04_C400 Utilities Plan Washington Salem 05-09-18UTILITY & DRAINAGE NOTES ALL EXISTING ABANDONED PIPES TO BE CUT & CAPPED AT MAIN. THE LOCATION OF AND SIZE OF BURIED UTILITIES ARE TAKEN FROM THE "EXISTING CONDITION PLAN" BY NORDE-EAST SURVEY, PLAN DATED DECEMBER 7, 2012; AND AS -BUILT PLAN PREPARED BY NECE, THIS PLAN DOES NOT NECESSARILY DEPICT THE EXACT LOCATION AND SIZE OF ALL UTILITIES WHICH MAY EXIST AT THIS TIME INSIDE OR OUTSIDE OF EXISTING OR PROPOSED BUILDINGS, ON THE SUBJECT PROPERTY, WITHIN THE STREET ROW, OR ON ABUTTING LOTS. CITY OF SALEM MUNICIPAL UTILITIES (WATER, SEWER & DRAIN) ARE NOT PART OF DIG -SAFE. REQUEST FOR MARKINGS CAN BE MADE BY CALLING DIG -SAFE AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO EXCAVATION. STREET OPENING PERMITS SHOULD ALSO BE FILED AT THAT TIME. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHOWN ARE APPROXIMATE AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL FIELD VERIFY THE SIZE AND EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY THE CONTRACTOR'S FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. ALL EXISTING UTILITY SERVICE CONNECTIONS SHALL BE ABANDONED UNLESS NOTED OTHERWISE. THE WATER AND SEWER SERVICES SHALL BE CUT AND CAPPED AT THE MAIN IN THE STREET BY THE CONTRACTOR IN ACCORDANCE WITH THE CITY OF SALEM STANDARDS. THE PROPOSED GAS, ELECTRIC AND/OR CATV INSTALLATION AND ABANDONMENT OF EXISTING CONNECTIONS SHALL BE COORDINATED BY THE CONTRACTOR WITH THE RESPECTIVE COMPANIES. FINAL DEMARCATION POINTS FOR GAS, ELECTRIC, TELEPHONE, AND COMMUNICATION SERVICE ENTRANCES ARE SUBJECT TO APPROVALS OF EACH PROVIDER. ALL UTILITIES SHOWN ON THIS SITE ARE TO THE EXTERIOR OF THE BUILDING FOUNDATION ONLY. UTILITIES THROUGH THE FOUNDATION AND INSIDE THE BUILDING ARE THE RESPONSIBILITY OF THE MECHANICAL ENGINEER. SEE MECHANICAL ENGINEERING PLANS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND RECORDING THE EXACT LOCATION OF ALL PROPOSED UTILITY CONNECTIONS. NEW WATER SERVICES MUST BE LEFT SHUT OFF AT THE MAIN ON THE STREET UNTIL ACTIVATED BY CITY OF SALEM. A DYE TEST SHALL BE PERFORMED PRIOR TO THE ISSUANCE OF AN OCCUPANCY PERMIT. THE CONTRACTOR SHALL SUPPLY ALL PIPING FOR THE UTILITY SERVICES AND SHALL SUPPLY ALL ASSOCIATED APPURTENANCES, FITTING AND VALVES UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL PERFORM ALL WET AND DRY TAPS AS PART OF HIS/HER CONTRACT. ALL PLUMBING FIXTURES BELOW THE LEVEL OF THE RIM OF THE SEWER MANHOLE SERVICING THE FIXTURE(S) SHALL BE CONSIDERED AS BEING SUBJECT TO BACKFLOW AND SHALL BE SUPPLIED WITH BACKWATER VALVES. CITY OF SALEM RESERVES THE RIGHT TO INSPECT ALL FACILITIES DISCHARGING TO THE CITY OF SALEM DRAIN AND SEWER SYSTEMS. PRIOR TO CONSTRUCTION OF NEW SANITARY SEWER, STORM DRAIN LINES AND MANHOLES, CONTRACTOR TO PERFORM TEST PITS AT LOCATIONS OF EXISTING LATERAL CONNECTIONS FOR SANITARY SEWER AND STORM DRAINS TO CONFIRM INVERTS OF LATERALS. ANY DISCREPANCIES ARE TO BE REPORTED TO THE ENGINEER IMMEDIATELY. THE RESPONSIBILITY OF OWNERSHIP AND MAINTENANCE OF THE SEWER, WATER, AND DRAIN CONNECTIONS ON PRIVATE PROPERTY AND/OR PRIVATE AND PUBLIC WAYS SHALL REMAIN THAT OF THE OWNER. ONCE THE CONDOMINIUM ASSOCIATION IS IN PLACE, THE RESPONSIBILITY FOR MAINTENANCE SHALL BE THAT OF THE ASSOCIATION. WHERE AN EXISTING UTILITY IS FOUND TO CONFLICT WITH THE PROPOSED WORK, THE LOCATION, ELEVATION AND SIZE OF THE UTILITY SHALL BE ACCURATELY DETERMINED WITHOUT DELAY BY THE CONTRACTOR, AND THE INFORMATION SHALL FURNISH TO THE ENGINEER FOR RESOLUTION OF THE CONFLICT. TRENCH AREAS FOR THE CONSTRUCTION OF THE UNDERGROUND UTILITIES ARE TO BE REPATCHED WITH SAME MATERIAL AT THE SAME DEPTH AS THE EXISTING MATERIAL. THE AREAS OF TRENCHING SHALL BE NEATLY SAW -CUT AND THE NEW REPATCHING MATERIAL SHALL BE PROPERLY SEALED IN ACCORDANCE WITH THE TOWN OF NEEDHAM MUNICIPAL STANDARDS. DURING EXCAVATION AND CONSTRUCTION OF PIPES AND STRUCTURES, TRENCHES MUST BE ADEQUATELY BRACED AND PROTECTED AGAINST CAVE-IN. NO TRENCHES ARE ALLOWED TO REMAIN OPEN OVERNIGHT. ALL TRENCHES SHALL BE BACKFILLED AT THE END OF THE WORK DAY OR COVERED WITH STEEL PLATES PER 520 CMR 14.00 EXCAVATION AND TRENCH SAFETY. IF STEEL PLATES ARE USED, THE TOTAL LENGTH OF PLATES IN THE TRAVELED WAY SHALL LIMITED TO 50' PROVIDE NEW SLEEVE CROSSINGS AT WATER CONNECTIONS AT WASHINGTON STREET AS NECESSARY. 3( SN. -o- DH.SB. p FN D. D -S E -CA O wv GV 48, RIM = INV.IN/OUT= SWW ❑ CPE STC DMH CB GI LEGEND LIGHT POLE STREET SIGN FIRE HYDRANT DRILL HOLE IN STONE BOUND FOUND PUBLIC DRAIN SERVICE PUBLIC SEWER SERVICE PUBLIC WATER SERVICE UNDERGROUND TELECOMM. LINES UNDERGROUND ELECTRIC LINES UNDERGROUND CABLE TV & COMM. LINES DRAIN MANHOLE SEWER MANHOLE TELECOMM. MANHOLE ELECTRIC MANHOLE HANDICAP ACCESS / RAMP TREE WATER VALVE (GATE) GAS VALVE (GATE) WATER SHUT-OFF DIRECTION OF FLOW MANHOLE RIM ELEVATION IN OR OUT PIPE INVERT ELEVATION WATER METER / GATE CORRUGATED POLYETHYLENE STORMCEPTOR PARTICLE SEPARATOR DRAIN MANHOLE CATCH BASIN GUTTER INLET PROPOSED CURB PROPOSED CURB BY OTHERS /3,5 PIPE MATERIALS: DOMESTIC WATER SERVICE: 4 INCH DUCTILE IRON CEMENT LINED (DICL) CLASS 52 (TO BE CONFIRMED BY MEP) FIRE SERVICE: 6 INCH DUCTILE IRON CEMENT LINED (DICL) CLASS 52 (TO BE CONFIRMED BY MEP) ALL WATER LINES SHALL HAVE A MINIMUM OF FIVE (5) FEET OF COVER SANITARY SEWER: STORM DRAIN: ROOF DRAIN: O/ 4 SMH RELQZN ff PROP. 0? ,0 G4 EXI R• T AT RAL RAL NDONED 1012" CPE S=0.0177 a)0 STC =31.39 INV=28.34 8 INCH CAST IRON SERVICE TO BLDG MINIMUM SLOPE= 0.020 12 INCH (MIN.) CPE (UNLESS OTHERWISE NOTED) MINIMUM SLOPE= 0.010 6 INCH (MINIMUM) CAST IRON (UNLESS OTHERWISE NOTED) MINIMUM SLOPE= 0.020 MINIMUM COVER= 2 FT CB RIM=31.23 INV=28.23 DMH NO ELEV. DATA Q HI.R IN #257 4 STORY APT. BUILDING BY BRICK FACADE & CONC. FOUNDATION SMH-4 R-24.61 INV=2 •..4 MH I.RIM=27. .RIM=28. V.=20.25 CBCI R=28.92 1=24.9(R 1OLF 12" CPE S=0.017 36LF 12" S=0.017 83LF 12" CPE S=0.043 CB RIM=31.23 INV=28.23 R=24.20 P F \ AB N SE' VI L.POLE RVICE LK. FCE. S=0.021 SMH P R=22.27* 1=2.87 24" VAULT/ \ / DMH RIM=28.30 INV=25.00 SMH-2 R=23.51 SMH R=21.95* 1=2.70 TRAFF.LIGHTS TUPPORT POLE / / DMH- R=20.84* IN=16.94(CB) I.IN=14.44 I.OUT=14.34 AFF. CONTROL CABINET 4" DI DOMESTIC WATER SERVICE (SEE MEP PLANS FOR CONTINUATION) 6" DI FIRE PROTECTION WATER SERVICE (SEE MEP PLANS FOR CONTTTTTTTTTAT /ROOF DRAINAC. / INV=25.15 / N / (SEE MEP PKANIS' / FOR CONTINUA IN) ROOF ELEV.-47.1' 2 STORY BY BRICK FACADE EMTR ROOF ELEV. 36.8. 1 STORY CONC. BLOCK COMM. VAULT 6" (MIN) DI S=0.02 EOppNNECT TO EXIST STUB - RO90- DRAINAGE IN 17.60 (SEE MEP PLANS FOR CONTINUATION) 6" DI SEWER CONNECT TO EXIST STUB 8" DI S=0.020 (SEE MEP PLANS FOR CONTINUATION) 500 GAL. GREASE TRAP RIM=14.00 INV (IN)=8.33 (OUT)=8.08 500 GAL. OIL/WATER SEPERATOR RIM=14.00 INV =9.91 INV GOUT)= .91 _ 1 0 1 yI 0 1 L_ _ J L_ _ 42LF 8" DI 0.020 I 0 I L_ _ I 0 I L -J CB RIM=13.75 INV=10.75 I 0 1 PFIOPOINFIILTRATION Sf'STM 1 L - J B(ETO JOF STONE EIL10.3J (FINAL LOCATION AND CONFIGURATION TO BE COORDINATED WITH FOOTING _ E T E T PLAC�MEN-71 10 I 10 I 10 I L_ - J L_ _ J L_ - J PROP. GAS SERVICE AND METER LOCATION. - T-O�EONFIRMED 7 EIXISJINl HYDRANT - 0 I PROVID R 0 1 L-JTOREMAIN.L -J _I PROTECT PROTECT DURING CONSTRUCTION SMH R=20.00 Ln" 1(a)=16.01 I a I(b)=16.08 I(c)=15.90 HH 21.08 EMH #8-213 E - OE x 17.0 4 L.POLE #0 ,. GAS PL LP 2004 x 16.2 i \TRPED DMH R=14.88 1.1=10.73(CB) I.IN=4.03 I.OUT=4.00 CUT & CAP CB SMH EXIST. SERi/iES R=15.82 F AT MAIN„low. ii�t apy • :roliwg � _gip- LlikAilii.k I ROOF DRAINAGE INV=10 (SEcEG EP PLANS FOR CONTINUATION) (SEE MEP r • • CON IUA ION) SMH 5/8" VALVE FOR FLOPD WATER /'ONTROL 10"DI ��� 10 8" CAST IRON WATER LINEW 4 WATER LINE lD4 W LP BASE 8" DI S=0.020 6" DI S=0.020 PROP. DMH RIM=14.0± INV. IN=9.86 INV.OUT=9.81 W W S 6"PVC 4" GASGCI LP 1913 SMH R=14.0 1=9.91 SMH R 14.12 I.IN 2.25 7I.0U 2.20 DODGE ST. BAR & GRILL L.POL W/RI SWWG ci ter ...� R=1 .88c8B 1 9.0 es, - _ _ DMH R=15.00* I.IN=4.00 LOUT=3.98 SOUTH RIVER CONDUIT TWIN 72" DIA. PIPES OJI EMH #C-21 w -57 EMH 8"PL HP CB R=13. 1=10.1 WATER METER F WATER METER \ \ ELEC.` R=13.28 1=11.03 MH R=13.65 20"CI WATER 2"PL vs. ENG #193 - 211 WASHINGTON ST. 9 (DI ❑ ❑ IC\ p I CV MH HI.RIM=14.79' GG J 0 STARBUCKS COFFEE ROOF ELEV. = 47.4' BRICK FACADE / STONE FOUNDATION DMH R=13.32 I(a)=5.13 I(b)=5.13 1(e)=6.72 I(d)=7.10 I(e)=9.52 GAS METER NS DMH R=13.71 I(a)=5.66 I(b)=5.50 1(c)=7.61 I(d)=7.76 I(e)=9.76 LOCATE DRANT TELECOM. VERIZON #171 SMH R=14.08' 8"VC `I0 .0 0 0 DMH R=13.71 I(o)=6.2 I(b)=5.8 2"PL G- 14.11 S DMH R=14.37 I(a)=9.0 1(b)=6.2 1(c)=8.3 1(d)=7.7 I(e)=6.3 W8"CI WATER CB R=13.61 1=8.9 20 40 FEET E9z NORTH DCI Design Consultants Inc. Somerville - Quincy - Newburyport www.dci-ma.com APPLICANT: DODGE AREA, LLC c/o OPECHEE CONSTRUCTION CORP. BELMONT, NH 03220 603-527-9090 9-11 Dodge St., 217-219 & 231-251 Washington St., Salem, MA PROJECT INFO REVIEW COMMENTS 5/9/18 REV DESCRIPTION DATE PROPOSED UTILITIES PLAN SHEET NAME: C400 SHT NO: DR BY: DM CHK BY: ES PROJ NO: 2018-005 DATE: 03.14.2018 SCALE: 1 "=20'