BHCM MAINTENANCE FACILITY PROJECT January 17,2020 Mr.Thomas St. Pierre Inspectional Services Director Salem City Hall 93 Washington Street Salem,Massachusetts 01970 Re: BHCM Maintenance Facility Project— 1 White Street, Salem, MA Mr. St. Pierre: The following outlines the Intended use group(s) for the above referenced project: Original Planning Board Approval- Bloom Architects—"A03" Code Analysis Drawing—Dated 03/28/18 (Part of the original Planning Board approval set Use Group Classifications—Mixed Use F-1 - Factory Moderate Hazard B-1 -Business Livermore—Architecture, Inc. Building Code review— Use Group Classifications—Mixed Use F-1 -Factory Moderate Hazard Allowing but not limited to boat repair finishing—engine repair(including rebuilding) B-1 -Business If you have any questions regarding this project,please call my office. Sincerely yours, i-11� \ (4, t rmor til--1.. _ Pr• ,ct A- ect 7109' S /Us- ' roup ltr#1 Livermore — Architecture, Inc. 53 Mason Street — Suite #204 Salem, Massachusetts 01970 978.828.4006 livdev61@gmail.com USE AND OCCUPANCY CLASSIFICATION Courtrooms Professional services(architects,attorneys,dentists, Dance halls(not including food or drink consumption) physicians,engineers,etc.) Exhibition halls Radio and television stations Funeral parlors Telephone exchanges Gymnasiums(without spectator seating) Training and skill development not in a school or Indoor swimming pools(without spectator seating) academic program(this shall include,but not be limited Indoor tennis courts(without spectator seating) to, tutoring centers,martial arts studios,gymnastics and Lecture halls similar uses regardless of the ages served,and where not Libraries classified as a Group A occupancy). Museums 304.2 Definitions.The following terms are defined in Chap- Places of religious worship ter 2: Pool and billiard parlors Waiting areas in transportation terminals AMBULATORY CARE FACILITY. 303.5 Assembly Group A-4.Group A-4 occupancy includes CLINIC,OUTPATIENT. assembly uses intended for viewing of indoor sporting events and activities with spectator seating including,but not limited SECTION 305 to: EDUCATIONAL GROUP E Arenas 305.1 Educational Group E. Educational GroupE occu- Skating rinks anc includes, amongothers, the use of a or struc- Swimming pools pancy building Tennis courts ture, or a portion thereof, by six or more persons at any one time for educational purposes through the 12th grade. 303.6 Assembly Group A-5.Group A-5 occupancy includes assembly uses intended for participation in or viewing out- 305.1.1 Accessory to places of religious worship. Reli- gious educational rooms and religious auditoriums, which door activities including,but not limited to: are accessory to places of religious worship in accordance Amusement park structures with Section 303.1.4 and have occupant loads of less than Bleachers 100 per room or space, shall be classified as Group A-3 Grandstands occupancies. Stadiums 305.2 GroupE, daycare facilities. This group includes buildings and structures or portions thereof occupied by more SECTION 304 than five children older than 21/2 years of age who receive BUSINESS GROUP B educational, supervision or personal care services for fewer 304.1 Business Group B. Business Group B occupancy than 24 hours per day. includes,among others,the use of a building or structure,or a 305.2.1 Within places of religious worship. Rooms and portion thereof,for office,professional or service-type trans- spaces within places of religious worship providing such actions, including storage of records and accounts. Business day care during religious functions shall be classified as occupancies shall include, but not be limited to, the follow- part of the primary occupancy. ing: 305.2.2 Five or fewer children. A facility having five or Airport traffic control towers fewer children receiving such day care shall be classified Ambulatory care facilities as part of the primary occupancy. Animal hospitals,kennels and pounds 305.2.3 Five or fewer children in a dwelling unit. A Banks facility such as the above within a dwelling unit and hav- Barber and beauty shops ing five or fewer children receiving such day care shall be Car wash classified as a Group R-3 occupancy or shall comply with Civic administration the International Residential Code. Clinic, outpatient Dry cleaning and laundries:pick-up and delivery stations and self-service SECTION 306 Educational occupancies for students above the 12th grade FACTORY GROUP F Electronic data processing 306.1 Factory Industrial Group F.Factory Industrial Group Food processing establishments and commercial kitchens F occupancy includes, among others,the use of a building or not associated with restaurants, cafeterias and similar structure,or a portion thereof,for assembling,disassembling, dining facilities not more than 2,500 square feet(232 m2) fabricating, finishing, manufacturing, packaging, repair or in area. processing operations that are not classified as a Group H Laboratories:testing and research hazardous or Group S storage occupancy. Motor vehicle showrooms Post offices 306.2 Moderate-hazard factory industrial, Group F-1. Print shops Factory industrial uses that are not classified as Factory Industrial F-2 Low Hazard shall be classified as F-1 Moder- 42 2015 INTERNATIONAL BUILDING CODE® USE AND OCCUPANCY CLASSIFICATION ate Hazard and shall include,but not be limited to,the follow- Brick and masonry ing: Ceramic products Aircraft(manufacturing,not to include repair) Foundries Appliances Glass products Athletic equipment Gypsum Automobiles and other motor vehicles Ice Bakeries Metal products(fabrication and assembly) Beverages:over 16-percent alcohol content Bicycles Boats SECTION 307 Brooms or brushes HIGH-HAZARD GROUP H Business machines [F] 307.1 High-hazard Group H. High-hazard Group H Cameras and photo equipment occupancy includes, among others, the use of a building or Canvas or similar fabric structure, or a portion thereof, that involves the manufactur- Carpets and rugs(includes cleaning) ing,processing,generation or storage of materials that consti- Clothing tute a physical or health hazard in quantities in excess of Construction and agricultural machinery those allowed in control areas complying with Section 414, Disinfectants based on the maximum allowable quantity limits for control Dry cleaning and dyeing areas set forth in Tables 307.1(1) and 307.1(2). Hazardous Electric generation plants occupancies are classified in Groups H-1, H-2,H-3,H-4 and Electronics H-5 and shall be in accordance with this section, the require- Engines(including rebuilding) ments of Section 415 and the International Fire Code. Haz- Food processing establishments and commercial kitchens ardous materials stored, or used on top of roofs or canopies, not associated with restaurants, cafeterias and similar shall be classified as outdoor storage or use and shall comply dining facilities more than 2,500 square feet(232 m2)in with the International Fire Code. area. Furniture [F]307.1.1 Uses other than Group H.An occupancy that Hemp products stores,uses or handles hazardous materials as described in Jute prpducs one or more of the following items shall not be classified Laundries as Group H,but shall be classified as the occupancy that it most nearly resembles. Leather products Machinery 1. Buildings and structures occupied for the applica- Metals tion of flammable finishes, provided that such Millwork(sash and door) buildings or areas conform to the requirements of Motion pictures and television filming(without Section 416 and the International Fire Code. spectators) 2. Wholesale and retail sales and storage of flamma- Musical instruments ble and combustible liquids in mercantile occu- Optical goods pancies conforming to the International Fire Paper mills or products Code. Photographic film Plastic products 3. Closed piping system containing flammable or Printing or publishing combustible liquids or gases utilized for the opera- Recreational vehicles tion of machinery or equipment. Refuse incineration 4. Cleaning establishments that utilize combustible Shoes liquid solvents having a flash point of 140°F Soaps and detergents (60°C) or higher in closed systems employing Textiles equipment listed by an approved testing agency, Tobacco provided that this occupancy is separated from all Trailers other areas of the building by 1-hour fire barriers Upholstering constructed in accordance with Section 707 or I- Wood;distillation hour horizontal assemblies constructed in accor- Woodworking(cabinet) dance with Section 711,or both. 306.3 Low-hazard factory industrial, Group F-2. Factory 5. Cleaning establishments that utilize a liquid sol- industrial uses that involve the fabrication or manufacturing vent having a flash point at or above 200°F of noncombustible materials that during finishing,packing or (93°C). processing do not involve a significant fire hazard shall be classified as F-2 occupancies and shall include, but not be 6. Liquor stores and distributors without bulk stor- limited to,the following: age. Beverages: up to and including 16-percent alcohol content 7. Refrigeration systems. 2015 INTERNATIONAL BUILDING CODE® 43