6_PlumbingDESIGNATION FD-A FD-B FD-C FD-D GD-A RD-A TD-A HOSE BIBB HB WALL HYDRANT WH FCO SYMBOL WHT-1 WHT-2 PIPE RESIDENCE WATER WASTE/VENT GAS GARAGE WASTE/VENT GARAGE WASTE/VENT PIPING AT GWH WATER DESIGNATION BFP-1 FIXTURE NUMBER P-1 P-1A P-2 SCHEDULE OF ROOF &FLOOR DRAINS, HOSE BIBB, WALL HYDRANT, AND FLOOR CLEANOUTS LOCATION WATER ROOM TRASH ROOM TERRACE PLANTER GARAGE ROOF GARAGE TRASH ROOM PARKING EXTERIOR SEE PLANS MANUFACTURER WATTS WATTS JAY R. SMITH JAY R. SMITH WATTS WATTS ZURN WOODFORD WATTS WATTS MODEL NO FD-100-A5 FD-340-Y-5-7 14-- 2685 FD-490-F-4 RD 300-DB Z886-HPS-RPSC STAINLESS STEEL WB-875 HY-420 CO 200-RX H-20-NICKEL BRONZE ROUND COMMENTS 1. PROVIDE TRAP PRIMER & ASSOCIATED PIPING 1. PROVIDE TRAP PRIMER & ASSOCIATED PIPING SEE SPECIFICATION 1. FLASHING COLLAR 2. STANDPIPE AND DOME 1. 12" SQ TOP 2. WITH BUCKET 3. WITH TRAP PRIMER & ASSOCIATED PIPING 1. DECK CLAMP 2. SUMP PAN 1.PROVIDE TRAP PRIMER 1. AUTOMATIC DRAIN 2. W/VACUUM BREAKER 1. AUTOMATIC DRAIN 2. SURFACE MOUNTED PIPING & ASSEMBLY REFER TO PLAN FOR LOCATION OF FCO ALL FCO LOCATIONS TO BE APPROVED BY OWNER - GARAGE WATER HEATER/STORAGE TANK SCHEDULE INPUT (BTUH) FROM BOILER LOW / HIGH 383,000 383,000 STORAGE CAP. 1 19 GAL. 1 19 GAL. MANUFACTURER & MODEL LAARS A0070101 LAARS A0070101 DIMENSIONS IN INCH D29"XH60" D29"XH60" PIPE SPECIFICATION MATERIALS MATERIAL COMMENT C PVC PVC-40 SCHEDULE 40 BLACK STEEL CAST-IRON W/MECHANICAL JOINTS CAST-IRON W/PUSH ON JOINTS - BELL & SPIGOT TYPE L COPPER W/ SOLDERED JOINTS TYPE K COPPER W/ SOLDERED JOINTS LOCATION NOTES ALL RESIDENTIAL 2" AND SMALLER PIPING WITHIN UNITS ABOVE GROUND & BELOW GROUND SCHEDULE 40 PVC PIPING FOR RESIDENCE USED FOR ALL GAS PIPING - ELEVATED GAS PIPING TO BE WELDED USED FOR ALL GARAGE WASTE & VENT PIPING ABOVE GROUND USED FOR ALL GARAGE WASTE & VENT PIPING BURIED REQUIRED AT GWH FOR MIN 20" ON INLET/OUTLET LAGER THAN 2" SCHEDULE OF BACKFLOW PREVENTERS WATER METER DESCRIPTION WATER CLOSET WATER CLOSET LAVATORY P-2A ICI LAVATORY P-3 P-4 P-4A P-5 P-5A P-6 P-7 P-8 SYMBOL GWP-1 GWP-2 BATH TUB SHOWER SHOWER KITCHEN SINK KITCHEN SINK LAUNDRY BOX W/ AUTOMATIC SHUT-OFF ICE MAKER MOP SINK MANUFACTURER WATTS I MANUFACTURER NAME GPM HEAD TD H SUBMERSIBLE PUMP KOHLER KOHLER AMERICAN STANDARD AMERICAN STANDARD MIRABELLE SITKA COLLECTION MINCEY MARBLE MINCEY MARBLE VIGO VIGO WATTS OATEY MUSTEE MODEL NUMBER 009-QT MODEL SANTA ROSA K-3810 SANTA ROSA K-3810 OVALYN 0496.221 OVALYN 0496.221 SIZE 4" FIXTURE I TYPE 6032 AIR BATH, WHIRLPOOL TUB TD-3660-OS/SF TD-3660-OS/SF VGR301 9C VGR301 9C A2C-WB-M 1 12K 63M ELECTRICAL V AMP HP 10 30 115 1 /2 RIGHT HEIGHT 1.28 GPF RIGHT HEIGHT 1.28 GPF UNDERMOUNT UNDERMOUNT WHITE ACRYLX WHITE RESTS ON SUB FLOOR WHITE RESTS ON SUB FLOOR REMARKS 1.PROVIDE TEST KIT 2.PROVIDE STRAINER SIZE FLOOR MOUNTED FLOOR MOUNTED PLUMBING FIXTURE SCHEDULE 1. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH THE NEW MASSACHUSETTS STATE BUILDING CODE, PLUMBING CODE, ALL APPLICABLE LOCAL CODES AND ORDINANCES. THIS CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND APPROVALS. 2. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL PLUMBING EQUIPMENT WITH THE ELECTRICAL DRAWINGS AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN THEREIN. 3. SHOP DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THE ARCHITECT PRIOR TO ORDERING, PURCHASING, OR FABRICATING ANY MECHANICAL EQUIPMENT. SHOP DRAWINGS SHALL INCLUDE ALL EQUIPMENT SCHEDULED ON THE DRAWINGS, PLUMBING FIXTURES AND TRIM, PIPING, VALVES, FITTINGS, INSULATION AND THE LIKE AS SHOWN ON THE DRAWINGS. 4. ALL PLUMBING EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 5. ALL PIPING PENETRATING CEILINGS AND WALLS SHALL BE INSTALLED WITH CHROME PLATED ESCUTCHEONS AT THE PENETRATION. ALL PIPING PENETRATING EXTERIOR WALLS AND ROOFS SHALL BE FLASHED IN AN APPROVED MANNER AND SHALL BE SEALED WATERTIGHT. PIPING PENETRATING FIRE RATED PARTITIONS, FLOOR OR CEILING SHALL BE PROTECTED AS REQUIRED BY LOCAL CODE AUTHORITY. 6. ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER START-UP. 7. ALL PLUMBING EQUIPMENT, PIPING, INSULATION, ETC., SHALL MEET CODE REQUIREMENTS FOR SMOKE AND COMBUSTIBILITY. 8. VALVE LOCATIONS ARE DIAGRAMMATIC. ACTUAL LOCATIONS SHALL BE WITHIN REACH WHEN STANDING ON THE FLOOR (WHEN PIPING IS EXPOSED) OR AT JUST ABOVE THE DROPPED CEILINGS (WHEN PIPING IS CONCEALED) 9. ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. PIPING SHALL BE HUNG FROM APPROVED LOCATIONS ON THE STRUCTURE. 10. REFER TO ARCHITECTURAL DRAWINGS FOR NAMES OF ALL ROOMS AND AREAS. 11. ANY INTERFERENCE SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER AND OWNER'S REPRESENTATIVE. THESE ISSUES SHALL BE RESOLVED PRIOR FABRICATION, ORDERING OF MATERIAL, AND INSTALLATION. 12. PROVIDE ACCESS PANELS FOR EQUIPMENT THAT REQUIRES PERIODIC SERVICE. 13. PROVIDE SHUT OFF VALVES ON ALL BRANCH PIPING AND ALL SUPPLIES TO INDIVIDUAL FIXTURES AND EQUIPMENT. ALL VALVES SHALL BE ACCESSIBLE. 14. RUN PIPING CONCEALED, UNLESS OTHERWISE SPECIFIED, CLEAR OF CEILING INSERTS. 15. PROVIDE CLAMPS, OFFSETS, EXPANSION JOINTS, ANCHORS AND GUIDES AS NECESSARY TO PREVENT STRESS ON PIPING. 16. VERIFY EXACT SIZES, LOCATIONS, INVERTS AND ELEVATIONS PRIOR TO RUNNING ANY PIPING. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF ALL FIXTURES AND EQUIPMENT. REFER TO EQUIPMENT DRAWINGS FOR EXACT LOCATION AND ROUGH -IN DIMENSIONS FOR ALL EQUIPMENT SUPPLIED BY OTHERS, REQUIRING PLUMBING CONNECTIONS. 17. PROVIDE CW LINE TO ELECTRIC FIREPLACE. PLUMBING FIXTURE SCHEDULE PLUMBING TRIM/FAUCETS MANUFACTURER I MODEL # I 17"x14" GROHE 17"x14" 60"x32"x20" 60"x36" 60"x36" GROHE GROHE GROHE GROHE UNDERMOUNT 28"x17"x9 7/8"" GROHE UNDERMOUNT 28"x17"x9 7/8"" GROHE RECESSED RECESSED FIBERGLASS 24"x24"x1 2" AMERICAN STAN DAR D GROUND WATER SUBMERSIBLE PUMP MANUFACTURER & MODEL LIBERTY PUMPS 405 SERIES LOCATION/SERVING SUB -BASEMENT FITTING TYPE MANUFACTURER I TYPE - BRASS CRAFT CHROME PLATED BRASS CRAFT CHROME PLATED 34270001 SINGLE HOLE ZURN CONCETTO 34270001 EUROPLUS #19881000 TUB SPOUT #1 3272000 GROHFLEX 350051 GROHFLEX 350051 SINGLE LEVER 31380 SINGLE LEVER 31380 HERITAGE 8354.1 1 2-RC004 REMARKS SINGLE HOLE ZURN DUAL FUNCTION PRESSURE BALANCE TRIM W/CONTROL MODULE DUAL FUNCTION DUAL FUNCTION SINGLE HOLE SINGLE HOLE IPS GROHE GROHE GROHE ZURN ZURN CHROME PLATED CHROME PLATED SUPPLY B1-12DLF B1-12DLF ZURN Z8808LR ZURN Z8808LR CHROME GROHFLEX PLATED #35026000 CHROME PLATED CHROME PLATED CHROME PLATED CHROME PLATED 1. SUBMERSIBLE PUMP 2. CORD LENGT 20' 3. 48"X48"X96" CONCRETE PIT BY G.C. 4. PLUMBING CONTRACTOR TO COORDINATE CONTROLS, PIT LOCATION AND UNDERGROUND PIPES IN THE FIELD GROHFLEX 350051 350051 ZURN Z8808LR ZURN Z8808LR TRAP INTEGRAL INTEGRAL ZURN ZR827-6BD-PC 2" W&T PRO FLOW PFP-600 2" W&T AND GRID STRAINER 2" W&T AND GRID STRAINER THE KENEYCOMPANY THE KENEYCOMPANY SOIL/ WASTE 4" 4" 2" 2" 2" 2" 2" 2" 2" 2" 2"W ITEM RTU-1 MUA-1 STOVE GWH GENERAITOR FIRE PLACE GAS FIXTURE SCHEDULE CFH I QUANTITY 180 1 400 1 70 61 399 2 2043 65 TOTAL CFH 180 400 4270 798 2043 65 LOCATION ROOF ROOF APARTMENTS ROOF BOILER ROOM ROOF LEVEL 1 METER NUMBER #1 GAS METER (COMMON AREA) #1 GAS METER (COMMON AREA) #1 GAS METER (APARTMENTS HOT WATER) #1 GAS METER (APARTMENTS HOT WATER) #1 GAS METER (COMMON AREA) COMMUNITY ROOM #2 GAS METERS RETAIL AREA (FUTURE) TOTAL LENGTH: 150 FEET TOTAL 7756 CFH REQUIRED 6"GAS PIPE AT LESS THAN 1 PSI INLET PRESSURE, PRESSURE DROP 0.3 IN W.C. AND 0.60 SPECIFIC GRAVITY. DESIGNATION WH-1 SCHEDULE OF WATER HAMMER ARRESTORS MANUFACTURER MODEL NUMBER SIZE ACCESSORIES ZURN ZZ-1700-200 200 FURNISH WITH VALVE AND ACCESS PANEL NOTES: 1. WATER HAMMER ARRESTORS SHALL BE OF ALL STAINLESS STEEL CONSTRUCTION, CONFORMING TO P.D.I. 2. SFU - SUPPLY FIXTURE UNIT. 3. PROVIDE WASTE HAMMER ARRESTOR AT WASHING MACHINE, DISHWASHER, & SHOWER VALVE LOCATION TAG TMV-1 SYMBOL LOCATION BOILER ROOM NAME STANDARD 201-1. THERMOSTAT MIXING VALVE SCHEDULE MODEL MANUFACTURER LFMMV WATTS COMMENTS MIXING VALVE ASSEMBLY W/ OUTLET THERMOMETER & ISOLATION VALVE, VACUUM BREAKER, MOUNTING BRACKET - CAST COPPER ALLOY BODY HOT WATER CIRCULATION PUMP SCHEDULE GHEAD PM TDH CP-1,2 CIRCULATOR PUMP 6 20 P-1 HEATING WATER 40 35 P-2 HEATING WATER 40 35 SYMBOL B-1 80,000/393,000 96 B-2 80,000/393,000 96 230 230 230 ELECTRICAL PH HZ HP 1 60 1/4 3 60 1 1/2 3 60 1 1/2 MANUFACTURER & MODEL WILO STRATOS Z 1.25X3-25 WILO TOP-S 2x50 WILO STRATOS 2x50 GAS CONDENSING WATER HEATER/BOILER SCHEDULE INPUT (BTUH) FROM BOILER LOW / HIGH THERMAL EFFICIENCY DELIVERY(GPH) 40F TO 140°F RISE 461 461 MANUFACTURER & MODEL LAARS, NEOTHERM NW 399 LAARS, NEOTHERM NTV 399 NOTES: 1. PROVIDE NEUTRALIZED KIT 2. PIPE CONDENSATE TO FD IN BOILER ROOM. 3. PROVIDE 4"0 COMBUSTION AIR AND 4"0 EXHAUST VENT PIPES. VENT CW HW CARRIER H/C MTD. 2" 1/2" N/A N/A N 2" 1/2" N/A N/A Y 2" 1/2" 1/2" N/A N 2" 1/2" 1/2" N/A Y 2" 1/2" 1/2" N/A N 2" 1 /2" 1 /2" N/A N 2" 1 /2" 1/2" N/A Y 2" 1/2" 1/2" N/A Y 2" 1/2" 1/2" N/A Y 2" 1/2" 1/2" N/A N - 1/2" - - 2" 1/2" 1/2" N/A N REMARKS ELECTRICAL 115-1-60 AMPS 115-1-60 AMPS REMARKS STAINLESS STEEL CIRC. FOR DOMESTIC USE DIMENSIONS WEIGHT IN INCH LB W25"xL32"xH38" 364 W25"xL32"xH38" 364 1. PROVIDE HEAVY DUTY CLOSED SEAT & COVER. 2. REFER TO ARCH. DWGS FOR ELEVATIONS. 1. PROVIDE HEAVY DUTY CLOSED SEAT & COVER. 2. REFER TO ARCH. DWGS FOR ELEVATIONS. 1. PROVIDE INSULATION GUARD KIT ON CW, HW, & WASTE. 1. PROVIDE INSULATION GUARD KIT ON CW, HW, & WASTE. 1. PROVIDE ACRYLIC TOWEL BAR. 2. PROVIDE CURVE CURTAIN ROD, HOOKS, & CURTAIN. 3. PROVIDE FULL HEIGHT WOOD REINFORCEMENT ON ALL SIDES 1. PROVIDE SHOWER ROD, CURTAIN & HOOKS 2. SHOWER HEAD GROHE, "EUPHORIA" (27492), 2.5 GPM 1. RAINSHOWER 12" SHOWER ARM (28 577) 1 PROVIDE SHOWER ROD, CURTAIN & HOOKS 2. SHOWER HEAD GROHE, "EUPHORIA" (27492), 2.5 GPM 1. RAINSHOWER 12" SHOWER ARM (28 577) 1. STAINLESS STEEL SINK GRID #223200 2. LAVATORY SUPPLY STOP LFST082 1. STAINLESS STEEL SINK GRID #223200 2. LAVATORY SUPPLY STOP LFST082 1. PROVIDE 120 VOLT POWER. 2. LEAK SENSOR 1. WITH QUARTER TURN VALVE 2. WITH WATER HAMMER ARRESTOR 1. HOSE AND MOP HANGER BRACKETS NOTES 1+2+3 1+2+3 P0.1 PLUMBING P0.2 PLUMBING P0.3 PLUMBING P0.4 PLUMBING P0.5 PLUMBING P1.OSB PLUMBING P1.0 PLUMBING P1.1 PLUMBING P1.1CLG PLUMBING P1.2 PLUMBING P1.3 PLUMBING P1,4 PLUMBING P1.5 PLUMBING P1.6 PLUMBING P1,7 PLUMBING P2.1 PLUMBING H2.2 PLUMBING P2,3 PLUMBING P2.4 PLUMBING P2.5 PLUMBING PLUMBING LEGEND SYMBOL (NEW) IW C GW GW Gv Gv TP 0 )O O O 0 3 ---F LIST OF PLUMBING DRAWINGS LEGEND AND NOTES DETAILS RISER DIAGRAMS SANITARY RISER DIAGRAMS -A SANITARY RISER DIAGRAMS-B SUB -BASEMENT FLOOR PLAN BASEMENT FLOOR PLAN FIRST FLOOR PLAN FIRST FLOOR PLAN-CLG SECOND FLOOR PLAN THIRD FLOOR PLAN FOURTH FLOOR PLAN FIFTH FLOOR PLAN SIXTH FLOOR PLAN ROOF PLAN ENLARGED UNIT PLANS ENLARGED UNIT PLANS ENLARGED UNIT PLANS ENLARGED UNIT PLANS ENLARGED UNIT PLANS ABBR. DESCRIPTION S or W SOIL or WASTE PIPING S or W SOIL or WASTE PIPING (BURIED or BELOW FLOOR) COND CONDUCTOR PIPING COND CONDUCTOR PIPING (BELOW SLAB) ✓ VENT PIPING ✓ VENT PIPING (BELOW SLAB) CW DOMESTIC COLD WATER PIPING CW BURIED WATER SERVICE HW DOMESTIC HOT WATER PIPING IW INDIRECT WASTE CHW CIRCULATION HOT WATER G NATURAL GAS PIPING G NATURAL GAS PIPING (BURIED) GW GARAGE WASTE PIPING GW GARAGE WASTE PIPING (BURIED) GV GARAGE VENT PIPING GV GARAGE VENT PIPING (BURIED) TP TRAP PRIMER INT O.A. INTAKE FOR HOT WATER HEATER EXH EXHAUST FLUE FOR HOT WATER HEATER METER BV BALL VALVE NGC NATURAL GAS COCK CV CHECK VALVE DV DRAIN VALVE HOT WATER CIRCULATION VALVE CO LINE CLEAN OUT FCO FLUSH FLOOR CLEAN OUT PIPE CAP PIPE CONTINUATION PIPE UP THRU SLAB OF FLOOR ABOVE PIPE DOWN THRU FLOOR SHOWN PIPE DROP W&T WASTE & TRAP BFP BACKFLOW PREVENTOR OED OPEN END DRAIN FD FLOOR DRAIN GD GARAGE DRAIN AD AREA DRAIN RD ROOF DRAIN WH WALL HYDRANT HB HOSE BIBB TMV THERMOSTATIC MIXING VALVE CWR COLD WATER RISER HWR HOT WATER RISER W&V WASTE & VENT PIPING SS SOIL STACK WS WASTE STACK VS VENT STACK VTR VENT THRU ROOF RL ROOF LEADER GOO GRADE CLEANOUT DCO DANDY CLEANOUT WCO WALL CLEANOUT HD HEAVY DUTY TOR TOP OF ROOF INV. EL. INVERT ELEVATION FIN. FL. FINISH FLOOR ELEV. ELEVATION NTS NOT TO SCALE PSC PLUMBING SUB -CONTRACTOR LS LAUNDRY WASTE STACK KS KITCHEN WASTE STACK AP ACCESS PANEL CI CAST IRON PVC POLYVINYL CHLORIDE TYPE-A,B,C,D & B1 & A2,B2 TYPE-A2,B2,C2 & B3,C1 TYPE-E,F,G & G1,G2 & H,K TYPE-L,P,T & J,U TYPE -COMMON AREA & RETAIL E SPACE EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 cw/) 0_ CC 0 w ArchitectureSite PROGRESS SET 0 N SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. 0 a) DRAWING TITLE: REGISTRATION: DRAWING #: IP) 246 Walnut Street 0 co O co U, U co 2 a) C 0 z NTS U) 0 z z Z W 1-1 PLUMBING 617 . 581 . 6601 ©TISE DESIGN ASSOCIATES, INC 2019 BRONZE TEST COCK (TYP) STRAINER INSULATION PRESSURE' GAUGE ASSEMBLY BRONZE PIPE SUPPORT SADDLE GALVANIZED SUPPORT PIPE GALVANIZED PIPE FLANGE BOLTED TO FLOOR BEAM, PURLIN IOR TRUSS LOCK NUT MALLEABLE IRON C—CLAMP MACHINE I THREADED ROD CARBON STEEL SWIVEL RING STRAP HANGER DETAIL FOR 2" & SMALLER PIPE I I ECCENTRIC LOADING 1" TO FLOOR DRAIN WATTS 909 AG—C AIR GAP FINISHED FLOOR rti NOTES: 1. PROVIDE SPARE PARTS KIT FOR EACH DIFFERENT SIZE UNIT INCLUDING GASKETS, SPRINGS, & MAIN ASSEMBLIES. 2. MOUNT IN ACCORDANCE WITH LOCAL REGULATIONS WITH CLEARANCE FROM WALLS AND OTHER OBSTRUCTIONS. BACKFLOW PREVENTER NOT TO SCALE BEAM, PURLIN OR TRUSS DETAIL FOR 2?" TO 3" PIPE MALLEABLE BEAM CLAMP ROD COUPLING MACHINE ITHREADED ROD CARBON STEEL SWIVEL RING STRAP HANGER DOUBLE NUTS CONCENTRIC LOADING ONLY REDUCED PRESSURE PRINCIPLE �♦ BACKFLOW PREVENTER SHUT—OFF VALVE (TYP) PRESSURE GAUGE ASSEMBLY (TYP.) 3'-6" — i 3. REFER TO DRAWINGS FOR LOCATION & TYPE (SIMPLEX OR DUPLEX) 4. BACKFLOW PREMIERS TO BE MOUNTED W'-6' AFF MAX BEAM, PURLIN OR TRUSS DETAIL FOR 4" & LARGER MALLEABLE BEAM CLAMP ROD COUPLING MACHINE THREADED ROD SINGLE NUT CLEVIS HANGER PIPE HANGERS FROM BOTTOM OF BEAM, PURLIN OR TRUSS NOT TO SCALE DUCTILE IRON BODY WITH INTERNAL AND EXTERNAL FDA APPROVED EPDXY COATING AND STAINLESS STEEL INTERNAL PARTS OS&Y VALVE WITH SUPERVISORY SWITCH FIRE SERVICE MAIN — A !- 3' TO 4' ABOVE FINISHED FLOOR FINISHED FLOOR r NOTES: OS&Y VALVE WITH SUPERVISORY SWITCH TO SYSTEM D❑MESTIC COLD WATER —HOT WATER HOT WATER STORAGE TANK DISHWASHER LOOPED HIGH AND SECURELY FASTENED TO COUNTER OR WALL . 01 HOT WATER STORAGE TANK DHWR n VACUUM BREAKER -44 — — —s 1" RECIRC, MAIN -4111 MANUAL AIR VENT w 1 AIR SCOOP III ET-1 DHWS DHWR B❑ILER B-1 1 T i T CP-1 B❑ILER B-2 DOMESTIC WATER HEATERS WITH STORAGE TANKS DETAIL NOT TO SCALE AIR CAP FITTING FOOD —WASTE —GRINDER 1 1/2"V TYPICAL SINK, DISHWASHER AND FOOD WASTE GRINDER DETAIL NOT TO SCALE ADJUSTABLE GALVANIZED PIPE SUPPORT WITH GALVANIZED STEEL SADDLE, LOCKNUT NIPPLE & CAST IRON REDUCER, USED IN CONJUNCTION WITH PIPE STANDARD AND FLANGE AT THE BASE. SUPPORT SYSTEM SHALL COMPLY WITH FEDERAL SPECIFICATION WW—H-171 (TYPE 39) AND MANUFACTURERS STANDARDIZATION SOCIETY SP-69 (TYPE 38) (TYPICAL) 1. BACKFLOW PREVENTER SHALL BE APPROVED BY THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AGENCY. 2. BACKFLOW PREVENTER SHALL BE IN COMPLETE ACCORDANCE WITH AUTHORITIES HAVING JURISDICTION. THE PLUMBING CONTRACTOR SHALL SUBMIT PLANS AND DEVICE INFORMATION FOR APPROVAL PRIOR TO INSTALLATION. 3. FURNISH TO OWNER ONE TEST KIT AND SPARE PARTS KIT FOR EACH DEVICE. 4. THIS CONTRACTOR SHALL ACT AS THE OWNERS AGENT IN SEEKING APPROVAL FROM ALL LOCAL AND STATE AUTHORITIES. THIS CONTRACTOR SHALL SUBMIT ALL PLANS, SPECS. AND APPLICATIONS REQUIRED FOR APPROVAL AND PAY ALL FEES. 5. SEE FLOOR PLANS FOR SIZES. 6. MAINTAIN 1'-0" CLEARANCE FROM WALL. REDUCED PRESSURE BACKFLOW PREVENTER FOR PIPE SIZES 2%2" AND LARGER NOT TO SCALE 24" DIA. C.I. HEAVY DUTY FRAME & COVER W/CENTER HOLE FINISHED GRADE 15.61' 4"EXTRA HEAVY C.I. INLET SEE BELOW INV. EL. 13.00' 8" WATER �1 WROUGHT �DJ IRON \_ STEPS 18"o.c. 2'-6" • v . ° .° v ° Iv•° • • 4" VENT TO ROOF INDEPENDENTLY 1/8 LONG BEND LEVEL_\ v . v v 4'-0"DIA. 8" PORTLAND CONCRETE GENERAL CONSTRUCTION NOTES: THE SEPARATOR IS TO BE LOCATED OUTSIDE OF A BUILDING WHERE POSSIBLE AND THE COVER IS TO INCORPORATE A CENTER —HOLE. A SEALED TIGHT COVER IS TO BE USED IF THE SEPARATOR SHALL BE LOCATED AND CONSTRUCTED TO PREVENT SURFACE OR SUB —SURFACE WATER FROM ENTERING. THE INLET PIPE SHALL BE NO LESS THAN FOUR INCHES ABOVE THE WATER LINE LEVEL. WHEN THE SEPARATOR IS SUBJECT TO FREEZING IT SHALL BE SET A MINIMUM OF THREE FEET BELOW GRADE. THE SEPARATOR SHELL BE FILLED WITH WATER AND LEAK TESTED BEFORE BEING INTRODUCED INTO SERVICE. THE NON —CORROSIVE STEPS SHALL BE SPACED AT 18"—INCHES APART. THE CHAMBER VENT AND OUTLET VENT SHALL RETURN TO THE INSIDE OF THE BUILDING AND EXTEND THROUGH THE ROOF. V • V 4"C.I. TEE 4"OUTLET TO SANITARY SEWER EL: 12.8' EXTRA HEAVY C.I. PIPE SOLID CONCRETE PRECAST WITH WATER TIGHT CONNECTIONS ALL CONCRETE SHALL CONSIST OF 1 PART CEMENT, 2 PARTS SAND. (CEMENT BRICK OR HOLLOW CONC. OR CINDER BLOCK MASONRY MUST NOT BE USED.) BY GEN. CONTR. INTERCEPTOR SIZE INLET A B C 4" 14'—O"' 3'-0" 2'-6" I 5" 3'-6"5'-0" 4'-0" 3'-6"x3'-6" 4'-0" 3'-0" 4'-0' 3'-6" 3'-0" 4'-0"x4'-0" 3'—O" 2'-6" 4'-6"' 3'-0" 2'-6" 6" 4'—O"' 5'-0" 4'-6" 4'-0"x4'-0" 4'-0" 3'-6" 4'-6"' 4'-0" 3'-6" 4'-6"x4'-6" 3'-6" 3'-0" 5'—O"' 3'-6" 3'-0" 5'-0"x5'-0" 3'-0" 2'-6" 8" 5'-0"' 6'-0" 5'-0" 4'-6"x4'-6" 4'-6" 4'-0" 6'-0'" 4'-0" 3'-6" 6'-0"x6'-0" 3'—O" 2'-6" 3'-6" 3'-0" 6'-6"x6'-6" 3'-0" 2'-6" PIPING MATERIAL NOTES: A. NO —HUB CAST IRON WITH PRODUCT —APPROVED STAINLESS STEEL CLAMPS B. SERVICE WEIGHT CAST IRON WITH PRODUCT —APPROVED RESILIENT GASKETS C. EXTRA HEAVY CAST IRON WITH PRODUCT —APPROVED RESILIENT GASKETS OR LEAD AND OAKUM JOINTS DETAIL OF GAS/OIL AND SAND INTERCEPTOR NOT TO SCALE I- 00H VACUUM BREAKER MANUAL AIR VENT PIPE TO EXISTING STORM WASTE NEW GRATING —\ EXISTING CIRCULAR 1— SUMP PUMP PIT AIR SCOOP III ET-2� UNION 2'— )I II II II .0 NEW LIBERTY PUMPS MODEL 405 SUBMERSIBLE EFFLUENT PUMP, 1/2 HP, 115 VOLTS, 2" DISCHARGE, 30 TDH, 10 GPM O BALL VALVE O3 CHECK VALVE Ak PUMP ON —OFF FLOAT SUBMERISIBLE PUMP 10-0" POWER CORD PLUG TO 15AMP GFCI OUTLET BY ELECTRIC O PUMP PRESSURE DISCHARGE PIPING © 15 AMP GFCI OUTLET BY ELECTRIC NEW SUMP PUMP PIT DETAIL NOT TO SCALE 2" VENT PIPE CLAMP FINISHED FLOOR 2" WASTE PIPE 1/2"CW TO FLOOR DRAIN FLOOR SINK/ FLOOR DRAIN VENT STACK r, AS INDICATED ON PLANS WASHER BOX REFER TO FIXTURE SCHEDULE 2" P—TRAP —� 2" WASTE --- J FRONT VIEW DETAIL OF WASHING MACHINE STACKS TRAP PRIMER �L - 1 /2" — PIPE 1/2" CW TO NEAREST CW SUPPLY TRAP PRIMER ASSEMBLY FOR FLOOR DRAIN &HUB DETAIL NOT TO SCALE NOT TO SCALE 4" X 6" INCREASER 4"PTRAP 4" BACKWATER VALVE ZURN Z-1090 OR EQUAL 4" X 12" 1/8 BEND 6" CONDUCTOR OPEN END DRAIN (OED) NOT TO SCALE E WASTE STACK AS INDICATED ON PLANS 2" VENT Y2"CW FROM RISER Y2"HW FROM RISER a EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 Cw/) 0_ CC 0_ 0 ArchitectureSite PROGRESS SET 00 CV J 0 J_ SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. O a) DRAWING TITLE: REGISTRATION: DRAWING #: 246 Walnut Street O co 0 co U, U U) 2 a) C O z CO coCO CO I CO 617 . 581 . 6601 NTS PLUMBING ©TISE DESIGN ASSOCIATES, INC 2019 PLUMBERS WORK TO BEGIN HERE -- GAS METER#1/SERVICE - BY LOCAL GAS COMPANY, NATIONAL GRID TOTAL GAS LOAD 7691 CFH @, 7"WC TEL-300' FROM GAS METER TO FURTHEST GAS EQUIPMENT ON ROOF GRADE j j Gj j FOR RETAILS (FUTURE) 7 ROOF LEVEL 6 LEVEL 5 LEVEL 4 LEVEL 3 LEVEL 2 r6" ROOF LEVEL LEVEL 6 P-3/P3A lJ LEVEL 5 P-3/P3A I - G MECH CLOSET MECH CLOSET MECH CLOSET MECH CLOSET MECH CLOSET LEVEL 1 GARAGE BASEMENT GARAGE (70 CFH) TYPICAL GAS REGULATOR (TYPICAL) GAS SUBMETER (TYPICAL) 1". (70 CFH) G 'STOVE a (70 CFH) -0r4D7am,91,---- G 1 1/4" (120 CFH) STOVE (140 CFH) (70 CFH) 1 1/4-1'"°'°4—G-4STOVE (210 CFH) 0 (70 CFH) 1 1/2'attE0+—G —I STOVE (280 CFH) r) (70 CFH) 2"- (350 CFH) F4" G 0 2"V 2'V P-1 2"W - r 4"VTR 4"VTR -4 STOVE GAS RISER DIAGRAM P2 4"S —. 9- 3'V ju 4"S N 4„S P-1 ir"\ 2"W LEVEL 4 P-3/P3A C LEVEL 3 P-3/P3A U - r P-2 4"S N \ 4"S ✓ P-1 2"W P-2 4"S N \ 4"S r LEVEL 2 P-3/P3A CO LEVEL 1 GARAGE BASEMENT GARAGE P-2 P-1 2"W 4"S \ 4„S PP=1 2"W P-2 j 4"S N \ 4"S 4"S 6"SANITARY SEWER (SEE DWG. P1.0) 4"S 3"V CO --J TYPICAL FOR ALL SANITARY WASTE & VENT STACKS SANITARY SEWER RISER DIAGRAM N.T.S G MUA-1 RTU-1 400 CFH r 2- 3"- 3"-. 3'.-, 180 CFH 2 1/2" G I 3 I BOILER ROOM I GWH-1 GWH-2 G . ROOF LEVEL LEVEL 6 LEVEL 5 LEVEL 4 LEVEL 3 LEVEL 2 r 2"KV 3"KVTR 3"KV I " � I P-4 1 3 KW I r l P-4 2"KV — U r 1 P-4 I U F 1 P-4 I U F 1 P-4 13"KW_p U \ CO `\ ♦• I GENERAITOR TYPICAL 3 BEDROOM UNIT ROOF LEVEL 6 LEVEL 5 LEVEL 4 LEVEL 3 LEVEL 2 MECH CLOSET MECH CLOSET 1"- 1 1/4" —1 1/2" MECH CLOSET w 11 --17 1----1 L LEVEL 1 GARAGE AND RETAIL WC L4 BASEMENT GARAGE WATER METER #1 (RESIDENTIAL) WATER METER #2 FOR RETAILS (FUTURE) 4" f 3" SEE DETAIL— -� ON DWG P1,3 2 1" 2" GWH-1 (TYPICAL 2 BEDROOM UNIT 1" 1' 3/4" 3„ 3 L9, I —3" —1„ —1 1/4" BOILER ROOM I I GWH MOP SINK IN JANITOR 3/4" 3/4"I 1 /2" 1/2" —1 1/4 " 3/4" — 1 1/2" 1/2 — I011 WATER RISER DIAGRAM ROOF LEVEL INDIRECT WASTE FROM FCU TYPICAL 2 I LEVEL 6 > P-5 U— 3„I is-1-1/4" r _ I 2" 4 r — � 3 » P-5 2„ WM ll \i--1 1/2" 3 1—Lr \ I P-5 3" \\1 •_2„ J \ 2" LEVEL 5 LEVEL LEVEL WM X/ 3 " WM X/ 3"LVTR f T 3" J{L P-5 I U I 1410— 2,> 2 WM LEVEL 2 1X / 2" DEEP SAFE WASTE PAN (TYP.) LEVEL 1 GARAGE LEVEL 1 GARAGE BASEMENT GARAGE 4) CON \ 6"SANITARY SEWER (SEE DWG. P1.0) KITCHEN SINK WASTE & VENT RISER DIAGRAM N.T.S } OED 1 Y4" (TYP.) LW \ 1-1/2" 2" SANITARY DRAIN 4" BACKWATER VALVE 6"SANITARY SEWER (SEE DWG. P1.0) BASEMENT GARAGE WATER ROOM S CO I\ ♦ TYPICAL FOR ALL WASHING MACHINE AT LAUNDRY CLOSETS SAFE WASTE PAN DRAIN TO INDIRECT WASTE RISER WASHING MACHINE WASTE AND VENT RISER DIAGRAM N.T.S — 1 1/2" ROOF LEVEL LEVEL 6 LEVEL 5 LEVEL 4 LEVEL 3 LEVEL 2 LEVEL 1 GARAGE 3" r 3" 1" 2"KV P-8 3"KVTR 3"KV JL T„ 3 KW U 2"KV -4 P-8 U BASEMENT GARAGE 6� 1 P-8 U I 1 HU\ 3"KW 1 1 I P-8 I U CO ` \ ♦ L6„ 6"SANITARY SEWER (SEE DWG. P1.0) MOP SINK WASTE & VENT RISER DIAGRAM 1/2" 3/4" CON \ N.T.S 3/4" E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 w UD 0 CC Q_ W 0 ArchitectureSite PROGRESS SET 00 T N 0 J_ SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. 00 O 00 a) DRAWING TITLE: REGISTRATION: DRAWING #: IP) 246 Walnut Street O C.0 N O 11 co a) m ti 0 - CO U) 2 a) C 0 (1) z NTS <i 04 04 41 DO I I PLUMBING 617 . 581 . 6601 ©TISE DESIGN ASSOCIATES, INC 2019 UNIT D1, 601 `CO UNIT D1, 501 {co UNIT D1, 401 {CO UNIT D1, 301 UNIT D1, 201 {Co P-1 2"W P-1 2"W 2"V r N P-1 N _U _U PP-4 r�?i Nr N I P-2 I P-2 4"VTR T . r r _1 N I I 4"S--M 9-2 v I PP=2 I PP=2 N PP=4 4"S ♦ ♦ u u P=4 S ♦ ♦ YrIN r t 1? i N I T N I PP=2 I PP=2 N 2"411\4"S ♦ ♦ ? �? NI NIA I� P-1 F �� �� PP=4 2°W \4"S ♦ ♦ _21 6"SANITARY SEWER (SEE DWG. P1.0) UNIT B2, 603 {co UNIT B, 503 `CO UNIT B3, 403 {CO UNIT B, 303 {co UNIT B1, 203 {CO UNIT T, 606 {CO UNIT L, 506 {c0 UNIT L, 406 {CO UNIT L, 306 { co UNIT P, 206 {CO PP=1 2"W P-1 r 2"V r�NT r PP-2 IPA N r Roof 6th 5th 4"S to .-2"V2nd _J • UNIT D1, 601 {CO UNIT D1, 501 {CO 4th UNIT D1, 401 {CO 3rd UNIT D2, 301 {co UNIT D1, 201 Co 2°W P-3 P-3 r r 2"V 4"VTR 7 I P-2 P=1 \4"S ♦ 2"W \• r--2�1 P-3 2"W - \ ♦ r--2�1 P-3 N PP-1 \4"S ♦4"S NI I P-2 F' N 2"W \• r--2�L1 2°W P-3 ♦ N PP-1 \4"S 4"S- 4 9-2"V PP=1 \4"S _J CO I\ CO` 4"VTR T ?. r r _1 "v I N I 4"S-eg 9-2N I PP=2 I PP=2 N N PP=4 4"S ♦ ♦ 2'Ws r ? r NI I P-2 I P-2 PP-4 P-1 N P-4 2"W S ♦ ♦ r1?I NI N I PP=2 I PP=2 "--U J P-1 2° N yS♦ ♦ rT r �I NI N I P-2 I P-2 P-1 P=4 N N PP=4 r r r 2 \4"S ♦ ♦ 6"SANITARY SEWER (SEE DWG. P1.0) 2"W N P-3 r 2'V NI P-2 —iJ N r--2"1L1 • 4"VTR 4"VTR Roof Roof 6th 5th 4th 3rd Nrted Roof Roof 6th 5th 4th 3rd 4"S— .-2"V2nd _J • Co l� 4MR _1 4"Sir PP=1 \4"S 2"W \• r--2�1 P- N PP=1 \4"S NI I —U F' N 2"W - \ ♦ r- N N I PP=2 PP=3 PP=1 2"W ♦ \4"S r--2"1L1 NI IPA F' N 2"W • 6"SANITARY SEWER (SEE DWG. P1.0) 4"S- 9-2') N PP=1 \4"S CO I` Roof 6th 5th 4th 3rd UNIT A2, 604 {CO UNIT A, 504 {co UNIT A, 404 CO UNIT A, 304 CO UNIT Al, 204 CO UNIT T, 606 UNIT L, 506 {Co UNIT L, 406 r N P-3 2°W N P-3 2"W N P-3 2"W N 2"W P-3 2°W P-1 • r--2�L1 2"V r--2�1 PP=1 — r ♦4"S 6th • N PP=1 \4"S r--.2:L1 • 5th ♦4"S 4th NI I N \4"S PP=1 • r � i r N NIP-2 IP-2 N 2"W 4's ♦ • 1?1 NI N I P-2 I P-2 P-1 N 3rd 1`_ 4"S-40 *--2"V 2nd _J ♦4"S r CO\ 4"VTR RdRrfof _L _, 4"S -10 9--2"V P. N P-4 YrIN 2"W 4"S CCO r1YT r r ?-1 NI N N I PP=2 I PP=2 �J —� N UNIT L, 306 PP-1 c. N PP=4 21 \4"S ♦ ♦ P. „ , x —` , u u p-,, 1 L Co 2nd UNIT P, 206 4, 4 6th 5th 4th 3rd UNIT C2, 602 �CO UNIT C, 502 �CO UNIT Cl, 402 �CO UNIT C, 302 CO UNIT Cl, 202 �CO UNIT A2, 604 co UNIT A, 504 �Co UNIT A, 404 �CO UNIT A, 304 �CO UNIT Al , 204 Cu) UNIT T, 606 �CO UNIT K, 507 �CO UNIT K, 407 �Co 2"W 2"W 2"W 2"W 2"W P. N PP=1 2"W P-1 r r P. N P-3 2"V 1 NI N 2.2 PP=1 —u ✓ - 4"S♦ r 2v r 1 I P. �NI 1 N P-2 NI '—u Pi P-3 P-3 N P. N P. N 2°V -7-1-• 4"S♦ r--2'1L � 4"S 1 1 i 1 ?1 NI PP=1—u - 4"S♦ r 2"V r 1 ?I ? NI �—' -7-1-• 4"S♦ r--21L—r P. N T 1 i N I4"S- �N 2.2 —u P-11 4"S _J CO r 1 NI ? NIPS I P=2 P-1 N 2'W \4"S ♦ ♦ �-1 2"W P-1 2"W 2°V r r-2 P. N 1 P. N ?1 Nr N I PP=2 I PP=2 PP=4 4"S E' P. N P-4 r t r p. N • CO N N IPA 4"S • p.1 NI I P-2 2"W 4"S • r1�L PP=1 UNIT K, 307 2"W CO r T + a YrIN EA YrIN 2nd P-1 UNIT P, 206 I P-2 • • • CO CO 6th 5th 4th 3rd 2nd Roof 6th 5th 4th 3rd UNIT C2, 602 {co UNIT C, 502 {CO UNIT Cl, 402 UNIT C, 302 CO UNIT C1, 202 UNIT A2, 605 UNIT A, 505 UNIT A, 405 CO UNIT A, 305 CO UNIT Al, 205 CO �r NIi2 N 4"S ♦ 2"W F' 2"V ✓ P. N 17Y- I PP=2 N 4"S ♦ 2"W r N1 P-2 F' I P-2 I P-2 • P_4A • 2"V Roof Roof 6th P-3 UNIT B2, 603 2"W 5th P-3 UNIT B, 503 4th UNIT B3, 403 P-3 2"W 3rd UNIT B, 303 P-3 2"W 2nd UNIT Bl, 203 Roof 6th 5th C CO UNIT A2, 605 UNIT A, 505 4th UNIT A, 405 3rd UNIT A, 305 2nd UNIT Al, 205 Roof Roof 6th 5th 3rd 2nd UNIT S, 607 CO UNIT K, 507 CO UNIT K, 307 CO UNIT N, 207 CO 4"S • 2"Vi 7--L- \ P-2 6th 5th C CO UNIT S, 607 UNIT K, 508 CO 4th UNIT U, 409 3rd 2nd C CO UNIT K, 308 P-1 C CO CO -7-1-• 4"S • r 2"17, \ 4"S • • • • • 6th 5th 4th 3rd 2nd LEVEL 1 GARAGE BASEMENT GARAGE Roof 6th 5th 4th 3rd LEVEL 1 GARAGE BASEMENT GARAGE Roof 6th 5th 4th 3rd LEVEL 1 GARAGE BASEMENT GARAGE EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc (,m, ALL RIGHTS RESERVED CD 15) uD CC ArchitectureSite PROGRESS SET 00 SCALE: 0 SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: DRAWING #: 246 Walnut Street • CO CV co oo 0 - CD CD co 617 . 581 . 6601 NTS DIAGRAMS -A rn 14-1 SANITARY PLUMBING ©TISE DESIGN ASSOCIATES, INC 2019 UNIT R, 608 `co UNIT H, 509 `co UNIT U, 409 `co UNIT H, 309 I co UNIT M, 208 COl UNIT E2, 611 I co UNIT E2, 512 I co UNIT E2, 412 I co UNIT E3, 312 ICO UNIT F, 210 ICO r r r YriN 2W _)4"S \ \ r T r N "IPA I P-2 P-1 —u —u C-1- 2W \4"S \ \ 6"SANITARY SEWER (SEE DWG. P1.0) P_1 r r 2v TI N I P_2 Tr CV Ifs 2W \4"S \ r� NT N�- P-2 I P-2 T P-1 P N N N r T N 2v T TI NI I P-2 I P_2 2w a•s \ \ r - T r T N P- TI NI "IP2 IPA r 2"W \4"S \ r TI CV " I F2 I PP-2 P-1 —Li —Li 2"W 4"S \ r2T p. r TI N1 " I 22 I P_2 P-1 N 4"VTR 1 Roof 6th 5th 4th 3rd -44 4"S---0 -2 V 2nd T N 2"W _4"S \ \ TrJ?I NI N I P2 I f 2"W 4'S \ \ pT Nr " 1 P-2 I P=2 CO l\ 4"VTR Roof r 4"S 4P---2V 6th r 5th r r 4th 3rd YrN PP-1 P-4 27/ \4"S \ 6"SANITARY SEWER r 4"S—� �v 2nd -J UNIT R, 608 I Co UNIT H, 509 la) UNIT U, 409 CO 2W 2'W 2"W P-3 P-3 UNIT H, 309 P- CO UNIT M, 208 CO UNIT E2, 611 ICO UNIT E2, 512 `co UNIT E2, 412 `co UNIT El, 313 ICO 2W P-3 2"W 2V 4MR 1 -r -1 ? 4"S-0 ♦"V -2 N —I J P-1 N TI NI —U P A. r--2-"V_1 r--2�1 r \-7-I4"S \ 4"S \ 1 N . 7-1-\4"S 2v 2.1 \,4'S 2W �� 4"S \ r ZY NI " I P-2 P-1 N 2141 4'S \ r P=1 21V 4"S \ r 2"W P-1 P N 4"S \ 4"S- 11-2"V co 4MR • 1 4"S--0 4P- 2 V 4"s--• 11--2"V _J CO I\ \ CO (SEE DWG. P1.0) Roof 6th 5th 4th 3rd add Roof 6th 5th 4th 3rd 2nd \ UNIT G2, 609 I co UNIT G, 510 CO UNIT G, 410 I Co UNIT G, 310 CO UNIT G1 209 ICO UNIT Fl, 610 Ico UNIT F, 511 I co UNIT F, 411 I CO UNIT F, 311 ICO r PP-1 2"W 4"S \ 2v 2"W 4"s \ r 4MTR Roof 6th 5th NI " I PP-2 P1 P J N 2"W 4"S \ r 2W 2"W P_1 P-1 2"W r T N zv r�—T P-1 T N 4"S \ r 1 TI 4th 3rd " I P-2 P-1 N T T,1r " I P_2 Ii 'L-2 P-4 4'S \ NI P-2 NI I 4'S \r TI CI " I P=2 I P-2 ♦ " I P-2 TIN 4"S \ r r r r i 4'S—an 9-2"V 2nd CO \ 4vTR Roof 4"S--0 N UNIT F, 210 P-1 CO 217/\4"S \ \ r 6th 5th 4th 3rd • —j 4"S-0 ~2v 2nd CO\ UNIT G2, 609 ICO UNIT G, 510 ICO r 2V TI C•1r "IPA IPA 4^S \ r- T N r IJ2 If2 4"S \ r TI NI " 1 P-2 I f2 UNIT G, 410 P-1 PA 217—\4"S \ \ 1CO r2V_ r T NI "1 N IP2 If_2 UNIT G, 310 P-11 —u —u 2W 4^S \ \ 1CO r 'T Tr T 1 "I " 1 P-2 UNIT G 1, 209 P-1 ---U --U CO UNIT El, 612 ICO UNIT El, 513 ICO 2W — \4'S\ \ 2v Pi 21,1 P-1 r T N r�N- .r I P=2 I 2=2 r r r r 4"VTR Roof 6th 5th TT N r r Ii_2 IPA P4 YrIN4"S \ \ z'w a^s \ rr TI "I " I P-2 I P-2 N 4th 3rd • j Y 4"S- �v 2nd -J co 4"VTR Roof 4'S-0 4P- 2v P-4 UNIT El, 413 P-1 P " P-4 2'W 4^S \ CO rT p.r P.- " I P=2 I P-2 T UNIT El, 313 P-1 r r YrN r 6th 5th 4th 3rd I 21W 4"S \ J 4"s , �v 2nd _J co \ LEVEL 1 GARAGE BASEMENT GARAGE UNIT Fl, 610 ICO UNIT F, 511 COI UNIT F, 411 CO UNIT F, 311 ICO UNIT F, 210 P-3 7-1--\ 4"S • 7-1"-\ 4"S \ CO Roof 6th 5th 4th 3rd 2nd LEVEL 1 GARAGE BASEMENT GARAGE EDE INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc (-F.,-ALL RIGHTS RESERVED CC Lij co L-13 CD IL FL)) PROGRESS SET SCALE: LU LLI 0 Cn F— URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. MAR 22,2019 BUILDING PERMIT SET DRAWING TITLE: REGISTRATION: DRAWING #: CV co co c • Co 1.0 CO N- NTS rn cn PLUMBING ©TISE DESIGN ASSOCIATES, INC 2019 6" F _ 0 — 4» NOT:L� ALL PIPES J9 II I INVLIN-11.96 — — I�- 4"GW — CONTINUATION BY CIVIL ENGINEER INV.EL.= 12.00 :GD INV.EL= 12.00 6 S BLD0UT INV.EL=12.15 4"W&T S B — SCAL_ BAST- V 01/8" BE—CA-ST IRON IN —THE BASEMENT AREA 6"S UP INV.EL= 14.00 6S- INV.EL=13.76 4" r6"S 2'V STAIR 1 Si E- UP �4"GD UP INV.EL=12.8 BELOW EL. ROOM IN\.EL=12.45 3 BELOW EL. ROOM 1 2'V UP—� \T FLOOR P 1' ^ 99 r4" 6"S DROP NCO INV.EL=12.22—/ A\ GD fT� =__= F==-= W E4JB MENT CLG CO 4"W&T I_J —4" BELOW SUB BASEMENT CLG c v � 4"W&T GAS —OIL INTERCEPTOR ABOVE SUB —BASEMENT FLOOR ON CONCRETE BASE (SEE DETAIL AT DWG P0.2) GC L —d NOTE: PLUMBING DETERMINE FOR GWP— \16 3" CONTRACTOR qt THE LOCATION 1 ON THE FIELD GWP-1 SEE CHE_DULE ONLP FFE=4.6 4" • Z 0 0 z CO 0 Ca L BELOW SUB BASEMENT CLG FM CO (I) — 4"-WacT —4'' 2"FM UP 2"V UP BELOW SUB BASEMENT CLG A re W&T !CO INV.EL=1 8 N (Th E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 -• E C) <co (3 o � • 2 VD Q O C 0_ VU CD 11L n z 15) = U Q JL PROGRESS SET W Q SCALE: PROJECT#: URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. BUILDING PERMIT SET 0 CU DRAWING TITLE: REGISTRATION: DRAWING #: co CV O CU L C) co 22 CU 2 co O N .1- Z • Co Li') CO CO Lf) N- 1"=8'-0" z a 0 0 SUB -BASEMENT PLUMBING ©TISE DESIGN ASSOCIATES, INC 2019 4" r 4"DOMESTIC WATER SERVICE TO BLDG 6" FIRE SERVICE TO BLDG r L BAS SCA L 4" W &T FCO 4" 6"SS DN 4"W DN FROM 4"FD—B IN TRASH ROOM 99 2"V GD STA S1 FCO 2"V 4"GD (SEE P1.0) R 1 [L 4"GD DROP J 6"S DN ER LOBBY B01 ELECT ROOV 302 RICAL 4"GD (SEE P1.1) 6"S • Q0 0 z 0 0 cn 0 co 10"COND DROP — 4" GD II] 6"S (2)4"V 4"V \-10"COND (13,804 SQ.FT) 0 BELOW CLG 10" BELOW I CLG 0 z 0 0 I-10" L 4„ GAS —0 INTER (SE 8"(9,353 SQ.FT) RD INV.OUT= 1 6.72 (SEE SITE PLAN) 15.89 GD I -b L BELOW CLG 4"W&T LOW PTOR DWG PO.1 SB) 0 SQ.FT) ER GARAG B05 FFE=15.79 re- 1/8" 9-0 NOTE: ALL PIP 2'V GD co BELOW CLG \-b 4"W&T II] 5"COND (2,951 SQ.FT) 5" CONC "FD (200 &T SQ.FT)W FFE=15J9 S TO BE CAST IRON BELOW BASEMENT CLG FFE=16.05_k Ico 3"W&T (3"FD—B) (6,102 COND SQ.FT) 3"W&T (3"FD—B) 5"H-- u z 0 0 2"FM FM FM 2"FM 2"V UP 5"COND (2,951 SQ.FT) 4"F E=15.83 r5"(3,151 SQ.FT) CONC CO- N 0 z O 5'= ti z 0 0 E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 JL w UD 0 C= 0_ ArchitectureSite Planning Project Management PROGRESS SET 00 CV SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: DRAWING #: Ppl 246 Walnut Street X O � O NCO O • L• C) • ti 0 - CD CD co ca a) C 0 z 617 . 581 . 6601 12_8,_ON z a 0 0 ©TISE DESIGN ASSOCIATES, INC 2019 L C CA TRASH ROOM 104 4"FD—B 1 FD FD 99 DI 106 V. _OBEY J V TSTIBU 101 L Roby U- I I LOBBY 102 �3"FD—C O 3"FD—B 1 / 32 CHURCH ST. //////////////////////////// //////////////,//////////// -TAIL 107 11 4\ EXISTI\G BU IUD \G -C 0 O 3"FD—B / FD 1 1 L 0\ S 1 I I I I I I I I 1 321 I I I 4 4 4 4 I— I1 UP L N E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 w C/D 0 0 CC 0 W PROGRESS SET CO i u U F SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: DRAWING #: 246 Walnut Street i"=8'—ON z 0 0 w H PLUMBING Ppl DI ©TISE DESIGN ASSOCIATES, INC 2019 H 3/4"CW DROP TO HB MOUNT SHUT—OFF VALVE 5'-0" ABOVE FLOOR TO HB - (TYPICAL) \I 4"BFP 4"CW S`'—VICE TO BLDG 6" FIRE SERVICE TO BLDG L4 3"LS 2"LV 1 Y2"IW 7I I K6 1 4"KS 3"V 104 3 GAS METERS IN RACK #1 GAS METER (GWH, RTU-1, MUA-1, STOVES) #2,#3 GAS METERS (FUTURE RETAIL AREA) L V SCA L 5"COND (2,951 SQ.FT) V B3.2 4"SS 3"V LW IW B4.1 4"SS 13"V K5 4"KS 3"V I L6.1 1 Y2"IW 3"LS 2"LV B6.1 4"SS 3"V FD /8" CO 4"SS 3"V CO CO odd IW LLW C LW �o L 3" 4" s 4"SS 'CO 3"V 4"KS 3"V a 5"CONp'� (2,95 SQ. B4.21 4"SS 1IM5 2"GAS 2"CW - IW LW LW ®— 5" COND I (2,951 SQ.FT) p Q 8" .v) 0 4" CO 1 5.21 IW 3"GAS FOR 3"GAS UP 3"CW UP 2"GAS 2"CW po GENERATOR 2/4"CW UP 4"KS (2,000 SQ.FT) 3"LS 2"LV Irss OR FIRE PLACE 6"SS OE CONIC EV. LOBBY RAM CO AEA 3/4"— (-00 SQ.FT) CON C 106 2"V—\ \,1 • 3"LS 2"LV M6 CW CZ I L7 CO 4"SS 4"SS 5D (2,951 SQ.FT) FD ONC 4"KS CO 0 / (400 SQ.FT) ri CO 1 Y2"IW 2"LV 4"SS I M7 I 2"GAS 2"CW 3"LS 2"LV 2"GAS 2"CW ITAIL 4"SS A S 2"V 32 CHURCH ST. ILD ////////////////////////////1[1:///////////////////////////A LW 4"SS "IW 2"LV SS CW [6" [4" 2"GAS 2"CW _;:// 2"GAS 4"KS 5"COND 3"LS 2"LV 1W \ f 2 ° \ I K9 I 4"SS GAS CW 3/4 CW DROP TO HB MOUNT SHUT 0 LVE 2"C FD LW UP 5"COND (2,951 SQ.FT) 4"SS IW 4"KS L1J EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc r,Th., ALL RIGHTS RESERVED UD CC CL ArchitectureSite Planning Project Management PROGRESS SET 00 CNI SCALE: 0 SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. co co DRAWING TITLE: REGISTRATION: DRAWING #: 246 Walnut Street co co -41 co co 0 zI PLUMBING CO CO CO 00 LO CO 617 . 581 . 6601 PIDIC ©TISE DESIGN ASSOCIATES, INC 2019 RD B1 \ I20�5 I I L4 I 3"LS 2"LV �y2)lA' 204 I1K4I 4"KS 3"V 11 K6 I 4"KS 13 "V Immo 1 3"LS 2"LV 5"COND (790 SQ.FT) AI4K S 1 3"V I B3.1 1 4"SS 3"V Il II I I II Ili DW . 3.2 "SS K3 ter I L3 1Y" 2 3"LS 2"L aka I .1/ I 4"SS 3"V M3 I HW CW It IL--- II II 11 205 DW Win P 206 3 ANT B1.1 1 4"SS 3 "V 7 b M5 1 HW CW OW GAS I Iit 111 II 11 6-0 ND 90 —SQ. I '•21 P 0 9 O O Atm I B2.1 I 4"SS 3"V K2 "KS L2 I 1 Y2"IW 3"LS 2"LV 1 "CHW raL W/O C1 AFFORDABLE 202 I B2 I 4"SS 3"V If M1 '1 CW AS r JQ • ow ' O o M4 HW GA'S �r1"CHW get "II- Li Li- VH L C SCALH 0 1 /8"' RD I L6 I 1 Y2"IW "LS S T AS TO2 Li I D AIR 1 UP I" CW _GAS 1 I 201 �f SUP/DID 3"GAS UP/[ NJ 3"GAS FOR GENERATOR 1 "CHW DN I K1 1 4"KS 3"V ELEV. T I 2"V D AT I II 1 B2 4"SS CLO �L " T05 I: — — — -I i1 M7.11 I HW I L7 I 1 Y2"IW 31'LS 2'LV 1 99 PITCHY PER RF /v E 3"FD- D OOT 0 3"FDI- PITCH PER FOOT PITCH Y4" PER FOOT PITCH Y4" PER FOOT RD .B 1 3"FD-C 3/4"CW DRC AD \ MOUNT SHUT OFF VALVE 5'-0" ABOVE FLOOR TOI HB (TYPICAL) Y4" PER FOOT 3/4"CW DN N 3"FD-D 0 • • 3/4"GAS FOR FIRE PLACE COMMUN 211 1 B12 1 4"SS 3VI M121 HW CW AS V 3/4"CHW 4"V J V 0 1_ 1 K121 4"KS 3"V \� L12 I 1 Y2"IW C 3-LS TO1 2" L\' 3/4"CW DROP TO HB MOUNT SHUT-OFF VALVE 5'-0" ABOVE FLOOR TO HB (TYPICAL) 5"COND/L (2,620 S9.FT) B7."f I O iJ'SSI U B E ITV / \ / \ \' 1 K7 I \ E , / 4"KS 3 V � BEN ;v BE OW i i i N L7.1 1 Y2"IW 3"LS 2"LV 3"FD-D L7.2 1 Y2"IWI L �t� "LV 0 \-3/4"CW DN NNECTION AT THE BOTT 0 OF HW RISER. PROV CIRCUIT SETTER. SEE /LARGE UNIT PLANS —F-OP.-1,_1IINUATION AND GIZE-� Y . 13j, 1 B 1 1 1 4"SS 3"V 11. Mu 1 �CC� N AFFORDABLE 1207 I OP OD II CW GAS I 3v W/D M 10 HW low GAS 1 II M8 1 HW CW \ 1 rt�REF B8 l-"SS "V O 0 I K10 1 4" 3'Y 210 4"SS 5"COND -I 191 1 3"LS 2"LV DW RD di 4"SS -TLft W/D 208 9 RD I K8 MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED u21 121 up Project Management co PROGRESS SET CO SCALE: PROJ ECT#: LJ —J F- 0 w MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: DRAWING #: CD CD cn CO CO CD CO CO N- cn PLUMBING P1.2 ©TISE DESIGN ASSOCIATES, INC 2019 I 303 I L4 I 3"LS 2"LV 1 )'2"IW A 304 I K4 I 4"KS 3"V 1 B4 .2,I 4"SS 3"V I B5.1'1 4'jSS L 3- I B3.1 4"SS 3"V DW L —1 M3 I HW o a I L5 1 Y2[W" 3 ' A 305 K6 1 4"KS 13"V L SCAL I K5 1 4"KS 3"V L _ 0 L6.1 I 1 Y2"IW 3„LS L1 B6.1 1 4"SS 3"V Jl)6 K3 I "KS 'V —� 00I I' L a� Imo_ 3 " -; REF ..y 2" DW - ii 5"COND OW 99 M5 I HW C GA I B2.1 I 4"SS 3"V L2 I 1 Y,'IW 3"LS 2"LV I B1.1 4"SS 3"V I M4 I HI' C STAI R UP TRASH T02 \/ M6 HW CW L6 I 1 Y2"IW 3"LS 2"LV S1 C 302 B2 1 4"SS 3"V 3"CW UP/DN 3"GAS UP/DN 3"GAS FOR GENERATOR 1 "CHW DN I M1 HW CW GAS D2 AFFORDABLE 31WK1 4"KS 3"V L1 2"IW 2"LV �B1.2 4"SS "V DATA CLOSET T 1 I B1 M12 CW j ij GAS L7 REF 1 4"KS 3"V 1313 1 DW 1111 I I L12 1 Y2"IW —3"LS I B11 COND M7.11 HW o CW GAS I K7 4"KS 3"K 4"S 2"V C RRI C I L7.1 I 1 Y2"IW 3"LS 2"LV (2)2"V rr I B10 1 4"SS 3"V I— 1 B10.1I 1 4"SS 3"V 1 I 4"SS \I 3'''V- Tkl 1 9 �I �I Q REF HEF:11 /g11 HW CAE, I M9 I HW CW AS REF I I I I I I I I AFFORDABLE A I1 1 I 1 Y2"IW 3"LS 2"LV ,11 OW L7.2 1 Y2"IW 3"LS L LV M8 "SS V B8 I 4"SS __ JJ B9.1 / 4"SS 3"V I "cp ND I L8 I 1 Y2"IW 3"LS 2"LV 309 H F K9 4"KS 4"KS 3"V E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 w CID 0 CC 0 PROGRESS SET CO SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: DRAWING #: 246 Walnut Street C0 C0 CO ti (0 1N_p'—ON PLUMBING P)1.3 ©TISE DESIGN ASSOCIATES, INC 2019 r- \ B3 403 I L4 I 3"LS 2"LV 1 Y2"IW A 404 L C I K4 1 4"KS 3"V B4 4"SS 3 "V I I B5.11 4"SS 3'v L A 4054�5 I K6 I 4"KS 3"V i L5 3' 2' I K5 4"KS 3"V w3 O O I L6.1 I 1 Y2"IW 3-LS 11\ I � I B3.1 I 4"SS 3"V L — I B6.1 "SS V 406 V/D OW I 5"COND OW I S5'.2I —VI—L 4 CA He1/8"-1' I B4.1 4"SS 3"V 99 M5 I HW C 4"SS L2 I 1YAyy_ 3"LS 2"LV L STAIR` UP TRASH IT02� \ / V I M6 HW CW _GA _JI I L6 I i Y2"IW 3"LS 21"IILV I — r— -- —iu 1' Cl AFFORDABLE 402 I B2 I 4"SS 3"V I M1 HW CW GAS 401 3-OW UP/DN 3"GAS UP/Dr 3"GAS FOR 1 _ GENERATOR 1 "CHW DN L1 "IW /B1.2 1 4"SS "V I,1 DATA CLOS Tn� / I B6.2 4"SS 3"V T IB12 SS I M12 I1 1 /HW I I B11 CW + 4"S j GAS ( ) ow 12 "V a. I L12 I 1 Y2"IW 3"LS 3"Ca 1 B7.1 4 'v L7 2'L' I~ I __f M7.1 HW CW GAS I K7 I K3"KS "V 407 >< °ID I L7.1 1 Y2"IW 3"LS 2"LV I K11 1 Y2"IW 3"LS 2"LV II I REF li P I Li 1\Y2" 3"L 2"LV op ob 1I11 4"SS 1 I B7.1 HW CW J AFFORDABLE 408 B10 I 4"SS 13„ I L10 1 3 2"LV I B10.11 4"SS 3"V pi I M10 I HW CW GAS I M8 / HW CW r'�.S_ I 3 1❑ REF 4 04) 7 __ JJ I B9.1 I 4"SS COT L9 III 1 Y2"IW „L F 411 ow I JJ "CDIN D II II Y2"IW Y2"IW 3"LS 2"LV ti I K9 I 4"KS I 4"KS 3 409 U i 2 IB8.1I I>< / 4"SS 3"V 0 K8 4"KS rJ 3"V ¶ 1 1 E E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED (Project #: 4017 IL a) E 0) a) U a) ^L I.— 0) a) a) lE U = U w CID CC PROGRESS SET CO LLI UJ 0 z la2 CO < (1) (0(1 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. To DRAWING TITLE: REGISTRATION: DRAWING #: 17 1 co cn cn co co CO CO CO CO CO co o al PLUMBING ©TISE DESIGN ASSOCIATES, INC 2019 I _ r B 503 I L4 3"LS 2"LV 1 Y2"IW L A 504 \ A 5�5 505 L� I K6 I REF L V SCAL 4"KS 3"V K4 4"KS 3"V I B4. 4"SS 3"V B5.1 4"SS 3"V L-= I B3.1 4"SS 3"V DW L = — r 00 L 1 3"L 2" 3 '' S I Q _ ! K5 I 4"KS 3"V I L6.1 1 Y7"IW 3"LS L _ 506 5"COND 0 8 ow -0 T 5 01/8" 19 99 REF I B4.1 4"SS 3"V J I M4 HW CW CA L6 3"LS 2"LV 502 2"LV 4"SS 3"GAS FOR GENERATOR HW CW GAS 4 STAIR UP 501 Li I 4"SS L7 "LV Hyv GAS I K7 4"KS KV 507 11 3"LS 4"S 3"LS M7 HW CW GAS DW 508 4"SS 2"LV 4"SS CW JAN CW GAS d 1— HW CW AS 1-LJ DN 3"LS 2"LV DW 4"SS 509 4"KS 4"KS I K8 4"KS EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED Project #: 4017 CC PROGRESS SET CO coc co SCALE: 0 SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: DRAWING #: 246 Walnut Street CN 0 rxl PLUMBING Ppl .5 CO LO CO LO ©TISE DESIGN ASSOCIATES, INC 2019 -\ I IK3Ta 4"ISS 3' I B4.1 4"SS 3"V A2 604 4"VTR B3.1 I 4"SS 3"V /D 4"VTR 5"COND ICI HW CW I K4 II DW 4"KS \ i'��--- I 3 V I B4.2 4"SS B5.1r�� 4"SS - 3 "V �— 1 3"LS 2"LV 4"VTR 4 A I K6 4"KS I 3"V L V VVA L 605 I_ CAN 3"V I \L6.1 2 LV I � S 6 /8 /D B6.1 3 3 606 , 3"V I K2 C2 602 HW— CW GAS tVcr- 3"GAS FOR 4''SS GENERATOR M4 TRASH I M6 I HW CW L6 I 3"LS 2"LV SKYLIGHT I El 1 • HW CW GAS 4"D 1 3" 'GAS UP CI GENERATOR 3"GAS UP 3"CW UP 3"HW UP LS "LV VTA LOSET ELEC. 4 3" 2"LV HW 1 4"SS DW 3"LS 2"LV 4"SS F 1 2 C14( EQ 1608 hi EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED rf CC PROGRESS SET CO SCALE: 0 SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: DRAWING #: 246 Walnut Street co CN co PLUMBING P)1.3 CO CO CO CO CO CO ©TISE DESIGN ASSOCIATES, INC 2019 R00 SCA PITCH 1/4" PEIR FOOT 4"VTR 0 4"VTR PITCH Y4" PER FOOT I � 5"RD (2,951I I4."VTR h I I ""VTR A\ / 8 " 4"VTR \ •f 5"-D 2,951 SQ.FT) 99 4"VTR PITCH Y4" PER FOOT 3"FD—B 0; 0 L 0 w 0_ 4 "VTR -EEECTR C ROOM 2 R04 3"GIS DN S='CW U1�1- 3 HW DN ice" CHW DN ENERA • (2) 119 GALLON TANK MODEL BY LAARS HEATING COMPANY (SEE DETAIL AT DWG P0.1) ELEV. VAC INE ROOM 02 PI TC(12)4 (URE' FOOT S (2)2"V 4"VTR 5"RD 951 SQ. nTh,p /4 i'LI-< FOOT FT) A0070101, 7 4"VTR L 7-1 EL •- 4"VTF 4"VTR LV [] ir PI TO *WI /4" PER FOOT /1 4"VTR 4"VTR J 7 Y4 PER If Ou 4"VTR 5"RD (2,951 S/FT) RD PITCA_Z" P� FOOT RD LV • iI 5"RD (2,951 SQ.FT) PI 01-I1Y4" PER FOOT 4"VTR V • • S D1 A\ E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 0 0_ CC 0 W 0 ArchitectureSite PROGRESS SET 00 CV SCALE: PROJECT#: SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: DRAWING #: 246 Walnut Street O 0 co U, L CO co 2 a) C O a) z CO CO CO 00 I CO 617 . 581 . 6601 1"=8'-O" z a 0 0 PLUMBING P)1 .7 ©TISE DESIGN ASSOCIATES, INC 2019 SF - r- SEP SF'n SF BEDROOM M5 SF SF SF SF V B CD I R LIVING/DINING M3 B MASTER BEDROOM M9 D BEDROOM M5 SCALE: 1 /4" = 1 B il— I IL —_ I LAUNDRY 3�4"CW,HW&CHW M7 I I IE WA IN CLOS M8_ � c MASTER BATH NAF LAUNDRY ._ 4"HW&C1r BR RUNNING 2"V & W A UNDERNEATH LIVING/DININGFLooR M3 B MASTER BEDROOIv M9 D BEDROOM M5 Tv' 0'' CAL 4"KS 3"V \ Y2"HW & Y2"CW RUNNING 1. NDERMEATH F _OORWA LL KITC M2 1"G DROP - EN MASTER BAT II WALK-IN II CLOS TYP. M8 BEDROOM 1 "G DROP r� D SF c---' 4"SS 3"V MASTER -1 BATH D P-2 ,D6 T".HEN tv.2I P-4 LOW —1»G "G SUB—METER-- 1"G SUB— ER 3/4"HW&CW 1"G SUB —METER. 5"COND LAUNDRY ALL T 4"K 3"V C /� M1 I _- I C - v. WALK-IN Kai En A TYP. LK -IN_ bLO, M8 MASTER BEDROOM M9 C 2BR LIVING/DINING M3 � II M2 /4„HW 1 Y "CW 1 Y "GAS 1"G DROP _ Ki sir 3/4"CW&HW ,KITCHEN 4"SS P-3 B1.2 4"SS T PLA\ C T"PF-- — A, E3, C 8c D BEDROOM M5 D MASTER BEDROOM U9 B D2 �BR AFFORDABL LIVING/DINING U3 A TYP. B B SF BEDROOM U5 J G B -,- D BEC M5 L F— it SF SF SC SF BED POOM "G DROP LAUNDRY IB3.11 4"SS I— II ATH L. BEDROOM M5 II B B1 LIVING/DINING M3 MASTER BEDROOM M9 SF II BEDROOM M5 SF B L4 I 1 Y2"IW 3"LS 2"LV Pf WALL W CLOS M8 FURNISH & INST ALL ASTE & Y2"HW NECTIONS TO W WITH STOP VALVE MASTE BEDROOM BEDROOM WALK-IN iI CLOS TYP. A2 HALL 1"G DROP • 1"G SU —METER 1"G SUB —METER P-4 -11 WALL 2 ALK-IN C OS BATH M8 I LAUN DYILL SF A2 0 T A TYP. MASTER BEDROOM Cl AFFORDABH ROP CLOS BEDROOM MASTER BED (1)0M DI A TYP. BEDROOM EDE INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 COPYRIGHT 2015-EDE Inc tr--.-ALL RIGHTS RESERVED up LIU (13 CD 46 0 EL Fo CD LE PROGRESS SET oo SCALE: co MAR 22,2019 BUILDING PERMIT SET CO CD 71- CO 1-3 CD tf5 CO CO CD CO I CV 0-1 cv- 0 CD REGISTRATION: URBAN DRAWING #: DRAWING TITLE: P2pf ©TISE DESIGN ASSOCIATES, INC 2019 5F I I SF SFSF BEDROOM M5 B B2 SF SF SI� JB R LIVING/DININC M3 B MASTER BEDROOM M9 SF D BEDROOM M5 i P-T II (p, AM4� P-3I IUD I IU I / 3/4"CW&HW 1"G DROP I K3 I 4"KS LOW PP—. WALL FURNISH & INSTALL 1 "WASTE & Y2"HW CONNECTIONS TO DW WITH STOP VALVE 2 2BR WA CLO M8 LAUNDF, M7 LAUNDRY M7 B —IN_ IF II fTYP. FCLOS %"HW&C 0 KITCHEN M2 3/4"CW&HW A2 MASTE BATH AA G, Y2"HW & Y2"CW -ma a II RUNNING UNDERNEATH FLOOR 2"V & 2"W RUNNING UNDERNEATH FLOOR LIVING/DINING M3 B MASTE BEDROOM M9 D BEDROOM M5 PLJVB \C T"P SCALE: 1 /4" = 1 — 0" CAL NTH "HW&CW 1"G--....,. ^4I II; KITCHEN F-6 I I,_ _ M2 I I o P-5 ! I I C� II 0 C _J „ BEDROOM M5 - n P—E, _ LOW c', dVALL LAL\ND L i HALL 'CW w P-3 C B# _1— ---C`—�F—S F HAIL_ I_— M v1ASTER BEDROOM M9 B C2 7BR LIVING/DINING. 1"G I(� MM� "G DRY BATH K—IN , CLOD I TYP. M8 T P J BATH A\S T" M4 D P 2 I „ inc ( A' 2 3 STER CW UP/DN TF 3"GAS UP/DN 1 "CHW DN o A Tlr'11\-2""T . 1 Y4"HVy B7.1 I I 4"SS 3"V M3 B SF SF D MASTER BEDROOM_ U9 C P-6 D P A?, B 2- 8c C2D 400 --"G DROP O 4'KS 3"V c-4 \ 1( SE SF 1 I L_ J STUDY P-4 KITCHEN M2 P-5 PL VB \G �\ SCALE: 1 / L" = 1' 99 A2 1DRY M7 2BR LIVING/DINING. M3 ' IF B SF i SF BEDR00 M5 SF SF D g F CLOS F B3 BR U3 SF BED 001V M5 VVAI MASTER CAL MASTER BEDROOM M9 1"G DROP / LOW P-4 • WALL SF SF CD MASTER BEDROOM M9 BEDROOM M5 1"G SUB —METER CLOS KIT -3HEN_ LL CLOS BEDROOM M5 ASTER / BATH ( SF A TYP. 2 BR U3 MASTE BEDROOM Cl LAUNDRY RUNNING LIVING /DINING. M3 SF CLOS M8 SF SF BEDOOM M5 SF MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED fiE F— LLJ cn Up UJ CL- 00 SCALE: —J UJ 0 CnD < Ulu) MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. co CN DRAWING TITLE: REGISTRATION: DRAWING #: CD co CD Caw CO SD o Z co aci 1-1 P2.2 ©TISE DESIGN ASSOCIATES, INC 2019 SF J I zI 7 I 7 I J BATH ,/14 1 D E3 AFFORDABL 1BR LIVING/DINING U3 0 U EEC CLOS r_g_ I B11 4"SS 3"V U4 WALK—IN CLOS ROOM P SCAL VB 1 CLOS BED U5 LIN KITCHEN U2 L11 1 Y2"IW 3"LS 2"LV -1 "G SUB —METER AUUNDRY I II ROOF \C T"P A G J\ K1 1 P-6 BEDROOM U5 MASTER BEDROOM U9 D MASTER BEDROOV U9 • II KITCHEN P-4 U2 r1„G . G K 7BR LIVING/D NING U3 - • T P LA \ B T"P B10 2'VJ-i 2"r&T �f Y2"CW—DROP TO ICE MAKER WITH STOP VALVE tL10 1 Y2"IW 3"LS 2"LV z D WITH STOP VALA TO ICE MAKiEF WALK— N CLOS RAT P-1- 3/4"HW \ CLOS V ASTER BEDOOM U9 4"SS r4"S P K10 41< U2 FURNISH & INSTALL CONNECTIONS T DW WITH STOP VALVE P-7 p, Y2 " 0 ( I L9 1 Y2"IW 3"LS Y2 "GAS V ASTER 4"SS P-7 TCHEN 0 WALK— CLOS SAFE PA BELOW LAUI\ DRY, U7 1. . _____ K9 FURNISH 8c CONNECTIONS TO DW WITH STOP LIVING/D VALVE NG NOTE: SEL DVVGpP4.1 RISER DIAGRAM FOR' PIPE SIZES B9 I 4"SS U3 rE NING MASTER BEDROOV NING WALK- 4"SS BEDROOM K9 KITCHEN PL TvP "WASTE 4c/A"11-1 DW WITH STOP VALVE VB TCI-71N) M2 \G PAR FURNISH 8c INSTALL CONNECTIONS TO DW WITH STOP VALVE 4"KS TO ICE MAKER WITH STOP VALVE I Li 3"LS 2"LV SF MASTER BEDROOM M9 BR M3 AL NG CLOS 173711 ecc A\S CLOS \ WALK—IN CLOS I 4"SS 2"LV LIVING /D NG BATH )/27\ p-3-3---`°°3 BATH A\S vp o rmlo SF 5"COND I B5.2 I BEDROOM M5 V V U2 — CONNECTIONS TO DW WITH STOP VALVE P-7 VB 0 SAFE P I BELOW PAR A C 41110 BAT CLOS MASTER BEDROO M9 Fl BR M3 NG A TYP. V ASTER M9 FURNISH & INSTALL CONNECTIONS T DW WITH STOP VALVE SF SF CLOS M8 CEM BEDROOM M5 SF SF M4 EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc r,m, ALL RIGHTS RESERVED IL UD ArchitectureSite Planning Project Management PROGRESS SET 00 SCALE: 0 SALEM, MASSACHUSETTS 01970 CD MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: DRAWING #: 246 Walnut Street co co -41 co co 0 P2.3 617 . 581 . 6611 fax 617 . 581 . 6601 E5 ©TISE DESIGN ASSOCIATES, INC 2019 BEDROOM U5 K6 4"KS 3"V • P-5 KITCHEN M2 WLK CLOS 1IL6.1 11 Y2"IW II 13"LS 12 LV II II p,BR LIVING/DIN NG II I II M3 PL,VB \C II II II II II II II II II J 000 1 B6.11 4"SS 3"V T PLA 9 B SCAL M ASTER BEDROOM U9 SCAL JU4I \S T"P B BEDROOM M5 Y2"CW DROP Y2"HW DRO LAUD CLOS B P M6 1 HW CW GAS B WALK—IN WAL—FIN CR0 CLOD CLOS BEDROOM M5 1 B M7 1 / HW CW E I VP1J C BATH L7+ 1 Y2"IW 3 2"LV F A TY v ASTER BEDROOM II El L 1 0" -F- A A TV. WALK CLOS I \BR LIVING/DIN NG M3 /8 \C J\ 1' 0" T P 0 7 U6 A\B C 0 "P P P„ SCAL B \C BI L6 1 Y2„IWI \ 3"LS G 2"LV C BED M5 BOO I KA�h T2 / \ / V B BED M5 \ T P LA \ B T"P CLOS ROOM B / / / / P 7 7 V N V \ BATH CW DROP "HW DROP P-1 MASTER BATH M6 fV ASTER BEDROOM U9 P-4 A TN D J CORR T01 DOR 1 B7.11 4"SS 3"V II— \ / HW \ / \ 2"W&T CW GAS 1 K7 I\ / 4"KS \ / 3"V /\ / \ / \ / \ 1 87.1 4"SS 3"V CLOS K LAUNDRY M7 P-6 TC M2 P-5 STUDY P-4 EN BEDROOM U5 B SF Ir F CLOS SF X BEDROOv U5 li CO 0 0 11 LAUNDRY U7 A YP. P SCA J B VB \C E. 1 /L" - 1 ' LOW WALL N \BR A -ORDABL LIVING/DIN U3 RD NG B 1"G DR EN U21 _-71 E C \L D TC L J JBR A ORDAB LIVING/DIN NG U3 CAL BED U5 HW CW GAS CLOS a 2"W&T CLOS 4"KS HW CW GAS CLOS BEDROOM U5 4"SS CLOS M8 SF SF AT 4"SS WALK—IN CLOE STUDY M SF SF STUDY ASTE BEDROOM ASTE BEDROOM M9 A2 1 Y2"IW 2"LVM A TYP. c) ft BA [HI M4 i, a C >.< LAUND M7 u' CLOS 68.11 SF BEDROOM M5 0-1 cLoz 4"KS TC EN M2 LH- LOW WALL NG SF BEDROOM / 4"KS 1"G DROP KITCHEN M2 SF EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ALL RIGHTS RESERVED Project #: 4017 CD PROGRESS SET CO SCALE: 0 SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. DRAWING TITLE: REGISTRATION: DRAWING #: P) 246 Walnut Street co 0 CO CO CO CO ©TISE DESIGN ASSOCIATES, INC 2019 S1 Q I L6 I / 1 Y2"IW 3"LS < 2"LV oc�• 9N \2R II ELEV ELEVATOR LOBBY 106 I L6.1 I 1 Y2"IW LS 2"LV MECH CLOS Q R o Q VESTIB,LE 101 Q C 11 C RDJ ✓8 \C SCALE: 1 /L" 1 C D M7 HW CW GAS GAS FIREPLACE P \C SCALE: 1/L" - 0" J HALL 104 I L7 1 Y2"IW\ 3"L 2L D R ROO 211 B7.1I 4"SS 3"V MUN M I L13 I 1 Y2"w 3"LS 2"LV A\S TY CORRIDOR ARC T01 -D D A\ LI D 00 J l� MAIL BOX SAIL ROOVV 103 R J N LOBBY 102 F \ � yy �\ (� RD 0 0 0 DOOR CO -CO\D H • C N N 0 0 0 I L8 1 Y2"IW 3"LS I L7.1 I 2"LV 1 Y2"IW 3"LS 2"LV \/ V O \ A I 137.21 4"SS OCR COS, AR N A & I/ I K11 I 4"KS 3"V VO\ AR F TNESS 212 I M7 I HW CW GAS -A TA hi 1, i1 L SPAC D 000 I L12 I 1 Y2"Iw 3"LS 2"LV -TAIL 107 D SF SF V V I0 M7 II WALK- N 1I 4"SS 3V TYP, MASTER BAT Ub M10 I HW CW GAS I M8 HW CW GAS • • \ I M11 %4"HW 1 Y2"CW 1 Y2"GAS 1.43tr_1011, C B8 4"SS 3"V 4 c- I I I11 I I I I I I I STIAI - 4 -k I- I L 000 / I \ / \ 1 I -11. I L J I L9 I 1 Y2"IW 3"LS 2"LV E EDE, INC. MEP/FP ENGINEERS 1185 Washington St. Suite 4 West Newton, Ma. 02465 Tel. (617)-969-7700 Fax. (617)-969-7709 E-Mail. ede@edemep.com COPYRIGHT 2015-EDE Inc ©ALL RIGHTS RESERVED Project #: 4017 121 JL w 0 0 CC 0 W ArchitectureSite Planning Project Management PROGRESS SET 00 N 0 J_ SCALE: PROJ ECT#: SALEM, MASSACHUSETTS 01970 MAR 22,2019 BUILDING PERMIT SET URBAN SPACES L.L.C. & DIAMOND & SINACORI L.L.C. O a) DRAWING TITLE: REGISTRATION: DRAWING #: P) 246 Walnut Street CD CCO LO U ti L 0 CO CD co 2 a) C 0 Q) z 617 . 581 . 6601 ©TISE DESIGN ASSOCIATES, INC 2019