FINAL HERS RPT UNIT 2, 04/23/2019 Home Energy Rating Certificate Rating Date: 2019-04-23 Enn ,'
Final Report Registry ID: 775027366 H l 1,1
Ekotrope ID: 7dBRrN5d
HERS® Index Score: Annual Savings Home:
Your home's HERS score is a relative performan 424 13 Meadow St APT 2
The lower the number,the more energy efficiere 5
Salem,MA 01970
home.To learn more,visit www.hersindex.comir
"Relative to an average U.S.home Builder:
Torgerson
Your Home's Estimated Energy Use: This home meets or exceeds the
Use[MBtu] Annual Cost criteria of the following:
Heating 24.2 $472 2015 International Energy Conservation Code
Cooling 0.5 $27
Hot Water 7.0 S133
Lights/Appliances 13.6 S625
Service Charges $190
Generation(e.g.Solar) 0.0 $0
HERS Index Home Feature St4ereary: $1,447 Rating Completed by:
..,.ro.r' Home Type: Apartment.end unit Energy Ratar:lan Rex
Model: N A
RESNETID:1454792
E.rsnng K. Community: N(A
Homes
Conditioned Floor Area: 879 sq.ft.
Number of Bedrooms: 2 Rating Company:Tlte Energy Hound
Reference 00 Primary Heating System: Furnace•Natural Gas.92.t AFUE PO Box 177,Kittery Point,ME 03905
Home 978-233-1933
" Primary Cooling System: Air Conditioner•Electric•13 SEER
AC Primary Water Heating: Water Heater.Natural Gas•0.93 Energy Factor
House Tightness: 408 CFM5012.81 ACH50) Rating Provider:Energy Raters of Massachusetts P w,--.,N
Ventilation: 52.0 CFM.5.5 Watts 2 Woodlawn Street Amesbury,MA 01913 a
Te{H.m. Duct Leakage to Outside: 0CFM25 i0.'100 s.f.i 978-270-3911 ....." 7
" Above Grade Walls: R-21 �•s..
20
Ceiling: Vaulted Roof,R-38
ter"E„e gy a Window Type: U-Value:0.28,SHGC:0.28
imp rs,rwin Foundation Walls: N:A
IECC 2015 Label
13 Meadow St APT 2
Ekotrope RATER - Version: 3.1.1.2157
HERS® Index Score: 53
Ilding Envelope Specs
Ceiling: R-38
Above Grade Walls: R-21
Foundation Walls: NIA
Exposed Floor: R-30
Slab: N/A
Infiltration: 408 CFM50 (2.81 ACH50)
Duct Insulation: R-6
Duct Leakage: 0 CFM @ 25Pa
Window 8 Door Specs • _
U-Value: 0.28. SHGC: 0.28
Door: R-3
ankitt E*OntOrit'S
Heating: Furnace • Natural Gas • 92.1 AFUE
Cooling: Air Conditioner • Electric • 13 SEER
Hot Water: Water Heater • Natural Gas • 0.93
Energy Factor
Bander or Ensign Professional
Signature:
Building Summary
The
4
Thea.s
Property Organization Inspection Status HOOD 13 Meadow Sr APT 2 Ener y Hound 2019-04-23 D
Salem MA 01970 978-233.1433 Rater ID(RTIN) 1454792
ian Rex RESNET Registered'Confirmed)
over common.
SALE Meadow,Si 13-2 Builder
Torgerson
General Building information
Number Of Bedrooms 2
Number Of Floors 1
Conditioned Floor Area[sq.ft] 879
Unconditioned attached garage? No
Conditioned Volume[cu.ft 1 8.699
Total Units in Building 2
Residence Type Apartment end unit
Floor Number 2
Model
Community
Climate Zone 5A
Basement Wall
None Present
Basement Wail Library List
None Present
Slab
None Present
Slab Library List
None Present
Framed Floor
Name Library type Carpet R Floor Grade Surface Area Location
Adiabatic ADIAE PG R30°in Gvc 0 ADo,e Grade 879 0 sq rt Conditioned Space
Adiabatic,
1
Building Summary ..
The:-'
Property Organization Inspection Status Ener
13 Meadow St APT 2 inc Energy IIHound 2019.04.23 1 1 1 1
Salem MA 01970 976-233-1433 Rater ID tRTIN l 1454792
Ian Rex RESNET Registered(Confirmed)
over common
SALE MeadowSt 13-2 Builder
TOrgerson
Framed Floor Library List
Name Effective R-value
ADIAB PG R30 Fin a,c 27;_=,
Rim Joist
Name Library Type Surface Area Location
Bands-stairs •Cavitti Band FG1 R21-R20 20 0 sq ft Exposed Exterior
+Exp Ply.WrapNinvli
Bands-stairs 'Conlin Band FG1 R21-R22 29 0 sq ft Conditioned Space,Adiabatic)
ADIABATIC Exp Ply,Wrap/V nyll
Rim Joist Library List
Name Effective Insulation R-value
'Ciro,Band FG1 R21-R20 19 65
)Exp:Pi Wrap+Vlnvi
‘Conan Band FG1 R21--R22 22 35
IExp Ply Wrap.tinpu
Wall
Name Library Type Surface Color Surface Area Location
Adiaoatic FG3 R13 ADIAB Medium 532 0 sq ft Conditioned Space(Adiabatic)
Amb;ant DF225 -+i R21_;y p.id Medium I 330 0 sq ft Exposed Exterior
S1awv eil wails-warm F 33 R13 ADIAB Medium 95 0 sq ft Conditioned Space(Adiabatic)
Wail Library List
Name Effective R-value
FG3 R13 ADIAB 10 047
LDFg2 5 Hi R21 Gvp.fd 15 736
2
Building Summary d'he ;yam
Property Organisation Inspection Status LB ,~
13 Meaoov St APT 2 The Energy riouna 2019.04-23 H 1'1
Salem.MA 01970 978-233-1433 Rater ID iRTINI 1454792
Ian Rex RESNET Registered,,Confirmed i
over common
SALE Meadov.St 13-2 Builder
Torgerson
Glazing
Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhan Ft To Orientation Surface Area
Assignment Top Bottom
A 3 2 0 4 0 28 28 Ambient, 0 0 Northwest 32 0 sq ft.
8 1 2 0 1 9 28 28 Ambient! 0 . 0 Southwest 4 0 sq.ft
Back A 1 2 0 4.0 26 28 Ambient 0 0 0 Southeast 8 0 sq ft
Back OrJ 0:blii_oE:Aig• Ambient 6 1 7 Southeast 5 0 sq.ft.
Vim
C 31 23 Ambient 0 C 0 Southwest 18 0 sq.ft
Front dr 2b1 oE.Arg- Amb,ant 5 1 7 Northwest 5 0 sq ft
Vim!
Right A 4 2 0 4.0 26 28 Ambient' 0 C 0 Southwest 24.0 sq ft
I
Glazing Library List
Name Shgc U•factor
2828 328 • 0280
31 23 0 23 0 310
Db11LoEArg-vinyl 0 45 0 330
Skylight
None Present
Skylight Library List
None Present
3
•
Building Summary o .-
The A"
Property Organization Inspection Status ie t ""
13 Meadow St APT 2 Tne Energy mound 2019-04.23 uiul
Saiem MA 01970 978-233-1433 Rater ID(RTIN i 1454792
ian Rex RESNET Registered(Confirmed
over common
SALE Meado-,Si 13-2 Builder
Tome rson
Opaque Door
Name Library type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location
Assignment Absorptance
Back Door R-3 Arnbiant 0 9 0'c Medium 20 0 sq ft Exposed Exterior
From Door R.3 Arabian. 0 9 0 7. Medium 20 0 sq ft Exposed Exterior
Opaque Door Library List
Name Effective U•tactor
Door R-3 0t,r,3
Roof Insulation
Name Library Type Attic Exterior Arta Clay or Concrete Roof Surface Color Surface Area Location
011 Tiles
PGEati.Aoiara'_• L_= 1C c R;S 679 Nc Medium 879 0 sq ft Vaulted Roof
Roof Insulation Library List
Name Has Radiant Barrier Effective R-value
LDF 10'39 R38 Nc 32 387
Whole House Infiltration
Infiltration Measurement Type Shelter Class
408 CFM at 50 Pa "1 . ri 1 „•es'ed 4
Mechanical Ventilation
Ventilation Type Ventilation Rate(Cubic Feet Operational hours per day Fan Watts Runs once every three Energy Recovery Percent
Minute) hours
Exhaust Con 24 t b Yes 0
4
Building Summary
The t
ra:4Property Organization Inspection Status .
13 Meadow St APT 2 Tne Energy Hound 2019-04-23 H i,i I
Salem MA 01970 978-233-1433 Rater ID IRTIN) 1454792
Ian Rex RESNET Registered(Confirmed)
over common.
SALE MeadowSt 13-2 Budder
Torgerson
Lighting
°m Interior Fluorescent %Interior LED Lighting %Exterior Fluorescent %Exterior LED Lighting %Garage Fluorescent %Garage LED Lighting
Lighting Lighting Lighting
1 t'' 00 i`;q 0 1 OC
Onsite Generation
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load
Air conditioner;2; AC 4A7A3030111325sAri 0% 100% 0'°
4TX::80033S3 29Ko=x AMERICAN
CT!Alf Ann w L1,-,167
Fuel•Tired air G-PG92SCS3004CA 92 1'°37K0 100'° 0% 0'0
distribution 11 385e pane a 7126237
Water Heating i3i a.Gi RU160i 93°:Rinnai(REU_ 0% 100%
N253Crr-:_ ,n 10 954t2
5
Building Summary
The ` : ,.
Property Organization Inspection Status ail�
13 Meadow St APT 2 Inc Energy Hound 2019-04-23 1 I
Salem MA 01970 978-233-1433 Rater ID(RTIN). 1454792
Ian Rex RESNET Registered(Confirmed)
over common.
SALE tdeadoi:St 13-2 Builder
Torgerson
Equipment Type: AC 4A7A3030H1 13.25s AH 4TXCB003DS3
29Ko F x AMERICAN STANDARD#9152292
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSC(Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity[kBtuihj 33 6
Equipment Type: GF PG92SCS30040A 92.1% 37Ko 385e Payne
# 7126237
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSC(Single Speed)
Heating Efficiency 92 1 AFUE
Heating Capacity[kBtu/h] 37
Use default EAE No
EAE[kWh] 385
Equipment Type: wGI RU160i 93% Rinnai (REU-N2530FF-US) #
10595452
Fuel Type Natural Gas
Distribution Type Hydronic Delivery
Hot Water Efficiency 0.93 Energy Factor
Tankiess9 Yes
6
Building Summary `"�'
The„, - ,
�„ i
Property Organization Inspection Status En •� :
13 Meadow St APT 2 The Energy Hound 2019-04-23 u('I 1 f
Salem MA 01970 978-233.1 433 Rater ID iRTIN) 1454792
Ian Rex RESNET Registered(Confirmed)
over common.
SALE MeadowSt 13-2 Builder
Torgerson
Distribution System
Distribution Type Forced Air
Heating Equipment Fuel-fired air distribution(1)
Cooling Equipment Air conditioner(2)
Sq Feet Served 879
#Return Grilles 4
Supply Duct R Value 6
Return Duct R Value 6
Supply Duct Area[sq ft] 237 33
Return Duct Area[sq.it] 175 8
Duct Leakage to Outdoors(CFM25) 0
Total Leakage 40
Total Leakage Duct Test Conditions Post-Construction •
Use Default Flow Rate Yes
Duct 1
Duct Location Conditioned Space
Percent Supply Area 100
Percent Return Area 100
Duct 2
Duct Location Attic(well vented)
Percent Supply Area 0
Percent Return Area 0
Duct 3
Duct Location Conditioned Space
Percent Supply Area 0
Percent Return Area 0
Duct 4
Duct Location Conditioned Space
Percent Supply Area 0
Percent Return Area 0
Duct 5
Duct Location Conditioned Space
Percent Supply Area 0
Percent Return Area 0
Duct 6
Duct Location Conditioned Space
Percent Supply Area 0
Percent Return Area 0
Ceiling Fan
Has Ceiling Fan Yes
Cfm Per Watt fL,4
Water Distribution
Water Fixture Type Standard
Use Default Hot Water Pipe Length No
Hot Water Pipe Length[ft] 23
At Least R3 Pipe Insulation9 Yes
Hot Water Recirculation System9 No
Recirculation System Pipe Loop Length[ft] 0
Drain Water Heat Recovery? No
7
Building Summary
The .
Property Organization Inspection Status .41
13 Meadow St APT 2 The Energy Hound 2019-04-23 H I'l IA
t
Salem,MA 01970 978-233-1433 Rater ID IRTIN) 145.1792
Ian Rex RESNET Registered(Confirmed)
over common
SALE Meadw.St 13-2 Builder
Torgerson
Clothes Dryer
Fuel Type Electric
Cef 3.61
Field Utilization Timer Controls
Clothes Washer
Label Energy Rating 79 kWh/Year
Electric Rate $0 12:kWh
Annual Gas Cost $6 00
Gas Rate $1 09Therm
Capacity 1 5
'me 1 15
Appliances and Controls
Programmable thermostat? Yes
Dishwasher Size Standard
Dishwasher Efficiency 268 kWh
Range Oven Fuel Natural Gas
Convection Oven? No
Induction Range'? No
Refrigerator Consumption 672 kWh/Year
Notes
Warnings Verified for,..
Exhaust Fan energy
washer 1 15 1 5 79
dyer 3 61
8
RESNET HOME ENERGY rev_
RATING Standard Disclosure Ham,
For home(s) located at: 13 Meadow St APT 2, Salem, MA
Check the applicable disclosure(s) in accordance with the
instructions on the reverse of this page:
V1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home.
I 12. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services
for this home:
. A. Mechanical system design
B. Moisture control or indoor air quality consulting
C. Performance testing and/or commissioning other than required for the rating itself
D. Training for sales or construction personnel
E. Other(specify)
I `3. The Rater or the Raters employer is:
A. The seller of this home or their agent
B. The mortgagor for some portion of the financed payments on this home
C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home
(414. The Rater or Rater's employer is a supplier or installer of products, which may include:
Products Installed in this home by OR is in the business of
HVAC systems f Rater I 'Employer I ;Rater ViEmployer
Thermal insulation systems 1 !Rater I ;Employer I 'Rater I ;Employer
Air sealing of envelope or duct systems 1 !Rater I .Employer Rater ;;(Employer
Energy efficient appliances 1 !Rater ! Employer II ;Rater !Employer
Construction (builder, developer, construction contractor, etc) l !Rater I ;Employer rI Rater ;Employer
Other(specify): 1 !Rater I 'Employer ;Rater ;Employer
I 5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for
Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy
Services Network (RESNET). Rater Certification #: 1454792
Name: Ian Rex Signature:
Organization: The Energy Hound Digitally signed: 4/24/19 at 1:46 PM
I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating
Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating
Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality
control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at
http://resnet.us/standards/RESNET_Mortgage_Industry_National_HERS_Standards.pdf
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
RESNET Form 03001-2 -Amended April 24, 2007
Builder Affidavit
The
Property Organization Inspection Status
13 Meadow St APT 2 The Energy Hound 2019-04-23 1101 I I
Salem, MA 01970 978-233-1433 Rater ID (RTIN): 1454792
Ian Rex RESNET Registered
over common, (Confirmed)
SALE MeadowSt 13-2 Builder
Torgerson
Important Notice to Builder
Builder affirms in this affidavit that all building characteristics described in the Building Summary Report accurately reflect this
New Home. Builder agrees to allow the Home Energy Rating System (HERS) Provider and/or Rater to verify building
characteristics of this New Home fully at the HERS Rater/Provider's discretion. The HERS Provider and Rater do not create or
imply any duty or obligations to Builder or any subsequent owner. Builder is responsible for taking any actions necessary to
protect Builder's interest.There is no guarantee or warranty whatsoever expressed or implied from the HERS Provider or
Rater.
HERS®Index Score:53
Builder Name: Torgerson Builder Signature:
Name: Ian Rex Signature:
Organization: The Energy Hound Digitally signed: 4/24/19 at 1:46 PM
Ekotrope RATER-Version 3.1.1.2157
All resuits are based on data entered b,Ekotrope users Ekotrope discaims al:liabikty for the information shown on this report.