HERS RATING @ APT 1 lbe a=-.
Home Energy Rating Certificate Rating Date: 2019-04-23 We+ •
Final Report Registry ID:055306194 Hii•
i I
Ekotrope ID: YdxArwzv
HERS® Index Score: Annual Savings Home:
Your home's HERS score is a relative performan 344 Salem,MA 01970 13 Meadow St APT 1
The lower the number,the more energy efficier II ay
home.To learn more,visit www.hersindex.com
5
.Relative to an average U.S.home Builder:
Torgerson
Your Home's Estimated Energy Use: This home meets or exceeds the
Use[MBtu] Annual Cost criteria of the following:
Heating 16.2 $317 2015 International Energy Conservation Code
Cooling 0.4 522
Hot Water 7.0 $133
Lights/Appliances 13.4 $613
Service Charges 5190
Generation(e.g.Solar) 0.0 $0
HERS Index Home Feature SthiIrAary: $1,275 Rating Completed by:
"•""^"n Home Type: Apartment,end unit Energy Rater:lan Rex
,N, Model: N/A
t.ntmg Community: N/A RESNETID:1454792
Homes ,„
Conditioned Floor Area: 819 so.ft.
Number of Bedrooms. 2 Rating Company:The Energy Hound
Reference tome o Primary Heating System: Furnace•Natural Gas•92.1 AFUE PO Box 177,Kittery Point,ME 03905
Primary Cooling System: Air Conditioner•Electric•13 SEER 978-233-1433
11,1
Primary Water Heating: Water Heater•Natural Gas•0.93 Energy Factor70
House Tightness: 326 CFMSO 0.51 ACH50; Rating Providar.Energy Raters of Massachusetts w,
Ventilation: !1.0 CFh1.5.5 Watts 2 Woodlawn Street Amesbury,MA 01913 - i
rha xom. Duct Leakage to Outside: 0 CFM25(0'100 s.fl 978-270-3911 } ..'o " f
ro Above Grade Walls: R •„-21 •4• ,„ �•
Ceiling: Adiabatic,R•30
to
z"°tX orne a Window Type: U.Value:0.31,SHGC:0.23
...ohm Foundation Walls: N.A
IECC 2015 Label
13 Meadow St APT 1
Ekotrope RATER - Version: 3.1.1.2157
HERS® Index Score: 51
Building Envelope Specs
Ceiling: R-30
Above Grade Walls: R-21
Foundation Walls: N/A
Exposed Floor: R-30
Slab: N/A
Infiltration: 326 CFM50 (2.51 ACH50)
Duct Insulation: R-6
Duct Leakage: 0 CFM @ 25Pa
Window& Door Specs
U-Value: 0.31, SHGC: 0.23
Door: R-3
Mechanical Equipment Specs
Heating: Furnace • Natural Gas • 92.1 AFUE
Cooling: Air Conditioner • Electric • 13 SEER
Hot Water: Water Heater • Natural Gas • 0.93
Energy Factor
Builder or Design Professional
Signature.
Building Summaryt
The:,'
Ell a
t
Property organization Inspection Status r :
13 Meadov, II St APT 1 Tne Energy Hound 2019-04-23 I
Salem MA 01970 978-233-1433 Rater ID(RTIN) 1454792
Ian Rex RESNE' Registered(Confirmed)
ocer common under adiabat
SALE Meadov.St 13.1 Builder
Torgerson
General Building Information
Number Of Bedrooms 2
Number Of Floors 1
Conditioned Floor Area[sq ft] 819
Unconditioned attached garage? No
Conditioned Volume(cu ft] 7 781
Total Units in Building 2
Residence Type Apartment end unit
Floor Number 1
Model
Community
Climate Zone 5A
Basement Wall
None Present
Basement Wall Library List
None Present
Slab
None Present
Slab Library List
None Present
Framed Floor
Name Library type Carpet R Floor Grade Surface Area Location
,Adiabatic ADIAE FG R3C=r _ Abctie Grade 819 C sq h Conditioned Space
Adiabatic i
1
Building Summary s._
The_- '
Property Organization Inspection Status ��
13 Meaoo,+,St APT 1 The Energy Hound 2019-04-23 ilia
Safer, MA 01970 978-233-1433 Rater ID IRTIN) 1454792
fan Rex RESNET Registered(Confirmed)
over common under adiabat
SALE MeadowSt 13-1 Builder
Torgerson
Framed Floor Library List
Name Effective R-value
ADIAB FG R30 FmrGyp 27 29
Rim Joist
None Present
Rim Joist Library List
None Present
Wall
Name Library Type Surface Color Surface Area Location
Adiabatic FG3 R13 ADIAB Medium 257 0 sq R Conditioned Space(Adiabatic)
Ambiant DFg2 5 Hi R21 ivy/d Medium 1 216 0 sq ft Exposed Exterior
Wall Library List
Name Effective R-value
FG3 R13 ADIAB 10 047
LDFg2 5'Hi R21 Gyp.Wd 16 736
Glazing
Name Library Type Wall Assignment Basement Wenit Overhang Depth Overhang FtT oTo OverhanBo Ftto Tm Orientation Surface Area
A 2A 4 0 31:.'. AmDlant 0 Northwest 24 0 sq ft
B 3 2 0 1 9 31 2_ Ambiani1 0 0 .__.._.-Southwest 12 0 sq ft
2
Building Summary
TLe_ , .
Property Organization Inspection Status V•~t'1
13 Meadow St APT 1 The Energy hound 2019-04-23 H i ( i
Saiem MA 01970 978-233-1433 Rater ID(RTIN r 1454792
ian Rex RESNET Registered LConfrrmedl
over common under adiabat
SALE Meador.St 13.1 'Subtler
Torgerson
Name Library Type Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area
Assignment Top Bottom
Sack A 2 2 040 31 23 Ambiant 0 0 Southeast 16 0 sq rt
Front or obii.oF_Arg- Ambiant 0 _ 0 Northwest 8 0 sq Ti
Vinyl
eft C 1 2 0 3.0 31 23 Ambiant 0 0 Northeast 6 0 sq ft
Right A 4 2 0 40 31 23 Ambiant 0 C 0 Southwest 32.0 sq ri
Glazing Library List
Name Shgc U•factOr
s123 -23 0310
Doi_^E Arg-yin -_ 0 45 0 330
Skylight
None Present
Skylight Library List
None Present
Opaque Door
Name Library'type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location
Assignment Absorptance
=,i n• ::or R-? Ambiant! 0 5 0 7 f medium 20 0 sq ft Exposed Extenor
Opaque Door Library List
Name Effective U•factor
Door R-3
3
Building Summary
The- ..
LB W Property Organization Inspection Status 6••-
13 Meadow St APT 1 The Energy Hound 2019-04-23 H r( i.1
Salem.MA 01970 976.233-1433 Rate(ID IRTIN) 1454792
Ian Rex RESNET Registered(Confirmed)
over common under adiabat
SALE MeadowSt 13-1 Builder
Torgerson
Roof Insulation
Name b Ty Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location
Isl.] Tiles
FGBatt>Adiabatir ADIAE LDF Li R30 Gvprary Finpe 819 No Medium 819 0 54 R Conditioned Space
Adiabatic)
Roof insulation Library List
Name Has Radiant Barrier Effective R•value
ADIAE_DF R30 No 28 16
Gyp'Fin
Whole House Infiltration
Infiltration Measurement Type Shelter Class
326 CFM at 50 Pa Bloa.er-dooi tested 4
Mechanical Ventilation
Ventilation Type Ventilation Rate(Cubic Feet Operational hours per day Fan Watts Runs once every three Energy Recovery Percent
Minute) hours
Exhaust Onll 24 :5 Yes C
Lighting
Interior Fluorescent %Interior LED Lighting %Exterior Fluorescent °%Exterior LED Lighting %Garage Fluorescent %Garage LED Lighting
Lighting Lighting Lighting
e 1r- 0 1";0 0 1pP
Onsite Generation
None Present
4
Building Summary
.cyT�hea:-C: -_..-
Property Organization Inspection Status Lu if'
13 Meadow'Sr API 1 Tne Energy Hound 2019-04.23 H i't t
Salem.MA 01970 978-233-1433 Rater ID cRTIN) 1454792
Ian Rex RESNET Registered(Confirmed)
over common under adiaoat
SALE MeadowSt 13.1 Builder
Torgerson
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Name Library type Heating Percent Load Cooking Percent Load Hot Water Percent Load
Air conditioner 2i AC 4A7A3030H1 13 25s AH 100°u
4TXCB003DS3 29Ko c x AMERICAN
=uei-fired air GP PG92SCS3004OA 92 111e 37Ko 100°° 0°n
distriOunOn i 1; 385e Pane a 7126237
Water Heating,3i wGi RU160i 93%Rinnai iREU- 0°° 0a, 1 ;.,
N2S30FF-LISin 10595452
Equipment Type: AC 4A7A3030H1 13.25s AH 4TXCB003DS3
29Ko F x AMERICAN STANDARD #9152292
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSC(Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity[kBturhj 33 6
5
Building Summary -
The-'-�.
Property Organization Inspection Status En
13 Meadov,St APT 1 Tile Energy Hound 2019-04-23 gU i I I
Salem.MA 01970 978-233-1433 Rater ID(RTtN) 1454792
Ian Rex RESNET Registered(Confirmed)
over common under adiabat
SALE MeadowSt 13-1 Bulder
Torgerson
Equipment Type: GF PG92SCS30040A 92.1% 37Ko 385e Payne
# 7126237
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSC(Single Speed)
Heating Efficiency 92 1 AFUE
Heating Capacity tkBtufh] 37
Use default EAE No
EAE[kWh] 385
Equipment Type: wGi RU1601 93% Rinnal (REU-N2530FF-US) #
10595452
Fuel Type Natural Gas
Distribution Type Hydronic Delivery
Hot Water Efficiency 0 93 Energy Factor
Tankless 7 Yes
6
Building Summary -"�
The,
En' ;
Property Organization Inspection Status
13 Meadow St APT 1 -the Energy Hound 2019-04-23 W f f
Salem.MA 01970 978-233-1433 Rater ID IRTINi 1454792
Ian Rex RESNET Registered(Confirmedi
over common.under adiabat
SALE MeadoviSt 13-1 Bulder
Torgerson
Distribution System
Distribution Type Forced Air
Heating Equipment Fuel-fired air distnbution(1)
Cooling Equipment Air conditioner(2)
Sq Feet Served 819
#Return Grilles 4
Supply Duct R Value 6
Return Duct R Value 6
Supply Duct Area[sq ft.] 221 13
Return Duct Area[sq ft.] 163 8
Duct Leakage to Outdoors(CFM25) 0
Total Leakage 40
Total Leakage Duct Test Conditions Post-Construction
Use Default Flow Rate Yes
Duct 1
Duct Location Conditioned Space
Percent Supply Area 100
Percent Return Area 100
Duct 2
Duct Location Attic(well vented)
Percent Supply Area 0
Percent Return Area 0
Duct 3
Duct Location Conditioned Space
Percent Supply Area 0
Percent Return Area 0
Duct 4
Duct Location Conditioned Space
Percent Supply Area 0
Percent Return Area 0
Duct 5
Duct Location Conditioned Space
Percent Supply Area 0
Percent Return Area 0
Duct 6
Duct Location Conditioned Space
Percent Supply Area 0
Percent Return Area 0
Ceiling Fan
Has Ceiling Fan Yes
Cfm Per Watt 70 4
Water Distribution
Water Fixture Type Standard
Use Default Hot Water Pipe Length No
Hot Water Pipe Length[ft] 23
At Least R3 Pipe insulation? Yes
Hot Water Recirculation System? No
Recirculation System Pipe Loop Length[ft] 0
Drain Water Heat Recovery? No
•
Building Summary The
Property Organization Inspection Status Ellie:
13 meadow St APT I The Energy Hound 2019-04.23 HOUn
Saieir; MA 01970 578-233-1433 Rater ID(RTIN) 1454792
Ian Rex RESNET Registered(Confirmed)
over common under adiaoat
SALE MeadowSt 13-1 Budder
Torgerson
s
Clothes Dryer
Fuel Type Electric
Cef 3.61
Field Utilization Timer Controls
Clothes Washer
Label Energy Rating 79 kWh/Year
Electric Rate $0 12;kWh
Annual Gas Cost $6 00
Gas Rate $1.09 Therm
Capacity 1.5
met 1 15
Appliances and Controls '`
Programmable thermostat? Yes
Dishwasher Size Standard
Dishwasher Efficiency 268 kWh
RangeiOven Fuel Natural Gas
Convection Oven? No
induction Range? No
Refrigerator Consumption 672 kWh/Year
Notes
Warnings Verified for...
Exhaust Fan energy
Washer:Dryer energy
washer 1 15 1 5 79
dyer 3 61
8
RESNET HOME ENERGY
RATING Standard Disclosures �*
Ht � t �
For home(s) located at: 13 Meadow St APT 1, Salem, MA
Check the applicable disclosure(s) in accordance with the
instructions on the reverse of this page:
4'1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home.
2. In addition to the rating,the Rater or the Rater's employer has also provided the following consulting services
for this home:
A. Mechanical system design
B. Moisture control or indoor air quality consulting
C. Performance testing and/or commissioning other than required for the rating itself
D. Training for sales or construction personnel
E. Other(specify)
j 3. The Rater or the Rater's employer is:
A. The seller of this home or their agent
B. The mortgagor for some portion of the financed payments on this home
jj C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home
{ 4. The Rater or Rater's employer is a supplier or installer of products, which may include:
Products Installed in this home by OR is in the business of
HVAC systems ; Rater ( ;Employer j( Rater Vi,Employer
Thermal insulation systems !Rater I ;Employer ! 'Rater !Employer
Air sealing of envelope or duct systems I !Rater rEmployer ( Rater Employer
Energy efficient appliances !Rater II Employer 1 ;Rater i ;Employer
Construction (builder, developer, construction contractor, etc) !Rater 1' '.Employer ! 'Rater 1 !Employer
Other(specify): )Rater ! ;Employer I !Rater ;Employer
5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for
Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy
Services Network (RESNET). Rater Certification #: 1454792
Name: Ian Rex Signature:
Organization: The Energy Hound Digitally signed: 4/24/19 at 1:45 PM
I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating
Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating
Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality
control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at
http://resnet.us/standards/RESNET_Mortgage_Industry_National_HERS_Standards.pdf
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
RESNET Form 03001-2 - Amended April 24, 2007
Builder Affidavit
Property Organization Inspection Status gQ l
13 Meadow St APT 1 The Energy Hound 2019-04-23 II
Salem, MA 01970 978-233-1433 Rater ID (RTIN): 1454792
Ian Rex RESNET Registered
over common, under adiabat (Confirmed)
SALE MeadowSt 13-1 Builder
Torgerson
Important Notice to Builder
Builder affirms in this affidavit that all building characteristics described in the Building Summary Report accurately reflect this
New Home. Builder agrees to allow the Home Energy Rating System (HERS) Provider and/or Rater to verify building
characteristics of this New Home fully at the HERS Rater/Provider's discretion. The HERS Provider and Rater do not create or
imply any duty or obligations to Builder or any subsequent owner. Builder is responsible for taking any actions necessary to
protect Builder's interest There is no guarantee or warranty whatsoever expressed or implied from the HERS Provider or
Rater.
HERS®Index Score:51
Builder Name: Torgerson Builder Signature:
Name: Ian Rex Signature:
Organization: The Energy Hound Digitally signed: 4/24/19 at 1:45 PM
Ekotrope RATER-Version 3.1.1.2157
results are based on data entered b;Ekotrope users Ekotrope discaims all liabaity for the information shown on this report.