Loading...
UTS Job 23300 Report 2 Compressive Strength Report - Concrete 09-23-2019 (003)-Page 1 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 09-23-2019Compressive Strength Report - Concrete Report No.2 Distribution Copy Job Number 23300 Project South Residential,124 Ocean Ave,Salem,MA Contractor Symes Associates Concrete Co.J.G. MacLellan ALL FIELD TESTS DONE ACCORDING TO ASTM:C-172 C-31 C-143 C-1064 C-39 C-1231ALL COMPRESSIVE STRENGTH TESTS DONE ACCORDING TO ASTM: CLASS CONCRETE:3000# 3/4"No. Of Sets:1 20CUBIC YARDS: SET 1 LOCATION:Footing; Column lines A.8 - F Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type T677 4.00 x 8.00 12.57 Good 09/23/19 09/30/19 7 27,500 2,190 5 T678 4.00 x 8.00 12.57 Good 09/23/19 10/07/19 14 35,000 2,780 3 T679 4.00 x 8.00 12.57 Good 09/23/19 10/21/19 28 39,000 3,100 4 T680 4.00 x 8.00 12.57 Good 09/23/19 10/21/19 28 43,000 3,420 3 T681 4.00 x 8.00 12.57 Good 09/23/19 10/21/19 28 42,000 3,340 3 Slump (in.)5 Air Temp. (F.)85 Conc Temp (F)82 Truck No.0184 Ticket No.7466 Time 2:00 Unit Wt lbs/cu ft Air Content (%) GENERAL REMARKS:Cylinders received on 09/24/19. Same Day Call In. Inspector Premium Travel Name Time Hours Time Conner Welch No Min Day 1 Hr(s) REVIEWED BY:Bryan M. Crabtree FRACTURE TYPES Type 1 Type 2 Type 3 Type 4 Type5 Type 6 Reasonably well-formed Well-formed cone on Columner vertical Diagonal fracture Side fractures at top Similar to Type 5 cones on both ends,one end, vertical cracks cracking through with no cracking or bottom (occur but end of less than 1 in.running through caps,both ends, no through ends; tap commonly with cylinder is [25 mm] of cracking no well-defined cone well-formed cones with hammer to unbonded caps)pointed throught caps on other end distinguish from Type 1 Our reports are available in PDF form via email. Please email us at reports@utsofmass.com for more information. Page 2 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 09-23-2019Compressive Strength Report - Concrete Report No.2 Distribution Copy Job Number 23300 Project South Residential,124 Ocean Ave,Salem,MA Contractor Symes Associates Concrete Co.J.G. MacLellan cc:Symes Associates, Mark Livesey Seger Architects Dan Ricciarelli McBrie, LLC Michael Perham McBrie, LLC Laura M. Bates City of Salem Steve Cummings Meninno Construction Tom Pascuccio Page 3 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 09-23-2019Compressive Strength Report - Concrete Report No.2 Distribution Copy Job Number 23300 Project South Residential,124 Ocean Ave,Salem,MA Contractor Symes Associates Concrete Co.J.G. MacLellan FIELD SUMMARY REPORT Total Pour:Column lines A.8 - F Method of Placement:Pump Chute Discharge Bucket OtherX Other: Vibrator OtherMethod of Concrete Consolidation:X Other: Cylinder Fabrication Location:Truck Discharge Chute End of Pump HoseX Cylinder Storage:Curing Box Thermal Blanket Hay/Straw Trailer FieldX Other Placement Protection:Thermal Blankets Heat None Other Slump Specification (in.)4-7 Number of slumps out of specification reported to If rejected Approved by Remarks: UTS of Massachusetts, Inc. Page 4 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 09-23-2019 Report No.2 Job Number 23300 Project South Residential,124 Ocean Ave,Salem, Attachment