Loading...
5 COUSINS ST - BUILDING PERMIT APP JThe Commonwealth of Massachusetts CITY OF Board of Building Regulations and Standards Massachusetts State Building Code,780 CMR SALEM Revised Mar 2011 Building Permit Application To Construct,Repair,Renovate Or polish a One-or Two-Family Dwelling Tins Section For Official Use Only 6� Building Perm Number: Date L BwWmg Official(Pont Name) Sigsattne Dat SECTION 1:SITE INFORMATION i 1.1 Property Address: 1.2 Assessors Map&Pat cel Numbers 5 Cousins Street I So L LIts Is this an accepted street?yes_ no Map Number Parcel Number 13 Zoning Information: lA Property Dimensio Zoning District Proposed Use Lot Area(sq ft) Frontage(R) 1.5 Building Setbacks(ft) From Yard Side Yards Rear Yard Required Provided Requited Provided Required Provided 1.6 Water Supply:(M,G.L c.40,§54) 1.7 Flood Zone Information: 1.8 8 age Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Mwu ilm❑ On site Check if. es❑ disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Susan Strauss Salem MA 01970 Name(Print) City,State,ZIP 5 Cousins Street 978-744-3300 _ No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(cheep aft that apply) New Construction❑ Existing Building❑ Owner-Occupied O 1 Repairs(s) ❑ 1Alteration(s) 10 Addition ❑ . Demolition ❑ Accessory Bldg.❑ Number of Units! Other ❑ Specify: Brief Description of Proposed WW: Installation of a 2.7 kw(9 p-a-n-eTs-T-ro-o-Tt—op solar arra SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: fMas Official Use Only 1.Building $ 5,000 1. Building Permit Fee:$ Indicate how fee is determined: ❑Standard City/rown Applicai ion Fee 2.Electrical S 11,014 ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire - 4 $ Suppression) Total All Fees:$ No Check .I Check Amo 7 t: Cash Amount: 6.Total Project Cost: $ 16,014 E3Paid in Full ❑Outstanding Balance Due: _ I SECTIONS: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 096385 10/8/2016 Romain Strecker LicenseNumber Expiration Date Namof CSL Holder List CSL Type(see below) U 55 Sixth Road No.and Street Description RRC Unrestricted m 35,000 cu.ft.) Woburn MA 01801 Reur l&2 Family Dwelling Chylown,State,23P Mason Wind6w and Siding Solid Aral Burning Appliances 781-462-8702 permits@bostonsolar.us Ineulatron Telephone Email address I D I Demdlition 52 Registered Home Improvement Contractor(AIC) 1696S8 7/27/2017 Boston Solar/Romain Strecker HIC Regi mition Number Expiration Date RIC Comp Name or HIC Registrant Name 55 Sixth Road per 'ts@bostonsolar.us No.and Stmet Email address rrn MA 01801 781-462-8702 Wobt Ci /Town State Zip Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT'(M.GI-c.152.§25C(6)); Workers Compensation Insurance affidavit must be completed and submitted with 0 is application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes..........M No...........O SECTION 7a:OWNER AUTHORIZATION TO BE COMP TED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUIING PERMIT L as Owner of the subject property,hereby authorize Romain Strecker to act on my behalf;in all matters relative to work authorized by this building Penniapplication. Susan Strauss 12/16/2015 Print[Tuner's Name(Electronic Signature) Date SECTION 7b:OWNER[OR AUTHORIZED AGENT DE TION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and ur derstanding. Romain Strecker 12/16/215 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner vYho hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not I lave access to the arbitration . program or guaranty fund under M.G.L.c.142A.Other important information on the HIC Program can be found at www.MM&gov/oca Information on the Construction Supervisor License can be found at=Lrnass.aov/dns 2. - When substantial work is planned,pmvide the information below: Total floor area(sq.ft.) (including garage,finished asement/attics,decks or porch) Gross living area(sq.ft.) Habitable room ount Number of fireplaces Number of bedmorns Number of bathrooms Number of�aths Type of heating system Number of porches Type of cooling system Enclosed Open 3. `Total Project Square Footage,may be substituted for'"fotal Project Cost' ii I 1 BOSTON SOLAR Homeowner's Agent Authorization Form I SUSj�iJ SSP.E�vSS Print Name-)' am the owner of the property located at address: � J Print Address) I hereby authorized The Boston Solar Company to act as my Agent for the limited purpose of applying for obtaining local building and other permits from the Authority Having Jurisdiction as required for the Installation of a Photovoltaic System located on my Property. 64, Print Name:; �1JS(a1J �1(LI�JSS Customer Signature. S S Date: !I- -Lo 201 J� The Boston Solar Company 55 Sixth Road Woburn,MA 01801 BostonSolar.us (617)858-1645 - - EAH Structural Consulting xi gton, MA 0 Lane Lexington, MA 02421 cl;] PHONE 1.978.406.8921 CA N CON3LILT ITIO Elaine@EAHstructural.com December 8, 2015 To: Boston Solar 55 Sixth Road Woburn,MA 01801 Subject: Structural Certification for Installation of Solar Panels Strauss Residence 5 Cousins Street Salem,MA.01970 To Whom It May Concern, A design check for the subject residence was done on the existing roofing and framing systems for the installation of solar panels over the roof. From a field inspection of the property,the existing roof support structures were observed by the client's auditors as follows: The roof structure of(MPI)consists of composition shingle on roof plywood that is supported by modular howe trusses that are spaced at @ 24"o.c..The trusses have a max projected horizontal span of approximately 27'-0"between exterior load bearing walls,and a slope of 23 degrees.The top chords are 2x6 sections,the bottom chords are 2x6 sections and the web members are 2x4 sections.The truss members are connected by steel gusset plates.The max unsupported projected horizontal top chord span is approximately 9'-6". . The existing roof framing system of(MP1) isjudged to be adequate to withstand the loading imposed by the installation of the solar panels.No reinforcement is necessary. The spacing of the solar standoffs should be kept at 48"o.c.with a staggered pattern to ensure proper distribution of loads. I further certify that all applicable loads required by the codes and design criteria listed below were applied to the Ironridge solar rail system and analyzed.Furthermore,the installation crews have been thoroughly trained to install the solar panels based on the specific roof installation instructions developed by Ironridge forthe racking system and Ironridge for the roof connections. Finally,I accept the certifications indicated by the solar panel manufacturer for the ability of the panels to withstand high wind and snow loads. Design Criteria: • Applicable Codes=Massachusetts Residential Code,8th Edition,ASCE 7-05,and 2005 NDS • Roof Dead Load=8 psf(MP3) • Roof Live Load=20 psf • Wind Speed=100 mph,Exposure B • Ground Snow Load=40 psf - Roof Snow Load=.28 psf Please contact me with any further questions or concerns regarding this project. I -- _ _ Sincerely, $y��tN OF MqS,� S ELAINE A. HUANG ti CIVIL y Elaine Huang,P . ` ., �N 0.49029 c Project Engineer 1 / SlGMAL ENS Strauss Residence, Salem 1 ERFi Structural Consulting 11 E,gpyly–Qa�Lane Lexington,MA 02421 El PHONE 1.978.406.8921 CAF/ CONG3W LT INP, Elaine(�EAHstructural.com Gravity Loading Roof Snow Load Calculations p9=Ground Snow Load= 40 psf pf=0.7 C,Cf I p9 (ASCE7-Eq 7-1) C,=Exposure Factor= 1 (ASCE7-Table 7-2) Cf=Thermal Factor= 1 (ASCE7-Table 7-3) 1=Importance Factor= 1 pf= Flat Roof Snow Load= 28.0 psf Pb=C.pf (ASCE7-Eq 7-2) Cs=Slope Factor= 1 f p,=Sloped Roof Snow Load= 28.0 psf PV Dead-Load=4 psf(Per Boston Solar) Roof dead—Load(MP1) Composition Shingle 4.00 Roof Plywood 2.00 2x6 Top Chords @ 24"o.c. 1.15 Vaulted Ceiling 0.00 (Ceiling Not Vaulted) Miscellaneous 0.85 Total Roof DL(MP1) 8.0 psf DL Adjusted to 23 Degree Slope 8.7 psf Strauss Residence, Salem 2 EAH Structural Consulting 11 away; ( Lane Lexington, MA 02421 PHONE 1.978.406.8921 EA H CON3U6TIN G. Elaine@EAHstructural.com Wind Calulations Per ASCE 7-05 Components and Cladding [--'16—put --1 Wind Speed 100 mph Exposure Category B Roof Shape Gable/Hip Roof Slope 23 degrees Mean Roof Height 20 ft Building Least Width 40 ft Effective Wind Area 17.5 ft _.`_ - - — Design Win—d Pressure Calculations '7 Wind Pressure P=qh*(G-Cp) qh=0.00256*Kz*Kzt*Kd*VA2*1 (Eq_6-15) Kz(Exposure Coefficient)= 0.7 (Table 6-3) Kzt(topographic factor)= 1 (Fig.6-4) Kd(Wind Directionality Factor)= 0.85 (Table 6-4) V(Design Wind Speed)= 100 mph I Importance Factor= 1 (Table 6-1) qh= 15.23 Standoff Uplift Calculations - Zone 1 Zone 2 Zone 3 Positive GCp= -0.85 -1.45 -2.30 0.40 (Fig.6-11) Uplift Pressure= -12.95 psf -22.09 psf -35.03 psf 10.0 psf (Minimum) X Standoff Spacing= 4.00 4.00 4.00 Y Standoff Spacing= 2.75 2.75 2.75 Tributary Area= 11.00 11.00 11.00 Footing Uplift= -142 Ib -2431b -385 lb Standoff Uplift Check Maximum Design Uplift= -385 lb Standoff Uplift Capacity = 400 Ib 400 Ib capacity>385 Ib demand Therefore,OK Fastener Capacity Check--" ` T1 Fastener= 1 -5/16"dia Lag Number of Fasteners= 1 Embedment Depth= 2.5 Pullout Capacity Per Inch= 2501b Fastener Capacity= 6251b w/F.S.of 1.5= 417 lb 417 lb capacity>385 Ib demand Therefore,OK Strauss Residence, Salem 3 Y EAH Structural Consulting 11 F_gZybyQgk Lane Lexington, MA 02421 PHONE 1.978.406.8921 CAru' Elaine@EAHstructural.com Framing Check (MP1) PASS w=81 plf Dead Load 8.7 psf PV Load 4.0 psf Snow Load 28.0 psf 2x6 Top Chords @ 24"o.c. Governing Load Combo=OL+SL Member Span=9'-6" Total Load 40.7 psf ( - a Member Properties Member Size S(in A3) 1 (inA4) Lumber Sp/Gr Member Spacing 2x6 7.56 20.80 SPF#2 @ 24"o.c. _ _ - - - - -_ - _ Check Bending Stres- -s '1 Fb(psi)= fb x Cd x Cf x Cr (NDS Table 4.3.1) 875 x 1.15 x 1.3 x 1.15 Allowed Bending Stress= 1504.3 psi Maximum Moment = (wLA2)/8 = 918.088 ft# = 11017.1 in# Actual Bending Stress=(Maximum Moment)I S = 1456.9 psi Allowed>Actual--96.9%Stressed -- Therefore,OK Check Deflection Allowed Deflection(Total Load) = U180 (E=1400000 psi Per NDS) = 0.633 in Deflection Criteria Based on = Continuous Span Actual Deflection(Total Load) _ (w'LA4)I(185-E'1) = 0.213 in = U536 > U180 Therefore OK Allowed Deflection(Live Load) = U240 0.475 in Actual Deflection(Live Load) _ (WL-4)/(185'E-1) 0.147 in U776 > U240 Therefore OK Check Shear Member Area= 8.3 in42 Fv(psi)= 135 psi (NDS Table 4A) Allowed Shear = FvA = 1114 Ib Max Shear(V)=w'L/2 = 387 Ib Allowed>Actual--34.8%Stressed -- Therefore,OK Strauss Residence, Salem 4 1 Project Data Codes MA CMR 78051.00 IBC-2009,ASCE 7-05 2005 NUS,NEC-2014 nI Inverter: Enphase M250 V Load Center PV Panel: (9)LG 300 N1 V Productlon Meter Racking: ImnRidge-Flush To Roof System Rating: 2.7 kW DC-STC V Utility'Disconnect Design Factors Ground Snow Load 40 psf Map Wind Speed 100 mph Raaf 1 Azimuth: 124°N Tift:23' Solar Access:86% 9 Panels Fire Lane Bounda y BOSTONSOLAR %J ¢wx'M e.brva Iinb�Boabnaolar.ua Drawing Name Site Plan Dale November 10,2015 Utlllty Meter/Malo CLIENT INFORMATION: Drawn by MC Susan Strauss Checked by 5 Cousins Street REV# 00 Salem, MA 01970 PV - 2.0 (978)744-3300 Scale A Noted IerMWule Structure Module Specs Array o,maea xSigo -W,— Structure Type: Modular Home Model: LG 300 N1K Number of Modules: 9 aeil Rafter Size: 2x6' Length: 64.57' Total Module Weight: 337.32 Lbs 1O BaOT1"Om t{O°' Rafter Spacing: 24' Width: 39.37' Total Racking Weight: 41.96 Lbsuickmaum shingle Planning M Rafter Span: 175" Weight: 37.48 Lbs May Area: 158.88 SOFT em Lo.Prenio Moum Roof Pitch: 23° May Weight: 379.28 Lbs nnuoae.shingle. Decking Type: Plywood Racking Specs May Dead Load: 2.39 LbsISOFT 1,^ood Decuro 128 Roof Material: 1Lyr-Shingle Type: Im idge Number of Mounts: 19 m-x a-as,Ug Doll 175' Number of Floors: 2 Weight: 0.68 Lbs/Ft Load Per Mount: 19.96 Lbs en°r I MOUNTING DETAIL 310" 197 3/4" Fire lane requirement 00 E CID I. _ a O M M M 'v M M Elaine A.Huang O M MA Professional Engineer License N 49029 AX SPAN 48" 371/4" AX CANTILEVER 26" Q BWON'SOLAR 4�r CO M .A .I w.rw.Wster.l°,.ua I info®eoeronsoler.us i 7' Drawing Name Layout Date December 14,2015 CLIENT INFORNUTION: Drawn by BG 1Y Susan Strauss Checked by 5 Cousins Street REV# o0 11' Salem, MA 01970 PV _ 3.1 (978)744-3300 style Aa Noted Solar Module Enohase M250-IG Design Conditions LG 300N1 K-G4 Rated Output Power 25OW Voltage Max Pewer(VMPP) 29.5V Nominal Output Voltage 240V Annual extreme high temperature(0.4%):35"C Current Max Power(IMPP) 7.38A Nominal Output Current 1.09A 2%Average high temperature:32°C Short Circuit Current(ISC) 7.83A Imerter Efficiency 96.5% Annual extreme low temperature:-17"C Open Circuit Voltage(VOC) 36.5V Max Per 20A Branch Cir 17 Temperature at 3.5"above roof:49°C (3)#10 THWN-2 Wira Enphese Engage CeUle (1)010 THWN-2 Ground (3)#10 THWN-2 Wire (3)#10 THWN-2 Wire 1-EMT (1)#10 THWN-2 GmuM (1)#10 THWN-2 Ground 1'EMT 1-EMT Outdoor Me er p —.._.._.._..— ..�-.—..—.., O 00020553 attlng of Modulen 8 Sttlng of Motlules 8 Micoo-lnvederain Parallel:0 Miominvadem in Parellel'.9 I 100A Pnit --f.-F-:9 Pnl9ef9 `^ 15A I Main BreaFer SalaOeck-Pass r..�..—..—..— ThroWh Box I oM – --_--'1 zecA eus .J I Load Carter Hit— ML I I — 15A oPPo "EU Solar Loan Certo. ........................UEo9 a„o A Oiswnnec[ Revenuegrade 30A SMO Monilorim Symam f _-_J BOSTON wwx.b�abmolecua Irdo410wtanSole[ua DEEM,Name Line Diagram Date December 2,2015 CLIENT INFORMATION: Drawn by BG Susan Strauss Checked by 5 Cousins Street REV# 00 Salem, MA 01970 PV - 4.0 (978)744-3300 S.I. Aa Noted ALL LABELS SHALL BE OUTDOOR RATED WEATHER RESISTANT, UV AND WATER RESISTANT BASE SHEET,INKS, CAUTION AND ADHESIVES. SOLAR ELECTRIC o PV SYSTEM p LALL ETTERING LABELsSHALL BEA RED BACKGROUND WITH WHITE SYSTEMED. CONNECTED GENERATION METER PROVIALL LABELS SHALL BE REFLECTIVE MATERIAL&ETTERING. PHOTOVOLTAIC SYSTEM NOTICE WARNING DANGER DISCONNECT FOR THE UTILITY DISCONNECT IS ON O ELECTRIC SHOCK HAZARD! O O O THE OPPOSITE END OF THE DO NOT TOUCH TERMINALS DO NOT DISCONNECT UNDER LOAD UTILITY OPERATION TURN TERMINALS ON BOTH LINE AND LOAD SIDES SWITCH PRIOR TO SERVING OFF PHOTOVOLTAIC DISCONNECT HOUSE MAY BE ENERGIZED IN THE OPEN POSITION SWITCH / WARNING /N ELECTRIC SHOCK HAZARD! DO NOT TOUCH TERMINALS TERMINALS ON WARNING WARNING BOTH THE LINE AND LOAD SIDES MAY BE p PV DISCONNECT BACKFED O O ENERGIZED IN THE OPEN POSITION ELECTRIC SHOCK HAZARD! O BREAKER DO NOT REMOVE OR INTERACTIVE SOLAR PV SYSTEM RATING IF AGROUND FAULT IS INDICATED, RELOCATE CONTINUOUS OUTPUT CURRENT IOAMP NORMALLY UNGROUNDED CONDUCTORS MAYBE GROUNDED AND ENERGIZED - NORMAL OPERATING AC VOLTAGE 240 V SYSTEM INSTALLER. FOR SERVICE CALL: UTILITY DISCONNECT WARNING LABEL CAUTION WARNING O O THIS METER IS ALSO SOLAR ELECTRIC SYSTEM SERVED BY A WARNING WARNING CONNECTED PHOTOVOLTAIC SYSTEM DC SOLAR CIRCUIT INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS DC CIRCUIT LABEL OVERCURRENT DEVICE �\ UTILITY DISCONNECT LABEL BOSTON SOLAR WARNING PV SYSTEM DISCONNECT ELECTRIC SHOCK HAZARD! Draining Name mml s ma®BmIOLLabeels Page FOR UTILITY OPERATION E ISO DTOVOLNT MWXETCGNOLCTORS OF Date December,4,2015 RIIS PiroTOWLTAIC POWER SYSTEM ARE CLIENT NFGRMATIDN: p UNGROUNDED SUTMAYBEENERGRED WRH DRWII by BG RESPECT TO GROUND DUE TO LEAKAGE PATUs Susan Strauss Checked by ANOVORGROUNDFAULTs 5 Cousins Street REvx 00 DC WARNING LABEL Salem, MA 01970 PV - 5.0 (978) 744-3300 As Noted Project Data (;Odes MA CMR 78051.00 IBC-2009,ASCE 7-05 2005 NDS,NEC-2014 nI Inverter: Enphase M250 V Load Center ' W Panel: (9)LG 300 N1 V. Production Meter Reeking: ImnRiEga-Flush To Roof System Rating: 2.7 kW DC-STC V Utility Disconnect Design Factors Ground Snov Loatl 40 psf p tlS_ Wind Speeo 100 mph Roof 1 Azimuth: 124°N Tilt:23a Solar Access:86% 9 Panels Fim Lane eountla 0 h QBWONrSOLAR v .Mabnsder.us I iM @Boeloneolar.us / Drawing Name Site Plan / Date November 10,2015 Utlllty_Meter/Mnln.� CLIENT INFORMATION: Drawn by MC Susan Strauss Checketl by 5 Cousins Street REV# ]Wod Salem, MA 01970 PV - 2.0 (978)744-3300 scale As IerMMule i Structure Module Specs Array mnaas.xa wo @aa oo Structure Type: Modular Home Model: LG 300 N1K Number of Modules: 9 romeeenail rut-vw, Rafter Size: 2,6. Length: 64.57" Total Module Weight 337.32 Lbs Rafter Spacing: 24" Width: 39.37" Total Racking Weight: 41.96 Lbs umkMUM shn".rlemms 0 Rafter Span: 175" Weight: 37.48 Lbs Array Area: 158.88 SOFT ."a taW'.iss MMne shirele: Roof Pitch: 23° Array Weight: 379.28 Lbs m Decking Type: Plywood Racking Specs Array Dead Load: 2.39 LbsISQFT ly.Aw pakre 128• Roof Material: 1Lyr-Shingle Type: IronRidge Number of Mounts: 19 w a.os Las ea, Number of Floors: 2 Weight: 0.68 Lbs/Ft Load Per Mount: 19.96 Lbs 175' eflx MOUNTING DETAIL 310" 197 3/4" Fire lane requirement O ❑ ❑ rnLF 'v O M M h V t7 M Elaine A.Huang 4O M MAPMessipnal Engineer License is 49029 AX SPAN 48" 37 1/4" AX CANTILEVER 26" Q B09ONrSOLAR www.rosmnmiecw imoNaoswnsoiecue 1 7' _ Drawing Name Layout Data December 14r 2015 CLIENT INFORMATION: Drawn by BG '4 Susan Strauss Checked by 5 Cousins Street REV# 09 11' Salem, MA 01970 PV - 3.1 (978)744-3300 Scale As Noted Solar Module Enphase M250-IG Design Conditions LG 300N1K-G4 Rated Output Power 25obv Annual extreme high temperature (0.4%):35°D Voltage Max Power(VMPP) 29.5V Nominal Output Voltage 240V Current Max Power(IMPP) 7.38A Nominal Output Current 1.09A 2%Average high temperature:32"C Short Circuit Current(ISC) 7.83A Inverter Efficiency 96.5% Annual extreme low temperature:-17"C Open Circuit Voltage(VOC) 36.5V Max Per 20A Branch Cir 17 Temperature at 3.5"above roof:49°C (3)#1DTHWN2 Wire EnpM1eea Engage Cable (3)#10 T1WN-2 Wlre 11)#10THWN-2Gmund (3)#10THWN-2WIre (1)#1n T M-2 Ground 1'EMT (1)#10TH EW Gmuntl EM 1'EMT gutdoor Meter# Shingof Mod 11-a Sitlng or Motlulwfl Mivo-lnwnars in Pemllel:a Mcm-Imederee Pouliot g 1 1o" Pnl1 o1B °'� Pnl6a- "^ 15A ( Meln Breaker SoleDeck-Pau r..._....._.._ ' ThNaWh Box j 20M I i .•_••�•l 20M Boa .J I toad Career LGEMJ 15A M L.. " O 000. NEU soler Lead Cerner ?.._.._.._.._.._.._.._.._. "a125A VAIn Dlemnnaa Revenuagrale 304 Sv ch Monter,System BWONrSOLAR —loe,wn v eres I M°aS.M nsol.r. Drawing Name Line Diagram Date December 2,2015 CLIENT INFORAMTION: Drawn by BG Susan Strauss Checked by 5 Cousins Street 1REV# 00 Salem, MA 01970 PV — 4.0 (978)744-3300 Scale AS Noted ALL LABELS SHALL BE OUTDOOR RATED WEATHER RESISTANT, UV AND WATER RESISTANT BASE SHEET,INKS, CAUTION AND ADHESIVES. SOLAR ELECTRIC o PV SYSTEM Q LALL LABELS ETTERING SHALL EDA RED BACKGROUND WITH WHITE SYSTEM CONNECTED GENERATION METER PROVALL LABELS SHALL BE REFLECTIVE MA TERIALILETTERING. PHOTOVOLTAIC SYSTEM NOTICE WARNING DANGER DISCONNECT FOR THE UTILITY DISCONNECT IS ON 0 ELECTRIC SHOCK HAZARD! O o ER LOAD 0 UTILITY OPERATION THE OPPOSITE END OF THE DO NOT TOUCH TERMINALS OO NOFF OTDISCONOLTAICNECT DISCONNECT TERMINALS ON BOTH LINE AND LOAD SIDES TURN SWITCH PRIOR SER CONNECT HOUSE MAY BE ENERGIZED IN THE OPEN POSITION SWITCH PRIOR TO SERVING / WARNING /N ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS.TERMINALS ON WARNING WARNING BOTH THE LINE AND LOAD SIDES MAY BE Q PV DISCONNECT BACKFED o ENERGIZED IN THE OPEN POSITION 0 ELECTRIC SHOCK HAZARD.I 0 BREAKER DO NOT REMOVE OR INTERACTIVE SOLAR PV SYSTEM RATING IF A GROUND FAULT IS INDICATED, NORMALL Y UNGROUNDED CONDUCT ORS RELOCATE CONTINUOUS OUTPUT CURRENT IOAMP MAYBE GROUNDED AND ENERGIZED NORMAL OPERATING AC VOLTAGE 240V SYSTEM INSTALLER. FOR SERVICE CALL' UTILITY DISCONNECT WARNING LABEL CAUTION WARNING Q 0 THIS METER IS ALSO SOLAR ELECTRIC SYSTEM SERVED BYA WARNING WARNING CONNECTED PHOTOVOLTAIC SYSTEM DC SOLAR CIRCUIT INVERTERTPUT CONNNECTNECTION DO NOT RELOCATE THIS DC CIRCUIT LABEL OVERCURRENT DEVICE UTILITY DISCONNECT LABEL BOSTONSOLARWARNING 0 olar PV SYSTEM DISCONNECT ELECTRIC SHOCK HAZARD! a•mowLcu= imA®aowLabelss brewing Name Labels Page THE DIRECT CURRENTCIRGUIT CONDUCTORS OF Date December 14,2015 FOR UTILITY OPERATION THIS PHOTDroRAICRDWER SYSTEM ARE CLIENT INFORMATION: UNSR UNDEDBUTMRYaE ENERGRED WITH D(8MT by BG Q RESPECTTOGROUNDDUETOLEAWIGEPATHS ANDVRGROUNOFAULTS Susan Strauss Ch¢ek¢tl by 5 Cousins Street REvu 00 DC WARNING LABEL Salem, MA 01970 PV - 5.0 (978)744-3300 As Noted LG Life's Good ■ ■ LG Neo ii r� LG's new module,Ni 2 Black,adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires *� Acea 60 cell to enhance power output and reliability.Nik demonstrates LG's efforts to increase customer's values B E ♦ E oveovaooucT eONr"^ us beyond efficiency.It features enhanced warranty,durability, Intertek performance under real environment,and aesthetic design "�`�s an000�oa,m M�a�":"'s suitable for roofs. Enhanced Performance Warranty �'•II'� High Power Output tiitllll7liV LG Ni 2 has an enhanced performance warranty. �7�7777�7� Compared with previous models,the LG Nei 2 The annual degradation has fallen from-0.7%/yr to has been designed to significantly enhance its output -0.6%/yr.Even after 25 years,the cell guarantees 2.4%p efficiency,thereby making it efficient even in limited space. more output than the previous NeON""modules. Aesthetic Roof ® Outstanding Durability IIT LG NeONr""2 has been designed with aesthetics in mind, With its newly reinforced frame design,LG has extended �IIIf11I11111 thinner wires that appear all black at a distance.The the warranty of the Ni 2 for an additional 2 years. product may increase the value of a property with its Additionally,LG NeDi 2 can endure a front loadup to modern design. 6000 Pa,and a rear load up to 5400 Pa. ; Better Performance on a Sunny Day IRAL Cell Structure LG Ni2 now performs better on sunny days thanks !!!!!! The rear of the cell used in LG Ni2 will contribute to to its improved temperature coefficiency. generation,just like the front,the light beam reflected from N the rear of the module is reabsorbed to generate a great amount of additional power. About LG Electronics LG Electronics Is a global player who has been committed to expanding its capacity,based on solar energy business as its future growth engine.We embarked on a solar energy source research program In 1985,supported by LG Groups rich experience in semi-conductoq i chemistry,and materials industry We successfully released the first Mona Xv series to the market in 2010,which were exported to 32 countries in the following 2 years,thereafter In 2013,Nei(previously known as Mono X®NeONj won"Intersuar Award';which proved LG is the leader of Innovation in the industry LG NeON z clack f t Mechanical Properties Electrical Properties(STC�) Cells 5 u 10 300 W Cell Vendor LG MPP Voltage(Vmpp) 32.5 Cell Type Monocrystalline/N-type MPP Current(Impp) 9.26 Cell Dimensions 156.75 x 156.75 mm/6 x 6 inch Open Circuit Voltage(Vac) 39.7 a of Busbar 12(Multi Wire Busher)0 Short Circuit Current(Isc) 9.70 Dimensions(L x W x H) 1640 x 1000 x 40 mm Module Efficiency(%) 18.3 64.57 x 39.37 x 1.57 inch Operating Temperature(°C) -40-,90 Front Load 6000 Pa/125 psf } Maximum System Voltage(V) 1000 Rear Load 5400 PA/113 psf QF Maximum Series Fuse Rating(A) 20 Weight 17.0 at 0.5 kg/37.48 t 1.1 Iles Power Tolerance(%) 0-t3 Connector Type MC4,MC4 Compatible,IP67 •STC standard Test Condivion).iradiante 1000 W/rd,ModaleTempeamre 25•c,AM 1.5 -The nameplate power outputsmeasured and determined by US socnoma ata sole and absolute discretion Junction Box IP67 with 3Bypass Diodes Th • e typical choosei module erfi<er,M 200 W/m mlatmnto 1000 vv is 30%. Length of Cables 2 x 1000 mm/2 x 39.37 inch Glass High Transmission Tempered Glass Electrical Properties(NOCT*) Frame Anodized Aluminum 300 W Certifications and Warranty Maximum Power(Pmpp) 218 MPP Voltage(Vmpp) 29.5 Certifications(In Progress) IEC 61215,IEC 617301 A 1703, MPP Current(Impp) 7.38 ISO 9001,IEC 62716(Ammonia Test), Open Circuit Voltage(Voc) 36.5 IEC 61701(Salt Mist Corrosion Test) Short Circuit Current(Ise) 7.83 Module Fire Performance Type 2(UL 1703) •NOCT(Nombalopeaeng cell Temperature)Irresolute 800 w/nc2,ambient temperature 20°C.wmdspeed l m/s Product Warranty 12 years O Output warranty of Pmax Linear warranty* Dimensions(mm/in) (measurement Tolerance t 3%) •1)1,1 y...98%,2)After 2nd yea,.0.6%p annual recall 3)63.6%par 25 years Temperature Coefficients T gL ] NOCT 46±3°C ° Par -0.38%/`C� ' ,was °,.,. ,.°,,,. Vac -0.28%/°C. oa... o<...a s aM,. :.°.....a... Isc 0.02%/°C we— Characteristic Curves 1ic-- __,w. j,neoold .....w,...,..4 11 r.I 600 fi00W ww.gnscs.I ass. 300W i..re x F Is .e•m IF / o.aa sIs.0 .00 , 111.. 1.,. xs.00 xo.ao se.po 4o.ao .s.w s i .. 1 a, < 140 � s 'p s 1x0Its -. — - 5 as 40 _____ _ _ ..._..___ ...._........._. to we A o lis so xs m •The distance between the center of the moonting/grounding holes. ® �� North America Solar Business Team produce specifications are subject to change without notice. 1�Q LG Electronics LLS.A.Inc DS-N2-60-K-G-F-EN-50427 +�'� ❑fes Good 1000 Sylvan Ave,Englewood Cliffs,N107632 Copyright©2015 LG Electronics.All rights reserved. Innovation for a Better life Contact:Ig.solar@Igatom 01/04/2015 www.lgsolarusacom �1J Enphase Microinverters Enphase® M250 0 0 a(( C ^ . r = The Enphase Energy Microinverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation, and management of solar power systems. The Enphase System includes the microinverter, the Envoy Communications Gateway;'"and Enlighten® Enphase's monitoring and analysis software. PRODUCTIVE SMART -Optimised for higher-power modules - Quick and simple design, installation, - Maximises energy production and management - Minimises impact of shading, dust, and debris -24/7 monitoring and analysis RELIABLE SAFE -4th-generation product - Extra low-voltage DC reduces fire risk -More than one million hours of testing - No single point of system failure -System availability greater than 99.8% - Easy installation with Engage Cable [e] enphase® E E N E R G Y Enphase®M25O Microinverter//DATA INPUT DATA(DC) M250-60-230-S22 Recommended input power(STC) 210-310 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22 V/48 V Max DC short circuit current 15 A Max input current 10A OUTPUT DATA(AC) Peak output power 258 W Rated output power 250 W Rated output current 1.09 A Nominal voltage 230 V Nominal frequency 50.0 Hz Power factor >0.95 Maximum units per 20 A branch circuit 14(Ph+N),42(3Ph+N) Maximum units per cable section 14(Ph+N),24(3Ph+N) EFFICIENCY EN 50530(EU)efficiency 95.7% Static MPPT efficiency(weighted,reference EN50530) 99.6% Dynamic MPPT efficiency(fast irradiation changes, 99.3% reference EN50530) Night time power consumption 0.055 W MECHANICAL DATA External operating temperature range(ambient) -400C to+650C Internal operating temperature range -400C to+850C Enclosure environmental rating Outdoor-IP67 . Connector type MC4 Dimensions(WxHxD) 179 mm x 217 mm x 28 mm(with bracket) Weight 1.66 kg Cooling Natural convection-No fans - FEATURES Compatibility Compatible with 60-cell PV modules. Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Transformer design High frequency transformers,galvanically isolated Compliance AS4777,C10/11,CEI_0-21,EN50438,EN62109-1,EN62109-2, ERDF-NOI-RES_13E_V5,G59/2,G83/2, VDE-0126-1-1 +A1,VIDE AR-N 4105 To learn more about Enphase microinverter technology, [e] enphase` visit enphase.com/au. E N E R c v 0 2014 Enphase Energy.Al rights resented.All trademarks or brands in this document are registered by their respective owner. /ld IRON RIDGE Roof Mount System Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. Fa available in most states. ® Class A Fire Rating Design Software Certified to maintain the fire resistance FQ Online tool generates a complete bill of rating of the existing roof. materials in minutes. Integrated Grounding 20 Year Warranty UL 2703 system eliminates separate Twice the protection offered by module grounding components. 191 competitors. — — XR Rails XR10 Rail XR100 Rail XR1000 Rail Internal Splices Q ---------------- A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-tapping screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear anodized finish • Clear& black anod. finish • Clear anodized finish • Grounding Straps offered Attachments FlashFoot Slotted L-Feet Standoffs Tilt Legs Anchor, flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware • High-friction serrated face • Works with vent flashing • Attaches directly to rail • IBC& IRC compliant • Heavy-duty profile shape • Ships pre-assembled • Ships with all hardware • Certified with XR Rails • Clear& black anod.finish • Lengths from 3"to 9" • Fixed and adjustable — Clamps & Grounding End Clamps Grounding Mid Clamps T-Bolt Grounding Lugs Q Accessories Low- Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish & black anod. • Parallel bonding T-bolt • Easy top-slot mounting • Snap-in Wire Clips • Sizes from 1.22"to 2.3" • Reusable up to 10 times • Eliminates pre-drilling • Perfected End Caps • Optional Under Clamps • Mill& black stainless • Swivels in any direction • UV-protected polymer Free Resources Design Assistant A NABCEP Certified 71raining Go from rough layout to fully 1O V, Earn free continuing education credits, engineered system. For free. �. : while learning more about our systems. — Go to IronRidge.com/rm ♦ Go to IronRidge.com/training o , :,, " 0 12.19.15 Cousins St. Condo Association 3-11 Cousins St. Salem, MA 01970 To Whom It May Concern: The Cousins St. Condo Association has approved the installation of solar panels by owners of the individual units. At present the owners of#5 and#11 are in the process of having solar panels installed on their unit's roof hi the future, if other owners choose to install solar panels on their individual roofs, they will be allowed to do so. Sincerely, Cousins St. Condo Association Trustees Betty Bouchard Barbara R. Kelley Susan Strauss