Loading...
UTS Job 23418 Report 33 Compressive Strength Report - Concrete 08-21-2019-Page 1 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 08-21-2019Compressive Strength Report - Concrete Report No.33 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.Aggregate Industries ALL FIELD TESTS DONE ACCORDING TO ASTM:C-172 C-31 C-143 C-1064 C-39 C-1231ALL COMPRESSIVE STRENGTH TESTS DONE ACCORDING TO ASTM: CLASS CONCRETE:3000# 3/4"No. Of Sets:1 10CUBIC YARDS: SET 1 LOCATION:Pier Footings Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type H001 4.00 x 8.00 12.57 Good 08/21/19 08/28/19 7 30,000 2,390 1 H002 4.00 x 8.00 12.57 Good 08/21/19 09/04/19 14 48,000 3,820 1 H003 4 x 8 12.57 Good 08/21/19 09/18/19 28 H004 4 x 8 12.57 Good 08/21/19 09/18/19 28 H005 4 x 8 12.57 Good 08/21/19 09/18/19 28 H006 4.00 x 8.00 12.57 Good 08/21/19 08/29/19 8 34,000 2,700 2 H007 4 x 8 12.57 Good 08/21/19 10/16/19 56 H008 4 x 8 12.57 Good 08/21/19 10/16/19 56 Slump (in.)4 1/2 Air Temp. (F.)75 Conc Temp (F)84 Truck No.239 Ticket No.0468 Time 9:50 Unit Wt lbs/cu ft Air Content (%) GENERAL REMARKS: Inspector Premium Travel Name Time Hours Time Ryan Doucette No REVIEWED BY:Bryan M. Crabtree FRACTURE TYPES Type 1 Type 2 Type 3 Type 4 Type5 Type 6 Reasonably well-formed Well-formed cone on Columner vertical Diagonal fracture Side fractures at top Similar to Type 5 cones on both ends,one end, vertical cracks cracking through with no cracking or bottom (occur but end of less than 1 in.running through caps,both ends, no through ends; tap commonly with cylinder is [25 mm] of cracking no well-defined cone well-formed cones with hammer to unbonded caps)pointed throught caps on other end distinguish from Type 1 Page 2 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 08-21-2019Compressive Strength Report - Concrete Report No.33 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.Aggregate Industries Our reports are available in PDF form via email. Please email us at reports@utsofmass.com for more information. cc:Fulcrum Associates Bob Levesque Fulcrum Associates Brad Scott Fulcrum Associates Darrin Standish DMS Design Sid Silveira DMS Design Dan Skolski City of Salem Steve Cummings Veitas & Veitas Linas Dabrila DSF Group Paul Bowie DSF Group Benjamin Greene Fulcrum Group Patricia Dwyer UTS Matt Chace Page 3 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 08-21-2019Compressive Strength Report - Concrete Report No.33 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.Aggregate Industries FIELD SUMMARY REPORT Total Pour:Pier Footings Method of Placement:Pump Chute Discharge Bucket OtherX Other: Vibrator OtherMethod of Concrete Consolidation:X Other: Cylinder Fabrication Location:Truck Discharge Chute End of Pump HoseX Cylinder Storage:Curing Box Thermal Blanket Hay/Straw Trailer FieldX Other Placement Protection:Thermal Blankets Heat NoneX Other Slump Specification (in.)4-6 Number of slumps out of specification reported to If rejected Approved by Remarks: