Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
4 WEST TERRACE - BUILDING INSPECTION (2)
The Commonwealth of Massachusetts n Board of Building Regulations and Standards CITY OF 1 Massachusetts State Building Code,780 CMR a SALEM 0— Building Permit Application To Construct,Repair,Renovate Or ohsh a One-or Two-Family Dwelling Thio Section For Official Use Only I Building Permit Number: Date Applied: t8 1 Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&P el Numbers 4 West Terrace I Lla Is this an accepted sheet?yes_ no_ Map Number Parcel Number 13 Zoning Information: 1.4 Property Dimensio Zoning District Proposed Use Lot Area(sq 11) Frontage(R) 1.5 Building Setbacks(ft) Front Yard Side Yards j Rear Yard Required Provided Required Provided I equired Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ zone: _ Outside Flood Zone? Muni ipal O On site disposal system ❑ Check if yrs❑ SECTION 2: PROPERTY OWNERSHW 2.1 Owner'of Record: Joseph Ivlorency Salem MA 01970 Name(Print) - City,State,ZIP 4 West Terrace 97817744-8288 No.and Sueet Wephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORle(check all that apply) New Construction❑ Existing Building❑ Owner-occupied ❑ 1 Repairs(s) O 11 Alteration(s) M Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Unitst Other ❑ pmify: Brief Description of Proposed Work: Installation of a 3.92 kw 12panels) rooftop solar arra SECTION 4:ESTIMATED CONSTRUCTION CO STS Item Estimated Com' Official Use Only (Labor and Materials 1.Building $ 7,000 1. Building Permit Fee:$ Indicate how fee is determined: ❑Standard City/Town Applim ion Fee 2.Electrical $ 14,534 ❑Total Pi ject Cost(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechantcal (Fite $ Suppression) Total All Fees:$ 6.Total Project Cost: $ 21,534 Check No._Check Amo t: Cash Amount:_ O Paid in Eull E3Balance Due: SECTIONS: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 096385 10/8/2016 Romain Strecker License Number Expiration Dau Name of CSL Holder U List CSL Type(see below) 55 Sixth RoadType Description No.and Street Woburn MA 01801 U Umes 'clod(Buildings to 35,000 cu.R) R Restri l&2 Family Dwelling City/Town,State,zip M Meso RC go, no Emoting WS Window and Siding SF Solid=I Burning Appliances 781-462-8702 permits0ostonsolar.us I Inco latioa Telephone Email address D Demolition 51 Registered Home Improvement Contractor(HIC) 169698 7/27/2015 Boston Solar/Romain Strecker HICRegis�tLon Number Expiration Date - BIC Campauy Name m BIC Registreat Name 55 Sixth Road _per .itsobostonsolar.us No.and Street Email address Woburn MA 01801 781-462-8702 Ci /Town,State ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFPIDA (M.G.L.c.152.§ 25C(6)); Workers Compensation Insurance affidavit must be completed and submitted with 's application. Failure to provide this affidavit will result in the denial of die Issuance of the building permit. Signed Affidavit Attached? Yes..........® No...........C .SECTION 7s:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Las Owner of the subject property,hereby authorize Romain Strecker to act on my behalf,in all matters relative to work authorized by this building permi.application. Joseph Morencv 12/16/2015 Print Owners N me(Ele tr nic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DEI TION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Romain Strecker 12/16/2015 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do hislher own work,or an ownery rho hires an unregistered contractor (not registered in the Home improvement Contractor(EIC)Program),will nor I lave access to the arbitration program or guaranty fund under M.G.L.c.142A.Other important information n the HIC Program can be found at www.ma Lgov/oca Information on the Contraction Supervisor License can be found at www.mass.aov/dos 2. When substantial work is planned,provide the information below: Total floor area(sq.R) (including garage,finished asement/attics,decks or porch) Gross living area(sq.ft.) Habitable room Fount Number of fireplaces Number of bedrpoms Number of bathrooms Number of half/paths Type of heating system Number of decW porches Type of cooling system - Enclosed .Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" 1 I S ,. CITY OF SALEM, N kssAcHusETrs BL'UMMIG DEP. MWNT 130 WASHI N=N STREET,3"PLOOR TEL(978)749595 FAR(978)7 -9846 10MBERIBY DRISCOLL 1bfAY01t THOMAS ST.PIEiuts D.UMMR OF PUBLIC PROPEMY� BUMDING COMMISM021M t Construction Debris Disposal Affidavit (required for all demolition and renova 'on work) In accordance with the sixth edition of the State Buildin C c 780 CMR section 111.5 Debris,and the provisions of MGL c 40,S 54; 8 Building Permit# is issued with the condi ion that the debris resulting from this work shall be disposed of in a properly licensed waste disposal facility as defined by MGL c 111,S 150A. The debris will be transported by: Boston Solar (name of hauler) The debris will be disposed of in: Boston Solar (name of facility) 55 Sixth Road Woburn MA (address of facility) i isignature o4ermit applicant 12/16/201 [late debrimlidoe /+7Lr`t�.................A/ Office of Consumer Affairs&Business Regulation License or registration valid for individul use only 3- HOME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Registration: 169698 Type: Office of Consumer Affairs and Business Regulation Expiration: 727/2017 LLC 10 Park Plaza-Suite 5170 a� Boston,MA 02116 THE BOSTON SOLAR COMPANY LLC ROMAIN STRECKER 55 SIXTH ROAD WOBURN.MA 01801 Underseeretary4 Not valid without signature Massachusetts -Department of Public Safety Board of Building Regulations and Standards Cfimtruction Supen icor License: CS-096385 ROMAIN D STREeKER ' 10 CHURCHILL kLA73E� LYNN MAO 1902 Expiration Commissioner 10/08/2016 �\ The Commonwealth of Massachusetts Department of Industrial Accidents I Congress Street,Suite 100 Boston,MA 02114-2017 www massgov/dia U,krkers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Leeibly Name(Businessiorganizationnndividual):The Boston Solar Company Address:55 Sixth.Road City/State/Zip:Woburn MA 01801 Phone#:617-858-1645 Are you an employer?Check the appropriate box: Type of project(required): I.O 1 am a employ"with 20 employees(Poll andlor pan-time).* 7. ❑New construction 2[]1 am a sole proprietor or partnership and have no employees working for me in 8. ❑Remodeling any capacity.[No wmkcn'comp.insurance required.] 9. 0Demolition 3.E]1 am a homeowner doing all work myself.[No workers'comp.insurance required.]! 10 Building addition 4.n 1 acct a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole I LQ Electrical repairs or additions proprietors with no employees. 12.[]Plumbing repairs or additions 5.❑1 am a general contractor and 1 have hired the sub-conmetors listed on the attached sheet. 13.[]Roof repairs These sub-contractors have employees and have workers'comp.insurance.* 14.Q Other SOlaf 6Q we are a corporation and its officers have exercised Meir right of exemption per MGL c. 152,§I(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 most also fill out the section below showing their workers'compensation policy information. ?Homeowners who submit this affidavit indicating they we doing all work and then hive outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional shat showing the name of the subcontractors and soon,whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that Is providing workers'compensation insurance for my employees. Below Is rhe policy and job site Information. Insurance Company Name:HDI-Gerling America Insurance Company Policy#or Self-ins.Lic.#:EWGCC000153815 Expiration Date:1/14/2016 Job Site Address: 4 West Terrace City/State/zip: Salem MA 01970 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pain n !ties ofperjury that the information provided above is true and correct Signature: Date: 12/15/2015 Phone#,617-858-1645 Oficial use only. Do not write In this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector S.Plumbing Inspector 6.Other Contact Person: - Phone#: Client#:103109 BOSSO ACORD. CERTIFICATE OF LIABILITY INSURANCE DATIYYYY) 1!1113/203/20D15 THIS CERTIFICATE IS ISSUED ASA MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder Is an ADDITIONAL INSURED,the policy(les)must be endorsed.If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not Confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME Peggy J.Merati People's United Ins.Agency CT (52,M 860 524-7624 No:844 702 8075 ARIL Ext: One Goodwin Square ADD RLu, peggy.merati@peoples.com Hartford,CT 06103 INSURERS AFFORDING COVERAGE NAICIf 860 524.7600 INSURER A,HDI-Gerling America Insurance C 41343 INSURED INSURERS,Merchants Mutual Insurance CO 23329 The Boston Solar Company, LLC INSURERC: 55 Sixth Road,Suite 1 INSURER D Woburn,MA 01801 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. R TYPE OF INSURANCE ADD B POLICY NUMBER MMND EFF MMIDOY EXP LIMITS LTRA GENERAL LIABILITY EGGCC000153814 0/03/2014 0110112016 EACH OCCURRENCE $1000000 X COMMERCIAL GENERAL LIABILITY PREMIA ' EaEo�au�rtenco $100000 CLAIMS-MADE OCCUR MED EXP JArvy one person) $ PERSONAL&ADV INJURY $1.000.000 GENERAL AGGREGATE s2,000,000 GEN'LAGGREGATE LIMIT APPLIES PER: PRODUCTS-COMPIOPAGG s2000,000 POLICY X PRO- LOC $ /A AUTOMOBILE LIABILITY EAGCC000153814 0/03/2014 01/01/201 Ea=ddEentAINGLEUMiT 1,000,000 A X ANY AUTO EAGCC000153914 0/03/2014 01/01/2016 BODILY INJURY(Par person) $ ALL OWNED SCHEDULED BODILY INJURY IPer accded) s AUTOS AUTOS O ON X HIRED AUTOS X ANUTOSSW"ED Per.oddenif $ $ B X UMBRELLA LIARX OCCUR CUP0001367 0/03/2014 01/01/2016 EAcHoccuRRENcE s5000000 EXCESS UAB CLAIMS-MADE AGGREGATE $5,000,000 DED I X1 RETENTION$10,000 1 1$ A WORKERS COMPENSATION EWGCC000153815 1114/2015 01114/201C X We sTATu- DTH. AND EMPLOYERS'LIABILITY ANY PROPRIETORIPARTNER/EXECUTIVE Y I N E.L.EACH ACCIDENT $1 OOO OOO OFFICERRAEMBEREXCLUDEDT � NIA (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $1000000 If yes,describe under E.L DISEASE-POLICY LIMIT DESCRIPTION OF OPERATIONS bdow-F DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(Attach ACORD 101,AddlUonal Remarks So adule,It mora apace is".1red) RE:Permit Work Certificate Holder is included as Additional Insured per the terms,conditions and exclusions of the referenced general liability and umbrella policies,if required by written contract or agreement. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 120 Washington Street,3rd Floor ACCORDANCE WITH THE POLICY PROVISIONS. Salem,MA 01970 AUTHORIZED REPRESENTATIVE rr rra L)A*dj�j 4d14A& ©1988-2010 ACORD CORPORATION.All rights reserved. ACORD 25(2010/05) 1 of 1 The ACORD name and logo are registered marks of ACORD OS565550IM565467 SMGCT BOSTON SOLAR Solar System Purchase and Installation Agreement Overview Installer Owner The Boston Solar Company,LLC Joe Morency 55 S'lxth Rd 4 West Terrace Woburn,MA 01801 Salem,MA,01970 Major Components System Size: Sunpower E20-327 12 3.92 kW Inverter Solaredge 3.8 RGM Estimated Year 1 Production Production Monitoring Automated 4,692 kWh - Total System Cost $21,533.45 Payment Schedule: Federal Tax Credit $6,460.03 At Signing $6,460.03 State Tax Credit $1,000.00 At Installation $12,920.07 MA Solar or Utility Rebate At System Commissioning $2,153.34 Final System Cost $14,073.41 Total of Payments: $21,533.45 Payment Type: CASH These financial estimates are provided for illustrative purposes.For actual financial and tax advice,please consult an independent tax advisor. Overview. As part of this Agreement,The Boston Solar Company will: • Handle all aspects of the project from Initial paperwork through to installation and activation of your Solar System •Secure State or Utility rebates(if applicable),permits,and utility interconnection approval •Install revenue grade monitoring,giving you real time insight into your system's performance,and allowing you enjoy automatic production reporting to generate your SRECs(Owner is required to have secure and stable Internet connection on the Property) •Set up your brokerage account with SRECTrade,the largest SREC aggregator,who will sell your SRECs and pay you quarterly(starting approximately six months after your system is activated) • Provide you with all related manufacturer warranties 77me for Completion: It is expected that installation will be completed within 90 days after contract signing.The actual Installation is expected to take 2-3 days.Once installation is completed,the Owner will need to make the Property available for electrical and building inspections within two weeks after installation.After inspections,the utility is expected to give us final approval to tum on the system within 2-4 weeks.The entire process from contract signing to system commissioning is expected to take 4 months,but may take longer depending on town and utility approvals,weather and equipment availability. Addltiond Contact ProvWmm All payments are due immediately upon completion of each stage of the project Quoted system price includes permit costs and utility interconnection fees.This Solar System Includes a 10-year labor warranty,25-year Inverter warranty and 25-year panel power warranty. Agreement This Attachment forms partof the Solar Purchase and Installation Agreement Boston Solar Representative Signature:10�� Date: / Owners signature: Date: / 2/.3/EIS Co-Owners Signature: Date: --BBST6N SOLAR SOLAR SYSTEM PURCHASE AND INSTALLATION AGREEMENT O`w.) �05�' n��\ � �� \ (the"Owner ) Site Address: c Sri )e (the"Property") Date_; A�� � � This Solar System Purchase and Installation Agreement("Agreement") is entered into effect as of the latest date of signature of the parties below by and between The Boston Solar Company LLC,5S Sixth Rd, Woburn, MA 01801( TBSC")and the Owner,who is the owner of the Property.All capitalized terms used in this Agreement but not defined herein shall have the meanings set forth in The Boston Solar Company Proposal attached hereto(the"Attachment"). 1. THE WORK TBSC shall perform work,provide the Services,supply such Equipment and furnish such other materials, supplies and other items as it determines are required to install the System described in the Attachment(the "Work").TBSC will perform or cause Its subcontractors to perform the Work in a good and workmanlike manner,in accordance with prudent industry standards and practices.TBSC shall not make any changes in the Work unless agreed to in writing by the Owner. 2. REQUIRED PERMITS TBSC shall be responsible for acting as the Owner's agent to secure any permits required for the installation. All permit costs are Included in the price for the Work. If you secure your own permits,you will be excluded from the Guaranty Fund provisions of Chapter 142A of the Massachusetts General Laws. 3. WARRANTIES TBSC warrants that,under normal use and service conditions,the System will be free from defects in workmanship and/or materials for ten(10)years after the date of the Work being completed(this"Limited Warranty").This Limited Warranty includes servicing manufacturer warranties free of charge.TBSC warrants any damage to Owner's roof within a five(5)Inch radius of roof penetrations during performance of the Work. If a defect is discovered,TBSC will,at no additional cost to Owner,provide such labor and materials as required to restore the System to its originally Installed state.If TBSC finds that the problems were not caused by the Work,or if the problems are not an actual problem of the System(e.g.shade or unauthorized alterations to the System),Owner will pay for any new parts and materials,and TBSC reserves the right to charge Owner a service charge of$100 per hour with the minimum service charge equal to$200. 1 i BOST,ON SOLAR SOLAR SYSTEM PURCHASE AND INSTALLATION AGREEMENT Effective immediately upon Owner making the final payment under this Agreement,TBSC hereby assigns to Owner,to the extent assignable,any and all manufacturer warranties covering the Equipment and shall deliver copies of such warranties after Its receipt of such final payment. 4. TIME FOR PERFORMANCE TBSC shall perform the Work diligently,without unnecessary delays or interruptions and in a timely manner until completed.TBSC shall use reasonable efforts to start and complete the Work according to the timing described in the Attachment. 5. INSURANCE AND LICENSING TBSC represents and warrants to the Owner that TBSC or any subcontractors performing the Work shall be licensed and hold insurance coverage as required by applicable laws. TBSC is registered as a Home Improvement Contractor with the Massachusetts Office of Consumer Affairs and Business Regulation,under registration#169698. 6. OWNER CANCELLATION RIGHTS If Owner delivers a completed Notice of Cancellation within three(3)business days after the date of this Agreement,TBSC shall refund and return the Deposit in full to the Owner within ten(10)business days after its receipt of such Notice of Cancellation(attach to this Agreement). Owner acknowledges that TBSC will spend time and money evaluating the Property,designing the System and preparing the Work.If Owner cancels this Agreement after ten(30)business days,a cancellation fee of $1,000 will be deducted from the Deposit.Any permit costs and unrecoverable equipment costs Incurred by TBSC will be added to the cancellation fee and deducted from the Deposit. 7. TAX CREDITS,REBATES AND SRECS The Owner may be entitled to certain financial benefits related to the ownership and use of the System, including state or utility rebates("Rebates"),solar renewable energy certificates("SRECs"),state and federal income tax credits and net metering credits("Net Metering")(collectively defined as"Benefits").TBSC shall prepare,process and submit applications on behalf of Owner for Rebates,SRECs and Net Metering.TBSC Is acting purely as an administrative agent and cannot guarantee the outcome of such applications. The Attachment Includes an estimate of the Benefits that may be available to the Owner.TBSC makes no representation or warranty with respect to the Owner's eligibility to receive such Benefits.In all cases,Owner agrees to consult with the relevant governmental officials and Owner's accountant when evaluating Owner's eligibility for and the financial and tax consequences of receiving Benefits. 2 BOSTON SOLAR SOLAR SYSTEM PURCHASE AND INSTALLATION AGREEMENT S. PRE-EXISTING CONDITIONS AND PROPERTY PROTECTION TBSC shall not be responsible for any damages as a consequence of the Work performed on the site due to pre-existing conditions(e.g.cracked or broken shingles,faulty electrical wiring,etc.) TBSC reserves the right to suspend performance of the Work or terminate this Agreement with no liability to TBSC whatsoever if it discovers unanticipated site conditions that will increase the cost to perform the Work. If such termination occurs,TBSC shall refund all monies paid to TBSC reduced by any expenses actually Incurred.However,if Owner and TBSC agree,the price may be renegotiated to reflect the true cost of the Work. TBSC will make best efforts to protect any property of the Owner,but the Owner is responsible for removing and replacing appliances,floor coverings,and any other obstacles or hazards required to perform the Installation.TBSC is not responsible for replacement of or damage to these items if they are removed by TBSC. 9. CUSTOMER OBLIGATIONS Owner agrees to:(a)notify TBSC immediately upon discovery of an emergency condition relating to the System,damage to the System,or theft of the System;(b)only have the System repaired pursuant to the Limited Warranty(as defined herein);(d)not modify the Property in a way that shades the System;(e)not do anything,permit or allow to exist any condition or circumstance at the Property which would cause the System not to operate as intended;and(g)permit TBSC,after providing reasonable notice,to inspect the System for proper operation,and to make any necessary repairs.Customer agrees to not make any modifications,improvements,revisions or additions to the System or take any other action that could void the Limited Warranty(as defined herein)without TBSCs prior written consent.If Owner fails to comply with the provisions of this paragraph,Owners Limited Warranty shall be automatically voided. 10. GENERAL PROVISIONS Any disputes which may arise between the Owner and TBSC shall not Impede or interfere with the diligent performance by TBSC of the Work.This Agreement shall be subject to and interpreted in accordance with the laws of the State of Massachusetts. Title,ownership and risk of loss to the System shall pass to Owner immediately upon Owners payment of the final payment required under this Agreement.Owner shall provide all insurance necessary for the coverage of the System and risks to the Property related thereto after such payment. 3 BOSTON SOLAR SOLAR SYSTEM PURCHASE AND INSTALLATION AGREEMENT This Agreement,including the documents Incorporated into this Agreement,forms the complete integrated agreement between TBSC and the Owner.The parties represent and warrant that in executing this Agreement,they are not relying on representations other than as expressly contained herein.There are no other terms or conditions that form a binding agreement between the parties other than this Agreement and its incorporated documents.This Agreement supersedes all prior agreements between the Owner and TBSC and may not be altered absent a subsequent written agreement signed by both parties.Both parties have reviewed this Agreement and represent that they understand and agree to the terms herein. //// �Owner's Signature. �f� Co-Owner's Signature: OwnersName: Co-Owner's Name: Date: 12 iu Date: �//� LTBSC A' uthorized Representative Signature; r�_. -� LTBSCAuthorized Representative Name: . . `"�,�t .. I"�a; \tom 1,e D,�te 9 t� i 4 BG&TGN SOLAR Homeowner's Agent Authorization Form Morey I, � --t- l(Print Name1; am the owner of the property located at address: ttPdni Ailare's:) I hereby authorized The Boston Solar Company to act as my Agent for the limited purpose of applying for obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. Print Nam �uSC?P~ / (cTe• iL y Customer5ignature: Date: The Boston Solar Company ' 55 Sixth Road Woburn,MA 01801 BostonSolacus (617)858-1645 UTAH OFFICES E CTO R Sandy Layton E n G I n E E R S St. George Project Number: U1876-0058-151 December 17,2015 Boston Solar 55 Sixth Road Wobum,MA 01801 ATTENTION: Race Traver REFERENCE: Joe Morency Residence:4 West Terrace,Salem,MA 01970 Solar Panel Installation Dear Mr.Traver: Per your request, we have reviewed the layout and photos relating to the installation of solar panels at the above- referenced site.The following materials and components are proposed in the installation of the solar panels. Roof Structure:2x6 Rafters @ 20"O.C. Roof Material:Composite Shingles Solar Panels:SPWR E20-327 Rail Connection System:Invisimount Mounting Connections:5/16'Diameter Lag Bolt with 2.25'Embedment,Minimum Based upon our review, it is our conclusion that the installation of solar panels on this existing roof will require new 2x6 rafters to be attached to the existing 2x6 rafters with 16d nails staggered at 8" O.C. The design of solar panel supporting members is by the manufacturer and/or installer. The adopted building code in this jurisdiction is the 2009 International Residential Code and ASCE 7-05. Appropriate design parameters which must be used in the design of the supporting members and connections are listed below: Ground snow load:40 psf per Massachusetts amendments to the IRC(verify with local building department) Design wind speed for risk category II structures: 100 mph(3-sec gust) Wind exposure:Category C Our conclusion regarding the adequacy of the existing roof with the proposed retrofit is based on the attached calculations. Regarding snow loads, it is our conclusion that since the panels are slippery and sloped, effective snow loads will be reduced in the areas of the panels.The attached calculations verify the capacity of the connections against wind, the governing load case. Solar panels will be flush-mounted, parallel to and no more than 6" above the roof surface. Thus, it is our conclusion that any additional wind or seismic loadings related to the addition of these solar panels is negligible. During design and installation,particular attention must be paid to the maximum allowable spacing of attachments and the location of solar panels relative to roof edges. The use of solar panel support span tables provided by the manufacturer is allowed only where the building type, site conditions, and solar panel configuration match the description of the span tables.Attachments to existing roofjoist or rafters must be staggered so as not to over load any existing structural member. Waterproofing around the roof penetration is the responsibility of others. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. Vector Structural Engineering assumes no responsibility for improper installation of the solar panels. Please note a representative of Vector Stmctural Engineering has not physically observed the roof framing. Our conclusions are based upon the assumption that all structural roof components and other supporting elements are in good condition,free of damage and deterioration,and are sized and spaced such that they can resist standard roof loads. Very truly yours, VECTOR STRUCTURAL ENGINEERING,LLC �y(HOF ROGER T. At IVI Roger T.Alworth,P.E. 0 Principal / RTA/mbtDBC. 17, 2015 9138 S. State St., Suite 101 /Sandy, UT84070/T(801)990-1775/F(801)990-1776/www.vectorse.com F. F— E. E O T O R [24F-W GRADES (psi) (psi) (psi) y(Ib/ft') JOB NO.: U1876-0058.151 DFu1 t.000 tea t7o0,000 32 E n G I rl E E R 9 DFL02 850 170 1,60e00a 32 DF l SX5 8 URGER 1350 170 1800,000 32 24F-V4 2.400 240 1800,000 32 PROJECT: Joe Momncy SUBJECT: BEAMS 24F-Ve 2400 240 1,800,00o 40 LVL 1,9X1 2,600 285 1,900,000 40 LVL(2on LVL(2.0X1o6E) I 2p200I 285 2.000,000 42 UMGN LOADS: Load Types:SmW is Live Dead LSL L&(18X1D6E) 1.700 400 1,300,000 42 Roo/ `22- 20 7 CRITERIA(1-1 a.1, dLL aDL PSL ML(20MME) zso0 290 1,3ao.ao0 42 ls=1.00 Floor ' i •YBLANK) 240 360 ants GRFDE3667EEL 21,600 14,400 29.1100.000 490 Wall I B 240 480 1 STLd6 OWE 4661EEL 21,60a 10.400 28,000.00D 490 AM Da to ased load I =•2`Sos C600 800 aTL50 GWESOa7EEl 30800 20,000 29.000.000 490 note:'a'must be less than or equal to'L/2' Point Point ALL Duane. Add'I Add'I A Live Dead - o (in) (in) Roof Floor Wall Live Dead Point ' Dist Load Load a 3 A (SEE (SEE 1.SDL Length Trib Trib Trib Load Load Load > 'a' 'PLC 'PDC m xo m M,,,m, (R Md,„. Vs,,, oTL d,La>. COND COND GLB Label Vitt) (ft) (R) (R) (plQ (pill From a (R) (lb) (lb) m Grade Size �_ p C, CD C, R,(ib) Re(Ib) Ib) (ft-Ib) V„ (lb) (lb) (in) (in) 'C') 'C') Camb Check 13.33 1,67 4.417 2 DFLM2 2x6 1.00 1.00 1.30 371 371 1235 13931 345 1870 0.594 0.667 0.356 0.444 0.89 D N:12015 Pmlectswi 6 Boston solantmo7 0056151 Joe Moreney=EM1 Y Y cy E C T O R JOB NO.: 0187 151 DESIGNED: MBT DATE: 12/17/15/17/15 E n G I n E E R 8 PROJECT: Joe Morency SUBJECT: Enclosure Calculations Com onents and Cladding Wind Calculations Label: L lar Panel (Unit Area), Note: Calculations per ASCE 7-05 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed[mph]: 100 Notes: Exposure Category: C Used 16 sf for effective wind area. ADDITIONAL INPUT&CALCULATIONS: Height of roof, h[ft]: 20� Comp/Cladding Location: Gable/Hip Roofs 7°5 B s 27° Enclosure Classification: Open Buildings 7 GCP:=Figure 6-11C (enter largest abs. value) a: 9.5 Table 6-2 zg[ft]: 900 Table 6-2 Kh: 0.902 Table 6-3 Kj: Figure 6-4 (leave blank for negligible topographic effects) K2:F-1 Figure 6-4 (leave blank for negligible topographic effects) K3: Figure 6-4 (leave blank for negligible topographic effects) K,: 1 Equation 6-3 K,: 0.85 Table 6-4 Velocity Pressure, qh[psf]: 19.63 Equation 6-15 GCp;: 0 Figure 6-5 (largest abs. value) OUTPUT: Design Pressure, p[psf]: 31.40 psf(1.OW) P=9a GCP – GCP,. E C TO R JOB NO.: U1876-0058-151 DESIGNED: MBT DATE: 12/17/15 E M O I n E E R S PROJECT: Joe Morency SUBJECT: CONNECTION CAPACITY Lag Screw Connection Capacity: Demand: Lag Screw Size:E2.25 Wind Pressure: 31.40 psf Cd: Tributary Area: 16 sf Embedment: in Demand: 502 lbs Capacity: lbs/in.emb. Number of Screws: Total Capacity: 738 lbs Demand<Capacity: CONNECf10N OKAY Project Data Codes MA CMR 79051.00 IBC-2009,ASCE 7.05 2005 NDS,NEC-2014 Inverter: SolarEdge3900A-US RGM W Panel: (12)SunPcmer 2D 27 Racking: InAsimount-Flush To Roof System Rating: 3.92 kW DC-STC - 1st Year Production:4,744 kWh Design Factors Ground Snow Load 40psf Wind Speed 100mph Utldty Meter \�4 V Utility Disconnect 1 k 11 V Inverter i I I I 1 1 1 a Bi�SW_^SSt _ Y KI / 3'Setback Roof 1 Azimuth: 143°N Tilt:32° Shade: 14% 12 Panels-1.209r 0 1 BOSTON SOLAR w.x,boewnaoar.w I into®emmnsoar.m Drmiig Name Site Plan Date September l],2015 CLIENT INFORMATION: Drawn by BG Joe Morency Checked 4 West Terrace REVp 00 Salem, MA 01970 PV - 2.0 (978)744-8288 Scale , As Note e olar Module Structure Module Sons Array Ce ie,00m Rol wor. Structure Type: Rafter Model: SPWR E20-327 Number of Modules: 12 Rafter Size: 2s'8' Length: 61.4" Total Module Weight: 502.68 Lbs OrRafter Spacing: 20' Wdth' 41.2" Total Racking Weight: 69.39 Lbs q Rafter Span: 16(" Weight: 41.0 Lbs Array Area: 215.76 SOFT e qes Roof Pgrh: 32' Array WeighC 572.07 Lbs itshin IDecking Type: Plank Racking Soece Army Dead Load: 2.65 Lbs1SOFT erkmq Roof Material: 1Lyr-Shingle Type: Invisimount Number of Mounts: 39 na•L.q eon 160^ Number of Floors: 2 Weight: 0.56 Lbs/Ft Load Per Mount: 14.67 Use MOUNTING DETAIL Maximum Allowable Cantilever 2a" 324" 247 3/4" Co sissel L_ N 0) co co N N Elaine A.Huang MA Professional Engineer license p 49029 M BOSTONSOLAR Maximum Allowable Spacing on Omwli ,.bort admr.us I Inro®eoswnso er uc p Neme Layout Date December 10,2015 CUENT INFORMATION: Drawn by MC Joe Morency Checked by 4 West Terrace REva o0 Salem, MA 01970 PV - 3.1 (978) 744-8288 Scale As Noted Solar Module Solar Edge P400 Optimizer Design Conditions: BOSTON LOGAN INTL AIRPORT Sunpower 1120-327 Max Input Vo@age. 60V 4 0 temperature hit °/. l extreme h tem 35°C. Voltage Max Power(VMPP) 57.3V Max Input Current 12.5A gnnuag p ( ) Current Max Power(IMPP) 5.71A Max Output Current 15A 2%Average high temperature:32°C Short Circuit Current(ISC) 6.07A Max Output Voltage 60V Annual extreme low temperature:-17°C Open Circuit voltage(VOC) 67.6V Min(Max Per String 10125 Temperature at 3.5"above roof:49°C (3)#10THWN-2 Woe (3)#10 THWN-2 Wire (1)#10 THWN-2 Ground (1)#10 TNWN-2 Ground 1"EMT 1"EMT M 57 767'263 100 126ABus Load Canter Integrated OC Indener solarEdge AC _ •— SolaDeck-Pass Disconnect 360 !JS RGM Intefface r- 0 • — 1 Through Box DC+ O U 25A r._. .._ DC- 2 O u � Or soc 0000 NEU EM OUIpN:3,800W AC Volt:240V utility Max Amps:16A Disconnect E#:97.5% 60A switch #10 FV Wire (2)#10 THWN-2 Wre #6 Bare Copper Ground 1"EMT Outdoor B09ON SOLAR Newmbon°nWar.us I imo®ambna°Ycm preside Name Line Diagram Det. December 10,2015 CDENTINFORMATION: D.by MC Joe Morency Chechad by 4 West Terrace REV# 00 Salem, MA 01970 PV - 4.0 (978) 744-8288 s.. As Noted ALL LABELS SHALL BE OUTDOOR RATED WEATHER RESISTANT, UV AND WATER RESISTANT BASE SHEET,INKS, CAUTION AND ADHESIVES. SOLAR ELECTRIC 0 PV SYSTEM 0 LALL LABELS ETTERING SHALL BE A RED BACKGROUND WITH WHITE SYSTEM CONNECTED GENERATION METER PROVIALL LABELS SHALL BE REFLECTIVE MATERIAULETTERING. PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC WARNING DANGER DISCONNECT FOR INVERTER INPUT ELECTRIC SHOCK HAZARD! UTILITY OPERATION DC DISCONNECT O DO NOT TOUCH TERMINALS O D DO OFFNOT NOLTAICNECT DISCONER NECT D TERMINALS ON BOTH LINE AND LOAD SIDES TURN OFF PHOTOVOLTAIC SER CONNEDT WARNING WARNING MAY BE ENERGIZED IN THE OPEN POSITION SW TCH PRIOR TO SERVING ELECTRIC ELECTRIC SHOCK HAZARD! SHOCK HAZARD! DO NOT TOUCH TERMINALS.TERMINALS ON OO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE UNE AND LOAD SIDES MAY BE WARNING WARNING ENERGIZED IN THE OPEN POSITION BOTH THE LINE AND LOAD SIDES MAY BE INTERACTIVE SOLAR PV SYSTEM RATING I O PV DISCONNECT BACKFED 0 ENERGIZED IN THE OPEN POSITION ELECTRIC SHOCK HAZARD. INTERACTIVE SOLAR PV SYSTEM RATING Operating DC Currant 15A O IFA GROUND FAULT IS INDICATED, D BREAKER RELOCATE DO NOT REMOVE OR Operating DC Voltage 315 V NORMALLY UNGROUNDED CONDUCTORS RE CONTINUOUS OUTPUT CURRENT 16 AMP MAY BE GROUNDED AND ENERGIZED NORMAL OPERATING AC VOLTAGE 240V Maximum System Voltage 600 V Short Circuit Currant ISA SYSTEM INSTALLER: FOR SERVICE CALL: SYSTEM INSTALLER: FOR SERVICE CALL: UTILITY DISCONNECT WARNING LABEL UTILITY DISCONNECT WARNING LABEL CAUTION WARNING O O THIS METER IS ALSO SOLAR ELECTRIC SYSTEM SERVED BYA WARNING WARNING CONNECTED PHOTOVOLTAIC SYSTEM DC SOLAR CIRCUIT INVERTERCONNECTION DO NOT RELOCATE THIS DC CIRCUIT LABEL OVERCURRENT DEVICE UTILITY DISCONNECT LABEL BOSTON SOLAR WARNING PV SYSTEM DISCONNECT ELECTRIC SHOCK HAZARD! Dr Dg Nem. Labels Page FOR UTILITY OPERATION TM THIRECTCURRENTCIRCUITOONWCNRSOF THISPHO CURRENT CRCUITCON TEM,IRE Date December 10,2015 O UNGROUNDEOSUTMAY OF FNERGaED LHTH CUENT INFORMATION: Dram by RESPECT TOGROUND DUE TO LEAKAGE PATHS ANMRGROUNDFAULM Joe Morency CNeoke4 by MC. 4West Terrace rREV# DD DC WARNING LABEL Salem, MA 01970 PV- 5.0 (978) 744-8288 coa. AS Noted Project Data Codes C MA CMR 78051.00 IB -2009,ASCE 7-05 2005 NDS,NEC-2014 Inverter: SolarEdge3B00A-US RGM ' PV Panel: (12)SunPowerX2032] Racking: Invisimount-Flush To Roof System Racing: 3.92 kW DC-STC tat Year Producton:4,744 kWh Design Factors Gmund Snow Load bapsf Wind speed 100 mph UtllittyMeter ` V Utility Disconnect _ 1 q' V Inverter f- 1 I I 1 1 I 1 a Dl�searsst _ ftlS2__, 'Setback Roof 1 Azimuth: 143°N Tilt:32° Shade: 14% 12 Panels-1.209 BOSTON SOLAR Draving Name Site Plan Date September 17,2015 CLIENT INFORMATION: Dram by BG Joe Morency Checked by 4West Terrace REV# 00 Salem, MA 01970 PV - 2.0 (978)744-8288 scale AS Npted oler Moeula Structure Module Specs Amy ...,mo.I R.0 aw. Structure Type: Rafter Model: SPWR E20-327 Number of Modules: 12 Rafter Size: 24" LanglA: 61.4" Total Module Weight: 502.66 Lbs ..mono Isom Rafter Spacing: 20" Wdth: 41.2' Total Racking Weight: 69.39 Lbs s..moeo Fro.nms N Rafter Span: 160" Weight: 41.0 Lbs Array Area: 215.76 SOFT .ne M.untompo.. aro. Roof Pilch: 32° Array Weight: 572.07 Lbs ° abm Decking Type: Plank Racking Specs Array Dead Load 2.65 Lbs/SOFT Nnn D.01, Roof Material: '1 Lyr-Shingle Type: Invisimount Number of Mounts: 39 ns-L.g eon 160 Number of Floors: 2 Weight: 0.56 LbsfFt Load Per Mount: 14.67 Lbs MOUNTING DETAIL Maximum Allowable Cantilever za° 324" 247 3/4" m N OD _ � (V C4 N r Elaine A.Huang MA Professional Engineer UceneeN 49029 BOSTONSOLAR Maximum Allowable Spacing Dmxing Name. Mr. I inro®eo.ronsororu. Layout Dale December 10,2015 CLIENT INFORMATION: Drain by MC Joe Morency Chocked by 4West Terrace REV 00 Salem, MA 01970 PV- 3.1 (978)744-8288 Scale As Noted Solar Module Solar Edge Pogo Optimizer Design Conditions: BOSTON LOGAN INTL AIRPORT Sunpower E20-327 Max Input Voltage 80V Voltage Max Power(VMPP) 57.3V Max Input Current 12.5A Annual extreme high temperature(0.4%):35°C Current Max Power(IMPP) 5.71A Max Output Current 15A 2%Average high temperature:32'C Short Circuit Current(ISC) 6.07A Max Output Voltage 60V Annual extreme low temperature:-17°C Open Circuit Voltage(VOC) 67.6V Min/Max Per String 10/25 Temperature at 3.5"above roof:490C (3)#10 THWN-2Wre (3)#10THWN-2Wre (1)#10THW1-2Grouna (1)#10 THNM-2 Ground VEMT 1'*EMT M 57767283 100A Load Bus Loed Cenler Integrated DC Invader SolerEOge AC SolaDeck-Pass Disconnect 3800-US ROM Interface r' Through Box l DC- 0 I + _ + _ + O i 25A 2 12 ' Dc- --. I 0. J Dc o --- .� Or i NEU ease oMPut:3,60ow AC von:240V utility Max Amps:16A Discerned ER:97.5% 60A Switch #10PVWre (2)#10 THWI-2Wre 96 Bare Copper Ground 1"EMT Outdoor BOSTONSOLAR x—bosensobrUs I inro®eostonsoocm Drawing Name Line Diagram Data December 10,2015 CLIENT INFORMATION: Drewn by MC Joe Morency CheQed by 4 West Terrace Rev# 00 Salem, MA 01970 PV -4.0 (978) 744-8288 scale AS Notetl ALL LABELS SHALL BE OUTDOOR RATED WEATHER RESISTANT, UV AND WATER RESISTANT BASE SHEET,INKS, CAUTION AND ADHESIVES. SOLAR ELECTRIC O PV SYSTEM o LALL LABELS ETTERING P OVHALL BEA RED BACKGROUND WITH WHITE SYSTEM CONNECTED GENERATION METER ALL LABELS SHALL BE REFLECTIVE MATERIAL&ETTERING. PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC WARNING DANGER DISCONNECTFOR INVERTER INPUT ELECTRIC SHOCK HAZARD! DC DISCONNECT O DO NOT TOUCH TERMINALS O O DO NOT PHOTOVOLTANECT IC ISC LOAD O UTILITY OPERATION TURN OFF PHOTRI OLTO S DISCONNECT TERMINALS ON BOTH LINE AND LOAD SIDES SIMTCH PRIOR TO SERVING WARNING WARNING MAY BE ENERGIZED IN THE OPEN POSITION ELECTRIC ELECTRIC SHOCK HAZARD! SHOCK HAZARD! DO NOT TOUCH TERMINALS.TERMINALS ONI, DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE WARNING WARNING IN THE PEN POSITION BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED O PoS 0 ENERGIZED IN THE OPEN POSITION INTERACTIVE SOLAR PV SYSTEM RATING ELECTRIC SHOCK HAZARD! O PV DISCONNECT BACKFED O INTERACTIVE SOLAR PV SYSTEM RATING Operating DC Current 15A O O BREAKER DO NOT REMOVE OR IF A GROUND FAULT IS INDICATED, RELOCATE CONTINUOUS OUTPUT CURRENT 16AMP Operating DC Voltage its NORMALLY UNGROUNDED CONDUCTORS MAY BE GROUNDED AND ENERGIZED NORMAL OPERATING AC VOLTAGE 1 240 V Maximum System Voltage 600 V Short Circuit Current 15A SYSTEM INSTALLER: FOR SERVICE CALL SYSTEM INSTALLER: FOR SERVICE CALL: UTILITY DISCONNECT WARNING LABEL UTILITY DISCONNECT WARNING.LABEL CAUTION WARNING O O THIS METER IS ALSO SOLAR ELECTRIC SYSTEM SERVED BYA WARNING WARNING CONNECTED PHOTOVOLTAIC SYSTEM DC SOLAR CIRCUIT INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS DC CIRCUIT LABEL OVERCURRENT DEVICE UTILITY DISCONNECT LABEL I«E BOSTON SOLAR WARNING PV SYSTEM DISCONNECT ELECTRIC SHOCK HAZARD! w boeoosobrus ®BeslunscYl.u. DnmN Name Labels Page EDIRECTOURRENTCIROURCONWCTORSOF FOR UTILITY OPERATION THISPROTOVOLTAIC PoWE CONDUMARE Dale D¢C¢mb¢f 10,2015 O UNGROUNDEDBUTNAY SEENERGIZEDLTH CLIENT INFORMATION: D.by RESPEOTTO GROUND DUE TO IEdxAGEPATHS ANMR GROUND FAULTS Joe Morency Cbe¢,xi by MC 4 West Terrace REV# DD DC WARNING LABEL Salem, MA 01970 PV - 5.0 (978) 744-8288 Sale A.Nola SOLAR PANFLS �, 4 ( HIGH PERFORMANCE & EXCELLENT DURABILITY ,r ^• f SERIES q�� e3 • 20.3% efficiency Ideal for roofs where space is at a premium x20-327 PANEL or where future expansion might be needed. • Maximum performance HIGHEST EFFICIENCY° Designed to deliver the most energy in Generate more energy per square foot demanding real world conditions, in partial shade and hot rooftop temperatures.1,2.3 X-Series residential panels convert more sunlight to electricity producing 44% more power per panel,' and 75% more energy per square foot is Premier technology over 25 years.3,4 Engineered with the newest and most 7 powerful Maxeon technology, X-Series HIGHEST ENERGY PRODUCTION brings unmatched power and performance Produce more energy per rated watt to your home. High year one performance delivers 8-10% more energy per rated Wor".3 This advantage increases over time, producing 21% more energy over the first 25 years to meet your needs.' 0 120% 21 % More Energy 110% Per Rated Watt p 100% 9%more,year is Maxeon®Solar Cells:Fundamentally better. 0 90% 36%more, Engineered for performance,designed for durability. o_ year 25 80% Engineered for peace of mind "= 70% Q3 a, Designed to deliver consistent, trouble-free 60% energy over a very long lifetime.4,5 r 50% Designed for durability 0 s 10 Years 15 20 25 The SunPower Maxeon Solar Cell is the — eEor< t 0 only cell built on a solid copper foundation. 3 Maintains High FEN R Virtually impervious to the corrosion and a% Power at High Temps o No Light-Induced cracking that degrade Conventional Pxororr= Degradation a, <hst� Panels 4,5 0 6% eEro Q --I High Average Wafts ----------- Same excellent durability as E-Series panels. a 4% Better Low-Light and A<rd.i P.—E-S.roi #1 Ranked in Fraunhofer durability test.10 Spectral Response morem 100% power maintained in Atlas 25* 2% _ High-Performance comprehensive PVDI Durability test.'' `0 0% Anti-Reflective Glass } __. www.sunpower.com SUNPOWER X-SERIES • . PANELS SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY POWER WARRANTY PRODUCT WARRANTY l00% j 95% ry� 90% C! 85% 80% S� 75% 0 5 10 15 20 25 0 5 10 15 20 25 Yeon Years More guaranteed power: 95%for first 5 years, Combined Power and Product defect 25 year coverage -0.4%/yr.to year 25.8 that includes panel replacement costs. ELECTRICAL DATA OPERATING CONDITION AND MECHANICAL DATA X20.327_ Temperature -40aF to+18511-40'C to+851C) Nominal Power12(Pnom) 327 W Wind:50 psf, 2400 Pa,245 kg/m2 front&back Max load P2 1 1 Snow: sf,5400 Pa,550 k m2 front Power Tolerance +51-0% S Y 9/ Avg. Panel Efficiency13 20.3% Impact resistance 1 inch(25mm,diameter hail at 52 mph 123 m/s). Rated Voltage (Vmpp) 57.3 V — Appearance Class A+ Rated Current(Impp) 5.71 ASolar Cells _ -96 Monocrystall ne Maxeon Gen III _ Open-Circuit Voltage (Voc) 67.6 V Tempered Glass High transmission tempered Anti-Reflective _ Short-Circuit Current(Isc) 6.07 A Junction Box _ IP-65 Rated ---- --------- Connectors MCA Compatible Connectors Max. System Voltage 600 V UL& 1000 VIEC — --M - --aximum Series Fu---- - ---se 15--- -- --- -- --- - - ----- A 1___ 5--- - --- Frame Class 1 black anodized(highest AAMA rating, Power Temp Coef. -0.30%/oC Weight 41 lbs 118.6 k9l Voltage Temp Coef. -167.4 mV/aC TESTS AND CERTIFICATIONS Current Temp Coef. 3.5 mA/eC Standard tests UL1703 (Type 2 Fire Rating), IEC 61215, IEC 61730 REFERENCES: Quality tests ISO 9001:2008, ISO 14001:2004 1 All comparisons are SPR-X21-345 vs.a representative conventional panel:250W, EHS Compliance RoHS,OHSAS 18001:2007, lead Free approx. 1.6 m2, 15.3%efficiency. Ammonia test IEC 62716 2 PVEvolution Labs"SunPower Shading Study,'Feb 2013. Salt Spray test IEC 61701 (passed maximum severity, 3 Typically 8-10%more energy per waft, BEW/DNV Engineering "SunPower Yield -- ---- -- — -- -- --- — ----_ - Report,'Jan 2013,with CFV Solar Test Lab Report#12063,Jan 2013 temp.coef. PID test Potential-Induced Degradation free: 1000V10 calculation; Available listings UL,CEC,TUV,MCS 4 SunPower 0.250//yr degradation vs. 1.0%/yr conv. panel. Campeau, Z. et al. — "SunPower Module Degradation Rate,'SunPower white paper, Feb 2013;Jordan, Dirk'SunPower Test Report,"NREL,Oct 2012. 5'SunPower Module 40-Year Useful Life"SunPower white paper,Feb 2013.Useful life is 99 out of 100 panels operating at more than 70%of rated power. 6 Highest of over 3,200 silicon solar panels,Photon Module Survey,Feb 2014. 1 1046 mm 7 1% more energy than ESeries panels, 8% more energy than the average of the [41.2 In) top 10 panel companies tested in 2012 (151 panels, 102 componies,, Photon International,Feb 2013. r 8 Compared with the top 15 manufacturers. SunPower Warranty Review, Feb —F 2013. 9 Some exclusions apply.See warranty for details. 46 mm-►I�- - 1559 mm 10 XSeries same as ESeries, 5 of top 8 panel manufacturers from 2013 report [1.8 In] I� [61.41r1] were tested, 3 additional silicon solar panels for the 2014. Ferrara, C., Of al. "Frounhofer PV Durability Initiative for Solar Modules: Part 2". Photovoltaics International,77-85. 2014. 11 Compared with the nortstmsstested control panel. XSeries some as ESeries, tested in Atlas 25+Durability test report,Feb 2013. 12 Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,25a C). 13 Based on average of measured power values during production. See help://www.sunpowr.com/focts for mora rePereoas information. For mora details,see extended datasheeL wwwsunposer.com/dotasheets.Read sultry and installation inslmctiom before using this product www.sunpower.com ODecember 201A SunPower Cor oraflon.All rights reserved.SUNPOWER,the SUNPOWER logo,MAXEON,MORE ENERGY.FOR UFE.,and SIGNATURE are mucher rla or registered imenlASoa955 Rert/aILuS aodemarks of SunPower Corporation.SpriRcasons vcluded in this dotashwt are subject us cluster,without notice. solar � � SolarEdge Single Phase Inverters For North America SE300OA-US / SE3800A-US / SE5000A-US / SE60OOA-US SE7600A-US / SE1O0OOA-US / SE11400A-US '° as � a 1 y 3 7 N� 19 f 41 77 i 1.. Z �k l ; v- r' 1 a a „',+z t + t Y r 4Y fid` �sem„ The best choice for SolarEdge enabled systems - Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance — Superior efficiency(98%) 4 — Small, lightweight and easy to install on provided bracket 9 — Built-in module-level monitoring t — Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter, DC/AC conversion only — Pre-assembled Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us solar=@e Single Phase Inverters for North America SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ SE760OA-US/SE10000A-US/SE1140OA-US SE3000A-US I SE380OA-US SE5000A-US SE600DA-US SE760OA-US SE10000A-US SE1140OA-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA ........................................... ................ ............... ................. . 240V, ............... ................ .1..0000,@ . .................. ........... Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA ........................................... ................ . saso.@zaoy.. . o9so,@zaoy.. .................. ........... ... . ..5 ............... ............... AC Output Voltage Min.-Nom.-Max.(') 183-208-229 Vac ✓ J . ............................... AC Output Voltage .......... ................ ............... ................. ................ ................ .................. .................. ........... aMin:Nom:MaxP) J J ✓ ✓ ✓ ✓ ✓ 211-240-264 Vac ...................................i....... ................ ............... ................. ................ ................ .................. .................. ........... AC Frequency Min.-No .Max.' 59.3-60-60.5(with Hl country setting57.60.60.5) Hz 24 @ 208V 48 @ 208V Max.Continuous Output Current..... 125......I......16......I..21,�41240V.„I.,,,. ,25..,..„I,. ..,32 -I...42.@.240V...I..... 475 ...... ... A .... . ...... . ..4.... . GFDI 1 A Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes INPUT Recommended Max.DC Pore i') 37504750 6250 7500 9500 12400 14250 W .................................... ................ ..... ..................... ................. ........... .......... .................. .................. ........... Transformer less,Ungrounded Yes ....... . .... .... . ....... .. .. .......... ... ............... ........... ........... Max.Input Voltage..................... ..........................................................500 Vdc ........................................................... ........... Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc Max.Input Current..) Adc .................................... 9.5..... ( ...13... 115.5,@ 240V I ....18.. I .23....... ..3035V..I.. ...34.5....... ... . . ... Max.Input Short Circuit Current45 Adc Y .................. ....................... .......................................................................................................................... ........... Reverse-Polarit Protection .........................................................Yes ........................................... .. ........................................................... ........... Ground-Fault Isolation Detection 600kn Sensitivity ......................... .:............... ................ ............... ................. ................ ................ .................. .................. ........... Maximum nverter inyency.......... .....97:x...... .....98:2..... ......98:3...... .....98:3...... ......98...... .......98........ .......98........ .... ..... 97 @ 208V CDC Weighted Efficiency 97.5 98 97.5 @ 208V 97.5 97.5 97.5 ........................................... ................ ............... .. 98,�1a.240V.. 240V.. .................. ........... Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces R5485,RS232,Ethernet,ZigBee(optional) ........................................... .................................................................ii....................................................... ........... Revenue Grade Data,ANSI C12.1 Optional” Rapid Shutdown—NEC 2014690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed 151 STANDARD COMPLIANCE Safety UL3741,UL1699B,UL1998,CSA 22.2 ........................................... .......................................................................................................................... ........... Grid Connection StandardsIEEE1547 .. misson................................ .........................:...........................0 p'a' tlS.........................................I................. ........... Emissions FCC part16 class B INSTALLATION SPECIFICATIONS ACoutput conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG ........................................... ...........................................I....................... ...................................................... ........... DC input conduit size/#of strings/ AWG ran e3/4"minimum. 1-2 strings/16-6 AWG 3/4"minimum/1-2 strings 114-6 AWG Dimensions with Safety Switch 30.5x 12.5 z7/ 30.Sx 12.5 x7.5/ 30.5 z 12.5 x 10.5/ 5 0 m/ 77 x 315 x 26 mm.. Wei ht with Safet Switch 512/232 547/247 88.4/40.1. Ib/.k .....8..............Y.................... ......... ......... .. .... . .. . ...... . I..... . .. .. . . ... ..I. .... &... Coolin Natural Convection Fans(user re Iaceabie) .......................................... ................................................................... . ......P......................... ....... ... . Noise <25 <50 dBA ........................................... ......................:............................................ ...................................................... ........... Min.-Max.Operating Temperature -13 to+140/-25 to+60(40 to+60 version availableia)) -F/-C Range..................I............... . ......................................................................................................................... ........... Protection Rating NEMA 3R ......................................................................................................................... ........... I')For other regional seMngs please contact SolarEdge support. IE limited to 125%for lorzdons where the yearly average high temperature is above 77'F/35'C and to 135%for locations where it is below]7'F/25'C. For data i led lnformaton,refe r to ed e s de. d nIA higher current source may be used;the inverter will limit its input current to the values stated. _ lal Revenue grade inverter P/N:SEnrxxA-U5000NNR2 ISI Rapid shutdown kit P/N:SE1000-R50-51 lel 40 version P/N:SEw-A-USOOON NU4 a ^x�ov R4PIYa �I_ 4 p Yw t '[4 i8 t':f .C`9y'. r SUIr IrSPEC 4 , ++ x � - �h -k" beer Rgiw solaror 4 ,=:" le a SolarEdge Power Optimizer Module Add-On For North America P300 / P400 / P405 � t ®: M Ytltl .,.P" .: i"�1� 8 v'�'��f �i:`•'�', � p. ,uk ' aka" `AX Y � Y '{ � n 6 t-t a, Y e x¢. k d� "p Pt ro � PV power optimization at the module-level — Up to 25% more energy - Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization , — Fast installation with a single bolt — Next generation maintenance with module-level monitoring , — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.Solaredge.us s R so I a r " • ® � SolarEdge Power Optimizer Module Add-On for North America P300 / P400 / P405 P300 P400 P405 (for 60-cell modules) (for 72&96-cell modules) (forthin film modules) INPUT Rated Input DC Powerl'I 300 400 _ 405 W . ........... ............................... . . .. ... ... . ............. . ..................... . Absolute Maximum Input Voltage 48 80 125 Vdc (Voc at lowest temperature). ................ .................... ......... .................... .................................. .................................. MPPTOperating Range.......................... .............$.:48.............. .............$.:80.............. ...........12.5:105........... ... Vdc..... Maximum Short Circuit Current(Isc) 10 Adc ..................... .. .......... ................................... .................................................. . .... Maximum DC Input Current ,. ,..125 Adc. Maximum Efficient .................99:5 .,,,%,,,,,. ......................... .............................. ................................ ................................................. . WeightedEfticiencY............................... .................................................98:8................: ....%...... Overvoltage Category OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current .. .,..,.._ 15 Adc ...................P...... ..g........................ ....................................... ............... .................... Maximum Output Voltage 60 I 85 Vdc .OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMCFCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 ........................................................ ........................................................................................................ ... .......... Safety.............................................. ...............................IEC62109:1(class II safety);.UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltagge............ .................................................1000................................................. ... Vdc..... . ....................... . ....... Pxxx-2 series 141x212x40.5/S.SSx8.34x1.59 - mm/in . ..... ..............I............. . . ....... ...............I.................. ............. Dimensions(W xLx H) 128x 152x27.5/ 128x152x35/ 128x152x48/ Pxxx-5 series 5 x 5.97 x 1.08 5 x 5.97 x 1.37 5 x 5.97 x 1.89 mm/in ..Weight(including...... cables) ...................... .................................. ...............0/ .............. .................................. ............. Pxxx-2 series 950/.2:1 .v . xxx-............... .................................. .................. ................................. .Pxxx.S series...... ............770/,1.7........... 9.30../..2.05 2;05........... 930/,2.05....... . . �................. ...I............. .... .. Input Connector .........................................MC4 Compatible............................,............. Output Wire Type/Connector Double Insulated;Amphenol ...... ... .... .. ...... .. . . ..... . ...... ....... . ...... .......... .. ............. . ...0:95/,30 . .... ..I. ......... .......... ... . 12/39........................... .. ..M/ft .. Operating Temperature Rang°.e.................. ........................................40:+85/,'40-+185............................:.......... ...-C l/, F... Pxxx.. series I. . . NEMA4........................................... ..gr/Ib... ProtectionRating ..........erie ...... ....................I.......I..................... . ..... ...... .................. .Pxxx.S series...... ...........................................IP68/.NEMA6P........................................... ...g!/Ib... Relative Humidity 0-100 ....%...... I'"Raced STC power of IM1e mod ule.Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTERI'I Minimum String Length 8 10 18 „(Power Optimizers) Maximum String Length 25 25 50er ..(PowOptimizers)............................... ....................... ............ ............ m ...................... ................................... ............. MaximuPower per String..................... ..............5250.............. ..............6000.............. .............12750............. ............. Parallel Strings of Different Lengths Yes or Orientations a le not allowed m m.....p.ans ie:.................................. ......oa-....... ......... ..... ....... ... ................ .......... ...................... .................... ............. w¢M1 p3oo/peso/Paoo/psoo/poo m pul s i f R tji y i s r r r r , z r ay t < e !eke a* Simple and Fast Installation Integrated module-to-rail grounding Pre-assembled mid and end clamps • Levitating mid clamp for easy placement Mid clamp width facilitates even module spacing Simple,pre-drilled rail splice UL 2703 Listed integrated grounding Flexible Design — Addresses nearly all sloped residential roofs Design in landscape and portrait Pails enable easy obstacle management b Customer-Preferred Aesthetics , #1 module and#1 mounting aesthetics Best-in-class system aesthetics Elegant Simplicity Premium,low-profile design Black anodized components SunPower® InvisiMountTM is a SunPower-designed Hidden mid clamps and end clamps rail-based mounting system. The InvisiMount system hardware,and capped,flush rails addresses residential sloped roofs and combines faster Part of Superior System Installation time, design flexibility, and superior aesthetics. • Built for use with SunPower DC and AC modules The InvisiMount product was specifically envisioned and • Best-in-class system reliability and aesthetics Combine with SunPower modules and engineered to pair with SunPower modules. The resulting monitoring app system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers. 41111 Usunpower.com � ot m� i M1' l' 3Cc"� Module*/Mid Clamp and Rail Module*/End Clamp and Rail Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly End Cap } rn* Component Material Weight Temperature -40°C to 90'C(-40'F[0 194'P) Max.Load 2400 Pa uplift Mid Clamp Black oxide stainless steel AIS1304 63 g(22 oz) 5400 Pa downforce End Clamp Black anodized aluminum alloy 6063-T6 110 g(3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m(9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m(9 oz/ft) Warranties 25 year product warranty Ground Lug 304stainlessc 5-year finish warranty g Assembly (A2-70 bolt;tin-plated copper lug) 106.5 g/m(3 75 oz) End Cap Black acetal(POM)copolymer 10.4 g(0.37 oz) UL 2703 Listed Certifications Class A fire rating when distance between 9 roof surface and bottom of Sun Power e_ module frame is s 3.5' Composition Shingle Rafter Attachment Composition Shingle Roof Decking Attachment • ' Application Curved and Flat Tile Roof Attachment Universal Interface for Other Roof Attachments Refer to roof attachment hardware manufacturers documentation *Module frame that is compatible with the Invisi Mount system required for hardware interoperability. 0 2015 Sunpower corporation. All Rights Reserved. SUNPOW ER,the SUNPOW ER logo,and INVISIMOUNT are trademarks or registered trademarks of Sun Power Corporation. All other trademarks are the property of their respeRive owners sunpowercom Specifications included in this dataeheet are subject to change without notice. Document#509506 Rev B STRUCTURAL ENGINEERS November 24, 2014 SunPower Corporation 1414 Harbour Way South Richmond, CA 94804 TEL: (510) 540-0550 Atm.: Engineering Department, Re: Engineering Certification for the SunPower Corporation Invisimount Design Tool This letter is to document that PZSE, Inc.-Structural Engineers has reviewed SunPower's Invisimount Design Tool, an online tool that: • Evaluates structural design loads on SunPower Invisimount solar arrays • Evaluates the maximum allowable spacing of attachments of the system to the roof to resist design loads • Estimates the bill of materials for specific projects to assist with ordering parts from SunPower SCOPE OF THE TOOL: Invisimount by SunPower is a solar panel support system for installing solar photovoltaic arrays on sloped roofs of buildings. Typically such buildings are residential with shingle or tile roofs. Each row or column of modules is supported by two rails,which are attached to the roof structure. The number and spacing of attachments to the roof structure can vary depending on, for example, structural loads at a particular site,the type of attachment hardware used, and spacing of the supporting roof structural members. SCOPE OF OUR REVIEW: PZSE, Inc.—Structural Engineers provided a review of the following • Invisimount online Design Tool algorithm and design methodology and has determined that the Invisimount Design Tool is a rational approach and is in compliance with the structural requirements of the following Reference Documents: 1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-05 2. International Building Code, 2009 Edition, by International Code Council, Inc. 3. Aluminum Design Manual,2005 Edition, by The Aluminum Association 4. AC428, Acceptance Criteria for Modular Framing Systems Used to support Photovoltaic (PV)Panels, November 1, 2012 by ICC-ES This letter certifies that the Invisimount online Design Tool is in compliance with the above Reference Documents. 8150 Sierra College Boulevard,Suite 150 • Roseville,CA 95661 • 916.961.3960 P • 916.961.3965 • www.pzse.com Page 1 of 2 STRUCTURAL ENGINEERS DESIGN RESPONSIBILITY: The Invisimount Design Tool is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases,the tool should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: Evaluate whether the tool is applicable to the project, based on the "Engineering Basis of Calculations"document and the characteristics of the project, and • Understand and determine the appropriate values for all input parameters of the tool. Results of the tool should be checked against the design professional's judgment. Excerpts from standards such as ASCE 7-10 are presented in the tool as pointers to the standard and are not intended to diminish the user's responsibility to consult the applicable figures and sections of the standard directly. The user or design professional in responsible charge assumes full design responsibility. The tool does not check the capacity of the building structure to support the loads imposed on the building by the array, such as bending strength of roof rafters spanning between supports. This requires additional knowledge of the building and is outside the scope of the design tool and our review. Please feel free to contact me at your convenience if you have any questions. Sincerely, ut� Paul Zacher, SE- President �'jH OFh�S3 9 PAUL K. ZACHER TRUCTURAL m 50100 /S TERM NALE ' axp.6/30/16 8150 Sierra College Boulevard,Suite 150 • Roseville,CA 95661 • 916.961.3960 P • 916.961.3965 • www.pzse.com Page 2 of 2