Loading...
UTS Job 23418 Report 27 Compressive Strength Report - Concrete 07-09-2019 Page 1 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 07-09-2019Compressive Strength Report - Concrete Report No.27 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.Aggregate Industries ALL FIELD TESTS DONE ACCORDING TO ASTM:C-172 C-31 C-143 C-1064 C-39 C-1231ALL COMPRESSIVE STRENGTH TESTS DONE ACCORDING TO ASTM: CLASS CONCRETE:3000# 3/4" *No. Of Sets:1 10CUBIC YARDS: SET 1 LOCATION:Wall: Column Line A at 18 Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type M725 4.00 x 8.00 12.57 Good 07/09/19 07/16/19 7 27,000 2,150 1 M726 4.00 x 8.00 12.57 Good 07/09/19 07/23/19 14 33,000 2,630 2 M727 4.00 x 8.00 12.57 Good 07/09/19 08/06/19 28 45,000 3,580 1 M728 4.00 x 8.00 12.57 Good 07/09/19 08/06/19 28 48,000 3,820 2 M729 4.00 x 8.00 12.57 Good 07/09/19 08/06/19 28 46,500 3,700 1 Slump (in.)5 Air Temp. (F.)76 Conc Temp (F)84 Truck No.164 Ticket No.8448 Time 1:45 Unit Wt lbs/cu ft Air Content (%) GENERAL REMARKS:*MRWR. Cylinders Received 7-10-19 Inspector Premium Travel Name Time Hours Time Jordan Depina No Min Day 1 Hr(s) REVIEWED BY:Bryan M. Crabtree FRACTURE TYPES Type 1 Type 2 Type 3 Type 4 Type5 Type 6 Reasonably well-formed Well-formed cone on Columner vertical Diagonal fracture Side fractures at top Similar to Type 5 cones on both ends,one end, vertical cracks cracking through with no cracking or bottom (occur but end of less than 1 in.running through caps,both ends, no through ends; tap commonly with cylinder is [25 mm] of cracking no well-defined cone well-formed cones with hammer to unbonded caps)pointed throught caps on other end distinguish from Type 1 Our reports are available in PDF form via email. Please email us at reports@utsofmass.com for more information. Page 2 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 07-09-2019Compressive Strength Report - Concrete Report No.27 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.Aggregate Industries cc:Fulcrum Associates Bob Levesque Fulcrum Associates Brad Scott Fulcrum Associates Darrin Standish DMS Design Sid Silveira DMS Design Dan Skolski City of Salem Steve Cummings Veitas & Veitas Linas Dabrila DSF Group Paul Bowie DSF Group Benjamin Greene Fulcrum Group Riley Bourque UTS Matt Chace Page 3 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 07-09-2019Compressive Strength Report - Concrete Report No.27 Distribution Copy Job Number 23418 Project Halstead Salem Station, 72 Flint Street Salem, MA Contractor Fulcrum Associates Concrete Co.Aggregate Industries FIELD SUMMARY REPORT Total Pour:Walls; Building #2: Column Line A between 18-12 Method of Placement:Pump Chute Discharge Bucket OtherX Other: Vibrator OtherMethod of Concrete Consolidation:X Other: Cylinder Fabrication Location:Truck Discharge Chute End of Pump HoseX Cylinder Storage:Curing Box Thermal Blanket Hay/Straw Trailer FieldX Other Placement Protection:Thermal Blankets Heat None OtherX Slump Specification (in.)4-6 Number of slumps out of specification reported to If rejected Approved by Remarks: UTS of Massachusetts, Inc. Page 4 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 07-09-2019 Report No.27 Job Number 23418 Project Halstead Salem Station, 72 Flint Stree Salem, MAAttachment