Loading...
UTS Job 23418 Report 24 Compressive Strength Report - Concrete 07-29-2019 (002)-Page 1 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 07-29-2019Compressive Strength Report - Concrete Report No.24 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.J.G. MacLellan ALL FIELD TESTS DONE ACCORDING TO ASTM:C-172 C-31 C-143 C-1064 C-39 C-1231ALL COMPRESSIVE STRENGTH TESTS DONE ACCORDING TO ASTM: CLASS CONCRETE:3000# 3/4"No. Of Sets:1 17CUBIC YARDS: SET 1 LOCATION:Footing; Column lines G at 1, Building #2 Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type X872 4.00 x 8.00 12.57 Good 07/29/19 08/05/19 7 36,500 2,900 1 X873 4.00 x 8.00 12.57 Good 07/29/19 08/12/19 14 48,000 3,820 2 X874 4.00 x 8.00 12.57 Good 07/29/19 08/26/19 28 55,000 4,380 1 X875 4.00 x 8.00 12.57 Good 07/29/19 08/26/19 28 58,000 4,610 2 X876 4.00 x 8.00 12.57 Good 07/29/19 08/26/19 28 57,500 4,570 1 Slump (in.)5 1/2 Air Temp. (F.)89 Conc Temp (F)88 Truck No.244 Ticket No.9324 Time 2:20 Unit Wt lbs/cu ft Air Content (%) GENERAL REMARKS:Cylinders received on 08/05/19. Inspector Premium Travel Name Time Hours Time M. Chace No REVIEWED BY:Bryan M. Crabtree FRACTURE TYPES Type 1 Type 2 Type 3 Type 4 Type5 Type 6 Reasonably well-formed Well-formed cone on Columner vertical Diagonal fracture Side fractures at top Similar to Type 5 cones on both ends,one end, vertical cracks cracking through with no cracking or bottom (occur but end of less than 1 in.running through caps,both ends, no through ends; tap commonly with cylinder is [25 mm] of cracking no well-defined cone well-formed cones with hammer to unbonded caps)pointed throught caps on other end distinguish from Type 1 Our reports are available in PDF form via email. Please email us at reports@utsofmass.com for more information. Page 2 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 07-29-2019Compressive Strength Report - Concrete Report No.24 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.J.G. MacLellan cc:Fulcrum Associates Bob Levesque Fulcrum Associates Brad Scott Fulcrum Associates Darrin Standish DMS Design Sid Silveira DMS Design Dan Skolski City of Salem Steve Cummings Veitas & Veitas Linas Dabrila DSF Group Paul Bowie DSF Group Benjamin Greene Fulcrum Group Patricia Dwyer UTS Matt Chace Page 3 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 07-29-2019Compressive Strength Report - Concrete Report No.24 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.J.G. MacLellan FIELD SUMMARY REPORT Total Pour:Footing; Column lines H.8 at 1 - D at 3, Building #2 Method of Placement:Pump Chute Discharge Bucket Other Other: Vibrator OtherMethod of Concrete Consolidation:X Other: Cylinder Fabrication Location:Truck Discharge Chute End of Pump HoseX Cylinder Storage:Curing Box Thermal Blanket Hay/Straw Trailer FieldX Other Placement Protection:Thermal Blankets Heat NoneX Other Slump Specification (in.)4-6 Number of slumps out of specification reported to If rejected Approved by Remarks: UTS of Massachusetts, Inc. Page 4 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 07-29-2019 Report No.24 Job Number 23418 Project Halstead Salem Station, 72 Flint Stree Salem, MAAttachment