Dibiase Strongwater Endicott Manual JProject Name:Project Name: Strongwater Endicott Address:Address: 35 Osborne Hill Drive, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: feeding 2 floors BOSTON, LOGAN IAP, MABOSTON, LOGAN IAP, MA Summer Outdoor F:8888 Summer Indoor F:7575 Design Grains:2828 Daily Range:MediumMedium Winter Outdoor F:1212 Winter Indoor F:7070 Cooling RH:50%50%Elevation (Ft):3030 LOAD CALCULATION TOTALSLOAD CALCULATION TOTALS Heating BTU:4772547725 Cooling BTU:2588825888 SHR:0.8800.880 CFM:11471147 Cooling Loads NameName AreaArea SensibleSensible LatentLatent AEDExcursion 0.00 183.07 0.00 aboveGradeWalls 2269.80 2257.32 0.00 belowGradeWalls 0.00 0.00 0.00 blowerMotor 0.00 0.00 0.00 ceilings 1256.30 1633.19 0.00 ducts 0.00 1360.77 859.82 floors 1256.30 222.11 0.00 infiltration 0.00 1130.75 1505.56 internalLoads 0.00 3320.00 800.00 skylights 0.00 0.00 0.00 ventilation 0.00 0.00 0.00 windows 432.00 12615.24 0.00 winterHumidification 0.00 0.00 0.00 Totals -22722.45 3165.38 Heating Loads NameName AreaArea Heat LossHeat Loss AEDExcursion 0.00 0.00 aboveGradeWalls 2269.80 8557.15 belowGradeWalls 0.00 0.00 blowerMotor 0.00 0.00 ceilings 1256.30 1894.50 ducts 0.00 4737.39 floors 1256.30 888.46 infiltration 0.00 9849.58 internalLoads 0.00 0.00 skylights 0.00 0.00 ventilation 0.00 0.00 windows 432.00 21798.72 winterHumidification 0.00 0.00 Totals -47725.79 AED Graph Approved ACCA MJ8 CalculationsApproved ACCA MJ8 Calculations Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed calculations are estimates on building use, weather data, and inputted values such a R-Values, window types, duct loss, etc. Equipment selections should meet both the latent and sensible gain as well as building heat loss. See Cool Calc Manual S Report for equipment sizing verification. Warning (1): This application has glass areas that produced relatively large cooling loads for part of the day. Zoning may be required to overcome spikes in solar load for one or more rooms. A zoned system may be required, or some rooms may require zone control (provided by individual, motorized, thermostatically controlled dampers). aboveGradeWalls 8.7% ceilings 6.3% ducts 8.6% floors 0.9% infiltration 10.2% internalLoads 15.9% windows 48.7% aboveGradeWalls 17.9% ceilings 4% ducts 9.9% floors 1.9% infiltration 20.6% windows 45.7% AED Graph HTM Average Average * 1.3 8 9 10 11 12 13 14 15 16 17 18 19 200 5,000 10,000 15,000 20,000 HoursBTUH 1/4 Project Name:Project Name: Strongwater Endicott Address:Address: 35 Osborne Hill Drive, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: feeding 2 floors COMPONENT LOADS Above Grade WallsAbove Grade Walls Construction Nr.Construction Nr.ExposureExposure AreaArea Heating HTMHeating HTM Cooling HTMCooling HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 12F-0s w NE 193.20 3.77 0.99 728.36 192.14 0.00 12F-0s w SE 359.40 3.77 0.99 1354.94 357.42 0.00 12F-0s w SW 203.10 3.77 0.99 765.69 201.98 0.00 12F-0s w NW 379.20 3.77 0.99 1429.58 377.11 0.00 12F-0s w NE 193.20 3.77 0.99 728.36 192.14 0.00 12F-0s w SE 359.40 3.77 0.99 1354.94 357.42 0.00 12F-0s w SW 203.10 3.77 0.99 765.69 201.98 0.00 12F-0s w NW 379.20 3.77 0.99 1429.58 377.11 0.00 Below Grade WallsBelow Grade Walls (none) Blower MotorBlower Motor (none) CeilingsCeilings Construction Nr.Construction Nr.AreaArea Heating HTMHeating HTM Cooling HTMCooling HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 16B-38 ad 1256.30 1.51 1.30 1894.50 1633.19 0.00 DuctsDucts EHLFEHLF ESGFESGF ELGELG Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 0.11 0.06 859.82 0.00 0.00 0.00 FloorsFloors Construction Nr.Construction Nr.AreaArea Heating HTMHeating HTM Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 19D-30sp 1256.30 0.71 888.46 222.11 0.00 InfiltrationInfiltration NCFM HeatingNCFM Heating NCFM CoolingNCFM Cooling Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 154.52 79.15 9849.58 1130.75 1505.56 Internal LoadsInternal Loads Heating BTUHeating BTU Sensible BTUSensible BTU Latent BTULatent BTU 0.00 920.00 800.00 0.00 2400.00 0.00 VentilationVentilation (none) WindowsWindows Construction Nr.Construction Nr.ExposureExposure AreaArea Heating HTMHeating HTM Heating BTUHeating BTU Sensible BTU Avg.Sensible BTU Avg.Sensible BTU PeakSensible BTU Peak Latent BTULatent BTU 1G NW 6.00 50.46 302.76 144.93 303.56 0.00 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 1G NE 6.00 50.46 302.76 119.82 204.06 0.00 1G NE 24.00 50.46 1211.04 483.17 838.41 0.00 1G SE 6.00 50.46 302.76 203.33 374.03 0.00 1G SE 36.00 50.46 1816.56 1232.49 2244.16 0.00 1G SE 36.00 50.46 1816.56 1245.01 2244.16 0.00 1G SW 6.00 50.46 302.76 210.90 386.39 0.00 1G SW 24.00 50.46 1211.04 857.57 1585.55 0.00 1G NE 6.00 50.46 302.76 123.71 226.22 0.00 1G NE 24.00 50.46 1211.04 494.85 904.88 0.00 1G SE 6.00 50.46 302.76 211.67 374.03 0.00 1G SE 36.00 50.46 1816.56 1270.04 2244.16 0.00 1G SE 36.00 50.46 1816.56 1270.04 2244.16 0.00 1G SW 6.00 50.46 302.76 224.88 426.40 0.00 1G SW 24.00 50.46 1211.04 899.51 1705.59 0.00 1G NW 6.00 50.46 302.76 144.93 303.56 0.00 2/4 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 1G NW 36.00 50.46 1816.56 869.60 1821.36 0.00 Construction Nr.Construction Nr.ExposureExposure AreaArea Heating HTMHeating HTM Heating BTUHeating BTU Sensible BTU Avg.Sensible BTU Avg.Sensible BTU PeakSensible BTU Peak Latent BTULatent BTU Winter HumidificationWinter Humidification (none) 3/4 Project Name:Project Name: Strongwater Endicott Address:Address: 35 Osborne Hill Drive, Salem, MA FormType: FormType: HVAC System HVAC System Name: HVAC System Name: feeding 2 floors ROOM LOADS Room NameRoom Name HeatingHeating SensibleSensible LatentLatent CoolingCooling CFMCFM first floor 23304.44 8782.39 752.78 9535.17 443.00 second floor 24421.35 10406.75 752.78 11159.53 525.00 4/4