65 federal St FP 5.22.20
SL 48x48 SLIDER EERW BATH 48x4 LIVING ROOM 1"UP OPEN U \ IT # 2 RAILING (Low) 1 STEPv UP r UP 16 MECH EXISTG CHIMNEY BEDROOM CLG HT ® 7'0" ROOM AREA=180 SF 4) V_ SHWR g- 0 1 "UP 1 1/2" EXPRESS FEED UP TO SPR. RM. 1 1/4" SPR. PIPE DOWN / FROM SPR. RM. X4-7>1 1/4"v1 1/4" BATH STACKED FRLD STN w/VENT O J D '�W 1 1/2 CPVC EXPRESS FEED TO SPR. CLOSET ON 1ST FLOOR ELECTRIC BELL 1 1/2" FIRE DEPT. CONN. HYDRANT FLOW TEST DATA STATIC; 80 PSI RESIDUAL; 77 PSI FLOW;1190 GPM TEST CONDUCTED BY LYNCO FIRE PROT. AND SALEM WATER DEPT ON 08/12/19 @ 10 PM N fr— UP MECH 1 R 11/4"UP 48x48 SLI EERW BEDROOM CLG HT © 7'6" ROOM AREA=127 SF ,-2„ IJS 0 v LIVING ROOM CLG HT © 7'6" ROOM AREA=170 SF *4„ U\IT #3 +7,_2"(LOWER) fs 1/2 BAT, c0 BEDROOM CLG HT © 7'0" ROOM AREA=200 SF U\IT #1 +6-8" 1 1/2" CHECK VALVE 0 S x EERW Protection Pla= z — BASEMEN NEW 2" COPPER UNDGRD. DEDICATED FIRE SERVICE 3 41 CITY 8" UNDGRD WATER MAIN (CIRCULATING) FLDERAL ST. 1"X 1/2" TEST & DRAIN 1 1 /4" AMES BACKFLOW PREVENTOR MOD. 2000B-FP WITH BALL VALVES AND TAMPER SWITCI-ES 1 1/2" CPVC EXPRESS FROM THE FIRE SERVICE STUB „ 11 /4" 1 '44. crAwarrin ISM 1 1 /4" FLOW SWITCH WATTER PRESSURE GAUGE L.P. DRAIN 1ST. FL 1 1/4" CPVC TO SPRINKLERS AND 1 1 /2" FIRE DEPT. CONN. BASEMENT SPRINKLER ROOM DETAIL 1/4" = 1'-0" z 1 >-- LLJ 0 4 0 I� MO 0 II: 0 KITCHEN/DINE 247 SF u\iT #2° (uPPi.N WALKABLE GLASS PANELS 1/4" AAf v10D. 00C AND TA F-E BACKFLOW B-FF WITH B S NITCHE� EERW E NnnT��RrrY�� /4'"6UPPLY� M BELOW d OVERHANG ABOVE EXISTING PROPERTY LINE T"'"*1"---r 1 UPSDN 7 TH DN aR EXISTG CHIMNI L STEP UP 1"UP PREVENTOR ALL VALVES " UP&DN BEDROOM 157 SF *4„ 0 +7'-2" 1 1 / S UP TE P UP 1 " 5 0 1/4" 1 1/4" Fire DN 13R YER UP 1"UPS „ 1 BAT BEDROOM 145 SF 0 *4„ DN +7'-1"1/4"DN J ° KITCHEN/DINE <14>172 SF \ST #3 (UITER) 1 1/4" 0 UP 1 6R 1 KIT 0 UNIT #1 *4" New6"w.x6"h.soffit +7— a@ new sprinkler pipe LIVING/DINING ROOM 331 SF „ rotection Pla- I GENERAL NOTES 1ST hi' EN—RY PORCH — UP TO UNITS #4 & #5 DOR 3 —DENOTES HYDRAULIC REFERENCE POINT —DENOTES HYDRAULIC REFERENCE POINT OF FLOWING SPRINKLER *5" —DENOTES THE DISTANCE OF CENTER LINE OF PIPE BELOW THE DECK OR TOP OF STEEL +7'-2" —DENOTES THE DISTANCE OF CENTER LINE OF PIPE ABOVE FINISHED FLOOR IJS —DENOTES SPRINKLER PIPING INSTALLED IN JOIST SPACE (ALONG JOISTS) ABOVE DRYWALL CLNG. —DENOTES CEILING HEIGHT 1.THIS EXISTING BUILDING IS A FIVE UNIT, FOUR FLOORS HOUSE, CONSTRUCTED WITH COMBUSTIBLE MATERIALS THE SPRINKLER SYSTEM IS DESIGN PER NFPA 13R 13 STANDARDS AND PER NFPA 13 AS APPLICABLE. 2.ALL DESIGN AND INSTALLATION TO CONFORM TO NFPA 13, 13 & OTHER APPLICABLE NFPA STANDARDS AND STATE CODES 8TH EDITION. 3.ALL MATERIAL USED TO BE UL LISTED AND /OR F.M.APPROVED. 4.ALL EXPOSED 1" —2" PIPING IN THE BASEMENT MECH. RM. TO BE BLK. STEEL SCH.40 WITH TRD. ENDS & C.I.FITTINGS. 5.ALL 1"-2" PIPING IN RESIDENTIAL AREAS TO BE CPVC WITH CPVC PLAIN END FITTINGS LISTED FOR FIRE PROTECTION APPLICATION. 6.ALL CONTROL VALVES TO BE EQUIPPED WITH TAMPER SWITCHES NOTE #1: ALL LINEN CLOSETS CMALLER THAN 24 SQ.FT. AND BATHROOMS SMALLER THAN 55 SQ.F.T. ARE NOT REQUIRED TO BE PROTECTED BY SPRINKLERS PER NFPA 13R STANDARDS, SECT. 6.6 NOTE #2: SPRINKLER SPRAY PATTERN SHADOW ARE IS PERMITTED UP TO 15 SQ.FT. PER SPRINKLER AS ALLOWED PE NFPA 13R STANDARDS, SECT. 6.4.6.3.3.1 JASON CATALFO KAHAN FIRE PROTECTION NO. 483 TS 05/22/2020 0 1' 2' 3' 4' 5' 6' 7' B' 2 0 z P. E. STAMP OWNERS/BUILDING MANAGERS RESPONSIBILITIES 1. OWNER RESPONSIBLE TO MAINTAIN THE FIRE SUPPRESSION SYSTEM IN OPERATIONAL CONDITION 2. OWNER RESPONSIBLE TO SCHEDULE ALL NECESSARY SPRINKLER INSPECTIONS AS APPLICABLE, PER NFPA STANDARDS, WITH LICENSED SPRINKLER CO. 3. OWNER RESPONSIBLE TO PROVIDE HEAT AND MAINTAIN TEMPERATURE AT MIN. 40 IN ALL WET SPRINKLER PIPE LOCATIONS, TO PREVENT THE PIPE AND SPRINKLERS FROM FREEZING.. MA Lic. No. SC 142792 REVISIONS: NONE U) Q W SPRINKLER N N O \ N 0 z Lu Lu Lu W E-1 Ln 10 0) L.� Ln LL LC) L(-) N LL Ln Ln N U/ L- 0 0 N Ln 10 LC) Total This Sheet: F-T-1 0 N N U) O 1 0 0 z I —I cr 0 J 0 J 0 1 N J LC) J Ln J z 0 z z uJ 0 z w J J 0 J J 0 CC 0 Q 0 0 0 CC 0 uJ w 0 uJ CC 0 U) 0 w 0 w 0 w CC 3- 0 0 CO 0 J W m 0 J U' L LI CO 0 J 0 Lil m 0 J uJ m 0 J z c 0 AR—DIABLO-1-20 O 0_ File: FEDERAL ST_SPR N 0 0 DRAWING TITLE: Fire Protection Plan — BASEMENT AND 1ST FLOOR 0 CD 0 z z SCALE: 1 /4"=1' 0 0 i LIVING ROOM 329 SF UNIT #4 (LOWER) Fi EXISTING PROPERTY LINE UP KITCHEN/DINE 172 SF I JS 1 " UPSDN zws P 1" EXISTG CHIMNI 1 " DOWN STACKED FRNT LD STND W/D w/VENT 1 KITCHEN/DINE 179 SF 1 # 1 (2\ LEVEL) MASTER BEDROOM 234 SF -e Protection Plan — 2ND LOOR u\iT #5 (LOWER) HYD. REMOTE AREA; "A" TREE REMOTE SPRINKLERS FLOWING, EACH DISCHARGING A MIN. OF 18 GPM AS PER NFPA 13 R AND SPRINKLER LISTING + 100GPM 0.H.A. SYST. DEMAND IS 56.79 GPM @ 55.02 PSI AT THE BASE OF THE RISER (REF. POINT #3) -2-4 GLASS POCKET DRS BEDROOM 4-1 157 SF CHANGE EXIST'G WINDOW FOR EERW HVAC CHANGE EXIST'G WINDOW FOR EERW GLASS1B'LK - 1 /2 WALL— EXIST'G CHIMNEY EXISTG CHIMNEY BEDROOM 115 SF HYD. REMOTE AREA; "B" TREE REMOTE SPRINKLERS FLOWING, EACH DISCHARGING A MIN. OF 14 GPM AS PER NFPA 13 R AND SPRINKLER LISTING + 1000PM 0.H.A. SYST. DEMAND IS 29.50 GPM @ 47.18 PSI AT THE BASE OF THE RISER (REF. POINT #3) BEDROOM 5-2 110 SF l UNIT 5 (UPPE BEDROOM 5-1 150 SF FIXED SKYI ;F IT #1 3D LEVEL) EXISTG CHIMN BEDROOM 1 —3 131 SF Fire-rotection Pla- EXISTING WINDOW TO REMAIN — 3RD FLOOR O�-*Z�-1 OF MgS+S10 Z JASON CATALFO LP m 0 KAHAN -4 0 FIRE PROTECTION m NO. 4838R 05/22/2020 FOR GENERAL NOTES SEE PLAN FP lof 2 0 1' 2' 3' 4' 5' 6' 7' B' 2 0 z P. E. STAMP OWNERS/BUILDING MANAGERS RESPONSIBILITIES 1. OWNER RESPONSIBLE TO MAINTAIN THE FIRE SUPPRESSION SYSTEM IN OPERATIONAL CONDITION 2. OWNER RESPONSIBLE TO SCHEDULE ALL NECESSARY SPRINKLER INSPECTIONS AS APPLICABLE, PER NFPA STANDARDS, WITH LICENSED SPRINKLER CO. 3. OWNER RESPONSIBLE TO PROVIDE HEAT AND MAINTAIN TEMPERATURE AT MIN. 40 IN ALL WET SPRINKLER PIPE LOCATIONS, TO PREVENT THE PIPE AND SPRINKLERS FROM FREEZING.. MA Lic. No. SC 142792 REVISIONS: NONE SPRINKLER LS) 0 \ o 0 z W W W w W L.� Ln LC) C3) L.� Ln 0) LL Ln L(-) N LL La if") N Ct L- O 0 N Ln 10 Lf) Total This Sheet: 124 0 N U) 1 0 0 z I —I O J O J 1 N J if) J CD Ln 10 J Z W 0 Z W 0_ Z W 0 Z W 0_ J J 0 () J J W 0 L) >- CC 0 I-� Q 0 0 W U) (/) W U W (r 0 W C/) U) W U W (r 0 W Cr) (.n W U W 0 W (1) (/) W U W CC W O U w Qi W CO O J W CO O J W CO O J W CO O J W m O J Z c 0 AR—DIABLO-1-20 O 0_ File: FEDERAL ST_SPR N O N 0 0 DRAWING TITLE: Fire Protection Plan — 2ND AND 3RD FLOORS SALEM, MA PROTECTION, SCALE: 1 /4"=1'