104 BRIDGE STREET - FPJob: RENOVATED RESIDENTIAL BUILDING Address: 104 BRIDGE STREET City: SALEM Contract #: 4659 Contractor: TO BE DETERMINED Address: City: State: MA Date: Designer: Zip/Postal Code: 01970 9/12/2017 JFP SOLUTIONS, INC. State: Zip/Postal Code: Phone: Fax: Email: Approving Authority: SALEM FD Design Defaults Default Sprig Size: Default Sprig Material: Default Sprig Elevation: 1 CPVC 0 Standards: NFPA 13R Default Drop Size: 1 Default Drop Material: CPVC Default Drop Elevation: 0 FIRE PROTECTION NARRATIVE / NOTES: MAX. HANGER SPACING PIPE TYPE NOMINAL PIPE SIZE (IN) s 1 174" 172" 2 272" 4 6 8 SCH 7,10,40 N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 SCH 30 LIGHT N/A 12-0 12-0 12-0 12-0 12-0 N/A N/A N/A - -36" MAX. FOR 1" DIA. 48" MAX. FOR 1 1/4" DIA. THEN -60" MAX. FOR 1 1/2" DIA. 0R LARGER EXTEND HERE 0 / 0/ 0/1 0/ 0 / a0/ 0/ DISTANCE BETWEEN OMIT HGR ON STARTER PIPES SHALL NOT EXCEED 6' OR LESS, No X-MAIN HGR ABOVE TABLE OMISSIONS ALLOWED IF GREATER THAN 36" MAX. FOR 1" DIA. IF GREATER THAN 48" MAX. FOR 1 1/4" DIA. IF GREATER THAN 60" FOR 1 1/2" DIA. OR LARGER - --.- THE PURPOSE OF THIS FIRE PROTECTION DRAWING AND THE ASSOCIATED HYDRAULIC CALCULATIONS IS TO INDICATE THE PROPOSED RESIDENTIAL SPRINKLER SYSTEM TO BE INSTALLED WITHIN THE RENOVATED MULTI -UNIT BUILDING LOCATED AT 104 BRIDGE STREET IN SALEM, MASSACHUSETTS. THIS EXISTING BUILDING IS COMPRISED OF A BASEMENT, FIRST FLOOR, SECOND FLOOR AND THIRD FLOOR AS INDICATED ON THE ARCHITECTURAL DRAWINGS. INTERIOR MODIFICATIONS TO THE LAYOUT WILL CONVERT THE BUILDING TO 4 RESIDENTIAL UNITS. THE BASEMENT WILL CONTAIN UTILITY AND STORAGE SPACE FOR THE BUILDING OCCUPANTS. THIS RESIDENTIAL SPRINKLER SYSTEM HAS BEEN DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13R (2013 EDITION) FOR A RESIDENTIAL BUILDING UP TO 4 STORIES IN HEIGHT AND NOT EXCEEDING 12,000 GROSS SF. THE SPRINKLER CONTRACTOR SHALL FOLLOW THE LATEST REQUIREMENTS OF NFPA 13 AND 13R (2013 EDITION), MASSACHUSETTS STATE BUILDING CODE AND SALEM FIRE DEPARTMENT REQUIREMENTS. THIS SYSTEM WILL BE SUPPLIED BY A NEW 2" COPPER SERVICE, TAPPED OFF THE EXISTING WATER MAIN ON SAUNDERS STREET. THE 2" SERVICE SHALL BE INSTALLED, FLUSHED AND TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 24 BY A LICENSED UNDERGROUND CONTRACTOR AND WILL ENTER THE BASEMENT AS INDICATED ON THIS DRAWING. THE SYSTEM HAS BEEN HYDRAULICALLY CALCULATED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13R, INCLUDING THE FOUR HYDRAULICALLY MOST DEMANDING HEADS IN A SINGLE COMPARTMENT BASED ON THE REQUIREMENTS OF THE SPECIFIC SPRINKLER HEAD AND THE SPACING USED IN THIS DESIGN (16'x16' REQUIRING A MINIMUM OF 16 GPM @ 13.2 PSI). THE BASEMENT HAS BEEN CALCULATED AS AN ORDINARY HAZARD GROUP I OCCUPANCY PER NFPA 13 REQUIREMENTS FOR AREAS OUTSIDE LIVING SPACES. REMOTE AREAS, DENSITIES AND HOSE STREAM ALLOWANCES ARE INDICATED ON THIS DRAWING. SYSTEM DEMANDS HAVE BEEN COMPARED TO HYDRANT FLOW DATA OBTAINED FROM THE WATER DEPARTMENT. COPIES OF THE CALCULATIONS HAVE BEEN SUBMITTED WITH THESE DRAWINGS TO THE SALEM FIRE AND BUILDING DEPARTMENTS FOR REVIEW. INSTALLATION NOTES: ALL WORK SHALL BE PERFORMED BY A MASSACHUSETTS LICENSED SPRINKLER CONTRACTOR. THE SPRINKLER CONTRACTOR SHALL FOLLOW THE LATEST REQUIREMENTS OF NFPA 13R (2013 EDITION), MASSACHUSETTS STATE BUILDING CODE (8TH EDITION) AND THE SALEM FIRE DEPARTMENTS. THE ARCHITECTURAL BACKGROUND OF BUILDING MAY DIFFER SLIGHTLY FROM ACTUAL LAYOUT. DRAWINGS ARE NOT INTENDED TO SHOW ALL OFFSETS AND PIPING ELEVATION CHANGES. CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS PRIOR TO FABRICATION. CONTRACTOR SHALL HYDROSTATICALLY TEST ALL SPRINKLER PIPING AT 200 PSI FOR 2 HOURS AND IS RESPONSIBLE FOR THE COMPLETION OF ALL ABOVE GROUND TEST CERTIFICATES, SUPPLIED TO THE OWNER. ALL PIPING INSTALLED ON THE FIRST, SECOND AND THIRD FLOORS SHALL BE UL LISTED CPVC SPRINKLER PIPING. ALL PIPING INSTALLED WITHIN THE BASEMENT UTILITY SPACE SHALL BE BLACK STEEL PIPING. ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13 (2013 EDITION) AND ALL MANUFACTURERS INSTALLATION RECOMMENDATIONS. ALL PIPING SHALL BE PITCHED TO DRAIN WITH LOW -POINT DRAINS AT SECTIONS OF PIPING SUBJECT TO WATER TRAPPING. SPRINKLER CONTRACTOR SHALL PROVIDE PROTECTIVE PLATES WHERE CPVC PIPING IS RUN THROUGH STUDS TO PREVENT PUNCTURING OF THE SPRINKLER PIPING DURING DRYWALL INSTALLATION AS REQUIRED BY NFPA STANDARDS. ALL SPRINKLER HEADS THROUGHOUT THE UPPER LEVELS WILL BE RESIDENTIAL PENDENT AND SIDEWALL HEADS. ALL SPRINKLER HEADS WITHIN THE BASEMENT LEVEL WILL BE QUICK -RESPONSE COMMERCIAL UPRIGHTS. ALL HEADS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS AND THE REQUIREMENTS OF NFPA 13 (2013 EDITION). THE BUILDING OWNER IS RESPONSIBLE FOR MAINTAINING THIS SPRINKLER SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 25, INCLUDING THE PROVISION OF HEAT IN ALL AREAS CONTAINING SPRINKLER PIPING AND HEADS TO PREVENT PIPE FROM FREEZING. ANY AREAS THAT RAISE CONCERN WITH REGARD TO FREEZING POTENTIAL DURING INSTALLATION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING PRIOR TO BEING INSTALLED. JFP SOLUTIONS, INC. AND JASON KAHAN TAKE NO RESPONSIBILITY FOR ANY DAMAGES CAUSED BY FREEZE UPS. Calculation results for Design Area 1 - THIRD FLOOR UNIT This system as shown on TO BE DETERMINED company print no dated 9/12/201 for RENOVATED RESIDENTIAL BUILDING at 104 BRIDGE STREET contract no 4659 is designed to discharge at a rate of 0.05 a maximum area of 434 ft2 when supplied with water at a rate of 65 gpm Hose stream allowance of is included in the above. Occupancy classification: RES 13R Commodity classification: Maximum storage height: Storage arrangement: gpm/ft2 (L/min/m2) of floor area over at 65 psi at the base of the riser. Number of heads flowing: 4 System Type: Wet Maximum velocity: 13.95 ft/s Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: 0 gpm 65 gpm 0 gpm 0 gpm 0 gpm 65 gpm 100 gpm 165 gpm Pressure Required at Source: Pressure Available at Source: Surplus Pressure at Source: Calculation results for Design Area 2 - BASEMENT 65 psi 84.8 psi 19.8 psi This system as shown on TO BE DETERMINED company print no dated 9/12/201 for RENOVATED RESIDENTIAL BUILDING at 104 BRIDGE STREET contract no 4659 is designed to discharge at a rate of 0.15 gpm/ft2 (L/min/m2) of floor area over a maximum area of 964 ft2 when supplied with water at a rate of 254.8 gpm at 67.7 psi at the base of the riser. Hose stream allowance of is included in the above. Occupancy classification: ORD HAZ I Commodity classification: Maximum storage height: Storage arrangement: Number of heads flowing: 13 System Type: Wet Maximum velocity: 27.13 ft/s Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: 0 gpm 254.8 gpm 0 gpm 0 gpm 0 gpm 254.8 gpm 250 gpm 504.8 gpm Pressure Required at Source: Pressure Available at Source: Surplus Pressure at Source: 2" x 2'-0 GALVI (THD BY THD) THROU7 WITH 45° EL AND WALL PLATE 272" GROOVED CHECK WITH BALL 2 72" SYSTEM FEED 272" STRAIGHT -PIPE RISER WITH FLOW PRESSURE GAUGE AND COMBINATION DRAIN 21/2' AMES C200 BACKFLOW PKEVENTER WITH MONITORED BUTTERFLY VALVES) 2"x 21/2" VIC-FLANGE 272" GROOVED TEE WITH CAP (FOR FORWARD FLOW TESTING OF BACKFLOW) 67.7 psi 83.4 psi 15.6 psi ELECTRIC BELL WITH BACKER -BOX (WIRED BY OTHERS) 21/2" x 2'-0 GALVI (THD BY GROOVE) THROUGH WALL SINGLE INLET 2-1/2" FIRE DEPARTMENT CONNECTION (COORDINATE WITH LOCAL FD PRIOR TO INSTALLATION) 2" DRAIN PIPED TO EXTERIOR PROPOSED 2" FIRE SERVICE (INSTALLED, FLUSHED, TESTED 4 CUT TO HEIGHT, BY OTHERS) RISER DETAIL SCALE: NOT TO SCALE Qi CLOSETS (TYPICAL) EXCEPT WHERE SPECIFIED IN SECTION 6.6.4 (NFPA 13R, 2013 EDITION), SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING CONDITIONS: 1) THE AREA OF THE SPACE DOES NOT EXCEED 24 SF 2) THE LEAST DIMENSION DOES NOT EXCEED 3 FT 3) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED IN NFPA 220. NOTE: WHEN MECHANICAL EQUIPMENT OR LAUNDRY MACHINES ARE PLACED IN THE CLOSET, THE CLOSET IS NO LONGER CONSIDERED A CLOTHES CLOSET, LINEN CLOSET, OR PANTRY, SO THE EXCEPTION OF 6.6.3 IS NO LONGER VALID AND SPRINKLERS MUST BE INSTALLED. Caution: Care should be taken to ovoid compressing the insulation. This reduces its R value. To prevent potential freeze -ups of the sprinkler piping, the insulation should be installed tight against the joists. INSULATION PROTECTING SPRINKLER PIPING ON UPPER FLOOR DETAIL NOT TO SCALE Design Area 2 BASEMENT M. Bedroom Wet System Demand Calculations using Hazen -Williams Method Occupancy Classification: ORD HAZ I Design Area Density: 0.15 Additional Outside Hose: 250 Design Area Size: 964 Notes: THIS CALCULATION INCLUDES THE HMD 964 SF OF UTILITY SPACE WITHIN THE BASEMENT LEVEL SYSTEM ISOMETRIC SCALE: NOT TO SCALE N N ■ s a irs up r Bathroom Bedroom 1 0 QIG I I I I I I I I I I PROVIDE QUICK -RESPONSE RESIDENTIAL PENDENT SPRINKLERS IN ALL LOCATIONS INDICATED (TYPICAL, K=4.9, MAXIMUM SPACING: 18')(181 MIN REQ: 18 GPM @ 13.5 PSI) Kitchen Living / Dining room Unit 2 11v 4 5-312 7: 5?2' 1 4-312 M. Bedroom 5-812 PROVIDE QUICK -RESPONSE UPRIGHT SPRINKLERS THROUGHOUT BASEMENT STORAGE / UTILITY AREA. ALL PIPING WITHIN BASEMENT LEVEL TO BE BLACK STEEL. 7-11 1 -o 1.4 -0 Bedroom Dull lu 3-7 + d La 'd w stai rs up Kitchen + 1 4: 8 7 • 114" CPVC RISER UP FROM BASEMENT AND UP TO SECOND LEVEL (VERIFY LOCATION WITH GC. GC RESPONSIBLE FOR PROVIDING SUFFICIENT INSULATION AND HEAT TO PREVENT WATER -FILLED SPRINKLER PIPING FROM FREEZING) 12-6 Unit 1 Living / Dining room ////I V/// #512 FIRST LEVEL SPRINKLER LAYOUT SCALE: Y4" = 1'-0" 111111111111111111 Ce> 114 114 II e i 114 8-0 4-8 2-8 14 1 4 II I1111111111111111111111111111111111111111111111111111 <B9 > 114 1 <B5> <B10> st ai rs ICI nNu1 111111+1 1111111111 n1IN!Pn1IIN111114u1u1 9-91 2 8-0 ltu11u11HUHliu11l11111111l11l11111111l IlIu1111 IIIH,H1IIIIutu11IHHN11I1u1u11111u1Iu11uIu111111III,HI11uI1Hu11I11F 9-9, 2 <B12> < 103 1:4 4-8 I 1 I I 110 I I 114 11 830 4-8 • 11 II • IIn111u1uu11uN11u11Hu11n1HIHu11111+1111luluu1luN11u1.+111n1 IW11.111NNN1uIIHH11I11HIHIn1IIUIIIIIIlululu NNN11nFHH11I 2-8 4 I I KB13> 11 11 I I 12-2 14 2-8 12-2 Basement 4 II I 114 II 114 <B14> 11111111uu1NNu1u11Hu11111HIH1nl1lullnl1luluu1NNu11n IHun111HIH1nl1lullnl1luluu1NNulullHu11111HIH1n11+1 9-91 2 2 2 17-8 .a 8-0 4-8 II II 11 I N 2-8 12-2 I I I I I I I I 4 L1 I I I I I I I I -0 < 109> `\' 212 4-8 1' 108 N 3-6 5-412 212" AMES C200 BACKFLOW PREVENTER WITH BALL VALVES, 2-1/2" STRAIGHT -PIPE RISER WITH 1" COMBINATION TEST & DRAIN VALVE PIPED TO BUILDING EXTERIOR AND 212" FIRE DEPARTMENT CONNECTION FEED WITH CHECK VALVE AND BALL DRIP (SEE DETAIL, THIS SHEET) 2" FIRE SERVICE FROM MUNICIPAL WATER MAIN (DESIGNED AND INSTALLED PER NFPA 24 BY OTHERS) 4 2-8 II I I I I I I I I I I 12-2 entry sta below BASEMENT LEVEL SPRINKLER LAYOUT SCALE: Y411 = 11-0" PROVIDE 212" SINGLE -INLET FIRE DEPARTMENT CONNECTION (TYPE AND FINAL LOCATION TO BE VERIFIED WITH SALEM FIRE DEPARTMENT PRIOR TO INSTALLATION) SAUNDERS STREET Source Information Date of Flow Test / Info : 8/17/2014 Location of flow test data : 87 BRIDGE STREET Source of flow test data : VILLAGE FIRE PROTECTION Source Data Points Pressure Flow 85.00 0.00 75.00 1350.00 Pump Data Points Pressure Flow O rs NOTE: SPRINKLER CONTRACTOR IS RESPONSIBLE FOR SELECTING THE PROPER LENGTH DRY-SIDEWALL, BASED ON MANUFACTURER'S RECOMMENDATIONS. GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTING SOFFIT AROUND DRY-SIDEWALL HEADS AFTER INSTALLATION. Bedroom ► Bathroom 1 v Master Bedroom Unit 4 3-5 T 6- stairs jIufl11nI.,'IIulj.luylull!11u1u1'III�1u"I"l'1= :° 4-8 Bedroom 6 \/ • • • 11 1111111 10-212 1 9-0 II I IIullulull Illullnul 11I11 1-3 9-412 < 020 > 1 v 1 d - room • 2 7z 2-9�ti Ili111I 111111IIj11[I 14111114114Iu,11411 IIu14III IN I111 11 I 14I I I I I I 1 1 I Illl 11111111111111411111I 1 I I111-11 I I 11116111NI I Iu 11IIII 11I 11 IIu1I 1I If L�• 11111111111111 II Bathroom 11111111111 1111111111111 11r • • • 1111111111111 • 2I A stairs< 1 2-11 <024> 7-1 • • Bathroo 4111•11111111111111111111111111111111u 1111111111111111111111111 Unit 3 Master Bedroom V / A 3-312 111. • • • • • • • • • • • • • • 11 I11/1.4111111.4111111.4WY11.11111111111.11411111.111111111111 I1II1II1II1II1II1II1II1II1II1II1 111111111 11111111111111111111111111111 111111111111111111111r THIRD LEVEL SPRINKLER LAYOUT SCALE: Y4" = 11-0" Bedroom w/d 11 3- o 4 1012 stairs Kitchen rt b 4-0 tic II I I I I Dining room I I I I I I I I I I I I I I Ir I I I I I I I I I I I I I I 11 Living room Unit 4 (058 Up 7-0 2 stair B ro 16-8 Bedroom 2-3 1-412 stai rs 112 Kitchen 6-1 3-11 Unit 3 Dining room REDUCER CUP DEFLECTOR DROP PIN ;UPPCRT SHELL CEILING 14-0 Living room 3-312 RUN CPVC PIPING EXPOSED BELOW CEILING (GC MAY BOX -IN IF DESIRED PROVIDED THAT SOFFITS ARE LESS THAN 8" DEEP) PROVIDE RESIDENTIAL SIDEWALL SPRINKLERS AS INDICATED (GLOBE MODEL GL4431, K=4.4, MINIMUM REQUIREMENTS 16 GPM @ 13.2 PSI FOR A MAXIMUM SPACING OF 16'x16I) 114" CPVC RISER UP FROM SECOND LEVEL (VERIFY LOCATION IN -FIELD WITH GENERAL CONTRACTOR) Design Area 1 Wet System THIRD FLOOR UNIT Demand Calculations using Hazen -Williams Method Occupancy Classification: RES 13R Design Area Density: 0.05 Additional Outside Hose: 100 Design Area Size: 434 Notes: THIS CALCULATION INCLUDES THE AREA PROTECTED BY THE HMD 4 RESIDENTIAL SPRINKLER HEADS ON THE THIRD FLOOR SECOND LEVEL SPRINKLER LAYOUT HOLE IN CEILING 3 5/16- -r " ADJUSTMENT FLAT PLATE CONCEALED PENDENT DIA HOLE IN WALL 29/32" / DIA '1,7/ 1" X 1/2' j REDUCER 11A" CPVC RISER UP TO THIRD FLOOR LEVEL 114" CPVC RISER UP FROM FIRST FLOOR LEVEL (VERIFY LOCATION WITH GC) P/-CUP WALL RETAINER 1" MIN. 1/2" OR 3/4" ADJUSTMENT RECESSED HORIZONTAL SIDEWALL DESIGNE BY: REVISIONS HEAD BLOCK 3FP SOLUTIONS, INC. FIRE PROTECTION CONSULTING SERVICES P.O. Box 1234 Lynnfield, Massachusetts 01940 Telephone: (781) 389-7999 DATE DESCRIPTION BY SYM CNT POSITION FINISH TEMP K NPT MFG. MODEL# 1 34 RES. SIDEWALL WHITE 155 4.40 1/2" GLOBE GL4431 -0. 15 RES. PENDENT WHITE 155 4.90 1/2" GLOBE GL4906 STEEL SPRINKLER PIPING CPVC SPRINKLER PIPING - - BE SPRINKLER CONTRACTOR T R E NEW AUT MATIC 13R SPRINKLER SYSTEM PROJECT ADDRESS 4 BRI TR T SALEM, MASSACHUSETTS PERMIT SET PERMIT NO CONTRACT NO 4659 APPROVAL SALEM FD DRAWN BY T. JENKINS SCALE DATE REVISED FP 1 of 1 JASON M.O. t KAHAN rn FIRE PROTECTION -4-1 s4T8::\ SiONAL PLOTTED