-lip rolled steel purlins to eliminate the need to modify steel purlin for standard C-clamp. APPROVALS: Underwriters’ Laboratories listed and Factory Mutual approved. MATERIAL: Malleable iron with hardened steel cup point set screw. FINISH: Plain ORDERING: Specify figure number. FUNCTION: Designed for use with Fig. 350, 350-1, 360 and 360-1 to eliminate possible movement of the beam clamp due to vibration. MATERIAL: Low carbon steel FINISH: #358 Pre-galvanized; #359 Plain or electro-galvanized ORDERING: Specify rod size, length, finish and figure number. BEAM CLAMPS Available in stainless steel. To order, specify 304 or 316 and add suffix SS to figure number. Price on request.         &IG  2OD 3IZE Fig. 358 RETRO-FIT RETAINING STRAP Fig. 359 RETAINING STRAP For Fig. 350 & 360 Available in stainless steel. To order, specify 304 or 316 and add suffix SS to figure number. Price on request. &IG &IG   7T%ACHINLBS ,ENGTH#INCHES   7T%ACHINLBS ,ENGTH#INCHES   0($-ANUFACTURING )NC Fig. 350 & 350-1 MALLEABLE IRON BEAM CLAMP Fig. 350 WITH LOCKNUT Fig. 350-1 WITHOUT LOCKNUT BEAM CLAMPS FUNCTION: Designed for attaching hanger rod to the top flange of a beam or bar joist, where the flange thickness does not exceed 3/4 inch. The open U design permits rod adjustment. The universal design of the 3/8 Fig. 350 allows it to be used in an inverted position on the bottom flange of a beam as well. APPROVALS: Underwriters’ Laboratories listed. Factory Mutual approved 3/8" and 1/2" sizes only. Complies with Federal Specification A-A-1192A (Type 19) and Manufacturers’ Standardization Society SP-69 (Type 19). When used in an inverted position on the bottom of a beam flange the 3/8 Fig. 350 also complies with Federal Specification A-A- 1192A (Type 23) and Manufacturers’ Standardization Society SP-69 (Type 23) (Only for Fig. 350 with locknut). MATERIAL: Malleable iron with hardened steel cup point set screw FINISH: Plain or electro-galvanized ORDERING: Specify rod size, finish and figure number. Fig. 360 & 360-1 MALLEABLE IRON WIDE MOUTH BEAM CLAMP Fig. 360 WITH LOCKNUT Fig. 360-1 WITHOUT LOCKNUT                     Note: See MSS SP-69 specs for proper set screw torque values. -AX2EC ,OADLBS 7T%ACHINLBS -AX 0IPE 3IZE WITHNUT WONUT 2OD 3IZE !"#%$ -AX2EC ,OADLBS 7T%ACHINLBS -AX 0IPE 3IZE                              WITHNUTWONUT 2OD 3IZE !"# $ Note: See MSS SP-69 specs for proper set screw torque values. Reversible design approved for bottom beam use. FUNCTION: Designed for attaching hanger rod to the top flange of a beam or bar joist, where the flange thickness does not exceed 11/4 inches. The open U design permits rod adjustment. APPROVALS: Underwriters’ Laboratories listed and Factory Mutual approved (3/8 & 1/2 sizes only). Complies with Federal Specification A-A-1192A (Type 19) and Manufacturers’ Standardization Society SP-69 (Type 19) (Only for Fig. 360 with locknut). MATERIAL: Malleable iron with hardened steel cup point set screw FINISH: Plain or electro-galvanized ORDERING: Specify rod size, finish and figure number.   % ∆ ∆ I ,r-Hiiii-Drop-fn Anchor (HDI) ~System I I I , .I 1 I t 4 ~~ Flush-Mount Internal Thread Anchor Meets Wide Range of Fastener Requirements Advantages . Installs flush with base material. . Shallow embedment depth for high performance. . Internal thread .Anchor is preassembled for fast, easy installation. Listings/ Approvals . Underwriter Laboratories Control No 767G . Factory Mutual serial No 22765 . International Conference of Building Officials Report No 2895 .Southern Building Code Congress International Report No 8913 . City of Los Angeles Report No 23709 . Meets the description in Federal Specification FF-S-325, Group VIII, Type 1 Materials . HDI Carbon Steel material meets the requirements of SAE 111 OM or SAE 1010 for the 1/4", 3/8" and 1/2" HDI's and AISI12L14 for the 5/8" and 3/4" HDI's. . HDI Stainless Steel material meets the requirements of AISI 303. . Carbon Steel HDI plated with a dull zinc finish for corrosion protection in accordance with ASTM B633, Sc. 1, Type III. Installation Instructions 'J~r~: lîîl 2. Hammer-drill the hole. 1. Adjust the depth gauge so anchor will be flush with the base material surface. ~ . ~ '11 ':I.!. fÎI~ I'~ I~ 3. Clean hole. 4.lnstall anchor using proper setting tool. Setting tool to be driven into anchor until setting tool shoulder meets top of anchor. Sammys® for Wood .......................................................................................................................... 4 Sidewinder® for Wood ....................................................................................................................... 5 Sammys Swivel Head™ for Wood ......................................................................................................5 Sammys® for Steel ............................................................................................................................ 6 Sidewinder® for Steel ........................................................................................................................ 7 Sammys Swivel Head™ for Steel .......................................................................................................7 Sammy X-Press® ...............................................................................................................................8 Sammy X-Press Sidewinder™ ............................................................................................................8 Sammy X-Press Swivel™ ...................................................................................................................9 Sammy X-Press It® Installation Tool ..................................................................................................9 Sammys® for Concrete ................................................................................................................... 10 Sidewinder® for Concrete ................................................................................................................10 Sammys Swivel Head™ for Concrete ................................................................................................11 Concrete/Wood Installation Kit ........................................................................................................ 11 Sammys Toggle™ ............................................................................................................................ 12 Ceiling Screws .................................................................................................................................12 Dektite® Pipe Flashing .....................................................................................................................13 Speedy Pole Tool™.......................................................................................................................... 13 Spot Rite Level™ ..............................................................................................................................13 Approvals and Listings ....................................................................................................................14 Special Notes ..................................................................................................................................15 TABLE OF CONTENTS Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used. Allowance for special characteristics in materials, differences in materials, differences in types of materials being joined, unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered. Due to possible differences in specifications, applications, and interpretation of results, purchasers and specifiers must make their own evaluation of the products, to determine the suitability of these products for intended use. All warranties of Buildex products, expressed or implied, including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following: Buildex will repair or replace any product which, within twelve months after sale by Buildex or its distributors, is found by Buildex to be defective in material or workmanship - normal wear and tear accepted. This is the sole warranty of Buildex and the sole remedy available to distributor or buyer. Buildex shall not be liable for any injury, loss or damage, direct, indirect, or consequential, arising out of the use of, or the inability to use, any Buildex product. For the most up to date information, visit www.itwbuildex.com 3 To find a distributor near you, call 800-BUILDEX INSTALLATION STEPS - VERTICAL INTO CONCRETE: 1. Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2” with a hammer/rotary hammer drill set on impact mode. 2. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). 3. Insert the CST screw into the nut driver. 4. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. 5. The concrete screw is ready to receive 1/4”, 3/8”, 1/2”, or metric all thread rod or bolt stock. (#14SW red nut driver used with 1/2” screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode — doing so will destroy the pullout factor of the screw. INSTALLATION STEPS - HORIZONTAL INTO CONCRETE: 1. Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2” with a hammer/ rotary hammer drill set on impact mode. 2. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14SW (red) nut driver (p/n 8114910) into the opposite end. 3. Insert the SWC screw into the nut driver. 4. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. 5. The SWC screw is ready to receive 1/4”, 3/8” or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode — doing so will destroy the pullout factor of the fastener. INSTALLATION INSTRUCTIONS FOR CONCRETE SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. INSTALLATION STEPS - VERTICAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS® into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. 4. The SAMMYS is now ready to receive 1/4”, 3/8”, 1/2” or metric all thread rod, bolt stock. (The 1/2” requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. INSTALLATION STEPS - HORIZONTAL INTO WOOD & STEEL: 1. Insert the appropriate nut driver into a 3/8” or 1/2” portable drill. 2. Insert the SAMMYS into the #14SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. 3. When the nut driver spins freely on the SAMMYS, stop the drill and remove. 4. The unit is now ready to receive 1/4”, 3/8”, M10, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. INSTALLATION INSTRUCTIONS FOR WOOD & STEEL 4 For the most up to date information, visit www.itwbuildex.com Wood Flooring Wood Joist Double Sheetrock Ceiling Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Box Qty Case Qty VERTICAL MOUNT 1/4"8002957 GST 100 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)25 125 1/4"8003957 GST 200 1/4 x 2"1760 (Fir)25 125 3/8"8007957 GST 10 1/4 x 1"210 (7/16” OSB) 670 (3/4” Ply)300 25 125 3/8"8008957 GST 20 1/4 x 2"1760 (Fir)850 1475 25 125 3/8"8068925 GST 20-SS 1/4 x 2"1760 (Fir)850 25 125 3/8"8009925 GST 25-380 3/8 x 2-1/2"2113 (Fir)1500 25 125 3/8"8010957 GST 30 1/4 x 3"2060 (Fir)1500 1475 25 125 3/8"8069925 GST 30-SS 1/4 x 3"2060 (Fir)25 125 1/2"8013925 GST 2 1/4 x 2"1760 (Fir)25 125 1/2"8015925 GST 3 1/4 x 3"2275 (Fir)25 125 Not less than 2” nominal width (1-1/2”) Not less than 3” nominal thickness (2-1/2”) (depth or side of vertical member) #14 Black Nut Driver Part # 8113910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. #14 SW Red Nut Driver Part # 8114910 Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for GST 25-380 . Tool available on page 11. For vertical use - install in center of lower face. Minimum 2” embedment into base material for NFPA 13 compliance. • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. SAMMYS® FOR WOOD Application Product Features Watch a video demonstration atwww.itwbuildex.com SAMMYS® FOR WOOD - Vertical Application MANUFACTURED U.S.A. 5 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETENot less than 2” nominal width (1-1/2”) up to 3-1/2” pipe; not less than 3” (2-1/2”) nominal width 4” & 5” pipe Minimum 2-1/2” from bottom for branch lines. Minimum 3” from bot- tom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Floor Joist Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) Box Qty Case Qty HORIZONTAL MOUNT 1/4"8019957 SWG 200 1/4 x 2"1725 (Fir)25 125 3/8"8020957 SWG 10 1/4 x 1"622 (Fir)300 25 125 3/8"8021957 SWG 20 1/4 x 2"1725 (Fir)1050 25 125 3/8"8073925 SWG 20-SS 1/4 x 2"1725 (Fir)850 25 125 3/8"*8022925 SWG 25-380 3/8 x 2-1/2"2249 (Fir)1500 25 125 3/8"8023925 SWG 30 1/4 x 3"1884 (Fir)25 125#14 SW Red Nut Driver Part # 8114910 • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Box Qty Case Qty SWIVEL MOUNT 3/8"8139957 SH-GST 20 1/4 x 2"1257 (Fir)1050 1475 25 125 3/8"*8269957 SH-GST/CST 20 5/16 x 1-3/4” 1903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 1500 850 @ 45°25 125 1/2”8303957 SH-GST/CST 2.0 5/16 x 1-3/4” 903 Dim. Lumber 1406 @ 45°off vertical Dim. Lumber 25 125 #14 Black Nut DriverPart # 8113910 • Eliminates distortion of threaded rod. • Accommodates up to 3 ½” x 12 pitch roof. • Allows 17° deflection from vertical. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Application Product Features Application Product Features Composite / Truss Consult truss manufacturer for recommended installation point. *Pre-drilling may be required for Model SWG 25-380. Tool available on page 11. Watch a video demonstration atwww.itwbuildex.com SIDEWINDER® FOR WOOD - Horizontal Application SAMMYS SWIVEL HEAD™ FOR WOOD - Swivel Application #14 SH Orange Nut DriverPart # 8273910 * May require pre-drilling; consult joist manufacturer. * May require pre-drilling; consult joist manufacturer. 6 For the most up to date information, visit www.itwbuildex.com Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thick Max Thick Box Qty Case Qty VERTICAL MOUNT 1/4"8024957 DSTR 100 *1/4-20 x 1" TEKS 3 1510 (20 ga.).036"-20 ga 3/16"25 125 1/4"8025957 DST 100 1/4-14 x 1" TEKS 3 446 (20 ga.).036"-20 ga 3/16"25 125 1/4"8026957 DST 150 1/4-14 x 1-1/2" TEKS 3 970 (16 ga.).036"-20 ga 3/16"25 125 1/4"8027957 DST 200 1/4-14 x 2" TEKS 3 446 (20 ga.).036”-20 ga 3/16”25 125 1/4"8030957 TEK 500 12-24 x 1-1/2" TEKS 5 3125 (3/16").188”-3/16”1/2"25 125 3/8"8038957 DSTR 1 *1/4-20 x 1" TEKS 3 1510 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8037957 DSTR 1-1/2 *12-24 x 1-1/2" TEKS 5 1510 (3/16")1500 1475 .060”-16 ga.1/2"25 125 3/8"8039957 DSTR 516 *5/16-18 x 1-1/4" TEKS 3 2200 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8040957 DST 10 1/4-14 x 1" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8077925 DST 10-SS 1/4-14 x 1" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8041957 DST 15 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8078925 DST 15-SS 1/4-14 x 1-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8042957 DST 20 1/4-14 x 2” TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8044957 DST 30 1/4-14 x 3" TEKS 3 446 (20 ga.) 970 (16 ga.).036"-20 ga 3/16"25 125 3/8"8045957 DST 516 5/16-18 x 1-1/4" TEKS 3 1500 (3/16")1500 1475 .125"-1/8"3/16"25 125 3/8"8046957 TEK 50 12-24 x 1-1/2" TEKS 5 3125 (3/16")1500 1475 .250”-1/4”1/2"25 125 1/2"8031925 DST 2.0 1/4-14 x 2" TEKS 3 446 (20 ga.) 970 (16 ga.).188"-3/16"1/4"25 125 1/2"8033925 DSTR 1.0 *1/4-20 x 1" TEKS 3 1510 (20 ga.).036"-20 ga 3/16"25 125 1/2"8034925 DSTR 5.16 *5/16-18 x 1-1/4" TEKS 3 2220 (20 ga.).036"-20 ga 3/16"25 125 1/2"8035925 DST 5.16 5/16-18 x 1-1/4" TEKS 3 1500 (3/16").125"-1/8"3/16”25 125 1/2"8036925 TEK 5.0 12-24 x 1-1/2" TEKS 5 3125 (3/16").188"-3/16"1/2"25 125 #14 Black Nut Driver Part # 8113910 #14 SW Red Nut Driver Part # 8114910 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. • Made with Teks® self-drilling fasteners - no pre-drilling required. • Installs into steel range from 20 gauge – 1/2” thicknesses. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Manufactured in the U.S.A. SAMMYS® FOR STEEL Watch a video demonstration atwww.itwbuildex.com Application Product Features SAMMYS® FOR STEEL - Vertical Application *Includes retaining nut MANUFACTURED U.S.A. 7 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETEApprovals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thick Max Thick Box Qty Case Qty SWIVEL MOUNT 3/8"8137957 SH-DSTR 1*1/4-20 X 1” TEKS 3 3220 (3/16”)1500 1475 .035”3/16”25 125 3/8"8268957 SH-TEK 50 12-24 x 1-3/4" TEKS 5 2368 (1/2" steel Vertical) 1306 (45° off Vertical) 2281 (3/16” HSS) 1585 (3/16” HSS 45° off Vertical) 1500 (Vertical) 850 (45° off Vertical) 4" 2-1/2” 3/16"1/2"25 125 1/2”8270957 SH-TEK 5.0 12-24 x 1-3/4” TEKS 5 2368 (1/2” steel Vertical) 1306 (45° off Vertical) 2281 (3/16” HSS) 1585 (3/16” HSS 45° off Vertical) 3/16"1/2"25 125 #14 Black Nut DriverPart # 8113910 Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) UL Test Load (lbs) FM Test Load (lbs) Min Thickness Max Thickness Box Qty Case Qty HORIZONTAL MOUNT 1/4"8047957 SWD 100 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 1/4"8049957 SWDR 100 *1/4-20 x 1" TEKS 3 1900 (20 ga.).036"-20 ga 3/16"25 125 3/8"8050957 SWD 10 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8080925 SWD 10-SS 1/4-14 x 1" TEKS 3 1477 (16 ga.).060"-16 ga 3/16"25 125 3/8"8052957 SWD 20 1/4-14 x 2" TEKS 3 1477 (16 ga.).060"-16 ga 3/16”25 125 3/8"8055957 SWDR 1 *1/4-20 x 1" TEKS 3 1900 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8054957 SWDR 1-1/2 *12-24 x 1-1/2" TEKS 5 2375 (3/16")1500 1475 .188"-3/16"1/2"25 125 3/8"8056957 SWDR 516 *5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.)1500 1475 .036"-20 ga 3/16"25 125 3/8"8057957 SWT 15 12-24 x 1-1/2" TEKS 5 2375 (3/16").188"-3/16"1/2"25 125 #14 SW Red Nut Driver Part # 8114910 *Includes retaining nut • Made with Teks® self-drilling fasteners - no pre-drilling required. • Installs into steel range from 20 gauge – 1/2” thicknesses. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Saves time from traditional methods. • Reduces installation costs. • Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. • Manufactured in the U.S.A. • Eliminates distortion of threaded rod in sloped roof applications. • Accommodates 3-1/2 x 12 pitch. • Installs into angled z-purlin; allows threaded rod to hang plumb. • Allows 17° deflection from vertical. • Manufactured in the U.S.A. *Does not comply with ROHS requirements / Includes retaining nut Application Product Features SAMMYS SWIVEL HEAD™ FOR STEEL - Swivel Application SIDEWINDER® FOR STEEL - Horizontal Application Application Product Features #14 SH Orange Nut DriverPart # 8273910 Watch a video demonstration atwww.itwbuildex.com Watch a video demonstration atwww.itwbuildex.com 8 For the most up to date information, visit www.itwbuildex.com SAMMY X-PRESS® - Vertical Application Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) FM Min Thick Max Thick Box Qty Case Qty Application VERTICAL MOUNT 1/4"8181922 XP 200 Sammy X-Press 200 1146 (22 ga)185 (Luminaire) 250 (Luminaire) .027" .056”.125”25 125 Metal Deck 3/8"8150922 XP 20 Sammy X-Press 20 1146 (22 ga) 850 (2½" Pipe) 185 (Luminaire) 250 (Luminaire) 283 (Conduit & Cable) .027" .027” .056” .029” 940 (2" Pipe) 1475 (4” Pipe) .029” .104” .125”25 125 Metal Deck 3/8"8153922 XP 35 Sammy X-Press 35 1783 (16 ga) 1500 (4" Pipe) 185 (Luminaire) 250 (Luminaire) 416 (Conduit & Cable) .060” .029” .056” .059” 940 (2" Pipe) 1475 (4” Pipe) .029” .104”.125”25 125 Purlin 3/8"8150922 XP 20 Sammy X-Press 20 1146 (22 ga)850 (2½ Pipe) Pre-Pour Structural Concrete@ 3000 psi Post-Pour Range II LWC≤ 35 PCF (lbs/ft³) 25 125 Metal Deck (Pre-Pour) Metal Deck (Post-Pour) SAMMY X-PRESS® Post-Pour Range II LWC≤ 35 PCF (lbs/ ft³) Pre-Pour Structural Concrete @ 3000 psi Installs into Metal Deck, Purlin, or Tubular Steel • The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or purlin (22 ga. - 1/8”). • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features • The Sammy X-Press Sidewinder expands to provide horizontal attachment in: - 16 ga - 3/16” steel - purlin, tubular steel. • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. (SWXP) Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) Max Thick Box Qty Case Qty Application HORIZONTAL MOUNT 3/8"8293957 SWXP 35 Sidewinder X-Press 35 1798 (16 ga) 1250 (3½" Pipe) 80 (Luminaire) 416 (Conduit & Cable) .059”.125”25 125 Purlin Watch a video demonstration atwww.itwbuildex.com Application Product Features SAMMY X-PRESS SIDEWINDER™ - Horizontal Application (XP) MANUFACTURED U.S.A. 9 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE• The Sammy X-Press Swivel allows you to hang plumb in extreme roof pitches: - 89° in z-purlin - 45° in metal deck for 12/12 pitch • Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. • Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A.(SXP) Installs into Metal Deck, Purlin, or Tubular Steel Approvals Rod Size Part Number Model Description Ultimate Pullout (lbs) UL Test Load (lbs) UL Min Thick FM Test Load (lbs) FM Min Thick Max Thick Box Qty Case Qty Application SWIVEL MOUNT 3/8”8294922 SXP 20 Swivel X-Press 20 1061 (22 ga Vert) 829 (45° Off Vert) 750 (2” Pipe) 170 Vertical (Luminaire) 80 @ 45° (Luminaire) 283 Vertical (Conduit & Cable) 233 @ 45° (Conduit & Cable) .029” 635 (2” Pipe).029”.125”25 125 Metal Deck 3/8"8295922 SXP 35 Swivel X-Press 35 1675 (16 ga Vert) 1558 (89° Off Vert) 1250 (3-1/2" Pipe) 250 Vertical (Luminaire) 80 @ 90° (Luminaire) 500 Vertical (Conduit & Cable) 333 @ 89° (Conduit & Cable) .059” 635 (2" Pipe).029”.125”25 125 Purlin 1/2”8272957 SXP 2.0 Swivel X-Press 2.0 1061 (22 ga Vert) 829 (45° Off Vert).027” .125”25 125 Metal Deck 1/2"8271957 SXP 3.5 Swivel X-Press 3.5 1675 (16 ga Vert) 1558 (89° Off Vert).060".125”25 125 Purlin • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features *Tool Includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64” Drill Bit. Part Number Model Description Qty 8194910 UXPIT*Universal X-Press It Tool 1 8152910 XPDB 25/64" Drill Bit 1 SAMMY X-PRESS IT® Installation Tool • The Sammy X-Press expands to provide direct vertical attachment in: - metal deck (22-16 gauge) - z-purlin (18-16 gauge) • Manufactured in the U.S.A. Watch a video demonstration atwww.itwbuildex.com Application Product Features • Less jobsite material needed. • No retaining nut required. • Provides design flexibility. • Manufactured in the U.S.A. SAMMY X-PRESS SWIVEL™ - Swivel Application 10 For the most up to date information, visit www.itwbuildex.com SAMMYS® FOR CONCRETE - Vertical Application Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* FM Test Load (lbs) Box Qty Case Qty VERTICAL MOUNT 1/4"8058957 CST 200 5/16 x 1-3/4"2400 25 125 3/8"8059957 CST 20 5/16 x 1-3/4"2400 1475 25 125 3/8"8145925 CST 20-SS 5/16 x 1-3/4"2400 25 125 1/2"8060925 CST 2 5/16 x 1-3/4"2400 25 125 #14 BlackNut DriverPart # 8113910 #14SW Red Nut DriverPart # 8114910 • Easy two step process (Drill hole & drive Sammys concrete anchor). • ¼” pre-drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Manufactured in the U.S.A. * Tested in 3000 PSI concrete Application Product Features SAMMYS® FOR CONCRETE Watch a video demonstration atwww.itwbuildex.com SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* FM Test Load (lbs) Box Qty Case Qty HORIZONTAL MOUNT 1/4"8062957 SWC 200 5/16 x 1-3/4"2450 25 125 3/8"8061957 SWC 20 5/16 x 1-3/4"2450 1475 25 125 #14SW Red Nut DriverPart # 8114910 • Easy two step process (Drill hole & drive Sammys concrete anchor). • ¼” pre-drilled pilot hole required. • Concrete Installation Tool available for a one tool installation process. • Manufactured in the U.S.A. * Tested in 3000 PSI concrete Application Product Features Watch a video demonstration atwww.itwbuildex.com SIDEWINDER® FOR CONCRETE - Horizontal Application MANUFACTURED U.S.A. 11 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE(a) or (g)(d)(h) (b) (c) Rotary Hammer Drill into concrete Part Number Description Each Qty 8122910 Concrete Installation Kit (a) Kit includes the following items: 8113910 #14 Black Nut Driver (b)1 8114910 #14 SW Red Nut Driver (c)1 8116910 #250 Bit (1/4") (d)1 8117910 SDS Bit (1/4") (e)1 8118910 7/32 Wood Bit (f)1 8120910 HEX 250 Bit Receiver (1/4") (g)1 8098910 SL 250 Sleeve (h)1 8121910 SDS B250 Bit Receiver (1/4”)*1 *Only sold separately - not included in kit. or (e)(h) (b) (c) Hammer Drill into concrete Application CONCRETE / WOOD INSTALLATION KIT Approvals Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)* Box Qty Case Qty SWIVEL MOUNT 3/8"8269957 SH-GST/CST 20 5/16 x 1-3/4" 2537 in 3000 psi concrete 1459 @ 45°off vertical in 3000 psi concrete 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete 25 125 1/2”8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 2537 in 3000 psi concrete 1459 @ 45°off vertical in 3000 psi concrete 2852 in 6000 psi concrete 1636 @ 45°off vertical in 6000 psi concrete 25 125 * Tested in 3000 PSI concrete Application Product Features #14 SH Orange Nut DriverPart # 8273910 SAMMYS SWIVEL HEAD™ FOR CONCRETE - Swivel Application • Installs vertically and swivels up to 89° in wood & concrete structures. • Eliminates distortion of threaded rod. • 1/4” pre-drilled pilot hole required. • Concrete installation tool available for a one piece installation process. • Manufactured in the U.S.A. Note: UL Listed for wood - see page 5 12 For the most up to date information, visit www.itwbuildex.com SAMMY TOGGLE for Drywall/Concrete Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs)Box Qty Case Qty 1/4"8063925 SST 300 1/4 x 3"450 (Lath & Plaster) 404 (2 Layers 5/8 Rock)25 125 3/8"8064925 SST 30 1/4 x 3"450 (Lath & Plaster) 404 (2 Layers 5/8 Rock)25 125#14 Black Nut DriverPart # 8113910 Pre-Cast Hollow Core Concrete 1. Pre-drill a 5/8” hole with a regular drill or hole saw. 2. Insert SST screw into #14 black nut driver. With wing nut and washer on bolt, insert wing nut through surface, and begin installation. 3. When bolt is secure and nut driver spins free, stop drill motor and remove. 4. SST screw is now ready to receive 1/4”, 3/8”, or Metric all thread rod or bolt stock. Approvals Substrate Part Number Model Point Description Overal Total Length Ultimate Pullout (lbs) Max Gauge ICC Test Load (lbs) Box Qty Case Qty ICC STEEL 8107957 CWSD 1*Teks 1/4 x 1"2”472 (20 ga)16 ga.170 (20 ga.)25 125 ICC STEEL WOOD 8190957 CWSD 15*Gimlet Teks 1/4 x 1-1/2"2-3/4”472 (20 ga) 1393 (Fir)20 ga.170 (20 ga.)25 125 ICC STEEL 8108957 CWSD 2*Teks 1/4 x 2"3-1/4”472 (20 ga)16 ga.170 (20 ga.)25 125 ICC 8110910 CWIT Installation Tool 1CWIT Installation ToolPart # 8110910 Use the Speedy Pole Tool™ for easy installation of ceiling screws without ladders or scaffolding! (see pg 13 for details) • 3/16” eyelet to accommodate common wire size. • ICC approvals can be found at www.itwbuildex.com under Evaluation Report # ER-5367. * Does not comply with ROHS requirements Application Installation Steps Application Product Features CEILING SCREWS SAMMYS TOGGLE™ ACCESSORIES To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETE13 Part Number Model Ea. Qty 8130910 Spot Rite Level 1 • 1/2”, 3/4”, and 1” threading • Magnetic strip for ease of use • Pocket Sized • Lightweight • 3-vial design for measurement of 0º, 45º, and 90º angles • Complies with NFPA 13 Code Changes. • Flashing for dry pendant sprinklers subject to extreme temperature changes. • One piece construction is easy to install. • Pipe diameter markings ensure accurate fit. • EPDM temperature range of -65°F to +250°F. Part Number Description Pipe Outside Diameter Dektite Base Diameter Dektite Height Box Qty 4001910 Mini 1/4” - 1-1/8”3-1/2”1-3/4”20 4003910 1 1/4” - 2”4-3/4”3”10 4004910 2 1-3/4” - 3-1/4”6-1/4”4”10 DEKTITE® PIPE FLASHING Application Product Features SPOT-RITE LEVEL™ (Items not sold seperately) Product Features • The Pole Tool and Universal Socket Kit provide easy and safe installation for: - Sammys - Jack Chain - Threaded Rod - Wire - Pencil Rod - Screws - Ceiling Screws • Ideal for retrofit and hard-to-reach projects in wood and steel. Part Number Description Box Qty 8123910 Pole Tool 6' (3' - 6')1 8124910 Pole Tool 12' (4' - 12')1 8125910 Pole Tool 18' (6' - 18')1 8126910 Pole Tool 24' (8' - 24')1 Speedy Pole Tool Installation (specify choice when ordering pole tool) 8127910 Sammys Socket Driver 1 8128910 Ceiling Wire Socket Driver for wire and chain 1 8129910 Universal Pole Tool Socket Kit 1 • Adaptor Plug (a) • Socket Driver for SAMMYS (b) • Socket Driver for Ceiling Wire Screws (c) • Socket Driver for 1/4” Standard Nut Drivers (d) • Stud Plug for Viper or Ladd Powder Actuated Attachment (e)(c) (b) (d) (e)(a) SPEEDY POLE TOOL™ & UNIVERSAL SOCKET KIT Universal Pole Tool Socket Kit (8129910) Includes:Product Features Watch a video demonstration atwww.itwbuildex.com Part Number Model Rod Size Mount Direction UL Max Pipe Size UL Test Load (lbs)UL Min Wood Thickness FM Max Pipe Size FM Test Load (lbs)FM Min Wood Thickness SAMMYS FOR WOOD - PIPE HANGER 8007957 GST 10 3/8”Vertical CPVC 1-1/2”300 1-1/2” 8020957 SWG 10 3/8”Horizontal CPVC 1-1/2”300 1-1/2” 8008957 GST 20 3/8”Vertical 2-1/2”850 1-1/2”4”1475 1-1/2” 8068925 GST 20-SS 3/8”Vertical 2-1/2”850 1-1/2” 8010957 GST 30 3/8”Vertical 4”1500 1-1/2”4”1475 1-1/2” 8009925 GST 25-380 3/8”Vertical 4”1500 1-1/2” 8022925 SWG 25-380 3/8”Horizontal 3-1/2” - 4”*1500 1-1/2” 8021957 SWG 20 3/8”Horizontal 2-1/2” - 3”**1050 1-1/2” 8073925 SWG 20-SS 3/8”Horizontal 2-1/2”850 1-1/2” 8269957 SH-GST/CST 20 3/8”45° Angle off Vertical 2-1/2”850 1-1/2” 8269957 SH-GST/CST 20 3/8”45° Angle off Vertical 4”1500 1-1/2” 8139957 SH-GST 20 3/8”17° Angle off Vertical 3”1050 1-1/2”4”1475 1-1/2” SAMMYS FOR STEEL - PIPE HANGER Min Steel Thick Max Steel Thick 8038957 DSTR 1 3/8”Vertical 4”1500 .035”4”1475 .105” 8037957 DSTR 1-1/2 3/8” Vertical 4”1500 .035”4”1475 .105” 8039957 DSTR 516 3/8”Vertical 4”1500 .037”4”1475 .105” 8045957 DST 516 3/8”Vertical 4”1500 .188”4”1475 .188” 8046957 TEK 50 3/8”Vertical 4”1500 .250”4”1475 .188” 8055957 SWDR 1 3/8”Horizontal 4”1500 .037”4”1475 .060” 8056957 SWDR 516 3/8”Horizontal 4”1500 .037”4”1475 .060” 8054957 SWDR 1-1/2 3/8”Horizontal 4”1500 .037”4”1475 .060” 8137957 SH-DSTR 1 3/8”17° Angle off Vertical 4”1500 .035”4”1475 .105” 8268957 SH-TEK 50 3/8”Vertical 2-1/2”850 70° Angle off Vertical 4”1500 8150922 XP 20 3/8”Vertical 2-1/2”850 .027”2”940 .029” 4”1475 .105” 8153922 XP 35 3/8”Vertical 4”1500 .060”2”940 .029” 4”1475 .125” 8294922 SXP 20 3/8”Vertical or up to 45°2”750 .027”2”635 .029” 8295922 SXP 35 3/8”Vertical or up to 89°3-1/2”1250 .060”2”635 .029” 8293957 SWXP 35 3/8”Horizontal 3-1/2”1250 .060” SAMMYS FOR CONCRETE - PIPE HANGER 8059957 CST 20 3/8”Vertical 4”1475 3000 8061957 SWC 20 3/8”Horizontal 4”1475 3000 8150922 XP 20 3/8”Vertical 2-1/2”850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8”Vertical 2-1/2”850 Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) 14 Part Number Model Rod Size Mount Direction UL Load Rating (lbs)UL Min Steel Thickness SAMMYS FOR STEEL - LUMINAIRE FITTING 8150922 XP 20 3/8”Vertical 185 .027” 250 .035” 8153922 XP 35 3/8”Vertical 185 .027” 250 .035” 8181922 XP 200 1/4”Vertical 185 .027” 250 .035” 8294922 SXP 20 3/8”Vertical 170 .027” 45°80 .027” 8295922 SXP 35 3/8”Vertical 250 .060” 90°80 .060” 8293957 SWXP 35 3/8”Horizontal 80 .060” Sheet Steel Gauges Gauge No.22 ga.20 ga.18 ga.16 ga.14 ga.12 ga.1/8”3/16”1/4” Nominal Decimal Equivalent .030”.036”.048”.060”.075”.105”.125”.188”.250” Part Number Model Rod Size Mount Direction UL Load Rating (lbs)UL Min. SteelThickness Listed Application SAMMYS FOR STEEL - CONDUIT, TUBING, AND CABLE 8150922 XP 20 3/8”Vertical 283 .027”Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8”Vertical 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8”Vertical 283 .027”Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8”Vertical 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8”Horizontal 500 .060”Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4” or 3/8”Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Complies w/ NEC Standards *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2” *SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4” **SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2” **SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3” UL compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. APPROVALS For the most up to date information, visit www.itwbuildex.com 15 To find a distributor near you, call 800-BUILDEX STEELSTEELWOODAPPROVALSACCESSORIESCONCRETEPart NumberModelRod SizeMount DirectionUL Max Pipe SizeUL Test Load (lbs)UL Min Wood ThicknessFM Max Pipe SizeFM Test Load (lbs)FM Min Wood Thickness SAMMYS FOR WOOD - PIPE HANGER 8007957GST 103/8”VerticalCPVC 1-1/2”3001-1/2” 8020957SWG 103/8”HorizontalCPVC 1-1/2”3001-1/2” 8008957GST 203/8”Vertical2-1/2”8501-1/2”4”14751-1/2” 8068925GST 20-SS3/8”Vertical2-1/2”8501-1/2” 8010957GST 303/8”Vertical4”15001-1/2”4”14751-1/2” 8009925GST 25-3803/8”Vertical4”15001-1/2” 8022925SWG 25-3803/8”Horizontal3-1/2” - 4”*15001-1/2” 8021957SWG 203/8”Horizontal2-1/2” - 3”**10501-1/2” 8073925SWG 20-SS3/8”Horizontal2-1/2”8501-1/2” 8269957SH-GST/CST 203/8”45° Angle off Vertical2-1/2”8501-1/2” 8269957SH-GST/CST 203/8”45° Angle off Vertical4”15001-1/2” 8139957SH-GST 203/8”17° Angle off Vertical3”10501-1/2”4”14751-1/2” SAMMYS FOR STEEL - PIPE HANGERMin Steel ThickMax Steel Thick 8038957DSTR 13/8”Vertical4”1500.035”4”1475.105” 8037957DSTR 1-1/23/8” Vertical4”1500.035”4”1475.105” 8039957DSTR 5163/8”Vertical4”1500.037”4”1475.105” 8045957DST 5163/8”Vertical4”1500.188”4”1475.188” 8046957TEK 503/8”Vertical4”1500.250”4”1475.188” 8055957SWDR 1 3/8”Horizontal4”1500.037”4”1475.060” 8056957SWDR 5163/8”Horizontal4”1500.037”4”1475.060” 8054957SWDR 1-1/23/8”Horizontal4”1500.037”4”1475.060” 8137957SH-DSTR 13/8”17° Angle off Vertical4”1500.035”4”1475.105” 8268957SH-TEK 503/8”Vertical2-1/2”850 70° Angle off Vertical4”1500 8150922XP 203/8”Vertical2-1/2”850.027”2”940.029” 4”1475.105” 8153922XP 353/8”Vertical4”1500.060”2”940.029” 4”1475.125” 8294922SXP 203/8”Vertical or up to 45°2”750.027”2”635.029” 8295922SXP 353/8”Vertical or up to 89°3-1/2”1250.060”2”635.029” 8293957SWXP 353/8”Horizontal3-1/2”1250.060” SAMMYS FOR CONCRETE - PIPE HANGER 8059957CST 203/8”Vertical4”14753000 8061957SWC 203/8”Horizontal4”14753000 8150922XP 203/8”Vertical2-1/2”850Pre-Pour Structural @ 3000psi 8150922XP 203/8”Vertical2-1/2”850Post-Pour Range II LWC ≤ 35 PCF (lbs/ft3) SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188” and .118”. Subsequent testing was done for z-purlin applications in May 1997 using (.037”) or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030”) or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric ProductsMetric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for SeismicPlease visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8” smaller than root diameter of fastener. Consult the table below: To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC StandardsAll UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings / FM ApprovalsUL and FM reports are available at www.itwbuildex.com Technical DrawingsTechnical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Manufactured in the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 Model Root Diameter Hole Size GST 20 .182”1/8” GST 25-380 .280”7/32” SWG 20 .182”1/8” SWG 25-380 .280”7/32” MANUFACTURED U.S.A. Product information Hilti, Inc. (USA) 1-800-879-8000 I www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca Hilti. Outperform. Outlast. High-performance intumescent firestop sealant FS-ONE MAX Applications ■For effectively sealing most common through penetrations in a variety of base materials ■For use on concrete, masonry and drywall ■Mixed and multiple penetrations ■Metal pipe penetrations: copper, steel and EMT ■Insulated metal pipe penetrations: steel and copper ■Plastic pipe penetrations: closed or vented Advantages ■US-produced: “Buy American” compliant ■One product for a variety of common through penetrations ■Cost-effective, easy-to-use solution ■Water-based and paintable ■Industry-leading VOC results ■Ethylene glycol-free 12/16 DBSOrder Designation Package Content Item number FS-ONE MAX 20oz foil (3 case + disp)1x Foil pack dispenser manual CS 270-P1, 75x Firestop sealant FS-ONE MAX 20 oz foil 3530252 FS-ONE MAX 10oz tube (1 case)12x Firestop sealant FS-ONE MAX 10 oz cartridge 3530249 FS-ONE MAX 5 gallon (18 pails)18x Firestop sealant FS-ONE MAX 5 gallon pail 3530263 FS-ONE MAX 20oz foil (1 case)25x Firestop sealant FS-ONE MAX 20 oz foil 3530250 FS-ONE MAX 20oz foil (3 cases)75x Firestop sealant FS-ONE MAX 20 oz foil 3530251 FS-ONE MAX 20oz Foil-Pallet 600x FSONE-MAX 20 oz foil, 290x Bulk Shipping Condition 3534713 FS-ONE MAX 10 oz cartridge 2101531 FS-ONE MAX 5 gallon pail 2101533 Technical data Chemical basis Water-based acrylic dispersion Approx. Density 84.3 lb/ft³ Color Red Application temperature range 41 - 104 °F Approx. cure time1)4 mm/3 days Temperature resistance range -4 to 212 °F Mold and mildew performance Class 0 (ASTM G21-96) Mold and mildew resistance Yes Surface burning characteristics UL 723 (ASTM E84) Flame spread: 0 Smoke development: 10 Tested in accordance with UL 1479, ASTM E814, ASTM E84, CAN/ ULC-S115, ASTM G21, ASTM E90 California State fire marshal approval CSFM Listing 4485-1200:0108 for FS-ONE MAX Intumescent Firestop Sealant Expansion ratio (unrestricted, up to)1:5 1) at 75°F/24°C, 50% relative humidity Mold and mildew resistant Chemical resistant FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 PRODUCT DESCRIPTION The Series 7C7 Air Maintenance/Compressor assembly consists of a riser-mounted compressor, Series 757P Air Maintenance Device and flexible hoses for installation. It is designed to ensure the valve system can achieve operational air pressure within 30 minutes of discharge, in accordance with NFPA 13 requirements (7.2.6.2.2). The Series 757P Air Maintenance Device is UL Listed and FM Approved. The Series 7C7 Assembly is available with 1/6, 1/3 and 1/2 horsepower compressors depending upon the system requirements. For FireLock NXT™ Series 768 Dry Valves, Series 769 Deluge and Preaction Valves, Series 764 Alternate Valves. Note: The Series 7C7 Air Maintenance/Compressor Assembly is designed for systems that do not require an accelerator to achieve the required system pressure performance. If an accelerator is required, a tank-mounted compressor with a regulated air maintenance device should be used. COMPRESSOR CAPACITIES The engineer/system designer is responsible for sizing the compressor so that the entire system is charged to the required air pressure within NFPA guidelines (30 minutes). DO NOT oversize the compressor to provide more airflow. An oversized compressor will slow down or possibly prevent valve operation. Hp Nominal AC Voltage/Hz (+/- 10%) Pressure psi/Bar Time Minutes Capacity WITH AutoVent gallons/m3 Capacity WITHOUT AutoVent gallons/m3 Amp Draw 1/6 110/60 18 30 175 275 2.1 Amps1.2 0.7 1.1 1/3 110/60 18 30 375 525 4.4 Amps 1.2 1.4 2.0 1/3 220/50 18 30 160 235 1.2 0.6 0.9 1/3 220/50 18 60 450 660 1.2 1.7 2.5 1/3 220/60 18 30 370 400 1.51.2 1.4 1/2 110/50 18 30 660 670 6.6 Amps1.2 2.5 2.5 1/2 110/60 18 30 780 830 3.11.2 3.0 3/4 220/50 18 30 600 675 3.8 Amps 1.2 2.3 2.5 3/4 220/60 18 30 700 775 2.91.2 2.7 3/4 220/50 18 60 1200 1350 5.01.2 4.5 3/4 220/60 18 60 1375 1525 5.81.2 5.2 NOTE: Refer to the charts on the following pages for minimum required fill capacities to 13 psi/0.9 Bar. Low air alarms will clear at 13 psi/0.9 Bar. In addition, these charts contain higher capacities to 18 psi/1.2 Bar that are not shown in the table above. 30.22_1 Air Maintenance/ Compressor Assembly SERIES 7C7 30.22FIRE PROTECTION PRODUCTS – DEVICES JOB/OWNER CONTRACTOR ENGINEER System No. ______________________________Submitted By ____________________________Spec Sect _______________ Para ___________ Location ________________________________Date ___________________________________Approved _______________________________ Date ___________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G SERIES 7C7 ASSEMBLY DIMENSIONS Series 7C7 - 1/3HP Compressor Pipe Size A B C D 1 1/2”14.53 5.00 6.55 15.38 2”14.78 5.00 6.55 15.38 2 1/2” & 76.1 15.04 5.00 6.55 15.38 3”15.36 5.00 6.55 15.38 4”15.88 5.00 6.55 15.38 6” & 165.5 16.98 5.00 6.55 15.38 8”18.02 5.00 6.55 15.38 Series 7C7 - 1/3HP Compressor Series 7C7 - 1/6HP Compressor Series 7C7 - 1/6HP Compressor Pipe Size A B C D 1 1/2”14.53 4.60 6.55 15.38 2”14.78 4.60 6.55 15.38 2 1/2” & 76.1 15.04 4.60 6.55 15.38 3”15.36 4.60 6.55 15.38 4”15.88 4.60 6.55 15.38 6” & 165.5 16.98 4.60 6.55 15.38 8”18.02 4.60 6.55 15.38 A B C D A B C DD A B C Series 7C7 - 1/2HP Compressor Pipe Size A B C D 1 1/2”14.5 4.8 6.55 15.54 2”14.77 4.8 6.55 15.54 2 1/2” & 76.1 15.03 4.8 6.55 15.54 3”15.36 4.8 6.55 15.54 4”15.94 4.8 6.55 15.54 6” & 165.5 16.98 4.8 6.55 15.54 8”18.01 4.8 6.55 15.54 Series 7C7 - 1/2HP Compressor 30.22 30.22_2 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G SERIES 7C7 ASSEMBLY PERFORMANCE (1/2 HP Compressor) - For use with FireLock NXT Series 768 Dry, Series 764 Alternate wet/dry and 769 Deluge and Preaction systems. 18 psi 13 psi System Size (gallons)Time (minutes)Estimated Time to Reach Various Pressures -Series 7C7 with 1/2-hp (110 VAC, 50 Hz) Compressor and Auto Vent 0 5 10 15 20 25 30 35 40 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 45 50 18 psi 13 psi System Size (gallons)Time (minutes)Estimated Time to Reach Various Pressures -Series 7C7 with 1/2-hp (110 VAC, 60-Hz) Compressor and Auto Vent 0 5 10 15 20 25 30 35 40 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 0 10 20 30 40 50 18 psi 13 psi System Size (gallons)Time (minutes)Estimated Time to Reach Various Pressures -Series 7C7 with 1/2-hp (110 VAC, 50 Hz) Compressor and No Auto Vent 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 0 10 20 30 40 50 18 psi 13 psi System Size (gallons)Time (minutes)Estimated Time to Reach Various Pressures -Series 7C7 with 1/2-hp (110 VAC, 60 Hz) Compressor and No Auto Vent 25 75 125 175 225 275 325 375 425 475 525 575 625 675 725 775 825 875 925 975 1025 1075 1125 1175 1225 30.22 30.22_3 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G SERIES 7C7 ASSEMBLY PERFORMANCE (1/3 HP Compressor) - For use with FireLock NXT Series 768 Dry, Series 764 Alternate wet/dry and 769 Deluge and Preaction systems. 0 10 20 30 40 50 60 System Size (cubic meters)Time (minutes)0.6 1.0 1.4 1.80.2 2.2 2.6 3.0 1.2 Bar 0.9 Bar Estimated Time to Reach Various Pressures - 220-volt OptionSeries 7C7 with 1/3-hp (220-240 VAC, 50-Hz) Compressor and Auto Vent 0 10 20 30 40 50 60 System Size (cubic meters)Time (minutes)0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 1.2 Bar 0.9 Bar Estimated Time to Reach Various Pressures - 220-volt OptionSeries 7C7 with 1/3-hp (220-240 VAC, 60-Hz) Compressor and Auto Vent 0 10 20 30 40 50 60 70 Estimated Time to Reach Various Pressures - 220-volt OptionSeries 7C7 with 1/3-hp (220 - 240 VAC, 50 Hz) Compressor and No AutoVent Time (minutes)System Size/Volume (cubic meters) 0 0.5 1.0 1.5 2.0 2.5 3.0 1.2 Bar 0.9 Bar 0 10 20 30 40 50 60 Estimated Time to Reach Various Pressures - 220-volt OptionSeries 7C7 with 1/3-hp (220 - 240 VAC, 60 Hz) Compressor and No Auto Vent 0 0.5 1.0 1.5 2.0 2.5 3.0Time (minutes)System Size/Volume (cubic meters) 1.2 Bar 0.9 Bar 0 10 20 30 40 50 60 System Size (Gallons)Time (Minutes)50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 Estimated Time to Reach Various Pressures - Series 7C7 with 1/3-hp (110 VAC) Compressor and Auto Vent 13 psi 18 psi 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 0 10 20 30 18 psi 13 psi Estimated Time to Reach Various Pressures -Series 7C7 with 1/3-hp (110 VAC) Compressor and No Auto Vent System Size (gallons)Time (minutes)NOTE: Refer to the following page for charts reflecting the 220-volt 1/3-hp option. 30.22 30.22_4 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G SERIES 7C7 0 10 20 30 40 50 60 70 System Size (Gallons)Time (Minutes)50 100 150 200 250 300 350 400 Estimated Time to Reach Various Pressures - Series 7C7 with 1/6-hp (110 VAC) Compressor and Auto Vent 13 psi 18 psi 50 100 150 200 250 300 350 400 0 10 20 30 18 psi 13 psi Estimated Time to Reach Various Pressures -Series 7C7 with 1/6-hp (110 VAC) Compressor and No AutoVent System Size (gallons)Time (minutes)ASSEMBLY PERFORMANCE (1/6 HP Compressor) - For use with FireLock NXT Series 768 Dry, Series 764 Alternate wet/dry and 769 Deluge and Preaction systems. 30.22 30.22_5 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G SERIES 7C7 ExPLODED VIEW DRAWING - SERIES 7C7 AIR MAINTENANCE COMPRESSOR ASSEMBLY WITH 1/2-HP COMPRESSOR 1 4 23 6 14 2 3 10 7 14 11 To ActuatorTrim 9 8 5 15 1925 24 18 16 17 12 13 20 21 22 26 Bill of Materials Item Qty. Description 1 1 Compressor 2 1 Mounting Bracket 3 1 Series 757P Air Maintenance Trim Assembly with Pressure Switch 4 1 Stainless Steel Braided Flex Hose (½-inch NPT Male x Female) 5 2 Split Hanger for ½-inch Pipe 6 2 Hose Clamp 7 1 Close Nipple (¼-inch NPT) 8 3 Close Nipple (½-inch NPT) 9 3 90° Female Elbow (½-inch NPT) 10 2 Hex-Head Bolt (⁄ - 16 x ⁄-inch Long) 11 4 Lock Washer (⁄ inch) 12 2 Lock Washer (⁄ inch) 13 4 Hex Nut (¼ - 20 UNC) 14 2 Straight Conduit Connector (½-inch) 15 1 Liquid-Tight Conduit (½ inch x 9½ inches Long) 16 1 14 AWG, 3-Strand Cable (25 inches Long) 17 3 #8 U-Style Wire Connector 18 1 Identication Tag 19 1 Compressor Air Intake Filter 20 1 Nipple (½-inch NPT x 10 inches Long) 21 1 Nipple (½-inch NPT x 4½ inches Long) 22 1 Union (½-inch NPT) 23 1 Reducing Bell (½-inch NPT x ¼-inch NPT) 24 1 14 AWG Grounded Cord with Plug (5½ feet Long)* 25 1 Strain Relief Connector* 26 1 Identication Label* * NOTE: Items 24 - 26 apply only to the CSA version Exaggerated for Clarity 30.22 30.22_6 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G SERIES 7C7 ExPLODED VIEW DRAWING - SERIES 7C7 AIR MAINTENANCE COMPRESSOR ASSEMBLY WITH 1/6-HP COMPRESSOR 1 4 7 5 6 11 13 2 3 8 19 10 To Actuator Trim 16 9 5 12 14 15 17 18 20 21 22 23 2425 26 Bill of Materials Item Qty. Description 1 1 Compressor 2 1 Mounting Bracket 3 1 Series 757P Air Maintenance Trim Assembly with Pressure Switch 4 1 Stainless Steel Braided Flex Hose (½-inch NPT Male x Female) 5 2 Split Hanger for ½-inch Pipe 6 2 Hose Clamp 7 3 90° Female Elbow (½-inch NPT) 8 1 Close Nipple (¼-inch NPT) 9 2 Close Nipple (½-inch NPT) 10 2 Hex-Head Bolt (⁄ - 16 x ⁄-inch Long) 11 3 Hex-Head Bolt (#10 - 32 x ½-inch Long) 12 2 Lock Washer (⁄ inch) 13 3 Lock Washer (#10) 14 1 Identication Tag 15 1 Straight Connector, Flexible Cord 16 1 Connector, Flexible Cord 17 1 Liquid-Tight Conduit (½ inch x 11½ inches Long) 18 3 #8 U-Style Wire Connector 19 1 Reducing Bell (½-inch NPT x ¼-inch NPT) 20 1 Nipple (½-inch NPT x 1½ inches Long) 21 1 Nipple (½-inch NPT x 9 inches Long) 22 1 Union (½-inch NPT) 23 1 Nipple (½-inch NPT x 5 inches Long) 24 1 Identication Label* 25 1 Strain Relief Connector* 26 1 14 AWG Grounded Cord with Plug (5½ feet Long)* * NOTE: Items 24 - 26 apply only to the CSA versionExaggerated for Clarity ExPLODED VIEW DRAWING - SERIES 7C7 AIR MAINTENANCE COMPRESSOR ASSEMBLY WITH 1/3-HP COMPRESSOR 1 4 25 6 23 2 3 7 To Actuator Trim 9 8 5 10 11 12 13 14 15 16 17 18 19 20 21 22 24 26 27 Bill of Materials Item Qty. Description 1 1 Compressor 2 1 Mounting Bracket 3 1 Series 757P Air Maintenance Trim Assembly with Pressure Switch 4 1 Stainless Steel Braided Flex Hose (½-inch NPT Male x Female) 5 2 Split Hanger for ½-inch Pipe 6 2 Hose Clamp 7 1 Close Nipple (¼-inch NPT) 8 2 Close Nipple (½-inch NPT) 9 3 90° Female Elbow (½-inch NPT) 10 4 Hex-Head Bolt (⁄ - 18 x ¾-inch Long) 11 2 Hex-Head Bolt (⁄ - 16 x ⁄-inch Long) 12 4 Lock Washer (⁄ inch) 13 2 Lock Washer (⁄ inch) 14 4 Hex Nut (⁄ - 18) 15 2 Straight Conduit Connector (½ inch) 16 1 Liquid-Tight Conduit (½ inch x 9½ inches Long) 17 2 14 AWG, 3-Strand Cable (25 inches Long) 18 3 #8 U-Style Wire Connector 19 1 Identication Tag 20 1 Reducing Bell (½-inch NPT x ¼-inch NPT) 21 1 Nipple (½-inch NPT x 1½ inches Long) 22 1 Nipple (½-inch NPT x 5½ inches Long) 23 1 Nipple (½-inch NPT x 9½ inches Long) 24 1 Union (½-inch NPT) 25 1 14 AWG Grounded Cord with Plug (5½ feet Long)* 26 1 Strain Relief Connector* 27 1 Identication Label* * NOTE: Items 25 - 27 apply only to the CSA versionExaggerated for Clarity 30.22 30.22_7 FIRE PROTECTION PRODUCTS – DEVICES Air Maintenance/ Compressor Assembly www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G SERIES 7C7 WARNING •Thisproductmustbeinstalledbyanexperienced,trainedinstaller, inaccordancewiththeinstructionsprovidedwitheachvalve.These instructions contain important information. Failuretofollowtheseinstructionsmayresultinseriouspersonalinjury, propertydamage,orvalveleakage. Ifyouneedadditionalcopiesofthisproductliteratureorthevalve installationinstructions,orifyouhaveanyquestionsaboutthesafe installationanduseofthisdevice,contactVictaulicCompany,P.O. Box31,Easton,PA18044-0031USA,Telephone:001-610-559-3300. WARNING WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE ELECTRICAL INFORMATION DANGER •Onlyqualifiedelectriciansshouldconnect incomingpowertotheSeries7C7Air Maintenance/Compressor Assembly. •Toreducetheriskofelectricshock,check theelectricalsourceforpropergrounding. Failuretofollowtheseinstructionscouldresultin deathorseriouspersonalinjury. Ground Connection ELECTRICAL CONNECTION LINE LOAD LINELOAD L1 L2 L 1 T 1 T 2 L 2 T 1 T 2 MOTOR INCOMING POWER SUPPLY(REFERENCE COMPRESSORDATA PLATE) NOTE: NEMA 1 Enclosure - intended only for indoor use Only qualified electricians should make the connection to the incoming power supply. All wiring shall be completed in accordance with requirements of the local authority having jurisdiction and any applicable electrical codes. 30.22 Air Maintenance/ Compressor Assembly 30.22FIRE PROTECTION PRODUCTS – DEVICES For complete contact information, visit www.victaulic.com 30.224847REV G UPDATED 02/2013 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2013 VICTAULIC COMPANY. ALL RIGHTS RESERVED. SERIES 7C7 Reliability, Versatility, Code Compatibility Note: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to oPeN in a range of pressure between 90% and 105% of their rating. the valves are required to CLoSe at a pressure above 80% of that rating. the relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNot be isolated from the system when the system is operational. A relief valve should NeVeR have a shutoff valve or a plug downstream of its outlet. SS-M1011A_V001 · 06/13 TESTa n DRAIN® is a registered trademark of AGF Manufacturing Inc. Model 1011ATESTa n DRaIn® Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve Complies with NFPA 13 and NFPA 13R Requirements • Compact, Single-Handle Ball Valve • Tamper-Resistant Test Orifice and Sight Glasses• 300 PSI rated.• Specifiable orifice sizes: ³⁄• 8" (2.8K), 7⁄16" (4.2K), ½" (5.6K), 17⁄32" (8.0K), 5⁄8" (11.2K, ELO), ¾" (14.0K, ESFR), and K25 Relieves Excess System Pressure caused by Surges or Temperature Changes • Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing• Locking Kit Available• Repair kits are available for all TESTa n DRaIn® valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer (1). Valve and orifice size must be specified when ordering. The AGF Model 1011A TESTa n DRaIn® provides the test and express drain functions for wet fire sprinkler systems on multi-story installations requiring pressure relief (NFPA 13 and NFPA 13R). The Model 1011A features a Model 7000 Pres- sure Relief Valve with drain pipe. The Model 1011A is available in a full range of sizes (¾" to 2") with NPT connections (BSPT available). The Model 7000 Pressure Relief Valve (UL/FM) features a flushing handle and a 175 PSI factory rating (other pressure ratings available). Sizes: ¾"1"1¼"1½"2" Dimensions SIZE A B C D E F G H ¾"79⁄16" (191 mm) 11⁄2" (37.5 mm) 23⁄16" (57 mm) 35⁄8" (93 mm) 33⁄8" (86 mm) 113⁄16" (46 mm) 49⁄16" (117 mm) 63⁄8" (162.5 mm) 1"79⁄16" (191 mm) 11⁄2" (37.5 mm) 23⁄16" (57 mm) 35⁄8" (93 mm) 33⁄8" (86 mm) 113⁄16" (46 mm) 49⁄16" (117 mm) 63⁄8" (162.5 mm) 11⁄4"715⁄16" (201 mm) 111⁄16" (43 mm) 29⁄16" (65 mm) 41⁄4" (108 mm) 35⁄8" (91 mm) 115⁄16" (51 mm) 59⁄16" (141 mm) 71⁄2" (192 mm) 1½"815⁄16" (227 mm) 113⁄16" (45 mm) 31⁄4" (81.5 mm) 51⁄16" (127 mm) 37⁄8" (99 mm) 25⁄8" (67 mm) 81⁄4" (207 mm) 107⁄8" (274 mm) 2"815⁄16" (227 mm) 113⁄16" (45 mm) 31⁄4" (81.5 mm) 51⁄16" (127 mm) 37⁄8" (99 mm) 25⁄8" (67 mm) 81⁄4" (207 mm) 107⁄8" (274 mm) *Available on 1¼" to 2" size units only • **Available on 1½" and 2" size units only Approvals UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM Job Name:__________________________________ Architect: ___________________________________ Engineer: ___________________________________ Contractor: _________________________________ USA Patent # 4741361 and Other Patents Pending Materials Handle ................Steel Stem ...................Rod Brass Ball ......................C.P. Brass Body ...................Bronze Valve Seat ...........Impregnated Teflon® Indicator Plate ....Steel Relief Valve .........Bronze Bypass Fittings ...Brass Bypass Tubing ....Nylobraid Orifice Sizes 3⁄8", 7⁄16", ½", 17⁄32", 5⁄8" ELO*, ¾" ESFR*, and K25** AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com The Model 1011A provides the following… From the 2013 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) – & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow… using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler… Chapter 8.17.4.2.2 The test connection valve shall be accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location… downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler… Chapter 8.17.4.3.2 The trip test connection… with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a wet pipe system shall be provided with a listed relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A listed relief valve of not less than ½" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding rated pressure of the system. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve Model 1011ATESTa n DRaIn® Model 1011A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve Factory Rated at 175 PSI with other setting available TO DRAIN TO DRAIN H F G E A A INLET D B C Model 1011A - Front View Model 1011A - Plan View TO DRAIN TO DRAIN H F G E A A INLET D B C Specifications Size(IP)* ID OD 1/2” .827 2.787 3/4” 1.037 2.997 1” 1.298 3.210 11/4” 1.640 3.580 11/2” 1.900 3.900 2” 2.380 4.450 21/2” 2.900 5.280 3” 3.535 5.925 4” 4.575 6.935 5” 5.655 9.655 6” 6.740 9.820 8” 8.790 13.010 Depth: 3/4 ” Finish: Chrome White 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. Description FPPI Plastic Floor and Ceiling Plates are manufactured from light weight injection molded plastic and are of single piece construction and rustproof. They are suitable for both interior and exterior uses and are highly recommended in corrosive environments. Available in IP sizes 1/2” through 8”. Installation The plastic wall plates may be installed by two methods. The first is by placing the wall plate over the pipe while the pipe is being installed. The second is by splitting the wall plate at the area on the back of the wall plates that has been molded to break apart. Carefully bend the wall plate a this weakened area until fully separated. Then carefully twist the wall plate open just enough to be placed around the pipe. Allow the two ends of the separated wall plate to “spring” back into shape. Slide the wall plate up against the base material to finish the installation. The wall plates should not be painted. Certain chemicals contained in paint may cause the wall plates to deteriorate. WWW.FPPI.COM Plastic Wall Plates Floor/Ceiling 16