107 Bridge St Specs
PDA Electrical Inc 111 Prospect St. Wakefield Ma 01880 pdaelectrical@outlook.com 781-438 2324 PROJECT: 107 BRIDGE STREET SALEM, MA Fire Equipment Cut Sheets ES -sox Intelligent Addressable FACP with Communicator DF-60953:C Fire -tile Alarms by Honeywell Addressable Fire Alarm Control Panels General The ES-50X is the latest intelligent addressable fire alarm control panel (FACP) from Fire•Lite Alarms and is a direct replacement for the MS-9050UD/LS. The ES-50X comes with a pre -installed communi-cator and supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the ES-50X programs just like Fire•Lite's other addressable panels, yet fits into applications previously served only by conventional panels. The pre -installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC toss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL -MOD or CELL -CAB -FL. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk -test data, current status and system volt- ages by means of a USB flash drive. The power supply and ail electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTMF). Features • Listed to UL Standard 864, 10th edition • Pre -installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator • Optional CELL -MOD or CELL -CAB -FL GSM Central Station Communicator over AlarmNet® • Compatible with SWIFT® wireless devices • Auto -programming (learn mode) reduces installation time. Reports two devices set to the same address Two independently programmable, built-in Style Z (Class A) or Style Y (Class B) NAC circuits Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices • Notification Appliance Circuit End of Line resistor matching • Four programmable function keys for ease of maintenance • Two programmable relays and one fixed trouble relay • Ruilt-in Programmer • Integral 80-character LCD display with backlighting • Real-time clock/calendar with automatic daylight savings control • History file with 1,000 event capacity • Addressable sounder base • Multi -criteria detector (smoke, heat, CO) with programmable response • Control module delay timer • Automatic detector sensitivity testing (NFPA 72 compliant) • Automatic device type -code verification • Point trouble identification • Waterflow selection per module point • Alarm verification selection per detector point • Maintenance alert warns when smoke detector dust accumula- tion is excessive • One -person audible or silent walktest with walktest log & printout • System alarm verification selection per detector point • PAS (Positive Alarm Sequence) and Pre -signal per point (NFPA 72 compliant) • Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP • Supports LiteSpeedTM and CLIP protocols • SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire • Single addressable SLC loop which meets NFPA Class B and Class A requirements • 50 addressable device capacity (any combination of addressable defectors and modules) • Compatible with Fire•Lite's addressable devices (refer to the SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NACS) ▪ Two independently programmable output circuits_ Circuits can be configured for the following outputs: — Style Y (Class B) — Style Z (Class A) • Silence Inhibit and Autosilence timer options • Continuous, March Time, Temporal, or California code for main circuit board NACs with two -stage capability • Selectabis strobe synchronization per NAC • 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A PROGRAMMING AND SOFTWARE • Autoprogramming (learn mode) reduces installation time DF-60953:C • 7/16/2O18 — Page 1 of 4 AD355: Low -profile, intelligent, "Adapt" multi -sensor detector (B350LP base included). 8200S: Programmable, addressable sounder base B200SR: Addressable sounder base. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. D355PL: InnovairFlex low -flow non -relay duct -detector housing; includes SD355R. DNR: InnovairFlex low -flow non -relay duct -detector housing. (Order SD355R/SD365R separately.) DNRW: InnovairFlex low -flow non -relay duct -detector housing, with NEMA-4 rating. Watertight. (Order SD355RISD365R separately.) Addressable Modules MMF-300: Addressable Monitor Module for one zone of normally - open dry -contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end -of -line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300. Addressable Monitor Module for one zone of conventional two -wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style YIZ (Class B/ A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pelf station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). ISO-6: Six -fault isolator module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SMB500: Used to mount all modules except MMF-301 and M301. MMF-300-10: Ten -input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six --zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six -circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB -OF cabinet. CRF-300-6: Six -relay control module (Form-C relays). Mount one or two modules in a BB--2F cabinet (optional). Mount up to six modules on a GHS-6 chassis in a BB-6F cabinet. SWIFT Wireless Devices W-GATE: LiteSpeed Wireless Gateway W-SD355: LiteSpeed intelligent, wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135°) heat detector. W-SD355T: intelligent wireless photo/heat detector. W-H355: LiteSpeed intelligent wireless fixed -temperature (135°) heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module. W-CRF: LiteSpeed Intelligent wireless relay module. W-BG12LX: LiteSpeed Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices_ Available for download from firelite.com. NOTE For more information on Compatible Addressable Devices for use with the ES-50X, see the following data sheets (document num- bers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 (DF-52386), BG-12LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/CRF Series (DF-52130), CP355 (DF-52383), H355 Series (DF-52385), 1300 (DF-52389), 150-6 (DF-60485), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DP-52347), MMF-302-6 (DF-52356), SD355/SD355T (DF-52384), and SLC Wiring Manual (51309). NOTE: Legacy 300 Series detection devices such as the CP300/CP350, SD300(T)/SD350(T) and older modules such as the M300, M301, M302, C304, and BG-10LX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. ADDRESSABLE DEVICE ACCESSORIES End -of -Line Resistor Assembly (R-47K and R-3.9K): The 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, and CMF-300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted -pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. OF-60953:C • 7/16/201 B— Page 3 of 4 DF-60963: B SD355C0 Addressable Photoelectric Smoke/CO Detector General World -class fire and carbon monoxide (CO) detection combined in a single addressable device provides a practical solution for today's market. The SD355C0 Advanced Multi -Criteria Fife/CO Detector is a plug- in, addressable device that provides both fire and carbon monoxide (CO) detection. For fire, the detector combines four separate sens- ing elements in one unit (smoke, CO, light/flame, and heat) to sense multiple components of a fire. This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particu- late. For CO, the detector's electrochemical sensing cell creates a separate signal for life safety CO detection. CO is a colorless, odorless, and deadly gas that is virtually impossi- ble to detect with the human senses. It is released whenever car- bon -based fuels (from fossil fuels to firewood) burn without enough oxygen to form CO2. Because the potential exists for dangerous lev- els of CO to accumulate in almost any building, legislation mandat- ing the use of CO detection in commercial spaces continues to increase across the U.S.The SD355C0 is listed to the UL 268 stan- dard for smoke detectors and the UL 2075 standard for system -con- nected life safety carbon monoxide monitoring. The SD355C0 should be used in conjunction with the B200S intelli- gent sounder base, which can generate either a Temporal 3 pattern for fire or a Temporal 4 pattern for CO alarm indication. The SD355C0 can also be used with the B21OLP 6" standard base, the B501 4" standard base, the B224B1 base, or the B224RB relay base. NOTE: The 50355C0 is compatible with the ES-50X(C) and ES-200X(C) fire alarm control panels. Features • Unique ability to detect all four major elements of a fire: smoke, CO, heat, and light/flame • Separate CO detection signal • Highest nuisance alarm immunity • Automatic drift compensation of smoke sensor and CO cell • Uses only one address on the SLC • RealTest0 CO testing capability • Separates audible signal for fire or CO alarm when used with the 82005 base • CO cell end -of -life warning and fault • LiteSpeedTm operation Specifications PHYSICAL SPECIFICATIONS Size: 3.46" (8.79 cm) high x 6 875" (17.46 cm) diameter installed in B200S base Shipping weight: 4.6 oz. (130.41 g) Color: Ivory Operating humidity range: 15% — 90% relative humidity (non -con- densing) Operating temperature: 32°F to 100°F (0°C to 38°C) Air velocity: 0 — 4000 ft./min. (0 to 20 m/sec.) Flre-t re-ALarms by Honeywell Addressable Devices ELECTRICAL SPECIFICATIONS Operating Voltage range: 15 — 32 volts VDC. Standby current (max. avg.): 300 pA @ 24 VDC (one communica- tion every 5 seconds with LED blink enabled). Maximum Alarm Current (LED on): 7.2 mA @ 24 VDC. CO ALARM ACTIVATION LEVELS Alarm activation levels as defined by UL Standard 2034: Concentration of CO Maximum Alarm Time Response 70 (+1- 5) PPM 240 min (not less than 60 min) 150 (+1- 5) PPM 50 min (not less than 10 min) 400 (+1- 10) PPM 15 min (not less than 4 min) Ordering Information • SD355CO: Advanced Multi -Criteria photoelectric smoke/CO detector • B210LP: Standard base • B200S: Sounder base • B224RB: Relay base • B244B1: isolator base • B501: Base without flange • M02-04-00: Detector test magnet • M02-09-00: Telescoping test magnet Agency Listings and Approvals The listings and approvals below apply to the SD355CO. In some cases, certain modules may not be listed by certain approval agen- cies, or listing may be in process. Consult the factory for the latest list- ing status. • UL: S1059 • CSFM: 7275-0075:0505 dF-60963:B • 412712018 — Page 1 of 2 Operating temperature range: • SD365(A): 0°C to 50°C (32°F to 122°F); • SD365T(A): 0°C to 38°C (32°F to 100°F). • SD365R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158° F). Relative humidity: 10%-93%, non -condensing. Listings Listings and approvals below apply to the SD365 Series detectors. In some cases, certain detectors may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC Listed: S1059 • CSFM: 7272-0075-0502 • FM Approved Product Line information NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. NOTE: `7V" suffix indicates LiteSpeed() and CLIP device. NOTE: A" suffix indicates Canadian version. SD365(A): White, Addressable photoelectric detector; B300-6 base included. LiteSpeed only. SD365(A)-IV: Ivory, Addressable photoelectric detector; B300-6 base included. SD365T(A): White, Same as SD365 but with thermal element; B300-6 base included. LiteSpeed only. SD365T(A)-IV: Ivory, Same as SD365 but with thermal element; B300-6 base included. SD365R(A): White, Remote test capable addressable photoelectric detector for use with DNR(A)/DNRW. LiteSpeed only. SD365R(A)-IV: Ivory, Remote test capable addressable photoelec- tric detector; for use with DNR(A)/DNRW. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low -profile mounting base. (CSFM: 7300-1653:0109 Pending) B300-6-IV: Ivory,6" base, standard flanged low -profile mounting base. (CSFM: 7300-1653:0109 Pending) B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low -profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109 Pending) B501-IV: Ivory color, 4" standard European flangeless mounting base. ULJULC listed. (CSFM: 7300-1653:0109 Pending) B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. 13224RB-WH: White, relay base. (CSFM: 7300-1653:0216 Pending) 13224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216 Pending) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224B1-WH: White, isolator detector base. (CSFM: 7300- 1653:0216 Pending) B224B1-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216 Pending) B224B1A-WH: White, isolator detector base, ULC listing. B224BIA-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213 Pending) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653.0213 Pending) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653.0238 Pending) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 Pending) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213 Pending) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653.0213 Pending) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238 Pending) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A) base. TR300-IV: Ivory, replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501(A) and B300- 6(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: Color Kit (includes cover and trim ring), white, 10-pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack. CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack. DF-61 o10:A • 4/4/18 — Page 2 of 3 DF-60059:I - E-265 Intelligent Bases Standard, Relay, Isolator, Sounder, and Low -Frequency Sounder Bases General To meet local code and application requirements, Fire-Lite offers standard 4" and 6" bases, as well as, specialty base designs includ- ing relay, isolator, sounder and low frequency sounder options for the new 365 Series of addressable detectors as well as previous generations. The standard 4" and 6" bases offer a plug-in detector base intended for use in intelligent systems, with screw terminals provided for power (+ and —), and remote annunciator connections. Communica- tion takes place over the power (+ and —) lines. The 4" base offers a compact design while the 6" base provides compatibility with a wider range of junction boxes. The specialty bases support application driven requirements. These bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface -mount boxes. The mounting plate enables pre -wiring of all connections to speed and simplify installation. Relay bases (B224RB-WHIB224RB-I1/) provide one form-C contact relay for control of auxiliary functions, such as door closure and ele- vator recall. The relay can operate in two different modes (short and long delay). The activation time for the short delay is 60-100 milli- seconds, while the activation time for the long delay is 6-10 sec- onds. A shunt with pin headers, located on the base PC board, is used to set the delay timing. Isolator bases (B224BI-WHIB224B1-IV) allow the Signaling Line Cir- cuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being dis- abled. The base isolates the section of the loop containing the short circuit from the remainder of the circuit and automatically restores when the fault is corrected. Sounder and low frequency (-LF) sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent. Studies show that a lower fre- quency, centered around 520 Hz, is the most ideal to wake sleeping occupants, even those with mild to severe hearing loss. The B200SR sounder and -LF sounder bases (B200SR-WH/ B200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B50113H Series sounder base installations. The device enables users to select one of two B501-supported tones (ANSI Temporal 3 or Continuous) through a jumper. The B2005 sounder and -LF sounder bases (B2005-WH/B200S-IV/ B200S-LF-WHIB200S-LF-IV) adopt the same address as the detec- tor, but use a unique device type on the [oop_ The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder — or a group of sounders — to activate. The command set from the FACP can be tailored to multiple event -driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, ANSI Temporal 4, or March Time) and group. In addition, some FACPs will enable custom tone patterns. The B2005 series sounder bases recognize the System Sensor synchronization protocol. This enables them to be used as a component of the general evacuation signal — along with other System Sensor AV appliances — when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. Flre vreALarms by Honeywell B300(A)-6 Standard 6" Base (White) B200S(A)-W1-1 Sounder Base (White) B501-WHITE Flangeless 4" Base (White) Addressable Devices B300(A)-6-IV Standard 6" Base (Ivory) • • B200S-LF-WH Low - Frequency Sounder Base (White) B501-BL Flangeless 4" Base (Black) Specifications NOTE: Specifications applies to all mode! variants "A", "-BL , "-LF", "-IV, -WH, -WHITE. See Product Line Information for detailed model descrip- tion. Diameter • B501-WHITE: 4" (10.16 cm) diameter. • B300-6: 6.1" (15.49 cm) diameter. • B224BI, B224RB: 6.2" (15.748 cm) diameter. - B200S, B200SR: 6.875" (17.46 cm) diameter. Wire gauge: • B224B1, B224RB: 14 to 24 AWG. - B300-6, B501, B200S, B200SR: 12 to 24 AWG Temperature range: • B224BI, B224RB, B200S, B200SR: 32°F to 120°F (0°C to 49°C). • B300-6, B501: -4°F to 150°F (-20°C to 66°C). Humidity range: 10% to 93% RH, non -condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1 °F) per ULC_ OF-60059:1 • 7/18/2018 —Page 1 of 3 However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tem- perature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Electrical Ratings FOR B300-6 SERIES BASES: Operating voltage: 15 to 32 VDC Standby current: 170 pA maximum FOR B501 SERIES BASES: Operating voltage: 15 to 32 VDC Standby current: 150 pA maximum FOR B200 SERIES BASES: External supply voltage: 16 to 33 VDC (FWR) Standby current: 500 pA maximum. Alarm current: B200S(A)(-IV)(-WH) - 35 mA maximum at high -volume setting - 15 mA maximum at low -volume setting B200S-LF(-IV)(-WH) High -volume setting: - 70 mA maximum @ 33.0 VDC - 90 mA maximum @ 24.0 VDC - 140 mA maximum @16.0 VDC • B200S-LF(-IV)(-WH) Low -volume setting: - 15 mA maximum @ 33.0 VDC - 20 mA maximum @ 24.0 VDC - 25 mA maximum @ 16.0 VDC • B200SR(A)(-JV)(-WH) - 35 mA maximum • B200SR-LF(-IV)(-WH) - 65 mA maximum @ 33.0 VDC - 90 mA maximum @ 24.0 VDC - 125 mA maximum @16.0 VDC SLC operating voltage: 15 to 32 VDC SLC standby current: See applicable sensor specification. Sound output: Greater than 85 dBA minimum; measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) FOR B224BI, B224RB (A) (-AO (-WH): Operating voltage: 15 to 32 VDC (powered by SLC) Standby ratings: <450 pA maximum @ 24 VDC Set time (B224RB(A)(-IV)(-WH) only): short delay 60-100 millisec- onds; long delay 6-10 seconds Reset time (B224RB(A)(-IV)(-WH) only): 20 milliseconds maximum Relay characteristics (B224RB(A)(-IV)(-W11) only): two -coil latch- ing relay; one Form-C contact; ratings (UL/CSA): 0.9 A @ 125 VAC, 0.9 A @ 110 VDC, and 3.0 A @ 30 VDC Product Line Information INTELLIGENT BASES NOTE: 'A" suffix indicates ULC Listed model. NOTE: " 1V" suffix indicates Ivory color model. NOTE: " BL" suffix indicates Black color model. NOTE: "-MI" and "-WHITE" suffix indicates White color model. B300-6: White, 6" base, standard flanged low -profile mounting base; replacement for B210LP. B300A-6: Same as B300-6, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10; replace- ment for B210LPBP. B300-6-IV: Ivory,6" base, standard flanged low -profile mounting base. B300A-6-IV: Ivory, 6" standard flanged low -profile mounting base, ULC listed. B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed_ B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B501-BL: Black, 4" standard European flangeless mounting base. ULIULC listed. 8501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listed. B224RBA-IV: Ivory, relay base, ULC listed. 1322481-WH: White, isolator detector base. B224BI-IV: Ivory isolator detector base. B224B1A-WH: White, isolator detector base, ULC listed. B224B1A-IV: Ivory isolator detector base, ULC listed. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses LiteSpeedTM protocol. B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses LiteSpeedTM protocol. B200SA-WH: Same as B200S-WH, ULC listed. B200SA-IV: Same as B200S-IV, ULC listed. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +7- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA72 sleeping space requirement. B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH, ULC listed. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listed. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the Page 2 of 3 — DF-60059:1 • 7/18/2018 NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B300(A)-6 bases. TR300-IV: Ivory, replacement flange for 8300(A)-6-IV bases. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501(A) and B300(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: White, detector color kit. Pack of 10. CK300-IV: Ivory, detector color kit. Pack of 10. CK300-BL: Black, detector color kit. Pack of 10. Junction Box Selection Guide Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL/ULC Listed: S911 • FM Approved • CSFM: 7300-1653:0109, 7300-1653:0126, 7300-1653:0213, 7300-1653:0238 Rase Models Single Gang Double Gang 3.5" Oct. 4.0" Oct. 4.0" Sq. 4.0" Sq. with 3.0" mud ring 50 mm 60 mm 70 mm 75 mm 6200S, B200SR Yes Yes Yes Yes Yes Yes No No No No B501 No No Yes No No Yes Yes Yes Yes No B300-6 Yes No Yes Yes Yes Yes No No No No B224B1, B224RB Yes Yes Yes Yes Yes Yes No No No No NOTE: Box depth contingent on base and wire size. Refer to National Electric Cade or applicable local codes for appropriate recommendations. NOTE: Applies to all model variants 'A", "-8L" "-LF", "-IV", "-WI-I", and "-WHITE". See Product Line Information for detailed model description. LiteSpeed'" is a trademark; and Fire•Lite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 GIEFCTAIIPIIEED 9YLIF HIINCgMANIFACilfIN6 QUALITY SYSTEMS This docurnent is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice, For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Country of Origin: Mexico Page 3 of 3 — DF-60059:1 • 7/18/2018 SYSTEM SENSOR` Mini -Horns The SpectrAlertt Advance series of mini-hom sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features • 12 and 24V operation • High and low volume settings • Temporal and non -temporal tones • Mounts to single gang back box • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series Mini-AlertTM sounders • Listing for ceiling or wall mounting Agency Listings LISTED 54011 APPROVED 3028007 n735-'1653:196 SPECTRAlert diraraf The MHR and MHW mini -horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini -horns offer high and low volume settings, and temporal or non -temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini -horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL. 464 for fire protective signaling systems. *Th, SYSTEM SENSOR? Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use Agency Listings SICNA[ING u5Teo 05512 84071 APPROVED FM approved except 1125~1553,1224 tor ALERT models 7135-155306d3 3057383, 3057072 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AV088E5-05.212212018 • Page 1 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 8--17.5 Volts 16-33 Volts UL Max. Horn Current Draw (rnA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non -Temporal High 43 47 54 95 N/A 121 155 Non -Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 NIA 222 257 3.1 KHz Non -Temporal High 42 43 54 DC FWR 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (mA RMS), Wall Horn Strobe, Candela Range (15-185 cd) DC Input Temporal High 8-175 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non -Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non -Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern 1 Temporal 2 Temporal 8-17.5 16-33 Volts Volts dB DC DC FWR High 84 89 89 Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9* Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes, Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. AVDSOO5-05 • 2/2212018 • Page 3 CORPORATION aes-corp.com ,{sICURITY INNOVATION Smart Subscribers for Commercial Fire Alarm Systems 7788F/7744F Series Fire Subscribers Features • AES-InteiliNet" smart mesh radio networks are self -forming, self -healing, and highly scalable • AES-lntelliNet alarrn communications technology never sunsets compared to cellular alternatives • Each Smart Subscriber enables multiple paths to a central monitoring station • Option to transmit full data from FACP digital dialer to AES-MultiNet receiver i Simple and fast activation an AES-IntelllNet network Benefits • Most stable and profitable fire alarm communication technology • Net.work owner -operators retain virtually all RMR • Meets UL 864 Commercial Fire Alarm requirements for primary standalone communication • Ideal drop -in full -function replacement for phone lines • Universal wireless Smart Subscriber Transceivers support all new and legacy FACPs Advanced Wireless Fire Alarm Monitoring AES 7788F/7744F Series Subscribers are the ideal universal wireless communicators for any new or existing fire alarm system. AES-IntelliNet networks are built using AES Corporation's patented mesh radio communications technology. A Smart Subscriber at each alarm site acts as transmitter, receiver, and repeater of alarm signals across the network. This creates a smart long-range radio network with multiple pathways between each alarm site and the central receiver. Multiple pathways mean multiple redundancies assuring the most reliable delivery of signals and compliance with rigorous industry standards. AES-lntelliNet networks self -adjust to network changes and assure that signals automatically follow the shortest path available as the network of Subscribers grows. Highest Long Term Stability and Profitability AES-IntelliNet remains the most stable and profitable fire alarm communication technology available today in the rapidly changing world of communications. AES private wireless networks never sunset compared to cellular technology and traditional phone lines. AES-IntelliNet networks maximize RMR generated from network alarm communication services because signals are delivered without the need for a costly operations center or cellular service providers. Cost Free Supervised Operation AES Subscribers offer fully -supervised operation that includes monitoring of primary and back-up operating power as well as the radio connection to the AES-lntelliNet network. Each Subscriber performs "Check -ins" with the AES central station receiver at least once every 24 hours which complies with the UL 864 standard for commercial fire alarm communications. The supervision Check -in time can be set to as often as needed for the application. Because the central station owns and operates the long-range wireless network, there is no cost for air time to transmit supervisory signals. This is very different from cellular alternatives which require an aggressive supervision Check -in schedule in order to comply with UL 864 listing. The high monthly cost for cellular service fees significantly reduce RMR profit. Unlike cellular, there is no cost for air time to transmit supervisory signals. Full Data Module Option - Ideal replacement for Phone Lines AES Subscribers transmit consolidated alarm, trouble, and supervisory signals triggered by a FACP output relay. Subscribers with an integrated AES-IntelliPro Fire full data module transmit full alarm zone and event codes captured from a panel's digital communicator. Both options individually meet UL and NFPA 72 requirements. AES Fire Subscribers with built-in full data module are the ideal drop -in full -function replacement for phone lines for communicating signals from both new and existing UL commercial fire alarm systems. Replacing phone lines with AES-IntelliNet maximizes RMR profit with significant bottom line impact, unlike with cellular technologies that charge high monthly service fees. How to Order 7788F 7744F 7788F-ULP 7744F-ULP 7788 F-ULP-P 7744F-ULP-P 7788 F-C 7788 F-C-ULP 7794 7795 7742 AES Fire Subscribers 8 Zone Fire Subscriber, 8 Supervised Zones, Red Enclosure. 4x4 Zone Fire Subscriber, 4 Reversing Polarity, 4 Supervised Zones, Red Enclosure. 8 Zone Fire Subscriber, 8 Supervised Zones, includes 7794AE5-lntelliPro Fire, Red Enclosure. 4x4 Zone Fire Subscriber, 4 Reversing Polarity, 4 Supervised, includes 7794AE5-lntelliPra Fire, Red Enclosure. 8 Zone Fire Subscriber, 8 Supervised Zones, includes 7795 AES-InteliiPro Fire, Red Enclosure. UL listed for primary standalone communication with fire radios. 4x4 Zone Fire Subscriber, 4 Reversing Polarity, 4 Supervised Zones, includes 7795 AES-IntelliPro Fire, Red Enclosure. UL listed for primary standalone communication with fire radios. 8 Zone Fire Alarm Subscriber. ULC listed for Canada. 7788F-C Fire Alarm Subscriber with.AES-Thie.1I/Pro Fire full data module. ULC fisted f'or Canada. Add -on AES-intelliPro Fire Modules AES-IntellrPro Fire Fuli Data Module, UL listed for supplemental communication with fire radios. AES-InteiliPro Fire Full Data Module (7794) with 7762 Hardware Supervisory Module and 7740 AES Local Annunciator. ILL listed for primary standalone communication with fire radios. 7762 Hardware Supervisory Module and 7740 AES Local Annunciator. 7762 module provides power and supervision of the 7740 ALS Local Annunciator AES Local Annunciator 7740 7740 AES Local Annunciator. UL listed for use with 7795 module or 7742 module.