A&1 Realty Trust ■ PO Box 2027 ■ Salam MA 01970-6227 . 781-593"
July 7, 2004
Conservation Commission
City Of Salem
120 Washington St
Salem, MA 01970
re: 4 Technology Way
Dear Commission Members,
We are the holders of the property at 56 Swampscott Road, Salem MA(Map 7
lot 64), that abuts along a line, the applicants property at 4 Technology Way,
currently under permit review. We have some issues concerning the property located
at 4 Technology Way and we have decided to bring these issues forward now.
During Farfard's clearing & grading of the industrial park, they had brought
the buildable portion of their property, to the same elevation as the rear of our
property (see Photo 1).
We understand, for your reasons, you required that water run off from
4 Technology Way be routed through the storm drain system at Technology Way.
We concur as we do not want their water run off entering our property either.
We assume that is why Farfard had then raised the topography of their lot.
They did so by delivering a large amount of soil and spreading it out over their
property in order to grade their topography to a considerably higher elevation where
their property abuts ours.
You may not be aware that, in doing so, Farfard had spread some of this soil
over the stone boundary that had remained after their first grading (see Photo 2).
This stone boundary, now covered, had continued along the same line as a fieldstone
boundary that delimits their property from ours. We state that, we reserve the right
that if and when alterations are to be made to our topography, they would be in a
manner acceptable to us and at a time of our choosing. We are displeased that
Farfard had altered this, though small, portion our topography, regardless of their
intentions in this act.
Second, since Farfard had raised their topography above ours, no retaining
wall had been placed against the edge of this higher elevation of soil (see Photo 2
again)which is technically required. Without a wall in place, their soil will spread
further onto our property from the compressing and squeezing out of the soil caused
by the motion of construction equipment during future construction, and from the
continuous changing weight distribution of the future parking lot along that edge, and
also from weathering against that open edge. All of the above will result in an erosion
and a lessening of the current slope of the grade along this edge of their property,
which may also be of concern to you.
AWBUTTERN7-727
Ultimately we seek correction of these conditions as follows:
1) The removal of the soil that currently extends onto our property.
2) The construction of a wall, on their property, to retain their soil.
We would assume that customarily, the seller being the cause of, would be
responsible for, regardless of any potential buyer, and in this situation, the most
skilled and able to make these corrections; would offer to make these corrections
prior to the property's sale, so as not to hinder a buyer's efforts. Though now that
the seller and buyer are under agreement, they could re-negotiate their terms to
include these corrections, we hope, amicably, and swiftly, if they have not already
done so.
So, for the present:
We ask that the buyer & seller determine which party will be
responsible to make these corrections.
We ask for the party assuming these corrections to provide us with a
written agreement stating that the corrections will be made within two
years, or prior to further development, whichever occurs first; in lieu
of immediate correction.
We_ack.fnr the City Of Salem to attach a proviso onto the building
permit requiring that these corrections are to be made prior to further
development, and that they provide us with the written agreement to
correct, stated above.
We pray that the City Of Salem will consider our requests and concur with us.
Sincerely,
George J. Corso,
Managing Trustee
cc: City Of Salem Planning Board, 120 Washington St, Salem NIA 01970
A&AABUTTER6V-727 -
l
$ _ Y
- r
Photo of i iLot 64(left), and the property at
Technology
,ra
F . ,S
r A, ?
' �br
40 *,
r
Photo 2. View of the boundary between Lot 64(left), and the property at
4 Technology Way(right), after raising the topography of 4 Technology Way.
ABMBUTTERS17-727
I MW
CITY OF SALEM, MASSACHUSETTS
BOARD OF APPS
AL
KIMBERLEY DRISCOLL
120 WASHINGTON STREET♦ SALEM,MASSACHUSEM 01970 _4 A 2b
- 9595 TELE:978-745- 4 FAX:978-740-9846
MAYOR FILE #
CITY G6f�, 8I+LfM.MASS.
February 4, 2015
Decision
City of Salem Board of Appeals
'petipetition Of JUDYLYNN MONACO seeking a Special Permit per Sec. 3.1 Principal Uses, to operate a medical
tion
for
r a portion of the property located at 4 TECHNOLOGY WAY (Map 7, Lot 79) (BPD Zoning
District).
A public hearing on the above Petition was opened on January 21, 2015 pursuant to M.G.L Ch. 40A,
The hearing was closed on that date with the following Salem Board of Appeals mem
Curran (Chair),Mr. Duffy,Mr. Watkins,Mr. Copelas,Mr. Tsitsinos (alternate). bets present: Ms.
The Petitioner seeks a Special permit
Ordinance. from the Provisions of Sec. 3.1 Principal Uses of the Salem Zoning
Statements of fact:
1. In the petition date-stamped December 29, 2014, the Petitioner requested a Special permit to allow
the use of a medical clinic for a portion of the property located at 4 Technology Way.
2• Ms.Joanne O' Connell, architect with NEMD Architects, Inc. of Providence,Rhode Island presented
the petition on behalf s. the applicant Davita Healthcare Partners. The petitioner,Judylynn Monaco,
Project manager and Ms.Julie Higgins Van Sickle, facility administrator for Davita Healthcare Services
regional office located in Salem,MA were also present.
3. The petitioner,Davita Healthcare Partners is requesting a Special Permit per.Sec. 3.1 Principal Uses to
operate a medical clinic in a portion of property located at 4 Technology Way.
4. The current use of 4 Technology Way is research, technology and general office space.
5. The proposed medical clinic is a dialysis center that would provide services
patients per day and staff thirty-two (32) employees per day, to approximately 66-88
6. The current facility located at 10 Colonial Road in Salem does not meet current service demand.
Therefore the company is seeking the possibility of relocation to 4 Technology Way.
7. The proposed hours of operation of the dialysis clinic are from 5am to 8pm.
8. Approximately 22 patients would access the site independently by car or by ambulance services in
three shifts per day starting at Gam, l lam,and 4pm.
9. The facility will also have 1-2 deliveries made per week by a tractor trailer.
10. There are a total of ninety-five (95) parking spaces for the entire shared facility. The handicapped
center,while the remaining parking Options for
spaces that are located closest to the proposed clinic entrance would be designated for the dialysis
patients and employees will be first come first serve.
11. The requested relief, if granted, would allow the Petitioner to
the property at 4 Technology Way. operate a medical clinic for a portion of
City of Salem Board ofA
February4,2015 Appeals
Project: 4 Technology Way
Page 2 of 2
12. A petition in opposition was submitted as part of the records for this petition.
13. At the public hearin
Opposition to g no (0) members of the public spoke in favor o£and five 5
the petition. The opposition was generally on the grounds that the
conflict with the industrial ark ( ) members spoke in
The Salem Board of Appeals, P proposed use was in
after thorough review of ahs, after careful consideration of the evidence presented at the
the petition, ding the application narrative and Public hearing, and
Presentation and public testimony, makes the following �
Provisions of the City of Salem ZoningOr pis' and the Petitioner s
Ordinance
gs that the Proposed project meets the
Findings for Special Permit
The Board expressed its
Therefore co understanding that Technology spay was created as
commercial and retail based uses present conflicts with the existing an industrial park.
uses in this building and industrial park area. In particular, the
found to be in co ting and future industrial
conflict with other uses in the buil Proposed P Park
a hen client
Enda that this use is inconsistent with and industrial traffic was
park specifically: the existing uses and in Park area. The Board therefore
CO�het with the current industrial
2.1• The socia], economic and community needs would be served by the proposal.
this
Traffic flow and safety,including Parking and loading as proposed and discussed are inadequate this location.
3• The utilities q ate for
and other public services are adequate.
4• There are no impacts on the natural environment including drainage as no additional cons
Proposed.
5. A medical clinic, as ro construction is
6. The potential fiscal Proposed,is inconsistent and incompatible with current uses at
impact,including impact on the City's tax base and employmenttins location.
positive.
On the basis of the above statements of facts and findings, would be
favor and five (5) opposed (Rebecca C the Salem Board of Appeals
Tsitsinos), to grant a S ecial Pe on'Peter A. Co elas Watkivoted none (0)in
P rnrit, to allow the operation of a medical c��Tom Watkins and Jy�y
THE PETITION IS DENIED. hntc located at 4 Technology Way,
19
cc
jeecca—Curran' Chair ��ard of Appeals
A COPY OF THIS DECISION
HAS BEEN FILED WITH THE PLANNING BOARD AND THE CITY CLERK
-*peal from this deanon,if any,sha!!be made panwwt to Section 17 0
dy's o,f f:(ixg of thu decinon in the offrre of the Ci C .Jthe Massarbarettr
ap
Special Femrit granted berein shall not take xH by a PHrsH°°t to the MarrachHretts Generalllamr Chapter¢0 q, and shall be filed untbin 20
Registry of Deeds. py of The deciriox bearing the rertifirate a the
wCi Cb ter 40A Section >7, the Variance or
./ ry Clerk has been filed xath the Essex Smsb
4s 810
t tP ,y' accmGr - x
�
Nehmacta
� Y �
16 Crystal Street, Melrose, MA 02176 781-662-3498 ((ax)781-662-8389
fiddRepolt
To: Tom St.Pierre
CC: Peter Varone
From: Dan DiLullo
Date: May 18,2012
Re: US Biological
We have been at the site repeatedly over the last 3 months and,to be blunt,work was proceeding very
slowly until the past month beginning in early April. In that 4 to 6 week period a lot of the cosmetic work
has been substantially completed. That work includes:
• Interior painting
• Vinyl tile flooring
• Suspended ceiling installation
• Installation of carpet tiles in most areas
• Ceramic tile floors in toilets and janitor closets
• Installation of toilet fixtures and accessories
• Installation of electrical devices and fixtures with completed wiring
• Completion of fire alarm and life safety equipment
• Installation of welded stair rails at egress stairs
Work in process for this report:
• Continuation of glass rail installation at front stair and atrium(bases and clips are in place)
• Enclosure and completion of egress stairs
• Installation of porcelain tile in main lobby
• Installation of vinyl base at vinyl tiled and carpeted floors
• Installation of interior glass walls,windows and doors
Also substantially complete:
• HVAC systems (currently operating in all"occupied"areas of the building.
• Elevator(inspection scheduled the week of May 21-25)
• Emergency generator installation(equipment in place—wiring in process)
Major materials on site
• Owner equipment
• Doors and frames
The exterior of the building is complete with the exception of 2 broken windows and some door hardware
replacement.
May 18, 2012
In the original design of the building US Biological was proposing to occupy 60%of the first floor and
50%of the second floor. Those percentages have remained thru the construction but the layouts have
changed,mostly by field changes co-ordinated by the Owner,his interior designer,our firm and the MEP
engineers. There is currently some discussion about modifying the back area of the building by installing
a floor over the existing atrium and developing tenant spaces. We are encouraging the Owner to allow us
to further study of that back area while we assess the changes required(architectural,structural and
mechanical)to incorporate any such modifications. We feel strongly that the US Bio portions of the
building should be completed and occupied prior to any work being done in the back. The only work in
process is the enclosure of the back egress stair as required by Code.
Although we are not responsible for it we offer the following regarding site work. The site is still in some
state of disarray but,as we understand it,is getting closer to completion. The Owner has engaged the
services of Alliance Engineering from Saugus to survey the site,the utilities as installed,the drainage and
grading. Alliance has the list of concerns form the Conservation Commission,the Planning Department
and DPW. He is addressing those areas of interest to them including:
• Existing site grading and pavements will be modified as required to ensure slope to drainage
structures
• The site drainage and structures will be surveyed and modified(if required)to ensure proper
drainage to the detention basin
• The slope on the left side of the site will be designed as a sloped stone revetment to safely hold the
bank(the wall has been designed and submitted to Dave Knowlton and written permission from the
abutter is in hand)
• The street repair and catch basin at the comer of Technology Way and Swampscott Rd has been
designed and submitted to Dave Knowlton,he has made some continents which will be incorporated.
• The final parking layout has been determined(at a meeting with me,Danielle McKnight and Tom
Devine) and will be incorporated in"as built'site plan.
• Grades and final configuration of sidewalks and HC ramps as shown on the approved site plans.
The interior work being performed appears to be in substantial compliance with the contract documents
and in accordance with the Code requirements. If the work proceeds at the current pace we anticipate we
will be prepared to issue Final Affidavits by the end of the this month.
Dan DiLullo
2
Certificate No: 922-11 Building Permit No.: 922-11
Commonwealth of Massachusetts
City of Salem
Building Electrical Mechanical Permits
This is to Certify that the BUSINESS located at
-----------------------------------------------------
Dwelling Type
TECHNOLOGY WAY in the CITY OF SALEM
---------------------------------------------------------------------- -------------------------- ------------- --- - -------- ---- -
Address Town/City Name
IS HEREBY GRANTED A PERMANENT CERTIFICATE OF
OCCUPANCY
OCCUPANCY PERMIT FOR(2 NEW STORY OFFICE BUILDING)
This permit is granted in conformity with the Statutes and ordinances relating thereto, and
expires unless sooner suspended or revoked.
Expiration Date
--i-------------------------------------- ----
Issued On:Thu Apr 25,2013
--- -- ---
GeoTMS®2013 Des Lauriers Municipal Solutions,Inc
f i
TECHNOLOGY WAY 922-11
PIS# 15s93 COMMONWEALTH OF MASSACHUSETTS
Map. ' T 07
Block a v uil. ;I ;e. CITY OF SALEM
Lot ; 0087
Category '�4; New Commerwal Buil`
P rmt#. ,�` 922 11 : ri.0 �. BUILDING PERMIT
Ptolect#ua,'_n;� JS-2012-000236
Est. Cost: $1,647,300.00
Fee Charged:!, $0.00
Balance Due $ oo aa� PERMISSION IS HEREBY GRANTED TO:
Const Class "1 a Contractor: License: Expires:
Use Group: 0-1 ,I'll Dan DiLullo Construction Control-6033
LotSlze(sq ft.) i'i ih . ,�I¢ Til
Zoinng Owner: U S Biological
Units Gamed �F ;n ,iApplieant: Da DiLullo
Un is Lost: AT: TECHNO OGY WAY
Dig Safe#: �
ISSUED ON 02-Aug-2011 AM NDED N. `��EX 1IRE ON. 02-Jan-2 12
TO PERFORM THE FOLLO&ING W RK
NEW(2) STORY OFFICE BUILDING/43,000 SF PER OR BLDG TO7fNGj
-ENG FRED STEEL. G ERAL
OFFICE SPACE AND LABORATO SPACE REASON FOR DELAY WOR A ITIONAL INF ATIONjbh
(CHECK FOR PERMIT WAS AL Y DEPOSITED FOR$18,125.33
POST T ISCARD SOITISVISIBLEF HE STREET
Electric Gas Plumbing Building
Underground: Undergr und: Underground: Excav mn:
Service: Meter: `,� Footings:
Rough: Rough: Rough: Foundation:
Final: Final: F' Rough Frame:
Fireplace/Chimney:
D.P.W. Fire Health
Insulation:
Meter: Oil:
Final:
House# Smoke:
Water: Alarm:
Assessor Treasury:
Sewer: Sprinklers: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF SALEM UPON VIOLATION OF ANY OF ITS
RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
BUILDING REC-2012-000260 02-Aug-11 x $0.00
I;GeoTMS@ 2013 Des Lauriers Municipal Solutions,Inc.
t
i
CITY OF SALEM
ROUTING SLIP
New Construction
Certificate of Occupannccy
LOCATION t'I l�GDATE
ASSESSOR DATE L\ 13
93 Washingto t.
CITY CLER E 4 -2 -J 3
93 Washington StAil
C
[120
LIC SERVICES ATE
Washin to St. —
ER DATE
Washington St.SS CONNECTIONDATEferson Ave
PLANNING DATE Z i
120 Washington St--.
CONSERVATION ATE J (�
120 Washington St. _
ELECTRICAL DATE
48 Lafayette St.
FIRE PREVENTION DATE
29 Fort Avenue
HEALTH L DATE 13
120 Washington66
BUILDING INSPECTOR ATE S
120 Washington St.
CITY OF SALEM, MASSACHUSETTS
f BUILDING DEPARTMENT
t 120 WASHINGTON STREET,3RD FLOOR
TEL. (978) 745-9595
FAx(978) 740-9846
KIMBERLEY DRISCOLL
MAYOR TrIoMAs ST.PIERRE
DIRECTOR OF PUBLIC PROPERTY/BUILDING COMNBSSIONER
Daniel Dillulo
16 Chrystal Street
Melrose Ma. 02176
Re. U.S Bio- Technology Way
Dear Mr. Dilullo,
Per the Construction Control Affadavit, submitted by you and dated June 12,2011, you stated in part
the following. "I shall submit periodically, in a form acceptable to the building official, progress
reports together with pertinent comments". To date, seven months later, this office has received no
reports, no communications or correspondence from your office. Work has proceeded to a point where
mechanicals are being installed and walls are being covered without any inspections by this office. It
has further come to our attention, subsequent to Planning Board and Con-Com approvals, that no Civil
Engineer has been involved in the actual construction of this project .
I am writing this letter to try to correct problems now rather than wait until the end of the project. I
look forward to a response from you and your plan going forward .
Sincerely,
C'.mqz�,
Thomas St.Pierre
Director of Inspectional Services/Building Commissioner
ZADE
ZADE ASSOCIATES, LLC
Consulting Engineers Mohammed Zade Ph.D., P.E.
140 Beach St., Boston,MA 02111 Muzaffer Muctehitzade M.Sc.,RE
Phone: (617)338-4406
Fax: (617)451-2540
Email ZadeCo(cbAOL.com
HVAC FINAL AFFIDAVIT
To the Inspectional Services Commissioner:
I certify that I, or my authorized representative, have inspected the work associated with
Permit No. , dated, Locus_,
U.S. Biological, Technology Way, Salem, MA Ward, on
several occasions during construction, and that to the best of my knowledge, information
and belief, the work has been done in conformance with the permit and plans approved
by the Inspectional Services Department with the provisions of the Massachusetts State
Building Code and all other pertinent laws, rules, regulations and ordinances.
I also certify that, with the completion of the work per the approved plans and provisions,
to the best of my knowledge and belief, the building is ready for occupancy.
Mohammed Zade 27233 2t ASN Of bfq�r
Engineer Mass Reg. No. Signature 9= \
Zade Associates, LLC o MoZApMEo
No. 27233
140 Beach Street, Boston, MA 02111 Oct 18: 2012 /?
Address Date �� �ECittr ,``Q/,
Then personally appeared the above named Mohammed Zade, and made oath
that the above statements by them are true.
—�
Before me,
_I J Q
120 1 L
M S;
?'^ NOTARY PUBLIC DATE SIGNED
Br v x = My commission expires:
21 2014
r 1F„y2!IlPlil`P�•
USS-'logical Packing List
Date Order#
reducing the cost of research 11/01/2012 108904
Bill To: Ship To:
Cosmo Genetech Co., Ltd. Cosmo Genetech Co., Ltd.
7FI, Jeil B/D, 275-16 SeongSu 2G 7FI, Jail B/D, 275-16 SeongSu 2G
SeongDong-Gu Seo, 133-831 Korea SeongDong-Gu Seo, 133-831 Korea
Customer Salesperson Department Ship Method Terms
US0231 Simon, Katie Customer's Acct. Net 30
Catalog No Product Name Size Qty Ship 8/0 Lot No Control No
"For in-vitro laboratory use only".
Biochemicals/Molecular biology-3822.00-2019
Antibodies-3002.10-909
/FED EX 4652-9134-6/email: overseas@cosmogenetech.com
I certify that the goods referenced on this invoice comply with the originrequirements specified for goods manufactured in the United
States and that further processing or assembly in a third country has not occurred subsequent to processing or assembly in the United
States.
Steve Kim Tel:+82-2-922-7307
We appreciate your business. Thanks!
See www.usbio.net for specifications on over 20,000 products
#Boxes Wt Blue Ice Dry Ice Tracking# Date Packed Checked
United States Biological• PO Box 261 • Swampscott MA 01907
Tel: 800-520-3011 • Fax: 781-639-1768 • chemicals@usbio.net • www.usbio.net
ZADE
ZADE ASSOCIATES,LLC
Consulting Engineers Mohammed Zade Ph.D., P.E.
140 Beach St.,Boston, MA 02111 Muzaffer Muctehitzade M.Sc.,P.E
Phone: (617)338-4406
Fax: (617)451-2540
Email: ZadeCo@AOL.com
PLUMBING FINAL AFFIDAVIT
To the Inspectional Services Commissioner:
I certify that I, or my authorized representative, have inspected the work associated with
Permit No. dated, Locus_,
U.S. Biological, Technology Way, Salem, MA Ward, on
several occasions during construction, and that to the best of my knowledge, information
and belief, the work has been done in conformance with the permit and plans approved
by the Inspectional Services Department with the provisions of the Massachusetts State
Building Code and all other pertinent laws, rules, regulations and ordinances.
I also certify that, with the completion of the work per the approved plans and provisions,
to the best of my knowledge and belief, the building is ready for occupancy.
Mohammed Zade 27233 � e
Engineer Mass Reg. No. Signatu a
Z MOHAMMED
Zade Associates, LLC NO- 27233
140 Beach Street, Boston, MA 02111 Oct 18. 2012 w ?Fclsr,n"�,✓ 1,;
Address Date
Then personally appeared the above named Mohammed Zade, and made oath
that the above statements by them are true.
Before me,
20( L
F, NOTARY PUBLIC DATE SIGNED,
1 .
My commission expires:
x ,gy l� r
aislsR'��r,
us logical Packing List
Date Order#
reducing the cost of research 11/02/2012 108924
k
Bill To: }n Ship To:
Johns Hopkins Enterprise ! J Johns Hopkins University
Email:crada@jhmi.edu j Attn: F..Belmonte, Mole & Comp athdf
733 N. Broadway, MRB Building, Rm 811
Baltimore, MD 21205 USA
Customer Salesperson Department Ship Method Terms
MC Simon, Katie FedEx St ON MCNISA .
Catalog No Product Name Size Qty Ship BAD Lot No Control No
A3340-35 Arg,SH3/SH2,Pab RbxMo 200ul 1
Blue Ice
P4090 Picante Sauce,Original 16 oz 1
200/Mary Rada 443 287 2953
crada@jhmi.edu
We appreciate your business. Thanks!
See www.usbio.net for specifications on over 20,000 products
#Boxes Wt Blue Ice Dry Ice Tracking# Date Packed Checked
` United States Biological • PO Box 261 • Swampscott, MA 01907
Tel: 800-520-3011 • Fax: 781-639-1768 • chemicals@usbio.net • www.usbio.net
ZADE
ZADE ASSOCIATES, LLC '
Consulting Engineers Mohammed Zade Ph.D.,P.E.
140 Beach St.,Boston,MA 02111 Muzaffer Muctehitzade M.Sc.,P.E
Phone: (617)338-4406
Fax: (617)451-2540
Email: ZadeCo@AOL.com
FIRE ALARM FINAL AFFIDAVIT
To the Inspectional Services Commissioner:
I certify that I, or my authorized representative, have inspected the work associated with
Permit No. , dated, locus,_
U.S. Biological, Technology Way, Salem, MA Ward, on
several occasions during construction, and that to the best of my knowledge, information
and belief, the work has been done in conformance with the permit and plans approved
by the Inspectional Services Department with the provisions of the Massachusetts State
Building Code and all other pertinent laws, rules, regulations and ordinances.
I also certify that, with the completion of the work per the approved plans and provisions,
to the best of my knowledge and belief, the building is ready for occupancy.
Muzaffer Muctehitzade 32579 �1 $
Engineer Mass Reg. No. Signat MuzavrEe
a .�
MUCTEHITZADE
ELECTRICAL
Zade Associates, LLC No.32s7s��� '
140 Beach Street, Boston, MA 02111 Oct 18, 2012 �oI�eE'�/���� .?,.
Address Date NA
Then personally appeared the above named Muzaffer Muctehitzade, and made oath
that the above statements by them are true.
Before me,
p\��UrTFr/j y�Fj� rt � C^ '�, 17n� /�/�
•.; , 1 4l.. ,�� L.yI I ,24� z-
x LLQ•�� 0'�+9y yr1 NOTARY PUBLIC' DATE SIGNED
My commission expires:
o;y ti
psi S'tfp•�,Y PUB�'i4'OQ \`�i�
It 20L+
i
ZADE
4
ZADE ASSOCIATES,LLC
Consulting Engineers Mohammed Zade Ph.D.,P.E.
140 Beach St.,Boston,MA 02111 Muzaffer Muctehitzade M.Sc.,P.E
Phone: (617)338-4406
Fax: (617)451-2540
Email: ZadeCo@AOL.com
FIRE PROTECTION FINAL AFFIDAVIT
To the Inspectional Services Commissioner:
I certify that I, or my authorized representative, have inspected the work associated with
Permit No. dated, locus_
U.S. Biological; Technology Way, Salem, MA Ward, on
several occasions during construction, and that to the best of my knowledge, information
and belief, the work has been done in conformance with the permit and plans approved.
by the Inspectional Services Department with the provisions of the Massachusetts State
Building Code and all other pertinent laws, rules, regulations and ordinances.
I also certify that, with the completion of the work per the approved plans and provisions,
to the best of my knowledge and belief, the building is ready for occupancy.
Muzaffer Muctehitzade 39362if
at;H c,r M'a
Engineer Mass Reg. No. Signatu
Zade Associates L.L.C.
140 Beach Street, Boston, MA 02111 Oct 18, 2012
Address Date
vs�
Then personally appeared the above named Muzaffer Muctehitzade, and made oath
that the above statements by them are true.
Before me,
C NOTARY PUBLIC U DATE SIGNED
My commission expires:
b e
United States Biological Corporation
P.O. Box 261 Invoice
Swampscott, MA 01907-2208 USA
781.639.5092 Fax: 781.639.1768 11/1/12 109493
URL: www.usbio.net
University Of California San Diego University Of California San Diego
Email: pilluslab@biomail:ucsd.edu Pillus Lab, Pacific Hall 2115
9500 Gilman Drive
La Jolla, CA 92093-0347
VISA Simon, Katie UPS Ground MCNISA
P3306 Peptone Y 500g 2 69 138.00
P4090 Picante Sauce, Original 16 oz 1 .00
P A I D NOV 0 2 2011
Pillus Lab 858 822 2443 . . - 138.00
pilluslab@biomail.ucsd.edu .00
in stock All states are responsible to pay directly,except MA Sales Tax.Thank you for your order! BEEN=
,; �,� 1900.
I
it.S>:'1 157.00
ZADE
ZADE ASSOCIATES, LLC
Consulting Engineers Mohammed Zade Ph.D., P.E.
140 Beach St.,Boston, MA 02111 Muzaffer Muctehitzade M.Sc., P.E
Phone: (617)338-4406
Fax: (617)451-2540
Email: ZadeCo P_AOL.com
ELECTRICAL FINAL AFFIDAVIT
To the Inspectional Services Commissioner:
I certify that I, or my authorized representative, have inspected the work associated with
Permit No. '`" , dated, locus,_
U.S. Biological, Technology Way, Salem, MA Ward, on '
several occasions during construction, and that to the best of my knowledge, information
and belief, the work has been done in conformance with the permit and plans approved
by the Inspectional Services Department with the provisions of the Massachusetts State
Building Code and all other pertinent laws, rules, regulations and ordinances.
I also certify that, with the completion of the work per the approved plans and provisions,
to the best of my knowledge and belief, the building is ready for occupancy.
Muzaffer Muctehitzade 32579Ljacc � uzaErEe ``'.
Engineer Mass Reg. No. Signat _� MUCTEHITZADE s
ELECTRICAL
Zade Associates, LLC No a27
140 Beach Street, Boston, MA 02111 Oct 18. 2012 °
Address Date
�`sSfONAIfa:'s'`cs"
Then personally appeared the above named Muzaffer Muctehitzade, and made oath
that the above statements by them are true.
Before me,
4�K '��G%!�teGn`�,e�acf�� r-� 120 2
NOTARY PUBLIC DATE SIGNED
c•- My commission expires:
F 4
A
le.6 2( I 2014
"�"[(1tfJt111i4A1\R
United States Biological Corporation
P.O. Box 261 Invoice
Swampscott, MA 01907-2208 USA
781.639.5092 Fax: 781.639.1768 7-117/1717-77109494
URL: www.usbio.net
NIH NIH-NCI Department
Email: whitetr@mail.nih.gov Attn: Shifand Dai, Building 37
9000 Rockville Pike, Room 6066
Bethesda, MD 20892
tw13-006305 on, Katie UPS Ground MCNISA
..- • E •
F5050 Fluoroorotic Acid 10g 1 199 199.00
P4090-10 Picante Sauce, XXX-Rated 16 oz 1 .00
P A I D NOV 0 2 2012
Tracy White 301 496 3771 - • • 199.00
• whitetr@mail.nih.gov .00
in stock All states are responsible to pay directly, except MA Sales Tax.Thank you for your order! . , , • 17.00
216.00
SENDER: COMPLETETHIS S ON COMPLETE THIS SECTION ON DELIVERY
■ Complete items 1,2,and 3.Also complete A. Signature
item 4 if Restricted Delivery is desired. 11Agent
■ Print your name and address on the reverse X (- ❑Addressee
so that we can return the card tO you. B. Received by(Printed Name) I I C. Date of Delivery
■ Attach this card to the back of the mailpiece, .
or on the front If space permits.
D. Is delivery address different from item 17 ❑Yes
1. Article Addressed to: If-YES,-enter delivery address below: ❑ No
0
Serviceryp�t7`i
G�.Cerbfled NI�iY O Express Mail
�oReglstered ❑Return Receipt for Merchandise
❑ Insured Mail ❑C.O.D.
4. Restricted Delivery?(Extra Fee) ❑Yes
2. Article Number
(Transfer from service label)
PS Form 3811,February 2004 Domestic Return Receipt 102595-02-M-1540
UNITED STATES POSTAL 1A 3• Z
• Sender: Please print your name, address, and ZIP+4 in this box
City Of Salem
Bulding Department
120 Washington Street
SC,alen-,, '\AA 01970
I . g213
212
°214
°215 °
216
°211
N °217
X210 °218
J 9 C-1
tlW °219 V 28 O�
} °2U8 °220
.230 NF
4127
207
2 °207 Npp '
/ °221 Rx pp'
�'d CB
°126 CB RIM=75.19
12" CPP/F] INV=72.4
°2C81 °222 0
°125 INV=72.9
°20 RIM=91.23 229
° .04 INV=88.2(IN) °223 Btm. of
INV=87.9(OUT) 02\ Concrete Structur DETENTION N
Q2 3 El=71.83
Grass r F 228 -BASIN
° °224 °227 10/ \ ' %�i wUA 4t
MAP 7 LOT 79 . 226 JF i qi
Wood25 0/ \ i //X 1 is CPP
206,743 sq.ft n / p X 1 '11 v
° _ _ 9 Bit. Conc. o Guardrail o �;/ J , Inv=76.4 23
4.75 acres i /
200 00 p
/ Parking _O B ,
� �
2 ' '/ /i �/ Emergency
Spillway °12
ro ,g3-t3\1 : "Conc.
o �Q rm \ a ° C\� ��°'' /��/' Crushed / / 18"CPP 121
N ° \ e /�.i / /� Stone // In v=71i 5
o,,3 / �/� i/// 120
/
O aI
RIMy91.95 - ,� 1�1�� /�/i' / I o _`!°�' cyj I19
ilP1V=86.O(IN) 1 Vim' ( ( ( grus e
\ .6 INV=85.7(OUT) X11 \\�\ ,�� '1. Sts 10U
Concrete , 1 - /-
O F 12 CPP �cl\6; , ��
/ Loading - o
\90\ \ : A
Dock Inv--81.7 ' °
101
C ` �i Rip-Rap100' BUFFER E1-94.35 D102crRIM=92.02NeI-94.28
_ _ INV=84.0 ° 03
m c`^6 12 CPP
9 114 °'"104
\ \ p / l� ��\ \ Inv=80.4 5
97 Roof 1+ :gear `�_ / I J /( ° 106
i CB3 ° O / Drain \Gon // \ 1\
RIM=92.99 r; l y / \ \ DMH1 ° 11 5. 00
Q Trench (Typical) U \ \ 0 107 0-
Drain 5
INV=89.9 DMI u \ RIM=90.33 \
Rim=90.21 ;., �, I cp \ \ \ INV-84.5 1N FROM CB)
2 Inv=89.5 / \\ o.�c o I \ INV=8.�1�f� FROM DMf/dt CB8
4 X\
DINV=83:
0
/
i
� BUILDING � ° RIM=84.44
CO INV=80.8(IN)
w\, ° Concrete U.S.BIO INV=80.9(OUT)
Bumpers 0
oof
ppk a�cA /
Drain O,. ho
\ PI (TypLool) / Gp, \I ' ��\\�� o �j 0 , / ea
Trench /' / �\ , \\ \ 7� m
i � e��oQ RIM= �
' O - I Drain coe o Q / / Grags\�_ \ l Om, CO
� , Grori IN 6
eta . \Cd Rim=92.28 to - / . o -) 1 \\ / /
0 p
Inv--91.6 �� i / 03 , I \ G D
S 0 Bit. Co c. l /
\� y- pw Parkng
9 0 o, R=230.03 i
oncrete t � •o �
> Lo ding .a� G`�t ; l/ / �; �` Ac L=87.41'
�\, �, o k moo• ewe t��P // / / /" 11 / n - - -
�:. ` of a �/ i /�
Rip-Rap O S �. Concrete o� G°c %� i / ' , / / orae DMH5
Retaining ,t. Conc. {' Bumper / / //H' RIM=80.61
.Wall � P rking � � �. --- ,�., O � Gras�e% � __ -_ INV=74.5 .
Pipe / y� / /'�� ® '\ S62'41'08"W
9 B lard RIM=90.81
' 9` wv/ ' ,
ypi al) \ O / /� 7 275.86 INV=84.3(IN)
N5100'43"W \ ��D D ( � �cl INV=84.1(OUT)
. 28 14'
` MFP, � G
DMH4 \\ \® o
RIM=94.41 O m
LEGEND Nv=87.s Pipe
Bollard i Y
wV N WATER GATE (Typical) 77 .1
Granite
Sloped
GG GAS GATE Edging DMH3
HYDRANT INV=85.8(IN FROM DMH4)
CB CATCH BASIN INV=86.6(IN FROM CB)
13
® DRAIN MANHOLE CB5 INV=85.7(OUT) AS-BUILT PLAN
E00H ELECTRIC MANHOLE4 TECHNOLOGY WAY
RIM=91.62
Os SEWER MANHOLE wv=Ss.4
SALEM, MASSACHUSETTS
-II- SIGN
®H ELECTRIC HANDHOLE Prepared B
P y
0
CLEANOUT
� `aOf LeBlanc Survey Associates, inc.
FLOW
ARROW o161 Holten Street
� Rs
TREEBea Danvers, MA 01923
LIGHT POLE plp•3�3N �'
(978) 774-6012
PROPERTY LINE
-
_90 - - CONTOUR LINE December 17, 2012 Scale: 1 "=40'
WOOD GUARDRAIL
STONE WALL HOR. SCALE IN FEET
D UNDERGROUND DRAIN LINE 0 40 100 200
Engineering Alliance, Inc.
Civil Engineering&Land Planning Consultants
January 31, 2013 194 Saugus,MAS01906 Portsmouth,NH 1950 03801
3801
Tel:(781)231-1349 Tel:(603)610-7100
Fax:(781)417-0020 Fax:(603)610-7101
Mr. David Knowlton, P.E. Re: EAI Project#: 12-39501
City Engineer U.S. Biological
City of Salem 4 Technology Way
120 Washington Street, 4th Floor Salem, MA
Salem, MA 01970
Dear Mr. Knowlton:
On behalf of our client, U.S. Biological, Engineering Alliance, Inc. (EAI) is pleased to submit the
following for your review regarding the above referenced project:
• One (1) copy of a plan entitled "As-Built Plan" prepared by Leblanc Survey Associates,
Inc. and dated December 17, 2012.
• One (1) copy of a letter by Roome & Guarracino, LLC Consulting Structural Engineers
dated January 21, 2013.
Representatives from EAI have been on-site at various times since June, 2012 to witness
construction activities at the subject property. Based on our review of the enclosed As-Built
Plan and inspection of the site, we find the project to have been constructed in substantial
compliance with the approved plans, Planning Board Decision and Order of Conditions issued
by the Salem Conservation Commission.
The As-Built plan illustrates some deviations from the approved plans; however, based on our
review, we feel that overall the plan is in substantial compliance with all approvals and generally
accepted engineering practices. The deviations include the following:
• CB-2 shown on the approved plan was eliminated and replaced with a high point and CB-
3 was shifted to the north. Although this results in a slight change to the grading and
drainage, all storm water runoff generated from the site is captured on-site, treated and
discharged to the proposed storm water detention facility. The storm water detention
facility was built in accordance with the approved plan. In addition, the slopes of all
drainage pipes meet or exceed the designed values (many were designed at 0.05 ft/ft,
and most were constructed at 0.08 ft/ft). Based on our review, the storm water
management system is functioning as designed and meets the goals of the original
drainage design.
• The transformer and generator were relocated from the area shown on the approved plan
(South side of building)to the south side of the parking lot. The relocation of this
equipment does not appear to have an impact on the layout of the site. The additional
parking spaces that were added to the rear of the building offset the spaces that were
lost due to the relocation of the generator and transformer.
• The landscaped island to the rear of the building is smaller than the previously approved
plan. Although this area is smaller than shown on the original plan, all storm water
generated from the site is captured, treated and discharged to the down gradient storm
water facility. The storm water detention facility has ample capacity to handle this
modest increase in impervious area.
Mr. David Knowlton, P.E. Page 2 January 31, 2013
• A stone wall was constructed on the northerly side of the site in lieu of the modular block
wall and a 1:1 stone slope was constructed on the south side of the parking lot in lieu of
the proposed ledge cut. The stone wall and rip rap slope were inspected by Roome &
Guarracino, LLC Consulting Structural Engineers and determined to be structurally
stable and adequate.
Overall, the site was found to be stable, well constructed and functioning as the original design
and approvals intended. We are hopeful that upon your review of the site and this information,
a recommendation for a final occupancy permit may be granted for this project.
Should you have any questions or require additional information, please feel free to contact me.
Very Truly Yours,
ENGINEERING ALLIANCE, INC. OF MAS
ff G
RILHf.RD A.
Richard A. Salvo, P.E.
Principal 9OFFS
SloPPILE
Copy to: Salem Planning Board
Salem Conservation Commission
Warren Shore --Applicant
EAI File#: 12-39501
ROOME & GUARRACINO, LLC
Consulting Structural Engineers
48 Grove Street Somerville, MA 02144
Tel: 617.628.1700 Fax: 617.628.1711
January 21,2013
City of Salem
Inspectional Services Department
Mr. David Knowlton,PE,City Engineer
120 Washington Street,4bFloor
Salem,MA 01907
Reference: Review of New Stone Retaining Walls
at US Biological
4 Technology Way
Salem,MA
Dear Mr. Knowlton:
The office of ROOME & GUARRACINO LLC has been retained in order to review the stone
wall construction at the above referenced project address. The review is based solely on our
visual observations made on site, as well, as conversations 'and discussions with the general
contractor and site contractor in charge of the wall construction.
After careful review of the walls in place and the methodology of construction and back-filling
operations, it is our professional opinion that the walls appear to be stable, safe and built in
accordance with the applicable provisions of the Massachusetts State Building Code 8th Edition.
Should you have any questions or require further assistance,please feel free to call me.
Very truly yours,
ROOME&GUARRACINO, LLC
ST71 OF R9
CARMINE�o�
GUARRACING "
STRUCTURAL w
No.401
<9OF.Q�Ot .Ci X44-
fs NO��
Carmine Guarracino,P.E.
Partner
cc: Mr. Richard A. Salvo,P.E.—Engineering Alliance,Inc.
7 s
x '
}v e
IT
I LIC
%
r i Q N�r�¢•
RM
C' Moi u
VIII
Ali
'g'" '• • ..ori{ '
YV nrcmifarPn9raT Phmtln9 eM �.
Icesq bPw_oc aik M.ms iaNgs '�
16 Crystal Street, Melrose, MA 02176 781-662-3498 (fax)781-662-8389
January 8,2012
Mr.Thomas St. Pierre
Director of Inspectional Services
120 Washington Street
Salem, MA
Re: US Biological
Mr. St. Pierre,
I received your letter regarding the reporting of construction as required by the Construction Control
Affidavit. I have visited the site at frequent intervals(sometimes more than weekly)since last May and
have kept written records of those visits. I will assemble those reports and send them to you immediately.
While we have made some internal floor plan changes to accommodate the Owners program the building
is substantially the same as shown on the Permit drawings. In all cases in the course of my visits the
work observed has been proceeding in accordance the plans and specifications and entirely in accordance
with the Building Code.
By copy of this letter I will refer you to Peter Varone and Peter Holland to confirm the actions required by
a Site Engineer. I know that Engineers have been on site to lay out the site and utilities, confirm the
foundation location and dimensions and lay out the site perimeters and grading.
I apologize for not getting these reports to you sooner.
Sincerely,
Dan DiLullo
c.Peter Varone
Warren Shore