JOLIE TEA - CALCS Project Name : TENANT FIT-UP - JOLIE TEA COMPANY Drawing No. : 290-172 Project Location: 316 DERBY STREET City: SALEM, MA 01970CALCULATION SUMMARYDesign AreasDesign AreaNameMin.DensityArea ofApplicationOccupancyCalculatedHeadsMin.PressureHoseStreamsTotal WaterPressure @SourceMargin ToSource(gpm/ft²)(ft²)#(psi)(gpm)(gpm)(psi)(psi)Min.Flow(gpm)Calc. Mode(Model) 1ORD HAZ I1500294.4Required39.90.1519.514022.112.1Demand (HW)Date 4/1/2020Page 1Copyright © 2002-2012 Tyco Fire Protection ProductsFile: JOLIE TEA - FP.dwg04-01-2020 Design Remote Area Name Remote Area Location Occupancy Classification Density (gpm/ft²) Area of Application (ft²) Coverage per Sprinkler (ft²) Number of Calculated Sprinklers In-Rack Demand (gpm) Special Heads Hose Streams (gpm) Total Water Required (incl. Hose Streams) (gpm) Required Pressure at Source (psi) Type of System Volume - Entire System (gal) 1 JOLIE TEA ORD HAZ I 0.15 1500 130 14 0 0 294.4 39.9 Wet 189.6 gal Water Supply Information Date Location Source HYDRAULIC CALCULATIONS for SYSTEM RISER W1 THIS CALCULATION INCLUDES THE HMD 1500 SF OF RENOVATED TENANT SPACE Project Name : TENANT FIT-UP - JOLIE TEA COMPANY Contract No. : 290-172 Project Location: 316 DERBY STREET City: SALEM, MA 01970 Date: 4/1/2020 Name of Contractor: D.A.S. FIRE PROTECTION Address: 62 FOREST RIDGE DRIVE Phone Number: (978) 360-8459 Name of Designer: JFP SOLUTIONS, INC. Authority Having Jurisdiction: SALEM FD City: ROWLEY, MA 01969 E-mail: Job Information Contractor Information Notes Date 4/1/2020 Page 2Copyright © 2002-2012 Tyco Fire Protection Products File: JOLIE TEA - FP.dwg Job : TENANT FIT-UP - JOLIE TEA COMPANYDiagram for Design Area : 1 (Optimized Hydraulic Simplified)Node Labels:Pipe Labels:OffOffDate 4/1/2020Page 3Copyright © 2002-2012 Tyco Fire Protection ProductsFile: JOLIE TEA - FP.dwg Job : TENANT FIT-UP - JOLIE TEA COMPANY Hydraulic Analysis for : 1 Water Supply Parameters Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft³) Fluid Dynamic Viscosity, (lb·s/ft²) Demand Hazen-Williams Water @ 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Supply 1 : W1 Flow (gpm)Pressure (psi) 0 65 700 50 Node at Source Static Pressure (psi) Residual Pressure (psi) Flow (gpm) Available Pressure (psi) Total Demand (gpm) Required Pressure (psi) Supply Analysis W1 65 50 700 62 294.4 39.9 Inside Hose Flow / Standpipe Demand (gpm) Outside Hose Flow (gpm) Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) Total Hose Flow (gpm) Hoses Ovehead Sprinkler Flow (gpm) InRack Sprinkler Flow (gpm) Other (custom defined) Sprinkler Flow (gpm) Total Sprinkler Flow (gpm) 294.4 0 0 294.4 Required Margin of Safety (psi) W1 - Pressure (psi) W1 - Flow (gpm) Demand w/o System Pump(s) 0 39.9 294.4 N/A Sprinklers Other Date 4/1/2020 Page 4Copyright © 2002-2012 Tyco Fire Protection Products File: JOLIE TEA - FP.dwg Job : TENANT FIT-UP - JOLIE TEA COMPANYHydraulic Analysis for : 1Flow, gpmPressure, psi706050403020100S1S245.797D1D2SupplySystem Demand0300 400500600700800Date 4/1/2020Page 5Copyright © 2002-2012 Tyco Fire Protection ProductsFile: JOLIE TEA - FP.dwg Job : TENANT FIT-UP - JOLIE TEA COMPANY Hydraulic Analysis for : 1 Pressure (psi)Label Graph Labels Flow (gpm) ValuesDescription 0S1 65Supply point #1 - Static 700S2 50Supply point #2 - Residual 0D1 3.7Elevation Pressure 294.4D2 39.9System Demand Pressure (psi)Curve Name Curve Intersections & Safety Margins Flow (gpm) Safety MarginIntersection Pressure (psi)@ Flow (gpm) 374.8Supply60.3 22.1 294.4 Open Heads Head Ref. DensityDensity K-Factor PressureFlowPressure (gpm/ft²)(gpm/ft²)(gpm/psi½)(psi)(gpm)(psi) Flow (gpm) Coverage (ft²) Required Calculated Head Type S1 5.6 0.15 19.5 12.1 0.166 14.921.6130Overhead Sprinkler S10 5.6 0.15 19.5 12.1 0.154 12.720130Overhead Sprinkler S11 5.6 0.15 19.5 12.1 0.159 13.720.7130Overhead Sprinkler S12 5.6 0.15 19.5 12.1 0.162 14.221.1130Overhead Sprinkler S13 5.6 0.15 19.5 12.1 0.166 14.821.5130Overhead Sprinkler S14 5.6 0.15 19.5 12.1 0.161 1421130Overhead Sprinkler S2 5.6 0.15 19.5 12.1 0.168 15.221.8130Overhead Sprinkler S3 5.6 0.15 19.5 12.1 0.173 16.122.5130Overhead Sprinkler S4 5.6 0.15 19.5 12.1 0.172 15.922.3130Overhead Sprinkler S5 5.6 0.15 19.5 12.1 0.16 13.820.8130Overhead Sprinkler S6 5.6 0.15 19.5 12.1 0.157 13.320.4130Overhead Sprinkler S7 5.6 0.15 19.5 12.1 0.166 14.921.6130Overhead Sprinkler S8 5.6 0.15 19.5 12.1 0.15 12.119.5130Overhead Sprinkler Date 4/1/2020 Page 6Copyright © 2002-2012 Tyco Fire Protection Products File: JOLIE TEA - FP.dwg S9 5.6 0.15 19.5 12.1 0.151 12.319.6130Overhead Sprinkler Date 4/1/2020 Page 7Copyright © 2002-2012 Tyco Fire Protection Products File: JOLIE TEA - FP.dwg Job : TENANT FIT-UP - JOLIE TEA COMPANY Node Data Hydraulic Calculations / Fluid Delivery Time Analysis Node# Type Hgroup Fitting K-Fact. Stat. Pres. gpm/psi½ psi Elev Coverage ft ft² X Y ft ft S8 Overhead Sprinkler HEAD 5.6 0 13.5 130 2859.79 976.84 S9 Overhead Sprinkler HEAD 5.6 0 13.5 130 2859.79 986.84 S10 Overhead Sprinkler HEAD 5.6 0 13.5 130 2859.79 996.84 S6 Overhead Sprinkler HEAD 5.6 0 13.5 130 2873.79 986.84 S11 Overhead Sprinkler HEAD 5.6 0 13.5 130 2859.79 1006.84 S5 Overhead Sprinkler HEAD 5.6 0 13.5 130 2873.79 996.84 S14 Overhead Sprinkler HEAD 5.6 0 13.5 130 2847.29 976.84 S12 Overhead Sprinkler HEAD 5.6 0 13.5 130 2847.29 986.84 S13 Overhead Sprinkler HEAD 5.6 0 13.5 130 2847.29 998.34 S1 Overhead Sprinkler HEAD 5.6 0 13.5 130 2890.13 981.2 S7 Overhead Sprinkler HEAD 5.6 0 0 130 2877.46 977.83 S2 Overhead Sprinkler HEAD 5.6 0 13.5 130 2890.13 1001.2 S4 Overhead Sprinkler HEAD 5.6 0 13.5 130 2884.07 993.7 S3 Overhead Sprinkler HEAD 5.6 0 13.5 130 2884.07 1006.84 40 Overhead Sprinkler HEAD us.Tee 5.6 0 13.5 156 2873.79 976.84 61 Node NODE us.Tee 0 13.5 2888.13 1022.03 49 Node NODE us.Tee 0 13.5 2884.07 1022.03 32 Node NODE us.Tee 0 13.5 2873.79 1022.03 14 Node NODE us.Tee 0 13.5 2859.79 1022.03 08 Node NODE us.Tee 0 13.5 2847.29 1022.03 09 Node NODE us.90 0 13.5 2661.1 1022.03 W1 Supply SUPPLY 0 5 2626.7 1046.69 Date 4/1/2020 Page 8Copyright © 2002-2012 Tyco Fire Protection Products File: JOLIE TEA - FP.dwg Hydraulic CalculationsJob : TENANT FIT-UP - JOLIE TEA COMPANY PIPE INFORMATION Node 1 Node 2 Elev 1 Elev 2 (ft) K-Factor 1 K-Factor 2 (gpm/psi½) Flow added (q) Total flow (Q) (gpm) Nominal ID Actual ID (in) Fittings quantity x (name) = length (ft) L F T (ft) C Factor Pf per ft (psi) total (Pt) elev (Pe) frict (Pf) (psi) NOTES 1Path No: S8 S9 13.5 13.5 5.6 5.6 19.5 19.5 1.5 1.68 10 0 10 120 0.0125 12.1 0 0.1 S9 S10 13.5 13.5 5.6 5.6 19.6 39.1 1.5 1.68 10 0 10 120 0.0453 12.3 0 0.5 S10 S11 13.5 13.5 5.6 5.6 20 59.1 1.5 1.68 10 0 10 120 0.0972 12.7 0 1 S11 14 13.5 13.5 5.6 20.7 79.8 1.5 1.68 1x(us.Tee-Br)=9.84 15.19 9.84 25.04 120 0.1696 13.7 0 4.2 14 08 13.5 13.5 151 230.8 3 3.26 12.5 0 12.5 120 0.0481 17.9 0 0.6 08 09 13.5 13.5 63.6 294.4 3 3.26 1x(us.90)=9.41 186.19 9.41 195.59 120 0.0754 18.5 0 14.8 09 W1 13.5 5 0 294.4 4 4.26 4x(us.90)=52.67 89.92 52.67 142.59 120 0.0205 33.3 3.7 2.9 W1 39.9 2Path No: S6 S5 13.5 13.5 5.6 5.6 20.4 42 1.5 1.68 10 0 10 120 0.0518 13.3 0 0.5 S5 32 13.5 13.5 5.6 20.8 62.8 1.5 1.68 1x(us.Tee-Br)=9.84 25.19 9.84 35.04 120 0.109 13.8 0 3.8 32 14 13.5 13.5 88.2 151 3 3.26 14 0 14 120 0.0219 17.6 0 0.3 14 17.9 3Path No: S14 S12 13.5 13.5 5.6 5.6 21 21 1.5 1.68 10 0 10 120 0.0143 14 0 0.1 S12 S13 13.5 13.5 5.6 5.6 21.1 42.1 1.5 1.68 11.5 0 11.5 120 0.0519 14.2 0 0.6 S13 08 13.5 13.5 5.6 21.5 63.6 1.5 1.68 1x(us.Tee-Br)=9.84 23.69 9.84 33.54 120 0.1115 14.8 0 3.7 08 18.5 Date 4/1/2020 Page 9Copyright © 2002-2012 Tyco Fire Protection Products File: JOLIE TEA - FP.dwg Hydraulic CalculationsJob : TENANT FIT-UP - JOLIE TEA COMPANY PIPE INFORMATION 4Path No: S1 S2 13.5 13.5 5.6 5.6 21.6 21.6 1.5 1.68 20 0 20 120 0.0151 14.9 0 0.3 S2 61 13.5 13.5 5.6 21.8 43.4 1.5 1.68 1x(us.Tee-Br)=9.84 2x(us.90)=9.84 22.83 19.68 42.51 120 0.055 15.2 0 2.3 61 49 13.5 13.5 0 43.4 3 3.26 4.06 0 4.06 120 0.0022 17.5 0 0 49 32 13.5 13.5 44.8 88.2 3 3.26 10.28 0 10.28 120 0.0081 17.5 0 0.1 32 17.6 5Path No: S7 40 0 13.5 5.6 21.6 21.6 1 1.049 1x(us.Tee-Br)=5 2x(us.90)=4 18.16 9 27.16 120 0.1498 14.9 -5.8 4.1 40 S6 13.5 13.5 5.6 0 21.6 1.5 1.68 10 0 10 120 0.0151 13.1 0 0.2 S6 13.3 6Path No: S4 S3 13.5 13.5 5.6 5.6 22.3 22.3 1.5 1.68 13.14 0 13.14 120 0.016 15.9 0 0.2 S3 49 13.5 13.5 5.6 22.5 44.8 1.5 1.68 1x(us.Tee-Br)=9.84 15.19 9.84 25.04 120 0.0582 16.1 0 1.5 49 17.5 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 11.55 ft/s occurs in the following pipe(s): (14-S11) Date 4/1/2020 Page 10Copyright © 2002-2012 Tyco Fire Protection Products File: JOLIE TEA - FP.dwg Device GraphsJob : TENANT FIT-UP - JOLIE TEA COMPANY Pressure vs. Flow Function Design Area: 1; Supply Ref.: W1; Supply Name:W1 Flow, gpm0100200300400500 600700Pressure, psi70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 Date 4/1/2020 Page 11Copyright © 2002-2012 Tyco Fire Protection Products File: JOLIE TEA - FP.dwg