07 Wheatland PipeProject:
engineer:
Locations:
contractor:
sPecification reference:
Date:
system tyPe:
comments:
Submittal information
fm approved and fully listed Sprinkler Pipe
Wheatland’s Schedule 10 and Schedule 40
steel fire sprinkler pipe is FM Approved and UL,
C-UL and FM Listed.
approvals and Specifications
Both products meet or exceed
the following standards:
• ASTM A135, Type E, Grade A (Schedule 10)
• ASTM A795, Type E, Grade A (Schedule 40)
• NFPA 13
manufacturing Protocols
Schedule 10 and Schedule 40 are subjected
to the toughest possible testing protocols to
ensure the highest quality and long-lasting
performance.
finishes and Coatings
All Wheatland black steel fire sprinkler pipe
up to 6" receives a proprietary mill coating to
ensure a clean, corrosion-resistant surface that
outperforms and outlasts standard lacquer
coatings. This coating allows the pipe to be
easily painted, without special preparation.
Schedule 10 and Schedule 40 can be ordered in
black, or with hot-dip galvanizing, to meet
FM / UL requirements for dry systems that meet
the zinc coating specifications of ASTM A795
or A53. All Wheatland galvanized material is
also UL Listed.
Product marking
Each length of Wheatland fire sprinkler
pipe is continuously stenciled to show
the manufacturer, type of pipe, grade, size
and length. Barcoding is acceptable as a
supplementary identification method.
Wheatland tube 700 South Dock Street Sharon, PA 16146
P 800.257.8182 | f 724.346.7260 | info@wheatland.com | wheatland.com
fire Sprinkler Pipe
Schedule 10 and Schedule 40
Submittal Data Sheet
BLacK Hot-DiP gaLVaniZeD
nPS nom oD nom iD
nominal
Wall
nominal
Weight ul PieCeS
in.mm in.mm in.mm lbs. / ft.kg / m Crr*lift
1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70
1 ¼1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51
1 ½1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44
2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30
* Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY.
* The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion.
Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0).
SCheDule 40 SPeCifiCationS
nPS nom oD nom iD
nominal
Wall
nominal
Weight ul PieCeS
in.mm in.mm in.mm lbs. / ft.kg / m Crr*lift
1 ¼1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61
1 ½1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61
2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37
2 ½2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30
3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19
4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19
5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13
6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10
8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7
* Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY.
* The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion.
Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0).
SCheDule 10 SPeCifiCationS
fm approved and fully listed Sprinkler Pipe
Wheatland’s A53 Schedule 40 steel fire sprinkler pipe is UL
Listed and FM Approved, sizes 1 through 6 NPS, for use
in fire sprinkler pipe applications, and is suitable for welding,
threading and grooving.
approvals and Specifications
The product meets or exceeds the following standards:
• ASTM A53, Type F, Grade A / 53M 1"–4"
• ASTM A53, Grade A, 2"–6"
• ASTM A53, Grade B, 2"–6"
• ASME B36.10M
• Federal Specification WW-P-404
manufacturing Protocols
The weld seam of Wheatland’s A53 Schedule 40 is heat-
treated after welding to 1400°F and is subjected to the
toughest possible testing protocols to ensure the highest
quality and long-lasting performance.
finishes and Coatings
The average weight of zinc coating shall not be less than 1.8
ounces per square foot of surface (inside and outside). When
galvanized pipe is bent or otherwise fabricated to a degree that
causes zinc coating to stretch or compress beyond the limit of
elasticity, some flaking of the coating may occur.
Product marking
Each length of Wheatland fire sprinkler pipe is continuously
stenciled to show the manufacturer, type of pipe, grade, size
and length. Barcoding is acceptable as a supplementary
identification method.
nPS nom oD
inCheS
nominal
Wall
Wt. / ft.
h2o filleD
Wt. / lbS.
ft.
2 2.375 .154 5.109 3.66
2 1/2 2.875 .203 7.871 5.80
3 3.500 .216 10.783 7.58
4 4.500 .237 16.311 10.88
5 5.563 .258 23.262 14.63
6 6.625 .280 31.498 18.99
8 8.625 .322 —28.58
WeightS anD DimenSionS Chart
fire Sprinkler Pipe
A53 Schedule 40
Submittal Data Sheet
Project:
engineer:
Locations:
contractor:
sPecification reference:
Date:
system tyPe:
comments:
Submittal information
Wheatland tube 700 South Dock Street Sharon, PA 16146
P 800.257.8182 | f 724.346.7260 | info@wheatland.com | wheatland.com