090519 Lynco Wherry Wharf LFP001 30X42-signed-1WHARF ST. 1 \ C4C 4 C5 O Al C 1� C2) 4" STANDPIPE 2-1/2" FIRE VALVE, 2-1/2" X 2-1/2" ADAPTER W/ CAP AND CHAIN, 2" DRAIN 1-1/2" FCVA N N 00 C 0- E 0) In 3 0 0' 0) 2 Z w J LL rn 1-76 rn lii 0 H O J 0_ WHARF ST. 8:12 FIRST FLOOR PLAN SCALE: 1/8" = 1'- 0" ROOF BELOW 0 NI \} BU2-71h 0'-101,, ROOF BELOW CLOSET 1 FOURTH FLOOR PLAN SCALE: 1/8" = 1'- 0" Bedroom Kitchen REF ROOFBELOW ROOF BELOW 4" STANDPIPE 2-1/2" B FIRE VALVE, 2-1/2" X 2-1/2" ADAPTER W/ CAP AND CHAIN, 2" DRAIN 1-1/2" FCVA _ 30L 1 11/2 `i) 1' ( r LI ruton 1,092 SF LYNCO ROOF BELOW OPEN TO BELOW Mach OPEN TO BELOW ROOF BELOW OPEN TOABOVE Living Room UNIT 301 O 1,066 SF • Living Room 2-0 FIRE PROTECTION INC. CONTRACTORS -ENGINEERS -INSTALLATIONS SALES -REPAIRS -INSPECTIONS PHONE - 781-221-0111 FAX - 781-229-8323 19 GRANT AVE BURLINGTON, MA OPEN TO ABOVE Cl MEMBRANE ROOF! G OVER TAPERED INSULATION 1 I 1 1'-111/ Bedroom • 3DS Bedroom 3'-10 Laundry Laundry ROOF BELOW 7:1 ROOF BELOW Bedroom �F 1 Bedroom Laundry W B..-4 • Bedroom ROOF BELOW Hydraulic Information Remote Area Corridor OCCUPANCY CLASSIFICATION Light Hazard DENSITY (gpm/ft2) 0.10 for 1500ft2 (Actual 303ft2) TOTAL HOSE STREAMS 100.00 TOTAL HEADS FLOWING 5 K-FACTOR 5.6 TOTAL WATER REQUIRED 219.99 TOTAL PRESSURE REQUIRED 67.496 BASE of RISER (gpm) 119.99 BASE of RISER (psi) 58.766 SAFETY MARGIN (psi) +28.107 (29.4%) Dining -3IXf UNIT 303 840 SF Kitchen Dining UN T 304 850 SF (D 1J 1 Living Room 1 2'-6 LMng Room ROOF ACCES Bedroom •c3 _Q 3U4 v • • 3-11 1'-101/2 E% UNIT 306 1,452 SF Living Room F1 UNIT 305 1,160 SF Living Room MEMBRANE ROOFIN OVER TAPERED INS °N OPEN TO BELOW F BELOW OPENTOABOVE Revisions ALUM. GUTTER W/DRAIN LEADER Hydraulic Information Remote Area 4th Floor 4 Most Remote OCCUPANCY CLASSIFICATION Residential DENSITY (gpm/ft2) 0.10 for 900ft2 (Actual 413ft2) TOTAL HOSE STREAMS 100.00 TOTAL HEADS FLOWING 4 K-FACTOR 4.9 TOTAL WATER REQUIRED 153.01 TOTAL PRESSURE REQUIRED 40.331 BASE of RISER (gpm) 53.01 BASE of RISER (psi) 31.735 SAFETY MARGIN (psi) +55.466 (57.9%) 15 5) 1" UP TO ATTIC (TYP.) (4 Dining Supply FlowTest Data Test Conducted By LYNCO FIRE PROTECTION Date of Test 9/4/19 Time of Test 10:00 pm Static Pressure 96.000 Residual Pressure: 85.000 Flow 1325.00 4" STANDPIPE 2-1/2" FIRE VALVE, 2-1/2" X 2-1/2" ADAPTER W/ CAP AND CHAIN, 2" DRAIN (1) CSC Sprinkler Legend Note Symbol Manufacturer SIN Model Quantity K-Factor Type Size Response Finish Temperature O Globe GL5606 GLSERIES 34 5.6 Pendent '16 Quick White 155°F CONCEALED Globe GL5615 GLSERIES 1 5.6 Upright 34 Quick Brass 155°F Globe GL5601 GLSERIES 9 5.6 Pendent 1% Quick White 200°F CONCEALED Globe GL4906 RESIDENTIAL 129 4.9 Pendent 1r6 Quick White 155°F 16x16 MAXIMUM Globe Sprinklers GL5641 GLSERIES 19 5.6 Sidewall '% Quick White 155°F DRYSIDEWALL 1�1 Globe GL5641 GL-DRY 17 5.6 Upright 1 Quick Bronze 200°F Total = 209 13)' 4" STANDPIPE 2-1/2" FIRE VALVE, 2-1/2" X 2-1 /2" ADAPTER W/ CAP AND CHAIN, 2" DRAIN 1-1/2" FCVA ROOF BELOW 5� (A) () 3) 4" STORZ FDC TYPE AND LOCATION TO BE COORDINATED AND APPROVED WITH THE FIRE DEPARTMENT SHUT-OFF FORC4) STANDPIPES (TYP. OF 2) EXISTING 4" DCVA BACKFLOW TO REMAIN RISER CHECK VALVE ASSEMBLY TO REPLACE THE EXISTING EXISTING DRAIN AND FDC LOCATION TO REMAIN UNLESS OTHERWISE NOTIFIED 4 BY FIRE DEPARTMENT OR AHJ EXISTING 4" UNDERGROUND Rev Date Description _AN - - Stair -TOT- Bedroom Stair 1'72-114 11/2- `_U 1/2 11 UNIT 202 798 SF SECOND FLOOR PLAN SCALE: 1/8" = 1'- 0" ROOF ABOVE UNIT 101 525 SF LEC. PANEL NEW PIPE FIRST FLOOR PLAN SCALE: 1/8" = 1'- 0" GENERAL NOTES: UNIT 201 866 SF Living Room Laundry Laundry 1 Living Room 2-9 2D, EXISTING TO REMAIN UNIT 102 1 2 1. THE SYSTEM AS SHOWN HAS BEEN DESIGNED AND SHALL BE INSTALLED BY LYNCO FIRE PROTECTION INC., LOCATED AT 19 GRANTAVENUE, BURLINGTON, MA. ANY USE OF THESE DRAWINGS FOR ANY OTHER USE IS STRICTLY PROHIBITED. 2. WHETHER OR NOT INDICATED IN THE DRAWINGS, THE FOLLOWING ITEMS SHALL BE PROVIDED: SPARE HEAD BOX, FLUSHING CONNECTIONS & INSPECTOR'S TEST VALVE. 3 ALL CONNECTIONS OF SPRINKLER DEVICES TO THE FIRE ALARM SYSTEM SHALL BE PERFORMED BY OTHERS. 4. OWNER IS RESPONSIBLE TO MAINTAIN THE SPRINKLER SYSTEM(S) IN ACCORDANCE WITH THE LATEST N.F.P.A. 25. "INSPECTION & MAINTENANCE OF WATER BASED FIRE PROTECTION SYSTEMS AND/ OR ALLAPPLICABLE FEDERAL STATE AND/ OR LOCAL LAWS, CODES AND ORDINANCES. 5.MASTATE FIRE SPRINKLER CONTRACTOR Paul Swanfeldt Lic#004508 723 SF EXIST. BATH Bedroom • HVAC EQUIP. v) CLOSET Bedroom Bath -2or • Bedroom ROOF BELOW cooc UNIT 103 852 SF FIRE PROTECTION NOTES: 1.SYSTEM DESIGN AND INSTALLATION TO CONFORM TO N.F.P.A. 13,14 AND THE MASSACHUSETTS STATE BUILDING CODE - 9TH EDITION 2.ALL MATERIAL, DESIGN AND WORKMANSHIP TO CONFORM TO N.F.P.A. 13, THE LOCAL FIRE DEPARTMENT AND ALL APPLICABLE CODES. 3.ALL NEW PIPING 1-1/4" AND SMALLER TO BE SCHEDULE 40 BLACK STEEL WITH CAST IRON SCREWED FITTINGS. ALL NEW PIPING 1-1/2"AND LARGER TO BE SCHEDULE 10 BLACK STEEL WITH GROOVED COUPLINGS, FITTINGS, MECHANICAL TEES AND WELDED OUTLETS. 4. RESIDENTIAL AREAS: BLAZEMASTER SHALL MEET THE REQUIREMENTS OF THE INSTALLATION GUIDE. IT IS THE CONTRACTORS RESPONSIBILTYTO VERIFY CONSTRUCTION TYPE, HEIGHTS AND ALL OTHER FACTORS ASSOCIATED WITH THE INSTALLATION GUIDE. ALL CONCEALED PIPING TO BE BLAZEMASTER CPVC WITH CPVC GLUED FITTINGS. 5.ALL SPRINKLER HEADS SHALL BE QUICK RESPONSE AND RESIDENTIAL TYPE. SEE SPRINKLER LEGEND FOR TYPE AND QUANTITIES. 6.FIRE STOP PROVIDEDATALL PIPING PENETRATIONS THROUGH RATED WALLS. 7.ALL PIPES SHALL BE SUPPORTED PER N.F.P.A. 13, 2013 EDITION AND MANUFACTURERS INSTALLATION REQUIREMENTS. 8.ALL EQUIPMENTAND DEVICES TO BE U.L. LISTED AND/ OR F.M. APPROVED. 9ALL CONNECTIONS OF SPRINKLER DEVICES TO THE FIRE ALARM SYSTEM SHALL BE PERFORMED BY OTHERS. 10. ALL ELECTRICAL WIRING OF THE SPRINKLER DEVICES SHALL BE DONE BYA LICENSED ELECTRICIAN. 11. HEATTO BE PROVIDED BYTHE OWNER AT 40 DEG. F MINIMUM IN ALL AREAS WITH SPRINKLER HEADS OR PIPING. 12. PER NFPA13 8.3.2.5 - SPRINKLERS LOCATED WITHIN 12" OF HEAT SOURCES SHALL REQUIRE INTERMEDIATE TEMPERATURE SPRINKLER HEADS. - ROOF BELOW N.I.C. E ST. BATH C1 2'-3 THIS DRAWING IS PREPARED BY LYNCO FIRE PROTECTION FOR USE IN CONNECTION WITH THIS PROJECT FOR USE SOLELY WITH RESPECT TO LYNCO FIRE PROTECTION WORK ON SUCH PROJECT. LYNCO FIRE PROTECTION RETAINS ALL COMMON LAW, STATUTORYAND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT, THE DRAWING SHALL NOT BE USED BY OTHERS ON OTHER PROJECTS OR FOR PERFORMANCE, COMPLETION, OR ADDITION TO THIS PROJECT BY OTHERS EXCEPT BYAGREEMENT OF LYNCO FIRE PROTECTION IN WRITING AND WITH APPROPRIATE COMPENSATION TO LYNCO FIRE PROTECTION. 5'-91h Living Room Stamp: ELEC. ROOM UNIT 204 1,095 SF CF � 0 Bedroom r TDT' 0 Bedroom 104 3 ?. ROOF BELOW FIRE SPRINKLER NARRATIVE THE PURPOSE OF THIS NARRATIVE IS TO DESCRIBE THE WET FIRE PROTECTION SPRINKLER SYSTEM AT 75 WHARF ST. IN SALEM, MA. THIS IS AN RECONSTRUCTION OF AN EXISTING BUILDING. MAJORITY OF THE 1ST FLOOR RETAIL IS GOING TO REMAIN AND RESIDENTIAL UNITS WILL BE ADDEDA RESIDENTIAL UNIT TO THE 1ST FLOOR, THE 2ND, 3RD AND 4TH FLOORS WILL BE RESIDENTIAL OCCUPANCY. THE ENTIRE BUILDING IS A WET SYSTEM WITH TWO STANDPIPES AND FLOOR CONTROL VALVES FOR EACH FLOOR. THE PROPOSED NEW SPRINKLER SYSTEM SHALL BE CONNECTED TO THE EXISTING 4" SERVICE AND 4" DCVA BACKFLOW WHICH IS TO REMAIN. THE SCOPE OF WORK CONSIST OF AN AUTOMATIC WET SPRINKLER SYSTEM THAT IS FED FROM THE EXISTING RISER ASSEMBLY LOCATED ON THE 1ST FLOOR IN THE SPRINKLER ROOM. THERE ARE TWO STANDPIPES THATARE CONNECTED ON THIS FLOOR, ONE STANDPIPE HAS FLOOR CONTROL VALVES FOR EACH FLOOR. THE SYSTEM SHALL BE DESIGNED AND HYDRAULICALLY CALCULATED ON THE THIRD FLOOR FOR RESIDENTIAL HAZARD OCCUPANCY AND SHALL PROVIDER A .10 DESIGN DENSITY FOR FOUR REMOTE HEADS WITH AN OUTSIDE HOSE OF 100 GPM. THE 3RD FLOOR CORRIDOR SHALL BE CALCULATED FOR LIGHT HAZARD AND SHALL PROVIDE A .10 DENSITY FOR FIVE HEADS WITH AN OUTSIDE HOSE OF 100 GPM. THE SYSTEM SHALL BE ACTIVATED WHEN A HEAT SOURCE WOULD FUSE A FIRE SPRINKLER HEAD, CAUSING THE HEAD TO OPEN AND FLOW WATER, WHICH SIMULTANEOUSLY TRIGGERS THE ALARM SYSTEM THAT WILL SIGNAL TO THE BOSTON FIRE DEPT. AND AN APPROVED CENTRAL LOCATION. THE BUILDING SHALL BE FITTED WITH AN AUTOMATIC FIRE ALARM SYSTEM (BY OTHERS) THAT SHALL PROVIDE AN AUDIBLE ALARM UPON ACTIVATION OF A FIRE SPRINKLER HEAD AND/OR TEST VALVE. THIS DRAWING IS INTENDED TO SHOW GENERAL ARRANGEMENT AND SCOPE OF WORK TO BE PERFORMED. ALL LOCATIONS ARE APPROXIMATE AND ARE SUBJECT TO CHANGE TO CONFORM TO STRUCTURAL AND/OR JOB CONDITIONS. PER NFPA 13 SECTION 8.17.4.6.1 MEANS SHALL BE PROVIDED DOWNSTREAM OF ALL BACKFLOW PREVENTION VALVES FOR TEST AT SYSTEM DEMAND F DRAIN 12" MIN FP SERVICE LINE BACKFLOW 36"-48" A. F. F. CHECK VALVE BALL DRIP BACKFLOW BUTTERFLY VALVE W/ TAMPER SWITCH (TYP.) UNI FLANGE SHALL BE MIN 12" ABOVE FINISH FLOOR TO WET SYSTEM FLOW SWITCH -111 RISER CHECK VALVE BUTTERFLY VALVE 18" MIN. U 12�� MIN. SO BOLT HOLES m TO WALLS (TYP.) \O SIDE WALL UNI FLANGE Side Beam Lag rT Bracket Nut & Wash. A.T.Rod Hanger Ring Steel G eB am -Clamp A.T.Rod - Hanger Ring NOTE: SURGE CLIPS TO BE PROVIDED AT END OF ALL BRANCH LINES HANGER ROD DROP -IN ANCHOR LOCKING NUT SUPPORT NUT BAND HANGER Hanger Ring HANGER ROD SPACING PIPE SIZE MAX. ALLOWABLE SPACING 1" r 11/4" 8' 11/2" 9' z" 10' 2 12" 11' 12' FROM STRUCTURE ADJUSTABLE SWIVEL RING UUFM HANGER ASSEMBLY EXTEND HANGER ROD TIGHTTO PIPE ALTERNATE: USE UL/FM SURGE SUPPRESSOR CLIPS TYPICAL END -OF -LINE BRANCH N.T.S. RISER DETAIL N.T.S. GENERAL HANGER DETAILS 4 4" STANDPIPE 2-1/2" FIRE VALVE, 2-1/2" X 2-1/2" ADAPTER W/ CAP AND CHAIN, 2" DRAIN ROOF BELOW CONNECT TO EXISTING (TYP.) N.T.S. T DROP NIPPLE FIELD SET 1"x12" REDUCER CEILING BRANCH LINE CONCEALED PENDENT SPRINKLER RATED AT 155°, U.O.N. SPRINKLER ARM -OVER DETAIL DRAIN ELBOW FOR BALL DRIP T VALVE / HORIZONTAL MOUNTED BALL DRIP VALVE PIPE TO OUTSIDE N T.S. FLOOR WALL WALL PLATE (TYPICAL) FIRE DEPARTMENT CONNECTION TYPE, FINISH & LOCATION TO BE COORDINATED WITH FIRE DEPT., OWNER & ARCHITECT -18" TO 48" EXISTING GRADE TYPICAL FIRE DEPT. CONNECTION DETAIL 8.0. FLOOR STRUCTURE B.0. EXIST. STEEL BEAM .D� EXIS . FLOOR INDICATING TYPE FLOOR CONTROL VALVE WITH SUPERVISORY SWITCH -WIRING BY OTHERS PRESSURE GAUGE T WATERFLOW SWITCH / WIRING BY OTHERS FEED MAIN lid 1‘. CHECK VAL SIGHT GLASS\ ] I \ 1II TEST VALVE TO DRAIN N.T.S. 2 SECTIONAL DRAIN VALVE UNION WITH CORROSION RESISTANT ORIFICE GIVING FLOW EQUIVALENT TO THE SMALLEST SPRINKLER ORIFICE IN THE SYSYTEM (FCVA) FLOOR CONTROL VALVE ASSEMBLY I EXISTING PIPE CPVC SCHEDULE 10/40 STEEL UNDERGROUND Water Information Static: Residual: Flow: Date: Location: Information By: Date: Designed by: 95 psi 85 psi 1325 gpm 9/4/19 22 DERBY St. Lynco Fire Protection Designer 9/5/19 B.G. Job Name: Contractor: WHERRY ROW APARTMENTS PICKERING WHARF BUILDING D SALEM, MA. 01970 M/R ROCKETT MANAGEMENT 57 WHARF ST., SUITE 2E SALEM, MA. 01970 Dwg Name: FIRE PROTECTION PARKING LEVEL FIRST FLOOR PLAN DETAILS AND NOTES Dwg No: Sheet: of