Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
dibiase Strongwater Essex manual J
Project Name:Project Name: Dibiase Strongwater Essex Address:Address: 33 Osborne Hill Drive, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: one furnace 2 zones BOSTON, LOGAN IAP, MABOSTON, LOGAN IAP, MA Summer Outdoor F:8888 Summer Indoor F:7575 Design Grains:2828 Daily Range:MediumMedium Winter Outdoor F:1212 Winter Indoor F:7070 Cooling RH:50%50%Elevation (Ft):3030 LOAD CALCULATION TOTALSLOAD CALCULATION TOTALS Heating BTU:6070960709 Cooling BTU:2898728987 SHR:0.9100.910 CFM:13321332 Cooling Loads NameName AreaArea SensibleSensible LatentLatent AEDExcursion 0.00 0.00 0.00 aboveGradeWalls 2007.90 1996.86 0.00 belowGradeWalls 0.00 0.00 0.00 blowerMotor 0.00 0.00 0.00 ceilings 2208.00 2870.40 0.00 ducts 0.00 1369.58 472.51 floors 2208.00 3647.62 0.00 infiltration 0.00 993.67 1323.05 internalLoads 0.00 3320.00 800.00 skylights 0.00 0.00 0.00 ventilation 0.00 0.00 0.00 windows 432.00 12193.40 0.00 winterHumidification 0.00 0.00 0.00 Totals -26391.53 2595.56 Heating Loads NameName AreaArea Heat LossHeat Loss AEDExcursion 0.00 0.00 aboveGradeWalls 2007.90 7569.78 belowGradeWalls 0.00 0.00 blowerMotor 0.00 0.00 ceilings 2208.00 3329.66 ducts 0.00 4700.42 floors 2208.00 14655.60 infiltration 0.00 8655.52 internalLoads 0.00 0.00 skylights 0.00 0.00 ventilation 0.00 0.00 windows 432.00 21798.72 winterHumidification 0.00 0.00 Totals -60709.71 AED Graph Approved ACCA MJ8 CalculationsApproved ACCA MJ8 Calculations Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed calculations are estimates on building use, weather data, and inputted values such a R-Values, window types, duct loss, etc. Equipment selections should meet both the latent and sensible gain as well as building heat loss. See Cool Calc Manual S Report for equipment sizing verification. aboveGradeWalls 6.9% ceilings 9.9% ducts 6.4% floors 12.6% infiltration 8%internalLoads 14.2% windows 42.1% aboveGradeWalls 12.5% ceilings 5.5% ducts 7.7% floors 24.1%infiltration 14.3% windows 35.9% AED Graph HTM Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 19 200 5,000 10,000 15,000 20,000 HoursBTUH 1/4 Project Name:Project Name: Dibiase Strongwater Essex Address:Address: 33 Osborne Hill Drive, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: one furnace 2 zones COMPONENT LOADS Above Grade WallsAbove Grade Walls Construction Nr.Construction Nr.ExposureExposure AreaArea Heating HTMHeating HTM Cooling HTMCooling HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 12F-0s w NE 215.70 3.77 0.99 813.19 214.51 0.00 12F-0s w SE 280.20 3.77 0.99 1056.35 278.66 0.00 12F-0s w SW 219.30 3.77 0.99 826.76 218.09 0.00 12F-0s w NW 283.80 3.77 0.99 1069.93 282.24 0.00 12F-0s w N 300.00 3.77 0.99 1131.00 298.35 0.00 12F-0s w SE 215.70 3.77 0.99 813.19 214.51 0.00 12F-0s w S 280.20 3.77 0.99 1056.35 278.66 0.00 12F-0s w W 213.00 3.77 0.99 803.01 211.83 0.00 Below Grade WallsBelow Grade Walls (none) Blower MotorBlower Motor (none) CeilingsCeilings Construction Nr.Construction Nr.AreaArea Heating HTMHeating HTM Cooling HTMCooling HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 16B-38 ad 1098.20 1.51 1.30 1656.09 1427.66 0.00 16B-38 ad 1109.80 1.51 1.30 1673.58 1442.74 0.00 DuctsDucts EHLFEHLF ESGFESGF ELGELG Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 0.08 0.05 472.51 0.00 0.00 0.00 FloorsFloors Construction Nr.Construction Nr.AreaArea Heating HTMHeating HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 19A-0cp 1098.20 6.64 7289.30 1814.23 0.00 19A-0cp 1109.80 6.64 7366.30 1833.39 0.00 InfiltrationInfiltration NCFM HeatingNCFM Heating NCFM CoolingNCFM Cooling Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 135.79 69.55 8655.52 993.67 1323.05 Internal LoadsInternal Loads Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 0.00 920.00 800.00 0.00 2400.00 0.00 VentilationVentilation (none) WindowsWindows Construction Nr.Construction Nr.ExposureExposure AreaArea Heating HTMHeating HTM Heating BTUHeating BTU Sensible BTU Avg.Sensible BTU Avg.Sensible BTU PeakSensible BTU Peak Latent BTULatent BTU 1G NE 6.00 50.46 302.76 123.71 226.22 0.00 1G NE 24.00 50.46 1211.04 494.85 904.88 0.00 1G SE 6.00 50.46 302.76 211.67 374.03 0.00 1G SE 36.00 50.46 1816.56 1270.04 2244.16 0.00 1G SE 36.00 50.46 1816.56 1270.04 2244.16 0.00 1G SW 6.00 50.46 302.76 224.88 426.40 0.00 1G SW 24.00 50.46 1211.04 899.51 1705.59 0.00 1G NW 6.00 50.46 302.76 144.93 303.56 0.00 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 1G N 6.00 50.46 302.76 97.28 127.26 0.00 1G N 36.00 50.46 1816.56 583.69 763.55 0.00 1G N 36.00 50.46 1816.56 583.69 763.55 0.00 1G SE 6.00 50.46 302.76 203.33 374.03 0.00 1G SE 24.00 50.46 1211.04 821.66 1496.10 0.00 1G S 6.00 50.46 302.76 185.38 325.17 0.00 2/4 1G S 36.00 50.46 1816.56 1117.61 1951.02 0.00 1G S 36.00 50.46 1816.56 1122.97 1951.02 0.00 1G W 6.00 50.46 302.76 219.79 457.42 0.00 1G W 24.00 50.46 1211.04 879.17 1829.66 0.00 Construction Nr.Construction Nr.ExposureExposure AreaArea Heating HTMHeating HTM Heating BTUHeating BTU Sensible BTU Avg.Sensible BTU Avg.Sensible BTU PeakSensible BTU Peak Latent BTULatent BTU Winter HumidificationWinter Humidification (none) 3/4 Project Name:Project Name: Dibiase Strongwater Essex Address:Address: 33 Osborne Hill Drive, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: one furnace 2 zones ROOM LOADS Room NameRoom Name HeatingHeating SensibleSensible LatentLatent CoolingCooling CFMCFM first floor 30264.38 11794.16 658.84 12453.00 595.00 second floor 30445.32 11401.28 664.21 12065.49 575.00 4/4