FW Webb Salem Stamped FD Fire Alarm Drawings 6.10.19
EXISTING KNOX BOX TO REMAIN EXISTING EXTERIOR BEACON TO REMAIN NEW RADIO NEW RADIO DIALER TO FIRE DEPARTMENT BOILER (oo7) WATER 7 SERVICE TELE EXIST. STAIR PIPES UP '1ST STAIR PIPES OLD ELEVATOR SHAFT WITH INFIL ED FLOOR (0 I) EL FLED PANELS CTRIC/SPRINKLER (008) SPRINKLER BUILDING A NEW STAIR PIT (006) BASEMENT 110 Lf1-13-ff_ 0 1 0 1 o 0--8 11 5th Fl -if 8 11— 0 1 0 1 © ff-6jo 11 4th FII ss -if UIf— 0 f 0 f 14 If-4U If 3rd Fli 4 S 0_- 0 1 0 1 0 0--f 11 2nd Ft -ff- 8 f1— 0 1 0 1 0 IF- o6 0 1st Fir -8 1 � u, LTSJ L*J [is; Lam, I Di IA-1 6 o 1 o 1 o f - 1 ® ® © ® ® ® ® ® f- v ` . Bsmt %"...„1/40 r EXISTING FLOWS & TAMPERS NEW FLOW & FOR BACKFLOW ON EXISTING DRY VALVES TAMPER FOR PREVENTER 3-1 WET SYSTEM TELEPHONE UNE CONNECTED TO NEW ADDRESSABLE ARE ALARM K&J SECURITY FOR OWNER MONITORING (DATA CABLE) CONTROL PANEL TO REMAIN RP1 A-7 ---I BATT FIRE ALARM RISER DIAGRAM N.T.S. r BUILDING B BASEMENT (002) 110 FREIGHT ELEVATOR PIT (003) BUILDING C BASEMENT 110 SPEAKER/STROBE INDICATION APPLIANCE ROOF TOP UNIT REMOTE TEST SWITCH TOP OF GONDOLA COLUMN Om 72" FLOOR 80" HORN/STROBE N.T.S.RTS MOUNTING DETAIL NOTES: 1. MOUNT DEVICES AS HIGH AS POSSIBLE SO AS TO NOT ALLOW THE PRODUCT ON THE RACKING UNITS TO INTERFERE WITH THE LIGHT. ASSUME MOUNTING DEVICES IN 4" SQUARE BOX DIRECTLY TO BOTTOM OF STEEL BEAMS. PROVIDE STEM MOUNTING IF REQUIRED BY STRUCTURE IN WHICH DEVICE SHALL BE AT THE STURCTURAL STEEL ELEVATION. 2. DUCT MOUNTED SMOKE DETECTORS FOR ROOF TOP UNITS ARE PROVIDED UNDER THIS CONTRACT. PROVIDE REMOTE MOUNTED TEST SWITCHES FOR ALL DUCT SMOKE DETECTORS. DETECTORS USED TO SENSE SMOKE FROM THE HVAC UNITS SHALL BE CONNECTED TO irs UNITS CONTROL POINT FOR SHUTDOWN OF THE UNIT UPON SENSING SMOKE. DETECTOR SHALL TRANSMIT A TROUBLE SIGNAL TO THE FIRE ALARM CONTROL PANEL IF IT 1S ACTIVATED. 3. FIRE ALARM RISER IS DIAGRAMATICAL AND IS NOT INTENDED TO SHOW EVERY DEVICE. QUANTITY OF DEVICES PER LOOP SHALL BE DETERMINED BY REVIEWING THE FLOOR PLANS AS WELL AS THE ACTUAL FIELD CONDITIONS. 4. SYSTEM MANUFACTURER SHALL PROVIDE FULL AND COMPLETE SHOP DRAWINGS INCLUDING ALL BATTERY CALCULATIONS, SIZING OF SLC CIRCUITS AND CALCULATIONS FOR MAXIMUM QUANTITY OF DEVICES ON EACH LOOP, AND COMPLETE RISER DIAGRAM. SHOP DRAWINGS SHALL ALSO CONTAIN ALL INFORMATION RELATED TO THE DEVICES WITHIN THE SYSTEM BEING SUBMITTED ON. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR A COMPLETE TEST OF THE ENTIRE FIRE ALARM SYSTEM, IN CONJUNCTION WITH THE MANUFACTURER PRIOR TO THE FIRE DEPARTMENT ACCEPTANCE TESTING. ALL DEFICIENCIES FOUND DURING THIS TEST SHALL BE CORRECTED PRIOR TO THE FIRE DEPARTMENT TESTING. 6. ALL FIRE ALARM SYSTEM WIRING SHALL BE COPPER AND SHALL BE UL USTED FOR IT'S USE. 7. THERE SHALL BE NO "T" TAPPING ALLOWED ON ANY FIRE ALARM CIRCUIT. 8. ALL A/V UNITS SHALL BE SYNCHRONIZED. 9. PROVIDE A MINIMUM OF 20% SPARE CAPACITY ON ALL NOTIFICATION APPLIANCE CIRCUITS 10. ALL WORK SHALL BE COORDINATED WITH THE LOCAL FIRE DEPARTMENT. 11. FIRE ALARM SYSTEM SHALL BE ADDRESSABLE CLASS "A" WIRED. ALL DEVICES SHALL BE ADDRESSABLE. 12. ALL WORK SHALL BE COORDINATED WITH THE LOCAL FIRE DEPARTMENT. 13. A NEW CLASS "A" WIRED FULLY ADDRESSABLE FIRE ALARM SYSTEM SHALL BE PROVIDED. NEW PANEL SHALL CONNECT TO THE LOCAL FIRE DEPARTMENT VIA TELEPHONE TO K&J INTEGRATED SYSTEMS (THE OWNERS CENTRAL STATION). COORDINATE WITH THE GC TO OBTAIN ALL INFORMATION FOR K&J INTEGRATED SYSTEMS. 14. ALL FIRE ALARM.CABUNG SHALL BE TYPE FPLP OR FPL AND SHALL BE RUN AS MC CABLE OPEN SUPPORTED BY THE STRUCTURE. 15. ALL DEVICES LOCATED ON THE 2ND FLOOR BUILDING B & C AS WELL AS ALL DEVICES LOCATED ON THE 3RD, 4TH AND 5TH FLOORS SHALL BE COLD WEATHER RATED AS THERE IS NO HEAT IN THOSE SPACES. F.W. WEBB COMPANY 295 BRIDGE STREET SALEM, MA .DEAF 8 Aarams.Street, Suite-: 05 Leominster,: MA 01 453 ✓. reehLeafCM.co IsoEigncadence Architecture Space Planning Interior Design Site Planning Project Management 200 Baker Avenue Concord, MA 01742 978 369 6565 DesignSciencelnc.com Architect Design -Science International, Inc. 200 Baker Avenue Concord, MA 01742 Andy Loverud 978 369-6565 Andy@DesignSciencelnc.com Consultant S.B. SAGER & ASSOCIATES CONSULTING ENGINEERS ELECTRICAL SYSTEMS SPECIALISTS 2 CANTON STREET - SUITE B-229 STOUGHTON, MA 02072 (TEL) 781-341-4770 (FAX) 781-341-6020 O O A-tPPtinlIS D Su":ja{t to approval by any oche authority .having Juridictiott. CITY of SALEM, MASS. PRE R N • N BUREAU a n.. 4 yi PLAN? ARC APPROVED SOLELY FOR IDEtkT1-'FICATION OFF. TYPE AND LOCATION OF NW MOT,E1X1DN DEVICES. ALL PIP,P, PROTECTION DEVICES ...n.0 OuasEC'i TO ,R, =IN:.. TEST AND INSPECTION, FOR COMPLETECOMPUt 4 Revisions 2 [ 5/3/19 Construction Set 1 3/25/19 Meeting with Owner No. Date . Description Sheet Title BASEMENT NEW FIRE ALARM PLAN 16 PROVIDE CONTROL MODULES AS REQUIRED FOR THE CONVENTIONAL DEVICES INDICATED IN NOTE #15 ON ALL COLD FLOORS. WE BELIEVE THERE IS A TOTAL OF 8 REQUIRED. 18 Orientation -Scale -Date 4-2-2019 4 0 feet 8 16 Sheet Number Number FA-1 a C EXIST CTAIR ELECTRIC OMEN SECOND FLOOR PLAN SCALE: 1 /8" =11 0" IC RANI' IRAX. CIl1Pt: I; I', Sh10W. M{ I I RE ALAR<N CONTROL PANEL 2� RST FLOOR PLAN 1' 0" BUILDING A HVAO (207) \ JANITOR (206) BUILDING A G1,11 SI RVI (IOI) KILEN OFFICE (201G OFFICE SUPPLIE O OFFICE 6202) RECEPTION (200) HALL 210 15 pc/etc LO KED ST RAGF CONFERENCE d Delete SELF SERVE NEW STAIR NEW STAIR WOMEN (105) JANITOR (106) BUILDING B 1 BUILDING B SENCNC 0 FREIGHT ELEVATOR (216) WAREHOUSE MANAGERS (off SHIPPING RE4�EIVIN BUILDING C 110 BUILDING C W A-REHOUtE f SHLLVINJ 11 — —I F.W. WEBB COMPANY 295 BRIDGE STREET SALEM, MA !II GREEN LEAF CONSTRUCTION 98 Adams Street, Suite 105 Leominster, MA 01453 www.GreenLeafCM.com DoWani=iScriscace Architecture Space Planning Interior Design Site Planning Project Management 200 Baker Avenue Concord, MA 01742 978 369 6565 DesignSciencelnc,com Architect Design -Science International, Inc. 200 Baker Avenue Concord, MA 01742 Andy Loverud 978 369.6565 Andy@DesignSciencelnc.com Consultant S.B. SAGER 8t ASSOCIATES CONSULTING ENGINEERS ELECTRICAL SYSTEMS SPECIALISTS 2 CANTON STREET - SUITE B-229 STOUGHTON, MA 02072 (TEL) 781-341-4770 (FAX, 781-341-6020 r l Revisions 1 [ 2 5/3/19 Construction Set No. Date Description J Sheet Title 1st & 2nd FLOOR FIRE ALARM PLANS Orientation - Scale - Date 4-2-2019 4 0 feet FA-1 bl m� Sheet Number BUILDING A BUILDING B BUILDING C Project: 18103 F.W. WEBB COMPANY 295 BRIDGE STREET SALEM, MA BULK STORAGE (400) 405 3 F319' STAIR DN OLD ELEVATOR HAFT VP �H INOlL ED FLOOR RTH FLOOR PLAN II If BULK STORAGE 00 3 BULK STORAGE (402) BULK STORAGE (402) ll Jf BUILDING B NEW STAIR 306 FREIGHT ELEVATOR (403) 1 FREIGHT ELEVATOR (303) 713� BULK STORAGE (404) BULK STORAGE (404) BUILDING C 15� JC 1 ❑ B iB S-11 2,A ,F (304) Lv. cT0 (33.4 PC€ �4� GREEN LEAF CONSTRUCTION 98 Adams Street, SuitP 105 I P niincter, MA 01453 www.GreenLeafCM.com Deafignarlence Architecture Space Planning Interior Design Site Planning Project Management 200 Baker Avenue Concord, MA 01742 978 369 6565 DesignSciencelnc.com Architect DesignSciance International, Pnc. 200 Baker Avenue Concord, MA 01742 Andy Loverud 978 369-6565 Andy@DesignSciencelnc.com Consultant S.B. SAGER & ASSOCIATES CONSULTING ENGINEERS ELECTRICAL SYSTEMS SPECIALISTS 2 CANTON STREET - SUITE 8-229 STOUGHTON, MA 02072 (TEL) 781-341-4770 (FAX) 781-341-6020 )O i Revisions 2 5/3/19 Construction Set No. Date Description Sheet Title 3rd & 4th FLOORS FIRE ALARM PLANS Orientation - Scale - Date 4-2-2019 N e s 4 0 feet 8 16 BUILDING A OLD ELEVATOR SHAFT '' TH INFILED FL00R C BULK STORAGE (500 11 BULK STORAGE (500) o IC BUILDING B 0 BULK STORAGE (502) BULK STORAGE (502) FREIGHT ELEVATOR (503) BUILDING C BULK STORAGE (504) ❑ _. BULK STORAGE (504) Project: 18103 F.W. WEBB COMPANY 295 BRIDGE STREET SALEM, MA Leominste r,MA01 45 3 w.GreenLeafCM .corn lemignoSchence Architecture Space Planning Interior Design Site Planning Project Management 200 Baker Avenue Concord, MA 01742 978 369 6565 DesignSciencelnc.com Architect Design -Science International, Inc. 200 Baker Avenue Concord, MA 01742 Andy Loverud 978 369-6565 Andy@DesignSciencelnc.com Consultant S.B. SAGER & ASSOCIATES CONSULTING ENGINEERS ELECTRICAL SYSTEMS SPECIALISTS 2 CANTON STREET - SUITE B-229 STOUGHTON, MA 02072 (TEL) 781-341-4770 (FAX) 781-341-6020 [Revisions 2 5/3/19 Construction Set No. Date Description Sheet Title 5th FLOOR FIRE ALARM PLAN 1 Orientation - Scale - Date E 4-2-2019 N©S 8 4 0 feet 8 16 Sheet Number FA-1d