49 Federal St FP 6_11_20Notes: _ I: II L LJE ( 204 ) DN 0 0 0 0 1 1 I1 UNI 1,547 Living RBI ( 203 .. 0 r �L it PROVIDE 21/2" SINGLE -INLET FIRE DEPARTMENT CONNECTION (TYPE AND FINAL LOCATION TO BE VERIFIED WITH BOSTON FIRE DEPARTMENT PRIOR TO INSTALLATION). PROVIDE 2-1/2" CHECK VALVE WITH BALL DRIP LOCATED IN COMMON AREA. 1 0 0 esL1P 100B ' �� `MAIL STATIC V �_ ANNUNCIA PANEL-- CO` 1 1 ■ 2" COPPER SERVICE (DESIGNED AND INSTALLED PROVIDE NEW 1.511 PER NFPA 24 BY OTHERS) BACKFLOW PREVENTER AND STRAIGHT -PIPE RISER (SEE DETAIL, THIS SHEET) UNIT 2 1,529 SF Living Room ( 207 ) Bedroo ® ~+ 8' <°>37 O \/ + 8'"° Dinini DN.: n L Kitchen First Floor Plan SCALE: 1/4" = 1'-0" G.1 I I UNIT 1 Living Area (103) 1 CD J N CO WITH EXI TAIR A LINE OF PORCH ABOVE earoom �110. 710 Bedroom (105) Bath (107) Hall UN 106 VuV Basement Plan SCALE: 1/4" = 1'-0" Bedroom ( 109„). JASON CATALFO KAHAN FIRE PROTECTION , NO.483Et- - sTER�� 06/11/2020 REV: DESCRIPTION: BY: DATE: STATUS: CONSTRUCTION ISSUE , PLS q0INC 7 CLIENT: ENGINEER: PLS I N C 23 SAGAMORE LN BOXFORD, MA 01921 SITE: TITLE: 49 FEDERAL ST SALEM, MA 01970 FIRE PROTECTION DETAILS BASE -1ST SCALE AT Al: DATE: 1 /4"= 1 '-0" 6/ 1 1 /20 PROJECT NO: DRAWING NO: DRAWN: JK CHECKED: JK REVISION: FP 1 2020-FEDER 1 Notes: Occupancy Classification: Design Area Density: Additional Outside Hose: Design Area Size: Notes: an. WAL 4.9R 7.0 01 IN L_ edroom ( 401 ) 411' r+ 28' /, 1\ Design Area 1 TOP FLOOR Demand Calculations using Hazen -Williams Method LH 0.1 100 289.29 4.9R 7.0 0.1 +2. ' J /\ /, / / / /I I \ I 41 %, Bath UNI 0 0 0 0 Wet System .I 044 �r 4.9R 7.0 0.1 LF Bath ( 404 ) 4. Bedroo (402) 0 0 0 I 1' 11 Bedroo (408) LF Bath C 409 CL Bedroom ( 406 L .44 P. 411 1410 CL I -I I I +J ALIGN LF Hal Bedroom 407 I 405 I W/D +28 + 2 8' 1 Third Floor Plan SCALE. 1 /4" = 1'-0" UNIT 856 SF Living Roo ( 302 a r DO l +J 1 LINE OF WALL BELOW >n' 1/2 Bath W/D ( 304 ) It DN Common (301) 0 0 LJ DECK DECK .9F; -71 I=1 7 4.9R r I )17 I 11 0UP 41 18' J UNIT 3 890 SF Living Room ( 305 ) Calculation results for Design Area 1 This system as shown on PLS INC for MULTI -UNIT contract no - TOP FLOOR company print no at 49 FEDERAL ST is designed to discharge at a rate of 0.1 a maximum area of 289.29 ft2 whe Hose stream allowance of Occupancy classification: LH Commodity classification: Maximum storage height: Storage arrangement: Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: LINE OF WALL BELOW 1 959 SF C5)9Rig Room 0.1 W/D 1 dated 6/11/20 gpm/ft2 (L/min/m2) of floor area over n supplied with water at a rate of 48 qpm at 46.3 psi at the base of the riser. is included in the above. r 00 J 1 0 gpm 48 gpm 0 gpm 0 gpm 0gpm 48 gpm 100 qpm 148 gpm UP Ir Bath Number of heads flowing: 3 System Type: Wet Maximum velocity: 8.96 ft/s Pressure Required at Source: Pressure Available at Source: Surplus Pressure at Source: _I 1 46.3 psi 79.9 psi 33.6 psi Bedroom i Kitchen (307) Design Area 2 2ND FLOOR Demand Calculations using Hazen -Williams Method 0 Calculation results for Design Area 2 This system as shown on PLS INC for MULTI -UNIT contract no at is designed to di a maximum area of 282.66 ft2 when supplied with Hose stream allowance of Occupancy classification: LH Commodity classification: Maximum storage height: Storage arrangement: Flow from In -Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: Occupancy Classification: Design Area Density: Additional Outside Hose: Design Area Size: Notes: Second Floor Plan SCALE: 1 /4" = 1'-0" Wet System LH 0.1 100 282.66 is included - 2ND FLOOR company print no dated 6/11/20 49 FEDERAL ST scharge at a rate of 0.1 gpm/ft2 (L/min/m2) of floor area over water at a rate of 59.5 qpm at 70.9 psi at the base of the riser. in the above. 0 gpm 59.5 gpm 0 gpm 0 gpm 0 aom 59.5 gpm 100 qpm 159.5 gpm Number of heads flowing: 4 System Type: Wet Maximum velocity: 20.21 ft/s Pressure Required at Source: Pressure Available at Source: Surplus Pressure at Source: 70.9 psi 79.9 psi 9 psi JASON CATALFO KAHAN FIRE PROTECTION NO. 483 06/11 /2020 REV: DESCRIPTION: BY: DATE: STATUS: CONSTRUCTION ISSUE , PLS 1 INC CLIENT: ENGINEER: PLS I N C 23 SAGAMORE LN BOXFORD, MA 01921 SITE: TITLE: 49 FEDERAL ST SALEM, MA 01970 FIRE PROTECTION DETAILS 2ND-3RD SCALE AT Al: DATE: 1 /4"= 1 '-0" 6/ 1 1 /20 PROJECT NO: FP 2 DRAWING NO: DRAWN: JK 2020-FEDER CHECKED: JK REVISION: 1 Notes: -----� 1" NPT ( I � I 1 Tee with same outlet size as sprinkler thread size See "Important Installation Information", later in this document (Min.1 3/4 Collar 2" Mi Hole in Wall Recessed DRY-SIDEWALL DETAIL SCALE: NOT TO SCALE TABLE 8.10.7.1.3 POSITIONING OF SPRINKLER TO AVOID OBSTRUCTION TO DISCHARGE DISTANCE FROM SPRINKLERS TO SIDE OF OBSTRUCTION (A) LESS THAN 8 FT 8'-0" TO LESS THAN 10' 10' TO LESS THAN 11' 11' TO LESS THAN 12' 12' TO LESS THAN 13' 13' TO LESS THAN 14' 14' TO LESS THAN 15' 15' TO LESS THAN 16' 16' TO LESS THAN 17' 17' OR GREATER Wall Cup 1K"Min. 216" Max. MAXIMUM ALLOWABLE DISTANCE OF DEFLECTOR ABOVE BOTTOM OF OBSTRUCTION (INCHES) (B) 0 0'-1" 0'-2" 0'-3" 0'-4" 0'-6" 0'-7" 0'-9" 0'-11" 1'-2" i f l8 real 114mm1 ,4 t I rvr N41Im) 21< {60 ore) Max Hole 2' {51 nlmi Min. Hale 2's96' (75 rnm1 MAXIMUM EXTENSION Typical cenng Tile Finirluid Sedate e ■rx.=11,0..1 Cadag Tla :T Finielled Surface MAXIMUM RECESS h" Adjustment Recessed - V2732 (Drawim' not to scale) RESIDENTIAL PENDENT DETAIL SCALE: NOT TO SCALE CEIUNG 4" CLVS1 SPACE (NO,BSTRUCTIONr co A OBSTRUCTION FIGURE 8.10.7.1.3 POSITIONING OF SPRINKLERS TO AVOID OBSTRUCTION TO DISCHARGE NFPA 13 TABLE 8.10.7.1.3 + FIGURE 8.10.7.1.3 RESIDENTIAL SIDEWALL SPRINKLERS TABLE 8.10.7.1.4 POSITIONING OF SPRINKLER TO AVOID OBSTRUCTION TO DISCHARGE DISTANCE FROM SPRINKLERS TO SIDE OF OBSTRUCTION (A) LESS THAN 1'-6" 1'-6" TO LESS THAN 3'-0" 3' TO LESS THAN 4' 4' TO LESS THAN 4'-6" 4'-6" TO LESS THAN 6' 6' TO LESS THAN 6'-6" 6'-6" TO LESS THAN 7' 7' TO LESS THAN 7'-6" MAXIMUM ALLOWABLE DISTANCE OF DEFLECTOR ABOVE BOTTOM OF OBSTRUCTION (INCHES) (B) 0'-0" 0'-1" 0'-3" 0'-5" 0'-7" 0'-9" 0'-11" 1'-2" CEILING 0 EDL A OBSTRUCTION FIGURE 8.10.7.1.4 (B) POSITIONING OF SPRINKLERS TO AVOID OBSTRUCTION TO DISCHARGE NFPA 13 TABLE 8.10.7.1.4 + FIGURE 8.10.7.1.4 (B) STANDARD SIDEWALL SPRINKLERS TABLE 8.10.6.1.2 POSITIONING OF SPRINKLER TO AVOID OBSTRUCTION TO DISCHARGE DISTANCE FROM SPRINKLERS TO SIDE OF OBSTRUCTION (A) LESS THAN 1 FT 1'-0" TO LESS THAN 1'-6" 1'-6" TO LESS THAN 2'-0" 2'-0" TO LESS THAN 2'-6" 2'-6" TO LESS THAN 3'-0" 3'-0" TO LESS THAN 3'-6" 3'-6" TO LESS THAN 4'-0" 4'-0" TO LESS THAN 4'-6" 4'-6" TO LESS THAN 5'-0" 5'-0" TO LESS THAN 5'-6" 5'-6" TO LESS THAN 6'-0" 6'-0" TO LESS THAN 6'-6" 6'-6" TO LESS THAN 7'-0" 7'-0" AND GREATER MAXIMUM ALLOWABLE DISTANCE OF DEFLECTOR ABOVE BOTTOM OF OBSTRUCTION (INCHES) (B) 0 0'-0" 0'-1" 0'-1" 0'-1" 0'-3" 0'-3" 0'-5" 0'-7" 0'-7" 0'-7" 0'-9" 0'-11" 1'-2" CEIUNG A OBSTRUCTION FIGURE 8.10.6.1.2(A) POSITIONING OF SPRINKLERS TO AVOID OBSTRUCTION TO DISCHARGE NFPA 13 TABLE 8.10.6.1.2 + FIGURE 8.10.6.1.2(A) RESIDENTIAL PENDENT AND UPRIGHT SPRAY SPRINKLERS TABLE 8.3.2.5(c) TEMPERATURE RATINGS OF SPRINKLERS IN SPECIFIED RESIDENTIAL AREAS HEAT SOURCE SIDE OF OPEN OR RECESSED FRONT OF RECESSED FIREPLACE KITCHEN RANGE WALL OVEN SIDE OF CEILING OR WALL MOUNTED I IOT AIR DIFFUSER FRONT OF WALL MOUNTED HOT AIR DIFFISER HOT WATER HEATER OR FURNACE LIGHT FIXTURE: OW-250W LIGHT FIXTURE: 250W-499W MINIMUM DISTANCE FROM EDGE OF MINIMUM DISTANCE FROM EDGE SOURCE TO ORDINARY TEMPERATURI: OF SOURCE TO INTERMEDIATE SPRINKLER (INCHES) TEMPERATURE SPRINKLER (INCHES) FIREPLACE 36 60 18 18 24 36 6 6 12 12 36 9 9 12 18 3 3 6 TEMPERATURE RATINGS OF SPRINKLERS IN SPECIFIED RESIDENTIAL AREAS Apo., SCALE: rrts FP0.1 NTS Job: MULTI -UNIT Address: 49 FEDERAL ST City: SALEM State: MA Contract #: I Date: Contractor: PLS INC I Designer: Address: 23 SAGAMORE LN City: BOXFORD State: MA Zip/Postal Code: 01921 Phone: 617-633-3533 Fax: Email: Approving Authority: Desian Defaults Standards: NFPA13 Default Sprig Size: 1 Default Drop Size: 1 Default Sprig Material: CPVC Default Drop Material: CPVC Default Sprig Elevation: 0 Default Drop Elevation: 0 Zip/Postal Code: 01970 6/11/20 JK MAX. HANGER SPACING PIPE TYPE SCH 10,40 STEEL UL LISTED CPVC 12-0 6-0 NOMINAL PIPE SIZE (IN) 174" 1i2" 2 12-0 6-6 15-0 7-0 15-0 8-0 2Y2 ' 15-0 9-0 __{ �36" MAX. FOR 1 DIA. 48" MAX. FOR 1 1/4" DIA. 60" MAX. FOR 1 1/2" DIA. OR LARGER O / 0/ 0 0/ O I 10,' DISTANCE BETWEEN I 1 OMIT HGR ON STARTER PIPES SHALL NOT EXCEED 6' OR LESS, NO X-MAIN HGR ABOVE TABLE OMISSIONS ALLOWED IF GREATER THAN 48" MAX. FOR 1 1/4" DIA. IF GREATER THAN 36" MAX. FOR 1" DIA.}... IF GREATER THAN 60" FOR 1 1/2" DIA. OR LARGER CLOSETS (TYPICAL) EXCEPT WHERE SPECIFIED IN SECTION 6.6.4 (NFPA 13R, 2013 EDITION), SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING CONDITIONS: 1) THE AREA OF THE SPACE DOES NOT EXCEED 24 SF 2) THE LEAST DIMENSION DOES NOT EXCEED 3 FT 3) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIALS AS DEFINED IN NFPA220. NOTE: WHEN MECHANICAL EQUIPMENT OR LAUNDRY MACHINES ARE PLACED IN THE CLOSET, THE CLOSET IS NO LONGER CONSIDERED A CLOTHES CLOSET, LINEN CLOSET, OR PANTRY, SO THE EXCEPTION OF 6.6.3 IS NO LONGER VALID AND SPRINKLERS MUST BE INSTALLED. ISYM I CNT I POSITION I FINISH I • 62 I PEND BRASS UL LISTED CPVC SPRINKLER PIPING FIDE ALA' V1 S Y TAMPER SWITCH FLOW SWITCH MONITOR MODULE CONTROL MODULE ISOLATOR MODULE V130LS TEMP 155 4 15-0 6 15-0 FIRE PROTECTION NOTES: THE PURPOSE OF THIS FIRE PROTECTION DRAWING AND THE ASSOCIATED FIRE PROTECTION DESIGN NARRATIVE IS TO INDICATE THE PROPOSED COMMERCIAL SPRINKLER SYSTEM TO BE INSTALLED WITHIN THE RENOVATED MULTI -UNIT BUILDING LOCATED AT 49 FEDERAL ST IN SALEM, MASSACHUSETTS. THIS BUILDING CONSISTS OF A BASEMENT LEVEL, 1ST LEVEL, 2ND LEVEL AND 3RD LEVEL AS INDICATED ON THE ASSOCIATED ARCHITECTURAL DRAWINGS. THIS RESIDENTIAL SPRINKLER SYSTEM HAS BEEN DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13R (2013 EDITION) FOR A RESIDENTIAL BUILDING UP TO 3 STORIES IN HEIGHT AND NOT EXCEEDING 12,000 GROSS SF WITH A SINGLE MEANS OF EGRESS. THE SPRINKLER CONTRACTOR SHALL FOLLOW THE LATEST REQUIREMENTS 8 OF NFPA 13 AND 13R (2013 EDITION), MASSACHUSETTS STATE BUILDING 15-0 CODE (780 CMR, 9TH EDITION) AND SALEM FIRE DEPARTMENT REQUIREMENTS. THEN EXTEND HERE 0/3 04 COMBINATION SPEAKER/STROBE, ADA APPROVED, 30 80" AFF; 15/75 CANDELLA, SET AT 15 cd U.O.N. ON FLOOR PLANS. DESIGNATES CANDELLA RATING; WP LF FACP ANN RT O 200" ❑D TPD EXTERIOR WEATHERPROOF HORN/STROBE EXACT LOCATION AND HEIGHT PER FIRE DEPARTMENT. LF MINIHORN (GENTEX GHLF 24 VDC SERIES) FIRE ALARM CONTROL PANEL WITH BATTERY BACKUP; NOTIFIER, FCI OR APPROVED EQUAL REMOTE ANNUNCIATOR PANEL ADDRESSABLE MANUAL PULL STATION 48" AFF ADDRESSABLE SYSTEM SMOKE DETECTOR ADDRESSABLE SYSTEM CO2 DETECTOR REMOTE TEST t FACP AUTOMATIC DAMPER HEAT DETECTOR 200 Deg. fixed temp. DIGITAL UL DIALER TRANSIENT PROTECTIVE DEVICE KNOX BOX ELECTRIC BELL BEACON (OVER FDC) NOTE: NOT ALL DEVICES USED IN THIS SYSTEM PRODUCTS SHALL BE AS INDICATED OR EQUAL LOCAL HARDWIRED SMOKE LOCAL HARDWIRED SMOKE/CO THIS SYSTEM WILL BE SUPPLIED BY A NEW 2" COPPER SERVICE, TAPPED OFF THE EXISTING WATER MAIN ON ATHENS STREET. THE 2" SERVICE SHALL BE DESIGNED, INSTALLED, FLUSHED AND TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 24 BY A LICENSED UNDERGROUND CONTRACTOR AND WILL ENTER THE BASEMENT AS INDICATED ON THIS DRAWING. THE SYSTEM HAS BEEN HYDRAULICALLY CALCULATED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13R, INCLUDING THE FOUR HYDRAULICALLY MOST DEMANDING HEADS IN A SINGLE COMPARTMENT BASED ON THE REQUIREMENTS OF THE SPECIFIC SPRINKLER HEAD AND THE SPACING USED IN THIS DESIGN (16'(16' REQUIRING A MINIMUM OF 13 GPM @ 7 PSI). REMOTE AREAS, DENSITIES AND HOSE STREAM ALLOWANCES ARE INDICATED ON THIS DRAWING ALONG WITH SYSTEM DEMANDS AT CONNECTION TO STREET AND CALCULATION RESULTS HAVE BEEN COMPARED TO RECENT HYDRANT FLOW TEST INFORMATION OBTAINED FROM THE BOSTON WATER & SEWER DEPARTMENT. CALCULATIONS HAVE BEEN SUBMITTED WITH THIS DRAWING TO THE SALEM FIRE DEPARTMENT FOR REVIEW. SPRINKLER HEAD LOCATIONS HAVE NOT BEEN COORDINATED WITH CEILING -MOUNTED FIXTURES. INSTALLING SPRINKLER CONTRACTOR SHALL COORDINATE WITH ELECTRICIAN AND LOCATE SPRINKLERS AT LEAST 36" FROM THE CENTER OF ANY CEILING -MOUNTED FIXTURE, IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13R WHILE MAINTAINING THE MAXIMUM DISTANCES FROM WALLS INDICATED ON THIS DESIGN (8-FT). ADDITIONAL SPRINKLERS REQUIRED DUE TO INABILITY TO MEET OBSTRUCTION CRITERIA SHALL BE AT THE OWNERS EXPENSE. RESIDENTIAL FLAT PLATE CONCEALED PENDENT K NPT SIN MFG. 4.90 1/2" TY2234 Tyco 1. SPRINKLER CONTRACTOR SHALL TAKE PRECAUTIONS WHEN INSTALLING SPRINKLER PIPING IN JOISTS ON TOP FLOOR. GENERAL CONTRACTOR SHALL BE REQUIRED TO INSTALL SUFFICIENT INSULATION TO MAINTAIN 40-DEGREES IN ALL AREAS WHERE SPRINKLER PIPING AND HEADS ARE INSTALLED MODEL# LFII FREEZE PROTECTION INSTALLATION NOTES: ALL WORK SHALL BE PERFORMED BY A MASSACHUSETTS LICENSED SPRINKLER CONTRACTOR. THE SPRINKLER CONTRACTOR SHALL FOLLOW THE LATEST REQUIREMENTS OF NFPA 13R (2013 EDITION), MASSACHUSETTS STATE BUILDING CODE (9TH EDITION) AND THE SALEM FIRE DEPARTMENTS. THE ARCHITECTURAL BACKGROUND OF BUILDING MAY DIFFER SLIGHTLY FROM ACTUAL LAYOUT. DRAWINGS ARE NOT INTENDED TO SHOW ALL OFFSETS AND PIPING ELEVATION CHANGES. CONTRACTOR SHALL FIELD VERIFY ALL MEASUREMENTS PRIOR TO FABRICATION. CONTRACTOR SHALL HYDROSTATICALLY TEST ALL SPRINKLER PIPING AT 200 PSI FOR 2 HOURS AND IS RESPONSIBLE FOR THE COMPLETION OF ALL ABOVE GROUND TEST CERTIFICATES, SUPPLIED TO THE OWNER. ALL PIPING INSTALLED THROUGHOUT THE RESIDENTIAL AREAS OF THE BUILDING SHALL BE UL LISTED CPVC SPRINKLER PIPING.ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13 (2013 EDITION) AND ALL MANUFACTURERS INSTALLATION RECOMMENDATIONS. ALL PIPING SHALL BE PITCHED TO DRAIN WITH LOW -POINT DRAINS AT SECTIONS OF PIPING SUBJECT TO WATER TRAPPING. SPRINKLER CONTRACTOR SHALL PROVIDE PROTECTIVE PLATES WHERE CPVC PIPING IS RUN THROUGH STUDS TO PREVENT PUNCTURING OF THE SPRINKLER PIPING DURING DRYWALL INSTALLATION AS REQUIRED BY NFPA STANDARDS. ALL SPRINKLER HEADS WITHIN RESIDENTIAL AREAS OF THE BUILDING SHALL BE RESIDENTIAL PENDENT SPRINKLERS. SPRINKLERS WITHIN THE BASEMENT LEVEL WILL BE QUICK -RESPONSE UPRIGHT HEADS. ALL HEADS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS AND THE REQUIREMENTS OF NFPA 13R (2013 EDITION). THE BUILDING OWNER IS RESPONSIBLE FOR MAINTAINING THIS SPRINKLER SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 25, INCLUDING THE PROVISION OF HEAT IN ALL AREAS CONTAINING SPRINKLER PIPING AND HEADS TO PREVENT PIPE FROM FREEZING. JFP SOLUTIONS, INC. AND THE ENGINEER OF RECORD TAKE NO RESPONSIBILITY FOR ANY DAMAGES CAUSED BY FREEZE UPS. 1 y" x 2'-0 GALVI (THD BY GROOVE) THROUGH WALL 1.5" STRAIGHT -PIPE RISER ASSEMBLY WITH VANE -TYPE FLOW SWITCH, PRESSURE GAUGE, TEST AND DRAIN PROVIDE 1.5" AMES 2000B BACKFLOW PREVENTER WITH MONITORED ISOLATION VALVES esfe I°ll OF Rar .> FINISHED FLOOR 2" FIRE SERVICE PER NFPA 24 BY OTHERS) THE BUILDING OWNER IS RESPONSIBLE FOR PROVIDING HEAT IN ALL AREAS CONTAINING SPRINKLER PIPING AND HEADS TO PREVENT PIPE FROM FREEZING. ANY AREAS THAT RAISE CONCERN WITH REGARD TO FREEZING POTENTIAL SHALL BE BROUGHT TO THE ENGINEER'S ATTENTION, IN WRITING, PRIOR TO INSTALLATION. JFP SOLUTIONS, INC. AND THE ENGINEER OF RECORD TAKE NO RESPONSIBILITY FOR DAMAGES CAUSED BY FREEZE -UPS OF THE SPRINKLER SYSTEM. FIRE ALAIV \OT -S ALL FIRE ALARM SYSTEM WIRING SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE, APPLICABLE STATE AND LOCAL FIRE AND SAFETY CODES, AS WELL AS BEING COORDINATED WITH THE LOCAL AUTHORITY HAVING JURISDICTION. 2. CAUTION: DO NOT CONNECT ANY POWER TO CONTROL PANEL (BATTERIES OR 120VAC) UNTIL ALL OTHER FIELD WIRING IS TESTED AND CONNECTED. 3. DO NOT INSTALL ANY A.C. CURRENT CARRYING CONDUCTORS CLOSE TO OR IN THE SAME RACEWAY WITH FIRE ALARM SYSTEM CONDUCTORS. 4. THE ENTIRE FIRE ALARM SYSTEMS SHALL BE A CLASS "A" ADDRESSABLE SYSTEM. 5. THE RATING OF THE CONTROL MODULE (ES-200X) CONTACTS ARE: 20 WATTS AUDIO AT 25 OR 70 VOLTS 2.0 AMPS DC (BELLS, HORNS AND DC CONTROL CIRCUITS) 0.3 AMPS INDUCTIVE 6. ALL OUTPUT (SIGNAL) CIRCUITS ARE SHOWN IN ALARM CONDITION. POLARITY IS REVERSED WHEN THE SYSTEM IS IN THE SUPERVISORY CONDITION. 7. OWNER TO PROVIDE DESIGNATIONS FOR DEVICES PROGRAMMING LANGUAGE. 8. REFER TO FLOOR PLANS FOR EXACT LOCATIONS AND QUANTITY OF ALL DEVICES. 9. FIRE ALARM CONTRACTOR SHALL FIELD VERIFY THE LENGTHS AND FEASIBILITY OF ALL ROUTING BEFORE BEGINNING WORK. 10. ALL JUNCTION BOX COVERS IN THE FIRE ALARM SYSTEM SHALL BE PAINTED RED, BY THE FIRE ALARM CONTRACTOR, BEFORE THEY ARE INSTALLED. 11. ALL EQUIPMENT SHALL BE UL LISTED AND/OR FM APPROVED. 12. ELECTRICAL SUBCONTRACTOR SHALL INSTALL ALL WIRING TO THE FIRE ALARM CONTROL PANELS; TERMINATIONS TO FACP's SHALL BE MADE BY THE FIRE ALARM SUPPLIER OR UNDER SUPERVISION OF A REPRESENTATIVE FROM THE FIRE ALARM MANUFACTURER. 13. GROUND ALL EQUIPMENT PER N.E.C. REQUIREMENTS. 14. ALL PERMITS AND INSPECTION FEES SHALL BE OBTAINED AND PAID FOR BY THE FOR BY THE FIRE ALARM CONTRACTOR. 15. ALL CUTTING, PATCHING, AND CORE DRILLING FOR FIRE ALARM SYSTEMS SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. FIRE SEAL ALL NEW ELECTRICAL PENETRATIONS IN FLOORS AND WALLS. 16. THE LOCATIONS OF ALL SMOKE DETECTORS AND HEAT DETECTORS SHOWN ARE CONSIDERED TO BE SCHEMATIC ONLY. THE ACTUAL LOCATIONS (SPACING TO ADJACENT DETECTORS, WALLS ETC.) ARE REQUIRED TO MEET NFPA 72. 4\ K WOOD JOIST CONSTRUCTION RESIDENTIAL CONCEALED SPRINKLER HEAD (K=4.9) TYPICAL IXI MAINTAIN NFPA 13 OBSTRUCTION CRITERIA (TYPICAL) CPVC MAIN LOCATED WITHIN HVAC SOFFIT FEEDING BRANCHLINES LOCATED WITHIN JOIST CHANNELS (TYPICAL) �1 IxI GYPSUM BOARD CEILING ON WOOD STRAPPING TYPICAL RESIDENTIAL PENDENT SPRINKLER INSTALLATION NOT TO SCALE ELECTRIC BELL WITH BACKE 2-BOX WIRED BY OTHERS) SINGLE INLET 2.4" FIRE DEP�MEIN CONNECTION (COORDINATE VITH LOCAL FD PRIOR TO INSTALL ;TION) 1" DRAIN PIPED TO EXTERIOI SUPPLY AND RISER DETAIL NOT TO SCALE Caution: Care should be taken to ovoid compressing the insulation. This reduces its R value. To prevent potential freeze -ups of the sprinkler piping, the insulation should be installed tight against the joists. INSULATION PROTECTING SPRINKLER PIPING ON UPPER FLOOR DETAIL NOT TO SCALE FIRE ALARM NOTES & NARRATIVE THE FIRE ALARM SYSTEM FOR THIS BUILDING IS MADE UP OF THE FOLLOWING: INTERIOR FRAMING (REFERENCE ONLY) FINISHED CEILING DRY-SIDEWALL FED FROM TEE INSIDE FINISHED UNIT - OPTIONAL SOFFIT TO CONCEAL EXPOSED PORTION OF DRY SIDEWALL (COORDINATE WITH ARCHITECT AND GENERAL CONTRACTOR). NOTE: MAINTAIN SPRINKLER COVERAGE WITHIN UNIT WITH REGARD TO SOFFIT OBSTRUCTIONS EXTERIOR DECK FRAMING (REFERENCE ONLY) 7.0 DRY-SIDEWALL INSTALLED WITH DEFLECTOR 4" TO 6" BELOW UNDERSIDE OF WOOD JOIST FRAMING OF DECK INSULATED EXTERIOR WALL (SPRINKLER CONTRACTOR TO FOLLOW ALL RECOMMENDATIONS OF MANUFACTURER WITH REGARD TO INSTALLATION OF DRY-SIDEWALLS) TYPICAL DRY-SIDEWALL INSTALLATION FOR EXTERIOR OVERHANGS NOT TO SCALE AMBIENT TEMPERATURE OF PROTECTED AREA AT THE DISCHARGE END OF THE LSPRINKLER 40°F 30°F 20°F 10°F 0°F -10°F -20°F -30°F -40°F -50"F -60°F 1. FIRE ALARM CONTROL PANEL (ADDRESSABLE TYPE) LOCATED IN FRONT ENTRANCE 2. PULL STATIONS AT MAIN EGRESS LOCATIONS 3. HORN STROBE LOCATED ON SECOND LEVEL COMMON AREA AND LOW FREQUENCY SOUNDERS IN ALL APARTMENTS (70 dB MIN AT PILLOW OF SLEEPING ROOMS). 4. LOCAL SMOKE DETECTORS IN ALL BEDROOMS AND COMBINATION SMOKE AND CARBON MONOXIDE DETECTORS WITHIN 10-FT OF ALL BEDROOM DOORS, INTERCONNECTED WITHIN UNIT. 5. SYSTEM SMOKE DETECTORS IN ALL COMMON AREAS 6. FLOW AND TAMPER SWITCHES FOR SPRINKLER SYSTEM. TAMPER SWITCH SHALL BE TROUBLE ONLY ON THE FIRE ALARM PANEL AND SIGNAL SENT VIA RADIO SIGNAL (WILL NOT TRIP MASTER BOX) 7. ELECTRIC BELL LOCATED ON OUTSIDE OF THE BUILDING NEAR FIRE ALARM CONTROL PANEL AND FIRE DEPARTMENT CONNECTION 8. KNOX BOX AT MAIN ENTRANCE 9. CARBON MONOXIDE DETECTOR SHALL BE LOCATED IN ALL AREAS THAT CONTAIN FOSSIL FUEL AND ADJACENT AREAS AND CONNECTED TO THE FIRE ALARM SYSTEM. TROUBLE ONLY ON FIRE ALARM PANEL AND SIGNAL SENT VIA RADIO SIGNAL (WILL NOT TRIP MASTER BOX). SYSTEM OPERATION THE ACTIVATION OF ANY MANUAL FIRE ALARM STATION OR THE AUTOMATIC ACTUATION OF ANY SYSTEM SMOKE DETECTOR, SPRINKLER SYSTEM WATER FLOW SWITCH OR ANY OTHER APPROVED ALARM INITIATION DEVICE SHALL IMMEDIATELY RESULT IN THE FOLLOWING: 1. THE DEVICE IN ALARM SHALL BE LISTED ON A DISPLAY AT THE FIRE ALARM PANEL AND REMOTE ANNUNCIATOR 2. THE AUDIBLE HORNS SHALL SOUND A TEMPORAL PATTERN AT ALL LOCATIONS 3. ALL VISUAL ALARM SIGNALS SHALL FLASH AT A RATE OF 120 FLASHES PER MINUTE. 4. IF ALARM SIGNALS ARE SILENCED FOR ANY REASON, THEY SHALL AUTOMATICALLY RESOUND IF ANOTHER ADDRESS IS TRIPPED 5. OUTDOOR BEACON LIGHTS WILL ILLUMINATE 6. IN THE EVENT OF A COMMERCIAL POWER INTERRUPTION, THE SYSTEM SHALL AUTOMATICALLY TRANSFER TO AN EMERGENCY BATTERY SOURCE. THIS TIER 1 DRAWING IS FOR DIAGRAMMATICAL USE ONLY. FIRE ALARM CONTRACTOR TO SUBMIT TIER II SHOP DRAWINGS, BATTERY CALCULATIONS AND PRODUCT CUTS TO BE REVIEWED BY JFP SOLUTIONS, INC. AND REVIEWED AND APPROVED BY THE BOSTON FIRE DEPARTMENT AND BUILDING DEPARTMENT. (4°C) (-1 °C) (-7°C) (-12°C) (-18°C) (-23°C) (-29°C) (-34°C) (-40°C) (-46°C) (-51 °C) EXPOSED BARREL AMBIENT TEMPERATUTE 40°F (4°C) 50°F (10°C) 160°F (16°C) EXPOSED MINIMUM BARREL LENGTH DIMENSION "A" (FACE OF TEE TO TOP OF CEILING OR INSIDE WALL) Inches (mm) 0 0 0 0 0 0 4 (102) 0 0 8 (203) 1 (25) 0 12 (305) 3 (76) 0 14 (356) 4 (102) 1 (25) 14 (356) 6 (152) 3 (76) 16 (406) 8 (203) 4 (102) 18 (457) 8 (203) 4 (102) 20 (508) 10 (254) 6 (152) 20 (508) 10 (254) 6 (152) f FACE OF TEE - FITTING i A MINIMUM EXPOSED BARREL LENGTH TEE FITTING ANSI B16.3 CLASS 150 OR ANSI B16.4 CLASS 125 FIGURE 3: EXPOSED BARREL LENGTH CEILING STAND-ALONE AUDIBLE APPLIANCE MANUAL FIRE ALARM BOX 90" MINIMUM • • 48" DOOR 5'-0" MAXIMUM FLOOR STAND-ALONE VISIBLE APPLIANCE OPERATING HANDLE LENS FACE OF MOUNTING SURFACE TYPICAL ESCUTCHEON COMBINATION AUDIBLE/ VISIBLE APPLIANCE 80"-96" TYPICAL MOUNTING HEIGHT DETAIL FOR WALL MOUNTED DEVICES LENS Salem District Court 19 3aral St REV: DESCRIPTION: 1949 Federal Street JASON CATALFO KAHAN FIRE PROTECTION NO. 483 06/11/2020 BY: DATE: STATUS: CONSTRUCTION ISSUE 2 PLS RO INC 7 CLIENT: ENGINEER: PLS I N C 23 SAGAMORE LN BOXFORD, MA 01921 / SITE: TITLE: 49 FEDERAL ST SALEM, MA 01970 FIRE PROTECTION DETAILS INFO SHEET SCALE AT Al: DATE: 1 /4m= 1 '-0" 6/11/20 PROJECT NO: FP 3 DRAWING NO: DRAWN: JK 2020-FEDER CHECKED: JK REVISION: 1