2 South Ridge Circle - Permit SetCONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:19:48 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTDrawing ListG-001PERMIT-CD3/03/20203/03/20202018.19112DRAWING LISTSheet PageNumberSheetNumberSheet Name1 G-001 Drawing List2 G-002 Abbreviations, Annotations & Components3 G-003 Specifications4 A-101 Basement / Foundation Plan5 A-102 First Floor Plan6 A-103 Second Floor Plan7 A-104 Roof & Area Plans8 A-201 Building Elevations9 A-202 Building Elevations10 A-301 Building Sections11 A-302 Wall Sections & Details12 A-601 SchedulesPROPOSED HOUSE2 SOUTH RIDGE CIRCLE, SALEM MA 01970NOTE: SEE OTHERS FOR CIVIL AND BLDG STRUCTURAL DWGS; ENERGY ANALYSISREVISION SCHEDULENo. Date Description
FDSCHSCOABAnchor BoltABVAboveACTAcoustic Ceiling TileAFFAbove Finish FloorALTAlternateALTRNAlterationBBBaseboardBELBelowBFEBase Flood ElevationBLDGBuildingBLKBlockBLKGBlockingBOFBottom of FootingBRDBoardBSMTBasementBTWBetweenC-C SFIClosed-cell Spray Foam Insul.CHDPECorragated High Density PECJContruction JointCLJControl JointCLCenter LineCLLColumn LineCLOClosetCLRClearCMUConcrete Masonry UnitCNTRCounterCRNCornerCOConcrete Opening / Code OfficialCOLColumnCONCConcreteCONNConnectionCONTContinuousCSGCasingCTCeramic Tile / CountertopDECDecorativeDIADiameterDIFDetermine in fieldDIMDimensionDJDouble JoistDLDead LoadDNDownDODittoDPDampproofingDRDining RoomDRDoorDRDouble RabbetDSDownspoutDWDishwasherDWGDrawingEAEachELElevationELECElectricalELEVElevatorENGEngineer / EngineeringEPSExpanded PolystyreneEQEqualEXGExistingEXG GRExisting GradeEXTExteriorEXP BTExpansion BoltEXP JTExpansion JointFE Fire ExtingisherFECFire Extingisher CabinetFDFloor DrainFDNFoundationFFLFinish Floor LineFGLFiberglassFLFlashingFOCFace of ConcreteFOFFace of FinishFOMFace of MasonryFOSFace of StudFRFramingFRTWFire-retartant Treated WoodFTGFootingGARGarageGLGlassGRGroutGWBGypsum Wall BoardHHighHBHose BibbHCHandicapHCHollow CoreHCPHandicappedHDRHeaderHGRHangerHMHollow MetalHORIZHorizontalHRDWHardwoodHTHeightIBCInternational Building CodeINSLU InsulationINTRInteriorIRCInternational Residential CodeOAOverallOCOn CenterO-C SFIOpen-cell Spray Foam Insul.O/C-C SFICombo. Open and Closed-Cell SFIODOutside DiameterOPGOpeningOPTOptionalOSOffsetPEPolyethylenePLPlatePNTPaintPTPressure TreatedPTDPaintedPTNPartitionPWDPlywoodQUALQualityQTYQuanityQTQuarry TileRStair RiserRCPReflected Ceiling PlanREFRRefrigeratorRETRetainingRMRoomRORough OpeningRVRidge VentSCRNScreenSDLSaddleSHTHSheathingSIMSimilarSLRSealerSLTSealantSMSheat MetalSMSmoothSPECSpecificationSPKLRSprinklerSRSingle RabbetSSStainless SteelSTLSteelSTRUCTStructuralTStair TreadTBDTo Be DeterminedT>ongue & GrooveTHKThickTMXTo Match ExistingTOFTop of FootingTOSTop of SlabTOCTop of ConcreteTYPTypicalUONUnless Otherwise NotedUNEXUnexcavatedVBVapor Barrier, Vapor BaseVCTVinyl Composition TileVERTVerticalVIFVerify in FieldVLVerify LocationVRVapor RetarderVWAVerify With ArchitectVWEVerify With EngineerVWOVerify With OwnerW/WithWDWidthWDWoodWPWater ProofingWWFWelded Wire FabricXPSExtruded PolystyreneJSTJoistJTJointKDKiln DriedKITKitchenLLineLINLinen ClosetLLLive LoadLLLease LineLRLiving RoomLTGLightingLVRLeverMAXMaximumMBRMaster BedroomMCMedicine CabinetMETMetalMINMinimumMLMetal LathMLDGMoldingMOMasonry OpeningMRMoisture ResistantMWOMicrowave OvenNATNaturalNICNot In ContractNO, #NumberNTSNot To ScaleRoom name101Room name101150 SF1A101SIM1A101SIM1View Name1/8" = 1'-0"1t1010'2'4'8'16'A1011SIM0NameElevationLEVEL MARKERROOM TAGDOOR TAGWINDOW TAGSECTION MARKERGRAPHIC SCALEKEYNOTE TAGREVISION TAGPROJECT NORTHDETAIL VIEWMARKERTRUE NORTH?/1A101VIEWREFERENCEROOM TAGW/ AREAREVISIONCLOUDSTRUCTURAL GRIDMARKERDETAIL MARKERSPOT ELEVATIONVIEW TITLE / SCALECENTERLINEEXISTINGPARTITIONNEW PARTITIONSDEMOLITIONPARTITIONCOMBINATIONSMOKE / CODETECTORSMOKEDETECTORBLANKET OR SPRAYFOAM INSULATION ASNOTEDSTRUCTURALFRAMINGSECTION -CONTINUOUSWOODBLOCKINGCONCRETE WALLEXTERIOR 2X6 STUD WALLINTERIOR 2X4 STUD WALLINTERIOR 2X6 STUD WALLEXTERIOR BRICK VENEERW/ 2X6 STUD WALLFLOOR DRAINCO DETECTORCMU WALLHEAT DETECTORCEILING BATHEXHAUSTS/CSCOHCONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:19:50 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTAbbreviations,Annotations &ComponentsG-002PERMIT-CD3/03/20203/03/20202018.19212 1/4" = 1'-0"Abbreviations 1/4" = 1'-0"Annotations 1/4" = 1'-0"ComponentsREVISION SCHEDULENo. Date Description
CONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:19:52 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTSpecificationsG-003PERMIT-CD3/03/20203/03/20202018.19312DIVISION 1 - GENERAL REQUIREMENTSSECTION 01000 - PROJECT REQUIREMENTS (CONTRACTOR IMPLIED UON)PROJECT REQUIREMENTS:1.SITE CONDITIONS AND RESTRICTIONS: SEE OWNER.2.USE OF PREMISES AND ADJACENT FACILITIES: SEE OWNER.INSURANCE:1. CONTRACTOR SHALL CARRY INSURANCE COVERAGE NECESSARY FOR THE COMPLETIONOF PROJECT. PROVIDE WORKMEN'S COMPENSATION, LIABILITY INSURANCE, PROPERTYDAMAGE, AND OTHER INSURANCE REQUIRED BY LAW.2. OWNER SHALL CARRY FIRE AND VANDALISM INSURANCE.TAXES:1. COST FOR TAXES, SALES TAX, AND OTHER CHARGES RELATIVE TO CONSTRUCTIONOF THE PROJECT SHALL BE INCLUDED IN THE CONTRACT SUM.PERMITS:1. APPLY FOR, OBTAIN, AND PAY FOR BUILDING PERMITS, OTHER PERMITS, ANDUTILITY COMPANY BACK CHARGES REQUIRED TO PERFORM THE WORK.INTENT:1. DRAWINGS AND SPECIFICATIONS ARE INTENDED TO PROVIDE THE BASIS FORTHE PROPER COMPLETION OF THE PROJECT SUITABLE FOR THE INTENDED USE OFTHE OWNER.2. ITEMS NOT EXPRESSLY SET FORTH BUT WHICH ARE REASONABLY IMPLIED ORNECESSARY FOR THE PROPER PERFORMANCE OF THIS WORK SHALL BE INCLUDED.COORDINATION:1. COORDINATE THE WORK OF ALL TRADES.2. PREPARE COORDINATION DRAWINGS FOR AREAS ABOVE CEILINGS WHERECLOSE TOLERANCES ARE REQUIRED BETWEEN BUILDING ELEMENTS ANDMECHANICAL, PLUMBING, AND ELECTRICAL WORK.3. VERIFY LOCATION OF UTILITIES AND EXISTING CONDITIONS. NOTIFY ARCHITECT OFCONDITIONS DIFFERING FROM THOSE INDICATED ON THE DRAWINGS.4. VERIFY DIMENSIONS ON DRAWINGS WITH DIMENSIONS AT THE PROJECT. DO NOTSCALE DRAWINGS.CUTTING AND PATCHING:1. PROVIDE CUTTING AND PATCHING WORK TO PROPERLY COMPLETE THE PROJECT.2. DO NOT REMOVE OR ALTER STRUCTURAL COMPONENTS WITHOUT WRITTEN APPROVAL.3. CUT WITH TOOLS APPROPRIATE FOR MATERIALS TO BE CUT.4. PATCH WITH MATERIALS AND METHODS TO PRODUCE PATCH WHICH IS NOT VISIBLEFROM A DISTANCE OF FIVE FEET.5.DO NOT CUT AND PATCH IN A MANNER THAT WOULD RESULT IN A FAILURE OF THEWORK TO PERFORM AS INTENDED, DECREASE FIRE PERFORMANCE, DECREASEACOUSTICAL PERFORMANCE, DECREASE ENERGY PERFORMANCE, DECREASE OPERATIONALLIFE, OR DECREASE SAFETY FACTORS.FIELD ENGINEERING:1. VERIFY AND LOCATE UTILITIES, EXISTING FACILITIES, AND EQUIPMENT.2. SURVEY AND LAYOUT IMPROVEMENTS, UTILITIES, STRUCTURES, AND COMPONENTS.PROJECT MEETINGS:1. ARRANGE FOR A PRECONSTRUCTION CONFERENCE PRIOR TO START OF CONSTRUCTION.MEETING SHALL BE ATTENDED BY OWNER, ARCHITECT, CONTRACTOR, ANDMAJOR SUBCONTRACTORS.2. ARRANGE FOR PROGRESS MEETINGS ONCE A MONTH DURING CONSTRUCTION. RECORDMINUTES AND DISTRIBUTE PROMPTLY.QUALITY ASSURANCE:1. COMPLY WITH APPLICABLE CODES, REGULATIONS, ORDINANCES AND REQUIREMENTS OFAUTHORITY HAVING JURISDICTION, INCLUDING ACCESSIBILITY GUIDELINES WHERE APPLICABLE. SUBMITCOPIES OF INSPECTION REPORTS, NOTICES AND SIMILAR DOCUMENTS TO ARCHITECT.2. PROVIDE PRODUCTS OF ACCEPTABLE MANUFACTURERS WHICH HAVE BEEN INSATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS.3. USE EXPERIENCED INSTALLERS. FURNISH EVIDENCE OF EXPERIENCE IF REQUESTED.4. DELIVER, HANDLE, AND STORE MATERIALS IN STRICT ACCORDANCE WITHMANUFACTURER'S INSTRUCTIONS.5.USE OF ANY SUPPLIER OR SUBCONTRACTOR IS SUBJECT TO OWNER'S APPROVAL.6. ENGAGE AND PAY FOR TESTING AGENCIES AS REQUIRED. REFER TO INDIVIDUAL SECTIONSFOR ADDITIONAL REQUIREMENTS.TEMPORARY FACILITIES:1. PROVIDE TEMPORARY FACILITIES AND CONNECTIONS AS REQUIRED FOR THE PROPERCOMPLETION OF THE PROJECT.2.PROVIDE AND MAINTAIN TEMPORARY UTILITY SERVICES.3.[METER AND PAY FOR UTILITY SERVICE.] [OWNER WILL PAY FOR UTILITY SERVICE CONSUMED.]DO NOT WASTE. DETERMINE OPTION WITH OWNER.4. PROVIDE TEMPORARY PROTECTION FOR ADJACENT AREAS TO PREVENT CONTAMINATIONBY CONSTRUCTION DUST AND DEBRIS.5. PROVIDE TEMPORARY BARRICADES AS NECESSARY TO ENSURE PROTECTION OF THE PUBLIC.6. MAINTAIN EGRESS WITHIN AND AROUND CONSTRUCTION AREAS.7. MAINTAIN FIRE ALARM SYSTEMS IN OPERATION DURING CONSTRUCTION.8. PROVIDE FIRE EXTINGUISHERS IN WORK AREAS DURING CONSTRUCTION.9. PROVIDE TEMPORARY PROTECTION FOR ADJACENT CONSTRUCTION. PROMPTLYREPAIR ANY DAMAGE AT NO ADDITIONAL COST TO OWNER.PRODUCTS AND SUBSTITUTIONS:1. PROVIDE PRODUCTS AND MATERIALS SPECIFIED. REQUEST OWNER'S AND ARCHITECT'SELECTION OF COLORS AND ACCESSORIES IN SUFFICIENT TIME TO AVOID DELAYING PROGRESS OF THEWORK.2. SUBMIT REQUESTS FOR SUBSTITUTIONS SHALL BE IN WRITING, INCLUDING REASONS. SUBMITSUFFICIENT INFORMATION FOR ARCHITECT TO EVALUATE PROPOSED SUBSTITUTION.3. REMOVE AND REPLACE WORK WHICH DOES NOT CONFORM TO THE CONTRACT DOCUMENTSAT NO ADDITIONAL EXPENSE TO THE OWNER.INSTALLATIONS:1. INSPECT SUBSTRATES AND REPORT UNSATISFACTORY CONDITIONS IN WRITING.2. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.3. TAKE FIELD MEASUREMENTS PRIOR TO FABRICATION WHERE PRACTICAL. FORMTO REQUIRED SHAPES AND SIZES WITH TRUE EDGES, LINES AND ANGLES. PROVIDEINSERTS AND TEMPLATES AS NEEDED FOR WORK OF OTHER TRADES.4. INSTALL MATERIALS IN EXACT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONSAND APPROVED SUBMITTALS.5. INSTALL MATERIALS IN PROPER RELATION WITH ADJACENT CONSTRUCTION ANDWITH PROPER APPEARANCE.6. RESTORE UNITS DAMAGED DURING CONSTRUCTION INSTALLATION. REPLACE UNITS WHICHCANNOT BE RESTORED AT NO ADDITIONAL EXPENSE TO OWNER.CLOSEOUT:1. PREPARE PUNCH LIST FOR REMAINING WORK FOR REVIEW BY ARCHITECT.2. COMPLETE PUNCH LIST ITEMS PROMPTLY AT NO ADDITIONAL EXPENSE TO THE OWNER.3. SUBMIT ACCURATE RECORD DOCUMENTS OF CONSTRUCTION.4. SUBMIT OPERATING MANUALS, MAINTENANCE MANUALS, AND WARRANTY INFORMATION.5. OBTAIN AND SUBMIT COPY OF OCCUPANCY PERMITS.6. TRAIN OWNER OF IN USE OF BUILDING SYSTEMS.7. REMOVE TEMPORARY FACILITIES AND PROVIDE FINAL CLEANING AND TOUCH-UP.8. RESTORE PORTIONS OF BUILDING, SITE IMPROVEMENTS, LANDSCAPING AND OTHER ITEMSDAMAGED BY CONSTRUCTION OPERATIONS TO THE SATISFACTION OF THE OWNER AT NO ADDITIONALEXPENSE TO OWNER.ALLOWANCES:1.SEE OWNER FOR FOLLOWING.A.LIGHTING FIXTURE ALLOWANCEB.DOOR HARDWARE ALLOWANCEC.CERAMIC TILE ALLOWANCED.FLOORING ALLOWANCEDIVISION 6 - WOOD AND PLASTICSECTION 06401 - EXTERIOR ARCHITECTURAL WOODWORK:SUMMARY:1.PROVIDE EXTERIOR ARCHITECTURAL WOODWORK:A.STANDING AND RUNNING TRIM AND RAILS.B.ORNAMENTAL ITEMS.PRODUCTS:1.AWI STANDARDS: ARCHITECTURAL WOODWORK INSTITUTE (AWI) "ARCHITECTURALWOODWORK QUALITY STANDARDS".2.WIC STANDARDS: WOODWORK INSTITUTE OF CALIFORNIA (WIC) "MANUEL OF MILLWORK"3.PLASTIC TRIM : STANDARD PER AZEK OR VERSATEX TRIMBOARD4. PRESERVATIVE TREATMENT: COMPLY WITH CODES AND REGULATIONS.5.(((EXTERIOR STANDING AND RUNNING TRIM AND RAILS:)))A.AS SELECTED BY OWNERB.TEXTURE: SMOOTH.C.FINISH: UNPAINTED (WHITE) STAIN/PAINT TRIM WHITE - VWO.6.AUXILIARY MATERIALS:A.NAILS: STAINLESS STEEL THIN SHANK, BLUNT POINT, FULL ROUND HEAD.B.SCREWS AND ANCHORS: NONCORROSIVE, TYPE REQUIRED FOR SECUREINSTALLATION:1.COMPLY WITH REQUIREMENTS OF SECTION O1000 - PROJECT REQUIREMENTS.2.COMPLY WITH STANDARDS REFERENCED AS APPLICABLE.3. AS APPLICABLE BACKPRIME WORK BEFORE INSTALLATION.4.PROVIDE TRIM FOR SCRIBING AND SITE CUTTING.5.INSTALL WORK PLUMB, LEVEL AND IN PROPER ALIGNMENT.6.PROVIDE WORK FREE FROM TOOL MARKS AND BLEMISHES.7.SECURELY FASTEN TO SUBSTRATES.8.INSTALL IN LENGTHS TO MINIMIZE JOINTS AND SEAMS.9.COLOR MATCH WOOD / PLASTIC AT JOINTS FOR UNIFORM APPEARANCE10.TOUCH-UP DAMAGED OR ABRADED FINISHES.DIVISION 7 - THERMAL AND MOISTURE PROTECTIONSECTION 07210 - BUILDING INSULATIONSUMMARY:1.PROVIDE BUILDING INSULATION AND VAPOR RETARDERS.A.UNDER SLAB-ON-GRADE, BOARD TYPE.B.THERMAL INSULATION IN EXTERIOR WALLS, BOARD TYPE AT WINDOW ANDDOOR HEADERS. WALLS IN BFE, AS APPLICABLE.C.1. THERMAL INSULATION IN STUD FRAMED EXTERIOR WALLS, CC SPRAY FOAM2. THERMAL INSUL. BASEMENT CONC. WALLS (INT. FACE) DOW THERMAX WHITED.THERMAL INSULATION AT FLOOR / UNDERSIDE OF ROOFS, OVER HEATED SPACES,CC, OC, HYBRID SPRAY FOAM OR BLANKET TYPE PER DRAWINGS.E.N/AE.ACOUSTIC INSULATION AT INTERIOR PARTITIONS, BLANKET TYPE.F.AIR SEALING LOW EXPANSION FOAM.G.AIR SEALING HIGH EXPANSION FOAM.H.SHEET VAPOR BARRIER AS SPECIFIED PER HERS CONSULTANT.PRODUCTS:1.BOARD INSULATION:A.EXTRUDED POLYSTYRENE (XPS), RIGID, ASTM C 578.B.VAPOR RETARDER: INTEGRAL VAPOR RETARDER AS REQUIRED FOR APPLICATION.C.PRODUCT: GREENGUARD COMMERCIAL PRODUCTS, CM INSULATION BOARD.2.BLANKET/BATT INSULATION:A. GLASS FIBER, ASTM C 665, TYPE II, CLASS C, CATEGORY 1 (UNFACED), WATERVAPOR PERMEANCE, ASTM E 96, GREATER THAN 1.0 PERMS, ODOR EMISSIONSASTM C 1304.B.PRODUCT: JOHNS MANVILLE FORMALDEHYDE-FREE FIBER GLASS INSULATION, UN-FACED BATTS.3.VAPOR RETARDER (NOT INTEGRAL WITH INSULATION):A.POLYETHYLENE, ASTM D 4397, 10 MIL MIN. OR WHITE CROSS-LAMINATED VIRGINPOLY SHEETING, ABOVE RIGID INSULATION UNDER SLAB. VR OPTIONAL IF INSTALLING XPSBOARD INSULATION.B.PRODUCT: PER HERS CONSULTANT4.ACCESSORIES:A.CRACK SEALERS AND TAPES.B.LOW AND HIGH EXPANSION JOINT FILLERS.INSTALLATION:1.COMPLY WITH REQUIREMENTS OF SECTION 01000 - PROJECT REQUIREMENTS.2.INSTALL INSULATION AND VAPOR RETARDERS WITH CONTINUOUS COVERAGE TOPROVIDE OPTIMUM PERFORMANCE IN ACCORDANCE WITH ENERGY AND ENVIRONMENTALBUILDING ASSOCIATION'S (EEBA) "BUILDING GUIDE TO COLD CLIMATE".3.ALLOW TWO-INCH AIR SPACE MIN. BETWEEN ROOF SHEATHING AND INSULATION.SECTION 07310 ROOF SHINGLES AND WALL SIDINGSUMMARY:1.PROVIDE ASPALT SHINGLES FOR ROOFING APPLICATIONS.2.PROVIDE VINYL CLAPBOARDS FOR SIDING APPLICATIONS.SUBMITTALS:1.SUBMIT PRODUCT DATA, SAMPLES, 40 YEAR WARRANTY.PRODUCTS:1.PRODUCTS: CERTAINTEED SHINGLES, WINTERGUARD, ROOFER'S SELECT VWO.2.SHINGLES:A.SQUARE TAB, FIBERGLASS BASED ASPHALT SHINGLES. STYLE, WEIGHT ANDCOLOR PER OWNER, VERIFY W/ ARCHITECTB.ACCESSORIES: HIP AND RIDGE SHINGLES AS APPLICABLE; FELT, ASTM D 226;RUBBERIZED ASPHALT PERIMETER UNDERLAYMENT; METAL FLASHING AND DRIP EDGE.3.VINYL SHINGLES: N/A4.VINYL CLAPBOARDS:A.HARVEY OR EQUAL PER OWNERB.COLOR: TBD5.FASTENERS AND ACCESSORIES: AS REQUIRED BY MANUF.INSTALLATION:1.COMPLY WITH REQUIREMENTS OF SECTION 01000 - PROJECT REQUIREMENTS.2.COMPLY WITH NRCA STEEP ROOFING MANUAL.3.COORDINATE SHINGLE INSTALLATION WITH FLASHING AND METAL ACCESSORIES TOSHED WATER PROPERLY.DIVISION 16 ELECTRICALSECTION 16000 ELECTRICALSUMMARY:1.PROVIDE ELECTRICAL SYSTEMS FOR THE FOLLOWING:A.LIGHTING; INTERIOR & EXTERIORB.POWERC.AUXILLARY SYSTEMS PER LOCAL & STATE CODE. OPTIONAL SYSTEMS PER OWNER.2.MODIFY, RELOCATE AND EXTEND EXISTING SERVICE TO ACCOMMODATE NEWWORK AS APPLICABLE.3.MAINTAIN FIRE ALARM SYSTEM IN OPERATION DURING CONSTRUCTION.4.COORDINATE WITH OWNER'S ROOM USES TO PROVIDE ADEQUATE SYSTEM FORALL CONTRACT AREAS.NEW SERVICE:1. UPGRADE EXISTING AMP ELECTRIC SERVICE, VOLTAGE AND PHASE ASAPPLICABLE.PRODUCTS:1.PROVIDE NEW MATERIALS SUITABLE FOR SERVICE INTENDED COMPLYING WITHAPPROVED SUBMITTALS. PROVIDE ACCESSORIES SUCH AS CONTROLS, COVER PLATES,AND CONNECTIONS TO EQUIPMENT. FINISH AS SELECTED BY OWNER.INSTALLATION:1.COMPLY WITH REQUIREMENTS OF SECTION 01000 – PROJECT REQUIREMENTS.2.COMPLY WITH APPLICABLE CODES, REGULATIONS, ORDINANCES ANDREQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND NATIONAL ELECTRICALCODE.3.PROVIDE CORE DRILLING AS REQUIRED FOR NEW WORK.4.CONCEAL CONDUIT TO THE GREATEST EXTENT PRACTICAL.5.INSTALL LIGHT SWITCHES AT UNIFORM HEIGHT ABOVE FINISHED FLOOR. LOCATESWITCHES WITHIN ROOMS AT STRIKE SIDE OF DOOR UNLESS NOTED OTHERWISE.6.GANG MOUNT MULTIPLE SWITCHING LOCATIONS. MOUNT MULTIPLE TYPES OFCONTROLS AS CLOSE TOGETHER AS POSSIBLE AND IN LINE WITH EACH OTHER ATUNIFORM HEIGHT ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE.7.GROUP MULTIPLE JUNCTION BOXES, TELEPHONE AND ELECTRICAL OUTLETSTOGETHER ON WALLS. AVOID BACK TO BACK BOX LOCATIONS.8.MOUNT ELECTRICAL, DATA, AND TELEPHONE OUTLETS VERTICALLY, AT UNIFORMHEIGHT ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE.9.MAINTAIN INDICATED FIRE RATINGS OF WALLS, PARTITIONS, CEILINGS, ANDFLOORS AT PENETRATIONS. SEAL WITH FIRESTOPPING TO MAINTAIN FIRE RATING.10.TEST ALL SYSTEMS FOR PROPER OPERATION.11.LABEL CIRCUITS IN ELECTRICAL PANELS.12.INSTRUCT OWNER'S PERSONNEL IN PROPER OPERATION OF SYSTEMS.FIXTURE SCHEDULE:1.AS SELECTED BY OWNER AND LIGHTING CONSULTANT. SECTION 09255 - GYPSUM BOARD ASSEMBLIESSUMMARY:1.PROVIDE GYPSUM BOARD ASSEMBLIESA.HOUSEB.GARAGEPRODUCTS:1.GEORGIA-PACIFIC OR APPROVED EQUAL AS APPLICABLE2.SIZE: 1/2"3.SIZE: 5/8" TYPE X .INSTALLATION:1.COMPLY WITH REQUIREMENTS OF SECTION 01000 - PROJECT REQUIREMENTS.2.INSTALL JOINTS ONLY OVER FRAMING MEMBERS. DO NOT ALLOW BUTT-TO-BUTT JOINTS.3.PROVIDE ACOUSTICAL SEALANT AT RUNNER TRACKS, WALL PERIMETERS, OPENINGS,EXPANSION,AND CONTROL JOINTS.4.INSTALL GYPSUM BOARD ASSEMBLIES TRUE, PLUMB, LEVEL AND IN PROPER RELATION TOADJACENT SURFACES.5.WHERE NEW PARTITIONS MEET EXISTING CONSTRUCTION, REMOVE EXISTINGCORNERBEADS TO PROVIDE SMOOTH TRANSITION6.PROVIDE 3-COAT JOINT TREATMENT SUCH THAT, AFTER FINISHING, JOINTS ARE NOT VISIBLE.7.SAND AND LEAVE READY FOR FINISH PAINTING AND WALL TREATMENT AS APPLICABLE.SECTION 09900 - PAINTINGSUMMARY:1.PROVIDE PAINTING AND SURFACES PREPARATION FOR INTERIOR AND EXTERIORUNFINISHED SURFACES.2.PROVIDE REPAINTING AND SURFACE PREPARATION AT AREAS OF REMODELING ASAPPLICABLE.3.PROVIDE PAINTING OF ENTIRE SURFACE WHERE PATCH PAINTING IS REQUIRED ASAPPLICABLE.SUBMITTALS:1.SUBMIT PRODUCT DATA, SAMPLES, 4 FOOT BY 4 FOOT MOCKUP OF EACH COLOR,EXTRA STOCK CONSISTING OF ONE UNOPENED GALLON OF EACH TYPE OF PAINT USED.PRODUCTS:1.AS SELECTED BY OWNER.INSTALLATION:1.COMPLY WITH REQUIREMENTS OF SECTION 01000 - PROJECT REQUIREMENTS.2.PROVIDE FIELD-APPLIED MOCK-UPS OF EACH COLOR AND FINISH SELECTED ONACTUAL SURFACES TO BE PAINTED.3.TEST SAMPLE FOR ADHESION FOR EACH TYPE OF PAINT.4.REMOVE COVER PLATES AND PROTECT HARDWARE AND ADJACENT SURFACES.5.SAND BEFORE PAINTING UNTIL SMOOTH AND FLAT AND SAND BETWEEN COATS.6.APPLY PAINT TO ACHIEVE MANUFACTURER'S RECOMMENDED DRY FILMTHICKNESSES.7.PAINT ENTIRE SURFACE WHERE PATCH PAINTING IS REQUIRED.8.RECOAT AREAS WHICH SHOW BLEED-THROUGH OR DEFECTS.9.CLEAN PAINT SPATTER FROM ADJACENT SURFACES AND GLASS.10.TOUCH-UP DAMAGES SURFACES AT COMPLETION OF CONSTRUCTION.SECTION 08610 - VINYL WINDOWSSUMMARY:1.PROVIDE VINYL WINDOWSPRODUCTS:1.PRODUCTS: HARVEY WINDOWS (CLASSIC OR SLIMLINE (TBD))2.VINYL WINDOWS:A.WINDOW TYPE: VINYL EXTRUDED WINDOWSB.WINDOW OPERATION: DOUBLE HUNG. WINDOW OPENING LIMITING DEVICEAS REQ. PER IRC / 780 CMR STANDARD.C.WINDOW GRADE: DP RATING AS REQUIREDD.GLAZING: LOW-E, ARGON-FILLED INSULATION GLASS.E.GLAZING PATTERN: SINGLE PANE PER SASH WITH APPLIED GRILLESPER BLDG. ELEVATION PATTERN (TBD). VERIFY WITH OWNER.F.INTERIOR WOOD FINISH: N/A3.AUXILIARY MATERIALS: HURRICANE ANCHORS AS REQUIRED, OPERATING HARDWARE,INSECT SCREENING, FLASHING PER MANUF./ MANUF. RECOMMENDATIONS.INSTALLATION:1.COMPLY WITH REQUIREMENTS OF SECTION 01000 - PROJECT REQUIREMENTS.DIVISION 8 - DOORS AND WINDOWSSECTION 08212 - STILE AND RAIL WOOD DOORSSUMMARY1.PROVIDE STILE AND WOOD RAIL DOORS:A.EXTERIOR STILE AND RAIL DOORS.B.INTERIOR STILE AND RAIL DOORS.SUBMITTALS:1.SUBMIT PRODUCT DATA, SAMPLES, SHOP DRAWINGS, WARRANTY.PRODUCTS:1.PRODUCTS:THERMA-TRU . EXTERIOR ENTRANCE & GARAGE OVERHEAD DOORS.JELD-WEN MORGAN SERIES. INTERIOR. SEE DOOR SCHEDULE / STYLE PER OWNER2.NWWDA QUALITY STANDARDS FOR STILE AND RAIL DOORS: NWWDA I.S.6.3.EXTERIOR STOCK STILE AN RAIL DOORS:A.QUALITY STANDARD: NWWDA I.S.6.B.PANEL CONFIGURATION: SEE ELEVATIONS.C.GLAZING: INSULATING GLASS. N/A.D.GLAZING COLOR: CLEAR GLASS. N/A.E.CLAD: COLOR. SEE DOOR SCHEDULE OR OWNER.4.INTERIOR STOCK STILE AND RAIL DOORS:A.QUALITY STANDARD: NWWDA I.S.6.B.DESIGN GROUP: INTERIOR PANEL TYPE, 1-3/8 INCH THICK.C.PANEL CONFIGURATION: PER OWNERD.FINISH: PER OWNERE.GLAZING COLOR: CLEAR, TRANSOM W/ MUNTINS, SEE OWNER AS APPLICABLEINSTALLATION:1.COMPLY WITH REQUIREMENTS OF SECTION 01000 - PROJECT REQUIREMENTS.2.COMPLY WITH NWMA IS-1 QUALITY STANDARDS.3.COMPLY WITH NFPA 80 FOR RATED ASSEMBLIESDIVISION 15 HVACSECTION 15500 - HEATING, VENTILATING, AND AIR CONDITIONING.SUMMARY:1.PROVIDE EQUIPMENT, SYSTEMS, AND CONTROLS FOR HEATING IN CONTRACTAREA AS INDICATED OR REQUIRED PER HERS CONSULTANT.2.COORDINATE WITH OWNER'S ROOM USES TO PROVIDE ADEQUATE SYSTEMFOR ALL CONTRACT AREAS.3.COORDINATE LOCATION OF THERMOSTATS AND CONTROLS WITH OWNER'SREQUIREMENTS.4.COORDINATE LOCATION OF DUCTWORK TO AVOID INTERFERENCE WITHLOCATION OF DESIGNATED LIGHTING FIXTURE LOCATIONS (SEE LIGHTINGCONSULTANT'S PLANS).5.DO NOT CUT STRUCTURAL ELEMENTS WITHOUT PRIOR WRITTEN APPROVAL.DESIGN CONDITIONS1.PROVIDE HEATING SYSTEMS FOR USE WITH EXISTING UTILITY SERVICE. ASAPPLICABLE.2.PROVIDE SYSTEMS DESIGNED TO ASHRAE WEATHER DATA USING 97.5PERCENT WINTER DRY BULB AND THE 2.5 PERCENT SUMMER DRY-BULB AND MEANCOINCIDENT WET-BULB CLIMATIC CONDITIONS.3.HEATING LOADS CALCULATED ON ROOM-BY-ROOM BASIS USING ACCA MANUELJ OR OTHER APPROVED METHOD.4.MAINTAIN RELATIVE HUMIDITY ACCORDING TO ASHRAE RECOMMENDATIONS.5.PROVIDE MECHANICAL VENTILATION DESIGNED TO ASHRAE STANDARD 62.2;AND BALANCED ERV (AS APPLICABLE) VENTILATION SYSTEM.PRODUCTS:1.PROVIDE NEW MATERIALS SUITABLE FOR SERVICE INTENDED COMPLYING WITHAPPROVED SHOP DRAWINGS. PROVIDE ACCESSORY ITEMS SUCH AS CONTROLS,ANCHORS AND INSULATION.2.PRODUCT: ERV VENTILATOR AS APPROVED BY OWNER AND HERS RATER:FANTECH OR APPROVED EQUAL.3.PRODUCT: PANASONIC WHISPER QUIET FANS OR FANTECH VENTILATION FANS.RATED FOR CONTINUOUS OPERATION. SEE HERS CONSULTANT'S SPECIFICATIONS.INSTALLATION:1.COMPLY WITH REQUIREMENTS OF SECTION 01000 - PROJECT REQUIREMENTS.2.COMPLY WITH APPLICABLE CODES, REGULATIONS, ORDINANCES ANDREQUIREMENTS OF AUTHORITIES HAVING JURISDICTION, AND WITH SMACNA AND EEBARECOMMENDATIONS.3.CONCEAL PIPING AND DUCTWORK TO THE GREATEST EXTENT PRACTICAL.4.NA5.IF APPLICABLE, AVOID HEATING DUCTS IN OUTSIDE WALLS. IF NECESSARYINSTALL MINIMUM R-14 RIGID INSULATION BETWEEN.6.AS APPLICABLE, CENTER CEILING MOUNTED ELEMENTS IN CENTER OF CEILINGTILES .7.MAINTAIN INDICATED FIRE RATINGS OF WALLS, PARTITIONS, CEILINGS, ANDFLOORS AT PENETRATIONS. SEAL WITH FIRESTOPPING TO MAINTAIN FIRE RATING.8.INSULATE PIPING AND DUCTWORK. PROVIDE VAPOR BARRIERON INSULATED PIPING OPERATING BELOW 60 DEGREES F.9.TEST ALL SYSTEMS FOR PROPER OPERATION.10.COMMISSION AND BALANCE SYSTEMS.11.INSTRUCT OWNER'S PERSONNEL IN PROPER OPERATION OF SYSTEMS.SECTION 07901 - JOINT SEALANTSSUMMARY:1.PROVIDE JOINT SEALERS AT INTERIOR AND EXTERIOR VERTICAL AND HORIZONTAL JOINTS.SUBMITTALS:1.SUBMIT PRODUCT DATA AND MOCKUP OF EACH JOINT TYPE.PRODUCTS:1.ACRYLIC URETHANE JOINT SEALANT:A.ONE PART, ASTM C 920, EXTERIOR AND INTERIOR USE.B.PRODUCT: BENJAMIN MOORE, MOORLASTIC LIFETIME, WHITE 465-01,AND/OR COLOR AS APPLICABLE; OR APPROVED EQUAL.2.OTHER AS REQUIREDINSTALLATION:1.COMPLY WITH REQUIREMENTS OF SECTION 01000 - PROJECT REQUIREMENTS.2.TEST SEALANT ADHESION FOR EACH SUBSTRATE REQUIRED.3.INSTALL IN PROPER RELATION WITH ADJACENT WORK.4.CLEAN ADJACENT SURFACES SOILED WITH SEALANT IMMEDIATELY.SECTION 083200 - VINYL SLIDING PATIO DOORSSUMMARY1.PROVIDEA.VINYL SLIDING PATIO DOORSSUBMITTALS:1.SUBMIT PRODUCT DATA, SAMPLES, SHOP DRAWINGS, WARRANTY.PRODUCTS:1.PRODUCTS: HARVEY . SEE DOOR SCHEDULE / SALES REP.2.NWWDA QUALITY STANDARDS FOR STILE AND RAIL DOORS: NWWDA I.S.6.3.EXTERIOR STOCK STILE AN RAIL DOORS:A.QUALITY STANDARD: NWWDA I.S.6.B.PANEL CONFIGURATION: SEE ELEVATIONS.C.GLAZING: LOW-E INSULATING GLASS -- ARGON FILLEDD.GLAZING COLOR: CLEAR GLASS. VWOE.CLAD: COLOR. SEE DOOR SCHEDULE OR OWNER.F.SCREENS, DOOR HARDWARE PER MANUF./ OWNERG.FLASHING PER MANUF. / PER MANUF. RECOMMENDATIONS.INSTALLATION:1.COMPLY WITH REQUIREMENTS OF SECTION 01000 - PROJECT REQUIREMENTS.2.COMPLY WITH NWMA IS-1 QUALITY STANDARDS.3.COMPLY WITH NFPA 80 FOR RATED ASSEMBLIESREVISION SCHEDULENo. Date Description
UPUPA-201A-202A-2022A-2011121A-3011A-30113' - 8 1/4"2' - 9 7/8"10' - 8"2' - 9 7/8"4A-3022A-3012A-301BASEMENT00124' - 0"30' - 0"54' - 0"TCO4' - 0"12' - 8"24' - 0"30' - 0"C.O.-TOC: 154.0824' - 0"1' - 4"R @0' - 7 11/32"1454' - 0"6' - 8"10' - 8"6' - 8"14' - 0"16' - 0"9' - 10"7' - 2"6' - 6"6' - 6"INSTALL PASSIVE ORACTIVE RADON REDUCTIONSYSTEM PER IRC/780 CMRFDN. DRAINAGE SYSTEM AS / IF REQUIREDPER IRC / 780 CMR TYP.4" THK REINCONC SLABTYPICALTOC: 147.75BEAMPOCKETPER ENGDWGSDROPPEDBEAM ABVPER ENG.0' - 8"0' - 8" THK.DIF5' - 0"4' - 2"2A-302UNEXCAVATED(GARAGE)NOTE: SEE ENGINEER'S DRAWINGSFOR STRUCTURAL INFO TYPICALS/CNOTE:INSTALL NFPA 13D FIRE SUPPRESSIONSYSTEM TYP.DECK15' - 6"1' - 0"HEATPUMP(VIF)LANDING /STAIR ABOVEFACE OFPT 6X6 PT POSTTYPICALDECK LINEABOVE TYP.NOTE: TOP OF SHEAPRECAST (PC) 8" SQ. ANDFIN. COL. 8" SQ. TYP.OF 4FTG PERENG. TYP. T. TYP.0' - 9"VERIFYSPOT EL.IN. FIELDTYPICALDECK12' - 0"5' - 8"25' - 8"DIFSTEPFTG. ASREQ.STEPFTG. ASREQ.8' - 2"001-ACONC RTN1' - 4"FDN &AB'S PERENGINEERTYPICAL0' - 10"MID-SPANCARRIAGESUPPORTIF REQ. PERENGINEERPOSTPERENG.1' - 4"31' - 4"25' - 4"1' - 4"1' - 4"1' - 4"6' - 0"8' - 8"2X4 STUD WALLW/ CC SPRAY FOAM TYP.(NOT SHOWN - SEESECTION DETAILS)DECK OFFSET0' - 4 1/4"13' - 4"1' - 10"CONC. OPG.9' - 8"1' - 0"CONC. OPG.9' - 8"1' - 10"DECK5' - 0"CONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:16:08 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTBasement /Foundation PlanA-101PERMIT-CD3/03/20203/03/20202018.19412 1/4" = 1'-0"10.0 BSMT0'2'4'8'16'@ CONC. OPENINGREVISION SCHEDULENo. Date Description
UPDNREF.DWA-201A-202A-2022A-20111254' - 0"6' - 8"10' - 8"6' - 8"1A-3011A-3015' - 5"1' - 11"0' - 6"2' - 10"2' - 8"4' - 0"12' - 8"4A-302HALL101PWD RM102FAMILY103DINING104KITCHEN1052A-3012A-30124' - 0"1' - 4"DECK15' - 6"1' - 0"54' - 0"8' - 11"15' - 1"VIF5' - 9"16' - 1"8' - 2"3' - 6"24' - 0"30' - 0"4' - 10"5' - 8"13' - 8 1/4"2' - 9 7/8"10' - 8"2' - 9 7/8"5' - 8"21' - 10"3' - 10"2-CAR GARAGE106104-AC102-A101-BAA101-C105-AA101-A24' - 0"30' - 0"7' - 0"3' - 6"3' - 6"16' - 0"DECK12' - 0"STAIR5' - 0"4" THK. REIN.CONC. SLABTYPICALSLOPER @0' - 7 5/32"15KITCHEN PLANPER KIT.DESIGNERTYP.DROPPED BM ABV.----2A-302S/CHHCLEAR3' - 0 1/2"3A-301STAIR / HANDRAILS /GUARD PER IRC/780 CMR TYP.1' - 8 1/2"12' - 9"0' - 11"11' - 0"BEAM12' - 0"2' - 5"YSTAIR / HANDRAILS /GUARD PER IRC/780 CMR TYP.R @0' - 6 1/2"46' - 10"DECK5' - 0"PTPOSTPER ENG.PTPOSTPER ENG.PORCHROOFLINE ABOVE0' - 9" T TYP.DPENTROOFABOVE6' - 8"10' - 8"6' - 8"106-B106-AB5' - 4"5' - 4"25' - 4"1' - 4"31' - 4"32' - 8"DECK OFFSET0' - 4 1/4"DECK13' - 4"CONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:16:10 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTFirst Floor PlanA-102PERMIT-CD3/03/20203/03/20202018.19512 1/4" = 1'-0"11.0 FLR0'2'4'8'16'REVISION SCHEDULENo. Date Description
DNDWA-201A-202A-2022A-20111224' - 0"30' - 0"14' - 2"2' - 4"14' - 10"1A-3011A-30154' - 0"2' - 2"12' - 8"4A-3029' - 4 1/2"16' - 0"0' - 0"8' - 9"15' - 3"BRM 4 / OFFICE204BRM 3203BRM 2202BATH205M.BATH207M.WIC 12082A-3012A-30154' - 0"8' - 11"28' - 7 1/2"12' - 8"7' - 0 1/2"4' - 5"4' - 11 1/2"M.WIC 2209SUPER INSULATEPLBG (GAR. BELOW)2' - 2"12' - 0"XUUV205-A207-A208-AZV209-A10' - 1"1' - 3"2' - 0"2' - 5"2' - 7 3/4"HOLD6' - 11 1/4"2' - 2"2' - 5"9' - 7"6' - 8"3' - 10"1' - 2"2' - 4"3' - 10"2' - 7"3' - 2"6' - 5"36X60SHWR30X60TUB/SHWRATTICACCESSCATHEDRALCLG ABV.7' - 10"8' - 2"2A-302S/CSSS1/2 WALLGUARD PERIRC/780 CMR3A-30130' - 0"FOS6' - 10"2' - 6"8' - 8"2' - 6 1/4"2' - 9 7/8"10' - 8"2' - 9 7/8"X4' - 4"4' - 4"ROOFBELOWTYPICALBLDG. LINE /KNEE WALL72" L. .DBL. SINKVANITY +FILLERS60" L. SINGLESINK VANITY+ FILLERSS203-A203-BM. BRM206206-A202-A202-B204-AHALL201201-A205-B207-B2' - 4"CANT.GABLELINEABOVE12' - 6"1' - 0"2' - 6"4' - 5"GABLE PROJ. ABV.0' - 6"4' - 3"3' - 0"VIF7' - 3"204-BHOLD5' - 11 1/4"3' - 7 3/4"1' - 6"U5' - 5 7/8"5' - 2 1/8"3' - 3"12' - 0"1' - 4"24' - 0"1' - 4"31' - 4"1' - 2" PENT RF.PENT RF. 1' - 2"PENTROOFBELOWFOS @DORMER6' - 8"10' - 8"6' - 8"SMALL GABLEWALL OVERHANGABOVECONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:16:13 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTSecond Floor PlanA-103PERMIT-CD3/03/20203/03/20202018.19612 1/4" = 1'-0"12.0 FLR0'2'4'8'16'REVISION SCHEDULENo. Date Description
UPDNDN931 SFAreaBuilding Area LegendGross Building Area1511 SFArea1A-3011A-3012A-3012A-3019:129:129:120' - 10"0' - 10"0' - 10"0' - 10"0' - 10"0' - 10"4.25:12METAL GUTTER TYP.BLDG LINE TYP.SHED DORMER ROOFDECORATIVERAKE BELOW9:126-INCH EAVE OVERHANG4-INCH RAKE OVERHANGOF PORCH ROOFBELOWINSTALL ICE & WATERSHIELD ENTIRE ROOFW/ CDX PWD SHTH. TYP.OPTION: ZIP ROOF SHTH, TAPE SEAMS,FLASH VALLEYS, EAVES & RIDGES(PER MANUF. RECOMMENDATIONS TYP.)ASPHALTSHINGLEROOF, INSTALLPER MANUF.RECOMMENDATIONSTYPICALMIN. RAKE@ DORMERNOTE:SECTION LINESHIFT(ANNOTATION)6:12GABLE WALLLINE (ABOVE2ND FLR.BAY WINDOW)METALGUTTERTYPICAL2ND FLRWIN. BAYBELOWGABLE WALLMET. GUTTERTYP.RAKE PROJ. @ GABLE0' - 10"0' - 6"GABLE DORMER ROOFBLDG LINE ATSHED DORMER9:12MET. GABLE0' - 10"9:129:129:12MET. GUTTER@ GABLE RF.(PENDINGGC)0' - 10"0' - 10"1' - 8"1' - 8"NOTE: WIDE EAVEOVERHANGCONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:16:17 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTRoof & Area PlansA-104PERMIT-CD3/03/20203/03/20202018.19712 1/8" = 1'-0"11.0 FLR 1/8" = 1'-0"22.0 FLRArea Schedule (Gross Building-Living Area)Name Level Area Perimeter CommentsArea 1.0 FLR 931 SF 133' - 11"Area 2.0 FLR 1511 SF 180' - 6 1/2"Grand total: 2 2442 SF 1/4" = 1'-0"34.0 RF0'2'4'8'16'REVISION SCHEDULENo. Date Description
1.0 FLR156' - 4"2.0 FLR165' - 3 1/8"2.0 FLR165' - 3 1/8"3.0 RF184' - 9 1/2"0.0 BSMT147' - 9"0.0 TOF147' - 3"0.0 BOF146' - 5"0.0 FDN155' - 1"1.0 PLT164' - 5 1/8"1.0 PLT164' - 5 1/8"8' - 1 1/8"2.0 PLT172' - 11 5/8"7' - 8 1/2"1A-3011.5 PLT168' - 3 1/8"2A-3011.0 GAR153' - 6"101-A3.0 ATTIC173' - 6 7/8"2A-3023A-3011X41X10 PVCRAKE TYP.XSTEP FTG.AS REQ.912912912PENTROOFVINYL CLPBRDSIDINGVINYL SHINGLESIDING AT GABLES9:12VINYL SHINGLESIDING @ BAY(INCLUDINGRETURN)R912912NOTE: WIN. HDR. HT.5' - 8" VIFDXB9:126:129:129:129:12PENT ROOFSPENTROOFBEYOND2.0 FLR165' - 3 1/8"0.0 FDN155' - 1"1.0 PLT164' - 5 1/8"2.0 PLT172' - 11 5/8"1.5 PLT168' - 3 1/8"1.0 GAR153' - 6"4.25129:129121X41X10 PVC TYP.YVERT. LATTICE TYP.STEP FTG EA. SIDE IAS REQ.VINYL CLAPBRD SIDINGTYPICALFAMILYBAY RETURNBEYONDVINYL SHINGLE SIDING6129:129129:129:122' - 11"PENT ROOF (SEE 2ND FLR PLAN)106-B106-AUCONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:17:59 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTBuildingElevationsA-201PERMIT-CD3/03/20203/03/20202018.19812 1/4" = 1'-0"1EAST - FACADE 1/4" = 1'-0"2SOUTH0'2'4'8'16'REVISION SCHEDULENo. Date Description
1.0 FLR156' - 4"2.0 FLR165' - 3 1/8"3.0 RF184' - 9 1/2"1.0 PLT164' - 5 1/8"2.0 PLT172' - 11 5/8"1A-3012A-3017' - 8 1/2"8' - 1 1/8"1.0 GAR153' - 6"4.25:12XVVZAC104-A3.0 ATTIC173' - 6 7/8"VINYL SIDING TYPPER IRC/780 CMR3' - 0"ALIGN GAR. WIN. HEADW/ HOUSE WIN. 1ST FLR.STEP FTGAS REQ. TYP.STONE RETWALL AS REQ.STONE RETWALL AS REQ.0.1 BOF142' - 11"0.1 TOF143' - 9"0.1 FDN147' - 9"001-A9129122.0 FLR165' - 3 1/8"3.0 RF184' - 9 1/2"0.0 FDN155' - 1"1.0 PLT164' - 5 1/8"2.0 PLT172' - 11 5/8"4A-302UUAAT9:123.0 ATTIC173' - 6 7/8"VINYL CLPBRD. SIDING TYPSTEPPEDFTG ASREQUIREDVINYLSHINGLERETURN@ BAY1X10 PVCBASE TRIM@ BAY612PORCHSLOPEBEYONDCONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:19:36 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTBuildingElevationsA-202PERMIT-CD3/03/20203/03/20202018.19912 1/4" = 1'-0"1WEST 1/4" = 1'-0"2NORTH0'2'4'8'16'REVISION SCHEDULENo. Date Description
1.0 FLR156' - 4"2.0 FLR165' - 3 1/8"3.0 RF184' - 9 1/2"0.0 BSMT147' - 9"0.0 TOF147' - 3"0.0 BOF146' - 5"0.0 FDN155' - 1"1.0 PLT164' - 5 1/8"2.0 PLT172' - 11 5/8"CONC. POUR7' - 10"AANOTE: SECTIONLINE SPLIT IN PLANS7' - 8 1/2"8' - 1 1/8"BATH205BRM 4 / OFFICE204KITCHEN105HALL101BASEMENT0013.0 ATTIC173' - 6 7/8"ATTIC3011' - 3"FIREBLOCKSTAIR PERIRC/780 CMRTYPICALSTAIR /HANDRAIL /GUARD PERIRC/780 CMRTYPICALDROPPEDLVL CARRYINGBEAM PERENG. TYP.SEEWALL SECT.FOR WALL /PORCH /BAY DETAILCLR. MIN.6' - 8"2" XPS VERT. @@ SLAB PERIMETERTYP.0.1 BOF142' - 11"0.1 TOF143' - 9"0.1 FDN147' - 9"NOTE:FLOOR JOISTPER ENG. TBD(LEVEL SPOT ELEVATIONSPENDING TYPICAL)CLR. MIN.6' - 8"2.0 FLR165' - 3 1/8"2.0 FLR165' - 3 1/8"0.0 FDN155' - 1"1.0 PLT164' - 5 1/8"1.0 PLT164' - 5 1/8"2.0 PLT172' - 11 5/8"1.5 PLT168' - 3 1/8"1.0 GAR153' - 6"4.25122-CAR GARAGE106155.085/8" TYPE X GWBTYPICALDROPPEDLVL RIDGEBM. PER ENG.LVL BM.PER ENG.CATHEDRALCLG JOIST(BOT. FLUSHW/ RIDGE BM.)A-3013AZ6' - 8"LVL HDR PER ENG.(RAFTERS BEARING ON SINGLE2X6 PLATE @ WINDOW HEADERWITH HURRICANE CLIPS)M.WIC 22097' - 8 1/2"DR2.0 FLR165' - 3 1/8"2.0 FLR165' - 3 1/8"1.0 PLT164' - 5 1/8"1.0 PLT164' - 5 1/8"2.0 PLT172' - 11 5/8"2.0 PLT172' - 11 5/8"1.5 PLT168' - 3 1/8"1.5 PLT168' - 3 1/8"VINYLSOFFITTYP.ZIP SHEATHING1/2 GWB2-CAR GARAGE106M.WIC 22091X8PVC/COMPOSITE5/8" TYPE X6" CC INSUL.PER IRCCC INSUL.PER IRC /HERS RATER3/4" T&GADVANTECHFLR SHTH. TYP.TOP OFGAR. ROOFLVL BEAM3' - 0"INSUL.WIN. HDR.PER ENG.DORMER @WICCC INSUL.PER HER CONSULT.PLATE & RAFTERBEYONDVIF5' - 8"0' - 4 1/2"LOWERPLATE FORGABLERPENTROOF912912CONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:19:41 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTBuilding SectionsA-301PERMIT-CD3/03/20203/03/20202018.191012 1/4" = 1'-0"1Section 1 1/4" = 1'-0"2Section 20'2'4'8'16' 1/2" = 1'-0"3GARAGE SOFFIT / WIC DORMER DTLREVISION SCHEDULENo. Date Description
1.0 FLR156' - 4"2.0 FLR165' - 3 1/8"0.0 BSMT147' - 9"0.0 TOF147' - 3"0.0 BOF146' - 5"0.0 FDN155' - 1"1.0 PLT164' - 5 1/8"2.0 PLT172' - 11 5/8"3.0 ATTIC173' - 6 7/8"7' - 8 1/2"BASEMENT001HALL101BRM 4 / OFFICE204ATTIC301VINYLSOFFIT1X8 PVC / COMPOSITETRIM (BLKG. AS REQ)1/2 ZIPSHEATHINGTYP.SOLID BLKG. :AS SPRAY INSUL. DAMTYP. @ CANT. J.2"RIGIDINSUL@ HDRTYP.HDR. PER ENG.2-2X PTBAND JOIST@ DECK TYP.DOOR HDR.PER ENG.BEAM PERENGINEERPORCHRAFTERS / DTLS.PER ENG.(2X8s)CANTILERJOIST /SOLID BLKG.PERENGINEER10 MIL. VB2" XPS CONT.RIGID INSUL. TYP.CANT.ATTICFLR. J.PER ENG.PENT ROOFLINE BEYOND0' - 6"CANTILEVEREDGABLE WALLBEAMPER ENG.0' - 10"6129:12X101-A8' - 1 1/8"PORCH DECK0' - 5"FLOORJOISTPERENGINEERTBD TYP1' - 3"1/2" THK. GWB(THERMAL BARRIERPER IRC/780 CMR)R-20 CCINSUL. @ 2X4 STUDS @16" OC, 1" CLR. OF CONC.TYPICAL2X4 PTPLATER-26 CC W/IGNITIONBARRIERPER IRC TYP.R-38 CC INSUL.@ FLR FRAMING(IGNITION BARRIERPER IRC/780 CMR)R-50 CC INSUL.W/ IGNITION BARRIERPER IRC/780 CMRR-26 CC INSUL.TYP.R-26 CC INSUL.APPLY IGNITIONBARRIER PER IRC/780 CMR(WELD TO STUD WALL)DAMP PROOFING& PROTECTION / DRAINAGEBOARD PER IRC/780 CMRTYPICAL OF FDN WALLSCONC. FDN. PERENGINEER'SDWGS TYPICALFRAMING / DETAILSPER ENGINEER'SDWGS TYPICALFLASHINGPER IRC/780 CMRTYPICALXPS &FGL. BATTINSUL. @CANT.FLASHING PER IRCTYPICAL1.0 FLR156' - 4"2.0 FLR165' - 3 1/8"0.0 BSMT147' - 9"0.0 TOF147' - 3"0.0 FDN155' - 1"1.0 PLT164' - 5 1/8"8' - 1 1/8"HALL1012-CAR GARAGE106BASEMENT0012X6 PTSILL5/8" TYPE X GWBTYPICALINCLUDE TOP FLUSH1-1.75 X 14 LVL3-SIDES OF LANDING'SR.O. : OFFSET2-2X12s FOR LVLs2-2X12PER ENG.TBD2X8 NAILER W/ J.HGRS.(ATTACH PER IRC / ENG)0' - 6"5/8" TYPE XGWB UNDERLANDING,TREADS &RISERSTYPICALFUR W/1/2"FWB TYP.THERMAFIBERBATT INSULATION TYPLVL BEAMPER ENG.HANDRAIL PERIRC/780 CMR2-2X8BLOCKING -INSUL. DAMM.WIC 1208NOTE: STAIR PERIRC/780 CMRPT 2X10 MIL. VB TYP.2" THK. VERT.XPS @ SLABPERIMETERR-20 CC INSUL. IN2X4 STUDS @16" OC, 1" CLR. OF CONC.TYP.DAMP PROOFINGTYP. W/PROTECTION BRD.1/2" THK. GWB(THERMAL BARRIERPER IRC/780 CMR) TYP.R-26 CC INSUL.R-38 CC INSUL.2" THK.CONT. XPSRIGID INSUL. TYP.CONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:19:44 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTWall Sections &DetailsA-302PERMIT-CD3/03/20203/03/20202018.191112 1/2" = 1'-0"2PORCH / BAY 1/2" = 1'-0"4SECT. @ GAR STAIR / HOUSE ENTRYREVISION SCHEDULENo. Date Description
CONSULTANTSPROJECTOWNERSHEET TITLEProject PhaseProj Issue DateProject No.COPYRIGHTWilliam Frangos Architect 2020SHEET ISSUE DATE:SHEETOFWilliam Frangos100 Cummings Center, Suite 426-GBeverly MA 01915-6111978 927 9419978 927 9417 faxArchitect76 OAKVILLE ST, LYNN MA 01905McBrie, LLCSTRUCTURAL DESIGN & SALES160 SYLVAN ST, DANVERS MA 01923978 646 0097978 646 0087 faxJSRADAPTIVE ENERGY SOLUTIONS, LLC6 PILGRIM RD, S. HAMILTON MA 01982978 468 0297SALEMMASSACHUSETTS3/4/2020 12:19:46 PMC:\Users\WF\Documents\AR REVIT\2018.19 Woodlands Sub\2018.19 02-South Ridge Cir 20.02.21 CDP.rvtPROPOSEDHOUSE 2 SOUTHRIDGE CIRCLEWOODLANDS REALTY TRUSTSchedulesA-601PERMIT-CD3/03/20203/03/20202018.191212Door ScheduleDoorNumberTo Room: Name Rough Width Rough HeightFamily Width Height Manufacturer Model Frame Type Fire Rating DescriptionFinishDoor Frame Comments001-A BASEMENT 8' - 0 1/4" 6' - 10 1/2" Sliding-2 panel 7' - 11 3/4" 6' - 10" HARVEY101-A HALL 5' - 4 3/8" 6' - 10 1/2" Single-Raised Panel with Sidelights 3' - 0" 6' - 10" THERMA-TRU SMOOTH-STARS210101-B HALL Double-Flush 3' - 6" 6' - 8"101-C HALL Single-Flush 2' - 8" 6' - 8" 1/3 HR102-A PWD RM Single-Flush 2' - 4" 6' - 8"104-A DINING 8' - 0 1/4" 6' - 10 1/2" Sliding-2 panel 7' - 11 3/4" 6' - 10" HARVEY105-A KITCHEN Single-Flush 2' - 6" 6' - 8"106-A Overhead-Sectional-Flush 9' - 0" 7' - 0"106-B 2-CAR GARAGE Overhead-Sectional-Flush 9' - 0" 7' - 0"201-A HALL Double-Flush 5' - 0" 6' - 8"VENT DR. ASREQUIRED202-A BRM 2 Single-Flush 2' - 6" 6' - 8"202-B BRM 2 Double-Flush 4' - 0" 6' - 8"203-A BRM 3 Single-Flush 2' - 6" 6' - 8"203-B BRM 3 Double-Flush 4' - 0" 6' - 8"204-A BRM 4 / OFFICE Single-Flush 2' - 6" 6' - 8"204-B BRM 4 / OFFICE Double-Flush 4' - 0" 6' - 8"205-A BATH Single-Flush 2' - 4" 6' - 8"205-B BATH Double-Flush 2' - 6" 6' - 8"206-A M. BRM Single-Flush 2' - 6" 6' - 8"207-A M.BATH Single-Flush 2' - 6" 6' - 8"207-B M.BATH Single-Flush 1' - 8" 6' - 8"208-A M.WIC 1 Single-Flush 2' - 6" 6' - 8"209-A M.WIC 2 Single-Flush 2' - 6" 6' - 8"Grand total: 23Window ScheduleType Mark Count Rough Width Rough Height TypeUNITManufacturer Model Material FinishGlazingHeadHeightCommentsWidth Height Thickness TypeA 3 2' - 11 1/2" 4' - 9 1/2" Double Hung with Trim 2' - 11" 4' - 9" HARVEY 2946 6' - 10"B 1 8' - 7" 4' - 9 1/2" Double Hung-Triple w Trim 8' - 6 1/2" 4' - 9" HARVEY 2946-3 6' - 10"C 1 4' - 0 1/2" 3' - 0 1/2" Awning with Trim 4' - 0" 3' - 0" HARVEY AWN 6' - 10" Custom Awning SizeD 1 5' - 9 1/4" 4' - 9 1/2" Double Hung-Double w Trim 5' - 8 3/4" 4' - 9" HARVEY 6' - 10"R 3 Awning with Trim 2' - 6" 2' - 6" HARVEY AWN 5' - 8" Custom Mulled Units (R.O.TBD)T 1 Basement-Awning 2' - 8" 1' - 7" MONARCH BW 2817 0' - 0" ENERGY STARU 3 2' - 11 1/2" 4' - 5 1/2"Double Hung with Trim 2' - 11" 4' - 5" HARVEY 2942 6' - 8"V 2 2' - 11 1/2" 3' - 5 1/2" Double Hung with Trim 2' - 11" 3' - 5" HARVEY 2932 TEMPERED 6' - 8"X 3 5' - 9 1/4" 4' - 5 1/2" Double Hung-Double w Trim 5' - 8 3/4" 4' - 5" HARVEY 2942-2 6' - 8"Y 1 2' - 6" 4' - 9 1/2" Double Hung with Trim 2' - 5 1/2"4' - 9" HARVEY 2446 6' - 10"Z 1 8' - 7" 4' - 5 1/2" Double Hung-Triple w Trim 8' - 6 1/2" 4' - 5" HARVEY 2942-3 6' - 8"Grand total 20Room Finish ScheduleRoomNumberRoom NameFinishArea Perimeter CommentsFloor Base Wall CeilingCeilingHeight001 BASEMENT797 SF 116' - 10"101 HALL117 SF 63' - 5 11/16"102 PWD RM31 SF 22' - 4 1/2"103 FAMILY289 SF 69' - 8 7/16"104 DINING190 SF 54' - 7 3/32"105 KITCHEN167 SF 52' - 5 1/2"106 2-CAR GARAGE 567 SF 104' - 9 1/2"201 HALL87 SF 52' - 3 1/2"202 BRM 2189 SF 57' - 7"203 BRM 3229 SF 61' - 8 3/8"204 BRM 4 / OFFICE 134 SF 49' - 7"205 BATH70 SF 40' - 7 1/2"206 M. BRM267 SF 76' - 4 1/2"207 M.BATH91 SF 46' - 1"208 M.WIC 144 SF 26' - 7 27/32" AREA / PER. AT 5-FT HT.209 M.WIC 2127 SF 51' - 11 3/8" AREA / PER. AT 5-FT HT.301 ATTIC360 SF 84' - 0 5/32" AREA / PER. AT 5-FT HT.DOOR SCHEDULE NOTES:1. DOOR MODEL / MANUFACTURER AS SELECTED BY OWNER. INTERIOR DOOR PANELSSHOWN IN PLANS DO NOT MATCH CURRENT DR. MODELS SELECTED. SEE MANUFACTURER.2. MIN. DOOR SIZE AND FIRE-RATING PER 780 CMR / IRC AND APPLICABLE CODES.3. DOOR AND TEMPERED GLAZING PER 780 CMR / IRC AND APPLICABLE CODES.4. DOOR LOCATION AND OPERATION PER 780 CMR / IRC AND APPLICABLE CODES.5. VERIFY BUILDING SITE NOT IN WIND-BORNE DEPRIS REGION: IF SO, PROVIDE IMPACTGLAZING OR OTHER ALLOWED METHOD PER IRC / 780 CMR AS SELECTED BY OWNER.FINISH SCHEDULE NOTES:1. FINISH SELECTION BY OWNER AND CONTRACTORPER 780 CMR / IRC AND APPLICABLE CODES.WINDOW SCHEDULE NOTES:1. PROVIDE TEMPERED GLAZING AS REQUIRED PER APPLICABLE CODES.2. PROVIDE EGRESS WINDOWS AS REQUIRED PER APPLICABLE CODES.3. PROVIDE APPROVED EMERGENCY RELEASE OPENING LIMITING DEVICE PER APPLICABLE CODES.4. STRUCTURAL MULLED WINDOWS AS REQUIRED BY MANUFACTURER FOR DESIGN PRESSUREREQUIRED PER IRC / 780 CMR.5. SEE MANUFACTURER FOR ROUGH OPENING DIMENSIONS.6. SEE EXTERIOR BUILDING ELEVATIONS FOR GRILLE PATTERNS.7. VERIFY BUILDING SITE NOT IN WIND-BORNE DEPRIS REGION: IF SO, PROVIDE IMPACT GLAZING OROTHER ALLOWED METHOD PER IRC / 780 CMR AS SELECTED BY OWNER.8. PROVIDE HURRICANE ANCHORS PER MANUF. AS REQUIRED TO SECURE WINDOW ASSEMBLEY.DOOR PANEL CONFIG.PER OWNER (TBD PER DR. MODEL)REVISION SCHEDULENo. Date Description