Loading...
SEPTIC INSTALLER - RALPH SIMMARD ov, ,. City Of Salem, Massachusetts Board of Health 120 Washington Street, 4th Floor, Salem, MA 01970 IPublicHealth Kimberley Driscoll TEL. (978) 741-1800 FAX. (978) 745-0343 Mayor Iramdin salem.com Larry Ramdin, MPH, REHS,CHO Health Agent GENERAL HEALTH PERMIT Permit# GHL-15-416 License For : Site Assessment Date of Print 12/15/2015 Granted To: Ralph Simmard Permit Issued 12/15/2015 Address: Box 436 North MA 01864 Reading Permit Expires 12/31/2016 Location of Establishment: SWAMPSCOTT ROAD Permit Fee $0.00 Restrictions: Septic Installers Permit Swampscott Road Late Fee $0.00 Notes: This permit or license is granted in conformity with the statues and ordinances relating thereto, and expires on 12/31/2016 , unless sooner revoked or suspended. �] CITY OF SALEM, MASSACHUSETTS BOARD OF H ALTH -- -- 120 WASHINGTON STREET,4"FLOOR PublicHealth Prevent.Promote.Protect. TEL. (978) 741-1800 FAX(978) 745-0343 KIMBERLEY DRISCOLL Iramdin e salcm.com L:ARKY 1L\MD1N,2S/R[:I-[S,CI{O,CP-FS MAYOR L (Z' HIJIM:r-I AGUNT Name: & Phgqne#: Address: /3 e,} y dr/-y/�Pyr/iP� a2f G/ Examination for License for Septic Work in Salem V/1. As you begin the job, you notice that something noted on the plan is not correct, or you have a question. You would: (pick two) Contact the engineer and health .agent immediate) g g Y b. You put in the calls to the engineer and health agent, but cannot reach them, so you begin the job and wait for them to call you back. G You stop the work until you can speak with the engineer and health agent. d. You call the DEP for an answer. ✓2. The slope of the distribution lines in beds and fields must be: (feet per foot) Ga .005 b. .050 c. .0005 d. .50 ✓3. Septic tanks may not be constructed of the following materials: a. Poured-in-place concrete. b. Precast reinforced concrete c. Fiberglass. Metal e. Polyethylene f. Other materials as approved in writing by the DEP. L4. In a septic tank the inlet pipe elevation shall be no less than 2 inches or more than 3 inches above the invert elevation of the outlet pipe. O true b. false 5. When a sewer system becomes available, any person owning a tight tank shall connect to the sewer within 30 days and the tight tank shall be properly abandoned. true false V16- A system is not considered failing if the static liquid level of the distribution box is above the level of the outlet invert. a. true O false /. The top of all system components shall be installed no less than 48 inches below finished grade. a. true G false V 8. The minimum distance required between a leaching facility and a private well is: a. 25 ft b. 50 ft c 75 It 100 ft 1 /9. A minimum of how much crushed stone is required beneath a septic tank? V a. 2 inches b. 4 inches Q6 inches d. 8 inches V/1 0. When garbage grinders are installed the leaching area must be increased by: a. 10% b. 15% c. 25% ® 50% /1 1. Alarms provided in pump systems can be connected to the same circuit used for pump(s). a. true false VII 2. Excess amount of fines on washed stone or replacement sand may contribute to the premature failure of a septic system. ® true b. false /13. Outlet pipes from the D-box are not required to be level the first two feet. ✓ PP q a. true 0 false /4. When a system has been pumped the local Board of Health is required to receive a copy of the pumping record. true b. false ✓15. If a septic system or cesspool requires pumping more than 4 times a year the system is considered failing. ✓w2_ aQ true b. false �,Xl 6. Regarding setback distances, pick the one incorrect distance. a. from property line to septic tank is 10 feet b. from bordering vegetative wetland to soil absorption system is 50 feet 9 from cellar wall to septic tank is 50 feet from a surface water supply (reservoir) to the septic tank or SAS is 400 feet. /7. The building sewer shall be sufficient to serve the connected fixtures. In no case hall the building sewer be less than four inches in diameter. true false ^� 18. Beds and fields can have how many distribution lines? / minimum number of distribution lines is two 6 one /9. (6 pts.) A plan provides a benchmark of 89.92 and you get a rod reading on the benchmark of 1.2 feet above the benchmark. Using the height of the level, what would your rod reading have to be if the plan shows the bed bottom elevation to be at 84.20? 20. (4 pts.) When constructing in fill, the toe of the slope shall be a minimum of /0 feet from any adjacent property line, or swale or other drainage system directing run- off away from the adjacent property shall be installed. Adjustments to the above side ma slopes be allowed if a suitable P a��j ✓� c m-7yTro,�s installed P Y to mitigate potential sewage breakout. 6- � gEADInC zo�,�4 �9tn s N �Qs� tiay' Town of North Reading 1713 Massachusetts . Board of Health MEMORANDUM To: Whom It May Concern From: Martin Fair, Health Agent Date: July 2, 2014 Subject: Ralph Simard, Disposal System Installer I am pleased to recommend Ralph Simard to be permitted as a Disposal System Installer by your Board of Health. Ralph has been installing systems in North Reading for twelve (12) years. He is well equipped; uses quality materials and his work is excellent. Ralph has been great to work with and I am sure you will enjoy working with him too. If you require any additional information, please feel free to call me at (978) 357-5242. 235 North Street, North Reading, MA 01864 ... 978/357-5242-FAX 978/664-1713 LJR Engineering, Inco Civil Engineers&Land Surveyors 1 234 Park Street North Reading,MA 01864 (978)664-8141 Fax(978)6648142 Email:iroy@lijrengineedng.com July 8,2014 RE: Simard Construction P.O. Box 436,North Reading,MA 01864 To Whom It May Concern: LJR Engineering, Inc. (previously O'Neill Assoicates)has been providing professional civil engineering and surveying services for over 20 years. During that time we have designed many subsurface septic disposal systems and sewer connections. We have over 10 years knowledge of Mr. Simard's experience as an installer of many of our designs in the Town of North Reading and surrounding communities. Through the As-Built process we have never had any issues with his installations. We found that he is very knowledgeable of Title 5 and highly recommend him as a septic disposal system installer or drainlayer. If you have any questions,please feel free to contact me at 978-664-8141. Sincerely, LJR Engineering,Inc. b0owi F Luke J. Roy, P.E. new England Interstate Water y Pollution Control Commission THE..COMMON�?k1v:.,EALTH OF MASSACHUSETTS DEPARTMENT OF ENVIRONMENTAL PROTECTION BE IT KNOWN THAT Ralph Simard Has satisfied the Department's qualifications as required and is hereby authorized to use the title CERTIFIED TITLE .6 SYSTEM INSPECTOR as provided in 310 CMR 15.340 and Section 13 of'Chapter 21A of the General Laws. Issued by The Department of Environmental Protection:' September 25,2008 Director $113015 ,� p.,,. ft � §.. A"+,1�.- •' _ tea- '� • si? E ,��'� � y,� -qg»,, S._�'- ,�, 'r _- ,p rt... w , t '[•� t .a s .,� r NUMBER;MASSACHUSETS " s`"'e r�,�1 „ o r A ".J _Px BHP-sola- oz TOWN'OF-LYNNFIELDn ' x ,-3 < 6Y �! s °" Board Of Health d Gr$ m • 4 x yp FEE - ° ��•.s t ; „� s1s F r 4 a: g ro $100.00 T �x +� r Ralph Simard for Simazd Construction —. ' y c DATE ISSUED �� v � .# �. t °e'rr NAME i H1Y January 0l 20158 0,90 Park St NORTH READING,-,MA ------------------ r READING, MA a N - -�- -- ................ --..- _ ADDRESS s ° a a v ° A IS-HEREBY GRANTED A Septic Installer * " „ '�° N t, ' Septic Installer' Z ` r, ' This permit is granted in conformity with the Statutes and ordinances relating thereto and k,- expires December 31 2015 unless sooner:suspended or revoked. r ate', a- ' "!i �.�r....•k' ' ,<-$ ° 1 4 '� Board of � �;•, ':; , �-,. x � ,, � � A .. -- - Health Lill n r rt • 4' L Septic Exam Answers 5 pts. Each 1. a, c 2. a 15.251(9) 3. d 15.226(1) 4. a 15.227(5) 5. a 15.260(5) 6. b 15.303 7. b 15.221(7) no more than 36" 8. d 15.211 9. c 15.228(1) 10. d 15.240(4) 11. b 15.231(9) 12. a 13. b 15.232(3) 14. a 15.351 15. a 15.303(1) 16. c 15.211 17. a 15.222(1) 18. a 15.252(2) 6 pts. 19. 6.92 (89.92+1.2) - 84.20= 6.92 4 pts. 20. 5 feet impervious layer (such as a retaining wall) 15.255(2) 100 Pts. total