Loading...
UTS Job 23418 Report 59 Compressive Strength Report - Concrete 11-20-2019-Page 1 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 11-20-2019Compressive Strength Report - Concrete Report No.59 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.J.G. MacLellan ALL FIELD TESTS DONE ACCORDING TO ASTM:C-172 C-31 C-143 C-1064 C-231 C-39 C-1231ALL COMPRESSIVE STRENGTH TESTS DONE ACCORDING TO ASTM: CLASS CONCRETE:4500# 3/4"No. Of Sets: 5 221.5CUBIC YARDS: SET 1 LOCATION:SOG; Column lines 14 at B Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type Q603 4.00 x 8.00 12.57 Good 11/20/19 11/27/19 7 60,000 4,770 5 Q604 4.00 x 8.00 12.57 Good 11/20/19 12/04/19 14 68,000 5,410 3 Q605 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 72,500 5,770 4 Q606 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 77,000 6,130 2 Q607 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 75,000 5,970 2 Slump (in.)* Air Temp. (F.)40 Conc Temp (F)63 Truck No.189 Ticket No.9126 Time 7:15 Unit Wt lbs/cu ft Air Content (%)6.2 SET 2 LOCATION:SOG; Column lines 18 at G Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type Q588 4.00 x 8.00 12.57 Good 11/20/19 11/27/19 7 60,000 4,770 5 Q589 4.00 x 8.00 12.57 Good 11/20/19 12/04/19 14 63,000 5,010 3 Q590 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 74,000 5,890 3 Q591 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 80,000 6,360 5 Q592 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 75,000 5,970 2 Slump (in.)6 Air Temp. (F.)40 Conc Temp (F)73 Truck No.238 Ticket No.4773 Time 7:35 Unit Wt lbs/cu ft Air Content (%)6.2 SET 3 LOCATION:SOG; Column lines 13 at E.1 Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type Q598 4.00 x 8.00 12.57 Good 11/20/19 11/27/19 7 53,500 4,260 5 Q599 4.00 x 8.00 12.57 Good 11/20/19 12/04/19 14 65,000 5,170 5 Q600 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 75,000 5,970 3 Q601 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 74,000 5,890 2 Q602 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 72,500 5,770 2 Slump (in.)6 3/4 Air Temp. (F.)40 Conc Temp (F)74 Truck No.2067 Ticket No.4786 Time 8:35 Unit Wt lbs/cu ft Air Content (%)5.1 SET 4 LOCATION:SOG; Column lines 11 at F Page 2 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 11-20-2019Compressive Strength Report - Concrete Report No.59 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.J.G. MacLellan Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type Q593 4.00 x 8.00 12.57 Good 11/20/19 11/27/19 7 47,500 3,780 2 Q594 4.00 x 8.00 12.57 Good 11/20/19 12/04/19 14 72,000 5,730 5 Q595 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 77,000 6,130 5 Q596 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 75,000 5,970 4 Q597 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 78,000 6,210 3 Slump (in.)6 Air Temp. (F.)40 Conc Temp (F)72 Truck No.257 Ticket No.4789 Time 9:25 Unit Wt lbs/cu ft Air Content (%)6.0 SET 5 LOCATION:SOG; Column lines 6 at F Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type Q628 4.00 x 8.00 12.57 Good 11/20/19 11/27/19 7 50,000 3,980 3 Q629 4.00 x 8.00 12.57 Good 11/20/19 12/04/19 14 60,000 4,770 3 Q630 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 70,000 5,570 2 Q631 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 72,000 5,730 4 Q632 4.00 x 8.00 12.57 Good 11/20/19 12/18/19 28 66,000 5,250 5 Slump (in.)6 3/4 Air Temp. (F.)40 Conc Temp (F)70 Truck No.187 Ticket No.164805 Time 11:20 Unit Wt lbs/cu ft Air Content (%) GENERAL REMARKS:Cylinders received on 11/22/2019. Inspector Premium Travel Name Time Hours Time William Fitzpatrick No Max Day 1 Hr(s) REVIEWED BY:Bryan M. Crabtree FRACTURE TYPES Type 1 Type 2 Type 3 Type 4 Type5 Type 6 Reasonably well-formed Well-formed cone on Columner vertical Diagonal fracture Side fractures at top Similar to Type 5 cones on both ends,one end, vertical cracks cracking through with no cracking or bottom (occur but end of less than 1 in.running through caps,both ends, no through ends; tap commonly with cylinder is [25 mm] of cracking no well-defined cone well-formed cones with hammer to unbonded caps)pointed Page 3 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 11-20-2019Compressive Strength Report - Concrete Report No.59 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.J.G. MacLellan throught caps on other end distinguish from Type 1 Our reports are available in PDF form via email. Please email us at reports@utsofmass.com for more information. cc:Fulcrum Associates Pat Madden Fulcrum Associates Brad Scott Fulcrum Associates Darrin Standish DMS Design Sid Silveira DMS Design Dan Skolski City of Salem Steve Cummings Veitas & Veitas Linas Dabrila DSF Group Paul Bowie DSF Group Benjamin Greene Fulcrum Group Patricia Dwyer UTS Matt Chace DSF Flint Salem LLC Dimitri Kourtis Fulcrum Associates Bob Levesque DSF Advisors Thomas Mazza UTS Jill Crabtree Page 4 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 11-20-2019Compressive Strength Report - Concrete Report No.59 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.J.G. MacLellan FIELD SUMMARY REPORT Total Pour:Slab on grade, column lines 6-20 at A-G.2 Method of Placement:Pump Chute Discharge Bucket OtherX Other: Vibrator OtherMethod of Concrete Consolidation:X Other: Cylinder Fabrication Location:Truck Discharge Chute End of Pump HoseX Cylinder Storage:Curing Box Thermal Blanket Hay/Straw Trailer FieldX Other Placement Protection:Thermal Blankets Heat NoneX Other Slump Specification (in.)4-6 Number of slumps out of specification reported to If rejected Approved by Remarks: UTS of Massachusetts, Inc. Page 5 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 11-20-2019 Report No.59 Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MAAttachment UTS of Massachusetts, Inc. Page 6 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 11-20-2019 Report No.59 Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MAAttachment