Loading...
AMENDMENT TO APPROVED MODIFICATIONS Salem Redevelopment Authority Decision 217-221 Essex Street Development Project Review—Modifications to Approved Historic Fa5ade Restoration Meeting Date: February 12, 2020 Members Present: Grace Napolitano, David Guarino, Dean Rubin, Members Absent: Russell Vickers Decision: At a regular meeting of the Salem Redevelopment Authority(SRA), upon a motion duly made and seconded, it was voted to approve the modifications to the approved historic fagade restoration work at 217- 221 Essex Street as designed and conditioned herein. Referenced Plans and Documents 1. Plan Set titled '217-221 Essex Street', prepared by Sousa Design Architects,81 Boylston Street, 2"d Floor, Brookline, MA 02445, dated 01/31/20. Sheets A-111 and A-312 have a revised date of 02/10/20. 2. Renderings titled '217-221 Essex,Amendment 1,01.31.20', prepared by Sousa Design Architects, 81 Boylston Street, 2"d Floor, Brookline, MA 02445, dated 01/31/20. 3. Letter from the City of Salem Building Inspector regarding the safety and functionality of the existing fire escapes, dated 07/12/19. 4. Staff Comments dated 02/07/20. Condition of Approval 1. Consistency with Approved Design/Plans: Should the applicant determine that the restoration project, as revised, may not be completed as presented and conditioned herein, he/she/they shall return to the DRB to review proposed modifications prior to making any changes in the field. Findings 1. Consistency with Design Standards and Guidelines:This project is consistent with the design guidelines and standards in that the existing materials are being repaired and/or replaced in-kind with no significant change to the exterior form and footprint of the structure. The architectural features on the building will be preserved and enhanced. 2. Character of the Neighborhood:The project will restore the fagade of the historic structure and improve the character of the building. This project is another significant restoration project along the Essex Street pedestrian mail that is improving the overall historic character of the neighborhood. 3. Introduction of Doorway:The project includes the construction of two new doorways on the rear fagade of the building. The new doorways provide access/egress for residents as well as access to the room that will hold the buildings'trash and recycling. These doors are not being introduced on the primary fagade thereby preserving the historical view along the Essex Street pedestrian mall. 4. Construction of Egress Stair and Rooftop Tower:The addition of the egress stair within the two buildings and the associated rooftop tower that allows access from the stair to the roof of 217 Essex Street is a historically sensitive solution to meeting modern-day safety codes. 5. National Park Service Review of PLoiect:This project has been vetted by the Massachusetts Historical Commission through the Massachusetts Historic Rehabilitation Tax Credit Program. The MHC review does not supersede review by local authorities,though if a proposal is approved by MHC and awarded a tax credit allocation,then local stakeholders have an assurance that the project is, if not wholly,then largely in compliance with the Secretary of the Interior's Standards for Rehabilitation. Signature of the SRA: By the signature below, I certify that this decision accurately reflects the actions of the SRA. — 1)�L ,--Q .GIB " ()DCz Tom Daniel,AICP Date Executive Director ISSUED FOR: SALEM REDEVELOPMENT AUTHORITY AMENDMENT REVIEW 11. DIMENSIONS ARE TO CENTER LINES, EXISTING BUILDING GRID LINES OR TO FACE OF FINISHED SURFACE UNLESS OTHERWISE NOTED. 12. ALL GYPSUM WALL BOARD CONSTRUCTION SHALL CONFORM TO RECOMMENDATIONS, PRACTICES, STANDARDS AND INSTRUCTIONS PUBLISHED BY U.S. GYPSUM COMPANY IN THE GYPSUM CONSTRUCTION HANDBOOK. 13. ALL FINISHED WORK SHALL BE FREE OF DEFECTS. THE OWNER RESERVES THE RIGHT TO REJECT ANY MATERIALS AND WORKMANSHIP WHICH ARE NOT CONSIDERED TO BE AT THE HIGHEST STANDARDS OF THE VARIOUS TRADES INVOLVED. 14. NO CHANGES OR SUBSTITUTIONS ARE ALLOWED UNLESS APPROVED BY THE ARCHITECT. 15. ANY MODIFICATION OF THESE CONSTRUCTION DOCUMENTS MUST BE APPROVED BY SOUSA DESIGN IN WRITING. 16. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, SAMPLES AND SUBMITTALS FOR ALL ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE PROJECT. 17. IN ALL CASES OF CONFLICT, THE ARCHITECTURAL DRAWINGS GOVERN. FOR LAYOUT, ALL CONFLICTS ARE TO BE IMMEDIATELY REPORTED TO THE ARCHITECT. 18. ALL MATERIALS REQUIRE A SUBMITTAL TO THE ARCHITECT FOR APPROVAL. 19. ALL WORK TO BE DONE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. ARCHITECT SHALL BE NOTIFIED OF ANY DEVIATIONS FROM ORIGINAL DRAWING SET. 20. ALL UNUSED / ABANDONED FLOOR & WALL OPENINGS SHALL BE SEALED AND FIRESTOPPED TO MATCH SPECIFIED ASSEMBLY. SOUSA design A r c h i t e c t s 1. THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECTS OF ALL DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS AND EXISTING CONDITIONS. 2. THE GENERAL CONTRACTOR SHALL COMPLY WITH ALL FEDERAL, STATE, AND LOCAL REGULATIONS THAT MAY APPLY TO THE CONSTRUCTION OF THE PROJECT. 3. ALL WORK OF THIS PROJECT SHALL COMPLY WITH ACCEPTED BUILDING PRACTICES AND ALL CODES HAVING JURISDICTION OVER THIS PROJECT. 4. REFER TO LIMITS OF WORK DRAWINGS FOR OVERALL DESCRIPTION OF WORK AREAS. 5. THE GENERAL CONTRACTOR SHALL LEAVE THE PROJECT SITE AND ALL SURROUNDING AREAS IN FINAL CLEAR CONDITION INCLUDING THE REMOVAL OF ALL DEBRIS RESULTING FROM CONSTRUCTION. 6. THE CONTRACTOR SHALL AT ALL TIMES DURING THE PROGRESS OF THE WORK REMOVE ALL CONSTRUCTION DEBRIS AND MAINTAIN A DUST FREE ENVIRONMENT FOR ALL ADJACENT AREAS. 7. THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES AND VERIFY THAT ALL CUTTING AND PATCHING REQUIRED FOR THE INSTALLATION OF ALL MATERIALS BY ALL TRADES IS PROPERLY EXECUTED. 8. THE CONTRACTOR SHALL UTILIZE THE AREAS WITHIN THE SCOPE OF WORK FOR STORAGE OF MATERIALS AND TOOLS. 9. ALL WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER ALL OTHERS. DO NOT SCALE DRAWINGS. IF THERE IS A QUESTION OR CONFLICT IN DIMENSIONS, NOTIFY THE ARCHITECT FOR CLARIFICATION. 10. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF THE WORK. THE CONTRACT DRAWINGS ARE COMPLIMENTARY AND WHAT IS REQUIRED BY ONE SHALL BE BINDING AS IF REQUIRED BY ALL. THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK. 217-221 Essex Street (Salem,MA) BLOCKING CONCRETE EARTH BATT INSULATION GRAVEL WOOD DRYWALL TILE FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FFE FINISHED FLOOR ELEVATION FIN FINISH FFL FOF FACE OF FINISH FOC FOS HVAC FC FD INSUL LEFT HAND(ED) MAX MAXIMUM PR REQ REF REFERENCE REV SD T W/WITH WC @ AT AFF ELEVATION REFERENCE DOOR NUMBER ROOM NUMBER WINDOW NUMBER ELEVATION DESIGNATION SECTION REFERENCE NEW DOOR TO BE INSTALLED EXISTING DOOR TO REMAIN 102 A NEW CONSTRUCTION EXISTING CONSTRUCTION PARTITION TYPE BUILDING CROSS SECTION STEEL 1 A-2.1 1 A-3.1 1 A-3.1 1 ARCHITECTURAL: A-000 COVER PAGE SP-1.1 PROPOSED SITE PLAN A-111 PROPOSED FIRST FLOOR PLAN A-310 PROPOSED NORTH EXTERIOR ELEVATION A-311 PROPOSED EAST EXTERIOR ELEVATION A-312 PROPOSED SOUTH EXTERIOR ELEVATION A-313 PROPOSED WEST EXTERIOR ELEVATION A-400 PROPOSED WINDOW DETAILS A-401 PROPOSED WINDOW DETAILS A-402 PROPOSED NEW SOUTH ENTRY DETAIL A-403 PROPOSED STOREFRONT DETAIL ARCHITECT: SOUSAdesign 81 Boylston Street, 2nd Floor Brookline, MA 02445 Attn:Stephen A. Sousa A.I.A. 617.879.9100 SURVEYOR: OWNER: Attn:Joe Arcari 617.776.1900 NORDE-EAST SURVEY 27 Congress Street, Suite 205-8 Salem, MA 01970 Attn:Patric McCormack 978-542-1920 BUILDING SUMMARY: TOTAL LOT AREA:Existing 3,625 SF +/- GROSS FLOOR AREA:Existing 10,875 SF +/- USE CATEGORY: Use: Existing A-3 Museum First Floor Proposed R-2 Residential ZONING DISTRICT: B5 Central Development BUILDING CODE: WORK TO BE COMPLETED IN ACCORDANCE TO: IBC - International Building Code 2015 IEBC - International Existing Building Code 2015 IECC - International Energy Conservation Code 2015 IMC - International Mechanical Code 2015 IFC - International Fire Code 2015 780 CMR - MA Amendments to the IBC 527 CMR - MA fire prevention and electrical regulations 521 CMR - MA accessibility regulations 248 CMR - MA plumbing regulations 524 CMR - MA elevator regulations CONSTRUCTION TYPE IIIB (Mixed Used) *BUILDING TO BE FULLY SPRINKLERED A-000 COVER PAGE Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 01.31.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 SP-1.1 PROPOSED PLOT PLAN Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 01.31.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 PROPOSED BASEMENT FLOOR PLAN @ 221 ESSEX ST Scale: 3/16" = 1'-0"1 UP DN F.F.L. = 0' - 0" F.F.L. = 2' - 1" F.F.L. = 1' - 3 1/2" F.F.L. = 1' - 5" F.F.L. = 0' - 0" F.F.L. = 3' - 11 1/2" F.F.L. = 1' - 4" F.F.L. = 0' - 9 1/2"DNF.F.L. = 0' - 0" F.F.L. = 0' - 5" F.F.L. = 0' - 0" F.F.L. = 0' - 0" F.F.L. = 0' - 9" F.F.L. = 0' - 0" F.F.L. = 0' - 0" F.F.L. = 0' - 0" F.F.L. = -3' - 6" F.F.L. = 0' - 0"37'-10 3/4"36'-2 5/8"24'-3 1/4"93'-1"14'-11 1/8"16'-8 5/8" F.F.L. = -3' - 6" F.F.L. = 0' - 0" DN F.F.L. = 8' - 11"5'-0"TRASH ROOM RESIDENCE LOBBY DN NEW ELEVATOR RETAIN EXISTING EGRESS DOOR STORAGE SHARE CORRIDOR NEW STAIR PROPOSED ELEVATOR ACCESS FOR TENANT DNDN DN RESIDENCE ENTRY LANDLORD EQUIPMENTS CLOSET UP UP NEW STAIR RETAIN EXISTING EGRESS DOOR 11'-4 1/2"13'-3 1/2"NEW STAIR LOCATION 1 TOP EXITSUMPIT 2'-4 3/4"5'-4"PROPOSED STILE & RAIL METAL DOOR PAINTED 1 A-111 PROPOSED FIRST FLOOR PLAN Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 01.31.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 PROPOSED NORTH ELEVATION Scale: 1/4" = 1'-0"1 First Floor 0' - 0" Second Floor 16' - 5" Third Floor 28' - 3" Fourth Floor 40' - 3" Fifth Floor 51' - 7 1/2" 14' - 11 1/2" Lower Parapet 48' - 1" Upper Parapet 63' - 10" Lower Second Floor 12'-2 1/2"3'-6 1/2"7'-10"12'-0"11'-10"1'-5 1/2"14'-11 1/2"12'-2 1/2"3'-6 1/2"7'-10"12'-0"11'-10"1'-5 1/2"14'-11 1/2"15'-6"5'-0"11'-4 3/4"NEW STAINED WOOD ENTRANCE DOOR AND HARDWARE WITH TRIM SURROUND TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON ARCHITECTURAL COMPONENTS TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON WINDOW TRIMS AND SILL TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON CORNICE COMPONETS TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON ARCHITECTURAL COMPONENTS TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON WINDOW TRIMS AND SILL TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON WINDOW TRIMS AND SILL TYPICAL RETAIN, REPAIR, AND PAINT EXISTING CAST IRON CORNICE CORNER TO MAKE LIKE NEW TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON CORNICE, SIGNAGE BAND, AND TRIMS TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON COLUMN COMPONETS TYPICAL NEW PAINTED WOOD STOREFRONT WITH TRIM SURROUND AND INSULATED CLEAR GLASS TYPICAL NEW PAINTED WOOD RECESS PANELINGS AND TRIMS UNDER STOREFRONT TYPICAL RETAIN, REPAIR, AND PAINT EXISTING EXPOSED FOUNDATION TYPICAL RETAIN AND REPAIR EXISTING MASONRY REFER TO ARCHITECTURAL MASONRY SPECS A-001 RETAIN, REPAIR, AND PAINT EXISTING WOOD CORNICE COMPONETS TO MAKE LIKE NEW TYPICAL RETAIN, REPAIR, AND PAINT EXISTING WOOD PANELING COMPONETS TO MAKE LIKE NEW TYPICAL PROPOSED NEW STAIR ENCLOSURE BEYOND ROOF LINE BALLUSTERS SLOPE ROOF BEYOND NEW METAL PANELING 18 x 24 PAINTED BRONZE FINISH NEW COPPER DRIP EDGE NEW WOOD/GLASS DOOR PAINTED EXISTING MASONRY BRICK CHIMNEY TO REMAIN EXISTING ELECTRICAL COMPONENTS TO REMAIN TYPICAL RETAIN EXISTING BLADE SIGN NEW STAINED WOOD ENTRANCE DOOR AND HARDWARE WITH TRIM SURROUND TYPICAL NEW STAINED WOOD ENTRANCE DOOR AND HARDWARE WITH TRIM SURROUND TYPICAL RETAIN, REPAIR, AND PAINT EXISTING WINDOW ARCH ANDTRIM SURROUND ABOVE DOOR RETAIN, REPAIR, AND PAINT EXISTING WINDOW FAN AND TRIM SURROUND ABOVE DOOR NEW METAL PANELING 18 x 24 PAINTED BRONZE FINISH NEW UNITS AIR COOLED CONDENSERS ON CURBS TYPICAL EXISTING AIR COOLED CONDENSERS TO REMAIN NEW ROOF MEMBRANE OVER NEW RIGID INSULATION TYPICAL NEW STAINED WOOD ENTRANCE DOOR AND HARDWARE WITH TRIM SURROUND TYPICAL NEW PAINTED WOOD ENTRANCE SIDE LITES WITH TRIM SURROUND TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN AND CLEAN EXISITNG STONE ENTABLATURE COMPONENT TO MAKE LIKE NEW TYPICAL RETAIN AND REPAIR EXISITNG MASONRY REFER TO ARCHITECTURAL MASONRY SPECS A-001 NEW COMPOSITE ROOF BALLUSTRADE TO MATCH EXISTING PAINTED TYPICAL EXISTING ROOF REMOVE EXISTING BANK CLOCK NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING CAST IRON TRIMS AND SILL TYPICAL NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING CAST IRON TRIMS AND SILL TYPICAL NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING CAST IRON TRIMS AND SILL TYPICAL 1 1 A-310 PROPOSED NORTH ELEVATION Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 01.31.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 A-311 PROPOSED EAST ELEVATION Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 01.31.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 PROPOSED EAST ELEVATION Scale: 1/4" = 1'-0"2 First Floor 0' - 0" Second Floor 16' - 5" Third Floor 28' - 3" Fourth Floor 40' - 3" Fifth Floor 51' - 7 1/2" 14' - 11 1/2" Lower Parapet 48' - 1" Upper Parapet 63' - 10" Lower Second Floor 12'-2 1/2"3'-6 1/2"7'-10"12'-0"11'-10"1'-5 1/2"14'-11 1/2"NEW COMPOSITE ROOF BALLUSTRADE TO MATCH EXISTING PAINTED TYPICAL RETAIN AND REPAIR EXISTING MASONRY REFER TO ARCHITECTURAL MASONRY SPECS RETAIN, REPAIR, AND PAINT EXISTING WOOD CORNICE COMPONENTS TO MAKE LIKE NEW TYPICAL RETAIN, REPAIR, AND PAINT EXISTING WOOD PANELING COMPONENTS TO MAKE LIKE NEW TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN, REPAIR, AND CLEAN EXISITNG STONE ENTABLATURE COMPONENT TO MAKE LIKE NEW TYPICAL RETAIN AND REPAIR EXISITNG MASONRY REFER TO ARCHITECTURAL MASONRY SPECS A-001 RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN, REPAIR, AND PAINT EXISTING VAULT ALARM RETAIN, REPAIR,AND PAINT EXISTING METAL SECURITY STEEL BAR TYPICAL NEW COMPOSITE ROOF BALLUSTRADE TO MATCH EXISTING PAINTED TYPICAL RETAIN, REPAIR, AND PAINT EXISTING WOOD CORNICE COMPONETS TO MAKE LIKE NEW TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL EXISTING ROOF PROPOSED NEW STAIR ENCLOSURE BEYOND ROOF LINE BALLUSTERS NEW COPPER DRIP EDGE REMOVE EXISTING WINDOW AND INFILL WITH BRICK MASONRY NEW METAL PANELING 18 x 24 PAINTED BRONZE FINISH RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL EXISTING WINDOW STONE SILL TO REMAIN TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL EXISTING WINDOW STONE SILL TO REMAIN TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY WITHIN EXISTING WOOD TRIMS AND SILL BEYOND METAL SECURITY STEEL BAR 1 REMOVE EXISTING BANK CLOCK 1 PROPOSED SOUTH ELEVATION Scale: 1/4" = 1'-0"3 First Floor 0' - 0" Second Floor 16' - 5" Third Floor 28' - 3" Fourth Floor 40' - 3" Fifth Floor 51' - 7 1/2" 14' - 11 1/2" Lower Parapet 48' - 1" Upper Parapet 63' - 10" Lower Second Floor 12'-2 1/2"3'-6 1/2"7'-10"12'-0"11'-10"1'-5 1/2"14'-11 1/2"1'-3 1/4"1'-2"RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN AND REPAIR EXISITNG MASONRY REFER TO ARCHITECTURAL MASONRY SPECS RETAIN, REPAIR, AND PAINT EXISTING WOOD CORNICE COMPONENTS TO MAKE LIKE NEW TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN AND REPAIR EXISITING MASONRY REFER TO ARCHITECTURAL MASONRY SPECS RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY WITH-IN EXISTING WOOD TRIMS AND SILL BEYOND METAL SECURITY STEEL BAR NEW STAINED WOOD ENTRANCE DOOR AND HARDWARE WITH TRIM SURROUND TYPICAL NEW ALUMINUM WINDOW ASSEMBLY TO MATCH EXISTING SET WITH-IN EXISTING WOOD TRIMS AND SILL TYPICAL NEW COMPOSITE ROOF BALLUSTRADE TO MATCH EXISTING PAINTED TYPICAL RETAIN, REPAIR,AND PAINT EXISTING METAL SECURITY STEEL BAR TYPICAL RETAIN, REPAIR, AND PAINT EXISTING METAL ACCESS DOOR RETAIN AND REPAIR EXISITNG MASONRY REFER TO ARCHITECTURAL MASONRY SPECS 5'-0"15'-10"EXISTING ROOF 11'-4 3/4"NEW METAL PANELING 18 x 24 PAINTED BRONZE FINISH PROPOSED NEW STAIR ENCLOSURE BEYOND ROOF LINE BALLUSTERS NEW COPPER DRIP EDGE SLOPE ROOF BEYOND EXISTING MASONRY BRICK CHIMNEY TO REMAIN NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING WOOD TRIMS AND SILL TYPICAL NEW METAL PANELING 18 x 24 PAINTED BRONZE FINISH NEW WOOD WINDOW ASSEMBLY TO MATCH EXISTING SET WITHIN NEW WOOD TRIMS AND SILL TYPICAL EXISTING GENERATOR TO REMAIN NEW RTU FOR COMMON SPACE TYPICAL NEW UNITS AIR COOLED CONDENSERS ON CURBS TYPICAL RETAIN EXISTING ROOF BALLUSTRADE NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING WOOD TRIMS AND SILL TYPICAL NEW METAL DOOR AND TRANSOM ASSEMBLY TO MATCH EXISTING TYPICAL NEW METAL DOOR PAINTED NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING WOOD TRIMS AND SILL TYPICAL NEW WOOD PANELING PAINTED 1 1 1 1 NEW FIXED METAL WINDOW TRANSOM PAINTED LINE OF EXIST WINDOW TO BE DEMOLISHED 19'-0"12'-0"4'-9 3/8"A-312 PROPOSED SOUTH ELEVATION Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 01.31.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 PROPOSED WEST ELEVATION Scale: 1/4" = 1'-0"4 First Floor 0' - 0" Second Floor 16' - 5" Third Floor 28' - 3" Fourth Floor 40' - 3" Fifth Floor 51' - 7 1/2" 14' - 11 1/2" Lower Parapet 48' - 1" Upper Parapet 63' - 10" Lower Second Floor 12'-2 1/2"3'-6 1/2"7'-10"12'-0"11'-10"1'-5 1/2"14'-11 1/2"5'-8"NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING CAST IRON TRIMS AND SILL TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON ARCHITECTURAL COMPONENTS TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON CORNICE COMPONETS TYPICAL NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING CAST IRON TRIMS AND SILL TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON ARCHITECTURAL COMPONENTS TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON WINDOW TRIMS AND SILL TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON WINDOW TRIMS AND SILL TYPICAL NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING CAST IRON TRIMS AND SILL TYPICAL RETAIN, REPAIR, AND PAINT EXISTING CAST IRON CORNICE CORNER TO MAKE LIKE NEW TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON CORNICE, SIGNAGE BAND AND TRIMS TYPICAL RETAIN, PAINT, AND CAULK EXISTING CAST IRON COLUMN COMPONETS TYPICAL NEW PAINTED WOOD STOREFRONT WITH TRIM SURROUND AND INSULATED CLEAR GLASS TYPICAL NEW PAINTED WOOD RECESS PANELINGS AND TRIMS UNDER STOREFRONT TYPICAL NEW ALUMINUM WINDOW ASSEMBLY TO MATCH EXISTING SET WITH-IN NEW WOOD TRIMS AND SILL TYPICAL NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING WOOD TRIMS AND SILL TYPICAL 1 REMOVE EXISTING BANK CLOCK REMOVE EXISTING FIRE ESCAPE STAIR ASSEMBLY A-313 PROPOSED WEST ELEVATION Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 01.31.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 217 - NEW WINDOW TYPE B & C DETAIL Scale: 1" = 1'-0"2 217 - NEW WINDOW TYPE A DETAIL Scale: 1" = 1'-0"1 217 - NEW WINDOW TYPE B DETAIL Scale: 1" = 1'-0"4 217 - NEW WINDOW TYPE A DETAIL Scale: 1" = 1'-0"3 217 - NEW WINDOW TYPE C DETAIL Scale: 1" = 1'-0"5 217 - NEW WINDOW TYPE B & C DETAIL Scale: 1" = 1'-0"3 7'-4 1/2" 2 1/8"1'-4"3 1/2"3'-8 1/2"3 1/2"1'-4"2 1/2"5 3/4"2"5 1/4"8'-9" 4"3 1/2"3'-5 7/8"6 1/4"3'-5 7/8"3 1/2"4"3 5/8"1 5/8"2"5 1/4"8'-9" 4"3 1/2"7'-6"3 1/2"4"3 5/8"1 5/8"2"5 1/4"10'-4 1/2"4"2 7/8"2 1/2"9'-7 1/8"8'-7 7/8"4"2 7/8"5'-5 1/2"3 1/8"2'-4 3/8"10'-1 1/4"4"3 1/2"4'-3 1/2"3 1/8"A-400 NEW WINDOW DETAILS Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 01.31.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 4" 3 1 2 3 4 5 NEW PAINTED ALUMINUM DOUBLE HUNG WINDOW UNIT FIT WITHIN EXISTING MASONRY OPENING (TYPICAL) CLEAN EXISTING STONE SILL REPAIR AND PAINT EXISTING WOOD BRICK MOULDING WINDOW SURROUND (TYPICAL) EXISTING MASONRY OPENING TO REMAIN (TYPICAL) REPAIR AND PAINT EXISTING WOOD SILL (TYPICAL) NEW PAINTED ALUMINUM DOUBLE HUNG WINDOW UNIT SET WITHIN EXISTING MASONRY REPAIR AND PAINT EXISTING BRICK MOULDING WINDOW SURROUND (TYPICAL) REPAIR AND PAINT EXISTING WOOD TRIM (TYPICAL) NEW WOOD BLOCKING ROUGH OPENING AS REQUIRED (TYPICAL) EXISTING MASONRY WALL TO REMAIN NEW BACKER ROD AND PAINT SEALANT (TYPICAL) NEW 7/8" FIXTURE GRILLE WITH INTERNAL GRID (TYPICAL)NEW PAINTED ALUMINUM DOUBLE HUNG WINDOW UNIT FIT WITHIN EXISTING MASONRY OPENING (TYPICAL) REPAIR AND PAINT EXISTING WOOD BRICK MOULDING WINDOW SURROUND (TYPICAL) EXISTING MASONRY OPENING TO REMAIN (TYPICAL)REPAIR AND PAINT EXISTING WOOD TRIM (TYPICAL) NEW WOOD BLOCKINGAS REQUIRED (TYPICAL) CLEAN EXISTING STONE SILL REPAIR AND PAINT EXISTING WOOD SILL (TYPICAL) EXISTING MASONRY WALL TO REMAIN NEW BACKER ROD AND PAINT SEALANT (TYPICAL) NEW PAINTED ALUMINUM DOUBLE HUNG WINDOW UNIT SET WITHIN EXISTING MASONRY NEW 7/8" FIXTURE GRILLE WITH INTERNAL GRID (TYPICAL) REPAIR AND PAINT EXISTING MOULDING TRIM WINDOW SURROUND (TYPICAL) NEW 7/8" FIXTURE GRILLE WITH INTERNAL GRID (TYPICAL) REPAIR AND PAINT EXISTING BRICK MOULDING WINDOW SURROUND (TYPICAL) EXISTING MASONRY WALL TO REMAIN REPAIR AND PAINT EXISTING WOOD SILL (TYPICAL) NEW BACKER ROD AND PAINT SEALANT (TYPICAL) REPAIR AND PAINT EXISTING MOULDING TRIM WINDOW SURROUND (TYPICAL) NEW PAINTED ALUMINUM DOUBLE HUNG WINDOW UNIT FIT WITHIN EXISTING MASONRY OPENING (TYPICAL) REPAIR AND PAINT EXISTING WOOD BRICK MOULDING WINDOW SURROUND (TYPICAL) EXISTING MASONRY OPENING TO REMAIN (TYPICAL) 217 - NEW WINDOW TYPE A ELEVATION Scale: 1/4" = 1'-0"A 217 - NEW WINDOW TYPE B & C ELEVATION Scale: 1/4" = 1'-0"B GLASS NOTES: CL. 1: Insulated clearglass with low E coating EC Argon Glazing shall meet international energy code 2015 - Requirements CL. 2: Insulated Tempered clearglass with Low E coating EC Argon Glazing shall meet international energy code 2015 - Requirements. WINDOW NOTES: 1. Provide Diamond 8101 Double Hung Aluminum frame windows as specified or equal as approved by Architect. Install windows per manufacturer recommendations. 2. Dimensions provided indicate the frame dimensions of proposed windows. 3. Verify existing framing rough openings prior to ordering of windows. Including height and radius of round windows. GC to coordinate framing requirements. 4. Install windows with aluminum sill pan flashing. Increase indicated rough opening heights as required to accommodate flashing requirements with wall framing. 5. Exterior color: to be selected by Architect from manufacturer's to review with Local Historical District. 6. Interior color: Painted to match Architect's sample. 7. Glass: 1/2" Clear, Low "E" insulated glass, argon filled; U Factor= maximum. 26 for fixed windows, maximum .30 for venting windows. 8. Provide factory weatherstripping completely around sash and frame for complete seal. Backer rods and sealant around frames. 9. Interior half firberglass Screens inside. Frame finish to be determined by Architect. 10. Hardware finish: To be determined by architect from range of manufacturer's optional finish. 11. Provide safety glass perbuilding code. 12. Contractor to see building elevations and details for elevations and alignments. 13. Fixed transom window window widths to match door widths window. 221 - NEW WINDOW TYPE A,B,C & D DETAIL Scale: 1" = 1'-0"1221 - NEW WINDOW TYPE A,B,C & D DETAIL Scale: 1" = 1'-0"2 A-401 NEW WINDOW DETAILS Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 01.31.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 2 1 EXISTING CAST IRON WINDOW TRIM TO REMAIN PAINTED TYPICAL EXISTING CAS IRON ORNAMENTAL PILASTER TO REMAIN PAINTED TYPICAL EXISTING WINDOW WOOD SILL TO REMAIN PAINTED TYPICAL EXISTING CAST IRON ORNAMENTAL MOULDINGS PAINTED TYPICAL EXISTING CAST IRON CORNICE MOULDING TO REMAIN PAINTED TYPICAL EXISTING CAST IRON WINDOW TRIM TO REMAIN PAINTED TYPICAL EXISTING WINDOW WOOD SILL TO REMAIN PAINTED TYPICAL EXISTING CAST IRON CORNICE MOULDING TO REMAIN PAINTED TYPICAL NEW PAINTED ALUMINUM DOUBLE HUNG WINDOW UNIT FIT WITHIN EXISTING MASONRY OPENING (TYPICAL) NEW PAINTED ALUMINUM DOUBLE HUNG WINDOW UNIT SET WITHIN EXISTING MASONRY OPENING TYPICAL NEW WOOD BLOCKING ROUGH OPENING AS REQUIRED (TYPICAL) NEW PAINTED ALUMINUM DOUBLE HUNG WINDOW UNIT SET WITHIN EXISTING MASONRY OPENING TYPICAL 221 - NEW WINDOW TYPE A ELEVATION Scale: 1/4" = 1'-0"A 221 - NEW WINDOW TYPE B ELEVATION Scale: 1/4" = 1'-0"B 221 - NEW WINDOW TYPE C ELEVATION Scale: 1/4" = 1'-0"C 221 - NEW WINDOW TYPE D ELEVATION Scale: 1/4" = 1'-0"D GLASS NOTES: CL. 1: Insulated clearglass with low E coating EC Argon Glazing shall meet international energy code 2015 - Requirements CL. 2: Insulated Tempered clearglass with Low E coating EC Argon Glazing shall meet international energy code 2015 - Requirements. WINDOW NOTES: 1. Provide Diamond 8101 Double Hung Aluminum frame windows as specified or equal as approved by Architect. Install windows per manufacturer recommendations. 2. Dimensions provided indicate the frame dimensions of proposed windows. 3. Verify existing framing rough openings prior to ordering of windows. Including height and radius of round windows. GC to coordinate framing requirements. 4. Install windows with aluminum sill pan flashing. Increase indicated rough opening heights as required to accommodate flashing requirements with wall framing. 5. Exterior color: to be selected by Architect from manufacturer's to review with Local Historical District. 6. Interior color: Painted to match Architect's sample. 7. Glass: 1/2" Clear, Low "E" insulated glass, argon filled; U Factor= maximum. 26 for fixed windows, maximum .30 for venting windows. 8. Provide factory weatherstripping completely around sash and frame for complete seal. Backer rods and sealant around frames. 9. Interior half firberglass Screens inside. Frame finish to be determined by Architect. 10. Hardware finish: To be determined by architect from range of manufacturer's optional finish. 11. Provide safety glass perbuilding code. 12. Contractor to see building elevations and details for elevations and alignments. 13. Fixed transom window window widths to match door widths window. 217 - SOUTH ENTRY WINDOW DETAIL Scale: 1" = 1'-0"2 217 - SOUTH ENTRY DOOR DETAIL Scale: 1" = 1'-0"1 217 - SOUTH ENTRY WINDOW & DOOR DETAIL Scale: 1" = 1'-0"3 6'-0" 2 1/2"11 1/2"3 1/2"3'-0 3/4"3 1/2"11 1/2"2 1/2"5 3/4"2"5 1/4"3'-6 5/8"2 1/2"3'-4 1/8"1 3/4"2'-6 3/8"1 1 6'-0" 3'-0"1'-6"1'-6"9 5/8"8 1/4"7'-8 5/8"4 3/8"2'-8 1/2"2 3/8"1 A-402 NEW SOUTH ENTRY WINDOW & DOOR DETAIL Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 01.31.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 1 2 3 3 NEW PAINTED ALUMINUM DOUBLE HUNG WINDOW AND FIXED UNIT FIT WITHIN EXISTING MASONRY OPENING (TYPICAL) NEW PAINTED WOOD BRICK MOULDING WINDOW SURROUND (TYPICAL) EXISTING MASONRY OPENING TO REMAIN (TYPICAL) NEW WOOD BLOCKING AS REQUIRED (TYPICAL) NEW PAINTED WOOD WINDOW SILL TYPICAL NEW PAINTED WOOD BRICK MOULDING WINDOW SURROUND (TYPICAL) EXISTING MASONRY WALL TO REMAIN NEW PAINTED WOOD PANELING TYPICAL NEW COPPER CAP FLASHING TYPICAL 217 - NEW SOUTH ENTRY ELEVATION Scale: 1/4" = 1'-0"A NEW PAINTED WOOD TRIM TYPICAL NEW PAINTED ALUMINUM DOUBLE HUNG WINDOW UNIT SET WITHIN EXISTING MASONRY NEW PAINTED WOOD STILE AND RAIL DOOR WITH SOLID RAISED PANELS TYPICAL EXISTING MASONRY OPENING TO REMAIN (TYPICAL) EXISTING MASONRY OPENING TO REMAIN (TYPICAL) NEW PAINTED WOOD STILE AND RAIL DOOR SIDE LIGHTS WITH SOLID RAISED PANELS AND INSULATED GLASS TYPICAL NEW PAINTED WOOD DOOR FRAME TYPICAL NEW PAINTED WOOD TRIM TYPICAL NEW PAINTED WOOD PANELING TYPICAL NEW PAINTED WOOD CROWN MOULDING TYPICAL NEW PAINTED WOOD WINDOW TYPICAL NEW PAINTED WOOD WINDOW TRIM TYPICAL NEW PAINTED WOOD STILE AND RAIL DOOR WITH SOLID RAISED PANELS TYPICAL NEW METAL THRESHOLD ADA TYPICAL GLASS NOTES: CL. 1: Insulated clearglass with low E coating EC Argon Glazing shall meet international energy code 2015 - Requirements CL. 2: Insulated Tempered clearglass with Low E coating EC Argon Glazing shall meet international energy code 2015 - Requirements. WINDOW NOTES: 1. Provide Diamond 8101 Double Hung Aluminum frame windows as specified or equal as approved by Architect. Install windows per manufacturer recommendations. 2. Provide Pella Architectural Series Wood Double Hung and Fixed Windows as specified or equal as approved by Architect. Intall windows per manufacturer 2. Dimensions provided indicate the frame dimensions of proposed windows. 3. Verify existing framing rough openings prior to ordering of windows. Including height and radius of round windows. GC to coordinate framing requirements. 4. Install windows with aluminum sill pan flashing. Increase indicated rough opening heights as required to accommodate flashing requirements with wall framing. 5. Exterior color: to be selected by Architect from manufacturer's to review with Local Historical District. 6. Interior color: Painted to match Architect's sample. 7. Glass: 1/2" Clear, Low "E" insulated glass, argon filled; U Factor= maximum. 26 for fixed windows, maximum .30 for venting windows. 8. Provide factory weatherstripping completely around sash and frame for complete seal. Backer rods and sealant around frames. 9. Interior half firberglass Screens inside. Frame finish to be determined by Architect. 10. Hardware finish: To be determined by architect from range of manufacturer's optional finish. 11. Provide safety glass perbuilding code. 12. Contractor to see building elevations and details for elevations and alignments. 13. Fixed transom window window widths to match door widths window. 221 - NEW STOREFRONT DETAIL Scale: 1" = 1'-0"3 221 - NEW STOREFRONT DETAIL Scale: 1" = 1'-0"22'-10 1/2"5"6'-11 1/2"1 3/8"2'-1 1/4"2'-10 1/2"5"2 1/2"2 1/2"1'-3 5/8"4"7'-6"A-403 NEW STOREFTONT DETAILS Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 01.31.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 8 7/8"11'-7 1/8"1'-1 1/2"11'-4 3/8"9 1/8"11'-4 5/8"1'-1 1/2"1'-1 1/2"5'-0"8 1/4"2'-6 3/8"4'-6 1/2"2' - 9 1 / 4 " 6'-0" RETAIN, REPAIR AND REPAINT CAST IRON ORNAMENTAL COLUMN COVER TYPICAL NEW PAINTED WOOD STOREFRONT TYPICAL 221- NEW STOREFRONT ELEVATION Scale: 1/4" = 1'-0"B 221 - NEW STOREFRONT DETAIL Scale: 1/4" = 1'-0"1 2 1 3 NEW PAINTED WOOD STOREFRONT TYPICAL RETAIN, REPAIR AND REPAINT CAST IRON ORNAMENTAL COLUMN COVER TYPICAL NEW PAINTED WOOD STOREFRONT TYPICAL NEW PAINTED WOOD STILE AND RAIL WITH GLASS ENTRY DOORS TYPICAL RETAIN, REPAIR AND REPAINT EXISTING CEILING TYPICAL NEW PAINTED WOOD TRIM TYPICAL 221- NEW STOREFRONT ELEVATION Scale: 1/4" = 1'-0"A RETAIN, REPAIR AND REPAINT CAST IRON ORNAMENTAL COLUMN COVER TYPICAL NEW PAINTED WOOD STOREFRONT TYPICAL NEW PAINTED WOOD TRIMS TYPICAL RETAIN, REPAIR AND REPAINT CAST IRON ORNAMENTAL COLUMN COVER TYPICAL NEW PAINTED WOOD STOREFRONT TYPICAL RETAIN, REPAIR AND REPAINT CAST IRON ORNAMENTAL COLUMN COVER TYPICAL NEW PAINTED WOOD TRANSOM TYPICAL NEW PAINTED WOOD TRIM TYPICAL NEW PAINTED SIMULATED DIVIDED LIGHTS WITH SPACERS TYPICAL NEW PAINTED WOOD TRIM TYPICAL NEW PAINTED WOOD STOREFRONT TYPICAL NEW PAINTED WOOD WINDOW SILL TYPICAL NEW PAINTED WOOD PANELS TYPICAL RETAIN, REPAIR AND REPAINT CAST IRON ORNAMENTAL COLUMN COVER TYPICAL NEW PAINTED WOOD TRANSOM TYPICAL NEW PAINTED WOOD TRIM TYPICAL NEW PAINTED SIMULATED DIVIDED LIGHTS WITH SPACERS TYPICAL NEW PAINTED WOOD TRIM TYPICAL NEW PAINTED WOOD STOREFRONT TYPICAL NEW PAINTED WOOD WINDOW SILL TYPICAL NEW PAINTED WOOD PANELS TYPICAL NEW PAINTED WOOD STILE AND RAIL WITH GLASS ENTRY DOORS TYPICAL GLASS NOTES: CL. 1: Insulated clearglass with low E coating EC Argon Glazing shall meet international energy code 2015 - Requirements CL. 2: Insulated Tempered clearglass with Low E coating EC Argon Glazing shall meet international energy code 2015 - Requirements. WINDOW NOTES: 1. Provide Diamond 8101 Double Hung Aluminum frame windows as specified or equal as approved by Architect. Install windows per manufacturer recommendations. 2. Provide Pella Architectural Series Wood Storefront and Transoms as specified or equal as approved by Architect. Intall windows per manufacturer 2. Dimensions provided indicate the frame dimensions of proposed windows. 3. Verify existing framing rough openings prior to ordering of windows. Including height and radius of round windows. GC to coordinate framing requirements. 4. Install windows with aluminum sill pan flashing. Increase indicated rough opening heights as required to accommodate flashing requirements with wall framing. 5. Exterior color: to be selected by Architect from manufacturer's to review with Local Historical District. 6. Interior color: Painted to match Architect's sample. 7. Glass: 1/2" Clear, Low "E" insulated glass, argon filled; U Factor= maximum. 26 for fixed windows, maximum .30 for venting windows. 8. Provide factory weatherstripping completely around sash and frame for complete seal. Backer rods and sealant around frames. 9. Interior half firberglass Screens inside. Frame finish to be determined by Architect. 10. Hardware finish: To be determined by architect from range of manufacturer's optional finish. 11. Provide safety glass perbuilding code. 12. Contractor to see building elevations and details for elevations and alignments. 13. Fixed transom window window widths to match door widths window. SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879. 9100 217-221 Essex Amendment 1 01.31.20 217-221 Essex Street Salem, MA 01970 217 DERBY SQ.HIGGINSON SQ.ESSEX ST .SALEM GREEN221 217 1. VIEW FROM ESSEX STREET 1 1. ESSEX STREET 217-221 Essex Amendment 1 01.30.20 217-221 Essex Street Salem, MA 01970 SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879. 9100 217 DERBY SQ.HIGGINSON SQ.ESSEX ST .SALEM GREEN221 217 2. VIEW FROM SALEM GREEN 2. SALEM GREEN 2 217 DERBY SQ.HIGGINSON SQ.ESSEX ST .SALEM GREEN221 217 SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879. 9100 217-221 Essex Amendment 1 01.31.20 217-221 Essex Street Salem, MA 01970 3. VIEW FROM DERBY SQUARE 3 3. DERBY SQUARE PROPOSED BASEMENT FLOOR PLAN @ 221 ESSEX ST Scale: 3/16" = 1'-0"1 UP DN DNDN TRASH ROOM RESIDENCE LOBBYDN NEW ELEVATOR RETAIN EXISTING EGRESS DOOR STORAGE SHARE CORRIDOR NEW STAIR DNDN DN LANDLORD EQUIPMENTS CLOSET UP UP NEW STAIR RETAIN EXISTING EGRESS DOOR NEW STAIR LOCATION PROPOSED STILE & RAIL METAL DOOR PAINTED EXISTING MASONRY WALLS TO REMAIN EXISTING GLASS BLOCK WALL TO REMAIN NEW RESIDENCE ENTRY - DOOR AND TRANSOM ASSEMBLY IN PLACE OF EXISTING WINDOW NEW DEMISING WALL MAIL NEW MAIL AREA PROPOSED STILE & RAIL METAL DOOR PAINTED TOP EXITSUMPIT 1 1 A-111 PROPOSED FIRST FLOOR PLAN Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 02.10.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 PROPOSED SOUTH ELEVATION Scale: 1/4" = 1'-0"3 First Floor 0' - 0" Second Floor 16' - 5" Third Floor 28' - 3" Fourth Floor 40' - 3" Fifth Floor 51' - 7 1/2" 14' - 11 1/2" Lower Parapet 48' - 1" Upper Parapet 63' - 10" Lower Second Floor 12'-2 1/2"3'-6 1/2"7'-10"12'-0"11'-10"1'-5 1/2"14'-11 1/2"1'-3 1/4"1'-2"RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN AND REPAIR EXISITNG MASONRY REFER TO ARCHITECTURAL MASONRY SPECS RETAIN, REPAIR, AND PAINT EXISTING WOOD CORNICE COMPONENTS TO MAKE LIKE NEW TYPICAL RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY SET WITHIN EXISTING WOOD TRIMS AND SILL TYPICAL RETAIN AND REPAIR EXISITING MASONRY REFER TO ARCHITECTURAL MASONRY SPECS RETAIN, REPAIR, AND PAINT WOOD WINDOW ASSEMBLY WITH-IN EXISTING WOOD TRIMS AND SILL BEYOND METAL SECURITY STEEL BAR NEW COMPOSITE ROOF BALLUSTRADE TO MATCH EXISTING PAINTED TYPICAL RETAIN, REPAIR,AND PAINT EXISTING METAL SECURITY STEEL BAR TYPICAL RETAIN, REPAIR, AND PAINT EXISTING METAL ACCESS DOOR RETAIN AND REPAIR EXISITNG MASONRY REFER TO ARCHITECTURAL MASONRY SPECS 5'-0"15'-10"EXISTING ROOF 11'-4 3/4"NEW METAL PANELING 18 x 24 PAINTED BRONZE FINISH PROPOSED NEW STAIR ENCLOSURE BEYOND ROOF LINE BALLUSTERS NEW COPPER DRIP EDGE SLOPE ROOF BEYOND EXISTING MASONRY BRICK CHIMNEY TO REMAIN NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING WOOD TRIMS AND SILL TYPICAL NEW METAL PANELING 18 x 24 PAINTED BRONZE FINISH NEW WOOD WINDOW ASSEMBLY TO MATCH EXISTING SET WITHIN NEW WOOD TRIMS AND SILL TYPICAL EXISTING GENERATOR TO REMAIN NEW RTU FOR COMMON SPACE TYPICAL NEW UNITS AIR COOLED CONDENSERS ON CURBS TYPICAL RETAIN EXISTING ROOF BALLUSTRADE NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING WOOD TRIMS AND SILL TYPICAL NEW METAL DOOR AND TRANSOM ASSEMBLY TO MATCH EXISTING TYPICAL NEW METAL DOOR PAINTED NEW ALUMINUM WINDOW SASH TO MATCH EXISTING SET WITH-IN EXISTING WOOD TRIMS AND SILL TYPICAL NEW WOOD PANELING (PAINTED) 1 1 1 1 NEW FIXED METAL WINDOW TRANSOM PAINTED 9'-0"2'-0"4'-9 3/8"EXISTING GLASS BLOCK WALL TO REMAIN NEW RESIDENCE ENTRY DOOR AND TRANSOM ASSEMBLY IN PLACE OF WINDOW 111 A-312 PROPOSED SOUTH ELEVATION Revisions Job # Drawn by Ckd by Date SOUSA design A r c h i t e c t s 81 Boylston St., 2nd Floor Brookline, MA. 02445 617 . 879 . 9100 www.sousadesign.com 217-221 Essex Street Salem, MA 01970 ISSUED FOR: ALL DRAWINGS, SPECIFICATIONS AND ARCHITECTURAL DESIGNS ARE THE PROPERTY OF SOUSA DESIGN ARCHITECTS AND SHALL NOT BE REPRODUCED OR USED ON THIS OR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS ON SITE PRIOR TO BEGINNING ANY WORK, REPORT ALL DISCREPANCIES IN WRITING TO SOUSA DESIGN ARCHITECTS BEFORE PROCEEDING WITH THE WORK, AND SHALL ACCEPT FULL RESPONSIBILITY FOR SAME. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, AND TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT. EACH CONTRACTOR SHALL SUBMIT TO SOUSA DESIGN ARCHITECTS FOR APPROVAL; SHOP DRAWINGS, SAMPLES, CUTS OF ALL THE ITEMS OF WORK PRIOR TO THEIR INCLUSION IN THE CONSTRUCTION. ALL ITEMS TO BE INCLUDED SHALL BE APPROVED FOR USE IN THE CITY OF SALEM AND SHALL HAVE AN ASTM AND UL NUMBER WHEN SUCH ITEMS REQUIRE THIS DESIGNATION. EACH CONTRACTOR SHALL CO-ORDINATE HIS WORK WITH ALL OTHER CONTRACTORS. THE QUALITY OF WORKMANSHIP AND MATERIALS USED SHALL COMPLY WITH ALL CITY OF SALEM AND MA STATE BUILDING CODES. DRAWINGS SUBJECT TO APPROVAL BY ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION ALL NEW CONSTRUCTION TO COMPLY WITH APPLICABLE HANDICAPPED ACCESSIBILITY LAWS. 02.10.2020 SDA S.A.S. SRA REVIEW AMENDMENT 1 1863 1 Amendment 01.31.20 CITY OF SALEM, MASSACHUSETTS +{� BUILDING DEPARTMENT 120 W ASHINGTON STREET,3RD FLOOR TEL. (978) 745-9595 F Ax(978) 740-9846 KIMBERLEY DRISCOLL MAYOR THOMAS ST.PIERRE DIRECTOR OF PUBLIC PROPERTY/BUILDING COMMISSIONER July 12, 2019 Vu Alexander Sousa Design Architects,Inc. 81 Boylston Street Brookline Ma. 02445 RE: Fire escapes at 217 and 221 Essex Street, Salem Dear Mr. Alexander, Thank You for meeting with me recently to review the plans for 217 and 221 Essex Street.As we discussed,the existing fire escapes ,located on the South Elevation of 217 Essex Street and on the West elevation of 221 Essex Street are in deteriorated condition and do not meet current Building Codes. Due to their condition and noncompliance with current building code requirements,the fire escapes should be removed from the two buildings as part of the planned project and an alternative means of egress should be developed. In their existing condition,the fire escapes pose a safety concern for the building's future tenants as well as the Public. The new egress for the building will need to meet the current code requirements . I look forward to reviewing your plans for the new secondary means of egress and for the entire project. Sincerely, -� Thomas St.Pierre