Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Dibiase Strongwater Hawthorne Manual J
Project Name:Project Name: Dibiase Strongwater Hawthorne Address:Address: 35 Osborne Hill Drive, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: both floors BOSTON, LOGAN IAP, MABOSTON, LOGAN IAP, MA Summer Outdoor F:8888 Summer Indoor F:7575 Design Grains:2828 Daily Range:MediumMedium Winter Outdoor F:1212 Winter Indoor F:7070 Cooling RH:50%50%Elevation (Ft):3030 LOAD CALCULATION TOTALSLOAD CALCULATION TOTALS Heating BTU:4628746287 Cooling BTU:2554725547 SHR:0.8900.890 CFM:11451145 Cooling Loads NameName AreaArea SensibleSensible LatentLatent AEDExcursion 0.00 183.07 0.00 aboveGradeWalls 2169.00 2157.07 0.00 belowGradeWalls 0.00 0.00 0.00 blowerMotor 0.00 0.00 0.00 ceilings 1146.50 1490.45 0.00 ducts 0.00 1166.04 488.11 floors 1146.50 491.16 0.00 infiltration 0.00 1031.93 1373.98 internalLoads 0.00 3550.00 1000.00 skylights 0.00 0.00 0.00 ventilation 0.00 0.00 0.00 windows 432.00 12615.24 0.00 winterHumidification 0.00 0.00 0.00 Totals -22684.96 2862.09 Heating Loads NameName AreaArea Heat LossHeat Loss AEDExcursion 0.00 0.00 aboveGradeWalls 2169.00 8177.13 belowGradeWalls 0.00 0.00 blowerMotor 0.00 0.00 ceilings 1146.50 1728.92 ducts 0.00 3633.15 floors 1146.50 1960.74 infiltration 0.00 8988.73 internalLoads 0.00 0.00 skylights 0.00 0.00 ventilation 0.00 0.00 windows 432.00 21798.72 winterHumidification 0.00 0.00 Totals -46287.39 AED Graph Approved ACCA MJ8 CalculationsApproved ACCA MJ8 Calculations Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed calculations are estimates on building use, weather data, and inputted values such a R-Values, window types, duct loss, etc. Equipment selections should meet both the latent and sensible gain as well as building heat loss. See Cool Calc Manual S Report for equipment sizing verification. Warning (1): This application has glass areas that produced relatively large cooling loads for part of the day. Zoning may be required to overcome spikes in solar load for one or more rooms. A zoned system may be required, or some rooms may require zone control (provided by individual, motorized, thermostatically controlled dampers). aboveGradeWalls 8.4% ceilings 5.8% ducts 6.5% floors 1.9% infiltration 9.4% internalLoads 17.8% windows 49.4% aboveGradeWalls 17.7% ceilings 3.7% ducts 7.8% floors 4.2% infiltration 19.4% windows 47.1% AED Graph HTM Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 19 200 5,000 10,000 15,000 20,000 HoursBTUH 1/4 Project Name:Project Name: Dibiase Strongwater Hawthorne Address:Address: 35 Osborne Hill Drive, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: both floors COMPONENT LOADS Above Grade WallsAbove Grade Walls Construction Nr.Construction Nr.ExposureExposure AreaArea Heating HTMHeating HTM Cooling HTMCooling HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 12F-0s w NE 175.20 3.77 0.99 660.50 174.24 0.00 12F-0s w SE 353.10 3.77 0.99 1331.19 351.16 0.00 12F-0s w SW 189.60 3.77 0.99 714.79 188.56 0.00 12F-0s w NW 366.60 3.77 0.99 1382.08 364.58 0.00 12F-0s w NE 175.20 3.77 0.99 660.50 174.24 0.00 12F-0s w SE 353.10 3.77 0.99 1331.19 351.16 0.00 12F-0s w SW 189.60 3.77 0.99 714.79 188.56 0.00 12F-0s w NW 366.60 3.77 0.99 1382.08 364.58 0.00 Below Grade WallsBelow Grade Walls (none) Blower MotorBlower Motor (none) CeilingsCeilings Construction Nr.Construction Nr.AreaArea Heating HTMHeating HTM Cooling HTMCooling HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 16B-38 ad 1146.50 1.51 1.30 1728.92 1490.45 0.00 DuctsDucts EHLFEHLF ESGFESGF ELGELG Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 0.09 0.05 488.11 0.00 0.00 0.00 FloorsFloors Construction Nr.Construction Nr.AreaArea Heating HTMHeating HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 19A-30p 1146.50 1.71 1960.74 491.16 0.00 InfiltrationInfiltration NCFM HeatingNCFM Heating NCFM CoolingNCFM Cooling Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 141.02 72.23 8988.73 1031.93 1373.98 Internal LoadsInternal Loads Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 0.00 1150.00 1000.00 0.00 2400.00 0.00 VentilationVentilation (none) WindowsWindows Construction Nr.Construction Nr.ExposureExposure AreaArea Heating HTMHeating HTM Heating BTUHeating BTU Sensible BTU Avg.Sensible BTU Avg.Sensible BTU PeakSensible BTU Peak Latent BTULatent BTU 1G NW 6.00 50.46 302.76 144.93 303.56 0.00 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 1G NE 6.00 50.46 302.76 123.71 226.22 0.00 1G NE 24.00 50.46 1211.04 494.85 904.88 0.00 1G SE 6.00 50.46 302.76 211.67 374.03 0.00 1G SE 36.00 50.46 1816.56 1270.04 2244.16 0.00 1G SE 36.00 50.46 1816.56 1270.04 2244.16 0.00 1G SW 6.00 50.46 302.76 224.88 426.40 0.00 1G SW 24.00 50.46 1211.04 899.51 1705.59 0.00 1G NW 6.00 50.46 302.76 144.93 303.56 0.00 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 1G NE 6.00 50.46 302.76 119.82 204.06 0.00 1G NE 24.00 50.46 1211.04 483.17 838.41 0.00 1G SE 6.00 50.46 302.76 203.33 374.03 0.00 1G SE 36.00 50.46 1816.56 1232.49 2244.16 0.00 1G SE 36.00 50.46 1816.56 1245.01 2244.16 0.00 2/4 1G SW 6.00 50.46 302.76 210.90 386.39 0.00 1G SW 24.00 50.46 1211.04 857.57 1585.55 0.00 Construction Nr.Construction Nr.ExposureExposure AreaArea Heating HTMHeating HTM Heating BTUHeating BTU Sensible BTU Avg.Sensible BTU Avg.Sensible BTU PeakSensible BTU Peak Latent BTULatent BTU Winter HumidificationWinter Humidification (none) 3/4 Project Name:Project Name: Dibiase Strongwater Hawthorne Address:Address: 35 Osborne Hill Drive, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: both floors ROOM LOADS Room NameRoom Name HeatingHeating SensibleSensible LatentLatent CoolingCooling CFMCFM first floor 23269.48 9004.15 686.99 9691.14 454.00 second floor 23017.91 9936.80 686.99 10623.79 501.00 4/4