Loading...
Parlee_2020_0109.sd sET01BASEMENT PLAN1/4" = 1'-0"MECHGARAGE12'-0" x 27''-0"STAIRCARPET301 HR FIRE RATEDDOORI HR RATED WALL TYP. FORGARAGE SEPARATION. TOINCLUDE BUT NOT LIMITEDTO WALL AND CEILINGSEPARATION.FAMILY ROOMUP16' X 7'CLSTDNFURNACEUP19192830ON A 4"SLABSLOPESTAIRHARDWOODUPDNGREAT RMHARDWOODKITCHENHARDWOODDININGHARDWOOD02FIRST FLOOR PLAN1/4" = 1'-0"PATIO11'-0" x 12'-0"CLST1/2BATH24in VanityUP2X6 WALL2X6 WALL242426302626UP35in RangeFOYERCENTERED ONGARAGE DOORBELOWGENERAL NOTES:1. G.C. IS RESPONSIBLE FOR COMPLETING ALL WORK ACCORDING TO ALL FEDERAL, STATE AND LOCAL REGULATIONS.2. G.C. IS RESPONSIBLE TO COORDINATE WITH ALL TRADES AND VERIFY ALL DIMENSIONS PRIOR TO INSTALLATION.3. ALL WINDOWS AND DOORS ARE TO BE COMPLIANT WITH THE MASS. ENERGY CODE4. ALL NEW WINDOWS AND DOORS SHALL BE PROPERLY FLASHED AND WEATHER TIGHT. REFER TO WINDOW AND DOOR SCHEDULE FOR MOREINFORMATION.5. ALL LOAD BEARING WALLS WITH OPENING SHALL BE REINFORCED APPROPRIATELY AND PER CODE.6. ALL FIRE RATED WALLS & FLOORS THAT REQUIRES FIRE SEPARATION SHALL BE PROTECTED ACCORDING TO FEDERAL & STATE CODE.7. ALL MATERIALS, FIXTURES, AND EQUIPMENT SHALL BE PROVIDED AS NEW AND IN AN "UNUSED" CONDITION UNLESS OTHERWISE STATED IN THE PERMITSET OR OWNER APPROVED.8. ALL DISCREPANCIES IN THE FIELD SHALL BE RECORDED AND GIVEN TO THE OWNER AT END OF CONTRACT.9. ANY AND ALL DESIGN DISCREPANCIES SHALL BE APPROVED BY OWNER.10. G.C. IS RESPONSIBLE TO SIZE ALL LUMBER PER CODE & PROVIDE ENGINEERING CERTS. AS NEEDEDA1.0PROPOSEDFLOOR PLANS1/4" = 1'-0"SHEET NO.:SCALE:ARCHITECT STAMP:DATE:JULY 3, 2019ISSUE:SCHEMATIC DESIGNPROJECT NO.:.10 Juniper RdSalem, NH 03079857.212.5228NO.REVISIONS:DATE12345678-CONSULTANT:PROPERTY OWNER:MIKE BECKER978-590-4181PROJECT ADDRESS:19 PARLEE STREETEXTENSIONSALEM, MAGENERAL CONTRACTOR:.910- NOT FOR CONSTRUCTION CLSTM. BEDROOMHARDWOODLAUNDRY RMBEDROOM #2HARDWOODBEDROOM #1HARDWOODBATHTILEM. BATHTILECLST60in VanityVIFSEAT01SECOND FLOOR PLAN1/4" = 1'-0"PORCH ROOFCLSTSTAIRHARDWOODUPDNLINEN2X6 WALL2X6 WALL2X6 WALL2828262613262413282020131313CLST 20 20 TUBOPTION B: W/D LOC.60in VanityVIFCENTEREDON TRIPLEBELOW5'-0" HEIGHT WALLBEDROOM #3CARPET02ATTIC PLAN1/4" = 1'-0"7STAIRHARDWOODDN5'-0" HEIGHT WALL36in VanityVIF0262828BATHTILEMECH/STORAGEUNFINISHEDSTORAGEUNFINISHED26LOFTCARPET282HALF WALL77GENERAL NOTES:1. G.C. IS RESPONSIBLE FOR COMPLETING ALL WORK ACCORDING TO ALL FEDERAL, STATE AND LOCAL REGULATIONS.2. G.C. IS RESPONSIBLE TO COORDINATE WITH ALL TRADES AND VERIFY ALL DIMENSIONS PRIOR TO INSTALLATION.3. ALL WINDOWS AND DOORS ARE TO BE COMPLIANT WITH THE MASS. ENERGY CODE4. ALL NEW WINDOWS AND DOORS SHALL BE PROPERLY FLASHED AND WEATHER TIGHT. REFER TO WINDOW AND DOOR SCHEDULE FOR MOREINFORMATION.5. ALL LOAD BEARING WALLS WITH OPENING SHALL BE REINFORCED APPROPRIATELY AND PER CODE.6. ALL FIRE RATED WALLS & FLOORS THAT REQUIRES FIRE SEPARATION SHALL BE PROTECTED ACCORDING TO FEDERAL & STATE CODE.7. ALL MATERIALS, FIXTURES, AND EQUIPMENT SHALL BE PROVIDED AS NEW AND IN AN "UNUSED" CONDITION UNLESS OTHERWISE STATED IN THE PERMITSET OR OWNER APPROVED.8. ALL DISCREPANCIES IN THE FIELD SHALL BE RECORDED AND GIVEN TO THE OWNER AT END OF CONTRACT.9. ANY AND ALL DESIGN DISCREPANCIES SHALL BE APPROVED BY OWNER.10. G.C. IS RESPONSIBLE TO SIZE ALL LUMBER PER CODE & PROVIDE ENGINEERING CERTS. AS NEEDEDA1.1PROPOSEDFLOOR PLANS1/4" = 1'-0"SHEET NO.:SCALE:ARCHITECT STAMP:DATE:JULY 3, 2019ISSUE:SCHEMATIC DESIGNPROJECT NO.:.10 Juniper RdSalem, NH 03079857.212.5228NO.REVISIONS:DATE12345678-CONSULTANT:PROPERTY OWNER:MIKE BECKER978-590-4181PROJECT ADDRESS:19 PARLEE STREETEXTENSIONSALEM, MAGENERAL CONTRACTOR:.910- NOT FOR CONSTRUCTION 02SIDE ELEVATION1/4" = 1'-0"1216ROOFEL + 41'- 10"FROM BASEMENT FLOORATTICEL + 27'- 0"SECOND FLOOREL + 18'- 4"FIRST FLOOREL + 8'- 8"EL + 0'- 0"BASEMENT1104SIDE ELEVATION1/4" = 1'-0"1111641413ROOFEL + 41'- 10"FROM BASEMENT FLOORATTICEL + 27'- 0"SECOND FLOOREL + 18'- 4"FIRST FLOOREL + 8'- 8"EL + 0'- 0"BASEMENTGENERAL NOTES:1. G.C. IS RESPONSIBLE FOR COMPLETING ALL WORK ACCORDING TO ALL FEDERAL, STATE AND LOCAL REGULATIONS.2. G.C. IS RESPONSIBLE TO COORDINATE WITH ALL TRADES AND VERIFY ALL DIMENSIONS PRIOR TO INSTALLATION.3. ALL WINDOWS AND DOORS ARE TO BE COMPLIANT WITH THE MASS. ENERGY CODE4. ALL NEW WINDOWS AND DOORS SHALL BE PROPERLY FLASHED AND WEATHER TIGHT. REFER TO WINDOW AND DOOR SCHEDULE FOR MOREINFORMATION.5. ALL LOAD BEARING WALLS WITH OPENING SHALL BE REINFORCED APPROPRIATELY AND PER CODE.6. ALL FIRE RATED WALLS & FLOORS THAT REQUIRES FIRE SEPARATION SHALL BE PROTECTED ACCORDING TO FEDERAL & STATE CODE.7. ALL MATERIALS, FIXTURES, AND EQUIPMENT SHALL BE PROVIDED AS NEW AND IN AN "UNUSED" CONDITION UNLESS OTHERWISE STATED IN THE PERMITSET OR OWNER APPROVED.8. ALL DISCREPANCIES IN THE FIELD SHALL BE RECORDED AND GIVEN TO THE OWNER AT END OF CONTRACT.9. ANY AND ALL DESIGN DISCREPANCIES SHALL BE APPROVED BY OWNER.10. G.C. IS RESPONSIBLE TO SIZE ALL LUMBER PER CODE & PROVIDE ENGINEERING CERTS. AS NEEDEDA2.1PROPOSEDELEVATIONS1/4" = 1'-0"SHEET NO.:SCALE:ARCHITECT STAMP:DATE:JULY 3, 2019ISSUE:SCHEMATIC DESIGNPROJECT NO.:.10 Juniper RdSalem, NH 03079857.212.5228NO.REVISIONS:DATE12345678-CONSULTANT:PROPERTY OWNER:MIKE BECKER978-590-4181PROJECT ADDRESS:19 PARLEE STREETEXTENSIONSALEM, MAGENERAL CONTRACTOR:.910- NOT FOR CONSTRUCTION EL + 0'- 0"ROOFFIRST FLOOREL + 8'- 8"BASEMENTSECOND FLOOREL + 18'- 4"ATTICEL + 27'- 0"EL + 41'- 10"FROM BASEMENT FLOOR01FRONT ELEVATION1/4" = 1'-0"111111EL + 0'- 0"ROOFFIRST FLOOREL + 8'- 8"BASEMENTSECOND FLOOREL + 18'- 4"ATTICEL + 27'- 0"EL + 41'- 10"FROM BASEMENT FLOOR03REAR ELEVATION1/4" = 1'-0"33GENERAL NOTES:1. G.C. IS RESPONSIBLE FOR COMPLETING ALL WORK ACCORDING TO ALL FEDERAL, STATE AND LOCAL REGULATIONS.2. G.C. IS RESPONSIBLE TO COORDINATE WITH ALL TRADES AND VERIFY ALL DIMENSIONS PRIOR TO INSTALLATION.3. ALL WINDOWS AND DOORS ARE TO BE COMPLIANT WITH THE MASS. ENERGY CODE4. ALL NEW WINDOWS AND DOORS SHALL BE PROPERLY FLASHED AND WEATHER TIGHT. REFER TO WINDOW AND DOOR SCHEDULE FOR MOREINFORMATION.5. ALL LOAD BEARING WALLS WITH OPENING SHALL BE REINFORCED APPROPRIATELY AND PER CODE.6. ALL FIRE RATED WALLS & FLOORS THAT REQUIRES FIRE SEPARATION SHALL BE PROTECTED ACCORDING TO FEDERAL & STATE CODE.7. ALL MATERIALS, FIXTURES, AND EQUIPMENT SHALL BE PROVIDED AS NEW AND IN AN "UNUSED" CONDITION UNLESS OTHERWISE STATED IN THE PERMITSET OR OWNER APPROVED.8. ALL DISCREPANCIES IN THE FIELD SHALL BE RECORDED AND GIVEN TO THE OWNER AT END OF CONTRACT.9. ANY AND ALL DESIGN DISCREPANCIES SHALL BE APPROVED BY OWNER.10. G.C. IS RESPONSIBLE TO SIZE ALL LUMBER PER CODE & PROVIDE ENGINEERING CERTS. AS NEEDEDA2.0PROPOSEDELEVATIONS1/4" = 1'-0"SHEET NO.:SCALE:ARCHITECT STAMP:DATE:JULY 3, 2019ISSUE:SCHEMATIC DESIGNPROJECT NO.:.10 Juniper RdSalem, NH 03079857.212.5228NO.REVISIONS:DATE12345678-CONSULTANT:PROPERTY OWNER:MIKE BECKER978-590-4181PROJECT ADDRESS:19 PARLEE STREETEXTENSIONSALEM, MAGENERAL CONTRACTOR:.910- NOT FOR CONSTRUCTION