UTS Job 23299 Report 11 Compressive Strength Report - Concrete 01-14-2020-Page 1 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 01-14-2020Compressive Strength Report - Concrete Report No.11 Distribution Copy Job Number 23299 Project North Building,136 Canal St.,Salem, MA Contractor Symes Associates Concrete Co.J.G. Maclellan ALL FIELD TESTS DONE ACCORDING TO ASTM:C-172 C-31 C-143 C-1064 C-39 C-1231ALL COMPRESSIVE STRENGTH TESTS DONE ACCORDING TO ASTM: CLASS CONCRETE:4000# 3/4" *No. Of Sets:3 51CUBIC YARDS: SET 1 LOCATION:SOG: Southeast limits of placement Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type F831 4.00 x 8.00 12.57 Good 01/14/20 01/21/20 7 38,000 3,020 4 F832 4.00 x 8.00 12.57 Good 01/14/20 01/28/20 14 46,000 3,660 3 F833 4.00 x 8.00 12.57 Good 01/14/20 02/11/20 28 61,000 4,850 2 F834 4.00 x 8.00 12.57 Good 01/14/20 02/11/20 28 58,500 4,650 3 F835 4.00 x 8.00 12.57 Good 01/14/20 02/11/20 28 67,000 5,330 4 Slump (in.)6 3/4 Air Temp. (F.)53 Conc Temp (F)66 Truck No.189 Ticket No.9534 Time 8:20 Unit Wt lbs/cu ft Air Content (%) SET 2 LOCATION:SOG: Northeast limits of placement Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type F826 4.00 x 8.00 12.57 Good 01/14/20 01/21/20 7 33,500 2,670 3 F827 4.00 x 8.00 12.57 Good 01/14/20 01/28/20 14 45,000 3,580 2 F828 4.00 x 8.00 12.57 Good 01/14/20 02/11/20 28 59,000 4,690 4 F829 4.00 x 8.00 12.57 Good 01/14/20 02/11/20 28 58,000 4,610 3 F830 4.00 x 8.00 12.57 Good 01/14/20 02/11/20 28 62,500 4,970 4 Slump (in.)8 Air Temp. (F.)53 Conc Temp (F)63 Truck No.249 Ticket No.9535 Time 8:50 Unit Wt lbs/cu ft Air Content (%) SET 3 LOCATION:SOG: Northwest limits of placement Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type F836 4.00 x 8.00 12.57 Good 01/14/20 01/21/20 7 40,000 3,180 5 F837 4.00 x 8.00 12.57 Good 01/14/20 01/28/20 14 54,000 4,300 3 F838 4.00 x 8.00 12.57 Good 01/14/20 02/11/20 28 67,000 5,330 2 F839 4.00 x 8.00 12.57 Good 01/14/20 02/11/20 28 69,000 5,490 5 F840 4.00 x 8.00 12.57 Good 01/14/20 02/11/20 28 65,000 5,170 4 Slump (in.)5 3/4 Air Temp. (F.)53 Conc Temp (F)65 Truck No.160 Ticket No.9537 Time 10:00 Unit Wt lbs/cu ft Air Content (%) GENERAL REMARKS:Cylinders received on 1-15-2020. *Fibermesh. Inspector Premium Travel Name Time Hours Time M. Chace No Min Day 1 Hr(s) Page 2 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 01-14-2020Compressive Strength Report - Concrete Report No.11 Distribution Copy Job Number 23299 Project North Building,136 Canal St.,Salem, MA Contractor Symes Associates Concrete Co.J.G. Maclellan REVIEWED BY:Bryan M. Crabtree FRACTURE TYPES Type 1 Type 2 Type 3 Type 4 Type5 Type 6 Reasonably well-formed Well-formed cone on Columner vertical Diagonal fracture Side fractures at top Similar to Type 5 cones on both ends,one end, vertical cracks cracking through with no cracking or bottom (occur but end of less than 1 in.running through caps,both ends, no through ends; tap commonly with cylinder is [25 mm] of cracking no well-defined cone well-formed cones with hammer to unbonded caps)pointed throught caps on other end distinguish from Type 1 Our reports are available in PDF form via email. Please email us at reports@utsofmass.com for more information. cc:Symes Associates, Inc. Mark Livesey Symes Associates, Inc. Accounts Payable Seger Architects Dan Ricciarelli McBrie, LLC Michael Perham, P.E. McBrie, LLC Bob Whitton City of Salem Steve Cummings Meninno Construction Tom Pascuccio Page 3 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 01-14-2020Compressive Strength Report - Concrete Report No.11 Distribution Copy Job Number 23299 Project North Building,136 Canal St.,Salem, MA Contractor Symes Associates Concrete Co.J.G. Maclellan FIELD SUMMARY REPORT Total Pour:SOG, middle section of building; Method of Placement:Pump Chute Discharge Bucket OtherX Other: Vibrator OtherMethod of Concrete Consolidation:X Other:hand tools Cylinder Fabrication Location:Truck Discharge Chute End of Pump HoseX Cylinder Storage:Curing Box Thermal Blanket Hay/Straw Trailer FieldX Other Placement Protection:Thermal Blankets Heat NoneX Other Slump Specification (in.)4 to 6 Number of slumps out of specification reported to If rejected Approved by Remarks: