Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
7 POND STREET - BUILDING INSPECTION
74520 40@1 P4 DATE OF kWAIT FERMIT No. OWNER LOCATION 9/10/97 507-97 LEMONS REALTY TRUST 7 POND STREET (REAR) 1 STRUCTURE MATERIAL DIMENSIONS No.OF STORIES No.OF FAMILIES WARD COST WIIDfR 9/10/97 #507-97 SIGN PERMIT FOR "NORTH SHORE SMALL ENGINE SERVICE", DRAWINGS SUBMITTED. est. 200 fee 20.00 L.E.T F DATE OF PERMIT _ PERMIT NO. OWNER - ,.3 '+TION WELLING MATERIAL C', DIMENSIONS NO OF STORIES NO OFF"IL1ES WARD 'BUILDER COST '/ V U 0 OTHER BLDGS:�' /P QM�A,T�ERIAL OIM EN//SI'O/NSS NO LD OF STORIES r 6UIERf - 0"6 V POCKET FOLDER •"'• i PLAN NO.$HEF t k L . Unofficial Property Record Card Page 1 of 1 Unofficial Property Record Card - Salem, MA General Property Data Parcel ID 34-0287-0 Account Number Prior Parcel lD -- Property Owner C2 HOLDINGS,LLC Property Location 7 POND STREET Property Use Comm./Res. _ Mailing Address P 0 BOX 829 Most Recent Sale Date 511612014 Legal Reference 87490-508 City SALEM Grantor LEMONS REALTY TRUST, Mailing State MA Zip 01970 Sale Price 506,000 ParcelZoning B4 Land Area 0.341 acres Current Property Assessment Card 1 Value Building 104,000 Xtra Features Value Value 24,400 Land Value 225,300 Total Value 353,700 Total Parcel Building 153,700 Xtra Features Value Value Value 24,400 land Value 225,300 Total Value 403,400 Building Description Building Style Repair Gar. Foundation Type Cone.Block Flooring Type Concrete #of Living Units 1 Frame Type Steel Basement Floor Concrete Year Built 1930 Roof Structure Flat Heating Type Unit Heaters Building Grade Average Roof Cover Tar+Gravel Heating Fuel Oil Building Condition Average Siding Cone.Block Air Conditioning 0% Finished Area(SF)3459.2 Interior Walls Drywall #of Bsmt Garages 1 Number Rooms 3 #of Bedrooms 1 #of Full Baths 0 #of 314 Baths 0 #of 112 Baths 2 #of Other Fixtures 0 Legal Description Narrative Description of Property This property contains 0.341 acres of land mainly classified as Comm./Res.with a(n)Repair Gar.style building,built about 1930, having Cone.Block exterior and Tar+Gravel roof cover,with 1 unit(s),3 room(s),1 bedroom(s),0 bath(s),2 half bath(s). Property Images 1`. h lss §J Disclaimer:This information is believed to be correct but is subject to change and is not warranteed. http://salem.patriotproperties.com/RecordCard.asp 7/22/2015 CITY OF SALEM, MASSACHUSETTS BUILDING DEPARTMFNT 120 WASHINGTON STREET,3 FLOOR niNac�' TEL. (978) 745-9595 FAX (978) 740-9846 KIMBERLEY DRISCOLT_ MAYOR THOYLS ST.PIERRE DIRECTOR OF PUBLIC PROPERTY/BUILDING COMMISSIONER October 9,2008 R.E :7 Pond Street Lemons Realty Trust Thomas Lemons 7 Pond Street Salem Ma.01970 Mr. Lemons, This Department has received complaints regarding the activities that are taking place in the storage garages behind your property. Specifically, businesses that are recycling appliances without proper environmental controls. We are also concerned that several of the uses do not meet the Zoning Standard for an "Accessory garage"Per the state Building code 780 C.M.R section 115 a n Inspection is required. Therefore you are directed to contact this office upon receipt of this letter to arrange for an Inspection of the entire property. If you feel you are aggrieved by this order, your Appeal is to the Board of Buildings,Regulations and Standards in Boston. ThomasSrre 4*0 Building Commissioner/Director of Inspectional Services cc. Jason Silva,Fire Prevention, Councilor Veno SENDER: COMPLETE THIS SECTION COMPLETE THIS ON ON DELIVERY .11111 Complete items 1,2,and 3.Also completea Sign_ Item 4 If Restricted Delivery Is desired. !�' ❑Agent ■ Print your name and address on the reverse X Addressee so that we can return the Card to you. Received by(Prot d(Nams) C. Date of Delivery ■ Attach this card to the back of the mailpiece or on the front if space permits. SALE 1. Article Addressed 0 0. Is delivery address different from kern 14 ❑Yes I �c� �� r -y fYES,enter delivery address below: 13 No /�2YtiU"U ) ` i" 1 d v 11 -p� 14 Mail ❑Express Mall red 13 Return Receipt for Merchandise ❑Insured Mail ❑C.O.D. 4. Restricted Delivery?(Extra Fee) ❑Yes 2. Article Number (rranster from service label) PS Form 3811;February 2004 Domestic Return Recelpt 102595-02-M-1540 UNITED SAYB �-T245V' ;._X. MA 3.. ege+$�@e9�P9Pd XK18. PM >r.��fi✓pe o +aQ,.nad' • Sender: Please print your name, address, and ZIP+4 In this box CITY OF SALEM, MASSACHUSETTS BUILDING DEPART iMENT 120 WASHINGTON STREET,3° FLOOR TEL. (978) 745-9595 FAX(978) 740-9846 KIMBERLEY DRISCOLL MAYOR THONL-�S STYIERRE DIRECTOR OF PUBLIC PROPERTY/BUILDING COMMISSIONER June 20, 2006 Thomas Lemons Trustee 17 Ome Street Marblehead, Ma. 01945 RE: 7 Pond Street Zoning Violation Dear Owner: This Department has received and investigated a complaint regarding the use of your property. The complaint states the garages associated with your building are being used by a company that is stockpiling used appliances. The garages constitute a grandfathered non-conforming structure intended to house automobiles. The garages are considered an accessory use to the main house. They are not intended to be a warehouse or other business use. You are directed to cease and desist the use of the garage as a separate business use within 30 days upon receipt of this notice. If you feel you are aggrieved by this order or interpretation, your appeal is to the Salem Zoning Board of Appeals. Sincerely, �)W� s Thomas St. Pierre Building Commissioner Zoning Enforcement Officer cc: Jason Silva, Mayors Office FIRE ALARM LEGEND FIRE ALARM GENERAL NOTES G - - Symbol Description 1 . FIRE ALARM INSTALLATION SHALL COMPLY WITH ALL Sp Smoke Detector LOCAL CODES AND REGULATIONS AND BE INSTALLED U 120V Smoke Detector ACCORDING TO MANUFACTURERS INSTRUCTIONS: 0 So 120V Combination 2. ALL FIRE ALARM RACEWAY SIZES AND CIRCUITRY Smoke/CO Detector REQUIREMENTS SHALL BE IN ACCORDANCE WITH <#> CO Detector APPLICABLE' 24V+ "CODES AND MANUFACTURERS RETURN LooF <@> Heat Detector RECOMMENDATIONS 3. PROVIDE 120V 20A DEDICATED CIRCUIT TO CONTROL 24v- 0 Pull Station PANELS, POWER SUPPLIES, ETC AS NEEDED. CIRCUIT SLC CIRCUIT FROM CONTROL PANEL OR PREVIOUS DEVICE OWP Pull Station - weather proof BREAKERS SHALL BE EQUIPPED WITH LOCKS TO 24v+ PREVENT ACCIDENTAL SHUTOFF AND BE CLEARLY Horn/Strobe Unit MARKED "FIRE ALARM CIRCUIT" � 24V- 1 Horn/Strobe Unit - exterior 4. WIRING SHALL BE COLOR CODED ACCORDING TO ALL APPLICABLE. CODES AND SHALL BE MAINTAINED weatherproof TYPICALTHROUGHOUT THE ENTIRE SYSTEM C SS " /0 lel 11 SIGNAL Strobe Only Unit 5. ALL WIRING SHALL BE CHECKED AND TESTED TO ENSURE CIRCUIT WIRING MM Mini Horn THERE ARE NO OPEN OR GROUND CONDITION PRIOR TO ENERGIZING SYSTEM ©. Exterior Beacon 6. ALL STROBES SHALL BE SYNCHRONIZED AT THE END OF CONSTRUCTION Monitor Module MM 7. SMOKE DETECTORS HEADS SHALL NOT BE INSTALLED ORTS Remote Alarm Indicating & UNTIL AFTER THE CONSTRUCTION CLEANUP OF ALL Test Switch FS Flow Switch TRADES IS COMPLETE AND FINAL IN ACCORDANCE WITH NFPA 72 TS Tamper Switch PS Pressure Switch I RTS Remote Test Station FRCP Fire Alarm Control Panel ANN CEILING NO. REVISION/ISSUE DATE Annunciator PROJECT NAME © Fire Alarm Sprinkler Bell ARM Addressable Relay Module 6.. Minimum 7 POND STREET Remote Alarm Indicator SALEM, MA 01970 KB Key BOX FIRE CM Control Module FILE 7POND ST.DWG I® isolator Module DOOR DRAWN BY AMP Amplifier PULL B. G. ANNUNCIIATOR STATIONDATE APRIL 27, 2015 RB Radio BOX 5510° CHECKED BY APPROVED-2 r G. E. 130 1. M Subject to approval b Y an other FIRE authority havuig)w emiction U 33 r DATE IRE c1T�DsA �i�, urkili. APRIL 27, 2015 MASSALARM T- DDFN ,.,. �0 �UREALJ ; u _ ' , n n Y lk I YV��% + SCALE �I - HO-96 - 6 ONTROL - SO 4O CITY _ ._•�.?ROVED SOLELY FOR IDER'IONDPVIC9F • •/A TYPE AtvO LOCA1fON Of FIRE P, ALL FI'['p^DiE07;OC n'wnrvo4G�10V D4VIC�5 PANEL Fti LiE3iA /r-�\ MASTER , , T.Da 461 SHEET BOX FLOOR FA 00011111111111 0 EXAMPLE OF FI M DEVICE MOUNTING HEIG'-ITS r PAGE 1 OF 3 ---T — -- _ - T - - - - r ' : F A CP F 0 o D SD D � BATHROOM . BATHROOM I O O w O J � i O _ o i SD m o SD O - O NO. REVISION/ISSUE DATE. / \ SD S PR D OJECT NAME 7 POND STREET SALEM MA1 0 970 SD FILE 7 POND ST.DW G SD z DRAWN BY U B. G. DATE APRIL 27 2015 ANN f CHECKED BY G. E. DATE APRIL 27, 2015 F -W SCALE L SEC ]LINSTL N/A 0 N lu"' FLOOR DEVICES SHOWING SHOWIhTG DEVICES SHEET , i PAGE 20F3 - I r - -- - - - _7-- I II I ! I. I � 7 0 0 O i 0 0 SD SD SD D HD I 6 _ O # 6/ FA1 2 O 017 <SD SD SD SD F F #FA14/2 B- SLC NAC . � 9050UD NO.' REVISION/ISSUE DATE. i PROJECT NAME ANNII 7 POND STREET i 2 12V SLA SALEM MA 01970 FA14 4 FILE 7 PONDD ST. WG DRAWN BY B. G. - rt/ TO 20A-120VAC (DATE APRIL 27, 2015 DEDICATED CIRCUIT CHECKED BY G. E. DATE APRIL 27 2015 SCALE N/A RISER SHEET SHOWING DEVICES AND WIRING FA 2 1 I PAGE 3OF3