Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
75 WILLSON STREET - BUILDING INSPECTION
75 WILLSON STREET Pmi /c. O. COPY .CpNDfT� CERTIFICATE OF OCCUPANCY CITY OF SALEM Issued. 3 �P'ermit p: 4 SALEM, MASSACHUSETTS 01970 City of Salem Building dept. fi 4- `rAd.0/MINE'WN� DUNE 13 97 309-1997 DATE_ 19__.� PERMIT NO. APPLICANT GROOM CONSTRUCTION CO. INC. ADDRESS `214 ESSEX ST. — (NO.I !STREET) itONTR'S LICENSE) CITY SWAMPSCOT f STATE MA ZIPCODE 01907 TEL NO. 6177-59c-3135 NEW 91-JIL.DING GOLF COURSE CLUBHOUSE NUMBEROF 1 PERMIT TO, � (_) STORY DWELLING UNITS (TYPE OF IMPROVEMENT) NO. (PROPOSED USE) 012175 WILLSON STREET — � _ ZONING RC FT (LOCATION)_.a. (NO.I !STREET) -� BETWEEN _ AND—,--,, _ (CROSS STREET) $CROSS STREET) MAP `"3 0Q11�)I LOT -•70. 63 ACRES SUBDIVISION LOT BLOCK..... ......— SIZET ` BUILDING IS TO BE_ FT.WIDE BY FT,LONG BY _FT.IN HEIGHT AND SMALL CONFORM IN CONSTRUCTION TO TYPE USE GROUP_.... BASEMENT WAILS OR FOUNDATION ..—.._.. (TYPE) REMARKSPE=RMIT FOR GOLF COURSE= (:.LUBi-iOUSE:: PER PLANS SUBMITTED. L. E. 'T. . AREAOR 448. '98'/1 PERMIT 'T-9. 00 VOLUME ESTIMATED COST_ _T— FEE ICUBICISQUARE FEET) OWNER._CITY OF SAI_E:M BUILDING DEPT nDDREss 9:6 ,WRE!il-1TNt-iTC.11V ST�-^—. - -J.-- - ©Y__—..----_l_-C•��..__ Tommattmrttlt4 f Ansssr4usets W i CITY OF SALEM eW` In accordance with the Massachusetts State Building Code, Section 108. 15, this CERTIFICATE OF INSPECTION is issued to RI._LY" S ON 1'HE GREEN i Tfrtifg that 1 have inspected the premises known cis PAL.l_Y' S ON -(FIE UREc.EI\I located at 0iZi75 W11._LSO1\4 6*1REET in the city of Solent County of Essex Co in mo it toe Ith of Massachusetts. The means of egress are sitfficieitr for the faIIotoiitg number of persons : BY STORY Story Ca $aXI15�tGs567757b5G7KC%7G$7G% i' XIu75'X5C74 AStYL7KA p75c�XsG55S65$Twt7Fy °6 Capacity Story Ca�uis �,xcws � Capacity BY PLACE OF ASSEMBLY OR STRUCTURE Place of Assembly Place of Assembly or Structure Capacity Location or Structure Capacity Location Fl 1 F3 Qi1E4" 1999 LD5/01 199.7 V:.rvi7�a. /La7n;�iZ (t y Certificate Number Date Certificate Issued Date Certificate Expires Building Offi 4ilf The building official shall be notified within (10) days of any changes in the above information. LU _ L Co:^ ON'WZALT3 OF vASSA UCSFI= CIT7 OF SALE-L! 9T T T' C T r APPLICATION FOR C3S_:IG1ic 0. VSYE_.ION Date Fee Required S ( ) No Fee Required in accordance with the provisions of the Nsssacausectz State Building Code. 108, 15. i bereov apply for a Cerrificace of laspecc-on for the below-aaned pr= located a[ the following address: Street 6 Number 2!P - MA,5�/ Name of Premises rj.w / �jp rnR&-e'/� Purpose for which Premises is used re-,&d Licenses) or Perait(s) required for the prcme-s- by ocher Gover=ental Agencies License or Permit Amcncv TA /74% ( -. Cert1_`icace cc be issued to: Address: /l� "�lJ` �So(.J rS1 Owner of Record of Building: Address: '' 11 Name of Present Bolder of Cert i_"_care: NE,� 1" �YN ame of A enc. _f anv. . . Q_ LU Cp `` c C.D gure or ?crs a o vaon �ert':_eate TI=Q isy;i�sued o Nisi er authori_cd agent _ 1 -� � (� L� =� Dace INSTRUCTIONS• Day cin, phone 1'7yy-6� 7(, I. Hake check payable cc: The City of Salem Z. Return this application with your check cc: Insneccor of Budldinzs. Clty of Sa Buildinz Denarrmenc. One Saler Green. Saha. :!1. )1970. PLEASE NOTE: 1. APP licacloa is=--:form with required fee must be submitted for each building or s : of part thereof to be cerrifi,d_ ?. Application 3 fee muscbe received before the ccrr=f'-care w-i11 be issued. / J. The building official shall be norified within tea ( 10) days of any change i. c f above inzor-.st±cn. r ( I qq =I3AITON DATE: 52-0,tz® L. Yl2vyf _ f lr2 IZ i I i I PERIODIC INSPECTION REPORT This form is to be completed each time a Periodic Inspection is made. At the time a new Certificate of Inspection is issued, a notation indicating that the fee has been paid will be made to Application Form prior to the new Certificate of Inspection being issued. Any changes since the last inspection are to be added to the file card of the premises. Street & Number Name of Premises /yam/ �5 /o//J /� c�/t""-F ✓ Certificate to be issued to: Address 7 5 Owner of Record of Building Address Purpose for which premises are used 1&S/g-,- Changes since last Inspection (required on file card also) L . 3. 4. 5. Date Order Issued: Order Issued To: Address Date Violations Corrected: REMARKS: I have this day inspected the above premises, and the same conforms to the pertinent requirements of the Massachusetts State Building Code and the rules and regulations pursuant thereto. Date Building Official Certificate $ / Date Issued: Date Expires: O O Recommended Next �I � (�nntmnnzrtti#i of x b CITY/TOWN OF In accordance with the Massachusetts State 0uilding Code, .Section 108. 15, this CERTIFICATE/ OF INSPECTION in issued to . . . . . . . . . / is . � � / . . . '. . . . . . . . . . . IQlv rtif, that I have inspected the. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . known as. . �1j�f. • ��f • f�^) located at. . . . . ?� . ! ��SoaJ . . . . .. . . . . . . . . in . . .of. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . County of. . . . . . . . . . . . . . . . . Commonwealth of Massachusetts. The means of egress are sufficient for the following number of persons: BY STORY Story Capacity Story Capacity Story Capacity Story Capacity BY PLACE OF ASSEMBLY OR STRUCTURE Place of Assembly Place of Assembly or Structure Capacity Location . , or Structure Capacity Location A -3 IK Certificate Number fate Certificate Issued Cate Certificate ExpiresBuilding ffi.cial The building official shall be notified within (10) days of any changes in the above information. - GenFlex 1722 Indian Wood Circle Suite A Maumee,OH 43537 Roofing Systems Tel: 800-443-4272 Dear Building Owner: Thank You for choosing a GenFlex Roofing System. Your choice of a GenFlex roof means that we now have more than 200,000,000 square feet of polymer roofing under warranty. The warranty number and job name on your project is as follows: Warranty Number: 97-29963-92-N �- Job name: OLDE_SALEM-GREENHOUSE CLUBHOUSE Job Location : 75 W_ILLSON STREET_.) SALEM,-MA-01970--/ Enclosed you will find a SPRI roof maintenance manual for your referral along with a roof maintenance sticker. Please remove the backing from this sticker and place it near the roothatch. This is a quick and easy reference for individuals who will have access to your roof. GENCORP CAUTION THE ROOFING SYSTEM ON THIS BUILDING IS UNDER WARRANTY BY GENFLEX ROOFING SYSTEMS. IT IS IMPORTANT THAT YOU, THE OWNER, ARE AWARE OF YOUR RESPONSIBILITIES TO KEEP THE WARRANTY IN FORCE. A. Regular preventive maintenance should be conducted, including: (1) All drain areas and drains are cleaned on a regular basis. This will allow for proper water run-off and avoid overloading the roof with ponding water. (2) All counterflashing, metal work, equipment curb and supports, pitch pockets, caulking, and any other rooftop accessories functioning in conjuction with the membrane roofing system be kept properly maintained at all times. (3) No materials are stored on the roof and the building owner removes broken bottles, metal, etc., and reports all dam- ages and vandalism to GenFlex Roofing Systems. (4) Regular cleaning of areas where contaminants harmful to the roofing system may accumulate, i.e., grease, Freon. B. Should you have a leak: (1) Contact GenFlex Roofing Systems Warranty Claims Administrator at (800) 443=4272. (2) Determine the cause of the leak. It may be the result of a clogged drain, loose counterflashing, etc. Failure to determine the cause may result in a service charge fee. (3) Under the terms of the warranty, notify GenFlex Roofing Systems in writing of all leaks within thirty (30) days. (4) If necessary, make temporary repairs with GenFlex edge caulk or a butyl J base caulking. Never use roof cement or petroleum base products. (5) Permanent repairs to the roofing system must be made by an ap- proved GenFlex contractor with GenFlex products. C. The building owner should contact GenFlex Roofing Systems in writing: (1) For approval, before making alterations on or through the roof system or when changing the interior use of the building. (2) Whenever there is a leak. 'jGenFlex Roofing Systems 1722 Indian Wood Circle Maumee, Ohio 43537 800-443-4272 � G� _ �v��. �� �" �-"-'L �� ��-.. I i � ray i k 5re y'd^ Y:i ASH � 1 f fes..! t g s e` Manual of Roof Inspection, Maintenance, and Emergency Repair for Existing Single-Ply Roofing Systems IIIIIII�I • . I . I SPRI/NRCA Manual of Roof Inspection, Maintenance, and Emergency Repair for Existing Single-Ply Roofing Systems �I I Published by: Single Ply Roofing Institute (SPRI) Wellesley Hills, Massachusetts National Roofing Contractors Association (NRCA) Rosemont, Illinois April 1992 Copyright © 1992 By Single Ply Roofing Institute and National Roofing Contractors Association. All rights reserved. No part of this work may be reproduced without the written permission of the publishers (with the exception of the Historical Record and Owner Maintenance Inspection forms). Single Ply Roofing Institute (SPRI) and its members disclaim responsibility for the ap plicability in all circumstances of the information contained in this manual. SPRI specifically disclaims responsibility for any loss or damage to property. In the event manufacturers' recommendations for maintenance differ from information in this manual, the manufacturers' directions should be followed. TABLE OF CONTENTS Page 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1.1 General . . . . . . . . . . . . . . . :. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1.3 Manufacturer's Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . _ . . . . . . . . . . . . .1 1.4 Service Agreements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 1.5 Membrime Identification. . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 1.6 Rooftop Access. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 1.7 Roof System Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... . . . . . . . . . . . . . . . . .3 2.0 ROOFING SYSTEM HISTORICAL RECORD . . . . . . . . . . . . . . . . . . . . . . . . . .3 3.0 CAUSES OF ROOF PROBLEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 3.1 Natural Causes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 3.2 Man-Made Causes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 3.3 Other Causes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 I 4.0 ROOF INSPECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 4.1 Regular Periodic Inspections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 4.2 Special Inspections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . _ . .6 4.3 Inspection Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 5.0 OWNER PERFORMED MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 6.0 EMERGENCY REPAIR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 6.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 6.2 Leak Repair Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 6.3 Wind Damage Repair Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . _ . .14 6.4 Permanent Repair Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 7.0 INSTALLATION OF NEW PENETRATIONS AND EQUIPMENT . . . . . . . . . .17 6.0 CONCLUSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 9.0 APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Historical Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Roof Plan Grid. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Owner Maintenance Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 i 1.1 General 1.2 Definitions p Y I Maintenance has always been a con- Inspection is defined as a critical ex- cern to owners of buildings, but amination of the components of the previously it has been associated only roof system. Maintenance is defined as with equipment and the processes the the work of keeping a building, fl buildings house. It is only recently, machinery, roof, etc., in a state of •' Y' *i however, that owners have recognized good repair. Some examples of roof the need for ongoing inspection, maintenance include cleaning drainsY, maintenance, and repair of the roof- and removing debris. ing systems that protect these + + ¢ a I - buildings and their contents. Even Repair is defined as returning to good though mann-actmers' warranties may condition after damage, decay, etc.; be provided for the roofing systems, mend; fix. Some examples of roof _ q they generally do not relieve the repairs include patching a puncture in owner of the responsibility for proper the membrane or flashing, or replac- maintenance. ing components damaged by high winds. d t Periodic roof inspection and mainten. ance programs are now being routine- 1.3 Manufacturer's Warranty a ly implemented with increasing s' frequency. Designers, contractors and One of the most important things a manufacturers can be a valuable re- building owner with a manufacturer's source to building owners regarding warranty can do is to read and d '! the necessary aspects of roof understand the warranty for the roof- $ t a maintenance. ing system installed on his building. 4 v This manual offers some basic recom- A manufacturer's warranty is a legal ! " mendations for building owners and contract between the owner and the their represer_tatives that will assist in manufacturer. It can be voided like keeping roofs watertight and performing. any other contract, whether knowingly With the support of professional roofing' , `t tP 'Iph., 40"an ar'm`a' +t as g6+ka ram sz a a� a +* mg, x, a # contractors and roof• � , rr ttr v5 �ariev ing materialmanufac- " turers, owners should � develop ongoing t maintenance pro- 6 w grams to optimize r v roof service lite. 21 at ti t' ? « a t � ^ve i P I n n kvy + 8 • y , or inadvertently. Common occurrences The best time to establish a service can arise after the warranty has been agreement is when the roofing system issued which may result in a voided is installed. A building owner should warranty. These occurrences may in- contact his professional roofing con- clude, but are not limited to: tractor for recommendations concern- ing the type of service or maintenance • Neglect of the roofing system by not contract that would be appropriate for performing inspections, repairs and his roof(s). l routine maintenance in a timely manner; 1.5 Membrane Identification • Failure by the owner to notify the Although many single-ply roofing I� membrane manufacturer of leaks in membranes look alike, they may re- the roofing system in a timely man- quire different materials for repair. ner (most warranties will explicitly The type of single-ply roofing material state a time limit); used should Abe noted on the mem- brane warranty, its related paperwork, -' • Failure by the owner to notify the or in the historical record (see Section membrane manufacturer of work re- 2.0) for the roofing system. If, how- quired to repair damage or to add ever, these sources do not identify the rooftop equipment; membrane, contact your professional roofing contractor or other roofing Is • Failure to have permanent repairs professional to aid in the identifica- or maintenance performed in tion of the roofing material. It is im- accordance with the manufacturer's portant to identify the roofing material instructions, such as: in question so the correct materials and repair method may be selected. —use of material not manufactured I" by the warranting manufacturer, 1.6 Rooftop Access or the use of an incompatible material for a repair; The building owner, or the owner's representative at the building site, is —work performed by a contractor responsible for controlling access to not approved or authorized by the roof. Generally, roofing systems the membrane manufacturer to are not designed for traffic other than perform such work. that required for maintenance as per- formed by trained personnel. In order • A change in the use of the building; to limit access to approved personnel, the roof hatches or access doors • A change of ownership of the should be kept secured. A sign should building; many warranties are non- be posted at the point of access to the i transferable. roof stating that only authorized per- sonnel are allowed onto the roof. In 1.4 Service Agreements addition, a log should be kept of all individual visits to the roof and the A service agreement is generally in the corresponding reasons for such visits. form of a maintenance or service con- tract between the building owner and Prior to accessing the roof in cold the professional roofing contractor for weather, check with the membrane a specific time period, with a possible manufacturer to see if there are cold option for renewal. Typically covered weather precautions or limitations. are periodic inspections and the per- formance of specific routine mainte- Note: When the roof membrane is nance. A report of the general roof identified as unreinforced PVC, roof- ' condition is usually submitted to the top traffic should be avoided when building owner after each inspection, the ambient temperature is below with recommendations for immediate approximately 50°F. The individual and future action, manufacturer of a product should be consulted for a specific recommenda- tion regarding minimal temperature. 2 Y od,.v e ` Access to the roof: " should be'limited t' _ A authorized, trained x personnel. r' 1 i w , i P4 .�,.,. W � d e F 7��fk•,•gar 1.7 Roof System Access roofing membrane for inspection or repair difficult. Should one of these Some single-ply roofing systems have roofing systems be encountered, and if Itlay aggregate or concrete paver surfacing. removal and reinstallation of the rc. E:. +!iIr"" * r Additionally, protected membrane material covering the membrane is re- � roof systems have an insulation layer quired, it should be performed by a above the waterproofing membrane. professional roofing contractor. 4 t' These systems make accessibility to the 1 - .O Oy 0 - tl a.tt d is z tt it a The building owner should maintain a to document all subsequent inspec- historical record of the roofing system. tions, maintenance and repairs per- ! 3 This historical record will provide the formed on the roof system since its owner with data concerning the installation. This information should y original roofing installation such as minimize the cost of repair and t , membrane type, the contractor that in- maintenance work. A sample stalled the roof system and the mem- Historical Record form is included in t brane manufacturer. The owner the Appendix. k�f" r. should also use the historical record r, 11, m gpg�,,,. i i €� =Keeping complete r"historical records �l should help to x t Q minimize the cost of S te '�„ a s f t r l ' l.- maintenance and r a s repair.' is gra 3 All roofing systems have a finite • Manufacturing defects, such as errors service life. This service life can be in formulation or in fabrication optimized by performing periodic in- spections, routine maintenance, and • Use of products or components that r repairs. Similarly, this service life can have exceeded their shelf lives be reduced by a number of causes. This section identifies some of the • Improper addition of roof penetra- causes of problems that affect roof tions after the original installation service life. Because of the potential of the roofing system. A common o development f problems, routine source of improper additions is * Periodic inspections ons a re recommended "tenant-finish" of the interior building for early detection. space, which typically includes penetrations for HVAC (heating,ven- s Any of the following conditions may tilation, and air conditioning) units, result in decreased roof service life. antennae, and plumbing vent stacks. 3.1 Natural Causes • Lack of proper maintenance of items such as pitch pockets at roof • Long-term exposure to the elements, penetrations, building joint sealants such as sun, water and freeze-thaw (caulking), counterflashings, drains, cycles copings, embedded edge metal, F masonry walls, and rooftop units. • Exposure to air pollutants and industrial atmospheres • Incorrect, or lack of, response to problems can result in compound- * Extreme weather, such as hail, ing the original problem. Roof lightning, high winds and drenching problems should be corrected pro- rains (which raise the water level mptly to avoid time-consuming and above the flashing heights) costly corrections at a later date. • Structural movement such as • Changes in interior use of the building settlement, seismic building, such as the change of an movement, and thermal expansion office space to a laundry. The and contraction original roofing system may not have been designed for the subse- • Animal intrusion, including insects quent high indoor relative humidity and birds generated by a laundry and may consequently experience condensa- r • Biological growth including tion problems. vegetation, fungus, and algae • • Contamination of the membrane by 3.2 Man-Made Causes substances which are not compatible with the roofing materials. These • Design deficiencies, including contaminants may be spilled or ex- improper or inadequate design of hausted onto the roof, may be air- elements of the roofing system such borne, or may be mistakenly used as structure, details, drainage, and as repair materials on the roof. loading • Abuse, vandalism, rooftop traffic, • Workmanship deficiencies, other trades or any individual who including improper preparation of either does not belong on the roof the substrate, improper storage of or who has little regard for the per- materials prior to installation, formance requirements of the roof- inclement weather during applica- ing system. As stated previously (see tion, and failure to follow manufac- Section 1.6), only trained, author- turer's specifications and details ized personnel with business on the 4 roof should be allowed onto the —drainage system roof. —water piping and gas, electric, or y other utility lines 3.3 Other Causes —louvers a a a' —windows ¢; e t a m r' • Condensation, or moisture that may —skylights/smoke hatches be erroneously identified as a roof —walls and sealant joints a a leak, may adversely affect the roof- a " a $ a +yt ' F t ' a � � t ing system's performance. • HVAC (heating, ventilation, and air conditioning) equipment, in addi- • a Water infiltration may be tion to being a source of water en- x erroneously attributed to defects in try, can also cause unacceptable the roofing system and may ad- differential building air pressures , t e verset affect the roofing system. which may affect the wind erfor- $ '+ j = ' , -yt :a + °ry Y g Y Y P t, a a: t Water may infiltrate through any of mance of the roofing system. " the following building elements: ' a a a € a 11 r d - One of the key elements of any roof understands the design and basic maintenance program is regular roof components of the roofing system. inspection. Another key element is Many professional roofing contractors a. immediate attention to all identified provide this service upon request for 4v s t problems. a fee. If the roofing system is currently It is recommended that the spring in- e a covered by a manufacturer's warranty, spection be performed by a roofing P'a " a s i, t both the roofing membrane manufac- professional; the owner or the owner's $ a ' a 4, t a a Periodic ins ction b '* +9 n- to• `4 f k " yq}a e' #'z f a knowledgeab y a inspector is a'key _ element of a roof f t. `maintenance* t,s s " #• ' 'program. $ $ n F � w�,'d-. �' �x a 4 +&C�" kT. w +t,,,.•�'$ �, u a yy .. .z $ n a � $ • �...d g._ .t 'fi' ', psi(,, .. n .' -i + �, a,*y a $. �o toter and the roofing contractor representative should accompany the should be contacted if problems are roofing professional during this in- s. p ', a detected in the roofing system during spection if he/she is going to perform an inspection. In the absence of a the inspection in the fall. The spring a a s + $ $$ warranty, either a professional roof- inspection should be done early ing contractor or the membrane enough to allow for any maintenanceda manufacturer should be contacted to or repair required to take place in t $' i• obtain sound repair and maintenance the prime construction season. s ' s f " ` ' advice. a , ' > $#4 Late in the fall an inspection by a 4.1 Regular Periodic Inspections roofing professional, or the owner or _ the owner's representative, should be Every spring and fall, the roof should scheduled to assure the roof is ready be inspected by a person who for the upcoming winter season. a� ' ' r$a<• 5 x. • " t $ tx, $ s'sq 4.2 Special Inspections 4.3 Inspection Procedure - r k t When extraordinary situations occur Each inspection should follow a which may affect the roof, inspections prescribed routine which enables the should be made as soon as possible by inspector to examine each visible com- a roofing professional. Special inspec- ponent of the roofing system. A sam- tions are recommended when: ple Owner Maintenance Inspection r form is included in the Appendix for Art �K • construction affects the roof or your use. adjacent roof areas; The starting point of an inspection • new equipment is installed on the should be the interior of the building. ' roof, The interior should be checked for x� s'.z n leaks; check interior walls and ceilings • unusual weather conditions occur, for signs of water and staining. A jL such as large hail, high winds, floor planlroof plan should be unusually heavy snow loading, or developed from this interior inspec- other extraordinary weather tion to indicate where there may be y' phenomenon; problems at the roof level. After in- iv, 4 Extraordinary situa• s, tion , such as unusual weather con- ditio.7s,i signal the need for special, unscheduled inspections. 1t 3 i u^A !y' tk „ t{ a� u'r4 'r t , r - , C y • any maintenance, repair, or reroof- specting the interior, check the ex- o- t ing on the roof or an adjacent area terior walls and overhangs for cracks, } is undertaken; (It is best to perform movement and signs of moisture. a special inspection prior to and a after the completion of this type of The roof should then be inspected by work.) checking the roof components in the °_ s' g following order. 0,, s i ' • there is a fire or other known tt damage to an adjacent roof area. 6 I _ � 4 .� . `I#Cap clashing(such as ` the coping shown ik here) should be in- spected for displace- _='w ¢ ment,'deformation ! V i ; and corrosion. a • r± 1 �p q • r moi_ �` • ` ... '�r.. . . .*tea.} �-ems.' 4 it fa 0 r E Cap Flashings: Cap flashings are • corrosion of metal components; att metal or other rigid cove-s at v ° membrane terminations. These in- • missing or loose joint covers; elude counterflashings, expansion 4 ' join, covers, and copings. Cap • sealants displaying signs of crack- '' t sem' • r: flashings are a protection fcr the ing or weathering or aging. a membrane termination and often provide a waterproof cap or cover D Edge Meal: Edse metal is used at S Ekk'• I� at membrane terminations. The in- the edge of a roofing system to ter. spector should look for the fcllowing: minate the roof and provide water- Ip proof flashing at this junction. k� • lcose or missing fasten?rs; Leakage at metal edge terminations can cause serious damage to the + s x ; • loose or displaced sections of metal; structural components, as well as + f- the membrane and insulation, if • deformed metal which could col imprope_ly maintained. The in- a A . . lect or direct water and f-unnel it t st ttrough an end joint; Metal edge termina- tions should be a 'checked for splits, corrosion, and 'displacement r .64 OW SlIk IWA % ` r , Spector should look for the and that there is no extensive following: bridging or loose membrane; „ . • loose or missing fasteners; Note: Some base flashings are im r •w_ tentionally loose, except where tr • loose or missing stripped-in they are adhered or secured at flashing; the top and bottom. k • splits in the stripping at metal • thc- bottom of the base flashing flashing joints; at its attachment to the field r. r m=mbrane to detect open seams e • corroded metal; or other problems; E f • missing or displaced metal sec- • vertical laps for unsealed seams; tions or joint covers; • sealants displaying signs of crack- 9 open end joints; in„ weathering or aging; •w• • sealants displaying signs of crack • base flashing material for signs ing or weathering or aging. of deterioration or building t �, •_ w movement. O Base Flashings: Base flashings are roof membrane terminations at p Penetrations: Penetrations are walls and curbs. Because of the pipes, drains, and other items that ' f many conditions which require penetrate the roof membrane. flashing, a variety of problems may They must be flashed properly to occur at these vulnerable locat'ons. assure a watertight roof. The in- s ^'t tk•t. When inspecting base flashings, Spector should examine the check the following: following: Oar , • the top termination to ensure it • the drain clamping ring and • tt " is secure and sealed, if the top drain strainer are properly seal of the membrane base secured to ensure a watertight flashing is exposed; seal at the membrane-to-drain � a, interface; • th2 adhesion of the base flashing ;� . to the substrate to determine • thorough adhesion of sealant in- }, Vis'-„ that it is relatively continuous Bice pitch pockets and mem- Ease /lashings and _—�—•^— pitch'pockets at penetrations are important elements --_ for periodic 1.rspection �t �* , w�f 8 t I ' brace adhesion around the out- unbonded membrane when the . sides of pitch pockets; roof is an adhered roofing system; 3 ' 71 t • pitch pockets, for adequate fill • there are no worn spots, _ material to prevent water from deteriorated areas, or holes in r W n collecting in the pitch pockets; the membrane; � _it�3.; • pipe boot flanges for tight seal • there are no changes in the in- a with the membrane; sulation or substrate firmness as the roof is walked upon; a • the top of pipe boots for a seal v =y tr i around the pipe(s). • ballast (aggregate or pavers), if stx x i. present, is continuously p Field Membrane: Deficiencies in distributed; ` the main body of the roof can be a potential problem. It is important Note: Occasional small bare 10 er ` to note that the removal of ballast spots, approximately the size of (aggregate or concrete pavers) to a person's foot, are generally inspect the membrane is not part acceptable. of a routine inspection. Therefore, 3` - where possible, the inspector • surface coatings, if present, are should check that: continuous and have not b r` = t deteriorated; 't • exposed seams (laps) are sealed; I, v t, 41 When inspecting the f ,5eid of the rcof, the integrity of seams ` should be examined. f ry 1P 10 t. . r , r � °,t, c t w jt there are not excessive wrinkles, the roof has adequate drainage; „ blisters, or ridges; (If areas of inadequate drainage 4 exist, other than "bird baths," jl h JV ;4o Note: Some roof membranes are they should be noted on the loose laid and wrinkles are an roof plan.) '• expected consequence of expan- OW' ' sion and contraction. there are no areas around rooftop t " there are no fasteners pro equipment that have been de- { graded by equipment leaks or truding against (tenting) the spills, or that have been punc- i membrane; Cured by dropped tools or equip- ment parts. • � "� °7s there are no excessive areas of at " ° a a ' 4 A; i ` y y�r•. 9 r.. � i#x r r In addition to check- ing the condition of. x;# 1 penetrations, the •membrane should be t ' inspected closely for damage, such as punctures ar tears, i caused by workers ' . maintaining rooftop equipment. Eon W— _ - s The life of a roofing system may be them until a professional roofing optimized with regular, periodic contractor is available to repair the ' inspections and a few simple membrane after their removal. maintenance procedures. • Remove obstructions (such as leaves =, The Owner Maintenance Inspection or dirt) from roof drains and/or form found in the Appendix notes scuppers, and ensure that they are { numerous items which are followed by flowing freely. If there is a possibili- } ' r. _ 4 an "action needed" recommendation. ty that a roof drain or scupper is Items such as weathered sealants, loose still obstructed after clearing the base flashings, and protruding obstruction, it should be water tested a +� r•?. `,. ., . fasteners should be referred to the ap- with a hose for draining ability. propriate professional as noted on the 4 _)t �"�' 1. _ inspection form. Note: If a roof drain or scupper is I' �4 t" s :•" blocked by ice, do not physically ' i �,�• g ', .}•x. There are several other items which break or chip away the ice. (Use of 'f t building maintenance personnel or a heat tapes may avoid drain freezing professional roofing contractor should and the use of deicing salts.) 0s perform after each inspection: ) '$ ,- • Ballast should be continuously ' • Gather debris such as paper, bottles, distributed (except for occasional e ;' <•} broken glass, tree limbs, vegetation, small bare spots, as previously 3 : r5 or any other foreign matter and discussed). Ballast should be redistri- dispose of them properly. buted with a push broom as neces- sary to cover the membrane and Note: Remove any tree limbs or prevent uneven loading. If ballast other items that could fall onto the redistribution is a recurring prob- roof and cause damage. If vegeta- lem, consult the roofing contractor tion has roots extending into the or membrane manufacturer for recom- roof membrane, do not remove mendations to correct this problem. 10 i Periodic removal of' i"'';,debris from drainsromotes flow of water from the P roof r 41 u s w s° '-t,m ,Y martx IJ' Lir; $+, R r PC eii f,Ii 4, , s. pi k, :f? 1!,i . I • If traffic patterns are developing maintenance item and will generally across the roof (e.g., caused by require reapplication(s) during the P p,MR y x„ workmen maintaining mechanical life of the roofing system. Many fac- is equipment, washing windaws, etc.), tors affect the frequency of consult the membrane manufacturer recoating, such as local environ- _ to determine how to best protect ment, ponding water, slope, and not in 4 the roofing membrane from the only the type but the quality of the traffic: coating. Recoating work should be performed by a professional roofing • Examine the roofing membrane contractor. where any of the above items were found for evidence of ph-;sical Note: Recoating is the responsibility damage. If membrane reFairs are of the building owner and is an in- f, needed, they should be performed tegral part of the maintenance of a L .s*ias, by a professional roofing contractor, roofing system which employs the r If the roofing system is covered by use of a surface coating. a membrane warranty, notify the t l+ manufacturer of the roofing mems In addition to these items, any other brane as soon as possible to obtain conditions noted during the inspec- •rx 1i, instructions and recommendations tion should be acted upon by the ap- to facilitate a permanent -epair. propriate trained personnel. • Observe the integrity of sarface ry coatings. A surface coating is a ._ g fo i a Special walkways . should be installed :+ when traffic patterns Aim of maintenance per-, *'sonnel are created ryc; r � Kx * x4,.,1 •..� i. t�,.ryv'� �`it., }`. y4 - •S'. i..r: ,.r.. el it = I , • n f11 t � 6.1 General If literature cannot be located or if procedures are not detailed for Emergency repairs may be required emergency repairs, the following after severe weather because leakage guidelines are suggested: into a building can occur at any time (nights, holidays, weekends, etc.). 1) Protect the interior: Control the Caution: It is generally not advisable spread of water in the interior by col to attempt roof repairs until after the lecting the water in containers or by severe weather has ceased, due to the using plastic sheeting to protect the danger of high winds and the possi• building contents. bility of a lightning strike. Caution should be exercised when inspecting 2) Remove excess water from the roof: a roof after there has been severe Check roof drains and scuppers to be weather, or when there is suspect certain that they are open and funs damage to the roofing assembly, tional. A frequent cause of roof because storm damage may have left leakage and roof collapse is excessive the roof in a hazardous condition. If ponding on the roof surface due to the roof condition is questionable, clogged drains and/or scuppers. , . . hi. have a professional roofing contractor a perform the inspection and necessary Caution should be exercised when repairs. In the event a professional clearing debris from drains. Signifi- roofing contractor is not available, cant suction forces can be created by and to minimize damage to the in- draining water, which can suck tools, terior building finishes and contents, hands, or arms placed within these emergency repairs may be performed. vortices quickly into the drain. Emergency repair procedures should 3) Locate the source of a leak: In at- be as simple as possible so they may tempting to determine the source of a be performed safe) b building leak, locate the point on the roof sur- maintenance personnel or similar face above the area of leakage in the nonroofing professionals. These building interior. From this point, first repairs should be considered tem- check the condition of rooftop porary. Permanent repairs should be mechanical equipment, then check all made by a professional roofing con- flashings at terminations and penetra- tractor as soon as weather permits. tions. Second, if the system is ballasted remove ballast from the immediate If the roofing membrane is under a leak area, then check the membrane manufacturer's warranty, the roofing surface for cuts or punctures. Finally, membrane manufacturer should be check the seams (laps) in the roofing contacted as soon as possible. membrane. Following are emergency repair In many cases, it can be extremely dif- guidelines that may be performed by ficult to locate the source of a leak on building maintenance personnel, a roof membrane that has been install- 3 similar nonroofing professionals, or by ed over insulation placed on a strut professional roofing contractors. rural concrete deck, or over an existing membrane or vapor retarder. 6.2 Leak Repair Procedures If the source of a leak into the n There are too many different types of building cannot be readily located, the roofing membranes to tailor emergen- owner or building maintenance Per- cy repair procedures for each. Consult sonnel may have no recourse except the roofing membrane manufacturer's to control the spread of water until a t literature for products and procedures professional roofing contractor can be " r recommended for emergency repairs. contacted and arrives at the site. 12 4) Perform emergency repairs: Once Sealant and Roof Taffies the source of a leak is located, the ,.; s` b ` materials and procedures which will To make emergency repairs, start by cause the least amount of damage to cleaning the membrane surface with the roofing membrane should be alcohol or a household cleaning solu- chosen. The following table categorizes tion, such as window cleaner. Then _ 1� w rteion the listed emergency repairs by roof. wipe the surface with a clean cloth ing system type. and "splice cleaner" or white gas fl EMERGENCY (TEMPORARY) REPAIR PROCEDURES i ,ROOFING,. Plastic Sealant andx t. . . Duct Wood Bentonite GSYSTEM ` Cement Roof Tapes ,,.Tape Block +Clay:., . W h - yHIs . Ballasted See Yes Yes Yes Yes Loose Laid Note IT Single ply Below V .. ks, •' " Fit iMechanically See Yes Yes May Yes Attached Note Be Singe ply4rg Below,_ ',, Possible 8 a $; F „ _ •a't 9 r r" R 3 yy tf't +µ Of Adhered See Yes Yes No Yes Single-ply Note t ' Below u t$,t g Modified,„ YesMay May No Yes r i..Bitumen Be Be " Possible Possible t •9.# g u r�N�7 x s ���fi: .�.,,,,..:,' + 'r�3? �t,� a xj,�r 'h'a a a x. � 3 1t :- 6d + .y�',. Note:Plastic cement may deteriorate some types of single-ply membranes and in some cases, may also deteriorate the insulation in the roofing system,and may cause interior staining. d f fie, Plastic (Roofing) Cement (use rubber gloves and proper skin tYV protection). p An emergency patch can be made r N using plastic cement and fabric or After the membrane has been cleaned, „ s'i roofing felt. apply a butyl or polyurethane sealant v (caulking), or roof tape to the damaged i" Permanent repairs should be made as membrane. (Note: The membrane sur- quickly urquickly as possible. This type of repair face must be clean for the repair l ° may require a larger section of single- material to adhere to the membrane.) ve, ply membrane (and perhaps the in- When using roof tape, pressure should sulation) to be removed prior to the be applied over the entire surface of KID permanent repair in order to ensure the tape to ensure adhesion. that any of the existing membrane r if contaminated with plastic cement is Sealants are available at most hard- • no longer present. ware and discount stores. A variety of roof tape products are also available. a3 Plastic cement is a trowel-grade pro- These products typically have a release ({ . duct. It is available in "rain patch" or paper on the backside and are a few y' 'Ist "wet patch" grades, which are some- inches wide. Roof tape products are what easier to apply to wet or dam also available through membrane PPY P g surfaces. Avoid the use of a liquid or pourable asphalt repair product. pt# a kId I, '13 I ,Ke. fl manufacturers, roofing materials Place two of these wood blocks, one distributors, and roofing contractors. on top of the other, through the hole. Then staple or nail the edge of the ' k # Duct Tape membrane to the wood blocking to ` µ ' -#,"� prevent the cut hole from enlarging Make a patch for the roofing mem- due to stress placed on the membrane. ' brane using common duct tape. (Note: This procedure will raise the hole A The sheet must be clean and dry in several inches above the roof surface, order for the tape to stick. Cleaning out of any ponding or surface water, + f guidelines are described in the and should immediately stop the leak. "Sealant and Roof Tapes" section.) Place a small metal cap, cone, or bucket over the hole through which A Wood Block the wood blocks were inserted and A ^ secure the cover to stop additional • ,_ r., ,. If there is a puncture in the mem- water entry. This procedure avoids t, brane or a small seam problem where any contamination of the membrane 5+ the membrane is not totally adhered, and should keep the building dry un- P_nctures or small -- til a permanent repair can be made. seem problems can _ * When a permanent repair is made, ba prevented from the wood blocks should be removed. developing into a g sutnificant leak by the ; . f Bentonite Clay uae of the temporary "mood blockin technique. g" � '" Spread bentonite clay granules ap- ,, proximately V thick in the area of the i leak. The bentonite clay will expand, y4 (� ' ` 3k forming a water impermeable seal r which bonds to the membrane surface. ' 7 a hole is enlarged a-d a small wood r y ; k - ' The bentonite product is a natural oiock is inserted to ZLv clay which should not have a elevate the opening ; above the water line. + y deleterious effect on the membrane - f surface. However, the seal is tem- porary and should be replaced with a permanent patch as soon as possible. - �`- ----" (Note: Bentonite clay should be kept Atter the block is in , - away from all roof drains to avoid place, a bucket is drain blockage.) Use of bentonite clay positioned r i generally necessitates extensive clean- . 3., + : i; ,� .. up of the membrane surface prior to permanent repair. 44 t -Ate- _ 6.3 Wind Damage Repair Procedures ,rid weighted to keep If roof damage is observed during a it in place. storm, it is generally not advisable to attempt repairs or damage control un- 4 til after the storm because of the s ,t y •, danger of high winds and the i possibility of a lightning strike. r' t 7 �� a}t '•+n- In some instances, however, repairs during a storm may prevent or 1 minimize further wind damage. For make a small circular incision at the example, if a loose metal edge flashing puncture or seam. The incision should is observed, securing it during a storm may prevent subsequent lifting, peel be large enough to allow a 2" x 4" x b wood block to the hole, ing, and blow-off of the membrane. If ' under the membrane. work is performed during a storm it !, should be done by a professional roof- r u t ing contractor at his discretion. Work to aid in locating them for later per- ' should not be performed during high manent repair.Except for areas less than winds or electrical storms. If a profes- 50 square feet (e.g., five feet by ten sional roofing contractor is not feet), inspection and permanent re. available, work should not be under placement of ballast should be per- ;v . taken unless wind speeds are formed by a professional roofing moderately low and electrical storm contractor. 5 r a activity has ceased. k 'i L' �•b r,, N Temporary Ballast. Bare areas greater Following the storm, loose debris on than 50 square feet should be tem- the roof that could be blown off in a porarily ballasted using sandbags, tires, r subsequent storm should be removed. concrete blocks, or concrete pavers. Because some roofs are in a hazardous When applying temporary ballast, use condition after wind damage, debris caution to avoid overloading the strut. After high winds, the roof should be in- spected for debris, " ballast scour, oven xfi seams and punctures P n or other signs of # damage. 131 is a k +� Y" removal should be performed by a ture. In some cases when the temporary professional roofing contractor if one ballast materials previously mentioned is available within a reasonable time were not available, children's rigid period. plastic swimming pools have been used as temporary ballast. Caution: Different types of attachment methods When using these types of swimming require special considerations, as pools, care must be taken to avoid r discussed in the following guidelines: overloading the roof deck and strut- v [ural support, since rain water could 1 } !j n 4. ova Ballasted Systems: After high winds, fill the pool which would add weigh[ , the roof should be inspected to deter- to the system. Use swimming pools up v i mine if ballast (aggregate or pavers) to approximately 6' in diameter filled tz t' "' t , t has been scoured (scattered), leaving with approximately 3" of water. Cut !` areas of bare, unprotected membrane. holes 2" (minimum) in diameter in If so, the exposed membrane should the side of the pool no more than 4" be inspected for open seams, punt- above the bottom of the pool to avoid ) tures, and tears from flying debris overloading the structure. (from rooftop mechanical equipment or from adjacent buildings). Mem- If lightweight concrete pavers were brane damage should be temporarilyused for the ballast and were displac- , a r x a repaired, as discussed in Section 6.2, ed, use concrete blocks, heavy con- before redistributing the ballast. trete pavers, or sandbags to achieve a V Ir k� minimum load of about 40 pounds sit, p Temporary repairs made to the mem- per linear foot around the perimeter b +i'1f.t w brane should be marked on a roof plan of the bare area. (The width of the I` '15 ' t - Ilk 4 ptyY; Stemporary ballast around the perimeter If any of the above conditions are to achieve the 40 pound load will observed, a professional roofing con- depend on the weight of the ballast tractor should make the permanent �tt q being used.) Place the temporary repairs. t P , ballast on top of the remaining , _ I t rt "fi•'t lightweight pavers to provide tem- If a mechanically attached membrane Yt M , t porary protection against further wind is observed billowing, consult the t g S damage until permanent repairs are membrane manufacturer. While some made. In conjunction with setting tem- billowing may be normal, an excessive y= a ytG 1 + porary ballast of 40 pounds per linear amount would indicate that design ,01 foot,, 1*" foot around the perimeter of a bare enhancements may be advisable. area, also apply temporary ballast to { a secure the membrane when the bare If all or a portion of the membrane is qn fit. area exceeds 50 square feet. peeled back, the building is vulnerable Z. a 11 VVI dyt e to water infiltration. In some in- Iiinsulation boards tiireposition the In some instances, nsuaton oars sances, t s possible to tS = tl 5e '� P wt Ii, below;r, a below the membrane are displaced. membrane to provide temporary pro- be tec sitioning uld be Displaced F t4 D�sP�aorao finals redistribution pofition- formed by aoprofessionaloroofingper ballast. If membrane cutting is re- contractor if one is available within a quired to reposition the boards, it reasonable time period. After reposi- B should be performed by a professional tioning, the membrane should be roofing contractor. fastened at the perimeter, the damage V " n "v ' repaired,and temporary ballast installed. 04 S e t ISI P When bare areas exceed 50 square II feet feet or when ballast is blown off the If membrane is too damaged to be tYy 1 ^ "i J1 1 roof, consult the membrane manufac- repositioned for temporary protection, qty' , ;ri toter because, in either of these cases, replacement material will be needed. " design enhancements may be advisable. If a professional roofing contractor cannot provide temporary or perma- . Mechanically Attached and Adhered nent roofing service within a Systems: After high winds, the ex- reasonable time period, it may be fiyz _ posed membrane should be inspected necessary to utilize large tarps or. p at""h gi for damage from flying debris. If sheets of polyethylene secured at the d fasteners mp upandpuncturredk he membrane, or previously d scropped perimeter and ibedorarily ballasted as if debris has punctured or torn the membrane, temporarily repair it as 6.4 Permanent Repair Requirements, , t ; • s described in Section 6.2. The emergency repair procedures ti�" 4'y€t�. Mechanically attached membranes described in the previous sections are in nature and ust Y "r � •*i ."�F if anyinspected en bars or fassteninngtplatese be"reply ed with ypermanent and com- �1t , iSrt S.'t' were uplifted, or if the membrane has plete repairs by a professional roofing C� I q, " t separated from them. Likewise, fully contractor in a timely manner. If the adhered membranes should be in- roofing system is covered by a mem- t4 spected to see if they separated from brane warranty, notify the manufac- It Y�3 Y ; ryt`1 Ssfi the substrate. If the membrane is unat- toter of the roofing membrane as tached from the substrate or fastening soon as possible to obtain instructions system, and the area exceeds 50 and recommendations to facilitate a square feet, temporary ballasting permanent repair. iy7" t'" r should be performed as described previously under "Ballasted Systems." 1 I , c t ;r,r q' It -Iris- .31 y M 7 §t•4° fi t"�t `���.? 0 P NOW"{ a" One of the most common causes of stallation will allow the manufacturer leakage is the improper installation of to recommend how to incorporate the '.`r new roof penetrations or equipment. new penetration or equipment and - Y a ! Orscussioh-with the roofing manufacturer prior to instalation of new penetrations or ;'equipment should en- sure that proper pro- cedures are used by [i -.t the professional roof- t _ r ing� contractor. e . `r ; " r , y V m a � f: To avoid roofing problems associated how to protect the membrane warran- f with new penetrations or equipment, ty, if one exists. f notify the manufacturer of the roofing membrane prior to the installation of The addition of penetrations or equip rooftop penetrations or equipment, in. ment to the roofing system should be cluding items that may be set upon undertaken by a professional roofing the membrane. This would include contractor qualified to perform such such items as TV antennae, sign or work.The name,address,and telephone equipment supports, skylights, plumb- number of a roofing contractor t fit ing soil stacks, and HVAC equipment. qualified to perform the work can be f p obtained from the roofing membrane The name and telephone number of manufacturer, if the original roofing the roofing membrane manufacturer contractor is not available. Improper r should be written on your historical installation of penetrations or equip- rE record form. Notification prior Co in ment may void the roof warranty. r-P a t i A -A 0 $ e F J ala yx^ a �" 4t, tyc s , #' By making a commitment to periodic ing roof access, the roofs service life . . MAWz '.' Historical Record All information and records pertinent to this roofing system should be a part of this record, e.g., meeting minutes, copies of repair records, etc. General Information Building: Tenant: Location: Phone: Contact: Owner: Architect/Consultant: Roofing Contractor: Membrane Manufacturer: Warranty Terms: Dates Installed: Warranty Coverage Period: Membrane: From: To: Membrane Thickness: Roof Access: Ladder Hatch Insulation: Building Height: Design Windspeed: Roof Area: sq. ft. Specification Information Construction If recover, describe existing Type: ❑ New ❑ Tear-Off ❑ Recover system: Roof Deck Concrete: thickness Type: ❑ Poured ❑ Precast ❑ Plank ❑ T-Beams ❑ Lightweight ❑ Other Concrete: Wood: thickness Type: ❑ Tongue & Groove ❑ Plywood Steel: gauge Gypsum: thickness Type: ❑ Slab ❑ Plank Other: Roof Slope: inch/foot Areas of Inadequate Drainage: ❑ Yes ❑ No Drainage System: Briefly describe the roof drainage system, including drains, plumbing, scuppers, gutters, downspouts and sumps, if any. Single-Ply Membrane Thermoset: ❑ CSPE (Hypalon) ❑ ECH ❑ EPDM ❑ Neoprene Thermoplastic: ❑ CPE ❑ CVA ❑ EIP ❑ NBP ❑ PIB ❑ PVC Modified Bitumen: ❑ APP ❑ SBS Installation Method: Surfacing: ❑ Ballasted ❑ None ❑ Stone: Type ❑ Mechanically Fastened ❑ PMR ❑ Pavers: Type ❑ Fully Adhered ❑ Granules ❑ Coating: Type ❑ Partially Adhered ❑ Other 19 Roof Plan Grid No. For use in conjunction with the Owner Maintenance Inspection Form. Building: Inspection Date: Location: Inspector: Scale: 1 t -I- - -VF � ® V r 20 Owner Maintenance Inspection No. Provide the roof plan using the roof plan grid on page 20 to indicate the location of observed conditions keyed to this inspection report. Use the item codes to show location. Building: Inspection Date: Location: Inspector: Contact: Membrane: Surfacing: Attachment: Has the occupancy or use of the building changed since the last inspection? ❑ No ❑ Yes If yes, how? Have any changes, additions or new penetrations been made to the roof since the last inspection? ❑ No ❑ Yes If yes, how? Has there been leakage? ❑ No ❑ Yes If yes, under what condition? ❑ Light Rain ❑ Heavy Rain ❑ Wind Driven Rain ❑ Leaks Continuously Were emergency repairs performed? ❑ No ❑ Yes Describe: Inspection Checklist: Perform an initial general building inspection; condition may indicate roof problem. Note location for in- vestigation on roof: ITEM CONDITION ACTION ACTION CODE PRESENT NEEDED TAKEN INTERIOR rfr = Roofing Contractor Roof deck mfr = Membrane Manufacturer Al. Rusting Contact rfr/mfr A2. Spatting Contact rfr/mfr A3. Cracking Contact rfr/mfr A4. Buckling Contact rfr/mfr A5. Sagging Contact rfr/mfr A6. Open Joints Contact rfr/mfr Walls B1. Movement Contact rfr/mfr B2. Settling Contact rfr/mfr B3. Cracks Contact rfr/mfr B4. Spalling Contact rfr/mfr B5. Paint Peeling B6. Water Stains EXTERIOR Walls Cl. Mortar Joints Contact rfr/mfr C2. Cracks Contact rfr/mfr C3. Stains C4. Efflorescence C5. Sealant Joints C6. Windows 21 ITEM CONDITION ACTION ACTION CODE PRESENT NEEDED TAKEN C7. Fascia Displaced Contact rfr/mfr C8. Gutters Anchored Contact rfr/mfr C9. Downspouts Contact rfr/mfr ROOF General D1. Ponded Water Contact rfr/mfr D2. Debris D3. Physical Damage Contact rfr/mfr CAP FLASHINGS Counterflashing E1. Loose/Missing Fasteners Contact rfr/mfr E2. Loose/Displaced Metal Contact rfr/mfr E3. Deformed Metal Contact rfr/mfr E4. Corrosion Contact rfr/mfr E5. Loose/Missing Joint Covers Contact rfr/mfr E6. Cracked Sealant Contact rfr/mfr E7. Punctures Contact rfr/mfr E8. Other Contact rfr/mfr Coping F1. Loose/Missing Fasteners Contact rfr/mfr F2. Loose/Displaced Metal Contact rfr/mfr F3. Deformed Metal Contact rfr/mfr F4. Corrosion Contact rfr/mfr F5. Loose/Missing Joint Covers Contact rfr/mfr F6. Cracked Sealant Contact rfr/mfr F7. Punctures Contact rfr/mfr F8. Other Contact rfr/mfr Expansion Joints G1. Loose/Missing Fasteners Contact rfr/mfr G2. Loose/Displaced Metal Contact rfr/mfr G3. Deformed Metal Contact rfr/mfr G4. Loose/Missing Joint Covers Contact rfr/mfr G5. Spliced Joints Contact rfr/mfr G6. Strip Flashing Contact rfr/mfr G7. Punctures Contact rfr/mfr G8. Splitting Contact rfr/mfr G9. Mechanical Damage Contact rfr/mfr G10. Hinder Drainage Contact rfr/mfr G11. Other Contact rfr/mfr EDGE METAL H1. Loose/Missing Fasteners Contact rfr/mfr H2. Loose/Missing Stripped-in Flashing Contact rfr/mfr H3. Splits in Stripped-in Flashing Joints Contact rfr/mfr H4. Corrosion Contact rfr/mfr H5. Loose/Missing Metal Sections Contact rfr/mfr H6. Loose/Missing Joint Covers Contact rfr/mfr 22 ITEM CONDITION ACTION ACTION CODE PRESENT NEEDED TAKEN HT Open End Joints Contact rfr/mfr H8. Cracked Sealant Contact rfr/mfr H9. Other Contact rfr/mfr BASE FLASHING J1. Exposed Top Seal Contact rfr/mfr J2. Adhesion Contact rfr/mfr J3. Seams/Attachment to Field Contact rfr/mfr J4. Vertical Laps Contact rfr/mfr J5. Cracked Sealant Contact rfr/mfr J6. Deterioration Contact rfr/mfr J7. Punctures Contact rfr/mfr J8. Sagging/Wrinkling Contact rfr/mfr J9. Excessive Bridging Contact rfr/mfr J10. Other Contact rfr/mfr PENETRATIONS General K1. Pitch Pocket Sealant Contact rfr/mfr K2. Loose Flashing Contact rfr/mfr K3. Draw Bands Contact rfr/mfr K4. Other Contact rfr/mfr Drains L1. Strainers/Clamping Ring L2. Clear of Debris L3. Flashing Contact rfr/mfr L4. Ponding Contact rfr/mfr Rooftop Equipment M1. Attachment to Curbs Contact rfr/mfr M2. Access Panels M3. Housing I M4. Liquid Discharge Contact rfr/mfr M5. Condensation M6. Roof Protected Contact rfr/mfr Conduit or Pipe N1. Sagging N2. Supports Moving Contact rfr/mfr N3. Joints N4. Corrosion MEMBRANE General 01. Discoloration Contact rfr/mfr 02. Coating/Surfacing Contact rfr/mfr 03. Cracking Contact rfr/mfr 04. Wrinkles Contact rfr/mfr 05. Punctures Contact rfr/mfr 06. Walkways, Displaced 07. Walkways, Deteriorated Contact rfr/mfr 08. Walkways, Needed Contact rfr/mfr 23 ITEM CONDITION ACTION ACTION CODE PRESENT NEEDED TAKEN Seams P1. Open Joints Contact rfr/mfr P2. Fishmouths Contact rfr/mfr P3. Ridges Contact rfr/mfr P4. Blisters Contact rfr/mfr Adhered Membrane Q1. Unadhered Areas Contact rfr/mfr Q2. Blisters Contact rfr/mfr Q3. Loose Insulation Contact rfr/mfr 04. Fasteners Backing Out Contact rfr/mfr Mechanically Fastened R1. Loose Membrane Contact rfr/mfr R2. Loose Fasteners Contact rfr/mfr R3. Fasteners Backing Out Contact rfr/mfr R4. Non-penetrating Systems Contact rfr/mfr Ballasted S1. Stone Coverage Contact rfr/mfr S2. Wind Scour Contact rfr/mfr S3. Pavers Contact rfr/mfr S4. Walkways Contact rfr/mfr MISCELLANEOUS T1. Antennas T2. Guy Wires T3. Exhaust Vents T4. Ice or Icicles T5. Oil Deposits Contact rfr/mfr T6. Surface Contamination Contact rfr/mfr T7. Soft Areas Contact rfr/mfr T8. Vandalism Contact rfr/mfr T9. Vegetation Growth 24 ��''"� t � ., �� � " , A �� � � Citp of batem, jf1a!6swbug;ettg (Electrical department Abut JR. Tuttle Citp electrician 44 Idapette btreet *atem, AZA 01970 'CeI 508-745-6300 fax 508-745-4638 DATE: OCTOBER 23, 1997 TO: E. LAWRENCE MCINTIRE SUPT. PARK & RECREATION DEPARTMENT FROM: PAUL M. TUTTLE, CITY ELECTRICIAN SUBJECT: OLDE SALEM GREENS NEW GOLF COURSE CLUBHOUSE 75 WILLS09 STREET PLEASE BE ADVISED, VIA OUR CONVERSATION THIS MORNING, THE CHANGE ORDER FOR THE ELECTRIC SERVICE DISCONNECT WAS IN VIOLATION OF THE MASSACHUSETTS ELECTRIC CODE . DUE TO THE MISTAKE IN THE DRAWINGS ON THE SPECIFICA- TIONS, IT IS MY UNDERSTANDING, THE CITY IS NOT RESPONSI- BLE FOR THE ERROR IN THE SPECIFICATIONS, THIS IS AN ARCHITECTS PROBLEM. 7 PAUL M.TUTTLE CITY ELECTRICIAN CC: BUILDING INSPECTOR FAXED: 740-9299 PMT/M