CODE ANALYSIS @ 132-134 CANAL STREET Code Analysis for Canal Street North, Salem, MA June 14, 2019 Scope of Work/Renovation New Construction.First floor retail spaces,and apartment lobby and laundry. Second and third floor apartments. Elevator access provided. Applicable Codes: Building: 78o CMR, Massachusetts State Building Code 9th Edition (2015 IBC,with Massachusetts amendments) Energy Conservation: 2015 International Energy Conservation Code with Massachusetts Stretch Energy amendments Fire Prevention: 527 CMR Massachusetts Fire Prevention Regulations Accessibility: 521 CMR, Massachusetts Architectural Access Board Regulations&Americans with Disabilities Act(ADA), Fair Housing Act. Electrical: 527 CMR 12.00 Massachusetts Electrical Code Mechanical: 2015 International Mechanical Code,with Massachusetts amendments Plumbing: 248 CMR,the Fuel Gas and Plumbing Code Occupancy Classification: M (Mercantile), R2(Apartments) Occupancy Separations Table 508.4: 1-hour(sprinklered). Minimum Construction Type: VB Height and Area Limitations: Mixed-Use Table 504.3: Occupancies M, R2 6o'allowed(sprinklered-S), 40'-o"+/-actual—complies Table 504.4: M occupancy: 2 stories allowed(sprinklered-S) Actual height:1 story-complies R2 occupancy:3 stories allowed(sprinklered-S) Actual height:3 story-complies Table 506.2: M occupancy: 27,00o sf allowed(sprinklered-SM) R2 occupancy: 21,000 sf allowed(sprinklered-SM) Actual:9,957 sf-complies Occupancy Separations: Table 508.4: R2-M sprinklered: 1 hour separation required Minimum Construction Type:Type VB assumed Fire Resistance Ratings: Bldg Element Rating(Hrs) Opening (Table 601) Protectives(Mins) Structural Frame o Interior Bearing Walls o 20 Int. Non-Bearing Walls o Floor construction o Roof construction o Interior Finishes: Bldg Element Class Table 8o3.i3. Rooms, enclosed spaces C Interior exits, passageways: C(note b applies) Corridors,exit access stairs: C Means of Egress: Egress capacity(Chapter io): Floor Area: Use Group Load Factor(Table ioo4.1.2) Occupants No.of Exits 8,238 M(Mercantile) 6o gsf/occupant 138 2 req'd,io provided 9,957 R-2(Res.) zoo gsf/occupant 5o 2 req'd, 2 provided Exit Access Travel Distance(Table 1017.2) Use Group Max.Travel Distance Measured Travel Distance M 25o ft.(sprinklered) 46 ft.Complies R-2 250 ft.(sprinklered) 42 ft.Complies Fire Protection Systems: Group M: Manual Fire Alarm Systems: Not required based on 907.2.7 Fire Sprinkler System: Not required based on 903.2.7(sprinkler system provided)* Fire Extinguishers:Required based on Section gob. *Fire sprinkler system is required for entire building per Group R2 requirements. Group R-2: Manual Fire Alarm Systems: Required based on go7.2.9.1 Fire Sprinkler System: Required based on 9o3.2.8 Fire Extinguishers: Required based on Section 906. C:\Users\john\Dropbox\projects\2018-11-SA-canal street\02-design\Code_Analysis_for_Canal Street North.docx