UTS Job 23418 Report 10 Compressive Strength Report - Mortar 12-20-2019-Page 1
5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax)
Report Date 12-20-2019Compressive Strength Report - Mortar
Report No.10
Distribution Copy Job Number 23418
Project Halstead Salem Station, 72 Flint Street
Salem, MA
Contractor Fulcrum Associates
Concrete Co.Aggregate Industries
ALL FIELD TESTS DONE ACCORDING TO ASTM:C-1064 C-270
C-109ALL COMPRESSIVE STRENGTH TESTS DONE ACCORDING TO ASTM:
CLASS MORTAR:Type S-1800#No. Of Sets:1
SET 1 LOCATION:Building 2 elevator shaft, 14th course
Total Unit
Lab Size Area Date Date Age Load Load
No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)
B654 2 x 2 x 2 4.00 Good 12/20/2019 01/02/2020 13 4,500 1,130
B655 2 x 2 x 2 4.00 Good 12/20/2019 01/02/2020 13 7,500 1,880
B656 2 x 2 x 2 4.00 Good 12/20/2019 01/02/2020 13 5,500 1,380
B657 2 x 2 x 2 4.00 Good 12/20/2019 01/17/2020 28
B658 2 x 2 x 2 4.00 Good 12/20/2019 01/17/2020 28
B659 2 x 2 x 2 4.00 Good 12/20/2019 01/17/2020 28
Air Temp. (F.)54
Mortar Temp (F)42
Time 12:45
GENERAL REMARKS:
Inspector Premium Travel
Name Time Hours Time
M. Chace No
Bryan M. CrabtreeREVIEWED BY:
Our reports are available in PDF form via email. Please email us at reports@utsofmass.com for more information.
cc:Fulcrum Associates Pat Madden
Fulcrum Associates Brad Scott
Fulcrum Associates Darrin Standish
DMS Design Sid Silveira
DMS Design Dan Skolski
City of Salem Steve Cummings
Veitas & Veitas Linas Dabrila
DSF Group Paul Bowie
DSF Group Benjamin Greene
Fulcrum Group Patricia Dwyer
UTS Matt Chace
DSF Flint Salem LLC Dimitri Kourtis
Fulcrum Associates Bob Levesque
DSF Advisors Thomas Mazza
UTS Jill Crabtree