Loading...
D4204 - S1 to S4 - 071620 - stamped1 OF 4 DRAWING NUMBER: DATE ISSUED: DRAWN BY: AS NOTED JOB NUMBER: SCALE: FILE NUMBER: CHECKED BY: DESIGNED BY: DWG. ISSUE LOGJOB TITLE:DRAWING TITLE:NUMBER DATE JOB LOCATION:COMMENTSSTAMP:SIGNATURE"INFORMATION ON THIS DRAWING IS ONLY INTENDED TO DEPICT THAT WHICH IS NECESSARY TO MEET THE STRUCTURAL REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ACCEPTED INDUSTRY STANDARDS. THE STRUCTURAL "PROFESSIONAL ENGINEER" STAMP AFFIXED TO THIS DOCUMENT SHALL NOT BE ASSUMED TO COVER REQUIREMENTS RELATED TO OTHER DESIGN DISCIPLINES SUCH AS ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, LIFE SAFETY, ETC."C DEI 2017Printed 7/16/2020 4:07 PM by Christopher GomezF:\PROJECTS\D4200 to D4299\D4204 - 25 Lynde St Salem MA - Reno and Addition\CAD - DEI\D4204-S.dwgVP D4204 VP/CRGCRG/VP 07-16-2020NEW ADDITION AND RENOVATIONSS-1Daigle Engineers, Inc.1 East River PlaceMethuen, MA01844-3818978 682 1748www.daigleengineers.comStructural EngineersFOUNDATION PLAN AND DETAILS25 LYNDE STREET - SALEM, MA.PERMIT O N L Y ISSUED F O R B U I L D I N G APPROX. SCALE: 1/4" = 1'-0" FOUNDATION PLAN10 EXIST. STONE FOUND. EXIST. STONE FOUND. EXIST. BRICK ARCH TO REMAIN EXIST. BRICK PIERS & CHIMNEY. SEE FIRST FLOOR FRAMING EXIST. STONE FOUND. NEW FULL HT. BASEMENT CONC. FOUND. NEW FULL HT. CONC. FOUND. WALLS. NEW CONC. FOUND. NEW CONC. FOUND. FROST WALL. SEE ARCH. DWGS FOR T.O.W. ELEVATIONS/ DROPS. SEE ARCH. DWGS FOR T.O.W. ELEVATIONS/ DROPS. SEE ARCH. DWGS FOR T.O.W. ELEVATIONS/ DROPS. 7"9'-1"29'-6"1'-0"32'-5 3/4" ± 1'-0" 1'-103 4" ± 7'-0"37'-4" ±9' - 9 1/2"6'-5" ±3'-8" 2'-0"15'-0 1/2"2'-0"13'-6 3/4" 1'-0" 1'-0" 1'-0" NEW 5" SLAB ON GRADE W/ FIBERMESH REINF. SLAB CONTROL JOINT - "C.J." TYP. C.J. C.J.C.J.C.J.C.J.NEW 4" SLAB ON GRADE W/ FIBERMESH REINF. PROVIDE CONTROL JOINTS @ 13 FT. MAX. EA. WAY ±. C.J. NEW CONT. CONC. FOOTING (FROST WALL - TYP. U.O.N.) NEW CONT. CONC. FOOTING - TYP. NEW CONT. CONC. FOOTING - TYP. CONC. PIER. CONC. PIER. FRONT3'-6"2'-0" 2'-0" FOOTING FLUSH W/ REAR WALL ONLY. 12 14 15 13 11 COORD. CONCRETE OPENINGS FOR OH AND MAN DOORS W/ FINAL ARCH. DWGS - TYP. STEP FTG DOWN AS REQ'D. SEE TYP. DETAIL "17/S-1". 1'-2" STEP FTG DOWN AS REQ'D. SEE TYP. DETAIL "17/S-1". NEW CONT. CONC. FOOTING (FROST WALL - TYP. U.O.N.) COORD. CONCRETE OPENINGS FOR OH AND MAN DOORS W/ FINAL ARCH. DWGS - TYP. 18 DOWEL NEW FOUND. TO EXIST. - TYP. SEE DETAIL "18/ S-1". NEW FULL HT. BASEMENT CONC. FOUND. 2'-4"2'-0" 2'-0" DOWEL NEW FOUND. TO EXIST. - TYP. SEE DETAIL "18/ S-1". 18 PROVIDE WALL INTERSECT BARS SIMILAR TO CORNER DETAIL. S-0 16 NOTE: FINAL FOUNDATION DESIGN TO BE ADJUSTED AFTER FULL BUILDING STRUCTURAL DESIGN COMPLETED. 2'-0" * STHD14 FOUNDATION HOLD-DOWNS EA. END OF OH. DOORS (TYP. - 4 TOTAL) * * * CONT. FTG 10" THICK x 20" WIDE. #4's @ 12" O.C. EA. WAY (3" BOT. COVER) 312" LALLY's w/ SPRINGFIELD PLATES (4 TOTAL) 10"x26" SQ. FTG's w/ #4's @ 12" O.C. EA. WAY (3" BOT. COVER) - TYP. 4 TOTAL. DOWEL FTG TO STONE FOUND. INACCESSIBLE OR S.O.G. @ FIRST FLOOR S-4 40 2'-0"2'-0"12"x4'-0" SQ. FTG w/ (4) #6's EA. WAY BOT. (IN ADDITION TO CONT. STRIP FTG)1'-0"WELL COMPACTED GRAVEL BACKFILL SEE PLAN FOR SLAB 12" PREMOULDED JOINT 2 - #4's HOR. CONT. TOP & BOTT. APPROX. SCALE: 1/2" = 1'-0" FOUND. FROST WALL SECTION124'-0" MIN.FIN. GRADE VARIES #4's VERT. @ 16" O.C. INSIDE FACE BACKFILL BOTH SIDES EVENLY 2x6 STUDS @ 16". (2) 2x6 SILL PL. P.T. ON CONC.5 8" Ø A307 ANCHOR BOLTS @ 48". 8" EMBED. + 3" HOOK. SIMPSON BPS 5 8-6 PLATE WASHERS.6" CONC. SHELF SEE ARCH. DWGS FOR TOP OF CONC. ELEVATIONS. WELL COMPACTED SUBGRADE. 10" 2'-0" MINIMUM1'-0"2-#4's CONTINUOUS 2 - #4's HOR. CONT. TOP, MIDDLE & BOTT. EQ.EQ. APPROX. SCALE: 1/2" = 1'-0" FOUND. BASEMENT SECTION11 FIN. GRADE VARIES #4's VERT. @ 16" O.C. EA. FACE 2x6 STUDS @ 16". (2) 2x6 SILL PL. P.T. ON CONC. 5 8" Ø A307 ANCHOR BOLTS @ 48". 8" EMBED. + 3" HOOK. SIMPSON BPS 5 8-6 PLATE WASHERS. SEE ARCH. DWGS FOR TOP OF CONC. ELEVATIONS. WELL COMPACTED SUBGRADE. 2x8 RIM JOIST FIN. FL. - SEE ARCH. #4 DOWELS @ 16" O.C. EA. FACE (38" x 14"). 2x8 JOISTS 10"2'-8" 3'-6" #5's VERT. @ 12" O.C. OUTSIDE FACE 5 - #4's HOR. (2) TOP & (3) BOTT. 12" PREMOULDED JOINT BASEMENT SLAB 10" 2'-0" MINIMUM1'-0"2-#4's CONTINUOUS WELL COMPACTED GRAVEL BACKFILL SEE PLAN FOR SLAB 12" PREMOULDED JOINT 2 - #4's HOR. CONT. TOP & BOTT. EQ.EQ. APPROX. SCALE: 1/2" = 1'-0" FOUND. FROST WALL SECTION134'-0" MIN.FIN. GRADE VARIES PROVIDE HOOKED ENDS AS SHOWN. #4's VERT. @ 16" O.C. EA. FACE BACKFILL BOTH SIDES EVENLY 2x6 STUDS @ 16". (2) 2x6 SILL PL. P.T. ON CONC.5 8" Ø A307 ANCHOR BOLTS @ 48". 8" EMBED. + 3" HOOK. SIMPSON BPS 5 8-6 PLATE WASHERS.6" SHELF SEE ARCH. DWGS FOR TOP OF CONC. ELEVATIONS. WELL COMPACTED SUBGRADE. 14 NOT TO SCALE SECTION AT DOOR OPENINGS 12"8"#4 DOWELS @ 16" O.C. (36" HORIZ. x 24" VERT.) SLAB. SEE PLAN FOR MORE INFO. WALL REINF. SEE DETAIL '13/S-1' FOR MORE INFO. NOTE: TYPICAL AT ALL DOORS U.O.N. CONT. 2x4 KEYWAY CONT. (1)#4 HORIZONTAL WALL REINF. #4 x 24" x 24" CORNER RODS (MATCH HORIZ. REINFORCING) 16 NOT TO SCALE CORNER REINFORCING DETAIL12"12" T/4 316"TSAW-CUT JOINTS AS SOON AS CONCRETE HAS HARDENED SUFFICIENTLY TO PREVENT AGGREGATE FROM BEING DISLODGED BY THE SAW. JOINTS MUST BE CUT BEFORE SHRINKING STRESSES BECOME SUFFICIENT TO PRODUCE CRACKING. 15 NOT TO SCALE SLAB CONTROL JOINT DETAIL SEE PLAN FOR LOCATIONS. OTHERWISE PROVIDE ROUGHLY AT 13 FT. EA. WAY. ALIGN WITH COLUMN CENTERLINES OR WALL JOGS IF POSSIBLE WHILE KEEPING PANELS RELATIVELY SQUARE. 1'-0" 1 3 1'-6" 2" 1 1 2'-0"MAX.FOOTING REINF. (SHOWN SOLID) WALL REINF. (SHOWN DASHED)48 Ø48 Ø TOP OF FOOTING SEE PLAN AND DETAILS FOR FOOTING SIZE AND REINF. MAXIMUM SLOPE OF STEPPED FTG. FOOTING 17 APPROX. SCALE: 1/2"=1'-0" STEPPED FOUND. DETAIL (TYPICAL WHERE NEW FOUNDATION WALLS ABUT EXISTING FOUNDATION WALLS U.O.N.) DRILL 7 8" DIA. HOLES INTO EXISTING STONE FOUND. (FULL HT. OF WALL) AND EPOXY REBARS SOLIDLY IN PLACE USING HILTI HIT-HY 270 EPOXY. #4 REBARS (CENTERED) NEWEXISTING 16"TYP.2'-0" 8" 30° NOT TO SCALE FOUND. DOWEL DETAIL18 2 OF 4 DRAWING NUMBER: DATE ISSUED: DRAWN BY: AS NOTED JOB NUMBER: SCALE: FILE NUMBER: CHECKED BY: DESIGNED BY: DWG. ISSUE LOGJOB TITLE:DRAWING TITLE:NUMBER DATE JOB LOCATION:COMMENTSSTAMP:SIGNATURE"INFORMATION ON THIS DRAWING IS ONLY INTENDED TO DEPICT THAT WHICH IS NECESSARY TO MEET THE STRUCTURAL REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ACCEPTED INDUSTRY STANDARDS. THE STRUCTURAL "PROFESSIONAL ENGINEER" STAMP AFFIXED TO THIS DOCUMENT SHALL NOT BE ASSUMED TO COVER REQUIREMENTS RELATED TO OTHER DESIGN DISCIPLINES SUCH AS ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, LIFE SAFETY, ETC."C DEI 2017Printed 7/16/2020 4:26 PM by Vincent PulselliF:\PROJECTS\D4200 to D4299\D4204 - 25 Lynde St Salem MA - Reno and Addition\CAD - DEI\D4204-S.dwgVP D4204 VP/CRGCRG/VP 07-16-2020NEW ADDITION AND RENOVATIONSS-2Daigle Engineers, Inc.1 East River PlaceMethuen, MA01844-3818978 682 1748www.daigleengineers.comStructural EngineersFIRST AND SECOND FLOOR FRAMINGPLANS25 LYNDE STREET - SALEM, MA.PERMIT O N L Y ISSUED F O R B U I L D I N G FRONT APPROX. SCALE: 1/4" = 1'-0" FIRST FLOOR FRAMING PLAN20 2x8 JOISTS @ 16" O.C. OR SLAB ON GRADE SEE FOUNDATION PLAN 2x8 JOISTS @ 16" O.C.EXIST. JOISTS (6"Wx5"D @ 2'-3"± O.C.) SUPPLEMENT MEMBERS AS REQ'D (2) 13 4"x512" VL STAIR OPENING HHUS46 HANGER ML24Z EA. SIDE EXIST. PIER(3) 134"x512" VLEXIST. 9"x712"D SUPPLEMENT CONN.'s w/ ML23Z EA. SIDE (TYP. U.ON.) LUS28-3 EA. END ALIGN LALLY's w/ POSTS ABOVE NEW 312"LALLYEXIST. LALLY TO BE REPLACED EXIST ARCH TO REMAIN EXIST. BUILT-UP TIMBER BEAM TO REMAIN EXIST. CHIMNEY TO BE REMOVED (ASSUMED NON STRUCTURAL) EXIST. LALLY's TO BE REMOVED EXIST. UPPER 9"x712"W BEAM TO REMAIN. SISTER w/ (1) 13 4"x914" VL EA. SIDE. REMOVE LOWER 6x8 BEAM. (3) 2x8's DBL 2x8 RIM JOIST SISTER EXIST. 9x9 w/ (1) 13 4"x914" VL EA. SIDE MAJOR POSTS ABOVE BEARING ON SILL. CONFIRM (TYP.)2x8 JOISTS @ 12" O.C.* * * * FOUNDATION HOLD DOWNS. SEE FOUND. PLAN (TYP.) EXIST. STONE FOUND. PIERS TO BE REMOVED IF HEARTH IS TO BE REMOVED(3) 2x8NEW FOUND. BEAR VL's ON BEAM (2) L4x4x516" CLIP ANGLES x 8" LONG. FASTEN EA. LEG w/ (2) 7 8" DIA. A307 THRU BOLTS (6 TOTAL) EXIST. SILL BEAM SUPPLEMENT AS REQ'D NEW FOUNDATIONS LUS28 HANGERS INTO EXIST. SILL BEAM (TYP.) PROVIDE FJA FOUND. ANCHORS @ 4'-0"± (TYP. @ EXIST. STONE FOUNDATIONS) PROVIDE DBL 2x BLOCKING FOR FOUND. ANCHORS w/ ML CLIPS (TYP. WHERE JOISTS ARE PARALLEL w/ FOUND.) FRONT APPROX. SCALE: 1/4" = 1'-0" SECOND FLOOR FRAMING PLAN21912" BCI 6000s 1.8 JOISTS @ 16" O.C. (TYP. U.O.N.)912" BCI 6000s 1.8 JOISTS @ 16" O.C. (TYP. U.O.N.)P O S T U P SISTER EXIST. JOISTS w/ 2x8's (TYP.)2x8 JOISTS @ 16" O.C. (TYP. U.O.N.)STAIR OPENING REPLACE BEAM w/ W8x15 STEEL BEAM REPLACE BEAM w/ W8x28 STEEL BEAM REPLACE BEAM w/ W8x28 STEEL BEAM (2) 2x8W8x152x8 JOISTS @ 12" O.C. (TYP. U.O.N.)514"x714" VL POST. PROVIDE CUSTOM STEEL SADDLE CONNECTION TO ATTACH BEAM TO POST (SAME OPPOSITE END). ** MSTI36 STRAP BEAM TO POST EACH SIDE EACH END @ O.H. DOORS (TYP. - 8 TOTAL). PAD OUT BEAM FOR STRAPS **W14x22 (LOW) + 2x6 TOP SPIKER31 2"x 5 1 2" VL P O S T 31 2"x 5 1 2" VL P O S T 912" BCI 6000s 1.8 JOISTS @ 12" O.C. WHERE CLEAR SPAN IS GREATER THAN 16'-8" ** ** 31 2"x 5 1 2" VL P O S T 31 2"x 5 1 2" VL P O S T (3) 134"x20" VL FLUSH(3) 2x8DBL JACKS (TYP. U.O.N.) 51 4"x 7 1 4" VL P O S T (3) 2x8(2) 2x8 (2) 2x8 312"x512" VL POST. ALIGN w/ POST ABOVE 312"x512" VL POST. ALIGN w/ POST ABOVE ML24Z CLIP EA. SIDE (TYP.) STD. DBL WELDED CLIP ANGLE CONN. @ STEEL TO STEEL CONN.'s. USE L3x3x516" STEEL ANGLES x 5" LONG EXIST. 6x8 WALL HEADERS ASSUMED 4x6 SPF POST (TYP. @ STEEL BEAMS U.O.N.) 312"x512" VL POST. ALIGN w/ POST ABOVE 312"x512" VL POST. ALIGN w/ POST ABOVE (3) 2x8 HEADER (TYP. U.O.N.) FLUSH FRAME AS REQ'D.W21x57IUS2.37/9.5 HANGERS (TYP. @ BCI's) 2x8's @ 16" O.C. S-4 41 SIM. S-4 41 FINAL SHEAR WALL DESIGN PENDING. 3 OF 4 DRAWING NUMBER: DATE ISSUED: DRAWN BY: AS NOTED JOB NUMBER: SCALE: FILE NUMBER: CHECKED BY: DESIGNED BY: DWG. ISSUE LOGJOB TITLE:DRAWING TITLE:NUMBER DATE JOB LOCATION:COMMENTSSTAMP:SIGNATURE"INFORMATION ON THIS DRAWING IS ONLY INTENDED TO DEPICT THAT WHICH IS NECESSARY TO MEET THE STRUCTURAL REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ACCEPTED INDUSTRY STANDARDS. THE STRUCTURAL "PROFESSIONAL ENGINEER" STAMP AFFIXED TO THIS DOCUMENT SHALL NOT BE ASSUMED TO COVER REQUIREMENTS RELATED TO OTHER DESIGN DISCIPLINES SUCH AS ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, LIFE SAFETY, ETC."C DEI 2017Printed 7/16/2020 4:09 PM by Christopher GomezF:\PROJECTS\D4200 to D4299\D4204 - 25 Lynde St Salem MA - Reno and Addition\CAD - DEI\D4204-S.dwgVP D4204 VP/CRGCRG/VP 07-16-2020NEW ADDITION AND RENOVATIONSS-3Daigle Engineers, Inc.1 East River PlaceMethuen, MA01844-3818978 682 1748www.daigleengineers.comStructural EngineersTHIRD FLOOR AND ROOF FRAMING PLANS25 LYNDE STREET - SALEM, MA.PERMIT O N L Y ISSUED F O R B U I L D I N G APPROX. SCALE: 1/4" = 1'-0" THIRD FLOOR FRAMING PLAN30 FRONT912" BCI 6000s 1.8 JOISTS @ 16" O.C. (TYP. U.O.N.)912" BCI 6000s 1.8 JOISTS @ 16" O.C. (TYP. U.O.N.)2x8 JOISTS @ 16" O.C. (TYP. U.O.N.)C A R R Y P O S T D O W N P O S T U P P O S T U P P O S T U P W10x30 W10x30 BEARING WALL ABOVE DBL 2x8's @ 16" O.C. THIS BAY ONLY 2X8'S @ 16" O.C. (TYP. U.O.N.) 2X8'S @ 16" O.C. SIMPSON LUS28 HANGERS (LUS28-2 @ DBL's) TYP. BEARING WALL ABOVE(2) 13 4"x714" VL BEARING WALL ABOVE (2) 13 4"x714" LVL P O S T U P P O S T U P (2) 13 4"x912" VL STEP FULL BEARING 2x BUILT UP POSTS (TYP. U.O.N.) (3) 13 4"x912" VL(3) 13 4"x912" VL (3) 13 4"x912" VL (3) 13 4"x912" VL 912" BCI 6000s 1.8 JOISTS @ 12" O.C. (3) 13 4"x714" VL (LOW)(2) 134"x912" VL(3) 2x POST STAIR OPENING (2) 2x8(2) 2x8(2) 134"x 714" VLSTAIR OPENING (2) 13 4"x714" VL HEADER 514"x512" VL POST 514"x512" VL POST (2) 2x8 (3) 2x8 (3) 134"x 714" VL(3) 134"x 714" VLHGUS5.50/8 HANGER (3) 2x8 WINDOW HEADER (TYP. @ NEW WALLS U.O.N.)(2) 134"x 714" VL(2) 134"x 714" VL(2) 134"x 714" VL31 2" L A L L Y w / S F P L . (3 ) 2 x 4 P O S T(2) 2x8BEARING WALL ABOVE (2) 2x8 WINDOW HEADER (TYP. @ EXIST. 2x4 WALLS U.O.N.) HANGER SCHEDULE (TYP. U.O.N.) 2x8 - LUS28 (2) 2x8 -LUS28-2 (3) 2x8 - LUS28-3 (2) 13 4"x714" VL - HHUS48 (3) 13 4"x714" VL - HU68 STAIR OPENING STAIR OPENING IUS2.37/9.5 HANGERS (TYP. @ BCI's)(3) 134"x 714" VL3 1 2 "x5 1 2 "VL P O ST (3) 134"x714" VLS-4 41 SIM. S-4 41 SIM. FINAL SHEAR WALL DESIGN PENDING BEARING WALL TIGHT TO RIDGE APPROX. SCALE: 1/4" = 1'-0" ROOF FRAMING PLAN31 FRONT 13 4"x1114" LVL HIP BEAMS 2x10 RAFTERS @ 16" O.C. (TYP. U.O.N.)2x10 RAFTERS @ 12" O.C. (TYP. U.O.N.)2x10 RAFTERS @ 16" O.C.OVERFRAME 2x10's RAFTERS @ 16" O.C. (TYP.) 2x8 RAFTERS @ 16" O.C. (TYP.) (2) 2x6 POST DOWN SIMPSON LS70 CLIPS (TYP.)2x12 RIDGE BOARDSIMPSON LTS12 STRAPS (TYP.) DBL 2x10 (TYP.) PROVIDE SIMPSON H2.5A HURRICANE TIES (TYP.) SEE "43/S-4" (1) 2x10 (TYP.) (3) 2x4 WINDOW HEADER (TYP) (3) 2x8 HEADERS BELOW (TYP.) TRPL 2x10 SIMPSON LUS28 HANGERS (LUS28-2 @ DBL's) TYP. DBL 2x10 STUDS FULL HEIGHT @ GABLES (3) 2x6 POST (3) 2x4 POST (2) 13 4"x117 8" LVL RIDGE BEAM (1) 13 4"x117 8" LVL RIDGE BEAM 2x8 RAFTERS @ 16" O.C. (2) 2x8 (2) 2x8(2) 2x8 (2) 2x POST @ RIDGES U.O.N. 4 OF 4 DRAWING NUMBER: DATE ISSUED: DRAWN BY: AS NOTED JOB NUMBER: SCALE: FILE NUMBER: CHECKED BY: DESIGNED BY: DWG. ISSUE LOGJOB TITLE:DRAWING TITLE:NUMBER DATE JOB LOCATION:COMMENTSSTAMP:SIGNATURE"INFORMATION ON THIS DRAWING IS ONLY INTENDED TO DEPICT THAT WHICH IS NECESSARY TO MEET THE STRUCTURAL REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ACCEPTED INDUSTRY STANDARDS. THE STRUCTURAL "PROFESSIONAL ENGINEER" STAMP AFFIXED TO THIS DOCUMENT SHALL NOT BE ASSUMED TO COVER REQUIREMENTS RELATED TO OTHER DESIGN DISCIPLINES SUCH AS ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, LIFE SAFETY, ETC."C DEI 2017Printed 7/16/2020 4:10 PM by Christopher GomezF:\PROJECTS\D4200 to D4299\D4204 - 25 Lynde St Salem MA - Reno and Addition\CAD - DEI\D4204-S.dwgVP D4204 VP/CRGCRG/VP 07-16-2020NEW ADDITION AND RENOVATIONSS-4Daigle Engineers, Inc.1 East River PlaceMethuen, MA01844-3818978 682 1748www.daigleengineers.comStructural EngineersDETAILS AND GENERAL NOTES25 LYNDE STREET - SALEM, MA.PERMIT O N L Y ISSUED F O R B U I L D I N G (2) 12" DIA. HILTI HY-270 EPOXY ANCHORS (8" EMBED.) 1. FOUNDATIONS: A)ALL FOOTINGS SHALL BEAR ON UNDISTURBED VIRGIN SOIL HAVING A MINIMUM SOIL BEARING CAPACITY OF 3,000 PSF (POUNDS PER SQUARE FOOT). BEARING CAPACITY IS PRESUMED. NOTIFY ENGINEER IF POOR SOIL, FILL MATERIAL, CLAYS, SILTS, WATER TABLE, ETC. IS ENCOUNTERED. B)THE BOTTOM ELEVATION OF EXTERIOR FOOTINGS SHALL BE A MINIMUM OF 4'-0" BELOW OUTSIDE GRADE. LOWER FOOTINGS AS REQUIRED TO REACH SOIL PROVIDING THE REQUIRED BEARING CAPACITY. C)ALL FOOTING EXCAVATIONS SHALL BE FINISHED BY HAND AND SHALL BE THOROUGHLY COMPACTED PRIOR TO FORMING FOOTINGS. ALL FINISHED FOUNDATION EXCAVATIONS SHALL BE INSPECTED AND APPROVED BY THE OWNER'S QUALIFIED REPRESENTATIVE OR BUILDING OFFICIAL PRIOR TO CONCRETE PLACEMENT. D)ALL CONCRETE SHALL BE PLACED IN DRY EXCAVATIONS. PUMP AWAY GROUND WATER AS REQUIRED. E)UNLESS OTHERWISE NOTED ON THE STRUCTURAL DRAWINGS ALL FOUNDATION SPREAD AND CONTINUOUS FOOTINGS SHALL BE CENTERED UNDER THE COLUMN ABOVE. F)FOUNDATION WALLS SHALL BE BACKFILLED EVENLY ON BOTH SIDES WHERE POSSIBLE. 2. CONCRETE: A)ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS UNLESS OTHERWISE SPECIFIED HEREIN, OR NOTED ON THE DRAWINGS, OR REQUIRED BY CODE. SLABS SHALL BE FIBERMESH REINFORCED CONCRETE. B)MAXIMUM ALLOWABLE SLUMP OF CONCRETE SHALL NOT EXCEED 4". C)ALL CONCRETE EXPOSED TO WEATHER OR POSSIBLE FREEZE/THAW CYCLES SHALL CONTAIN AN AIR ENTRAINMENT ADMIXTURE AS REQUIRED TO PROVIDE A TOTAL AIR CONTENT OF 6% +/-1.5% UNLESS OTHERWISE SPECIFIED OR NOTED ON THE DRAWINGS. D)ALL CONCRETE SLABS SHALL BE CURED ACCORDING TO ACI SPECIFICATIONS. SLABS SHALL BE REINFORCED WITH FIBERMESH OR APPROVED EQUAL. PROVIDE PER MANUFACTURER'S GUIDELINES AND SPECIFICATIONS. E)ALL CONCRETE WORK SHALL COMPLY WITH THE LATEST EDITION OF THE ACI "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318)" AND THE LATEST MASSACHUSETTS STATE BUILDING CODE. IN CASES OF CONFLICT, THE REQUIREMENTS OF THE MORE STRINGENT CODE SHALL GOVERN. F)ALL CONCRETE SHALL BE PLACED UNDER THE SUPERVISION OF THE OWNERS' QUALIFIED REPRESENTATIVE OR BUILDING OFFICIAL. G)ALL KEYS SHALL BE A MINIMUM OF 2 BY 4 INCHES (NOMINAL) UNLESS OTHERWISE NOTED ON THE DRAWINGS. H)NO CONCRETE SHALL BE PLACED UNTIL THE REINFORCEMENT STEEL AND/OR EMBEDDED ITEMS HAVE BEEN REVIEWED AND APPROVED BY THE OWNER'S REPRESENTATIVE OR BUILDING OFFICIAL. I)REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZES OF ALL DOOR AND WINDOW OPENINGS, REGLETS, WASHES, SLOPES, CONCRETE FINISHES, MASONRY ANCHORS, MISCELLANEOUS EMBEDDED ITEMS AND ALL OTHER ITEMS THAT MUST BE OTHERWISE INCORPORATED INTO THE CONCRETE WORK. J)THE PLACEMENT OF SLEEVES, OUTLET BOXES, CONDUIT, BOX-OUTS, ANCHORS, ETC. FOR THE MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SYSTEMS ARE THE RESPONSIBILITY OF THE TRADE INVOLVED. HOWEVER, ANY BOX-OUTS, OR OTHER OPENINGS IN THE CONCRETE, NOT INDICATED ON THE STRUCTURAL DRAWINGS, SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION IN THE FORMWORK. K)THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING AND COORDINATING ALL ELEVATIONS RELATED TO THE CONCRETE WORK WITH THE ARCHITECTURAL DRAWINGS OR SITE CONDITIONS. L)GROUT UNDER ALL COLUMN BASE PLATES AND ALL OTHER SETTING AND BEARING PLATES SHALL BE NON-METALLIC, NON-SHRINK GROUT WITH A MINIMUM COMPRESSIVE STRENGTH OF 5,000 PSI AT 3-DAYS. 3. REINFORCING STEEL: A)ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 60, AND SHALL BE COLD BENT. B)DETAILING AND FABRICATION OF CONCRETE REINFORCEMENT AND RELATED ACCESSORIES SHALL BE IN ACCORDANCE WITH LATEST EDITION OF "ACI 315 - DETAILS AND DETAILING OF CONCRETE REINFORCEMENT". C)WELDED WIRE FABRIC (W.W.F.), IF APPROVED IN PLACE OF FIBER MESH REINFORCING IN SLABS, SHALL BE ASTM A-185 (Fy = 65 ksi MINIMUM). LAP ALL SPLICES 12" MINIMUM AND SECURELY FASTEN W.W.F. IN PLACE TO PREVENT MOVEMENT DURING CONCRETE PLACEMENT. ALL W.W.F. SHALL BE FURNISHED IN FLAT SHEETS ONLY AND SHALL BE SUPPORTED ON APPROVED SLAB BOLSTERS ONLY. PROVIDE PROPER COVER. DO NOT USE W.W.F. WITHOUT APPROVAL FROM ARCHITECT AND ENGINEER. D)ALL HORIZONTAL RODS ARE CONTINUOUS. THE LENGTH OF ALL LAP SPLICES SHALL BE 2'-0". PROVIDE WALL CORNER AND INTERSECTING BARS PER INDUSTRY STANDARDS. E)PROVIDE A CLEAR COVER FROM REINFORCING STEEL TO ADJACENT CONCRETE SURFACES AS FOLLOWS: SURFACES CAST AGAINST EARTH: 3" BOTTOM OF FOOTINGS: 3" PIERS AND WALLS: 1½" at #5 and smaller 2" at #6 and larger FORMED SURFACES NOT EXPOSED TO EARTH OR WEATHER: WALLS ¾" SLABS ON GRADE 112" below top of slab THESE DIMENSIONS SHALL BE CONSIDERED ACTUAL AND ARE NOT TO BE ADJUSTED IN EITHER DIRECTION UNLESS OTHERWISE DETAILED ON THE STRUCTURAL DRAWINGS. F)SUBMIT REINFORCING STEEL SHOP DRAWINGS FOR REVIEW BY THE ENGINEER. G)ALL REINFORCING RODS AND W.W.F. SHALL BE SECURED IN PROPER POSITION ON CHAIRS, STANDEES, BOLSTERS, ETC. AS MANUFACTURED BY RICHMOND SCREW ANCHOR CO. OR APPROVED EQUAL. LINES OF CHAIRS, HIGH-CHAIRS AND BOLSTERS SHALL BE SPACED AT MAXIMUM 4'-0" O.C. H)PROVIDE ADDITIONAL REINFORCEMENT AT SIDES AND CORNERS OF ALL OPENINGS IN SLABS AND WALLS AS DETAILED ON THE STRUCTURAL DRAWINGS AND PER INDUSTRY STANDARDS. PROVIDE MINIMUM LAP LENGTHS EACH SIDE OF OPENING AND PROVIDE STANDARD HOOKED ENDS WHERE REQUIRED LAP IS NOT POSSIBLE. I)THE FOUNDATION CONTRACTOR/ SUBCONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR FULL COMPLIANCE WITH ALL FEDERAL OSHA SAFETY REGULATIONS AND REQUIREMENTS RELATED TO THE WORK PERFORMED BY THEM ON THIS PROJECT. J)ALL DOWELS FROM FOOTINGS INTO PIERS, COLUMNS, PILASTERS, BUTTRESSES OR WALLS ABOVE SHALL BE THE SAME SIZE AND NUMBER AS THE VERTICAL REINFORCEMENT IN THE PIER, COLUMN, PILASTER AND WALLS ABOVE EXCEPT WHERE NOTED OTHERWISE ON THE DRAWINGS. ALL DOWELS SHALL HAVE 90 DEGREE STANDARD HOOKED ENDS IN THE FOOTING UNLESS OTHERWISE NOTED ON THE DRAWINGS. 4. STRUCTURAL STEEL: A)ALL STRUCTURAL STEEL ROLLED SHAPES SHALL CONFORM TO THE FOLLOWING: ASTM A992 (F/y = 50 ksi):WIDE FLANGE SHAPES ASTM A36 (F/y = 36 ksi):ALL OTHER STRUCTURAL STEEL SHAPES B)ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST A.I.S.C. SPECIFICATIONS. SUBMIT SHOP DRAWINGS FOR REVIEW BY THE STRUCTURAL ENGINEER. DO NOT REPRODUCE STRUCTURAL DRAWINGS FOR SHOP DRAWING PURPOSES. C)SHOP AND FIELD CONNECTIONS, UNLESS OTHERWISE NOTED, SHALL BE MADE BY WELDING OR HIGH-STRENGTH BOLTING. BOLTED CONNECTIONS SHALL CONFORM TO ASTM A325. BOLTS SHALL BE HOT DIP GALVANIZED IF EXTERIOR. D)ALL WELDED CONNECTIONS SHALL BE MADE USING E70XX ELECTRODES. WELDING SHALL COMPLY WITH A.I.S.C. AND A.W.S. SPECIFICATIONS AND SHALL BE PERFORMED BY A.W.S. CERTIFIED WELDERS. WELD SIZES NOT INDICATED ON THE DRAWINGS SHALL BE MINIMUM WELD SIZES, AS REQUIRED BY THE A.I.S.C., BASED ON THE THICKNESS OF THE THICKER MEMBER IN THE CONNECTION. E)SPLICING OF STRUCTURAL MEMBERS IS NOT ACCEPTABLE, EXCEPT WHERE DETAILED ON THE STRUCTURAL DRAWINGS, WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. WHERE SPLICES ARE SHOWN, OR APPROVED, THE SPLICE CONNECTION SHALL DEVELOP THE FULL YIELD STRENGTH OF THE MEMBERS BEING CONNECTED UNLESS DETAILED OTHERWISE. F)NO HOLES SHALL BE BURNED OR CUT IN STRUCTURAL STEEL MEMBERS IN THE FIELD WITHOUT CONSENT OF THE STRUCTURAL ENGINEER FOR EACH HOLE/CUT IN EACH MEMBER. HOLES AND OPENINGS IN STRUCTURAL MEMBERS FOR WORK OF OTHER TRADES SHALL BE PERFORMED IN THE SHOP WHEREVER POSSIBLE. G)THE GENERAL CONTRACTOR AND HIS SUBCONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF RECORD (S.E.R.) OF ANY AND ALL DEVIATIONS FROM APPROVED SHOP DRAWINGS PRIOR TO FABRICATION/ ERECTION. H)ALL STRUCTURAL STEEL SHALL BE SHOP PRIMED WITH A RUST-INHIBITIVE PRIMER. TOUCH-UP ALL SCRATCHES, WELD BURNS, AND OTHER MARKS IN THE FIELD AFTER STEEL IS ERECTED. 5. TIMBER: A)ALL LUMBER USED SHALL BE S-P-F (SPRUCE-PINE-FIR) NO. 2 OR BETTER (EXCEPT FOR PRESSURE TREATED LUMBER), AND SHALL BEAR THE STAMP OF THE APPROVING GRADING AGENCY. ALL FRAMING LUMBER USED ON THE PROJECT SHALL BE KILN DRIED LUMBER AND SHALL BE STORED OFF THE GROUND AND COVERED WITH WATERPROOF SHEETING TO PROTECT IT FROM WEATHER. B)ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESERVATIVE TREATED LUMBER. PRESERVATIVE TREATED LUMBER SHALL BE SOUTHERN YELLOW PINE NO. 2 OR BETTER. C)FASTEN LUMBER SECURELY TOGETHER AND TO ALL SUPPORTS AS DETAILED ON THE DRAWINGS AND PER INDUSTRY STANDARDS. D)ALL PLYWOOD SHALL BE APA CD EXTERIOR GRADE UNLESS OTHERWISE NOTED. SEE ARCHITECTURAL DRAWINGS FOR THICKNESSES. E)ALL TIMBER FRAMING SHALL COMPLY WITH THE NDS (NATIONAL DESIGN SPECIFICATION) AND ALL APPLICABLE BUILDING CODES. F)THE GENERAL CONTRACTOR AND THIS SUBCONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF RECORD (S.E.R.) OF ANY AND ALL CHANGES TO TIMBER COMPONENTS AND MATERIAL SUBSTITUTIONS FROM THOSE ON THE APPROVED SHOP DRAWINGS OR STRUCTURL DRAWINGS SO THE S.E.R. CAN REVIEW THE MODIFICATIONS PRIOR TO INSTALLATION. G)ALL JOIST HANGERS AND OTHER METAL ACCESSORIES USED FOR ATTACHING STRUCTURAL COMPONENTS TOGETHER SHALL BE AS MANUFACTURED BY "SIMPSON/STRONG TIE COMPANY". IF THE TYPE OR SIZE OF HANGER IS NOT SPECIFIED ON THE DRAWINGS, HARDWARE CONSISTENT WITH INDUSTRY STANDARDS SHALL BE USED PENDING VERIFICATION OF ADEQUACY WITH THE ENGINEER. HARDWARE SHALL BE INSTALLED USING THE NUMBER AND TYPE OF FASTENERS SPECIFIED BY THE MANUFACTURER FOR THAT SPECIFIC CONNECTION. SUBSTITUTIONS FOR PRODUCTS EQUAL TO THOSE MANUFACTURED BY SIMPSON SHALL BE SUBMITTED WITH FULL CATALOG DOCUMENTATION OF CONFIGURATIONS AND LOAD RATINGS. REFER TO FOLLOWING FOR REQUIREMENTS WHEN ATTACHING TO PRESSURE TREATED LUMBER. H)ALL METAL PLATE FRAMING CONNECTORS (i.e. TIE STRAPS, JOIST HANGERS, HOLDOWNS, HURRICANE CLIPS, POST CAPS, POST BASES, ETC.) IN DIRECT CONTACT WITH CROMATED COPPER ARSENATE (CCA-C), SODIUM BORATE (SBX), ALKALINE COPPER QUAT (ACQ-C & ACQ-D), COPPER AZOLE (CBA-A & CA-B) OR SBX w/ NaSiO2 PRESERVATIVE TREATED LUMBER SHALL HAVE HOT DIPPED GALVANIZED (G135 HDG PER ASTM A653) FINISH SUCH AS "ZMAX" FINISH BY SIMPSON STRONG-TIE, OR APPROVED EQUAL. ALL FRAMING CONNECTORS IN CONTACT WITH ANY OTHER TYPE OF PRESERVATIVE TREATMENT SHALL BE FABRICATED FROM TYPE 306 AND TYPE 316 STAINLESS STEEL. THE FASTENERS USED TO SECURE THESE CONNECTORS SHALL BE OF THE SAME FINISH AS THE CONNECTORS. SOME STAINLESS STEEL "SIMPSON" CONNECTORS MAY REQUIRE TO BE SPECIAL ORDERED. NOTIFY ENGINEER OF ANY SUBSTITUTES IF STAINLESS STEEL CANNOT BE ORDERED. I)ALL FASTENERS (i.e. CARRAIGE BOLTS, ANCHOR RODS, LAG BOLTS, NAILS, SCREWS, ETC.) IN DIRECT CONTACT WITH CROMATED COPPER ARSENATE (CCA-C), SODIUM BORATE (SBX), ALKALINE COPPER QUAT (ACQ-C & ACQ-D), COPPER AZOLE (CBA-A & CA-B) OR SBX w/ NaSiO2 PRESERVATIVE TREATMENTED WOOD SHALL HAVE HOT DIPPED GALVANIZED (G135 HDG PER ASTM A653) FINISH, OR APPROVED EQUAL. ALL FASTENERS IN CONTACT WITH ANY OTHER TYPE OF PRESERVATIVE TREATED WOOD SHALL BE FABRICATED FROM TYPE 306 AND TYPE 316 STAINLESS STEEL. 6.BCI “I-JOIST” MEMBERS (IF SPECIFIED): A)ALL BCI LUMBER SHALL BE MANUFACTURED BY BOISE CASCADE OR APPROVED EQUAL. SUBSTITUTIONS WILL ONLY BE REVIEWED FOR USE IF ALL SUBSTITUTIONS ARE CLEARLY NOTED ON SHOP DRAWINGS AND ALL PERTINENT LOAD CAPACITY INFORMATION IS SUBMITTED. B)THE CONTRACTOR MUST HAVE A COPY OF THE "BUILDER'S GUIDE TO THE FRAMEWORKS BUILDING SYSTEM" ON THE JOB AT ALL TIMES WHILE THE FRAMING IS BEING CONSTRUCTED. C)THE GENERAL NOTES LISTED IN THE "BUILDER'S GUIDE TO THE FRAMEWORKS BUILDING SYSTEM" REFERENCED IN ITEM 6B ABOVE IS HEREBY INCORPORATED IN THIS PROJECT ALONG WITH ALL ASSOCIATED DETAILS, RECOMMENDATIONS AND NOTES. D)PROVIDE SQUASH BLOCKS, WEB STIFFENERS ETC. AS REQUIRED BY BOISE CASCADE AND THE STRUCTURAL DRAWINGS. E)CORING OF HOLES THROUGH BCI's SHALL CONFORM WITH THE REQUIREMENTS SET FORTH BY THE MANUFACTURER'S DESIGN BROCHURE. F)BCI JOISTS NOT DESIGNED TO SUPPORT NATURAL STONE FLOORING. CONSULT WITH ENGINEER. 7. LAMINATED VENEER LUMBER (NOTED AS "LVL" OR “VL” ON DRAWINGS): A)ALL LAMINATED VENEER LUMBER SHALL BE BY BOISE CASCADE OR APPROVED EQUAL. B)ALL LAMINATED VENEER LUMBER SHALL HAVE THE FOLLOWING MINIMUM ALLOWABLE DESIGN PROPERTIES: Fb = 3,100 PSI Fv = 285 PSI E = 2,000,000 PSI C)FASTEN MULTIPLE MEMBER LAMINATED VENEER BEAMS ACCORDING TO MANUFACTURER'S SPECIFICATIONS UNLESS OTHERWISE NOTED OR DETAILED ON THE STRUCTURAL DRAWINGS. D)THE GENERAL CONTRACTOR AND/OR SUBCONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF RECORD (S.E.R.) OF ANY AND ALL CUTS, CORED HOLES AND NOTCHES OTHER THAN THOSE INDICATED ON THE DRAWINGS SO THE S.E.R. CAN REVIEW THE MODIFICATIONS PRIOR TO INSTALLATION. 8. EPOXY ANCHORS: A)ANCHORS WHICH ARE TO BE EPOXIED INTO CONCRETE OR MASONRY ARE TO BE DONE SO USING "HILTI" FASTENERS. UNLESS SPECIFIED ELSEWHERE ON THE DRAWINGS, ANCHORS SHALL BE OF THE FOLLOWING TYPE BASED ON THE MATERIAL IN WHICH THEY ARE TO BE EMBEDDED: CONCRETE -"HIT-HY 200"; OR, "HIT-ICE" (FOR WINTER CONDITIONS) BRICK, STONE OR CONCRETE BLOCK -"HIT-HY 270" ALTERNATE MATERIALS MAY BE USED; HOWEVER, ANY SUBSTITUTION MUST BE APPROVED BY THE ENGINEER PRIOR TO ITS USE. B)HOLES TO BE DRILLED FOR THE ANCHORS SHALL BE OF THE DIAMETER SPECIFIED BY THE MANUFACTURER FOR THAT SPECIFIC ANCHOR, AND THE EMBEDMENT DEPTH SHALL BE AS NOTED ON THESE DRAWINGS. IF EMBEDMENT IS NOT NOTED, THE MAXIMUM DEPTH SPECIFIED BY THE MANUFACTURER FOR THAT ANCHOR DIAMETER SHALL BE USED. NOTIFY ENGINEER OF MISSING EMBEDMENT INFORMATION PRIOR TO IMPLEMENTATION. C)HOLES SHALL BE CLEANED THOROUGHLY BEFORE PROCEEDING WITH THE ANCHOR EMBEDMENT. AT A MINIMUM, THE FOLLOWING HOLE PREPARATION AND CLEANING SHALL BE FOLLOWED AT ALL HOLES DRILLED FOR EPOXY ANCHORS: "STEP 1" - REMOVE ALL DUST AND DEBRIS FROM HOLE WITH COMPRESSED OR VACUUM WITH A NOZZLE INSERTED TO THE BOTTOM OF HOLE; "STEP 2" - WIRE BRUSH ALL PERIMETER SURFACES OF INSIDE OF HOLE WITH BRUSH EQUAL TO HOLE DIAMTER; "STEP 3" - REPEAT HOLE CLEANING OUTLINED IN "STEP 1" ABOVE. THESE PREPARATION AND CLEANING REQUIREMENTS ARE A MINIMUM, IF BOLT MANUFACTURER'S REQUIREMENTS ARE MORE STRINGENT THEY SHALL BE FOLLOWED. D)ANCHORS INTO MASONRY SHALL HAVE A SCREEN INSERT AS SPECIFIED BY THE ANCHOR MANUFACTURER. E)ALL INSTALLATION REQUIREMENTS SPECIFIED BY THE MANUFACTURER MUST BE STRICTLY FOLLOWED. 9. EXPANSION BOLTS: A)EXPANSION BOLTS SHALL BE "HILTI- KWIK BOLT TZ" FASTENERS UNLESS OTHERWISE NOTED ON THE DRAWINGS. SIZE OF ANCHORS SHALL BE AS SPECIFIED ON THE DRAWINGS. B)HOLES TO BE DRILLED FOR THE ANCHORS SHALL BE OF THE DIAMETER SPECIFIED BY THE MANUFACTURER FOR THAT SPECIFIC ANCHOR, AND THE EMBEDMENT DEPTH SHALL BE AS NOTED ON THESE DRAWINGS. IF EMBEDMENT IS NOT NOTED, THE MAXIMUM DEPTH SPECIFIED BY THE MANUFACTURER FOR THAT ANCHOR SHALL BE USED. NOTIFY ENGINEER OF MISSING EMBEDMENT INFORMATION PRIOR TO IMPLEMENTATION. C)HOLES SHALL BE CLEANED THOROUGHLY BEFORE PROCEEDING WITH THE ANCHOR EMBEDMENT. D)ALL INSTALLATION REQUIREMENTS SPECIFIED BY THE MANUFACTURER MUST BE STRICTLY FOLLOWED. E)DO NOT CUT OR DAMAGE EXISTING EMBEDDED CONCRETE REINFORCEMENT DURING INSTALLATION WITHOUT PRIOR APPROVAL FROM THE ENGINEER. 10. TEMPORARY SHORING AND BRACING: A)THE GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY SHORING AND BRACING NECESSARY TO PROTECT THE STRUCTURE FROM DAMAGE DURING THE WORK. ALL SHORING AND BRACING SHALL BE DESIGNED AND INSTALLED BY QUALIFIED PERSONNEL EXPERIENCED WITH THIS SPECIFIC TYPE OF WORK. B)ALL SHORING SHALL BE FOUNDED ON STRUCTURAL ELEMENTS CAPABLE OF SUPPORTING THE LOAD. RESHORE TO LOWER LEVELS AS REQUIRED. C)PROVIDE ALL NECESSARY TEMPORARY BRACING TO HOLD STRUCTURAL COMPONENTS IN POSITION UNTIL PERMANENT BRACES AND/ OR SHEATHING ARE INSTALLED. 11. MISCELLANEOUS: A)THE GENERAL CONTRACTOR SHALL VERIFY ALL DETAILS AND DIMENSIONS BEFORE PROCEEDING WITH THE WORK. NOTIFY ENGINEER OF ANY DISCREPANCIES. B)ALL WORK SHALL COMPLY WITH THE CURRENT EDITION OF THE MASSACHUSETTS STATE BUILDING CODE, AND ANY APPLICABLE LOCAL CODES. C)THE STRUCTURAL DRAWINGS SHALL NOT BE SCALED TO OBTAIN DIMENSIONS, OFFSETS, SPACINGS, ETC. FOR ANY STRUCTURAL FRAMING MEMBERS, FOUNDATION WALLS, ETC. WRITTEN DIMENSIONS ON THE STRUCTURAL AND ARCHITECTURAL DRAWINGS SHALL BE USED. IF A CONFLICT OR DISCREPANCY IS FOUND BETWEEN WRITTEN DIMENSIONS ON ARCHITECTURAL AND STRUCTURAL DRAWINGS, THE CONTRACTOR SHALL SUBMIT A WRITTEN "REQUEST FOR INFORMATION" TO THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK. D)ALL MATERIAL, PRODUCT AND COMPONENT SUBSTITUTIONS SHALL BE PRE-APPROVED BY DAIGLE ENGINEERS, INC. AND MUST HAVE EQUAL PROPERTIES AND LOAD CARRYING CAPACITIES AS DOCUMENTED IN THE MANUFACTURER'S SPECIFICATIONS. GENERAL NOTES NEW CONCRETE FOOTING10"#4 BARS @ 12" O.C. EA. WAY NEW CONC. SLAB NEW 312" DIA. LALLY COLUMN LALLY COLUMN BASE PLATE ANCHORED (TYP.) APPROX. SCALE: 1" = 1'-0" TYPICAL FOOTING DETAIL403"26" SQUARE THOROUGHLY COMPACT SUBGRADE (TYP.) SOLID K.D. WOOD WEB INFILL - TIGHT TO FIT BCI FLOOR JOISTSJOIST HANGER FASTENED SECURELY TO BEAM 5 8"Ø THRU BOLTS @ 16" O.C. STAGGERED C BEAML WF 41 APPROX. SCALE: 3/4" = 1'-0" TYP. STEEL BEAM SECTION 42 NOT TO SCALE TYP. HOLDOWN/ STRAP DETAILS THESE MANUFACTURER DETAILS ARE FOR GENERAL REFERENCE ONLY. ALL DETAILS MAY NOT BE FULLY APPLICABLE FOR THIS PROJECT. SEE PLANS FOR ACTUAL LOCATIONS, LOAD REQUIREMENTS OR MODEL NUMBERS SPECIFIED FOR THIS PROJECT AND ADDITIONAL INFORMATION. INSTALL SIMPSON HARDWARE WITH FASTENERS PER SIMPSON SPECIFICATIONS AND GUIDELINES U.O.N. SEE GENERAL NOTES FOR ADDITIONAL INFORMATION. HDU5 (HDU2, HDU8, HDU11, and HDU14 similar) Post. See Plan or Per Simpson. CONC. ANCHOR INTO FOUND. WALL OR LAG BOLT INTO WOOD BEAM BELOW. STHD Holdown. TYPICAL HURRICANE TIE (TYPICAL AT ALL RAFTER BEARING LOCATIONS) ROOF RAFTER DOUBLE TOP PLATE (TYP.) HURRICANE TIE SEE ROOF FRAMING PLAN NOT TO SCALE TYP. HURRICANE CLIP DETAIL43