Loading...
5 1/2 BARR ST - BPA-16-922 SOLAR z G2- The zThe Commonwealth of Massachusetts Board of Building Regulations and Standards CITY OF P Massachusetts State Building Code, 780 CMR 2M SE —2 S40 53 Revised Mar 2011 Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling - This Section For Official e.Only - Building,PermitNumber: -Date pplied: 1 - Building Official(Print Name) _ Signature Dat SECTION 1: SITE INFORMATION ' Ll Property Address: 1.2 Assessors Map& Parcel Numbers 5 1/2 Barr Street 26 0264 I.I a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: William Brauner Salem MA 01970 Name(Print) City,State,ZIP 5 1/2 Barr Street 781-632-9466 No.and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repaus(s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units Other IN Specify:Solar Installation Brief Description of Proposed Work: Roof mount Grid Tied PV Solar Installation 10-265W Trina Panels, 10-Enohase M215 Micro Inverters SECTION 4:ESTIMATED CONSTRUCTION COSTS Estimated Costs: Item Official Use Only (Labor and Materials) 1.Building $ 9,995 1. Building Permit Fee: $. Indicate how fee is determined: ❑Standard City/Town Application Fee ' 2.Electrical $ 4 000 ❑Total Project Cost (item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $' 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Total All Fees: $ Supression) Check No. - Check Amount: Cash Amount: 6.Total Project Cost: $ 13,995 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-108214 4/2/18 Eric Chartrand License Number Expiration Date Name of CSL Holder Lis[CSL Type(see below) U 27 Sanborn Street No.and Street Type Description FitchburgMA 01420 U Unrestricted(Buildings u to 35,000 cu.11.)R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 978-652-2680 ericchartrand@endlessmtnsolar.com 1 I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 174479 1/28/17 Endless Energy HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 288 Kidder Street imlaskowski()endlessmtnsolar.com No.and Street Email address Wilkes Barre PA 18702 570-820-5990 Ci /Town, State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. - II' Signed Affidavit Attached? Yes .......... IN No...........❑ - SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize Endless Energy to act on /mmyy behalf,in all matters relative to work authorized by this building permit application. PrintV'2� WI ,/lQrh �//�v/I t/1— Owner' a(Ele tronic Signature) Date SECTION 7b:OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below,1 hereby attest under the pains and penalties of perjury that all of the information cwntaine in this application is true and accurate to the best of my knowledge and understanding. �'1Z116, p2g,owneCs or Authorized Agent's Name(Electronic Signature) Date NOTES:' 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. I42A. Other important information on the HIC Program can be found at www.mass.eov/oca Information on the Construction Supervisor License can be found at www.mass.eov/dpss 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" i TGL ENGINEERING, INC. 251 Mundy Street, Suite C Wilkes-Barre,PA 18702 (570)208-7233 www.LEldesigns.biz August 22, 2016 Jim Laskowski Endless Mountain Solar Services 288 Kidder Street Wilkes-Barre, PA 18702 Re: Branner Residence,51/2 Barr Street,Salem,MA Dear Mr. Laskowski, As you requested, I have performed a structural evaluation of the roof framing at the above referenced residence. It is my understanding that solar panels weighing approximately 4 pounds per square foot(psf) are proposed to be installed on the southwest face of the rear low-slope dormer. Per your inspection, pictures and layout plan, the dormer roof is framed with 2x10 joists spaced at 16" on center and spanning 13' horizontally. The joists slope at a L 12 pitch. The Massachusetts Amendment to the 2009 International Residential Building Code snow chart indicates the design ground snow load in Salem is 40 pounds per square foot(psf), which translates to a design roof snow load of 28 psf. The roof dead load of the joists, assumed batt insulation, sheathing and EPDM roof is approximately 10 psf and the addition of the solar panels results in a total dead load of 14 psf. For this evaluation, it was assumed the rafters are typical spruce-pine-fir no. 2 or better. Our calculations indicate thejoists are stressed to 53% of their capacity under the full snow load, existing roof dead load and proposed solar panel weight.Therefore it is my opinion the solar panels may be installed in the proposed areas without reinforcement of the existing joists. No other framing areas were included in the scope of this evaluation. The above opinion is based on the above information provided by you and the assumption that the framing members and connections are in sound condition. Any deviations from the above criteria discovered during the course of the work must be immediately brought to our attention. Please call me with any questions. Thomas Leonard,P.E. ASH OF 4f4S President b THOMAS G. s� LEONARD v STRUCTURAL No.49749 "v FFG/STS S/ONAL 120V EnP ememei Communications Gabler GEC Connected Conneamn Gateway to Rails with BRANCH CIRCUIT to Router / Weeblu eex>mse � 9 i /{ B IT I C D Junction 11 r Sox Neutral ? 1 O 2P 20A Enphase Cable UPTO V M215-S PER TERMINATION CAP Ground NoteSolar is line(top) 6 AWG GEC #12 Conducrors BRANCH CIRCUIT ON CABLE END and Utility is load(bottom) eiacx-u 6 AWG GEC Red-L2 While-Neutral Green-Ground Existing Service Panel RZ 10 �d r • I 4 t" Branch A 10 Enphase M215 Microinverters Point of Interconnection 1 1"Sch 80 PVC conduit. (2)Hot and(1)Neutral r,* 10 Trina 265W Modules 2 Pole 20A Breaker,to be installed conductors: 10 AWG,THWN,90C. (1)Ground 9A/240V furthest from main breaker conductor: 10 AWG,THWN,90C. Al Existing Utility B Existing Main Service Panel:200A Murray Proposed AC Disconnect: Proposed REC SYSTEM SPECIFICATIONS Meter,Proposed LC3040B1200 with 200A Main Breaker 30A,Siemens ITE GN F321 R, Meter: Exterior near Net Meter Exterior near utility meter utility meter DC POWER (KW): 2.65 AC POWER(KW): 2.15 CUSTOMER: Holly Brauner COMPANY: Endless Energy AC VOLTAGE(V): 240 DBA and William Brauner 184 Cedar Hill St Endless AC CURRENT(A): 9 5 1/2 Barr St Marlborough, MA 01752 AC DISCONNECT SIZE: 30A Salem, MA 01970 DRAWN BY: Shawn Corble Energy MODULE TYPE/QTY: Trina 265W/ 10 781-632-9466 Work y INVERTER TYPE/QTY: Enphase M215/ 10 ro 3 B I Note:Cut PVC —all Front of vent pipe to 2' House height 228* Azimuth .O 5" Pitch � Existing Service Panel 3' Fire M Set-Back Proposed AC Disco Existing Utility Meter SYSTEM SPECIFICATIONS `S Proposed REC Meter Proposed Net Meter DC POWER(KW): 2.65 AC POWER(KW): 2.15 CUSTOMER: Holly Brauner COMPANY: Endless Energy L(onS ALE: AC VOLTAGE (V): 240 DBA and William Brauner 184 Cedar Hill St Endless1:55 AC CURRENT(A): 9 5 1/2 Barr St Marlborough, MA 01752 x17 paper) AC DISCONNECT SIZE: 30A 781-632-9466 Work DRAWN BY: Shawn Corbley /� EnergyEW:TOP INVERTER TYPE/CITY: Enph se 2150/ 10 O URI _ A RACr (Patent Pending) solarldountTmshown Flush mounted I �� in landscape (horizontal) mode ; i� i soLARMoumTs are the easiest, fastest, and safest way to install a PV array on the roof of virtually any building. Universal -Any 64 Watt or larger, framed PV module Bi-Directional Mounting - Mount your modules in sold in North America can be mounted using landscape (horizontal) mode, as shown above, or in SolarMount. (See PV Module Compatibility List on the portrait (vertical) mode. If you have limited roof back page.) space, you can even use both orientations in a single installation. Roof Top Assembly- Because of its "top down" clamps, SolarMounts are ideal for use with the new Meets Building Code Requirements-Whether the "plug 'n play" PV modules. An entire array can be roof is pitched or flat, and regardless of the roofing fully assembled and wired where they'll be installed — material, SolarMount will securely attach your PV array on the roof. This eliminates the awkward hazard of to your roof in compliance with U.5 Building Codes. lifting partially assembled arrays to the roof, and then (See "Building Code Compliance" on the back page.) mounting and adjusting them on their footings. Quick and Easy Installation-Continuous, dual slotted (See inside for details)» SolarMount rails provide the ultimate in adjustability. No more re-drilling holes, or repositioning footings.