04-FWW Salem SR Structural Bid and Permit 6-26-2020 Stamped12'-0" EXISTING ENTRY DOOR AND SIDELIGHTS TO BE REMOVED EXISTING COLUMNS TO REMAIN EXISTING CONCRETE MASONRY WALL (CMU) EXISTING 24" OPEN WEB STEEL ROOF JOISTS AT 5'0" SPACING, SPAN FROM FRONT TO REAR WALLS +/- 16'-0" W16X36 [ +11'-4" 10" FROST WALL (TYP) 24" X 10" FOOTING (TYP)7'-0" MIN3 S1.0 NEW STEEL LINTEL. FASTEN TO BEARING PLATE W/ 1/4" FILLET WELD EACH SIDE OF BEAM FLANGE NEW 4" CONCRETE SLAB ON GRADE W/ 6X6-W1.9XW1.9 WWF PORTION OF EXISTING MASONRY WALL TO BE REMOVED. PROVIDE TEMP. SHORING AS REQUIRED PROVIDE 8' MIN. BEARING FOR NEW LINTEL ON 7"X10"X1/2" STEEL BEARING PLATE WITH (2) 1/2" HEADING STUDS. GROUT COURSES BELOW BEARING SOLID. TYPICAL EXISTING CONCRETE FOOTING. V.I.F. DRILL AND SET NEW WALL AND FOOTING REINFORCING INTO EXIST. PIER AND FOOTING, TYPICAL NEW STOREFRONT WINDOW SYSTEM, SEE ARCH. DWGS. VERIFY EXISTING FRAMING FOR TOP ATTACHMENT +/- 15'-2"+/- 4'-5"+/- 4'-5"10" CONC. SLAB ON GRADE. SEE PLAN FOR SIZE AND REINF REGS. COORD. INSULATION REQS. WITH ARCH DWGS SUITABLE SUBGRADE COMPACTED TO 95% MAX DRY DENSITY #4 DOWELS AT 48" O/C #4 BARS CONT. TOP AND BOTTOM (3) #4 BARS CONT. 7"7"3" CLR10"4'-0" MINDate Scale Job No. Date Sheet No. Mark DMA 2020 C ALL PLANS, SPECIFICATIONS AND IDEAS ARE THE PROPERTY OF DMA. RIGHTS OF USE ARE CONDITIONAL AND ARE GRANTED UNDER FULL COMPENSATION AND LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVATIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR APPLICATION IS STRICTLY PROHIBITED. ANY OTHER CONSTRUCTION OR PERMIT WITHOUT PRIOR WRITTEN PERMISSION OF DMAprepared for:STRUCTURAL PLANSlocation:Architecture - Interiors - Land Planning49 Brookview Terr. Lunenburg, MA 01462dm@dmcquaidarchitect.com978-340-5922Damon McQuaidArchitect98 ADAMS STREET SUITE 105 LEOMINSTER, MA 01453F.W. WEBB SALEMS1.0NEW ENTRY STRUCTURAL LINTEL AND FOUNDATION PLANS89 Margin Street, Salem, MA06/26/20 200203GREEN LEAFCONSTRUCTIONTHE DESIGN, CONSTRUCTION, AND QUALITY CONTROL OF ALL WORK PERFORMED ON THE PROJECT SHALL CONFORM TO THE FOLLOWING BUILDING CODE AND ALL REFERENCED STANDARDS THEREIN: 9th EDITION MASSACHUSETTS BUILDING CODE –780 CMR, EFFECTIVE OCTOBER 20, 2017. (BASED ON IBC 2015 WITH LOCAL AMENDMENTS) -GOVERNING CODE - IBC 2009 CODE REFERENCED STANDARDS INCLUDE, BUT ARE NOT LIMITED TO: ASCE 7-05 -MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES AISC 360-05 -SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS ACI 318-05 -BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE ACI 301-05 -SPECIFICATIONS FOR STRUCTURAL CONCRETE AISI 2001 -NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS -DESIGN DATA- 1. OCCUPANCY CATEGORY II 2. DEAD LOADS FLOOR DEAD LOADS ROOF DEAD LOADS 3. FLOOR LIVE LOADS: OFFICE BUILDINGS: FIRST FLOOR 100 PSF 4. SNOW LOADS: PROJECT LOCATION SALEM, MA GROUND SNOW LOAD, Pg 50 PSF FLAT-ROOF SNOW LOAD, Pf 35 PSF SNOW EXPOSURE FACTOR, Ce 1.0 SNOW LOAD IMPORTANCE FACTOR, Is 1.0 THERMAL FACTOR, Ct 1.0 • WIND LOADS: BASIC WIND SPEED (3-SEC), V 127 MPH WIND IMPORTANCE FACTOR, Iw 1.0 1. MEANS AND METHODS ARE THE CONTRACTOR’S RESPONSIBILITY. 2. STRUCTURAL CONTRACT DOCUMENTS ARE COMPLEMENTARY WITH THOSE OF OTHER DESIGN DISCIPLINES. THE CONTRACTOR SHALL PROVIDE A COMPLETE SET OF DOCUMENTS TO SUBCONTRACTORS SO THAT THEY MAY REFER TO OTHER DISCIPLINES AS REQUIRED FOR COORDINATION. 3. CONFLICTS BETWEEN STRUCTURAL DOCUMENTS AND DOCUMENTS OF OTHER DESIGN DISCIPLINES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OF RECORD (AOR) AND THE ENGINEER OF RECORD (EOR) FOR RESOLUTION. 4. THESE DRAWINGS REPRESENT THE COMPLETED PROJECT WHICH HAS BEEN DESIGNED FOR THE WEIGHTS OF THE MATERIALS INDICATED ON THE DRAWINGS AND FOR THE SUPERIMPOSED LOADS INDICATED IN THE CODE DESIGN DATA. IT IS THE CONTRACTOR’S RESPONSIBILITY TO DETERMINE ALLOWABLE CONSTRUCTION LOADS AND TO PROVIDE PROPER DESIGN AND CONSTRUCTION OF FALSEWORK, FORMWORK, STAGINGS, BRACING, SHEETING AND SHORING, ETC. ANY APPROVAL BY THE ENGINEER WILL NOT RELIEVE THE CONTRACTOR OF FULL RESPONSIBILTY, FOR SHORING AND/OR BRACING. 5. THE CONTRACTOR AND SUBCONTRACTOR SHALL REVIEW ALL ADDITIONAL DRAWINGS FOR PITS, OPENINGS, SLEEVES, CONCRETE HOUSEKEEPING PADS, INSERTS, DEPRESSIONS AND/OR OTHER SPECIFIC ITEMS NOT CALLED OUT FOR ON THE STRUCTURAL DRAWINGS. SPECIFIC ATTENTION TO THE ARCHITECTURAL AND MECHANICAL PLANS IS REQUIRED TO COVER ALL ITEMS IN BIDDING. 6. ALL OPENINGS, SLEEVES, SLOTS, ETC. NOT SPECIFICALLY DETAILED ON THE STRUCTURAL DRAWINGS MUST BE APPROVED IN THE FIELD BY THE ENGINEER'S REPRESENTATIVE. HOLES LARGER THAN 8" SHALL NOT BE FORMED OR CUT IN ANY BEARING WALL UNLESS THE EXACT SIZE, LOCATIONS, AND FRAME DETAILS HAVE BEEN SUBMITTED IN WRITING TO THE ENGINEER AND APPROVED BY THE ENGINEER. 7. ALL COSTS OF ENGINEERING INVESTIGATION AND/OR REDESIGN, DUE TO NON-CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS, SHALL BE AT THE CONTRACTOR’S EXPENSE. -GENERAL - 1. PLAN REFERENCES TO EXISTING FRAMING/CONDITIONS ARE FOR REFERENCE ONLY AND SHOULD NOT BE CONSTRUED AS ACTUAL FIELD CONDITIONS. 2. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND REPORT ANY DISCREPANCIES AND OBSERVATIONS TO THE AOR/EOR BEFORE PROCEEDING WITH ANY WORK. -EXISTING CONDITIONS - 1. CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS TO THE ENGINEER FOR APPROVAL. SUBMITTAL INCLUDE TEST REPORTS FROM A QUALIFIED TESTING AGENCY DEMONSTRATING THAT TEST RESULTS FOR TRIAL MIX BATCHES FOR EACH CONCRETE MIX DESIGN COMPLY WITH ACI 301 AND THE ADDITIONAL REQUIREMENTS OF THE PROJECT CONTRACT DOCUMENTS. 2. CONCRETE MIXES SHALL CONFORM TO ASTM C94 AND WITH THE FOLLOWING: a. PORTLAND CEMENT:ASTM C150 TYPE I OR II b. NORMAL WEIGHT AGGREGATES:ASTM C33 c. WATER POTABLE d. AIR-ENTRAINING ADMIXTURES:ASTM C260 e. WATER-REDUCING ADMIXTURES:ASTM C494, MID-RANGE TYPE A, HIGH RANGE TYPE F OR G f. ACCELERATOR ADMIXTURES:ASTM C494, TYPE C g. RETARDER ADMIXTURES:ASTM C494, TYPE D h. CORROSION INHIBITOR:ASTM C494, TYPE C CALCIUM CHLORIDE IS PROHIBITED IN CONCRETE MIXES. 3. SCHEDULE OF CONCRETE 28-DAY STRENGTHS: • LOCATION •28-DAY STRENGTH a. ELEVATED SLABS 4000 PSI b. INTERIOR SLABS ON GRADE 4000 PSI c. FOOTINGS _____ PSI d. FOUNDATIONS AND RETAINING WALLS _____ PSI e. EXTERIOR SLABS SUBJECT TO DEICERS 4500 PSI 4. STEEL REINFORCEMENT SHALL BE PLACED WITH THE FOLLOWING MINIMUM CONCRETE CLEAR COVER: a. SURFACES CAST AGAINST EARTH 3” b. SURFACES BACKFILLED WITH EARTH 2” c. SURFACES EXPOSED TO WEATHER: • #6 -#18 BARS 2" • #3 -#5 BARS 1-1/2" d. SHELTERED CONCRETE: • SLABS, WALLS, JOISTS 3/4" • BEAMS, COLUMNS 1-1/2" 5. CONCRETE SHALL BE PROTECTED FROM HOT OR COLD WEATHER AS REQ'D BY ACI 305 AND 306, RESPECTIVELY. 6. CONCRETE SHALL BE CURED BY AN APPROVED ACI METHOD. 7. CONSTRUCTION JOINTS IN STRUCTURAL CONCRETE SHALL BE LOCATED IN THE MIDDLE THIRD OF THE SPAN OR OTHER APPROVED LOCATIONS OF MINIMUM SHEAR. 8. AT CONSTRUCTION JOINTS, PROVIDE 3" X 4" TREATED BEVELED KEYS IN WALL VERTICAL JOINTS. 9. LIMIT MAXIMUM AREA BETWEEN CONSTRUCTION JOINTS AND CONTRACTION JOINTS IN SLABS-ON-GRADE TO 24-36 TIMES SLAB THICKNESS -APPROXIMATELY SQUARE. 10. NO SLEEVE SHALL BE PLACED THROUGH ANY CONCRETE ELEMENT UNLESS AUTHORIZED BY THE STRUCTURAL DRAWINGS, APPROVED SLEEVING SUBMITTAL OR SPECIFICALLY AUTHORIZED IN WRITING BY THE STRUCTURAL ENGINEER. ALL INSERTS AND SLEEVES SHALL BE CAST-IN-PLACE WHENEVER FEASIBLE. 11. CORE DRILLING SHALL NOT BE PERMITTED UNLESS AUTHORIZED IN WRITING BY THE STRUCTURAL ENGINEER. 12. SPLICES OF REINFORCEMENT SHALL BE MADE BY CONTACT TENSION LAP SPLICES, UNLESS OTHERWISE NOTED ON THE APPROVED PLACEMENT DRAWINGS OR AUTHORIZED BY THE STRUCTURAL ENGINEER IN WRITING. 13. THE CONTRACTOR SHALL TAKE MEASURES TO AVOID DRILLING OR CUTTING OF ANY EXISTING REINFORCING AND DESTRUCTION OF CONCRETE WHEN INSTALLING EXPANSION BOLTS OR ADHESIVE ANCHORS. 14. CONTRACTOR SHALL PROVIDE ADDITIONAL CONCRETE AS NECESSARY TO MAINTAIN A LEVEL SLAB SURFACE AT THE ELEVATION INDICATED. ACTUAL SLAB THICKNESS MAY VARY DUE TO BEAM AND DECK DEFLECTIONS. 15. DO NOT PLACE ANY TYPE OF CONDUITS/PIPES IN ANY ELEVATED STRUCTURAL SLAB ON DECK. 16. NO WELDING OF REINFORCING SHALL BE PERMITTED UNLESS SPECIFICALLY CALLED FOR OR APPROVED BY THE STRUCTURAL ENGINEER. 17. CONCRETE SLABS SHALL ACHIEVE 28-DAY DESIGN STRENGTH PRIOR TO THE APPLICATION OF ANY SUPERIMPOSED LOADS SUCH AS CURTAIN WALLS, MASONRY VENEERS, OR STAIRS. 18. CONCRETE STEEL REINFORCEMENT SHALL BE GRADE 60 KSI HIGH BOND DEFORMED BARS MEETING ASTM A615 REQUIREMENTS. 19. STEEL REINFORCEMENT SHOULD BE TIED IN MATS OR CAGES AND PLACED ON CHAIRS. 20. ALL WELDED WIRE MESH SHALL BE SMOOTH BARS CONFORMING TO ASTM A-185. -CONCRETE AND REINFORCEMENT - IBC 2015 CODE REFERENCED STANDARDS INCLUDE, BUT ARE NOT LIMITED TO: ASCE 7-10 -MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES AISC 360-10 -SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS ACI 318-14 -BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE ACI 301-13 -SPECIFICATIONS FOR STRUCTURAL CONCRETE AISI S100-12 -NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS 3/8" = 1'-0"S1.0 1 EXISTING ENTRANCE 3/8" = 1'-0"S1.0 2 PROPOSED ENTRANCE LINTEL AND FOUNDATION PLAN 3/4" = 1'-0"S1.0 3 TYPICAL FOUNDATION WALL 1 5 GREENLEAF WOODS DRIVE #302 PORTSMOUTH, NH 03801T. 603.319.1817 F. 877.808.1817WWW.SUMMITENGINEERINGINC.COM