Loading...
UTS Job 23418 Report 7 Compressive Strength Report - Mortar 11-11-2019 (002)-Page 1 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 11-11-2019Compressive Strength Report - Mortar Report No.7 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.On Site ALL FIELD TESTS DONE ACCORDING TO ASTM:C-1064 C-270 C-109ALL COMPRESSIVE STRENGTH TESTS DONE ACCORDING TO ASTM: CLASS MORTAR:Type S-1800#No. Of Sets:1 SET 1 LOCATION:Column lines; C at 3, Course 1 Total Unit Lab Size Area Date Date Age Load Load No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.) P639 2 x 2 x 2 4.00 Good 11/11/2019 11/18/2019 7 4,000 1,000 P640 2 x 2 x 2 4.00 Good 11/11/2019 12/09/2019 28 9,300 2,330 P641 2 x 2 x 2 4.00 Good 11/11/2019 12/09/2019 28 9,500 2,380 P642 2 x 2 x 2 4.00 Good 11/11/2019 12/09/2019 28 9,600 2,400 Air Temp. (F.)50 Mortar Temp (F)50 Time 1:00 Start Course 1, Building 2, Column lines C at 3 - C at 6GENERAL REMARKS: Inspector Premium Travel Name Time Hours Time Parke Sickler Jr.No Max Day 1 Hr(s) Bryan M. CrabtreeREVIEWED BY: Our reports are available in PDF form via email. Please email us at reports@utsofmass.com for more information. cc:Fulcrum Associates Pat Madden Fulcrum Associates Brad Scott Fulcrum Associates Darrin Standish DMS Design Sid Silveira DMS Design Dan Skolski City of Salem Steve Cummings Veitas & Veitas Linas Dabrila DSF Group Paul Bowie DSF Group Benjamin Greene Fulcrum Group Patricia Dwyer UTS Matt Chace DSF Flint Salem LLC Dimitri Kourtis Fulcrum Associates Bob Levesque DSF Advisors Thomas Mazza