0019 SALEM STREET - BUILDING INSPECTION ` NILSSON-SIDEN ASSOCIATESiNC.
ARCHITECTURE INTERIOR DESIGN PLANNING
July 29, 2008
EDWARD O.NILSSON,AIA,NCARB
.Salem Public Property/Building Dept. GARY J.SIDEN,AIA,NCARB
120 Washington Street
Salem, MA 01970
Attention: Joseph E. Barbeau, Jr., Assistant Building Inspector
Re: Beauty Salon - 19 Salem St., Salem,MA 01970
Application for building permit—Change in Use
Dear Mr. Barbeau:
We enclose the following Bldg. Code section 3404 summary for the above referenced
property:
Project information:
Tenant area: 784+ sf, 1st Floor tenant space
Use Group (B) Business Use. Previous Use: (A-4) Religious Use.
Occupancy: Proposed maximum occupancy= 8 (based on 784sf/ 100sf/person)
Constr. Type: 3B -Unprotected Noncombustible/Combustible
Code section 3404.0 requirements regarding alterations to existing buildings are as follows:
3404.1 Existing building w/hazard index 3404.9 Height and area limitations Table 503
decrease of 2 (4 to 2). allows 2 sty and 9600sf.
3404.2 Existing building w/ same features 3404.10 No further compliance required.
34043 Existing building components (i.e., 3404.11 -N.A.
heating system) to remain. 3404.12 -N.A.
3404.4 No new work—furnishings only. 3404.13 -N.A.
3404.5 Existing single egress per Table 3404.14 -N.A.
1017.2. (<50 persons & <75 ft.) 3404.15 -N.A.
3404.6 Proposed egress capacity (36") 3404.16 -N.A.
exceeds max. occupancy load of 3404.17 -N.A.
784sf/ 100sf/p=8 (x 0.2= 1.6"). 3404.18 Existing to remain—no new work
3404.7 Exit sign and lights currently exist. 3404.19 No change to building envelope.
3404.8 Egress lighting provided.
Please advise if you have any questions on the above.
Very truly yours,
aye PSD NI�s icy
NILSSON+ SIDEN ASSOCIATES,INC. t 3
W° No. 4011 Z
CAMMAIDGE. y�
;+S MASS.
Edward O. Nilsson, AIA,Principal oy�FAt7"Of M�Sy�Gr
Cc: Michael Viola, Files 262 Essex Street,Salem,Massachusetts 01970
(978)741-5777 FAX(978)741-0557
E-mail:mail@nsaarch.com