Loading...
Dibiase Strongwater McIntireProject Name:Project Name: Strongwater Mcintire Address:Address: 18 Amanda Way, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: Whole House BOSTON, LOGAN IAP, MABOSTON, LOGAN IAP, MA Summer Outdoor F:8888 Summer Indoor F:7575 Design Grains:2828 Daily Range:MediumMedium Winter Outdoor F:1212 Winter Indoor F:7070 Cooling RH:50%50%Elevation (Ft):3030 LOAD CALCULATION TOTALSLOAD CALCULATION TOTALS Heating BTU:4151241512 Cooling BTU:2505625056 SHR:0.9100.910 CFM:11461146 Cooling Loads NameName AreaArea SensibleSensible LatentLatent AEDExcursion 0.00 844.29 0.00 aboveGradeWalls 1396.50 2732.25 0.00 belowGradeWalls 0.00 0.00 0.00 blowerMotor 0.00 0.00 0.00 ceilings 2272.10 3635.36 0.00 ducts 0.00 1121.29 524.44 floors 2272.10 646.87 0.00 infiltration 0.00 779.06 1037.30 internalLoads 0.00 3320.00 800.00 skylights 0.00 0.00 0.00 ventilation 0.00 0.00 0.00 windows 336.00 9615.07 0.00 winterHumidification 0.00 0.00 0.00 Totals -22694.19 2361.74 Heating Loads NameName AreaArea Heat LossHeat Loss AEDExcursion 0.00 0.00 aboveGradeWalls 1396.50 7370.73 belowGradeWalls 0.00 0.00 blowerMotor 0.00 0.00 ceilings 2272.10 4217.02 ducts 0.00 3414.56 floors 2272.10 2604.05 infiltration 0.00 6951.65 internalLoads 0.00 0.00 skylights 0.00 0.00 ventilation 0.00 0.00 windows 336.00 16954.56 winterHumidification 0.00 0.00 Totals -41512.57 AED Graph Approved ACCA MJ8 CalculationsApproved ACCA MJ8 Calculations Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed calculations are estimates on building use, weather data, and inputted values such a R-Values, window types, duct loss, etc. Equipment selections should meet both the latent and sensible gain as well as building heat loss. See Cool Calc Manual S Report for equipment sizing verification. Warning (1): This application has glass areas that produced relatively large cooling loads for part of the day. Zoning may be required to overcome spikes in solar load for one or more rooms. A zoned system may be required, or some rooms may require zone control (provided by individual, motorized, thermostatically controlled dampers). AEDExcursion 3.4% aboveGradeWalls 10.9% ceilings 14.5% ducts 6.6% floors 2.6% infiltration 7.2% internalLoads 16.4% windows 38.4% aboveGradeWalls 17.8% ceilings 10.2% ducts 8.2% floors 6.3%infiltration 16.7% windows 40.8% AED Graph HTM Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 19 200 4,000 8,000 12,000 16,000 HoursBTUH 1/3 Project Name:Project Name: Strongwater Mcintire Address:Address: 18 Amanda Way, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: Whole House COMPONENT LOADS Above Grade WallsAbove Grade Walls Construction Nr.Construction Nr.ExposureExposure AreaArea Heating HTMHeating HTM Cooling HTMCooling HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 12C-0s w NE 390.60 5.28 1.96 2061.59 764.21 0.00 12C-0s w SE 302.70 5.28 1.96 1597.65 592.23 0.00 12C-0s w SW 409.50 5.28 1.96 2161.34 801.19 0.00 12C-0s w NW 293.70 5.28 1.96 1550.15 574.62 0.00 Below Grade WallsBelow Grade Walls (none) Blower MotorBlower Motor (none) CeilingsCeilings Construction Nr.Construction Nr.AreaArea Heating HTMHeating HTM Cooling HTMCooling HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 16B-30 ad 2272.10 1.86 1.60 4217.02 3635.36 0.00 DuctsDucts EHLFEHLF ESGFESGF ELGELG Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 0.09 0.05 524.44 0.00 0.00 0.00 FloorsFloors Construction Nr.Construction Nr.AreaArea Heating HTMHeating HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 19C-11sp 2272.10 1.15 2604.05 646.87 0.00 InfiltrationInfiltration NCFM HeatingNCFM Heating NCFM CoolingNCFM Cooling Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 109.06 54.53 6951.65 779.06 1037.30 Internal LoadsInternal Loads Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 0.00 920.00 800.00 0.00 2400.00 0.00 VentilationVentilation (none) WindowsWindows Construction Nr.Construction Nr.ExposureExposure AreaArea Heating HTMHeating HTM Heating BTUHeating BTU Sensible BTU Avg.Sensible BTU Avg.Sensible BTU PeakSensible BTU Peak Latent BTULatent BTU 1G NE 6.00 50.46 302.76 119.82 204.06 0.00 1G NE 48.00 50.46 2422.08 966.34 1676.82 0.00 1G NE 36.00 50.46 1816.56 730.59 1290.85 0.00 1G SE 6.00 50.46 302.76 203.33 374.03 0.00 1G SE 36.00 50.46 1816.56 1232.49 2244.16 0.00 1G SE 36.00 50.46 1816.56 1245.01 2244.16 0.00 1G SW 6.00 50.46 302.76 210.90 386.39 0.00 1G SW 48.00 50.46 2422.08 1715.14 3171.11 0.00 1G SW 36.00 50.46 1816.56 1307.32 2438.35 0.00 1G NW 6.00 50.46 302.76 144.93 303.56 0.00 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 Winter HumidificationWinter Humidification (none) 2/3 Project Name:Project Name: Strongwater Mcintire Address:Address: 18 Amanda Way, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: Whole House ROOM LOADS Room NameRoom Name HeatingHeating SensibleSensible LatentLatent CoolingCooling CFMCFM Whole house 41512.57 19194.60 1037.30 20231.90 969.00 3/3