Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
295 DERBY STREET - SIGN PERMIT
295 Derby Street Speedway Commonwealth of Massachusetts Citv of Salem 120 Washington St,3rd Floor Salem,MA 01970(978)745-9595 x.5841 'n+x:noa Return card to Building Division for Certificate of Occupancy Permit No. a 5-686 PERMIT TO BUILD =EE PAID: $0.00 DATE ISSUED: 7/10/2015 This certifies that PHILADELPHIA SIGN COMPANY has permission to erect, alter, or demolish a building 295 DERBY STREET Map/Lot: 340442-0 as follows: Signs SIGN PERMIT AS APPROVED FOR: SPEEDWAY Contractor Name: DBA: Contractor License No: 7/10/2015 Building Official Date This permit shall be deemed abandoned and invalid unless the work authorized by this permit is commenced within six months after issuance.The Building Official may grant one or more extensions not to exceed six months each upon written request. All work authorized by this permit shall conform to the approved application and the approved construction documents for which this permit has been granted. All construction,alterations and changes of use of any building and structures shall be in compliance with the local zoning by-laws and codes. This permit shall be displayed in a location clearly visible from access street or road and shall be maintained open for public inspection for the entire duration of the work until the completion of the same. The Certificate of Occupancy will not be issued until all applicable signatures by the Building and Fire Officials are provided on this permit. HIC #: "Persons contracting with unregistered contractors do not have access to the guaranty fund"(as set forth In MGL c.142A). Restrictions: Building plans are to be available on site. All Permit Cards are the property of the PROPERTY OWNER. Permit Number 4 ( �._: — . >Z•. APPLICATION FOR PERMIT TO ERECT A SIGN18) Co'i 5 NOTE: BUILDING PERMIT MUST BE OBTAINED BEFORE SIGN IS ERECTED DEPT. OF PLANNING& a Location, Ownership and Detail Must Be Correct, Complete, and Legible M f„'!'Ty pa/ELOPI.!_^'T una Salem, Massachusetts 5 L4 I ZDI S Date To the Building Inspector: The undersigned hereby applies for a permit to%Erect, Alter, o Repair a sign on the following described buildings: �!- District C ❑Urban Renewal Area ❑Entrance Corridor 29 5 P—B Y STeeL T 5 ❑Historic District D None . ' HCSS CD2POK.4TION ` ' Is Telephone 732 -7S'0 - ( Z 1 floor CO,4S 5-rA-nON gZ • - C0eP0eAnO'u 5PiZW4 2 floor Address ONL HESSA,gj,4 - WOOD9e10&6 NU- 3 floor Telephone 32 750- (0192 4 floor E-mail HA LA LM_ N 841:1.1 e SOL��w4 . c0 M How many businesses are in the building? ONE If a corporate body, name Frontage of responsible officer k-A. (Au.TeNa4GHeQ PNIL400,014 .SI(oN OL)A404;1I Building linear feet Caxstrudion Sups License No 08(-7010 EyYI N 6 'C.ONNL--LL Applicant's Space(if multi-tenant) _ linear feet Address linear feet 01 W. $l�rNlO 64iZOW $T. A(.e+ 2a N Properly Telephone C oMOT, SSG •7 Z -il Sign Permit to E-mail W00 0 ws G N ❑Sign Owner ❑Sign Erector Other- - . . -. . ... MTOral I gem_0l7 Sint -pi Sin2C- -()7, Sin3 o Surface Q Surface Surface 4 ❑Right Angle to Building u Right Angle to Building o Right Angle to Building (7 ,41 Free Standing PEr-A c6 �, o Free Standing o Free Standing U D Awning y o Awning ❑Awning o Portable(A-Frame) o Portable(A-Frame) ❑Portable(A-Frame) AW Other(specify)I41"Wfm 445 alu:.R.feD ❑Other(specify) ❑Other(specify) Sign Materials LLJN F,11Cg Sign MaterialsAu L44IACA'VL.[C. Sign Materials AwA4 Aue,Vu c Sign Dimensions 91'19 k `IB I8 Sign Dimensions ,k it tit IZ, Sign Dimensions 2&„ >< f(, � L„ N O Sign Area 32 sq ft Sign Area 2 s ft ft 5 Sign Area 2 5 p o Sign Height(if free standing) '/ Sign Height(if free standing) Sign Height(if free standing) 4 E.1015-TIQ(o• NO aVN(vE 7115 ftoN.T. — Estimated Cost of Net Work $(P, 000 p0 Ge: oS.Oo Exilsting Signs IYpe S'gn Area To Be Removed? Sign Owner Surface 3 F-W5rI1.YoUmu 51r'Ns as allff sq ft b yes o no E{-�¢, t4u,-mNgW,y_-e . _&Z 4rL46 yrs `FI o Right Angle to Building sq ft ❑yes ❑no _ ^f Free Standing (ht-P4 ce) 'Z`sq ft o yes `er no 1 fA� n 0 r s ze Re sen ve ❑Awning sq ft o yes o no V I a Orther(specify) sq ft o yes o no ?property Owner ,c. HA, G4u,T&N3�W t- See417c4LHW>' e 0 P riInternal Review ng&Community Development Department Historical Commission Approvalsh Building Inspector 71`3 Dsn4n D w City of Salem Sign Permit Application Worksheet RECEIVED INSPECTIGNAL SERVICES 18-Jun-15 Speedway(former Hess) 7�15 �u _q P 4� DLI 295 Derb Street {� Zoning(res/non-res) B5 Entrance Corridor(YIN) N Lot frontage 103 feet n Building or tenant frontage 60 feet —J #of businesses on site 1 Bldng dist from street center 140 feet U I Multiplier 1.25 Building and:BladsiSi rts:; maximum area permitted 75.00 sq ft total proposed sign area 55.43 sq ft �J sign 1 length 136.50 inches Ir height 26.00 inches sign 2 length 136.50 inches height 26.00 inches sign 3 length 26.00 inches height 34.00 inches sign 4 length 0.00 inches height 0.00 inches sign 5 length 0.00 inches height 0.00 inches Freestanding Signs . ... ,.. maximum area permitted 32.50 sq ft(per side) maximum#of signs permitted 1 signs maximum height permitted 12.50 ft tall sign 1 proposed sign area 32.33 sq ft length 48.00 inches height 97.00 inches proposed sign height 0.00 ft(approx) sign 2 proposed sign area 0.00 sq ft length 0.00 inches height 0.00 inches proposed sign height ft Application meets standards set forth in the Salem Sign Ordinance Yes Recommend approval Yes SRAIDRB approved. a. Sinn Permit Consultant's HAZEL WOOD HOPKINS HEATHER HOPKINS DUDKO 2 Phoebe Way Phone/Fax 5o3-856-7332 Worcester,MA 01605 hwoodhopkins@charter.net i SERVICES: • Sign Permits • Code Research and Analysis • Sign Proposal Analysis. • Zoning Board of Appeals Hearings • Design Review,Historic and Planning Board Meetings • Permit Number �0 APPLICATION FOR PERMIT TO ERECT A SIGN s f� NOTE:BUILDING PERMIT MUST BE OBTAINED BEFORE SIGN IS ERECTED c Location, Ownership and Detail Must Be Correct, Complete, and Legible 3 Salem, Massachusetts Date To the Building Inspector: The undersigned hereby applies for a permit to ❑Erect, ❑Alter, ❑Repair a sign on the following described buildings: Districtet Addres Zoning o Urban Renewal Area o Entrance Corridor o Historic District c None Telephone 1 floor • 2 floor Address e floor Telephone 4 floor E-mail How many businesses are in the building? ff a corporate body, name Frontage ofresponsible officer Building linear feet Qnstruction Sups Doerlse No Applicants Space(if multi-tenant) linear*feet Address Property linear feet Telephone - E-mail o Sign Owner o Sign Erector o Other. Si in Sign 2 Si n 3 Surface D Su ce o S ce E3 Right Angle to Building D Righ Is to Building D Right gie to Building D Free Standing D Free Sta 'ii ng o Free Sta ing D Awning D Awning o Awning D Portable(A-Frame) ❑Portable(A-Fra ) D Portable(A-Fr e) o Other(specify) o Other(specify) o Other(specify) Sign Materialss I UC Sign Materials Sign Materials Sign Dimensions u 3 Sign Dimensions Sign Dimensions Sign Area Sign Area Sign Area s ft s ft ft Sign Height(if free standing) Sign Height(if free standing) Sign Height(if free standing) Estimated Cost of Net Work sting Signs Type Sign Area To Be Removed? Sign Owner o Surface sq ft o yes ❑no D Right Angle to Building sq ft o yes c no o Free Standing sq ft o yes a no Sign Owner's Authorized Representative D Awning sq ft o yes o no o Olther(specify) sq it oyes ono Property Owner Planning&Community Development Department Historical Commission Building Inspector osnatore. Salem Redevelopment Authority SRA I PSalem Redevelopment Authority Proposal Vow,00 FE tl�July 8, 2015 295 Derby Street (Speedway (former Hess)): Discussion and vote on proposed installation of signage SRA Decision At its meeting on July 8, 2015, the SRA voted 4-1 to approve the June 24, 2015 DRB recommendation to approve the proposal to erect signage at 295 Derby Street (Speedway). This approval also includes the use of digital signage for pricing as presented to the SRA on plans dated April 10, 2015. Recommendation At its meeting on June 24, 2015, the DRB voted unanimously (7-0) to approve of the proposed signage at 295 Derby Street (Speedway (former Hess)) per the plans and drawings dated April 10, 2015 —the DRB does not recommend approval of the digital pricing on the free standing sign as shown in these plans, but rather a "higher quality" specification of digital signage, or to keep manual pricing. Staff Comment for July 8, 2015 SRA Meeting The applicant has not provided a separate specification for the digital signage that will appear on the freestanding sign and has no intention to do so at this point. You may consider the proposal as-is; require the applicant to return with an improved specification for digital signage; or ask that the signage remain manual as it currently exists. Proposal The applicant proposes to reface and replace existing signage. All proposed new signage will be the exact same size square footage-wise as the existing signage, except for the building sign to be placed on the convenience store, which will be six (6) square feet as opposed to a current 18 square feet. All existing signage is internally illuminated, as is all of the proposed new signage. The signage along two sides of the gas station canopy are internally illuminated channel letters. One significant change that is being proposed is the use of LED for the prices on the freestanding sign. Salem Redevelopment Authority Staff Comment The proposed signage is well within the square footage allowed by the City's sign ordinance for this location. As the Design Review Board is aware, the City's Commercial Design Guidelines document does not recommend the use of internally illuminated signage within the downtown or along designated entrance corridors. That being said, the Design Review Board has the discretion and authority to recommend such signage as appropriate to the Salem Redevelopment Authority. Moreover, the City will typically honor the replacement of previously approved like non-conforming signage. The City will typically not approve LED signage, however, exceptions have been made for gas stations around the City because of the variable nature of pricing and because of concerns expressed in the past by applicants regarding worker safety (having an employee remove and change numbers, sometimes using a ladder. The Board has the discretion to disallow this portion of the proposal as well. PHILADELPHIAS3'CN SlfNCaH. LO:( YY)p94b4f�P1 !)-1.1�{ %IlAdeIPhfa$ignCor0pbY • 107-%stsprivo tb*$t. RaTmgra N) OW SW2480 Speedway 248o Speedway Store 0002480 295 Derby St Salem , MA i By nly:signatur8 bt hwt Ihercby reprownt-tBaf T:iwihb o'wnev aM0 00 intlicatod 006 or 01� duly nuthb4Z4 1,fhe Lease to 8ranf authorizaiion for Phila+tolpltia Sign Company,and/,orr theirttub contractor lioapply f0itporra is and install nwsignageAffhe above referenced loeation.. LANDLORD APPROVAL — SiflPtttite - E �� Pt8Hm4iw� Date. Yie M43f4 WL Pte' Wrlc eznitil I&LAuK►�6Ac4Q 6 PWAy,roM�t Aciilrest SQOCO W A*( Lk Rlidae )$1. —790 - to 111— nwd 14e65 PLArZA- W 000 5Wi04*4 NJ Moll Retntn Form to: PbUdelphia Sign Company 101-Wed Spring Garden St Pglmyya,NJ 08063 or FAX to 856-829-8549 attnr Barbara McSweeney or:efirYd U bincsweeney.@phhitdelphiasign:eom 4 ®i FREESTANDING ILLUMINATED PYLON WITH 2 PRICE DISPLAY rIFFDH�— ,IBS'(• nFlrla�' lB IQ� -y SCOPE: 32 41334 '1^-m�- -REFACE EXISTING PYLON I tJ S T a u ,1' -NEW 2 PRICE LED DISPLAY(UNL/DSL) I f`7 G7 11 f•- 97-1/8"R x 48-1/8" W with 12" LED Unit I t I ■ ■ 1 � �1��g ■ �. .■ y�eJ� ,I -- i rr. Speedway °wc er is -oA. 4110115 Dare Re SIGN By _ - - P H L A D E L P H A S I G N °e. sw24e0-spdwy Store 000zaeo °w°NUMB61181 11 0:1 295 Derby Street -seen sale.,MA 2 ..x.. ll o r . rh ""I, _ _ alas r�r+� Htss" Itirr. 1LL1..+lu,1VrM CANOPY FRONT ELEVATION q BEFORE 231t IVI 1I�o CZ4 ,� SCOPE: -RESTRIPE CANOPY WITH T RED VINYL 3M 7725-83 GERANIUM 26"H ILLUMINATED LED"Speedway'CHANNEL LETTERS nf / q I 11'4-1/2" AFTER 2ro1 j X 11 J I 1 Z,v C Z4 PKWw ti Speedway t � t .Speedway. _ - ILLUM CHANNEL LTR ELEVATION - ... SCALE:318"=1'0' ' - Speedway owc er J5 onre 4/10/15 w*[ xenslov PHILADELPHIA 5 I G N SW2480-Spdwy store 0002480 "°" 661181 295 Derby Street srieEr Salem,MA 3 11 ,S l'.-.AI3LEN Sr.I+ILN.,F313: ype• r @•.i�_e3A-n.i 9ci.y.n.q.,�y.V.R I3 IiM1p i'vevip'Iseeglvuynrm+ Ous7{,5mv • R -tz_ INT( q J LAtA.A.LIA3, 4T2,>, 0 CANOPY LEFT ELEVATION BEFORE 2s11k 7'1`A e2S� O -` SCOPE: -RESTRIPE CANOPY WITH 7"RED VINYL 3M 7725-63 GERANIUM 26"H ILLUMINATED LEDwa `d C HANNEL LETTERS S ee I pp 11 442" AFTER 2Li SpeedwaySpeedway 'Speedway' ILLUM CHANNEL LTR ELEVATION 3- ZS SCALE:3/B"-1'0" most .�-.., " Ane Speedway owc-al is bIt 4/10/15 FAIL ReasFN e. _ n PHI LADELPHIASIGN AFDIII, SW24e0-Spdwy Score 0002460 °^°" B61161 ' r 295 Derby Street Salem,MA sneer 4 HESS EXPRESS BUILDING BEFORE ... SCOPE: - -PAINT GREEN TRIM SW 4081 SAFETY RED -PAINT TILES'HESS"RETAIL GREY REMOVE'NEON'HESS EXPRESS IN VESTIBULE 1 ' - -REMOVE'HESS EXPRESS-AND INSTALL 2B"ILLUMINATED BADGE SIGN u � AFTER C L ` 36 N < "Speedway - - ILLUMINATED BADGE SIGN SCALE:I'=1'0' Speedway TRE AWG BY B !$ BATE 1OAiE Rc'VISION BY PH 5 p p _ ILADELPHIASIGN swz4eo-spdwyStore 0002aeo ° °"° a11811e1 295 Derby Street EeT Sale ,MA -v� Salem, 5 r ENGINEERING SHOP SQUARE FOOTAGE:6.14 VINYL LAYOUT ROUTING/KNIFE Ir H I L AD E L PH I AS I GN lar W.Mow Jim,e.e von Pnlmyn.N.wJmry oases d.ea GENERAL SPPhone:ii'sECIFICATIONS r.e aM.eel.Le SINGLE FARE WALL SIGN ww..ynueexlPnlwon.w. 2'aD• 1 1n•— CABINET: 2'-3314" 1/4"� 3" Fabricated With 063-Thick Returns With 3mm Compbantl CUSTOMER: ' FACE: SPEEDWAY 4•Radius 1/8-Pan Formed And Embossed Clear Acrylite SG With Second Sudors Translucent Vinyl,Baa Spayed White. JOB NUMBER: ILLUMINATION: V Retainer White Bitm LED As Required, SIGN TYPE: 114•Embossment ELECTRICAL: SW.26.BADGE 120 Volt 20 Amp Primary Electric Circuits. Aluminum Cabinet MOUNTING: LOCATION, erJ And Retainers Mleniceten l Fasers As Requiretl Per Well CansWNen. Painted Red. N P2 COLORS: N Copy untl Arlon hits 2500-163 Poppy Red DATE Pan FormEmbossed F Ropy PMS White Embossed Face. RetumsAM Retainers sw 4081 serery Rea 01/1512015 1!51 Cabinet SW 4081 Safety Red DRAWN BY: All Signs Equipped With U.L. JTR Approved Disconnect Switch As Per NEC 600-2. ANCHOR SCHEDULE REVISION: Numtr. Dew. By. WALLMATERUIL ANCHOR TYPE OTY or SPACING Attach To Existing Wall Surface 1/4'Threaded Rods WIN Min. SHEEP, eNs s®r SaoWitNon-Corrosive Hardware. 2"Embetl In Epoxy Min.(3)Total OF 1 See Chad Below Far Hardware _ To Suit Mounting Conditions. Concrete(3do)or 114"Tapoons(or Equsl)With FRONT ELEVATION Hollow Masonry 1,15"Embed. Min.(3)TDral DWG NUMBER: SW.26.19ADGE SIDE VIEW 318'Expansion Arrchprs With 26"SIF Batlae Sion SCALE:1-1/2'=I'D' 3.5•Embed. Min.(3)Total ENGINEER SEAL: SCALE:1-1/2"=1'0" 112"Plywood 114 Toggle Bidts. Min.(3)Total (No Access Behind) 1/4•Wood Scows Or Ta,x ons.Full Embed. Min.(3)Total Estimated Electrical Los Metal Studs Or ai4 Ms Ml Screws To Min.l8ge Min. 3)Total (2.0)Amps @ 120 Volts l { Metal Panels Steel Or C90-Aluminum Electric ReWintc P�.R�11�f ( ) (1)20 Am 120 Volt Circuits 1V { Hollow WSII 1looking Salts To Sold Min. 3 Total (Stocking Nall Blocking Behine. STANDARD WALL SIGN NOTES 1. Sufficient Primary Circuli In vicinity Of Sign 1{r By Others. 2. Final Primary Hook-up By Sign Idea ler. Mxz oasax vnxU SPEEo es xex Where AllDwed By Loral Codes. ExPosURE C 3. Sign Shall Be U.L.Listed. 4. Mounting Hardware By Sign Installer. amnxe wexdrn rw nw Note.:This zdlmNnaea rone memlloo., �.Monr..0 me repuirwe..of sw�p�.ow�s rn ...mvT Athos 6011m me Ni Electoral Rom anNm w other oloccle mpl moles. �11oe VrIx This Imlu0ea proper,grounding entl eonau,p of me SMn. m roux c.uvm, f.nsvus.a.roams I.on r.caa SQUARE FOOTAGE:24.56 ra PHILADELPHIASIGN 5- 70 Wm Scan Bank,sl.•e —— — i PalmBr•.H•w J•r•ry ON' PM1en•:161,11.11.1 Fax:BN.6BBe5aB rmx.pM1ll•tlelpMriBn.epn CUSTOMER: SPEEDWAY r JOB NUMBER: dwayN SIGN TYPE: .SpeeSW.CL.26.LED LOCATION: FRONT ELEVATION SIDE VIEW SW.CL.26.LED 26"TTW Channel Letters SCALE:V=T O" DAM: GENERAL SPECIFICATIONS SCALE:1"=1'0" 01/0912015 Jmm ACMComp66na CABINET: Bawg`ao Pane, . DRAWN BY: Channel Letters 5"Deep With 1"Red Jewelde Face Retainer.Returns Pre-Finished Light Gray. �y FRmewon JTR NOTE: TrmuTo Sa st yMaximum FACE: Seadr.grrlm mt EXNeoey Maximum 5" Amahtenorsms.sn Pand REVISION:ti, 1/6'Thick Pigmented Acrylic Faces ma j °"'�` ' ® CERTIFICATE OF LIABILITY INSURANCE ,01072014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND, OR ALTER THE COVERAGE AFFORDED BY THE POLIOS BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHOR® REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the poliicy(tes)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificare does not confer rights to the certificate holder in lieu of such endorsetnent(s). 02115-COS cT - USI Insurance Services LLC yGN B (844)874-0123 FnAX �Na (877)775-0110 75 John Roberts Rd Bldg C EaAa South Portland,ME 04106 !A %SS Terxy.MacLeod@nsi.biz ONSl1RHR AFF-0RdNG(AVERAGE 4 RPR A.I.M.Mutual Insurance Company 33758 INSURED Sign Co 'INSURER B: INSURER 707 R Spring Garden Street �Ixsu Palmyra, NJ 08065 INSURHRE: COVERAGES CERTIFICATENUMBER; REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE USED BELOW HAVE BEEN ISSUED To TI-E INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY RECUIREMENi,TERM OR CONDITION OF ANY CONTRACT OR 07HER DOCUMENT WTH RESPECT 70 WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TEWNS, EXCLUSIONS AND CONDMCNS OF SUCH POUCIES.UNITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. TYPEOFINSURIWCE ,�0 PDLCY NUMBER FOLLY ET-F POLICY LAS GENERAL LIABILITY EACH OCCURRHdCE S t NERCIAL GENERAL UABILnY OAMAC O ® S CLAINS2MPDE 0OCCUR A7®E]RPtMydna Pasini S PERSONAL&AOVIMIURY S GENERAL AGGREGATE S tI L AGGREGATE UNIT APPJES PER PROpUOTS-COMP. AGG S AUTOMOBILE RNBIIJTY NEDSINGLEOF S ANY AUTO BODILY INJURY(Pn Pte) S AL-OVYN® SCHrDULrD INJURY AUrOS AUTOS BODILY Per a=WerQ S WREDAUTOS NON OWNS) PROPERTYDAMAGE s AUTOS S F OG.,1REA04 OCCURRENCE S ACLAIMS MADE AGGREGATE '• S R�ER,gppN�FgZE�RgB�•1TpIOqN$ 5 WM RRIOYHts LWB¢trY YIN X *MAS OT4 A 1A im +I &MFB ❑N NIA VWC-100-6011076-20UA 10N0=14 1WI02015 ACCIDENTE 1.000,000.00 (ftnndatory in NR) ELD664SE-EAEMPLOYEE $ 11000,000.00 DMPo OF�'OPERATIONSI FL DISEa5E-POLICY U S 1,000,000.00 DESCRIPTION OF OPERATIONSI IDCAMONSI V@nCLES(Amen ACORD 101,AddR Orml RMaM55C WUI%R more Space is ralulmG) WC coverage applies to MA employees only CERTIFICATE HOLDER CANCELLATION Proof of Coverage SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 00000 THE EXPIRATION DATE THEREOF. NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHOR®REPRESENTATIVE nn n ©1988-2010 ACORD CORPORATION.All rights reserved. ACORD 25(2010i05) The ACORD name and logo are registered marks of ACORD Everbrite Date: July 291h, 2014 Re: LumiDigit II Sign Illumination To Whom It May Concern: Everbrite, LLC produces LED signs ranging from gas price signs to message centers. We design our products to meet and exceed our customer's expectations whether it's in its appearance, performance or specifications. Our dedicated Technical Center works constantly with municipalities to ensure our products adhere to the requirements set forth to ensure proper appearance along with public safety. One of the areas of compliance interest is the illumination of our LumiDigit 11 gas price sign. This stems from the concern caused by companies producing LED signs that maintain the same brightness throughout the day and night. This not only wastes energy but also makes the sign difficult and dangerous to read at low light conditions such as during the evening hours. Everbrite incorporates into its products, sensors that constantly evaluate the ambient light levels and automatically adjust accordingly based on the parameters assigned during the sign setup. With these sensors mounted on both sides of the sign, we can monitor and adjust the brightness levels on each side independently. The brighter the ambient light, the brighter the LED's must be to compensate for this higher light level otherwise the sign would be very dim or may even be perceived as being turned off during the day. Along the same lines, when the LED's are in a too-low brightness level during the day, the required time it takes to interpret the price increases and may cause drivers to dwell on the sign longer than necessary. In the 10 years of producing LED price signs and working with local jurisdictions, Everbrite has determined that the ideal safe nit level that's easy to read and interpret are those that are between 3000 and 4000 nits during the daytime and between 500 and 1000 nits during nighttime hours when used around ambient lighting such as street or parking lights. Our signs are configured so as not to exceed 4000 nits (cd/m2) during the brightest part of the day and are shipped out from our factory defaulted at the lowest nighttime setting to ensure we are adequately below requirements. To explain this further, our smallest digit emits only 300 nits (cd/m2) and our largest digit emits 400 nits at night when no ambient light is present. Please feel free to contact me with any questions or comments. Sincerely, Mark Erickson Product Development Manager 401 South Main Street, Pardeeville, WI 53954 Phone: 608-429-2121 Everbrmte lumiDigit 2-5 Mounting information 39213' DWK Size:12" —38.8130 M N.- Power Supply Required Per Double-Faced Sign: T Green:I SVDC,2 Output ... ... - ---------- v . ...........•. ... ... ... ... Red/Amber.1 0.50�2 Output ... ... r.:: M M Mwdmum Arnp Draw.3 amps All displays to be mounted from the Inside 4 r i;! face. Side Front Digit pans were engineered to be installed with 3/16"rivets.Hardmare required may change per location. Use holes in the side flanges of the pricefte to attach the displayto the sign using appropriate hardware Everbrite is not responsible for the mounting structu re or for the mounting hardware to attach to structure.Installer Baric must comply with all local codes. 37.750" Cable harnesses are supplied to route ——————-—- power and data connections. Refer to the Installation Manual,Shop drawings(if appricable),and Operations Manual for further information. N Recommended Vinyl Opening(DigttWf rdow) I'misheciView Regular Islu @)qq Diesel Front Back(inside) FREESTANDING ILLUMINATED PYLON WITH 2 PRICE DISPLAY ` O A�� BEFORE AFTER SCOPE: -REFACE EXISTING PYLON ,- -NEW 97-1/6T x 48.IM'W 2 PRICE MANUAL DISPLAY(UNL/PREM) I 'CT3 � F .. Speedway_. _ —_— mw a. is le 4!79/15 mn"u xecrnm�,oeuNuv"KE orsrur ., _ PHILADELPHIASIGN SW2480-5PdwySto..009zaeo °r*" 061181 .. .. 295 Derby Street F. Salem,MA uar/ 2