7_Electrical
UNIT NUMBER v 131/ MW AL 1317 AL 0 AL 0 0 v 1107 v 0 v AL AL v DESCRIPTION VOLTS 102" 80" 54" MAX 48" 18" EE N— FIRE ALARM AUDIO/VISUAL DEVICE SWITCHES PROVIDE PENDANT WHERE HUNG CEILING OR STRUCTURE EXCEEDS 8'-6" AFF. EXIT SIGN WALL TELEPHONES FIRE ALARM PULL STATION CATV/TELEPHONE/ DATA OUTLETS RECEPTACLES ELECTRICAL - OUTLET 4_ IK//////////////// COUNTER rFINISHED FLOOR 44" MAX \\\ OUTLET ABOVE COUNTER NOTES: 1. ALL MOUNTING HEIGHTS SHALL BE MEASURED FROM FINISHED FLOOR TO CENTERLINE OF DEVICE EXCEPT EXIT SIGN. 2. DEVICES SHALL BE INSTALLED ON A COMMON VERTICAL CENTERLINE WHEREVER POSSIBLE. 3. ALL DEVICES SHALL BE INSTALLED AT MOUNTING HEIGHTS AS INDICATED ON THIS DETAIL UNLESS OTHERWISE NOTED. PH. CIRCUIT BREAKER ROOF TOP UNIT 208 3 DUCTLESS SPLIT SYSTEM OUTDOOR 208 1 INDOOR UNIT ELECTRIC UNIT HEATER 208 3 ELECTRIC UNIT HEATER 208 3 ELECTRIC UNIT HEATER 208 3 ELECTRIC UNIT HEATER 208 3 ELECTRIC UNIT HEATER 208 3 CABINET UNIT HEATER 208 1 CABINET UNIT HEATER 208 1 CABINET UNIT HEATER 208 1 CABINET UNIT HEATER 208 1 GARAGE EXHAUST FAN 208 3 GARAGE EXHAUST FAN 120 1 GARAGE EXHAUST FAN 120 1 EXHAUST FAN 120 1 DRYER EXHAUST FAN 120 1 TRASH EXHAUST FAN 120 1 OA FAN CONDOS 120 1 GAS WATER HEATER 120 1 GROUNDWATER PUMP 120 1 MECHANICAL EQUIPMENT GENERAL NOTES: ELECTRICAL DEVICE MOUNTING HEIGHTS DETAIL NOT TO SCALE MECHANICAL EQUIPMENT SCHEDULE WIRE AND CONDUIT PANEL 70/3P 3#3, 1 #6G., 1-1 /2"C. HPR 30/2P 2#10, 1#10G., 3/4"C. HPR 2#12, 1#12G., 3/4"C. 110/3P 3#3, 1 #8G., 1-1 /4"C. DP 90/3P 3#4, 1#8G., 1"C. GPB 90/3P 3#4, 1#8G., 1"C. 90/3P 3#4, 1#8G., 1"C. 60/3P 3#6, 1#10G., 3/4"C. 15/2P 2#12, 1 # 12G., 3/4"C. 25/2P 2#10, 1#10G., 3/4"C. MP 15/2P 2#12, 1 # 12G., 3/4"C. HPR 25/2P 2#10, 1#10G., 3/4"C. HPR 15/3P 3#12, 1 # 12G., 3/4"C. MP 20/1P 2#12, 1#12G., 3/4"C. MP 15/1P 2#12, 1#12G., 3/4"C. MP 20/1P 2#12, 1#12G., 3/4"C. HPR 20/1P 2#12, 1#12G., 3/4"C. HPR 15/1P 2#12, 1#12G., 3/4"C. HPR 2#12, 1#12G., 3/4"C. 20/1 P 2#12, 1 # 12G., 3/4"C. GPR 20/1 P 2#12, 1 # 12G., 3/4"C. GPB MP GPB HPB** MP 0@ ELECTRICAL CONNECTIONS ® Z ❑s IsDF' CP V VFD REMARKS FOR ELEVATOR MACHINE RM FED FROM OUTDOOR HP UNIT *FOR EUH-1A,1C,2A ON STAND—BY POWER ON STAND—BY POWER ** TEMPORARY FED FROM THE HOUSE PANEL ***FOR CUH-3,4,5,7,8 * ALL DEF's SHALL BE FED FROM THREE (3) 20A/1P CB's. ** WIRE TO NEAREST HALLWAY RECEPTACLES BRANCH CIRCUIT ON STAND—BY POWER NEMA-4x ENCLOSURE ON STAND—BY POWER a. ELECTRICAL INSTALLER SHALL PROVIDE ALL STARTERS AND DISCONNECTS WHICH ARE NOT FURNISHED BY HVAC OR PLUMBING CONTRACTORS AND SHALL MAKE ALL FINAL POWER CONNECTIONS, INCLUDING TERMINATION AT EQUIPMENT, CONTROL AND INTERLOCK WIRING, AND TIE—IN TO FIRE ALARM SYSTEM IF REQUIRED, WHICH IS NOT NECESSARILY SHOWN ON THE ELECTRICAL PLANS. b. ALL EXTERIOR DISCONNECT SWITCHES SHALL BE IN NEMA-3R ENCLOSURE, U.N.O. c. PROVIDE 120 VOLT POWER CONNECTIONS TO ALL MOTORIZED DAMPERS. BRANCH CIRCUITS SCHT,'DULT,' 120 & 277 CIRCUIT BREAKER 15A-1P or 20A-1 P 30A-1P 40A-1P 50A-1P 208 & 480 15A-2P or 20A-2P 30A-2P 40A-2P 50A-2P 60A-2P 208 & 480 15A-3P or 20A-3P 30A-3P 40A-3P 50A-3P 60A-3P VOLT, 10, 2W. CIRCUITS CONDUCTOR 2 #12, 1 #12 GND., 3/4"C. 2 #10, 1 #10 GND., 3/4"C. 2 #8, 1 #10 GND., 3/4"C. 2 #6, 1 #10 GND., 3/4"C. VOLT, 10, 2W. CIRCUITS 2 #12, 1 #12 GND., 3/4"C. 2 #10, 1 #10 GND., 3/4"C. 2 #8, 1 #10 GND., 3/4"C. 2 #6, 1 #10 GND., 3/4"C. 2 #6, 1 #10 GND., 3/4"C. VOLT, 30, 3W. CIRCUITS 3 #12, 1 #12 GND., 3/4"C. 3 #10, 1 #10 GND., 3/4"C. 3 #8, 1 #10 GND., 3/4"C. 3 #6, 1 #10 GND., 3/4"C. 3 #6, 1 #10 GND., 3/4"C. 208Y/120 & 480Y/277 VOLT, 30, 4W. CIRCUITS 15A-3P or 20A-3P 30A-3P 40A-3P 50A-3P 60A-3P 4 #12, 1 #12 GND., 3/4"C. 4 #10, 1 #10 GND., 3/4"C. 4 #8, 1 #10 GND., 3/4"C. 4 #6, 1 #10 GND., 1"C. 4 #6, 1 #10 GND., 1"C. NOTES: 1. ALL BRANCH CIRCUIT CONDUCTOR SIZES ARE BASED ON RACEWAY LENGTH OF 75 FT FOR 120V CIRCUITS OR 160 FT FOR 277V CIRCUITS. IF LENGTH EXCEEDS THESE NUMBERS, THEN USE WIRE SIZE #10. IF LENGTH EXCEEDS 125FT (120V) OR 265FT (277V), THEN USE WIRE SIZE #8, U.N.O. 2. REDUCE LARGE CABLE SIZES IN JUNCTION BOX PRIOR TO DEVICE TERMINATION. PROVIDE WIRE REDUCERS AT CIRCUIT BREAKERS IF REQUIRED. PARTIAT, LIST OF ABBRT,' A AMPERES ADA AMERICANS WITH DISABILITIES ACT AFF ABOVE FINISHED FLOOR AFC' ARC —FAULT CIRCUIT INTERRUPTER AIC AMPERE INTERRUPTING CAPACITY AL ALUMINUM AWG AMERICAN WIRE GAUGE C CONDUIT CB CIRCUIT BREAKER CLG CEILING CU COPPER DW DISH WASHER EC EMPTY CONDUIT EM EMERGENCY EWC ELECTRIC WATER COOLER FA FIRE ALARM FT FEET FP FIRE PROTECTION G,GND GROUND GD GARBAGE DISPOSAL GFCI GROUND —FAULT CIRCUIT INTERRUPTER HP HORSEPOWER DW LLING LOW V TV V P/TV v 7IATIONS HVAC HEATING, VENTILATING AND AIR CONDITIONING HWH HOT WATER HEATER MCB MAIN CIRCUIT BREAKER MLO MAIN LUGS ONLY MW MICROWAVE NIC NOT IN CONTRACT NTS NOT TO SCALE PC PLUMBING CONTRACTOR ST SHUNT TRIP REF REFRIGERATOR REC RECEPTACLE UC UNDER COUNTER UG UNDERGROUND U.N.O. UNLESS NOTED OTHERWISE V VOLT W WATT WP WEATHERPROOF WG WIRE GUARD 7OLTAG SYSTT,'MS — PHONE (VOICE) OUTLET WITH CAT 5E PHONE JACK. PROVIDE 1—GANG BACKBOX WITH (1) CAT 5E CABLE TO THE TENANT MEDIA PANEL. — TV CABLE OUTLET WITH CABLE TV JACK. PROVIDE 1—GANG DEEP BACKBOX WITH (1) RG-6 CABLE TO THE TENANT MEDIA PANEL. — TV CABLE/PHONE OUTLET WITH CABLE TV JACK AND CAT 5E PHONE JACK. PROVIDE 1—GANG DEEP BACKBOX WITH (1) CAT 5E CABLE AND (1) RG-6 CABLE TO THE TENANT MEDIA PANEL. 77 — MEDIA PANEL FOR TELEPHONE AND CATV REFER TO SHEET E3.2 FOR WIRING DIAGRAM LIGHTING T,'QUIPIVIT,'NT (REFER TO LIGHTING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION) A LIGHT FIXTURE TYPE I 16 BRANCH CIRCUIT DESIGNATION. a SWITCH CONTROL. AEM I • I PROVIDED WITH INTEGRAL EMERGENCY BATTERY PACK. 0 —0 qmP RH CEILING SURFACE MOUNTED. CEILING RECESSED MOUNTED. WALL MOUNTED. DIRECTIONAL. EMERGENCY LIGHTING BATTERY UNIT WITH HEADS. EMERGENCY OUTDOOR REMOTE HEAD(S) EXIT SIGN/EMERGENCY LIGHT COMBO UNIT 0 EXIT SIGN WITH DIRECTIONAL ARROWS AS SHOWN •-❑ BOLLARD LIGHT POLE, ONE LUMINAIRE EXTERIOR BUILDING PHOTOCELL LIGHTING CONTROLS CENTERLINE 4'-0" ABOVE FINISHED FLOOR (A.F.F.) SWITCH: BLANK = SINGLE POLE 3 = THREE—WAY 4 = FOUR—WAY NOTE: PROVIDE HOT, NEUTRAL, AND REQUIRED SWITCH LEGS TO EACH LINE VOLTAGE SWITCH. SECURE AND CAP UNUSED NEUTRAL FOR FUTURE USE. ❑D SLIDE DIMMER 600—WATT DECORA SWITCH Os OCCUPANCY LINE VOLTAGE SENSOR — WALL MOUNTED os OCCUPANCY LINE VOLTAGE SENSOR — CEILING MOUNTED © LIGHTING CONTACTOR T T,'L T,'CO MMUNI CA T IO NS S YS T T,'MS CENTERLINE 18" A.F.F. EXCEPT AS NOTED. ALL TEL/DATA WIRING SHALL BE PROVIDED UNDER THIS PROJECT SCOPE OF WORK d TELEPHONE/DATA OUTLET WITH TWO (2) JACKS, U.N.O. d DATA OUTLET WITH TWO (2) DATA JACKS, U.N.O. d TV TV OUTLET WITH QUAD SHIELDED SERIES 6 CABLE TELEPHONE OUTLET NOTE: UNLESS NOTED OTHERWISE, PROVIDE 4" SQUARE BACKBOX WITH SINGLE GANG PLASTER —RING AND MINIMUM 1" CONDUIT WITH CAT-5e DATA CABLE FROM OUTLET BOX EXTENDED 6" UP TO ABOVE NEAREST ACCESSIBLE CEILING, CABLE TRAY, OR TEL/DATA ROOM TERMINATED WITH INSULATED BUSHING. PROVIDE WITH COVER PLATE WHEN NOT IN USE. R T,'C T,'PT AC L T,'S CENTERLINE 18" A.F.F. EXCEPT AS NOTED. NUMERAL INDICATES CIRCUIT NUMBER. - e IZI VFD ❑s 7p CP 125V, 2—POLE, 3 WIRE, 20A DUPLEX RECEPTACLE DESIGNATIONS: — MOUNTED ABOVE COUNTER OR BACKSPLASH WP — WITH WEATHERPROOF 'EXTRA —DUTY' COVER UC — UNDER COUNTER MOUNTED GF — PROTECTED BY GROUND FAULT CIRCUIT BREAKER EV — ELECTRIC VEHICLE CHARGING OUTLET P — PEDESTAL MOUNTED DUPLEX WITH GROUND FAULT PROTECTION. SINGLE RECEPTACLE DOUBLE DUPLEX RECEPTACLE. SWITCHED DUPLEX RECEPTACLE. ELECTRIC DRYER OUTLET. PROVIDE NEMA 14-30. VERIFY WITH LAUNDRY EQUIPMENT VENDOR PRIOR TO ROUGHING. MOTOR CONTROLS MOTOR, NUMERAL INDICATES HP. INSTALLED AND WIRED BY ELECTRICAL. MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PROTECTION VARIABLE FREQUENCY DRIVE — WIRED BY ELECTRICAL. MAGNETIC ACROSS THE LINE MOTOR STARTER. COMBINATION MAGNETIC STARTER WITH PILOT LIGHT AND FUSED SWITCH. CONTROL PANEL FOR PACKAGED EQUIPMENT FURNISHED BY OTHERS — WIRED BY ELECTRICAL. MECHANICAL EQUIPMENT TAG FOR ELECTRICAL CONNECTION. SEE MECHANICAL EQUIPMENT SCHEDULES. MI SC T,'LLA NT,'O US SURFACE PANELBOARD = FLUSH MOUNTED LOAD CENTER DISCONNECT SWITCH — FUSED DISCONNECT SWITCH — UNFUSED ENCLOSED CIRCUIT BREAKER 0 JUNCTION BOX — CEILING MOUNTED —0 JUNCTION BOX — WALL MOUNTED ❑-' IC RGA GB Tr MULTY—FAMILY INTERCOM SYSTEM REMOTE GENERATOR ANNUNCIATOR GROUND BUS P2-2 HOMERUN 2#12 & 1#12GND IN 3/4"C CONNECTED TO 20A/1P CIRCUIT BREAKER. 'P2' REPRESENTS PANEL NAME. '2' INDICATES CIRCUIT NUMBER IN PANEL. E0.1 E1.OSB E1.0 E1.1 E1.2 E1.3 E1.4 E1.5 E1.6 E1.7 E2.1 E3.1 E3.2 E3.3 E4.1 E4.2 DRAWING LIST ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL LEGEND & SCHEDULES SUB —BASEMENT PLAN BASEMENT PLAN FIRST FLOOR PLAN SECOND FLOOR PLAN THIRD FLOOR PLAN FOURTH FLOOR PLAN FIFTH FLOOR PLAN SIXTH FLOOR PLAN ROOF PLAN TYPICAL ENLARGED UNIT PLANS POWER RISER DIAGRAM LOW VOLTAGE ONE —LINE DIAGRAMS DETAILS LIGHTING FIXTURE SCHEDULE PANELBOARD SCHEDULES E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 Ica IL u:Li cn 0 a CC 0_ c) C C 0_ ArchitectureSite W cn UD UD W CC CO CD CC 0_ F- u CD F 246 Walnut Street ao CQ W Q J SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: U) 0 z Q z di z W ELECTRICAL t�,ofi� O ADAM yG z DAVIDSON m g ELECTRICAL - NO. 5D519 i/ irk TE fti L DRAWING #: HDf X co co co co L() ti co TS ©TISE DESIGN ASSOCIATES, INC 2019 a Q N • non N aco In N a iA 29' —12„ 16'-2' II II I I I II �I I I I I I I I I I II I - I 16' — SJB SCA BAS e1/ 8 99 i \T 12' — 99 17'-78" r 11' 48„ 5'— OOR P RA\ 16'- 13' — 5' i 12'5" 7'— 12' — 7„ 14' — 1'' SUB —BASEMENT ELECTRICAL NOTES: 1. ALL LIGHTING SHALL BE WIRED TO HOUSE PANEL 'HPB' CKT #34. 2. ALL POWER RECEPTACLES SHALL BE WIRED TO HOUSE PANEL 'HPB' CKT#36. 3. REFER TO HVAC AND PLUMBING DRAWINGS FOR LOCATION AND POWER REQUIREMENTS OF MECHANICAL EQUIPMENT. MECHANICAL EQUIPMENT ON SUB —BASEMENT LEVEL SHALL BE CIRCUITED TO PANEL 'MP', U.N.O. rKV to N E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 W C W C/D O d CC 0 W F- PROGRESS SET CO C\ J UILDINC f EIIMIT CET MAR 22,2019 BUILDING PERMIT SET O 0 246 Walnut Street X CO CO O � N CO v) 0 Co co N 2 N a) CD 0 • Z co SCALE: 1"=8'-0" PROJECT#: SALEM, MASSACHUSETTS 01970 URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: I Zyi OF 1Hq ADAM DAVIDSON ELECTRICAL NO. 50519 SSlQMAL ' l TEas° DRAWING #: co co SUB -BASEMENT ELECTRICAL ©TISE DESIGN ASSOCIATES, INC 2019 0 N N ' co N \ 16'-4 I I II �I I I I I I I I I I I — I I I II I II II II I I II II BAS SCAL 16' 4s- \T /8" P I I 29'-12„ 99 63'- 1 2' — 17' 7g 81 51'- CDj 16'- 25' STAIR 1 GPB UH v I EL EV f Ir,: P • DN CUH 3 2 UP DN — R1 01* R01* METER SOCKETS LOW ER LOBBY R01 111 14 • ■ �M ►�� 12 DP LS 0GPB ATS2 MP 1 * LC HPB IC _ LS 1* FL-C I NIL AL CCV� EB MSB 302 * 1— LS I— — GPB:#1> 14GB I G 1-1—r 3/4" PLYWOOD Bi6kCKBOARD 11 48 LS PP1 SM1&2 1* PP2 12 ..❑ 5 6 0 GF O EV GF w GF GF EV EV EV GF GF -eEV 14 14 GT 6 GT 6 M GT I►� 2XEM GF GF 1* EVO-t-e EV 0 0 G{ 1* ySL 14 GEM H DB:6 GEM 1*�SL RAIV He PEDESTAL TYPICAL 13 — 0 D 110 GEM 0 GEM 1* SL l\\ 7A ' " 7 7 ),\ 7 7\ / 7 / . 11111 7 )111,,▪ ' EXACT LOCATION TBD. DP: 100A/2P CB 2#2, 1#8G, 1-1/4"C. S TAIR 4 UP Z i XEMR G` X T®T1 * 6 6 fit EV GF P GF EV GEJ G T G TEV GF P SL 6 6 GF EA I] EV 0 1* LOW OUNTED. UNSWITCHED SECURITY LIGHT. TYPICAL ER GARAG B05 GEM 12'- 6 11 GF GT y' 6 25' INTEGRATED 'ON/OFF' MOTION SENSOR TO CONTROL INDIVIDUAL FIXTURE. TYPICAL i GT 6 ❑v 12' — 0 GF 211 i G GF GF tV P G" GEM 0 EV III Em EV 0 G" GEM GF 14' — El 6 6 (Tl 25'-3" (EUH) GF GF EVe-we EV P 0 1* EV 0 r: 0 GF G- 6 Ed GEM 6 III 14 GF 11'104" 11' EV 1, 4 C O GF O NKO Moo rn \ ,00 C BASEMENT ELECTRICAL NOTES: 1. ALL COMMON AREAS EGRESS LIGHTS AND PARKING UNSWITCHED SECURITY LIGHTING WITH SUBSCRIPT 'SL' SHALL BE CIRCUITED TO STANDBY GENERATOR PANEL "GPB", U.N.O. NOTE: STAND—BY GENERATOR BRANCH CIRCUITS INDICATED WITH '*'. 2. EXIT SIGNS AND EMERGENCY BATTERY UNITS SHALL BE CONNECTED AHEAD OF SWITCHED LEG OF BRANCH CIRCUIT SERVING COMMON AREAS LIGHT FIXTURES. 3. PARKING GENERAL LIGHTING SHALL BE CIRCUITED TO BUILDING PANEL "HPB", U.N.O. 4. ALL COMMON AREAS POWER BRANCH CIRCUITS SHALL BE CIRCUITED TO BUILDING PANEL "HPB", U.N.O. 5. REFER TO 'MECHANICAL EQUIPMENT SCHEDULE' ON SHEET E0.1 FOR POWER CONNECTION AND WIRING INFORMATION. 6. ALL ELECTRIC VEHICLE CHARGING RECEPTACLES WITH SUBSCRIPT 'EV' SHALL BE WIRED TO PARKING PANEL "PP1 ". EACH 'EV' RECEPTACLE SHALL BE FED FROM INDIVIDUAL GFCI CIRCUIT BREAKER. KEYED NOTES: @i ELECTRICAL SERVICE FROM UTILITY UNDERGROUND TRANSFORMER. ® CABLE TV, PHONE&DATA SERVICE. PROVIDE 2-4"CONDUITS. COORDINATE ROUTING WITH TELECOM UTILITY COMPANY. ® MAIN INTERCOM CONTROL UNIT. ® PROVIDE ROUGHING FOR FUTURE TESLA CHARGING STATION. PROVIDE EMPTY 1" CONDUIT WITH PULL STRING TO PHONE/DATA ROOM FOR FUTURE 'POS' CONNECTION. E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 W C w F ArchitectureSite Planning Project Management CO F- u CD H— r MAR 22,2019 BUILDING PERMIT SET O M0 U) 246 Walnut Street X 4— O QD co N CO :) N cn 0 CO co N (a 2 O a> (0 •> C • N Z co SCALE: 1"=8'-0" PROJECT#: F- z 0 c� SALEM, MASSACHUSETTS 01970 URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: tyi OF Abq ADAM DAVIDSON ELECTRICAL NO. 50519 ,/ Yr� TE ►JHAL DRAWING #: a ©TISE DESIGN ASSOCIATES, INC 2019 n GPB:#33,35 2 # 1 0 , 1 # 1 0 G , 3/4"C. 0 �4/- PT-1 I COORDINAT = EXACT LOCATION OF ARTW^,RK PANELS WITH ARCHITECII,RAL ELEVATIONS. —P'CAL-TO R ALL. RC-1 16-4 EM 11* III SL GF e19 EV L GF EV B-2 -,GF'� EV G EV RB-2 I30 GF EV RB-2 -V 13* 8 GT 8 GT 8 1.1 GARAG 29 1» 63'— G { GEM 8 U 108 8 g Ogg 1 SL— QE1 fi 11* GT G 8 fJ HPB: 40A/3P CB 3#8, 1 # 1 OG, 3/4 jC. TR // ROM/ /// _z7 /LS /• RB-2 8 \ HPB:3Q rVIA 'LC\ WINDOW DISP 8 - EB LS i 8 I �8 Tin GEM GPB:#1 1 �! CONTROL PANEL FIELD COORDINAT AND POWER RE G� HPB:BE, 'RC`- ILLUM I NAT10 N_JJ, SL PARKING LI CT LOCATI NTS. E2B \ 16 LS F 8 Q� 9,1 D R 11 Ss 16 17' GT c V" 11* R1 EB 0R1 X T® 11* 16 8 8 CF EV & LOBBY HPB: FW IBU RAM G XEM (yl* 11 0 AEA Et-GFT HPB: 40A/3P CB 3#8, 1 #1 OG, V4"C. -R1 14P130 3 11"11 11* " RI lei 7 XEMR /32 GLASS TNOPY 23 91211 102 El CONTROL PANE FIELD COOR AND POW STEP LI4IT(TY11) G FOR PARKING LIFTS. ATE EXACT LOCATION REQUIREMENTS. HPB:#42 LS HPB: #40 SW-4 4 FW 3.1 EV TAIL 107 40 42 L LED FOCUSED S OT FIXTURE. TYPICAL FOR TW . A S EX STI\G BUILD 32 CHURCH ST. LS 40 8 RETAIL SPACE LIGHTING, RECEPTACLE AND \ IC ELECTRIC UNIT HEATERS SHALL BE TEMPORARY WIRED TO BUILDING PAN L 'HPB'. LS 40 STEP G 42 8 LS XEM XEM 40 LS 40 40 2 FIRST FLOOR ELECTRICAL NOTES: 1. ALL COMMON AREAS EGRESS LIGHTS AND PARKING UNSWITCHED SECURITY LIGHTING WITH SUBSCRIPT 'SL' SHALL BE CIRCUITED TO STANDBY GENERATOR PANEL "GPB", U.N.O. NOTE: STAND—BY GENERATOR BRANCH CIRCUITS INDICATED WITH 2. EXIT SIGNS AND EMERGENCY BATTERY UNITS SHALL BE CONNECTED AHEAD OF SWITCHED LEG OF BRANCH CIRCUIT SERVING COMMON AREAS LIGHT FIXTURES. 3. PARKING GENERAL LIGHTING SHALL BE CIRCUITED TO BUILDING PANEL "HPB", U.N.O. 4. ALL COMMON AREAS POWER BRANCH CIRCUITS SHALL BE CIRCUITED TO BUILDING PANEL "HPB", U.N.O. 5. REFER TO 'MECHANICAL EQUIPMENT SCHEDULE' ON SHEET E0.1 FOR POWER CONNECTION AND WIRING INFORMATION. 6. ALL ELECTRIC VEHICLE CHARGING RECEPTACLES WITH SUBSCRIPT 'EV' SHALL BE WIRED TO PARKING PANEL "PP2". EACH 'EV' RECEPTACLE SHALL BE FED FROM INDIVIDUAL GEC' CIRCUIT BREAKER. KEYED NOTES: ® GARAGE DOOR CONTROLLER. PROVIDE ALL REQUIRED WIRING AND CONNECTIONS P E R MANUFACTURER'S RECOMMENDATIONS. ® PROVIDE DIRECT —VIEW TRAFFIC CONTROLLER "CAUTION VEHICLE EXITING". COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH ARCHITECT PRIOR TO ROUGHING. TRAFFIC CONTROLLER SHALL BE DIRECT —VIEW LED TRAFFIC CONTROLLER TCL1418A—A172 BY SIGNAL —TECH OR APPROVED EQUAL. PEDESTRIAN ALERT SYSTEM SHALL BE TRIGGERED BY ONE OF THE FOLLOWING: a. CONCRETE EMBEDDED ACTIVATION LOOPS; b. WALL MOUNTED ULTRASONIC VEHICLE DETECTORS USVD-4X: c. ROLL —UP DOOR; d. DRIVER'S WIRELESS DEVICE. COORDINATE SELECTION OF THE TRIGGERING DEVICE AND ALL WIRING REQUIREMENTS WITH A VENDOR. ® PROVIDE FLASHING ILLUMINATED WARNING SIGN "CAUTION PEDESTRIAN CROSSING" INSIDE GARAGE TO DRIVERS EXITING THE GARAGE AND ABOUT TO CROSS A PUBLIC SIDEWALK. THE SIGN SHALL BE BLANK —OUT LED BACKLIT SIGN MODEL PHX1418R—B244 BY SIGNAL —TECH OR APPROVED EQUAL. COORDINATE EXACT LOCATION WITH ARCHITECT AND LOCAL BUILDING INSPECTOR PRIOR TO ROUGHING. • DIRECT —VIEW RAMP TRAFFIC CONTROL SIGN TO NOTIFY DRIVERS EXITING THE GARAGE ABOUT INCOMING VEHICLE FROM THE STREET (TOTAL OF TWO). TRAFFIC CONTROL FIXTURE SHALL BE DIRECT —VIEW LED TRAFFIC CONTROLLER TCL147RG-225H BY SIGNAL —TECH. COORDINATE EXACT LOCATION WITH ARCHITECT AND LOCAL BUILDING INSPECTOR PRIOR TO ROUGHING. PROVIDE TRAFFIC CONTROL PANEL/RELAY, VERIFY METHOD OF SIGNS ACTIVATION AND WIRING WITH VENDOR. ® ELECTRIC DOOR STRIKE FOR INTERCOM SYSTEM. PROVIDE POWER SUPPLY FOR THE STRIKE. ® INTERCOM. COORDINATE LOCATION WITH OWNER/ARCHITECT PRIOR TO ROUGHING —IN. • REMOTE STANDBY GENERATOR ANNUNCIATOR. FINAL LOCATION TBD. • NATIONAL GRID PADMOUNT TRANSFORMER APPROXIMATE LOCATION. COORDINATE EXACT LOCATION AND PAD DIMENSIONS WITH NATIONAL GRID AND CIVIL ENGINEER PRIOR TO STARTING ANY WORK. REFER TO PAD MOUNT TRANSFORMER AND TRAFFIC PROTECTION BOLLARD DETAILS ON SHEET E3.3. EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ,-;-,ALL RIGHTS RESERVED a) a) a) CL CC PROGRESS SET CO SCALE: 0 SALEM, MASSACHUSETTS 01970 UILDINC PEWIT CET MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: 114 OF ADAM DAVIDSON ELECTRICAL NO. 50519 DRAWING #: 246 Walnut Street CO CV cn cn cn ai cn ELECTRICAL cen cn '1 1 CO CO LO CO CO CO 00 ©TISE DESIGN ASSOCIATES, INC 2019 oc B1 0A 2003 OA A oc oc O OA 1\\ 41 \ 0204 A OA I�\ II II II II — V O rF C I I � I I oc OA Al 805 oc Q 0 OA P OA V OA OA oc OA OA -❑ II OP II II II II II II I OA I 206 II II II OA I I II II II II II I OA \OA I I L 63'-1 R„ OA EB 7* aOR1 1 z J 7* 7* a OR1 X Kr 7* OA 7* - 3 a OR1 OA OA oc * 1A S L-IT02 A OA OA OA LC 1 oc OA C ■ AFFORDABLE 202 OC oc DIOA I 2, A OA 7* ale 15 T3 MB2 n�l� I I F 4 FI 0 4-M PITCHY PER 2 WP b _ 6 — 64' 10 Oc8 OOT PITCH Y4" PER FOOT /-PT-1 �10 08 CON/ CM4 Tr 8 oCM4 OM4 �10 80CM4 oc 9144 agJi '13 ea 01 EB n 1 GPB:#7 a CM1 211 T PITCH Y4" PER FOOT \\ PITCH Y4" PER FOOT // RR / / / / / / IJ\ os 12 • \ / \ / > (X < \AD AC- / / N' // PITCH 4" PER FOOT\ / / P1b P1a �V_\ TO-/i B-V// 08 CM4 oc PT-1-- ti 7 15(ga , F I T EB7*o It 3 XEM PANEL — 'HP2' I DORXW 7* ao * 7*4 EB LC 1-1 — —0— oc 212 II II II II 6 WP1' >\< o 7* a R1 LJ REF CIRCUIT ALL BRANCH CIRCUITRY TO PANEL 'HP2', U.N.O. oc CONDO MEDI TYPICAL. 13 V4 OA OA L93-- OA AFFORDABLE 207 OA OA L oc J CO _OAD C=NTER TYPICAL. C OA OA OA 7* O 0R1 1 J Oa XEM a oR� — OS I *51�SF-2 X os Oaa 0EB 7* aoR1 7* TOT �15 7* 00 Op > - < K - 0 - oc J r oc oc 0- 0 0 OA OA LC LC OA OA OA 43 Gol 2043A OA RD OA OA oc OA OA oc OA OA OA SECOND FLOOR ELECTRICAL NOTES: 1. SINGLE-PHASE PANEL "HP2'' SHALL FEED ALL LIGHTING AND POWER BRANCH CIRCUITS WITHIN COMMUNITY ROOM, FITNESS CENTER, RESTROOMS AND EXTERIOR DECK ON THIS FLOOR. 2. CORRIDOR LIGHTING FIXTURES 'R1' AND 'R2', EMERGENCY LIGHTING AND EXIT SIGNS SHALL BE CIRCUITED TO STANDBY GENERATOR PANEL ''GPB", U.N.O. ALL OTHER COMMON AREAS LIGHTING FIXTURES SHALL BE CIRCUITED TO PANEL ”1-1PB”, U.N.O. NOTE: STAND-BY GENERATOR BRANCH CIRCUITS INDICATED WITH '*'. 3. CORRIDOR'S MOTION SENSORS SHALL DIM FIXTURES 'R1' AND 'R2' TO APPROXIMATELY 30% WHEN CORRIDOR IS UNOCCUPIED. 4. CIRCULATION AREAS POWER AND HVAC SHALL BE CIRCUITED TO BUILDING PANEL ”1-1PB”, U.N.O. 5. EXIT SIGNS AND EMERGENCY BATTERY UNITS SHALL BE CONNECTED AHEAD OF SWITCHED LEG OF BRANCH CIRCUIT SERVING COMMON AREAS LIGHT FIXTURES. 6. REFER TO DWELLING UNIT ENLARGED PLANS ON DRAWINGS E2-SERIES FOR TYPICAL ELECTRICAL LAYOUT. EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ,-;-,ALL RIGHTS RESERVED Ew a) a) a - a) CID CL CC PROGRESS SET CO SCALE: 0 SALEM, MASSACHUSETTS 01970 246 Walnut Street MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: OF Ati ADAM DAVIDSON ELECTRICAL NO. 50519 DRAWING #: ,94 CN LO c co Z CO 0 ELECTRICAL (11 L 2 ©TISE DESIGN ASSOCIATES, INC 2019 I OA oc 0O -�u a0 TF I T A) r0 I IMP aO I O DO I A I yo r -V SCA 305 L ,O OA OA it l �: a \ III I I I I L _ - OA 306 OA o OA 0A OW - T cb 99 63'-12 EB aoR9* 9* 9 a OR1* 9 I3 0OR1 15 9* °R9* OA ASL T02 13 OA -a- 1 oc OA 1::1 2 AFFORDABLEo A oc 35 11 A oc T cta r 015 oc OA LC oc FE OA OA 1 LC IL 1- -1111 11 11 11 OA OA OA OA REF OA 313 REF OP OA 307 OA OA OA oc 0AE 3A AFFORDABLE 312 oc LC I oB REF oc OA OA OA OA OA 308 oc oc OA TE os oc EB ao XEM X OK oc CT LC OA OA OA vct OA OA 309 OA 310 OA OA OA OA OA 41,4 oc oc OA OA OA THIRD FLOOR ELECTRICAL NOTES: 1. CORRIDOR LIGHTING FIXTURES 'R1' AND 'R2', EMERGENCY LIGHTING AND EXIT SIGNS SHALL BE CIRCUITED TO STANDBY GENERATOR PANEL ''GPB", U.N.O. ALL OTHER COMMON AREAS LIGHTING FIXTURES SHALL BE CIRCUITED TO PANEL "HPB", U.N.O. NOTE: STAND—BY GENERATOR BRANCH CIRCUITS INDICATED WITH I'''. 2. CORRIDOR'S MOTION SENSORS SHALL DIM FIXTURES 'R1' AND 'R2' TO APPROXIMATELY 30% WHEN CORRIDOR IS UNOCCUPIED. 3. CIRCULATION AREAS POWER AND HVAC SHALL BE CIRCUITED TO BUILDING PANEL ''HPB", U.N.O. 4. EXIT SIGNS AND EMERGENCY BATTERY UNITS SHALL BE CONNECTED AHEAD OF SWITCHED LEG OF BRANCH CIRCUIT SERVING COMMON AREAS LIGHT FIXTURES. 5. REFER TO DWELLING UNIT ENLARGED PLANS ON DRAWINGS E2—SERIES FOR TYPICAL ELECTRICAL LAYOUT. EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED Ew a) co a) a) CC PROGRESS SET CO C\J SCALE: 0 SALEM, MASSACHUSETTS 01970 UILDINC PEWIT CET 246 Walnut Street MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: OF Ati ADAM DAVIDSON ELECTRICAL NO. 50519 DRAWING #: CO CN c co ELECTRICAL cn L 3 ©TISE DESIGN ASSOCIATES, INC 2019 1 O aL�°w r _� c�0 I I T 1 1 I I 1 1 1 r0 MP ,O I I s° s0 sdp \n:n I s0 s0 405 OA OA L OA TF L _ 406 OA 4 /8" FLO I _ T s0 LW i _ o OA 99 4 63'-117- a0R2* 1 2* osa1 °I * a°R11217 TalA, \ A a OR12* 12* w/ B I ®Tx 2* L OA I1m ,Ip gFiW F oc ea 9 OA - 0 7 oc °ACI AFFORDABLE 402 oA_ 408 oc A oc T OA 51'- oc LC qo do os ao12;` R:#12 R1 OA LCII OA oc OA REF K 407 OA OA OA OA OA OA OA OA OA E 413 REF O I❑ ' of 1 OA C °E2 412 DOH �12* 42* 170 12*t EB 1>< oc oc REF OA aoR112* REF i oc OA OA J 9*FFORDALE 408 OA oc oc ci OK OA OA OA 9 TEF OA OA [I Lc °A EB a01 2* R 12* 17 12* aOR1 Oa XEM X 12* EB ao1 R1 * T®T G �17 12* oc T oc oc OA OA lo OA OA OA OA OA OA OA 409 G OA 410 OA OA OA OA oc oc OA FOURTH FLOOR ELECTRICAL NOTES: 1. CORRIDOR LIGHTING FIXTURES 'R1' AND 'R2', EMERGENCY LIGHTING AND EXIT SIGNS SHALL BE CIRCUITED TO STANDBY GENERATOR PANEL ''GPR'', U.N.O. ALL OTHER COMMON AREAS LIGHTING FIXTURES SHALL BE CIRCUITED TO PANEL "HPR", U.N.O. NOTE: STAND-BY GENERATOR BRANCH CIRCUITS INDICATED WITH '*'. 2. CORRIDOR'S MOTION SENSORS SHALL DIM FIXTURES 'R1' AND 'R2' TO APPROXIMATELY 30% WHEN CORRIDOR IS UNOCCUPIED. 3. CIRCULATION AREAS POWER AND HVAC SHALL BE CIRCUITED TO BUILDING PANEL "HPR" LOCATED ON THE ROOF, U.N.O. 4. EXIT SIGNS AND EMERGENCY BATTERY UNITS SHALL BE CONNECTED AHEAD OF SWITCHED LEG OF BRANCH CIRCUIT SERVING COMMON AREAS LIGHT FIXTURES. 5. REFER TO DWELLING UNIT ENLARGED PLANS ON DRAWINGS E2-SERIES FOR TYPICAL ELECTRICAL LAYOUT. It EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ,-;-,ALL RIGHTS RESERVED a) co a) a) CID CL CC PROGRESS SET CO SCALE: 0 SALEM, MASSACHUSETTS 01970 246 Walnut Street MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: • ELECTRICAL jAV;DA MF 1:: 11°4 co DRAWING #: CO CO ©TISE DESIGN ASSOCIATES, INC 2019 o. O � ❑. L oc OA OA B 503 cO OA OA 504 OA OA '0 �O ciP 0 o oo L o_ v J cP I I \ A I 0 aO REF 505 cp oW OA °A r- I I OA L I °A 506 I o O to A A A I LJ `, CA L 5/8 Ji _J o OA 63'- 0 F� K L_- a10*�\ .F Q_ oN o 0� EB tool 0* R1 10* ao:p* OA 10* OA oc OA OA 0 OA A 502 508 FC trtrkir oc A oc oc oc oc OA OA 013 oc oc OA OA LC qo do REF 08 93 507 OA OA OA OA OA OA OA OA OA OA E 1°A 513 I DV II I I II REF El E oc 0A E 512 oc LC DW OA OP OA CI01 0* RI REF 93 oc OA :10A OA 0 oc oc OA OA 1>c< oc OA 10* 13 RI Oa XEM RI OK oc OA OA LC Elt OA OA OA OA LJ OA HA 509 OA OA OA OA FIFTH FLOOR ELECTRICAL NOTES: CORRIDOR LIGHTING FIXTURES 'R1' AND 'R2', EMERGENCY LIGHTING AND EXIT SIGNS SHALL BE CIRCUITED TO STANDBY GENERATOR PANEL "GPR", U.N.O. ALL OTHER COMMON AREAS LIGHTING FIXTURES SHALL BE CIRCUITED TO PANEL "HPR", U.N.O. NOTE. STAND-BY GENERATOR BRANCH CIRCUITS INDICATED WITH '*'. 2. CORRIDOR'S MOTION SENSORS SHALL DIM FIXTURES 'R1' AND 'R2' TO APPROXIMATELY 30% I WHEN CORRIDOR IS UNOCCUPIED. 3. CIRCULATION AREAS POWER AND HVAC SHALL BE CIRCUITED TO BUILDING PANEL "HPR" LOCATED ON THE ROOF, U.N.O. 4. EXIT SIGNS AND EMERGENCY BATTERY UNITS SHALL BE CONNECTED AHEAD OF SWITCHED LEG OF BRANCH CIRCUIT SERVING COMMON AREAS LIGHT FIXTURES. 5. REFER TO DWELLING UNIT ENLARGED PLANS ON DRAWINGS E2-SERIES FOR TYPICAL ELECTRICAL LAYOUT. OA OA oc oc OA OA OA EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED liLf ArchitectureSite Planning Project Management LLJ Li up LLJ cC CO SCALE: SALEM, MASSACHUSETTS 01970 246 Walnut Street 9 BUILDING PERMIT SET cc URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: ADAM DAVIDSON ELECTRICAL NO. 50519 DRAWING #: cdo 71- CO CN c c▪ o ELECTRICAL L 5 ©TISE DESIGN ASSOCIATES, INC 2019 oc O OA A B2° OA SC 603 oc oc OA OA A29 604 V A OA oc oc OA oc II 6 II I I 1 OA ow LCC-- OA C^I'- T DW OA I �C I ❑I - 1C DC 1 1 X20A 16A0 5 OA oc _ Q � O ow OA L I— L OA OA 606 OA OA C /8" OA OA OA OA OA J 99 1 4 REF L7 11 11 11 11 11 63'- 909 K K �I 8* r-- a Q R1 EB 8* a OR1 8* 11 11 oA1 LC 0 OA OA oc OA OA OA VL* OA 020A Ok2 oc 608 A oc oc 1 oc OA OA oc oc CC OA a 8 R:#8 as a OR1 LoA OA OA OA OA T L 7 SKYLIGHT L — J c� DC OA OA OA OA E REF 612 1 OA OA 'DE 2A 6'1 LC LC DW f j 0 op OA ob REF 71 SF-6a SF-6b ao8* 1013 1013 a R1 oc F K oc SKYLIGHT oc oc J cC OK oc OA OA 7isd T04 OS oc EB 71 EB a 8* 8 oR1 13 a 8* OR1 Oa XEM ate* R1 ;q-_pi3 8* T®TX 8* Cj oc 0 0 OA OA -- I L OA OA [ILCA m OA OA OA OA OA SIXTH FLOOR ELECTRICAL NOTES: 1. CORRIDOR LIGHTING FIXTURES 'R1' AND 'R2', EMERGENCY LIGHTING AND EXIT SIGNS SHALL BE CIRCUITED TO STANDBY GENERATOR PANEL "GPR", U.N.O. ALL OTHER COMMON AREAS LIGHTING FIXTURES SHALL BE CIRCUITED TO PANEL "HPR', U.N.O. NOTE: STAND—BY GENERATOR BRANCH CIRCUITS INDICATED WITH '*'. 2. CORRIDOR'S MOTION SENSORS SHALL DIM FIXTURES 'R1' AND 'R2' TO APPROXIMATELY 30% WHEN CORRIDOR IS UNOCCUPIED. 3. CIRCULATION AREAS POWER AND HVAC SHALL BE CIRCUITED TO BUILDING PANEL "HPR" LOCATED ON THE ROOF, U.N.O. 4. EXIT SIGNS AND EMERGENCY BATTERY UNITS SHALL BE CONNECTED AHEAD OF SWITCHED LEG OF BRANCH CIRCUIT SERVING COMMON AREAS LIGHT FIXTURES. 5. REFER TO DWELLING UNIT ENLARGED PLANS ON DRAWINGS E2—SERIES FOR TYPICAL ELECTRICAL LAYOUT. �1 616 H 1I 608 OA OA OA oc OA OA oc oc OA OA OA i C C E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc @ALL RIGHTS RESERVED Project #: 4017 E a) co C Co U a) O IZ C) C 0 a) N Pp CCU o U [C a uJ C./) 0 CL CC 0 uJ F PROGRESS SET Co 0 C\J J SCALE: PROJ ECT#: SALEM, MASSACHUSETTS 01970 246 Walnut Street MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: ZyiOF Ati ADAM DAVIDSON ELECTRICAL NO. 50519 • i/ `9S/ONAL DRAWING #: x CD 9— CO O T- C- ) CO co N Cfl C cw W � Z CO 1"=8,_ON ELECTRICAL DES ©TISE DESIGN ASSOCIATES, INC 2019 HP 36 603 HP 36 403 303 203 501 401 301 201 HP ,( 36 506 PER FOOT HP 36 406 R OOH P A\ SCALE: 1 /8"-1' PITCH /4" PER FOOT N. 306 WP (IP RD i PITCH /4" PER FOOT ml — J HP-R:#3 egA 0 0 0 GPR:#6 CORR. P01 EM— EB 1 HOT WATER CIRC. PUMP U9 cuH` ,i LS 1 GPR:15A/2P S 1 �� HP 5 -ELEC i #1 I.SR,(-) Q N 2 R04 •: _— 4 1 R ATS 1 i LS i 0 O �`6-*4g �l iI:;. ! FR GPR:h 7 - - y 607 HP 36 507 407 307 WP 3 PITCH 4" PER FOOT DEF 13 HP 30 ELEV. MACHINE FIT ROOM REFER TO ELEVATOR MACHINE ROOM DETAILS ON SHEET E3.3 1+PR.4 VIA 'TC' /4 r I lid I HHR VIA 'TC' R-5 RB-2 206 ENTRY • 53,— LC: 22,24 2#10, 1#10G, 3/4"C. (TYPICAL FOR ALL HPx UNITS) A N HP 36 607 08 3s' 409 — 509 60 -r- PITCH (DEF WP -FC11/4" REP— FOOT — PITCH Y4" PER FOOT WPEk 3 STANDBY GENERATOR ENCLOSURE 4" PER FOOT JPP 210 311 411 511 61 HP HP HP 310 410 510 RD DEF\C) PI TC ROOF ELECTRICAL NOTES: 1. STAND—BY GENERATOR BRANCH CIRCUITS INDICATED WITH '*'. 2. EXIT SIGNS AND EMERGENCY BATTERY UNITS SHALL BE CONNECTED AHEAD OF SWITCHED LEG OF BRANCH CIRCUIT SERVING COMMON AREAS LIGHT FIXTURES. 3. CIRCUIT ALL OUTDOOR DWELLING HEAT PUMP UNITS TO ASSOCIATED LOAD CENTER 'LC'. REFER TO HVAC DRAWINGS FOR HVAC EQUIPMENT EXACT LOCATION AND ELECTRICAL INFORMATION. INCREASE CONDUCTOR SIZES TO COMPENSATE FOR VOLTAGE DROP PER 'BRANCH CIRCUIT SCHEDULE' NOTES ON SHEET E0.1. 4. INDOOR HEAT PUMP UNITS SHALL BE FED FROM ASSOCIATED OUTDOOR UNIT. PROVIDE 3#12 WIRING IN 3/4" CONDUIT BETWEEN OUTDOOR AND INDOOR UNITS. VERIFY ALL WIRING WITH MANUFACTURER'S RECOMMENDATIONS. .11 EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED )1 Project #: 4017 liLf CC ArchitectureSite Planning Project Management PROGRESS SET CO SCALE: 0 SALEM, MASSACHUSETTS 01970 UILDINC f Cf1MIT CET 9 BUILDING PERMIT SET cc URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: 246 Walnut Street ireDIA"AV:1 DA MP SON ELECTRICAL NO. 50519 tn DRAWING #: 7r CO 00 c co ELECTRICAL L 7 ©TISE DESIGN ASSOCIATES, INC 2019 17 s\F — I SCAL 13 W I 17 INI MN BEDR�OM 012 M5 17 p/Tv IS al SF t 19 19 P/TV 13 Tv R CA 1/4" — O12 m 17 N L V . . B 13 CBD NG/D NING . 012 m . . 012 m 13 012 I — ASTER BEDRa2 M9 C 012 -_A P/N 13 17 9 YD 17 1?Y B \BR LIVING/DIN 012 M3 13 B 17 MASTER BE OU M9 .. D BEDROOM M5 . NG 13 . . LAUN M7 21 12 B FCU 20I W AI N I I CLbS Ii MBI -TYP- MASTER BAT 1 A2 15• 112 21\ MP $ 6 O X 21 ►r: a . Mdt �nn i Bo12 12n 9 K TC 12 k- n-bC7 — UC - I C 0 EN 12 0 DROOV 12 A2 hI,ALL ,g)21 011/ A Ic / )(1 SF TYP. A A Ok2 UC UC MASTER BAT C 81 C C A\ M2 LOW WALL —i LAUNDRY M7 HALL M1 C LAUNDRY U7 YC C A2 A9 B D C I I KB 012 W1 _FCU _ 7 17 r_ A TYP. !WALK- N 12o P/TV CLOS_ @17 6 612 21 MX LAUND Iv LC21 F.n"AFF IC D \� D 12 21@ 13 M Y 17 TP A m BR LIVING/DIN U3 13 G 12 D MASTER BEDROOM U9 C 012 VY 17 17@g 17 S A d pAv13 012 m NG A 12 A 12 Om Om II I I I I , I II I R CAB /4- 1 YB I I i I 5 I I CA LOW WALL mt)17 M WALL —IN 01 n0012 17 pm DROOV II A 1 0 21 H 3BR LIVING/DIN NG I 11 m Om� O M3 III 13P/TV 11}311 13 Q� v , la C 13 Tv 17 171:* 13 13 13@ i i C PLAY T"D IIv F _012� L. CIR CA SCALE: 1 /A" — 1 33X00 D E10 Od E 21 012 m 012 V m 13 Tv D 13@ or= RD Z19 12 0- TYP W1 A 12 GENERAL ELECTRICAL NOTES: 1. REFER TO FA100-SERIES DRAWINGS FOR DWELLING UNITS FIRE ALARM DEVICES LAYOUT. 2. ALL 15 AND 20 AMP, 1 20 VOLT RECEPTACLES WITHIN DWELLING UNITS SHALL BE TAMPER PROOF TYPE. 3. RECEPTACLE FOR DISHWASHER SHALL BE LOCATED IN THE SPACE ADJACENT TO THE SPACE OCCUPIED BY THE DISHWASHER. 4. REFER TO TYPICAL APARTMENT LOAD CENTER SCHEDULE ON DRAWING E4.2 FOR CIRCUITING INFORMATION. 5. REFER TO MECHANICAL DRAWINGS FOR HVAC UNITS EXACT LOCATION AND ELECTRICAL INFO. 6. EXTERIOR BATHROOMS SHALL HAVE ELECTRIC BASEBOARD HEATER. REFER TO HVAC FLOOR PLANS FOR LOCATIONS. KEYED NOTES: fLc up I 21 te LAUN A 12 M7 la la LC CONNECT VANITY LIGHT AHEAD OF GFCI RECEPTACLE. RECEPTACLE FOR WASHER WATER LEAK SENSOR AND DRYER BOOSTER FAN IF REQUIRED. THE RECEPTACLE SHALL BE MOUNTED 48'' AFF. FIELD COORDINATE EXACT RECEPTACLE PLACEMENT BASED ON WATER LEAK SENSOR LOCATION. KITCHEN UNDERCABINET PUCK LIGHTS 'U' EXACT QUANTITY AND LOCATION SHALL BE COORDINATED WITH ARCHITECT PRIOR TO ROUGHING. ELECTRICAL NOTES FOR HANDICAPPED UNIT (IF APPLICABLE): 1. ALL LIGHTING SWITCHES SHALL BE DECORA RESIDENTIAL GRADE ROCKET TYPE AND BE MOUNTED AT 40" AFF. 2. ALL OUTLETS AND WALL SWITCHES SHALL BE MOUNTED AT LEAST 1 5" FROM ANY CORNER. 3. ALL OUTLETS AND SWITCHES SHALL BE MOUNTED NO HIGHER THAN 48''AFF AND NO LOWER THAN 15"AFF. 4. KITCHEN HOOD REQUIRE SECOND CONTROL MOUNTED AT COUNTER LEVEL. 5. LOAD CENTER MOUNTING HEIGHT SHALL BE THAT HANDLE OF THE TOP CIRCUIT BREAKER NO HIGHER THAN 48" AFF. 6. ALL MINI -HORNS AND STROBES IN HANDICAPPED/HEARING IMPAIRED UNITS SHALL BE MOUNTED AT 24" BELOW CEILING OR ELECTRICAL INSTALLER IS RESPONSIBLE FOR PROVIDING 1 77cd LIGHTS. 42"AFF 12 m62 15 al al al al al al al al ▪ al III al DATA METER 12 17 BEDROOM 012 19 la la al al T w/BA 19 Qt IN 3Q 17 la la 17 12 CO\Y PLAY BEDROOM vp db 17 EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ,-;-,ALL RIGHTS RESERVED tJ CL CC Ew a) a) a) PROGRESS SET SCALE: 0 SALEM, MASSACHUSETTS 01970 UILDINC PEWIT CET 246 Walnut Street MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: OF Ati ADAM DAVIDSON ELECTRICAL NO. 50519 • DRAWING #: • co O - CO CZ co c • co 0 rn 111 2.1 ©TISE DESIGN ASSOCIATES, INC 2019 FEEDER TAG 60AL 60*AL 70AL 70*AL 100AL h 00*AL 125AL 125*AL 150AL 150*AL 175AL 11 75*AL 200AL 200*AL 225AL 225*AL 250AL 250*AL 300AL j300*AL 350AL 1350*AL 400AL 400*AL 500AL 500*AL 600AL 600*AL 800AL 800*AL 1000AL 000*4 1200AL 200*4 NOTES: * DESIGNATES FEEDER WITHOUT NEUTRAL CONDUCTOR SCHEDULE OF FEEDER SIZES ALUMINUM CONDUCTORS NOMINAL AMPERE RATING 60A 70A 100A 125A 150A 175A 200A 225A 250A 300A 350A 400A 500A 600A 800A 1000A 1200A FEEDER CIRCUIT CONDUCTORS FEEDER CIRCUIT CONDUCTORS (3-PH, 3-WIRE + GROUND) (3-PH, 4-WIRE + GROUND) 3#3 & 1#8G 3#2/O & 1#4G rr 11111111mP •.fir111111 3#3/0 & 1#4G 3#4/0 & 1#4G 3#250kcmil & 1#4G 3#300kcmil & 1#2G 3#350kcmil & 1 #2G 3#500kcmil & 1#2G 2 sets 3#4/0 & 1#1G 2 sets 3#250kcmil & 1#1G 2sets 3#350kcmil & 1#1/OG 2sets 3#500kcmil & 1 #2/OG 3sets 3#400kcmil & 1 #3/OG 4sets 3#400kcmil & 1 #4/OG 4sets 3#500kcmil & RMC RISER MC CABLE GRADE LEVEL 2-5" PRIMARY SERVICE CONDUIT DUCTBANK 1 #250kcmilG PAD MOUNT TRANSFORMER 4#3 & 1#8G 4#2/0 & 1#4G 4#3/0 & 1#4G 4#4/0 & 1#4G 4#250kcmil & 1 #4G 4#300kcmil & 1 #2G 4#350kcmil & 1 #2G 4#500kcmil & 1 #2G 2 sets 4#4/0 & 1#1G 2 sets 4#250kcmil & 1#1G 2sets 4#350kcmil & 1#1/OG 2sets 3#500kcmil & 1 #2/OG 3sets 4#400kcmil & 1 #3/OG 4sets 4#400kcmil & 1 #4/OG 1000kVA O 13.2KV-208/120V r 4sets 4#500kcmil & 1 #250kcmilG - SECONDARY SERVICE CONDUIT DUCTBANK 8 SETS (4#500KCMIL, 4"C.) CONDUIT 1/4"C 1/4"C 1/2"C 1/2"C 2"C 2"C 2"C 2"C 2"C 2 1/2"C 2 1/2"C 2 1/2"C 2 1/2"C 3"C 3"C 3"C 3"C 3"C 3 1/2"C 4"C (2)-2 1/2"C (2)-2 1/2"C (2)-2 1/2"C (2)-3"C (2)-3"C (2)-3"C (2)-3 1/2"C (2)-4"C (3)-3"C (3)-3"C (4)-3"C (4)-3"C (4)-3 1/2"C (4)-4"C MAIN ELEC ROOM PULL BOX • ONE -LINE DIAGRAM SYMBOLS H SPD AFR Cb FRAME TRIP LSIG GROUNDING ELECTRODE SYSTEM CURRENT TRANSFORMER SURGE PROTECTIVE DEVICE ARC FAULT REDUCTION SWITCH MOLDED CASE CIRCUIT BREAKER: »S» - INDICATES LONG TIME DELAY - INDICATES SHORT TIME DELAY - INDICATES INSTANTANEOUS PICKUP - INDICATES GROUND FAULT PICKUP UTILITY METER SOCKET. PROVIDE 1-1/2" CONDUIT WITH PULL STRING RETAIL #1 1-1/2" CONDUIT WITH PULL STRING. TYPICAL. MAIN SWITCHBOARD 'MSB': 3000A MCB, 208Y/120 VOLT, 3 PHASE, 4 WIRE, 65kAIC, FULLY RATED 3000AF l S P D 250kAHlt 3000AT Jo LSI AFR 0 n I600ALIRMCI 600A CT's 600AF 600AT • • GND 3000A REFER TO GROUNDING SYSTEM DAIGRAM ON SHEET E3.3 RISER DIAGRAM KEY NOTES: 0 0 0 0 0 0 0 0 STUB -UP CONDUIT AND PROVIDE AT LEAST 25 LINEAR FEET OF CONDUCTORS FOR FUTURE CONNECTION UNDER TENANT FIT -OUT SCOPE OF WORK. COORDINATE STUB -UP LOCATIONS WITH OWNER/ARCHITECT. REFER TO ELEVATOR DETAILS ON SHEET E3.3 FOR CIRCUIT BREAKER, FUSED DISCONNECT AND ELEVATOR FEEDER SIZES. REFER TO CIVIL DRAWINGS FOR EXACT TRANSFORMER LOCATION. REFER TO TRANSFORMER DETAILS ON SHEET E3.3. RELAY LIGHTING CONTROL PANEL WITH ASTRONOMIC TIME CLOCK FOR EXTERIOR LIGHTING CONTROL. PROVIDE ACUTY CONTROLS BLUE BOX LTD WITH FOUR (4) 120V 20AMP RELAYS OR APPROVED EQUAL. KWH SUB -METER. PROVIDE E-MON CLASS 2000 METER 120/280V, 3-PHASE, 200AMP E20-208200-JKIT OR APPROVED EQUAL. SINGLE-PHASE PANEL "HP2" SHALL FEED ALL LIGHTING AND POWER BRANCH CIRCUITS WITHIN COMMUNITY RM, FITNESS CENTER, RESTROOMS AND EXTERIOR DECK ON SECOND FLOOR. 2-ZONES TIME SWITCH WITH ASTRONOMIC TIME CLOCK FOR ROOF LIGHTING 'RB-5' CONTROL. PROVIDE TORK DGLC200A-NC IN NEMA-1 ENCLOSURE OR APPROVED EQUAL. FOR FEEDER CABLE LENGTHS THAT EXCEED 150 FEET, THE FEEDER SHALL BE INCREASED IN SIZE TO COMPENSATE FOR THE VOLTAGE DROP AS REQUIRED BY THE NEC. RISER DIAGRAM GENERAL NOTES: 1. VERIFY AVAILABLE SHORT CIRCUIT CURRENT FOR THE MAIN SERVICE WITH LOCAL UTILITY COMPANY. THE ENTIRE ELECTRICAL DISTRIBUTION SYSTEM SHALL BE RATED FOR THE AVAILABLE SHORT CIRCUIT CURRENT OR AS NOTED ON THE DRAWINGS. 2. ELECTRICAL CONTRACTOR SHALL ENSURE THAT ELECTRICAL INSTALLATION ADHERES TO ALL REQUIREMENTS OF NATIONAL GRID. 3. IF ALUMINUM CONDUCTORS ARE USED IN LIEU OF COOPER, CONTRACTOR SHALL UPSIZE CONDUCTORS AS REQUIRED BY NEC. LSI SPARE 400AF COMMUNITY RM FITNESS i IRMCI500ALI IRMCI500ALI 400AF 400AT HP2 0 IRMCI100*Au SPARE 400AF l 400AF 400AT STANDBY GENERATOR KEYED NOTES: TC 0 ELEC ROOM HPR IRMCI175ALI ELEC CLOSET ELEC CLOSET ELEC CLOSET ELEC CLOSET ELEC CLOSET G5 II ;f MCI150ALITh GPR ATS1 � I15OALI-� i • r IRMCI400ALI IRMCI400ALI IRMCI400ALI 400AF l 400AF l 400AF l 400AT ,) 400AT ,) 400AT � / 150ALI-N I -m MB6 400A 000000 TERMINAL BOX 000000 42kAIC 0605 MB5 r r l I I l Deoeoe a0o0o0 400A 060000 TERMINAL - BOX 0e00 42kAIC 0605 MB4 r l I I • 000000 a0o0o0 400A 000000 TERMINAL - BOX 000O 42kAIC 0000 1 MB3 0e0e0e 000000 400A 060006 TERMINAL - BOX 0000 42kAIC 0®0® MB2 0e0e0e 400A oeueo0 TERMINAL BOX 000000 42kAIC 0000 -- ELEVATOR LOBBY r I120 )AL 1200A CT's 1200AF 1200AT LSI AFR ELEVATOR #1 • ELEVATOR MACHINE ROOM 0 ELEVATOR #2 METERBANK 'MB6' TO CONSIST OF 400A MLO, 208Y/120V, 30, 4W, 42kAIC MAIN TERMINAL BOX AND STACK MODULES WITH (11) 125A, 10, 3W METER SOCKETS AND RESPECTIVE 2-POLE, 100A CB's. METERBANK 'MB5' TO CONSIST OF 400A MLO, 208Y/120V, 30, 4W, 42kAIC MAIN TERMINAL BOX AND STACK MODULES WITH (13) 125A, 10, 3W METER SOCKETS AND RESPECTIVE 2-POLE, 100A CB's. METERBANK 'MB4' TO CONSIST OF 400A MLO, 208Y/120V, 30, 4W, 42kAIC MAIN TERMINAL BOX AND STACK MODULES WITH (13) 125A, 10, 3W METER SOCKETS AND RESPECTIVE 2-POLE, 100A CB's. METERBANK 'MB3' TO CONSIST OF 400A MLO, 208Y/120V, 30, 4W, 42kAIC MAIN TERMINAL BOX AND STACK MODULES WITH (13) 125A, 10, 3W METER SOCKETS AND RESPECTIVE 2-POLE, 100A CB's. POWER RISER DIAGRAM NOT TO SCALE METERBANK 'MB2' TO CONSIST OF 400A MLO, 208Y/120V, 30, 4W, 42kAIC MAIN TERMINAL BOX AND STACK MODULES WITH (11) 125A, 10, 3W METER SOCKETS AND RESPECTIVE 2-POLE, 100A CB's. 0 GENERATOR REMOTE ANNUNCIATOR. COORDINATE EXACT LOCATION WITH ARCHITECT. PROVIDE 1" CONDUIT AND WIRING PER MANUFACTURING RECOMMENDATIONS. mm GENERATOR ACCESSORIES IN 2" CONDUIT: BATTERY CHARGER AND BATTERY HEATER, JACKET WATER HEATER. EMERGENCY FUEL SHUT-OFF SWITCH. SHALL BE MOUNTED ON GENERATOR ENCLOSURE IN BREAK GLASS CABINET. PROVIDE GENERATOR START CIRCUIT FROM EACH ATS TO GENERATOR IN 1" CONDUIT. CONDUCTORS SIZE SHALL BE PER MANUFACTURER'S RECOMMENDATIONS. VIBRATION SPRING ISOLATOR. TYPICAL. PROVIDE BONDING OF THE STANDBY GENERATOR PER NEC ARTICLE 250.35(B) AS NON -SEPARATELY DERIVED SYSTEM. PROVIDE GENERATOR WITH INTEGRAL AUTOMATICALLY CONTROLLED MULTIPLE STAGE RESISTOR LOADBANK IN SERIES WITH ENGINE RADIATOR. LOADBANK SHALL BE AT LEAST 75kW AND MADE UP OF FOUR (4) 25% LOAD STEPS. DISTRIBUTION PANELBOARD 1200AMP MLO, 208Y/120V, NAME: DP 30, 4W, 65kAIC CIRCUIT DESCRIPTION OF LOAD 1 ATS-2 (PANEL "GPB") 2 MECHANICAL PANEL "MP" 3 PARKING GARAGE PANEL "PP1" 4 PARKING GARAGE PANEL "PP2" 5 HOUSE PANEL "HPB" 6 ATS-1 (PANEL "GPR") 7 HOUSE ROOF PANEL "HPR" 8 EUH-1A (GARAGE) 9 EUH-1C (GARAGE) 10 EUH-2A (GARAGE) 11 HOUSE 2nd FL. PANEL "HP2" 12 TESLA CHARGER 13 SPARE 14 SPARE 15 SPACE CIRCUIT TRIP 400 400 200 200 225 150 150 3 110 3 110 3 110 3 100 2 100 2 100 2 200 3 BREAKER POLE 3 3 3 3 3 3 NOTES VESTIBULE RGA 1 �f DP 1200A MLO SM1 0 200AL PP1 TO ATS 2 i SM2 0 4" HOUSE KEEPING PAD STAND-BY GENERATOR NOTES: r 150kW/188kVA, 208Y/120 VOLT NATURAL GAS STAND-BY GENERATOR SET W/SOUND ATTENUATED LEVEL-1 ENCLOSURE LOAD BANK 300A 3P NOT SEPARATELY DERIVED SYSTEM 0 3#1 & 1 #6G., ALUMINUM SE CABLE TYPICAL FOR 11 LC-X • - 3#1 & 1 #6G., ALUMINUM SE CABLE TYPICAL FOR 13 LC-X «= 3#1 & 1 #6G., ALUMINUM SE CABLE TYPICAL FOR 13 LC-X • s 3#1 & 1 #6G., ALUMINUM SE CABLE TYPICAL FOR 13 LC-X LC-X 200AL PP2 1. BOTH ELEVATORS SHALL BE CONNECTED VIA STANDBY GENERATOR, BUT ONLY ONE ELEVATOR PER ELEVATOR BANK SHALL OPERATE ON STANDBY GENERATOR POWER SIMULTANEOUSLY. 2. PROVIDE WARNING LABELS AT EACH PANEL SUPPORTED BY STANDBY GENERATOR. THE LABEL SHALL BE PERMANENTLY AFFIXED TO THE PANELS AND SHALL CONTAIN FOLLOWING INFORMATION: WARNING! THIS PANEL IS SUPPORTED BY STAND-BY GENERATOR AUTOMATIC TRANSFER SWITCH SCHEDULE DESIGNATION AMPS POLES ATS1 (LEGALLY REQUIRED) 150 3 ATS2 (OPTIONAL STANDBY) 400 3 VOLTS 208 208 CYCLE RATING 30 30 3#1 & 1#6G., ALUMINUM SE CABLE TYPICAL FOR 11 AIC RATING ENCLOSURE ITEM SERVED SPECIFICATIONS TYPICAL LOAD CENTER "LC" (SEE SCHEDULE ON SHEET E4.2) 1 225AL HPB FROM GENERATOR-IRMCI500ALI LC 0 '400AL • 400AL MP 22kA NEMA 1 ELEVATORS,FA,LTG. ASCO SERIES 300 OPEN TRANSITION OR EQUAL 42kA NEMA 1 HVAC,FA,LTG,MISC. ASCO SERIES 300 DELAYED TRANSITION OR EQUAL SCHEDULE OF PANELBOARDS PANEL VOLTAGE PHASE WIRE MCB HPB 208Y/120V 3 4 HPR 208Y/120V 3 4 PP1 208Y/120V 3 4 PP2 208Y/120V 3 4 GPR 208Y/120V 3 4 GPB 208Y/120V 3 4 MP 208Y/120V 3 4 HP2 120/208V 1 3 NOTES: 1. REFER TO SHEET E4.2 FOR FULL 150A 150A 400A 100A/2P PANELBOARDS M LO 225 225 225 400 AIC 42K 22K 42K 42K 22K 42K 42K 22K SCHEDULES. TOTAL MOUNTING POLES 42 42 42 42 42 42 60 24 SURFACE SURFACE SURFACE SURFACE SURFACE SURFACE SURFACE RECESSED 0 G2 GPR: 20A/1 P �� G3 GPR:20A/2P • 0 ATS2 • 400AL GPB J ROOF SIXTH LEVEL FIFTH LEVEL FOURTH LEVEL THIRD LEVEL SECOND LEVEL FIRST LEVEL E BASEMENT EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED Project #: 4017 w cn O cL CL CC ArchitectureSite Planning Project Management PROGRESS SET co N u U F SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 246 Walnut Street MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: a Ili OF Ati ADAM DAVIDSON ELECTRICAL NO. 50519 o TEa� ftioNAL so`' DRAWING #: 9- CO CO CO 1.0 1` CO CO CO CO ti co NTS ELECTRICAL cn H3.1 ©TISE DESIGN ASSOCIATES, INC 2019 CHASE 3 3 (2) 4"C. 0 6_ (2) 4"C - 6_ (2) 4»C - (2) 4"C. (2) 4"C. 6_ 6_ r(2) 4"C. �6H 3 3 3 3 3 3 TO MAIN ELECTRICAL ROOM GROUNDING SERVICE #6AWG COOPER GROUND WIRE. TELECOMMUNICATION SERVICE GROUND BUS. (TYPICAL) 6_ 6_ 6_ 6_ 6_ 6_ 6_ 6_ 6_ a 6_ 46:161[61[61 46][61[61161Hrd rOTOTOTOTOTOTO1 MMMMMMM TENANT MEDIA PANEL TYPICAL FOR ALL ROOF ROOF SIXTH LEVEL FIFTH LEVEL FOURTH LEVEL THIRD LEVEL SECOND LEVEL FIRST LEVEL (3) 4"C. MAIN TELECOMMUNICATION BOARD BASEMENT T H,'L H,'COMMUNICA TIONS RIS H,'R DI/ GRAM t SEE NOTE-2 1 e SEE NOTE-1 NOTES: LEVITON — 47606—BNP OR APPROVED EQUAL. MOUNT INSIDE MEDIA ENCLOSURE LEVITON 47605-21 E WITH FLUSH COVER 47605-21C i (1) CAT5E TO EACH PHONE OUTLET TYPICAL FOR 11 r IC TYPICAL FOR 13 I IC TYPICAL FOR 13 CORRIDOR ABOVE CEILING SPACE CORRIDOR ABOVE CEILING SPACE CORRIDOR ABOVE CEILING SPACE ( CORRIDOR ABOVE CEILING SPACE TYPICAL FOR 13 I IC TYPICAL FOR 11 APARTMENT UNIT INTERCOM STATION LOCATED INSIDE EACH APARTMENT ENTRY AREA. AS SHOWN IS MANUFACTURED BY "AIPHONE" CAT # GT-1M—L CORRIDOR ABOVE CEILING SPACE TELECOM ROOM GPB:#14 INTERCOM CONTROL PANEL LOCATED INSIDE THE TEL/DATA CLOSET. AS SHOWN IS MANUFACTURED BY AIPHONE CAT# (2)GT—VBX, GT—BCX, (2)GT—BC, (3)PS-24200UL NOTES: 1. THE SYSTEM DESIGN IS BASED ON THE AIPHONE GT—SERIES MULTI FAMILY SYSTEM WITH VIDEO ENTRY. 2. ALL WIRING TYPES, POWER SUPPLIES, AUDIO AND VIDEO COMPONENTS SHALL BE PER THE MANUFACTURER SPECIFICATIONS. MAIN ENTRY VESTIBULE GPB:#12 MAIN INTERCOM PANEL. AS SHOWN IS MANUFACTURED BY "AIPHONE" CAT # GT—DM. LOCATED AT ENTRY VESTIBULE. IC MAIN INTERCOM CONTROL UNIT IC MAIN INTERCOM PANEL 0 3. PROVIDE ALL COMPONENTS REQUIRED FOR COMPLETE VIDEO INTERCOM SYSTEM. P P P SIXTH LEVEL FIFTH LEVEL FOURTH LEVEL THIRD LEVEL SECOND LEVEL FIRST LEVEL TV TV TV TYPICAL/T H,'NANT UNIT INT H,'RCOM S YST H,'M WIRING DIAGRAM y y —(1) RG-6 TO EACH TV OUTLET 1. ELECTRICAL INSTALLER SHALL PROVIDE ONE POWER RECEPTACLE IN THE BOTTOM OF THE MEDIA PANEL. WIRE AS INDICATED ON THE FLOOR PLANS. 2. PROVIDE ONE CAT-5E CABLE AND ONE RG-6 CABLE FROM BUILDING TELECOMMUNICATION CLOSET/BOARD TO EACH APARTMENT MEDIA PANEL. LEAVE AT LEAST 4 FEET SLACK AT BOTH ENDS FOR FUTURE TERMINATION. DWH,'LLING Mk,'DIA PANH,'L (MP) WIRING DIAGRAM E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED Li Project #: 4017 w F ArchitectureSite Planning Project Management PROGRESS SET CO C\J UILDINC PERMIT GET 246 Walnut Street SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: jKO�� �'� sic ADAM yc DAVIDSON ELECTRICAL-4 NO. 50519 • 'mot DRAWING #: co N O U) d) N U U) U) 2 a) O a) z x Cu CO CO CO1.0 CO CO CO IC) I` O NTS DIAGRAMS z W z 0 H 0 0 ELECTRICAL 2 ❑ ©TISE DESIGN ASSOCIATES, INC 2019 ELEVATOR SCHEDULE GENERAL NOTES: 1. SEE ELEVATOR DETAILS. 2. PROVIDE BRANCH CIRCUIT FROM ELEVATOR FUSED DISCONNECT SWITCH TO ELEVATOR CONTROLLER, SAME AS CONTROLLER BRANCH CIRCUIT SIZE LISTED BELOW. 3. TERMINATE EACH 20 AMP HOMERUN IN A 30 AMP SAFETY SWITCH LOCATED IN THE ELEVATOR CLOSET. 4. PROVIDE A LOCKING CLIP ON EACH BRANCH CIRCUIT BREAKER. ITEM # ELEV-1 ELEV-2 ITEM # HP FLA VOLTS CB PANEL SIZE NAME 11 34 208 11 34 208 CKT#1 CLOSET LIGHTING & POWER HOMERUN ELEV-1 ,2 GPR-20A/1 P NOTES: 70A GPR 70A GPR CKT#2 ELEVATOR SHAFT LIGHTING AND REC. HOMERUN GPR-20A/1 P DISCONNECT SWITCH SIZE 60/45A CONTROLLER CIRCUIT CONDUCTORS SIZE 3#6 & 1 # 10G. - 1"C. 60/45A 3#6 & 1 # 10G. - 1"C. CKT#3 CKT#4 ELEVATOR SHAFT ELEVATOR CAB SUMP PUMP LIGHTING & POWER HOMERUN HOMERUN GPR-20A/1P GPR-20A/1 P NOTES A,B A,B NOTES C,D A. PROVIDE CONTROL WIRING FROM STANDBY ATS TO INDICATE POWER STATUS AT EACH ELEVATOR DISCONNECT IN THE MACHINE ROOM. B. ELEVATOR CIRCUIT BREAKER, FEEDER SIZE AND DISCONNECT SWITCH FINAL FUSE SELECTION SHALL BE PROVIDED PER ELEVATOR MANUFACTURER'S SHOP DRAWINGS SUBMITTAL AND SPECIFICATIONS. C. PROVIDE 20A LOCKABLE DISCONNECT SWITCHES IN MACHINE ROOM FOR EACH ELEVATOR CAB BRANCH CIRCUIT. D. SUMP PUMP IS OPTIONAL. COORDINATE SUMP PUMP REQUIREMENTS AND LOCATION WITH PLUMBING DRAWINGS. C6> BUILDING STRUCTURAL STEEL KEY NOTES: MACHINE ROOM SMOKE DETECTOR. ELEVATOR ENCLOSED FUSED DISCONNECT SWITCH. LOCATE SWITCH WITHIN 18" FROM THE STRIKE SIDE OF THE MACHINE ROOM DOOR AT 66 AFF. SEE ELEVATOR SCHEDULE FOR SIZE OF FUSE, SWITCH AND FEEDER CIRCUIT. REFER TO LIGHTING FIXTURE SCHEDULE FOR MACHINE ROOM LIGHT FIXTURE SPECIFICATION. FOR LIGHT FIXTURE 'F2' PROVIDE FLUORESCENT LIGHTING FIXTURE LISTED FOR WET LOCATIONS AS LURALINE I#AVB43-FR-F32TE-TAL OR APPROVED EQUAL. ILLUMINATION SHALL BE NO LESS THAN 1OFC AT PIT FLOOR LEVEL. FIRE ALARM ADDRESSABLE INTERFACE DEVICE (5 TOTAL), AS DEFINED BELOW SHALL BE LABELED AND TERMINATED IN JUNCTION BOX FOR CONNECTION TO CONTROLLER. A. SIGNAL AT DESIGNATED LANDING B. SIGNAL AT ALL OTHER FLOOR LANDINGS C. SIGNAL AT THE TOP OF THE ELEVATOR SHAFT D. SIGNAL AT THE MACHINE ROOM E. SIGNAL FOR ACTIVATION OF MOTORIZED DAMPERS SMOKE DAMPER AND FIRE ALARM ADDRESSABLE INTERFACE DEVICE WHERE SHOWN ON PLANS. ADDRESSABLE INTERFACE DEVICE. LOCATE IN AREA IN FRONT OF ELEVATOR CAB. 1 #2 INSULATED COPPER IN 3/4"C. 1 #2 INSULATED COPPER IN 3/4"C. 1 #2 INSULATED COPPER IN 3/4"C. 1 #4 INSULATED COPPER IN 3/4"C. CABLE TV PHONE&DATA SERVICE 1#10 JUMPER TYPICAL. 1#4/0 BARE COPPER IN 1" PVC 3/4"dia. x 10ft LONG COPPERWELD GROUND ROD ELECTRIC ROOM GB � 0 _L ELECTRIC CLOSET ELECTRIC CLOSET ELECTRIC CLOSET GB il® GB IMC SLEEVE THROUGH SLAB GENERAL NOTES: ELECTRIC CLOSET ELECTRIC CLOSET ID 1 #4/0 INSULATED COPPER IN 1"C. GROUNDING BUSHING. TYPICAL. 1 #2/0 INSULATED COPPER IN 1 "C. 1. WHETHER OR NOT INDICATED ON THIS GROUNDING RISER, ENTIRE GROUNDING SYSTEM SHALL COMPLY WITH NEC 2017 AND ALL AUTHORITIES HAVING JURISDICTION. 0 KEY NOTES: 0 0 0 0 0 0 MAIN ELECTRIC ROOM GROUND BUS 1 1 TrSERVICE ENTRANCE ELECTRICAL EQUIPMENT 208Y/120V NEUTRAL BUS MAIN BONDING JUMPER DEVICE RACEWAY BONDING 1"C. TO MAIN COMMUNICATION ROOM CKT#3 c)GF WP BOTTOM OF SD O5 HOISTWAY CM (PIT) CKT#2 F2 CORRIDOR \ CM LOWEST FLOOR WE WP CKT#4 W �! - LSo LS "69 CM n CM CM )CKT#1 WP BRANCH CIRCUIT DISCONNECT SWITCHES. QUANTITY AS REQUIRED. ELEVATOR MACHINE ROOM NOT TO SCALE ELEVATOR CAB CORRIDOR TYPICAL FLOOR ELEVATOR HOISTWAY PARTIAL PLANS NOT TO SCALE NOTES: 1. SEE FLOOR PLANS FOR EXACT CONFIGURATION OF HOISTWAY. 2. INSTALLATION MUST BE PER 524 CMR. ROOF 6th FLOOR 5th FLOOR 4th FLOOR 3rd FLOOR 2nd FLOOR BASEMENT MAIN GROUND BUS - 1 /4" x 4" x 20"L. COPPER MOUNTED TO WALL WITH INSULATING BRACKETS. EXOTHERMIC WELD CONNECTION. TYPICAL. WATER SERVICE AT STREET SIDE OF WATER METER. UNDERGROUND METAL WATER PIPE GREATER THAN 10 FEET LONG. GROUNDING CLAMP WITHIN 5 FEET OF ENTRANCE POINT OF PIPE. INSTALL BONDING JUMPER FROM GROUND BUSHING TO GROUND BUS SIZED PER NEC 2017 SECTION 250.122 TELECOMMUNICATIONS GROUND BUS - 1/4" x 2" x 14"L. COPPER MOUNTED TO WALL WITH INSULATING BRACKETS. GOU\31\G SYSTEV NOT TO SCALE 3 AGA V E L E VAT O DOWN TO CKT#2 F2 TOP OF HOISTWAY SD 0 CM CORRIDOR \-/ CM TOP FLOOR DETAILS 1/4" THICK x 4" WIDE x 20" LONG - COPPER GROUND BAR SEE NOTE-1 1/4"\ 7/16" HOLE - (TYPICAL) SEE NOTE-2 I CDm m m m m m m m m m m m m m m m m m m m 2" 20" DETAIL NOTES: ELEVATOR FUSED DISCONNECT SWITCH IN ELEVATOR CLOSET GPR t POWER WIRING IN RACEWAY. SEE ELEVATOR SCHEDULE. ELEVATOR CONTROLLER /- ` EMERGENCY TRANSFER, RE -TRANSFER AND DELAY TRANSFER SIGNAL FROM ATS-1 IN 1"C. CONTROL WIRING CONNECTED TO OTHER CONTROLLERS IN 1 "C. ELEVATOR POWER SHUT-OFF DIAGRA ELEVATOR MACHINE ROOM NOTES: NOT TO SCALE ADDRESSABLE INTERFACE DEVICES PROGRAMMED AND CONNECTED TO THE ELEVATOR CONTROLLER AND ADRESSABLE LOOP ELEVATOR HOISTWAY ELEVATOR PIT ELEVATOR LOBBY ELEVATOR LOBBY ELEVATOR LOBBY CI' F OCR TYPICAL FLOOR LOWEST FLOOR TYPICAL ADDRESSABLE TYPE SMOKE DETECTOR CONNECTED TO ADDRESSABLE LOOP ELEVATOR RECALL DETAIL NOT TO SCALE 1. PROVIDE "ELEVATOR" FUNCTION SWITCH IN MAIN FACP TO ALLOW ANY SMOKE DETECTOR SHOWN ON THIS DETAIL TO FUNCTION WITHOUT NOTIFICATION OF BUILDING ALARM SYSTEM. 2. PROGRAM THE FOLLOWING TOGETHER: A. ELEVATOR CLOSET DETECTORS B. DESIGNATED FLOOR DETECTOR C. ALL OTHER DETECTORS SHOWN ON THIS DETAIL 1. COPPER GROUND BAR SHALL BE MOUNTED TO WALL WITH NEOPRENE INSULATORS PROVIDED AS PART OF A COMPLETE GROUND BAR ASSEMBLY. GROUND BAR SHALL BE ERICO / ERITECH EGBA1 4420CC, OR APPROVED EQUAL. DUCT MOUNTED SMOKE DETECTOR HOUSING, DUCT DETECTOR AND CONTROLS FIRE ALARM MOUNTED 2. CONDUCTORS SCHEDULED TO CONNECT TO ELECTRIC SERVICE GROUNDING ELECTRODES SHALL BE CONNECTED TO GROUND BAR VIA EXOTHERMIC WELD. GROUND BAR DETAIL MECHANICAL EQUIPMENT (ROOF -TOP UNIT) PITCH POCKET SEE NOTE-2 SEE NOTES 4 & 5 SEE NOTE-1 ROOF CURB ROOF LEVEL SEE FLOOR PLANS FOR BRANCH CIRCUIT HOMERUN, SEE NOTE-3 ROOF TOP EQUIPMENT LIGHTING & NOT TO SCALE RTS INTEGRAL SUPERVISED UL LISTED RELAY FOR C-TYPE WITH 1 0A©1 20V CONTACT WITH 24V DC COIL + SIGNAL FROM DUCT 24 0 iNC SMOKE DETECTOR Duel of \ /. INCOMING POWER 120V-10 s WALL NORMAL/EMERGENCY POWER STATUS FROM LEGALLY REQUIRED ATS-1 IN 1"C. I I I I NO\COv 3ASTIBLE BUILDING WALL 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3'-0 • 5'-0" 10'-0" IF PLACED IN FRONT OF WINDOW, DOOR OR VENTILATING DUCT BOUNDARY OF CLEAR AREA • PROTECTIVE VEHICLE POSTS STEEL, CONCRETE FILLED BOLLARDS BY G.C. CONCRETE PAD \ATIO\AL GRID TRANSFORIv E� A FRONT • TRAVELED WAY 10'-0" 6'-0" I I • • PAD MOUNTED TRANSFORMER LOCATION TO BUILDINGS AND ROADWAYS NOTE: ALL FSD LOCATIONS INDICATED ON THE DRAWINGS SHALL BE PROVIDED WITH THE COMPONENTS SHOWN. THE LOCATION OF THE REMOTE TEST STATION SHALL BE COORDINATED WITH LOCAL FD PRIOR TO ROUGH -IN DAMPER ACTUATOR POWER WIRING INCOMING 120V-1 0 POWER NEUTRAL NEUTRAL RELAY: NORMALLY CLOSED CONTACT TO OPEN THE CONTACT AND CLOSE DAMPER UPON ACTIVATION OF FIRE ALARM SIGNAL LINE 1 •I ACTUATOR TERMINALS DUCT IVOU\TED SMO'CE DETECTOR WITH DAMPER CO\TROL DETAIL NOTES: 1. PROVIDE GFCI DUPLEX RECEPTACLE AND LIGHTING TOGGLE -SWITCH IN 2-GANG WEATHERPROOF OUTLET BOX. PROVIDE OUTLET BOX WITH DEVICE COVER RATED FOR WET -IN -USE APPLICATIONS. MOUNT DEVICES APPROXIMATELY 24" ABOVE FINISHED ROOF. 2. PROVIDE GALVANIZED STEEL CHANNEL AT MECHANICAL EQUIPMENT TO FACILITATE MOUNTING LIGHTING AND DEVICES. ATTACHMENT TO MECHANICAL EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 3. INTERIOR PORTION OF BRANCH CIRCUIT SHALL BE EMT. EXTERIOR PORTION OF BRANCH CIRCUIT SHALL BE RGS. TRANSITION FROM EMT TO RGS SHALL OCCUR IN THE BUILDING. 4. PROVIDE FLUORESCENT LIGHTING FIXTURE LISTED FOR WET LOCATIONS AS LURALINE #AVB43-FR-F32TE-TAL. COORDINATE LOCATION OF LIGHTING FIXTURE WITH MECHANICAL EQUIPMENT TO ENSURE OPTIMUM ILLUMINATION AT DISCONNECT SWITCH AND EQUIPMENT ACCESS DOORS. 5. COORDINATE EXACT MOUNTING HEIGHT WITH SPECIFIC MECHANICAL EQUIPMENT. DESIGN INTENT: LIGHTING FIXTURE SHALL EXTEND APPROXIMATELY 12" ABOVE MECHANICAL EQUIPMENT. RECEPTACLE MOUNTING CLEAN FILL Scale: Not To Scale A A 60" MIN. SEE NOTE-2 8'-9„ �I I"ITI'III' II I I I -Ili= 3„1 DETAIL NOTES: 13. 1 8" DIAMETER CONCRETE FOOTING CONCRETE CROWN, PRIMED AND PAINTED TO MATCH BOLLARD 5 -0" MAX >- LLJ H- 6" DIAMETER GALVANIZED STEEL PIPE (SCHEDULE 40) FILLED WITH CONCRETE, PRIMED AND PAINTED YELLOW, SEE NOTE-1 FINISHED GRADE I';'IIII IIIIIIIIII IIII IIII IIIII IIIII IIIII IIIIIIIIIII Ii -I MI = = 1-III-1 14" - #2/0 AWG BARE COPPER CONDUCTOR, SEE NOTE-3 1. TRAFFIC PROTECTION BOLLARDS RERQUIRED AT UTILITY COMPANY DISTRIBUTION EQUIPMENT, (e.g. PAD -MOUNTED TRANSFORMER, PRIMARY SWITCH, etc.), SHALL BE PROVIDED IN ACCORDANCE WITH THE LATEST APPLICABLE UTILITY COMPANY CONSTRUCTION STANDARDS. a) CONTRACTOR SHALL EXERCISE CAUTION TO AVOID INTERFERENCE WITH GROUND GRID CONDUCTORS AND/OR ADJACENT CONDUITS. 2. COORDINATE EXACT HEIGHT EXTENSION AFG WITH THE APPLICABLE UTILITY COMPANY. 3. CONNECT TO PAD -MOUNTED TRANSFORMER GROUND GRID WHERE APPLICABLE. FINISHED OR ASPHALT I- III -III-I II -III - III =I I =III -III- =III=111� -111-III--111-11II 91H11= 11911911- / I I 26" TRAFFIC PROTECT ON BOLLARD NOT TO SCALE g,- =III=III= =III=III=111 ILL a 36" MIN. Lll 1_ II II III III i1 I 6„ UNDERGROU PRIV PLASTIC SPACERS 6" J� J( 6„ / - SAND FILLED ENVELOPE \D DETAIL AY NOT TO SCALE CLEAN FILL FINISHED GRADE IIII-I I I -I I HI I=I I I -III-III-I 1I- -111-1 II_ III III III 1E III I IL_,III SAND FILLED 3" II- 24" MIN. CONCRETE ENVELOPE TYPICAL UNDERGROU\D DETAIL SECONDARY NOT TO SCALE E E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED Li Project #: 4017 w cn cL CC 0 w F ArchitectureSite Planning Project Management PROGRESS SET CO N u CD F- SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 246 Walnut Street MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: OF Abq ADAM t DAVIDSON m g ELECTRICAL - NO. 50519 / o TERM ft►ot4AL E4 DRAWING #: 303 1_11 Cu CO CO COCO LO CO CO LOC) NTS ©TISE DESIGN ASSOCIATES, INC 2019 NAME C1 C2 C3 C4 C5 CM1 CM2 Item Recessed Cow Lighting Recessed Cow Lighting Recessed Cow Lighting Recessed Cow Lighting Recessed Cow Lighting Ceiling Mount Ceiling Mount CM3 Ceiling Mount CM4 Recessed Wall Washer P1a Pendant P1b Pendant P2 Pendant P3 P4 R1 R2 R3 VL1 RC-2 RC-3 RB-1 RB-2 RB-3 RB-4 Pendant Pendant Recessed Downlight Recessed Downlight Recessed Wall Washer Electric Mirror 2500 to 3000 Lumen 4" Downlight 1500 Lumen Lensed Downlight 4" Room Name Typ Unit Entries in Corridors First Floor Elevator Lobby First Floor Lobby - Focal Wall Community Room (at banquette seating area) Community Room (Kitchen back wall) Upper Floor Elevator Lobbies Manufacturer TBD Pinnacle Pinnacle Pinnacle Pinnacle Eureka Restrooms WAC Lighting Co. Fitness Room Community Room 2nd Level Mezzanine Open below to Lobby 2nd Level Mezzanine Open below to Lobby Zaneen Cooper Petite Friture Petite Friture Lobby (above Hubbarton Forge Concierge Desk) Mail Room Sonneman Community Room Hubbarton Forge Throughout Amenity Spaces and Common areas (including corridors) Accent areas within Amenity Spaces and Common areas Lobby, Fitness Room, Community Room Restrooms/ Corridor Lithonia Lithonia Juno Electric Mirror Linear LED Strip (Backlight Display Window Ecosense Lighting Glass) Linear LED Strip (Built in Pocket) Under Bench LED Strip OP1 Canopy LED Strip OP2 Small Class Downlight 2" RB-5 Canopy Uplight LED Strip SW-1 SW-2 SW-3 SW-4 Decorative Entry Sconce (Small) Decorative Entry Sconce (Small) Wall Pack Snail LED Cylinder Linear LEDfor under bench lighting. Roof Canopy BOH/Egress Awnings Prolume Lighting Prolume Lighting Lumenpulse RAB Lighting Acuity Brands Series / Model Number Edge Evolution series Edge Evolution series Edge Evolution series Edge Evolution series SPI N/3036-LED.22.30-DV- WH-WH FM-16622 Glorious 750- Surface Model No: L32905 Halo/SLD606830W H Vertigo Pendant - Large Vertigo Pendant - Small Penumbra Large LED Pendant#139811 Waveforms- Small Bell LED Pendant 2676.25W Cityscape Large LED Pendant L D N6- 3 0-15- L 0 6-A R- L S S- MVOLT-EZI 0-TRW5 LD N4-30-15-L06-AR- LSS- MVOLT-EZI 0-TRW5 6RLA-G2-06LM-30K-90C RI - WFL-120-FRPC-WH Novo TROV L50 Contour Neotour Lumenfacade Horizontal SLI M26Y Incito Cylinder _ G-I- \1G = X-UR=SCE=D Description LED Linear Recessed- Continuous Wall Grazing Light. Typical Length 5'-0". Electrician to V.I.F. fixture length. LED Linear Recessed- Continuous Wall Grazing Light. 13'-0" L. Electrician to V.I.F. fixture length. LED Linear Recessed- Continuous Wall Grazing Light, approx. 19'-8" overall length. Electrician to V.I.F. fixture length. LED Linear Recessed- Continuous Wall Grazing Light. Lengths vary; one side approx. 7'-6 " L and the other is approx 9'-3". Electrician to V.I.F. fixture length. LED Linear Recessed- Continuous Wall Grazing Light, approx. 12'-5" L. Electrician to V.I.F. fixture length. Spin Ceiling Mount Dimensions: 19.7" diameter x 4"H Light Source: 22W, LED 3000K (WARM) Voltage: TBD Dimming Option: 0-10V DIMMING (120-277V) Structure Finish: White Decorative Plate Finish: White Planets LED Surface Mount Dimensions: 22" dia. x 2"H Lamp: LED Voltage: 120V Color temp: 3500K Finish: extruded aluminum trim with silk screen glass diffuser Glorious 750 Surface Mounted. Color: 3000K. CRI: >80. Fixture Finish: 03 Crystal White. Diffuser: OpaVMicro-prism. Lamp: LED. 120V. Dimensions: 29.5" Dia. x 4.75" H. Dimensions: 6" Dia x 2" H (housing) Lamp type: LED Finish: White Pendant fixture with fiberglass structure stretched with polyurethane ribbons. One 75 watt 120 volt A19 medium base incandescent bulb is required, but fixture to be wired for LED bulb. Large: 78.75 inch width x 6.7 inch height x 124 inch maximum length. Finish: Black. Pendants to be installed at varying heights V.I.F. Pendant fixture with fiberglass structure stretched with polyurethane ribbons. One 75 watt 120 volt A19 medium base incandescent bulb is required, but fixture to be wired for LED bulb. Small: 55.1 inch width x 5.9 inch height x 123 inch maximum length. Finish: Black. Pendants to be installed at varying heights V.I.F. LED Lamping: 22 Watts, CCT:300K, CRI: 90, Input:120-277 Vac, Dimming: Line Voltage, LED Source Lumens: 1900, Dimensions: 56"L x 3.3"W x 18.7"H x 30"- 100"OH, Canopy - 7.3" OD, Finish: Burnished Steel 08 with Accent Finish: Dark Smoke 07. Bottom of fixture to be installed 6'-6" A.F.F. Bulb Type: Integral LED, Bulb Quanity: 1 and included, Wattage: 21, Initial Lumens: 1900, Input Voltage: 120VAC, CCT: 3000k, CRI:90. Dimensions: 14' Dia. x 15"H, Canopy 4.5"W, Hanging Details: 6' Adjustable Cord, Shade: Satin Black w/ White Interior. Bottom of fixture to be installed at 8'-0" A.F.F. LED Lamping: 57 Watts, CCT:2700K, CRI: 90, Input:100-120Vac, Dimming: Line Voltage, LED Source Lumens: 5700, Dimensions: 59.90"L x 5.30"W x 15.50"H x 39.60"OH, Canopy - 5.3"x14.8", Finish: Burnished Steel 08 with Accent Finish: Vintage Platinum 82 6" Round downlight Color temp: 3000K Trim Color: White Finish: Semi-specular Voltage: Mufti -volt 4" Round downlight Color temp: 3000K Trim Color: White Finish: Semi-specular Voltage: Mufti -volt 6" Basic Series LED Retrofit Adjustable Trim Color temp: 3000K Distribution: Wide Flood Voltage: 120 Finish: White Now Lighted Mirror Dimensions: 48"W x 36"H Lamping: 2 x T5HO, 39w Specification : #L50-I-XX(Per Plan)-12-30-80-MULT-9x59 Leader Cable : #CBL-3P- L-UNV-10 Jumper Cable : #CBL-3P-L-UNV-01 (As Req'd) Mounting Track and Clips : #MNT- LTRKCLI P-48/MNT-L-TRKCLIP-12(LENGTH PER PLAN) Lamping : LED (Included) Wattage (W) : 12W/FT Output (Im) : 9231m/FT CCT (K) : 3000K CRI : 80 Dimming Protocol : 0-10V Voltage (V) : 120/277V Distribution : 9 x59 LabeVIP : IP54 Finish : Aluminum Specification : #LOGH RO-120/277-LENGTH(Per Plan)-30x60-UMASSI(Verify)-DIM. ETE-3GV Leader Cable : #LOGLC-UL-LENGTH(By EC) -BLACK Jumper Cable : #LOGJC-UL-1-BLACK(As Req'd) Lamping : LED (Included) Wattage (W) : 8.5W/FT Output (Im) : 9641m/FT CCT (K) : 3000K CRI : 80+ Dimming Protocol : 0-10V Voltage (V) : EC to Verify Distribution : 30x60 Label/IP : IP66 Finish : Silver (Verify) Specification : #SLIM-26-Y/D10 Lamping : LED (Included) Wattage (W) : 26W Output (Im) : 35801m CCT (K) : 3000K CRI : 71 Dimming Protocol : 0-10V Voltage (V) : 120-277V Label/IP : IP66 Finish : Bronze Specification : #IC0-30/1D-2AR-LD-50DMVOLT- UGZ-WM-DNA (Verify) Lamping : LED (Integral) Wattage (W) : 10W Output (Im) : 10001m CCT (K) : 3000K CRI :80 Dimming Protocol : 0-10V Voltage (V) : 120-277V Distribution : 50° Finish : Natural Aluminum (Verify) NAME Item Room Name Manufacturer FER-1 PT-1 RW-1 ....................... G GEM Z LS A ........................... B ........................... C .......................... C1 V F ........................... H J K Existing Cobra Head Full cut-off Bollard Recessed Wall Light GARAGE LED SURFACE MOUNT w/MOTION SENSOR GARAGE LED SURFACE MOUNT w/EMERGENCY BACK-UP ................. SMALL EXTERIOR WALL PAC K 4' SURFACE MOUNT LED STRI P 6" Surface Ceiling downlight Pendant Ceiling Light Ceiling Light Shower Light LED vanity light LED Sconce .................................................................................................... Exterior Ressed Light Exterior LED Sconce Storage Closet Light Closet Ceiling Light LIGHTING FIXTURE SCHEDULE NOTES: Site and Second floor Court Yard GARAGE GARAGE ROOF Unit kitchen, living, hallway ..................... Unit kitchen Unit Bedrooms Unit Entry Unit Bathrooms Unit walk in Closets 2nd Floor Unit Balconies .............................................................. 6th Floor Unit Balconies Unit Storage Closets Unit closets Louis Poulsen Series / Model Number Lighting Bysted TBD VAP 4000LM FST WD LITHONIA MVOLT GZ10 40K80CRI + MS110NWL VAP 4000LM FST WD LITHONIA MVOLT GZ10 40K80CRI BSL520 RAB Lighting LITHONIA HALO KICHLER ............................................. Kuzco TBD TBD Progress TB D TBD TB D TB D TB D ENTRAI2N MNSL L46 1 LL MVOLT GZN 40K M6 SLD612830WH120V 3482NI L16 .................................................................. Dalton FM7920 P7211-09EB Description Specification : #BYS-28W LED-3000K- 120-277V/60HZ-Corten-DIM 0-10V- 10000128534 Base Plate Cover : #5747811081 Lamping : LED (Included) Wattage (W) : 28W Output (Im) : 4121m CCT (K) : 3000K CRI : 80+ Dimming Protocol : 0-10V (5%) Voltage (V) : 120/277V Distribution : Type V Label/IP : 44 Finish : Corten Height (ft) : 45" Size25-5/8-Inch Width x 5-1/4-Inch Height ColorBrushed Platinum StyleContemporary FinishNickel MaterialGlass Wattage17 watts 1. PROVIDE 2-HR FIRE -RATED J-BOXES FOR ALL RECESSED AND SURFACE MOUNT LED ULTRA -LOW PROFILE LIGHTING FIXTURES. 2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT QUANTITY AND LOCATION OF ALL LIGHTING FIXTURES. 3. VERIFY CEILING TYPE AND COORDINATE FIXTURE FINISH PRIOR TO PURCHASE OF FIXTURES. 4. EC TO VERIFY RUN LENGTHS PER PLAN AND COORDINATE PRIOR TO ORDERING. 5. PROVIDE ALL ACCESSORIES AND MOUNTING HARDWARE REQUIRED FOR COMPLETE INSTALLATION. 6. WHERE LIGHTING FIXTURES LOCATED WITHIN RATED CEILINGS OR WALLS PROVIDE UL APPROVED FIRE RATED ENCLOSURE. EMERGENCY LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION X XEM LED COMBINATION EXIT SIGN/EMER LIGHT XEM-WP XEMR LED THERMOPLASTIC EXIT SIGN WET COMBO EXIT SIGN/EMER LIGHT LED COMBINATION EXIT SIGN/EMER LIGHT WITH REMOTE CAPACITY RH LED OUTDOOR REMOTE HEAD(S) EB EMERGENCY BATTERY UNIT MANUFACTURER AND MODEL # COMPASS CER COMPASS CCR COMPASS CWC1RW COMPASS CCRRC COMPASS CORS or CORD COMPASS CU2 LAMP WATTS VOLTS LED 2 120 LED 4 120 LED 5.2 120 LED 4 120 LED 1 120 LED 1 120 E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc -ALL RIGHTS RESERVED Project #: 4017 IL w O o_ CC o_ a) C C co 0 ArchitectureSite w CID cn Cn w CC C3 CC 0_ CO CV w Q J O � SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 246 Walnut Street MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: 0 Zyi OF 1Hq ADAM DAVIDSON ELECTRICAL NO. 50519 • TEaso SsroHAL 0c' DRAWING #: co O U) U) U U) U) 2 a) C O a) Z CO COCO CO LC) ti CO 617 . 581 . 6601 NTS SCHEDULE ©TISE DESIGN ASSOCIATES, INC 2019 PANEL GPB STANDBY GENERATOR PANEL CKT. NO. Type 1 R 3 R 5 R 7 R 9 R 11 R 13 R 15 R 17 R 19 R 21 R 23 R 25 R 27 R 29 R 31 R 33 R 35 R 37 R 39 R 41 M CKT. NO. Type 1 R 3 R 5 R 7 R 9 R 11 R 13 L 15 R 17 R 19 R 21 R 23 R 25 L 27 R 29 R 31 M 33 M 35 M 37 M 39 M 41 M Load Description LTG BASEMENT LTG STAIRCASE S1 LTG STAIRCASE S2 LTG PUBLIC CORRIDOR 2 FL LTG PUBLIC CORRIDOR 3 FL LTG FIRST FL PEDESTRIAN WARNING SIGN SPARE SPARE GARAGE DOOR SPARE PANEL HPB Load Description PARKING LIFTS CONTROL PANEL PARKING LIFTS CONTROL PANEL LTG PUBLIC CORRIDOR 2&3 FL REC PUBLIC CORRIDOR 2&3 FL REC TEL/DATA CLOSETS 2&3 FL SPARE SPARE INTERCOM ELECTRIC STRIKE LTG CHANDELIER LOBBY SPARE SPARE RETAIL EUH-4A TEMPORARY RETAIL EUH-4B TEMPORARY PANEL MP CKT. NO. Type 1 M 3 M 5 M 7 M 9 M 11 M 13 M 15 M 17 M 19 M 21 M 23 M 25 M 27 M 29 M 31 M 33 M 35 M 37 M 39 M 41 M 43 45 47 49 51 53 55 57 59 Load Description EUI-I-3A GEF-1A GEF-2 SPARE GEF-3 GEF-1B SPARE SPARE SPARE SPARE SPARE SPARE SPARE Bus Amps: 400 Main: 400A MCB Mounting: SURFACE ST Main: No KVA LOAD A B C Bkr Type 111111111111111111111111111111111 111111111111111111111111111111111 AMP/ CKT. PH POLE 20/1 A 20/1 B 20/1 C 20/1 A 20/1 B 20/1 C 20/1 A 20/1 B 20/1 C A B C A B C A B 20/2 C A 15/3 B C Bus Amps: 225 Main: MLO Mounting: SURFACE ST Main: No KVA LOAD A B Bkr C J Type NO. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 AMP/ CKT. PH POLE A 40/3 B C A 40/3 B C 20/1 A 20/1 B 20/1 C G 20/1 A G 20/1 B 20/1 C 20/1 A 20/1 B 20/1 C A 60/3 B C A 60/3 B Bus Amps: 400 Main: MLO Mounting: SURFACE ST Main: No KVA LOAD A B C Bkr Type NO. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 C 42 208Y/120 VOLT, 3 PH, 4 Wire, 60 Hz A.I.C: 42,000 IG GND: NO Neutral: Full Type R R R R R R R R R R R M M M M M R R R R M Floor: BASEMENT Room: MAIN ELEC RM Closest Column Lines: Load Description FACP FA RPS FA RPS SMOKE/FIRE DAMPER SMOKE/FIRE DAMPER INTERCOM MAIN UNIT INTERCOM CONTROL UNIT SPARE SPARE SPARE SPARE GWP-1 GROUNDWATER PUMP EUH-1B EUH-2B EUH-3A 208Y/120 VOLT, 3 PH, A.I.C: 42,000 IG GND: NO Neutral: Full Type R R L L R R R R R R R M L M L M L R R R R KVA LOAD A B C Bkr Type L L L 4 Wire, 60 Hz Floor: BASEMENT Room: MAIN ELEC RM Closest Column Lines: Load Description EXTERIOR LTG VIA LC EXTERIOR LTG VIA LC LTG PARKING BASEMENT LTG PARKING LEVEL-1 REC MAIN TEL/DATA BOARD REC MAIN ELEC.RM REC PARKING GARAGE REC TRASH RM REC LEVEL-1 SPARE SPARE SPARE TRAFFIC CONTROL SIGN SPARE LTG WINDOWS DISPLAY SPARE LTG SUB -BASEMENT REC SUB -BASEMENT SPARE SPARE SPARE 208Y/120 VOLT, 3 PH, A.I.C: 42,000 IG GND: NO Neutral: Full AMP/ CKT. PH POLE NO. Type A 2 M 90/3 B 4 M C 6 M A 8 M 15/3 B 10 M C 12 M A 14 M 15/3 B 16 M C 18 M A 20 M 15/3 B 22 M C 24 M 15/1 A 26 M 15/1 B 28 M 15/1 C 30 M 15/1 A 32 M 15/1 B 34 M 20/1 C 36 M 20/1 A 38 M 20/1 B 40 M 20/1 C 42 M A 44 B 46 C 48 A 50 B 52 C 54 A 56 B 58 C 60 CIRCUIT BREAKER TYPE LEGEND: BLANK — STANDARD G — GROUND FAULT A — ARC FAULT ST — SHUNT TRIP L — HANDLE LOCK Load Description CUH-3 CUH-4 CUH-5 CUH-7 CUH-8 SPARE CUH-1 CUH-2 CUH-6 SPARE KVA LOAD A B J C ivy/////////////////////( Bkr Type 4 Wire, 60 Hz Floor: BASEMENT Room: MAIN ELEC RM Closest Column Lines: PANEL HPR AMP/ CKT. POLE NO. Type 20/1 1 R 20/1 3 R 20/1 5 R 20/1 7 R 20/1 9 R 20/1 11 R 20/1 13 R 20/1 15 R 20/1 17 R 20/1 19 R 15/1 21 R 20/1 23 R 25 R 90/3 27 R 29 R 31 R 90/3 33 R 35 R 37 M 90/3 39 M 41 M Load Description LTG ROOF REC ROOF REC UTILITY ROOMS ROOF LTG PUBLIC CORRIDOR 5&6 FL LTG PUBLIC CORRIDOR 4 FL REC TEL/DATA CLOSETS 4,5&6 FL REC PUBLIC CORRIDOR 5&6 FL SPARE REC PUBLIC CORRIDOR 4 FL SPARE SPARE SPARE SPARE RTU-1 PANEL GPR STANDBY GENERATOR PANEL AMP/ CKT. POLE NO. Type 20/1 1 R 20/1 3 R 20/1 5 R 20/1 7 R 20/1 9 R 20/1 11 R 20/1 13 R 20/1 15 R 20/1 17 R 20/1 19 R 20/1 21 R 20/1 23 R 20/1 25 R 20/1 27 R 20/1 29 R 20/1 31 R 20/1 33 R 20/1 35 R 20/1 37 R 20/1 39 R 20/1 41 M KVA LOAD Bkr AMP/ A B C Type POLE 25/2 25/2 25/2 25/2 25/2 25/2 15/2 15/2 15/2 15/2 Load Description GENSET BATTERY CHARGER GENSET BATTERY HEATER ELEVATOR SHAFT LOUVER ELEVATOR CKT#1 ELEVATOR CKT#2 ELEVATOR CKT#3 ELEVATOR CKT#4 GAS WATER HEATER's BOILERS HOT WATER CIRC. PUMP ELEV-1 Bus Amps: 225 Main: 150A MCB Mounting: SURFACE ST Main: No KVA LOAD A B C A Bkr Type 208Y/120 VOLT, 3 PH, 4 Wire, 60 Hz A.I.C: 22,000 IG GND: NO Neutral: Full AMP/ CKT. PH POLE NO. Type 20/1 A 20/1 B 20/1 C 20/1 A 20/1 B 20/1 C 20/1 A 20/1 B 20/1 C 20/1 A 20/1 B 20/1 C 20/1 A B C A B C A 70/3 B C Bus Amps: 225 Main: 150A MCB Mounting: SURFACE ST Main: No KVA LOAD B C Bkr Type AMP/ PH POLE 20/1 A B 20/2 C 20/1 A 20/1 B 20/1 C 20/1 A 20/1 B 20/1 C 20/1 A B C A B C A B 15/2 C A 70/3 B C 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CKT. NO. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 Floor: ROOF Room: ELEC RM Closest Column Lines: Load Description LTG ROOF CANOPY VIA TC LTG ROOF CANOPY VIA TC DEF's DEF's DEF's SPARE SPARE SPARE SPARE HP-x1 CU-10 CUH-9 KVA LOAD A B C Bkr Type 208Y/120 VOLT, 3 PH, 4 Wire, 60 Hz A.I.C: 22,000 IG GND: NO Neutral: Full Type L L L L L L L L L L L M M M M M R R R R M PAN»I,'LBOARD SCHf 'DUL f ' ' HP2' LOADCENTER MAIN M.C.B. CKT No. HP2 100A 100A/2P VOLTAGE 120 / 240V PHASE/WIRE 1—PH / 3W AIC 22,000 AMPS —POLES DESCRIPTION OF LOAD 1 20A-1P REC RESTROOMS 3 20A-1P TEF's RESTROOMS 5 20A-1P REC FITNESS ROOM 7 20A-1P REC FITNESS ROOM 9 20A-1P REC FITNESS ROOM 11 20A-1P REC FITNESS ROOM 13 20A-1P REC FITNESS ROOM 15 20A-1P SPARE 17 20A-1P SPARE 19 20A-1P(GFCI) SPARE 21 23 Floor: ROOF Room: ELEC RM Closest Column Lines: Load Description LTG STAIRCASE S1 LTG STAIRCASE S2 LTG ROOF UTILITY ROOMS LTG PUBLIC CORRIDOR 6 FL LTG PUBLIC CORRIDOR 5 FL LTG PUBLIC CORRIDOR 4 FL FA RPS FA RPS FA RPS FA BDA FA BDA SMOKE/FIRE DAMPER SMOKE/FIRE DAMPER SMOKE/FIRE DAMPER SPARE SPARE SPARE SPARE ELEV-2 GROUND BUS YES MOUNTING RECESSED LOCATION FITNESS ROOM DESCRIPTION OF LOAD LTG TERRACE LTG FITNESS/RESTROOMS REC TERRACE LTG COMMUNITY RM REC COMMUNITY RM REC COMMUNITY RM REC COMMUNITY RM COUNTERTOP REFRIGERATOR COMMUNITY RM DISHWASHER COMMUNITY RM MICROWAVE COMMUNITY RM AHU INDOOR UNIT KVA LOAD A B C llllllllllllll 11111111 1111 Bkr Type L L L L L AMPS —POLES 20A-1P 20A-1P 20A-1P 20A-1P 20A-1P 20A-1P 20A-1P 20A-1 P(GFCI) 20A-1 P(GFCI) 20A-1P 15A-2P CKT No. 2 4 6 8 10 12 14 16 18 20 22 24 AMP/ POLE 20/1 1 20/1 3 20/1 5 20/1 7 20/1 9 15/1 11 15/1 13 15/1 15 15/1 17 19 21 23 25 27 29 31 30/2 33 35 15/2 37 39 25/2 41 AMP/ POLE 20/1 1 R 20/1 3 R 20/1 5 R 20/1 7 R 20/1 9 R 20/1 11 R 20/1 13 R 20/1 15 R 20/1 17 R 20/1 19 R 20/1 21 R 20/1 23 R 20/1 25 R 20/1 27 R 20/1 29 R 20/1 31 R 20/1 33 R 20/1 35 R 37 R 70/3 39 41 PANEL PP1 CKT. NO. Type Load Description ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC SPARE SPARE PANEL PP2 CKT. NO. Type Load Description ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC SPARE SPARE Bus Amps: 225 Main: MLO Mounting: SURFACE ST Main: No KVA LOAD A B J C 4111111111111111111111111111111111111111, Bkr AMP/ Type POLE G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 Bus Amps: 225 Main: MLO Mounting: SURFACE ST Main: No KVA LOAD A B J C 11111111111111111111111111111111111, J Bkr AMP/ Type POLE G 20/1 G 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 208Y/120 VOLT, 3 PH, A.I.C: 42,000 IG GND: NO Neutral: Full CKT. PH NO. Type 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CKT. PH NO. A 2 B 4 C A B C A B C A B C A B C A B C A B C 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 4 Wire, 60 Hz Floor: BASEMENT Room: MAIN ELEC RM Closest Column Lines: Load Description ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC 208Y/120 VOLT, 3 PH, A.I.C: 42,000 IG GND: NO Neutral: Full Type R R R R R R R R R R R M M M M M R IIV KVA LOAD A B C Bkr AMP/ Type POLE G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 4 Wire, 60 Hz Floor: BASEMENT Room: MAIN ELEC RM Closest Column Lines: Load Description ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC ELECTRIC VEHICLE CHARGING REC TYPICAL UNIT LOADCH,'NT H,'R SCHH,'DUL H,' LOADCENTER MAI N M.C.B. LC 100A M.L.O. CKT AMPS —POLES No. 1 3 VOLTAGE PHASE/WIRE AIC DESCRIPTION OF LOAD 30A-2P DRYER 5 15A-1P (AFCI) REFRIGERATOR 7 20A-1P (\A� 9 20A-1P OA 11 15A-1P (AFCI) 13 20A-1P (AFCI) 15 15A-1P 17 15A-1P 19 15A-1P 21 15A-1P 23 15A-1P (AFCI) (AFCI) (AFCI) (AFCI) KITCHEN SMALL APPLIANCE KITCHEN SMALL APPLIANCE HOOD/MICROWAVE LIVING RM REC LAUNDRY RM WASHER LEAK SENSOR 120 / 240V 1—PH / 3W 10,000 GROUND BUS YES MOUNTING RECESSED LOCATION SEE FLOOR PLAN DESCRIPTION OF LOAD WASHER GARBAGE DISPOSAL DISHWASHER MASTER BATHROOM REC & LTG BATHROOM REC & LTG OR SPARE LIGHTING/SMOKE DETECTORS SPARE BATHROOM BASEBOARD HEATER AND DRYER BOOSTER FAN REC (IF APPLICABLE) MASTER BEDROOM REC BEDROOM(S) REC OR SPARE HALLWAY REC / MEDIA PANEL MECH.CLOSET REC / GAS WATER HEATER AHU INDOOR (VERTICAL) UNIT (IF APPLICABLE) HP HEAT PUMP OUTDOOR UNIT AND FCU (IF APPLICABLE) KVA LOAD A B AMPS —POLES 20A-1P OA 20A-1P OA 20A-1P OA 20A-1P 20A-1P 15A-1P (AFCI) 15A-1P (AFCI) 20A-1P 15A-2P 30A-2P CKT No. 2 4 6 8 10 12 14 16 18 20 22 24 OA — PROVIDE DUAL FUNCTION GFCl/AFCI CIRCUIT BREAKER BO — INDOOR HORIZONTAL FAN COIL UNITS (FCU) SHALL BE FED FROM ASSOCIATED HEAT PUMP OUTDOOR UNIT HP. PROVIDE 3#12 WIRING IN 3/4" CONDUIT BETWEEN OUTDOOR AND INDOOR UNITS. VERIFY WIRING REQUIREMENTS WITH MANUFACTURER'S RECOMMENDATIONS. REFER TO HVAC FLOOR PLANS FOR FCU's EXACT LOCATIONS. O — REFER TO HVAC FLOOR PLANS FOR AHU's EXACT LOCATIONS. AHU SHALL BE FED FROM THE DWELLING UNIT LOAD CENTER 'LC' OPPOSED TO FCU, WHICH IS FED FROM OUTDOOR HEAT PUMP. PROVIDE CIRCUIT BREAKER AS INDICATED ON THE 'LC' SCHEDULE FOR AHU OR LEAVE BLANK SPACE. GENERAL LOADCENTER SCHEDULE NOTES: 1. WIRING DEVICES SERVED FROM CIRCUIT BREAKERS RATED 20A-1P SHALL BE RATED 20A, 125V. 2. WIRING DEVICES SERVED FROM CIRCUIT BREAKERS RATED 15A-1P SHALL BE RATED 15A, 125V. E Bkr Type AMP/ POLE G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 G 20/1 20/1 20/1 20/1 20/1 EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 uJJ C/) C7 CL CC d PROGRESS SET LJ C.D J co T • CV Uu >- SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. 0 DRAWING TITLE: REGISTRATION: 246 Walnut Street SCHEDULES ty�ofi� d ADAM 41 I DAVIDSON m ELECTRICAL -4NO. 50519 • ft►ONAL OC' DRAWING #: X Co T- T- CO CO co L CO NTS ©TISE DESIGN ASSOCIATES, INC 2019