Loading...
07 Wheatland PipeProject: engineer: Locations: contractor: sPecification reference: Date: system tyPe: comments: Submittal information fm approved and fully listed Sprinkler Pipe Wheatland’s Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. approvals and Specifications Both products meet or exceed the following standards: • ASTM A135, Type E, Grade A (Schedule 10) • ASTM A795, Type E, Grade A (Schedule 40) • NFPA 13 manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM / UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. Wheatland tube 700 South Dock Street Sharon, PA 16146 P 800.257.8182 | f 724.346.7260 | info@wheatland.com | wheatland.com fire Sprinkler Pipe   Schedule 10 and Schedule 40 Submittal Data Sheet BLacK Hot-DiP gaLVaniZeD nPS nom oD nom iD nominal Wall nominal Weight ul PieCeS in.mm in.mm in.mm lbs. / ft.kg / m Crr*lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 1 ¼1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1 ½1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCheDule 40 SPeCifiCationS nPS nom oD nom iD nominal Wall nominal Weight ul PieCeS in.mm in.mm in.mm lbs. / ft.kg / m Crr*lift 1 ¼1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1 ½1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 2 ½2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCheDule 10 SPeCifiCationS fm approved and fully listed Sprinkler Pipe Wheatland’s A53 Schedule 40 steel fire sprinkler pipe is UL Listed and FM Approved, sizes 1 through 6 NPS, for use in fire sprinkler pipe applications, and is suitable for welding, threading and grooving. approvals and Specifications The product meets or exceeds the following standards: • ASTM A53, Type F, Grade A / 53M 1"–4" • ASTM A53, Grade A, 2"–6" • ASTM A53, Grade B, 2"–6" • ASME B36.10M • Federal Specification WW-P-404 manufacturing Protocols The weld seam of Wheatland’s A53 Schedule 40 is heat- treated after welding to 1400°F and is subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. finishes and Coatings The average weight of zinc coating shall not be less than 1.8 ounces per square foot of surface (inside and outside). When galvanized pipe is bent or otherwise fabricated to a degree that causes zinc coating to stretch or compress beyond the limit of elasticity, some flaking of the coating may occur. Product marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. nPS nom oD inCheS nominal Wall Wt. / ft. h2o filleD Wt. / lbS. ft. 2 2.375 .154 5.109 3.66 2 1/2 2.875 .203 7.871 5.80 3 3.500 .216 10.783 7.58 4 4.500 .237 16.311 10.88 5 5.563 .258 23.262 14.63 6 6.625 .280 31.498 18.99 8 8.625 .322 —28.58 WeightS anD DimenSionS Chart fire Sprinkler Pipe   A53 Schedule 40 Submittal Data Sheet Project: engineer: Locations: contractor: sPecification reference: Date: system tyPe: comments: Submittal information Wheatland tube 700 South Dock Street Sharon, PA 16146 P 800.257.8182 | f 724.346.7260 | info@wheatland.com | wheatland.com