107 BRIDGE STREET - FPJob: RENOVATED RESIDENTIAL BUILDING Address: 107 BRIDGE STREET City: SALEM Contract #: 4807 Contractor: TO BE DETERMINED Address: City: State: MA Date: Designer: Zip/Postal Code: 01970 3/25/2019 JFP SOLUTIONS, INC. State: Zip/Postal Code: Phone: Fax: Email: Approving Authority: SALEM FD Design Defaults Default Sprig Size: Default Sprig Material: Default Sprig Elevation: Standards: NFPA 13R 1 CPVC 0 Default Drop Size: 1 Default Drop Material: CPVC Default Drop Elevation: 0 FIRE PROTECTION NARRATIVE / NOTES: MAX. HANGER SPACING PIPE TYPE NOMINAL PIPE SIZE (IN) 1 11'4" 11'2" 2 21'2 " 4 6 8 SCH 10,40 STEEL 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 UL LISTED CPVC 6-0 6-6 7-0 8-0 9-0 36" MAX. FOR 1' DIA. [48» MAX. FOR 1 1/4" DA.60" MAX. FOR 1 1/2" DIA. OR LARGER / DISTANCE BETWEEN OMIT NCR ON STARTER PIPES SHALL NOT EXCEED 6' OR LESS, NO X-MAIN HGR ABOVE TABLE OMISSIONS ALLOWED IF GREATER THAN 36" MAX. FOR 1" DIA. - IF GREATER THAN 48" MAX. FOR 1 1/4" DIA. IF GREATER THAN 60" FOR 1 1/2" DIA. OR LARGER - - THE PURPOSE OF THIS FIRE PROTECTION DRAWING AND THE ASSOCIATED HYDRAULIC CALCULATIONS IS TO INDICATE THE PROPOSED RESIDENTIAL SPRINKLER SYSTEM TO BE INSTALLED WITHIN THE RENOVATED MULTI -UNIT BUILDING LOCATED AT 107 BRIDGE STREET IN SALEM, MASSACHUSETTS. THIS EXISTING BUILDING IS COMPRISED OF A BASEMENT, FIRST FLOOR, SECOND FLOOR AND THIRD FLOOR AS INDICATED ON THE ARCHITECTURAL DRAWINGS. INTERIOR MODIFICATIONS TO THE LAYOUT WILL CONVERT THE BUILDING TO 4 RESIDENTIAL UNITS. THE BASEMENT WILL CONTAIN UTILITY AND STORAGE SPACE FOR THE BUILDING OCCUPANTS. THIS RESIDENTIAL SPRINKLER SYSTEM HAS BEEN DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13R (2013 EDITION) FOR A RESIDENTIAL BUILDING UP TO 4 STORIES IN HEIGHT AND NOT EXCEEDING 12,000 GROSS SF. THE SPRINKLER CONTRACTOR SHALL FOLLOW THE LATEST REQUIREMENTS OF NFPA 13 AND 13R (2013 EDITION), MASSACHUSETTS STATE BUILDING CODE AND SALEM FIRE DEPARTMENT REQUIREMENTS. THIS SYSTEM WILL BE SUPPLIED BY A NEW 2" COPPER SERVICE, TAPPED OFF THE EXISTING WATER MAIN ON ARBELLA STREET. THE 2" SERVICE SHALL BE INSTALLED, FLUSHED AND TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 24 BY A LICENSED UNDERGROUND CONTRACTOR AND WILL ENTER THE BASEMENT AS INDICATED ON THIS DRAWING. THE SYSTEM HAS BEEN HYDRAULICALLY CALCULATED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13R, INCLUDING THE FOUR HYDRAULICALLY MOST DEMANDING HEADS IN A SINGLE COMPARTMENT BASED ON THE REQUIREMENTS OF THE SPECIFIC SPRINKLER HEAD AND THE SPACING USED IN THIS DESIGN (18'x18' REQUIRING A MINIMUM OF 18 GPM @ 13.5 PSI). THE BASEMENT HAS BEEN CALCULATED AS AN ORDINARY HAZARD GROUP I OCCUPANCY PER NFPA 13 REQUIREMENTS FOR AREAS OUTSIDE LIVING SPACES. REMOTE AREAS, DENSITIES AND HOSE STREAM ALLOWANCES ARE INDICATED ON THIS DRAWING. SYSTEM DEMANDS HAVE BEEN COMPARED TO HYDRANT FLOW DATA OBTAINED FROM THE WATER DEPARTMENT. COPIES OF THE CALCULATIONS HAVE BEEN SUBMITTED WITH THESE DRAWINGS TO THE SALEM FIRE AND BUILDING DEPARTMENTS FOR REVIEW. INSTALLATION NOTES: ALL WORK SHALL BE PERFORMED BY A MASSACHUSETTS LICENSED SPRINKLER CONTRACTOR. THE SPRINKLER CONTRACTOR SHALL FOLLOW THE LATEST REQUIREMENTS OF NFPA 13R (2013 EDITION), MASSACHUSETTS STATE BUILDING CODE (9TH EDITION) AND THE SALEM FIRE DEPARTMENTS. THE ARCHITECTURAL BACKGROUND OF BUILDING MAY DIFFER SLIGHTLY FROM ACTUAL LAYOUT. DRAWINGS ARE NOT INTENDED TO SHOW ALL OFFSETS AND PIPING ELEVATION CHANGES. CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS PRIOR TO FABRICATION. CONTRACTOR SHALL HYDROSTATICALLY TEST ALL SPRINKLER PIPING AT 200 PSI FOR 2 HOURS AND IS RESPONSIBLE FOR THE COMPLETION OF ALL ABOVE GROUND TEST CERTIFICATES, SUPPLIED TO THE OWNER. ALL PIPING INSTALLED ON THE FIRST, SECOND AND THIRD FLOORS SHALL BE UL LISTED CPVC SPRINKLER PIPING. ALL PIPING INSTALLED WITHIN THE BASEMENT UTILITY SPACE SHALL BE BLACK STEEL PIPING. ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13 (2013 EDITION) AND ALL MANUFACTURERS INSTALLATION RECOMMENDATIONS. ALL PIPING SHALL BE PITCHED TO DRAIN WITH LOW -POINT DRAINS AT SECTIONS OF PIPING SUBJECT TO WATER TRAPPING. SPRINKLER CONTRACTOR SHALL PROVIDE PROTECTIVE PLATES WHERE CPVC PIPING IS RUN THROUGH STUDS TO PREVENT PUNCTURING OF THE SPRINKLER PIPING DURING DRYWALL INSTALLATION AS REQUIRED BY NFPA STANDARDS. ALL SPRINKLER HEADS THROUGHOUT THE UPPER LEVELS WILL BE RESIDENTIAL PENDENT HEADS. ALL SPRINKLER HEADS WITHIN THE BASEMENT LEVEL WILL BE QUICK -RESPONSE COMMERCIAL UPRIGHTS. ALL HEADS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS AND THE REQUIREMENTS OF NFPA 13 (2013 EDITION). THE BUILDING OWNER IS RESPONSIBLE FOR MAINTAINING THIS SPRINKLER SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 25, INCLUDING THE PROVISION OF HEAT IN ALL AREAS CONTAINING SPRINKLER PIPING AND HEADS TO PREVENT PIPE FROM FREEZING. ANY AREAS THAT RAISE CONCERN WITH REGARD TO FREEZING POTENTIAL DURING INSTALLATION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING PRIOR TO BEING INSTALLED. JFP SOLUTIONS, INC. AND THE ENGINEER OF RECORD TAKE NO RESPONSIBILITY FOR ANY DAMAGES CAUSED BY FREEZE UPS. WOOD JOIST CONSTRUCTION RESIDENTIAL CONCEALED SPRINKLER HEAD (K=4.9) TYPICAL MAINTAIN NFPA 13 OBSTRUCTION CRITERIA (TYPICAL) CPVC MAIN LOCATED WITHIN HVAC SOFFIT FEEDING BRANCHLINES LOCATED WITHIN JOIST CHANNELS (TYPICAL) GYPSUM BOARD CEILING ON WOOD STRAPPING TYPICAL RESIDENTIAL PENDENT SPRINKLER INSTALLATION NOT TO SCALE 2 )/ GROOVED CHECK WITH BALL DRIP 2 Y2" SYSTEM FEED 2 %2" STRAIGHT -PIPE RISER WITH FLOW SWITCH, PRESSURE GAUGE AND COMBINATION TEST $ DRAIN 21/2" AMES C200 BACKFLOW PREVENTER WITH MONITORED BUTTERFLY VALVES) 2"x 2/2" VIC-FLANGE 211 x 2'-0 GALVI (THD BY THD) THROUGH WALL WITH 45° EL AND WALL PLATE 40 2 %2" GROOVED TEE WITH CAP (FOR FORWARD FLOW TESTING OF BACKFLOW) PROPOSED 2" FIRE SERVICE (INSTALLED, FLUSHED, TESTED $ CUT TO HEIGHT, BY OTHERS) RISER DETAIL SCALE: NOT TO SCALE TABLE 8.10.6.1.2 POSITIONING OF SPRINKLER TO AVOID OBSTRUCTION TO DISCHARGE DISTANCE FROM SPRINKLERS TO SIDE OF OBSTRUCTION (A) MAXIMUM ALLOWABLE DISTANCE OF DEFLECTOR ABOVE BOTTOM OF OBSTRUCTION (INCHES) (B) LESS THAN 1 FT 0 1'-0" TO LESS THAN 1'-6" 0'-0" 1'-6" TO LESS THAN 2'-0" 0'-1" 2'-0" TO LESS THAN 2'-6" 0'-1" 2'-6" TO LESS THAN 3'-0" 0'-1" 3'-0" TO LESS THAN 3'-6" 0'-3" 3'-6" TO LESS THAN 4'-0" 0'-3" 4'-0" TO LESS THAN 4'-6" 0'-5" 4'-6" TO LESS THAN 5'-0" 0'-7" 5-0" TO LESS THAN 5'-6" 0'-7" 5'-6" TO LESS THAN 6'-0" 0'-7" 6'-0" TO LESS THAN 6'-6" 0'-9" 6'-6" TO LESS THAN 7'-0" 0'-1 1 " 7'-0" AND GREATER 1'-2" CLOSETS (TYPICAL) EXCEPT WHERE SPECIFIED IN SECTION 6.6.4 (NFPA 13R, 2013 EDITION), SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING CONDITIONS: 1) THE AREA OF THE SPACE DOES NOT EXCEED 24 SF 2) THE LEAST DIMENSION DOES NOT EXCEED 3 FT 3) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED IN NFPA 220. NOTE: WHEN MECHANICAL EQUIPMENT OR LAUNDRY MACHINES ARE PLACED IN THE CLOSET, THE CLOSET IS NO LONGER CONSIDERED A CLOTHES CLOSET, LINEN CLOSET, OR PANTRY, SO THE EXCEPTION OF 6.6.3 IS NO LONGER VALID AND SPRINKLERS MUST BE INSTALLED. CEILING OBSTRUCTION A FIGURE 8.10.6.1.2(A) POSITIONING OF SPRINKLERS TO AVOID OBSTRUCTION TO DISCHARGE Calculation results for Design Area 2 BASEMENT This system as shown on TO BE DETERMINED company print no for RENOVATED RESIDENTIAL BUILDING at 107 BRIDGE STREET dated 3/25/201 contract no 4807 is designed to discharge at a rate of 0.15 gpm/ft2 (L/min/m2) of floor area over a maximum area of 1282 ft2 when supplied with water at a rate of 355.7 gpm at 74.6 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: ORD HAZ I Commodity classification: Maximum storage height: Storage arrangement: Number of heads flowing: 17 System Type: Wet Maximum velocity: 37.87 ft/s Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: 0 gpm 355.7 gpm 0 gpm 0 gpm 0 gpm 355.7 gpm 250 gpm 605.7 gpm NFPA 13 TABLE 8.10.6.1.2 + FIGURE 8.10.6.1.2(A) RESIDENTIAL PENDENT AND UPRIGHT SPRAY SPRINKLERS ELECTRIC BELL WITH BACKER -BOX (WIRED BY OTHERS) 2 %2" x 2'-0 GALVI (THD BY GROOVE) THROUGH WALL SINGLE INLET 2-1/2" FIRE DEPARTMENT CONNECTION (COORDINATE WITH LOCAL FD PRIOR TO INSTALLATION) 2" DRAIN PIPED TO EXTERIOR Design Area 2 Wet System BASEMENT Demand Calculations using Hazen -Williams Method Occupancy Classification: ORD HAZ I Design Area Density: 0.15 Additional Outside Hose: 250 Design Area Size: 1282 Notes: THIS CALCULATION INCLUDES THE HMD 1282 SF OF UTILITY SPACE WITHIN THE BASEMENT LEVEL Pressure Required at Source: Pressure Available at Source: Surplus Pressure at Source: 1 12" RISER UP FROM GROUND LEVEL AND UP TO THIRD (VERIFY LOCATION IN -FIELD) Bedroom &If. VAW -812 Bedroom vi. 112 5-7 CIAP 2-11 ..,_ Unit 4 Bathroom do 0 \/ /\ UD 4tato ., 1 Stairs /\ 2 n 1 1 1 1 1 1 <S8> L. 4-52. S-412 11<0 031 -7 do Staf s 74.6 psi 82.7 psi 8.1 psi Calculation results for Design Area 1 - THIRD FLOOR UNIT This system as shown on TO BE DETERMINED company print no for RENOVATED RESIDENTIAL BUILDING at 107 BRIDGE STREET dated 3/25/201 contract no 4807 is designed to discharge at a rate of 0.05 gpm/ft2 (L/min/m2) of floor area over a maximum area of 326 ft2 when supplied with water at a rate of 75.2 gpm at 55.5 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: RES 13R Commodity classification: Maximum storage height: Storage arrangement: Number of heads flowing: 4 System Type: Wet Maximum velocity: 12.28 ft/s Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: 0 gpm 75.2 gpm 0 gpm 0 gpm 0 gpm 75.2 gpm 100 gpm 175.2 gpm Bedroom 0 J Pressure Required at Source: Pressure Available at Source: Surplus Pressure at Source: 3-612 Bathroom N rs- ■ 6-10 0 111111kill' � e� W 7-1 U 0 PROVIDE QUICK -RESPONSE UPRIGHT SPRINKLERS THROUGHOUT BASEMENT STORAGE / UTILITY AREA. ALL PIPING WITHIN BASEMENT LEVEL TO BE BLACK STEEL. 3_012 Unit 3 1 12" RISER UP TO GROUND LEVEL (VERIFY LOCATIONS IN -FIELD, TRANSITION TO CPVC ONCE LEAVING ORDINARY HAZARD BASEMENT AREA, TYPICAL) 2 Kitchen 4t CO 112 0'� 1-412 %ak 0-11 112 7-111 0 0 1-6 DO 0 w QL` 6-10 2i 4-0 /D 1-6 Living / Dining Unit 2 SECOND LEVEL SPRINKLER LAYOUT SCALE: 14" = 1'-0" 4V. 112 6-1 4-7 edroom 55.5 psi 84.8 psi 29.3 psi Bedroom Bathroom SPRINKLER HEAD LOCATIONS HAVE NOT BEEN COORDINATED WITH CEILING -MOUNTED FIXTURES. INSTALLING SPRINKLER CONTRACTOR SHALL COORDINATE WITH ELECTRICIAN AND LOCATE SPRINKLERS AT LEAST 36" FROM THE CENTER OF ANY CEILING -MOUNTED FIXTURE, IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13R WHILE MAINTAINING THE MAXIMUM DISTANCES FROM WALLS INDICATED ON THIS DESIGN. ADDITIONAL SPRINKLERS REQUIRED DUE TO INABILITY TO MEET OBSTRUCTION CRITERIA SHALL BE AT THE OWNERS EXPENSE. 1 1 1 Caution: Care should be taken to avoid compressing the insulation. This reduces its R value. To prevent potential freeze -ups of the sprinkler piping, the insulation should be installed tight against the joists. INSULATION PROTECTING SPRINKLER PIPING ON UPPER FLOOR DETAIL NOT TO SCALE PROVIDE QUICK -RESPONSE RESIDENTIAL PENDENT SPRINKLERS IN ALL LOCATIONS INDICATED (TYPICAL, K=4.9, MAXIMUM SPACING: 181x18' MIN REQ: 18 GPM @ 13.5 PSI) main elec service 1 1 01 8-0 1-612 6-5'2 N <MC> 3-0 storage unit 1 storage unit 2 storage unit 3 storage unit 4 L 0 BASEMENT LEVEL SPRINKLER LAYOUT SCALE: %4" = 1'-0" 09 2 2 Basement 8-0 1-0 cv 0 1-0 2-4 2 LL1 cc LLI cc Design Area 1 THIRD FLOOR UNIT Demand Calculations using Hazen -Williams Method Occupancy Classification: RES 13R Design Area Density: 0.05 Additional Outside Hose: 100 Design Area Size: 326 Notes: THIS CALCULATION INCLUDES THE AREA PROTECTED BY THE HMD 4 RESIDENTIAL SPRINKLER HEADS ON THE THIRD FLOOR SPRINKLER CONTRACTOR SHALL TAKE PRECAUTIONS WHEN INSTALLING SPRINKLER PIPING IN JOISTS ON TOP FLOOR. GENERAL CONTRACTOR SHALL BE REQUIRED TO INSTALL SUFFICIENT INSULATION TO MAINTAIN 40-DEGREES IN ALL AREAS WHERE SPRINKLER PIPING AND HEADS ARE INSTALLED Wet System <004> 112 M Bathroom WITH BALL VALVES, 2-1/2" STRAIGHT -PIPE RISER WITH 1" COMBINATION TEST & DRAIN VALVE PIPED TO BUILDING EXTERIOR AND 21/2" FIRE DEPARTMENT CONNECTION FEED WITH CHECK VALVE AND BALL DRIP (SEE DETAIL, THIS SHEET) <158> 2" FIRE SERVICE FROM MUNICIPAL WATER MAIN (DESIGNED AND INSTALLED PER NFPA 24 BY OTHERS) PROVIDE 2162" SINGLE -INLET FIRE DEPARTMENT CONNECTION (TYPE AND FINAL LOCATION TO BE VERIFIED WITH SALEM FIRE DEPARTMENT PRIOR TO INSTALLATION) 1 12" RISER UP FROM GROUND LEVEL AND UP TO THIRD (VERIFY LOCATION IN -FIELD) M Bedroom Unit 4 <002> 2 112 Closet FREEZE PROTECTION THE BUILDING OWNER IS RESPONSIBLE FOR PROVIDING HEAT IN ALL AREAS CONTAINING SPRINKLER PIPING AND HEADS TO PREVENT PIPE FROM FREEZING. ANY AREAS THAT RAISE CONCERN WITH REGARD TO FREEZING POTENTIAL SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION, IN WRITING, PRIOR TO INSTALLATION. JFP SOLUTIONS, INC. AND THE ENGINEER OF RECORD TAKE NO RESPONSIBILITY FOR DAMAGES CAUSED BY FREEZE -UPS OF THE SPRINKLER SYSTEM. Bedroom Bathroom Kitchen 1-412 1-Stairs 0-11 674,1 7-1112 cv Living / Dining Unit 3 THIRD LEVEL SPRINKLER LAYOUT 1 12' RISERS UP FROM BASEMENT (VERIFY LOCATIONS IN -FIELD) ,170 4 Stairs Living / Dining Bedroom tairs 2-11 Unit 47_912 VW 1/2 Bath 0 0 Kitchen up CD Bathr 3-7 1 LCD Bedroom Bedroom M Bedroom 2-4 9-0 -112 Bedroom M Bathroom 5-8 8-5 0 0 7-8 CV 5-2 Kitchen 9-6 Stairs 6-4 7-8 Living / Dining Unit 1 GROUND LEVEL SPRINKLER LAYOUT DESIGNED 3Y: REVISIONS HEAD BLOCK 3FP SOLUTIONS, INC. FIRE PROTECTION CONSULTING SERVICES P.O. Box 1234 Lynnfield, Massachusetts 01940 Telephone: (781) 389-7999 DATE DESCRIPTION BY SYM CNT POSITION FINISH TEMP NPT MFG. MODEL# 0 57 RES PENDENT WHITE 155 4.90 1/2" GLOBE GL4906 1 1 RES SIDEWALL WHITE 155 4.40 1/2" GLOBE GL4431 UL LISTED CPVC SPRINKLER PIPING BLACK STEEL SPRINKLER PIPING SPRINKLER CONTRACTOR ETER NEW AUTO ATIC 13R SPRINKLER SYSTEM 107 BRI E TRE T SALEM, ASSACHUSETTS PROJECT ADDRESS SPRINKLER SYSTEM PERMIT SET PERMIT NO CONTRACT NO 4807 APPROVAL SALEM FD DRAWN BY T. JENKINS DATE 3/25/2019 REVISED FP 1 of 1 KAHAN FIRE PROTECTION PLOTTED