Loading...
210 ESSEX STREET - ZONING s � DECISION �C,S&ex i N— — GIT.Y OF SALEM: MA CITY OF SALEM GL€t-WS OfFIGE o PLANNING BOARD YOTPRIsQ Site Plan Review Decision February 10, 2004 Salem Five Cent Savings Bank C/o Ronan, Segal &Harrington Attorneys at Law 59 Federal Street Salem, MA 01970 RE: Pedestrian Bridge Site Plan Review Decision On Thursday, December 4, 2003, the Planning Board of the City of Salem opened a Public Hearing regarding the application of the Salem Five Cent Savings Bank under Site Plan Review for the construction of a two-story pedestrian bridge to connect 210 Essex Street with One Salem Green. The public hearing was continued to December 18, 2003, January 15, 2004, and February 5, 2004. The Public Hearing was closed on February 5, 2004. At a regularly scheduled meeting of the Planning Board held on February 5, 2004, the Board voted by a vote of six in favor(Power, Puleo, Weiner, DiGerommo, Sullivan, Collins),none opposed, to approve the application as complying with the requirements of Site Plan Review subject to the following conditions: 1. Conformance with the Plan Work shall conform with the plans entitled, "Site Plan, Salem Five Cent Savings Bank,"prepared by Hamwey Engineering, Inc., 14 Manning Avenue, Leominster, MA 01453 dated November 11, 2003, revised December 29, 2003; and"One Salem Green Bridge," prepared by Winter Street Architects, Inc., 209 Essex Street, Salem, MA, sheets A.0, A1.0, A2.0, A3.0, and SLI, dated January 14, 2004. 2. Amendments Any amendments to the site plan shall be reviewed by the City Planner and if deemed necessary by the City Planner, shall be brought to the Planning Board. Any waiver of conditions contained within shall require the approval of the Planning Board. 3. Landscaping Any proposed landscaping shall be done in accordance with the approved set of plans. 4. Signage a. All proposed signage shall be reviewed and approved by the City Planner prior to the issuance of a sign permit. 1'20 WASHINGTON STREET, SALEM, MASSACHUSETTS 01970 •TEL: 978.745.9595 FAx: 978.740.0404 ♦ WWW.SALEM.COM b. The applicant shall install temporary signs for the duration of the construction period, which direct pedestrians to Essex Street via the alleyway along the CVS building. Signs shall be reviewed and approved by the City Planner prior to installation. 5. Roof Run-Off The applicant shall place snow guard clips on the roof of the pedestrian bridge so as to prohibit snow from falling on the parking lot below. If snow continues to fall from the roof after the installation of the snow guard clips, the applicant shall provide an alternative method of preventing snow from falling on the parking lot to the City Planner for review and approval. 6. Lighting a. No light shall cast a glare onto adjacent parcels or adjacent rights of way. b. A final lighting plan shall be submitted to the City Planner and the City Electrician for review and approval prior to the issuance of a building permit. c. After installation, lighting shall be reviewed by the City Planner, prior to the issuance of a Certificate of Occupancy. 7. Construction Practices All construction shall be carried out in accordance with the following conditions: a. The operation of tools or equipment used in construction or demolition work shall occur in accordance with Salem Ordinance Section 22-2 (5): Construction and Blasting and between the hours of 8:00 AM and 5:00 PM on weekdays and Saturdays. No work shall take place on Sundays or holidays. The Planning Board will agree to changes in the starting time, at the request of the applicant and if approved by a formal vote of the City Council, as per the ordinance. b. Any blasting, rock crushing,jack hammering, hydraulic blasting, or pile driving shall occur in accordance with Salem Ordinance Section 22-2 (5): Construction and Blasting and be limited to Monday-Friday between the hours of 8:00 AM and 5:00 PM. There shall be no blasting, rock crushing,jack hammering, hydraulic blasting, or pile driving on Saturdays, Sundays, or holidays. c. Blasting shall be undertaken in accordance with all local and state regulations. d. All reasonable action shall be taken to minimize the negative.effects of construction on abutters. Advance notice shall be provided to all abutters in writing at least 72 hours prior to commencement of construction of the project. e. All construction vehicles and equipment shall be cleaned prior to leaving the site so that they do not leave dirt and/or debris on surrounding roadways as they exit the site. f. The applicant shall abide by any and all applicable rules, regulations and ordinances of the City of Salem. 2 g. All construction vehicles and equipment left overnight at the site must be located completely on the site. h. No Street shall be closed without prior approval of the Department of Planning and Community Development, unless deemed an emergency by the Salem Police Department. i. The applicant shall notify abutters at least 48 hours prior to the start of construction. 8. Construction Traffic a. All work shall be undertaken in accordance with the plan titled, "Salem Five Cents Savings Bank Construction Traffic Management Plan" and dated February 11, 2004 presented and submitted to the Planning Board. Any amendments proposed to be made to the plan must be approved by the Department of Planning and Community Development prior to implementation. b. The temporary construction fence shown in the Construction Traffic Management Plan shall be moved, if necessary, to allow free crane movement. Any relocation of the fence shall be approved by the City Planner prior to relocation. c. If necessary, the applicant shall restore all damaged roadways, driveways, and sidewalks to their original condition. 9. Salem Redevelopment Authority All work shall comply with the requirements of the Salem Redevelopment Authority. 10. Clerk of the Works A Clerk of the Works shall be provided by the City, at the applicant, his successors or assigns' expense, as is deemed necessary by the City Planner. 11. Salem Health Department All work shall comply with the requirements of the Salem Health Department, if applicable. 12. Office of the City Engineer The applicant, his successors or assigns shall comply with all requirements of the City Engineer 13. Parking Department The applicant shall comply all requirements of the Parking Department. If any metered parking spaces are to be blocked off, the applicant shall notify the Packing Department in writing no less than 48 hours prior to the spaces being blocked. 14. Fire Department All work shall comply with the requirements of the Salem Fire Department. 15. Office of the Building Commissioner All work shall comply with the requirements of the office of the Salem Building Commissioner. 3 16. Utilities Any utility installation shall be reviewed and approved by the City Engineer prior to the issuance of a Building Permit. 17. Maintenance a. Refuse removal, ground maintenance and snow removal shall be the responsibility of the applicant. b. Winter snow in excess of snow storage areas on the site shall be removed off site. c. Maintenance of any landscaping shall be the responsibility of the applicant, his successors or assigns. The applicant, his successors or assigns, shall guarantee all trees and shrubs for a two- (2) year period. 18. As-built Plans As-built plans, stamped by a Registered Professional Engineer, shall be submitted to the Department of Planning and Community Development and Department of Public Works prior to the issuance of the final Certificate of Occupancy. 19. Violations Violations of any condition shall result in revocation of this permit by the Planning Board, unless the violation of such condition is waived by a majority vote of the Planning Board. I hereby certify that a copy of this decision and plans has been filed with the City Clerk and copies are on file with the Planning Board. The Decision shall not take effect until a copy of this decision bearing the certification of the City Clerk that twenty (20) days have elapsed and no appeal has been filed or that if such appeal has been filed, and it has been dismissed or denied, is recorded in the Essex South Registry of Deeds and is indexed under the name of the owner of record is recorded on the owner's Certificate of Title. The owner or applicant, his successors or assigns, shall pay the fee for recording or registering. Walter B Power, III Chairman i 4 i D _ D 0 a � x W p ry Zs o n un � cn m � y n m I+y W n W w E--4z x z LL- List List of Drawings . Architectural P LAN r4eN07 C3OAR 0 APF'ROVEi? A0. 0 Cover Sheet SITE PLAN A1 . 0 Construction Plans m A2. 0 Elevations A3. 0 Sections _ � �L ym CIVIC U) a C. 1 Site Pian0 N UL ownO cc C� 0, E co Structural , o Cn o a S . Bridge Framing Plan � o Owner: Architect: Civil: Structural: Mechanical Electrical, & Plumbing Engineers: L Salem Five Cents Savings Bank Winter Street Architects, Inc. Harnwey Engineering, Inc. - Aberjona Engineering, Inc. Engineered Systems, Inc. 210 Essex Street 209 Essex Street, Suite 300 14 Manning Ave. One Mount Vernon Street One Van De Graaff Drive, Suite 107 ` Salem, MA 09170.. Salem, MA 09170 Leominster, MA 01453 Winchester, MA 01890 Burlington, MA 01803 978-720-5810 978-744-7379 978-840-2964 781-729-6188 781-494-9009 Fax: 978-720-5211 Fax: 978-741-0240 Fax: 781-494-2009 � wsa@wsarchitects.com AsO Glass curtain wall Kawneer 1600 with Low—E, insulated safety glpss 'i . SA GR _ EEN THIR FLOOR ONE SALEM z 210- ES-SEX -STR-EET—� 00 THIRD FLOOR . N m Cn M O n I I o M � � n Edge of soffit w/ cove light above N E-4 o W .. � W O Centerline of steel) framing I V1 N 00 X Edge of roof abo e OD G o °' ►• W w rn E-+ w Z 3 Upper Level Bridge Plan X z ° o 57--10" +/- SPAN ` ` 0- N A1 .0 Scale: 1/4" = 1'-0" 8'-5 3/4" I 49'-4 1/4- Glass /4"Glass curtain wall,1 Kawneer 1600 with Low—E, insulated safety gllass cc — — _ W,J 0-- ONE SALEM GREEN m SECOND FLOOR 210- ES-SEXSTR-EES00 SECOND FLOOR = _ = ■> -- _ i _ _ _ _ _ % ■i C Edge of soffit w/ cove light above Edge of wood trim over ■> W W steel beam, lower I level only. I V• .:3 o U � cc Centerline of steel framing Noun • m 2 Lower Level Bridge Plan � Q) I O � 3 A 1 . Scale: 1/4" = h,-0�� 8'-5 3/4" 149--4 1/4 L Acid t4 I IN G BOA -T.....W ; D Edge of b id e ab ve APPROVED — — — — — — — — — — — — — — — — — — — — — — — — - -- SITE: PLAN ONE SALEM GREEN N I I � o' 210 ESSEX STREE- co I I v v I I � Steel columns cladin rigid insulation and alu obond aluminurm m cladding o 1 Ground Level Plan Recessed Sov�;fl'�t L h s b / A 1 .0 Scale: 1/4" = 1'-0" i i i � I I 1 s s 2 I I A2.0 O 57'-10" +/- SPAN a 8'-5 3/4" 49'-4 1/4" � o r, o A2.0 x o M o CD Standing seam vaulted metal roof _e� = M E-4 �, N Painted steel beam, E-1 exposed on window 00 side. I `� � o W w '' Fq WO Z X Z O Q Lj71 1 N a I N Two—storey aluminum I I curtain—wall system, Kawneer 1600, with Low—E Safety Glass cc _75 ID1 C 0) I I I , C L Sides of bottom deck, soffit, and columns wrapped in 1 1/21' I I I = rigid insulation, 3/4" plywood, and Alucobond metal cladding. •> LL s O o O V vi OO OO O CO O � v � tQ r E O a 3 I I0.Mom PLANNING O,,'RD APPROVED I I I SITE PLAN o 0 N �> East Elevation 0 Scale: 1/4" = 1'-0" v w A2 .0 1 i 2 I A2.0 0 57'-10" +/- SPAN Z Q " I 8'-5 3/4" 49'-4 1/4" E 0 Standing seam vaulted - metal ro f � . 0 3A In x Roof (;;]).fnk TOS Elev: 74.58' — — — — — — — — — — — — — M °i P00 --_ O M - -- -- - --- — -- —- —-- -- I I I N rte, --- ------------- --- O W �, Wo � m n Gwb Soffit with cove g U� N I I I I Standin seam voulte ML I I metal roof n lighting I Standing seam vaulted co o o) metal roof r w w Painted steel beam, °' F w Z exposed on window O Gw Soffit an Painted steel beam, I side. Q Z o = ' exr ansion joint exposed on windowf:1 DIMFl- Painted Exi ting Ceilin side. gypsum board Third Floor I ceilin and cove Slab Elev: 61.08' TT Painted gypsum board ceiling and cove .: i o o 00 Supply air duct, slot diffulsers on both Supply air duct, slot IL4 = - sides. i7diffusers on both 1z I Two—storey aluminum I I sides. JUWV�� I - Cove lighting, Litecontrol Cove 45 curtain—wall system, Gw Soffit anc Cove lighting, Kawneer 1600, with Litecontrol Cove 45 = expansion join ; Sprinkler pipes and Low—E Safety Glass sprinkler heads along1-1 (� Exi ting Ceilin I Sprinkler pipes and insidle of beams M \ nsr' alongSecond Floor L Slab Elev: 48.34' °O Ide of beams I Two-storey au inumo M s'_s' Clear� Y.1 curtain-wall system, Two-storey aluminum JL 1711, Kawneer 1600, with •: . - =:: ' curtain-wall system, *C.4 Low-E Safety Glass >- -- iL Kawneer 1600, with .� 3" 6" Low-E Safety Glass Ca L Outdoor Recessed to 7' 3' Columns furred-out Soffit Lights, Bega (n C Sides of bottom deck, 7„ 3. 1233/560 I 11'L1" �� flush bridge..with edge of �•+ soffit, an columns wrapped in 1 1/2" I I 1t' 1' Sides of bottom deck, soffit, and columns Q) 9 L ri id insulation, /3 4 plywood, I wrapped in 1 1/2„ rad I I I Alucobond metal co rigid insulation, 3/4” 0 0 N M plywood, and cladding. _ I N Alucobond metal Parklnig Level beyond 0) E, 1 = cladding I „ . .� D ADO — .� I Cc v (0 o "M O co co o First Floor CN Slab Elev: 31.15 � U m I I no ai a` co O to 3 210 ES EX STREET I II I APS Basement _ o I I I Is- � 0 �� .� Slab Elev: 21.15' N •� I ,/ 1 Section 2 Section A3.0 Scale: 1/4" = 1'-0" �-oScale: 1/4" = 1'-0" N 3 Section 0 0 U U A3.0 Scale: 1/4" = 1'-0" "' GENERAL NOTES: 1. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES AND o STRUCTURES TAKEN FROM RECORD PLANS AND LIMITED FIELD INSIDE FACE ° , NEOPRENE BOOT CHECK AND ARE APPROXIMATE ONLY. THE ENGINEER DOES NOT OF MANHOLE -----_ GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND o / SUBSURFACE STRUCTURES ARE SHOWN. THE CONTRACTOR SHALL 17 VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES PRIOR TO THE START OF CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ARCHITECT OR ENGINEER IMMEDIATELY. HAND PACKED 2. UPON ENTERING THE SITE, THE CONTRACTOR SHALL BE NON-SHRINK GROUT � RESPONSIBLE FOR ;ALL EROSION CONTROL AND DEWATERING AND STAINLESS STEEL CLAMP SHALL ENACT CONTROL MEASURES TO ENSURE NO SILTATION OF THE STREETS AND THE DRAINAGE SYSTEMS. PIPE 3. CONTRACTOR SHALL MAINTAIN ALL EXISTING AND NEW UTILITIES IN GOOD WORKING ORDER AND SHALL PROTECT THEM FROM FORMED DAMAGE AT ALL TIMES UNTIL THE WORK IS COMPLETED AND OPENING ACCEPTED. 4, REMOVE ALL PAVEMENT WHERE NEW PAVEMENT IS INDICATED, OR REMOVE IF OTHERWISE REQUIRED FOR INSTALLATION OF ANODIZED ALUMINUM \\ NEW CONSTRUCTION, OR STEEL KORBAND o o EXPOSED METAL TO BE 5. SAWCUT THE LIMITS OF EXISTING CONCRETE PAVEMENT AND PROTECTED FROM CORROSION BITUMINOUS PAVEMENT TO BE REMOVED. W/ A BITUMINOUS COATING 6. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH ° THE SALEM SUBDIVISION REGULATIONS AND DEPARTMENT OF PUBLIC WORKS REQUIREMENTS. 7. ONCE CONSTRUCTION IS COMPLETED ALL CATCH BASINS, DRAIN MANHOLES AND DRAIN PIPES SHALL BE CLEANED AND FLUSHED OUT. 8. CONTACT DIG-SAFE 72 HOURS PRIOR TO EXCAVATION, TELEPHONE PIPE CONNECTION DETAIL NO. 1-888-344-7233. (FOR PVC PIPE) NOT TO SCALE LOAM do SEED PAVEMENT EXTERIOR WALL FINISH GRADE DOWNSPOUT BY OTHERS i SEE ARCHITECTURAL DRAWINGS - - BUILDING COMMON FILL OR BACKFILL WITH EXCAVATED - PACK DOWNSPOUT SHOE MATERIAL IF ACCEPTABLE N BY OTHERS WITH NON-SHRINK GROUT TO THE ENGINEER --- W DUCTILE IRON CLEANOUT TEE BRANCH W/ THREADED PLUG -� 12" DIA. 12" DRAIN PIPE - - BIT. CONC. PAVING — PIPE BEDDING MATERIAL FINISH GRADE TO MUDDLE OF PIPE; 6 , BEDDING MATERIAL SHALL ND 6" PVC 1=29.19 . BE HARD, DURA3LE CLEAN 6" DUCTILE IRON ND 6" PVC UNDISTURBED / COARSE SAND ROOF LEADER -1=29.08- , - NATURAL EARTH --------- DRAIN TRENCH SECTION ROOF DRAIN NEW DOWN SPOUT W —_;`� NOT TO SCALE \ \ FLOW n \ �1=28.90 - - - DUCTILE IRON WYE BRANCH M NEW PAVEMENT i 18• GnATE x - \ LLJ PATCH (TYP.) _ X. i J BIT. CONC. TOP COURSE 1" MIN. - APPLY TACK COAT OF RS-1 EMULSION DOWNSPOUT SHOE DETAIL OR MATCH EXIST. THICKNESS, TO ALL VERTICAL FACES OF EXIST. NOT TO SCALE ---- 'HT' \ WHICHEVER IS GREATER PAVEMENT PRIOR TO THE PLACEMENT ! --- / OF NEW BIT. CONIC. PAVEMENT SEAL AFTER PAVING BIT. CONC. TOP COURSE 2" 3 ! - \� WITH TACK COAT AND MIN. OR MATCH EXIST. - SAWCUT EXIST. BIT. PVMT., E ____, ---------- - THICKNESS, WHICHEVER IS 30 95� i --- STCNE DUST CUT TO PASS THROUGH ENTIRE ^ J 1 , �,� GREATER DEPTH OF EXIST. PVMT. z (�."" 3 ci % EnLLA._ I j GAS !�\ i/ TUF .i 1_� ?' = EXIST. BIT. PVMT. EXIST. BIT. PVMT. 1 x - EXIST. GRAVEL ,.;'„ ! � '> Cl��� *;,; r':�`ti.�; .. ,,.r,.,,;'w•�,',�' EXIST. GRAVEL �4y • _i ,d! _ BASE '�;^`' �' t:;` � '. ., ;a' 4!K ' :M'•: BASE �` 17 L-y 12" MIN. COMPACTED CRT - c GRAVEL ; ,,f. 12" LIMITS OF TRENCH 12" Ot,K . YARO , 7 ' =NDRAIN R A,N NOTES: REV. NO. DATE DESCRIPTION 1. ALL INSTALLATION AND MATERIAL SPECIFICATIONS PER MASSACHUSETTS 1 12/29/03 TOPO & ROOF DRAINS HIGHWAY DEPARTMENT STANEDARD SPECIFICATIONS FOR HIGHWAYS AND BRIDGES. 2. ANY PAVEMENT PATCH APPL.IED AT A WIDTH OF 6' OR GREATER IS TO BE PLACED BY MACHINE/BOX SPREADER. BIT. CONC. PAVEMENT PATCH DETAIL NOT TO SCALE SITE PLAN - =- 'x, LEGEND SALEM FIVE CENT SAVINGS BANK EXISTING DESCRIPTION NEW %s 11 Of �y SALEM, MA FRED iso+ c O DMH DRAIN MANHOLE y �jR, �^ ,. SCALE 1"=10' DATE NOV 11, 2003 ❑ CB CATCH BASIN CIV►L »� BIT. CONC. BITUMINOUiS CONCRETE tic.=42 433x6 SPOT GRADE -, �,,,,�1►�°��� HAMWEY ENGINEERING, INC. — D DRAIN — ND PVC POLYVINYL. CHLORIDE PVC 14 MANNING AVENUE —DS DOWN SPO>UT —NQS— �� , � HANDICAP SPACE �—�•-�� J�, LEOMINSTER, MA 01453 ® PAINTED ISLAND (978) 840-2964 PROJECT NO. 03047 FILE NO. FF7 SHEET 1 OF 1 71, ---------- 57'-10" +/- SPAN II p HSS COLUMN ABOVE (IF APPLICABLE) II ,--41"± CENTERLINE OF EXISTING BEAM CENTERLINE OF COLUMN 6'-0" 6'-D" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 3'-2"± TO CENTERLINE OF NEW COLUMN I 6" I 1 I 1 I I , 1 , I Z TYP. M TC - U 4a, I I 7/16 TOP AND BOT. FLANGE "± CENTERLINE OF EXISTING BEAM o CONTINUITY PLATES 1/ REMOVE TO OUTSIDE FACE OF BRICK — TOP AND BOTTOM I 45? WELD TABS I I I I I I I I w PLATE THICKNESS TO BE I W a BEAM FLANGE PLUS 3/8" ( RADIUSED WELD ACCESS HOLE I I I I R_ I I I I I I I Q TOP AND BOTTOM FLANGE W HSS. 1 x12x1/2 S2. LINE 0 GLASS HSS. 12xl2x 1 z W.F. BEAM SEE PLAN O p I I COLUMN I I I ( I COLUMN I o z w W a n CENTERLINE OF BEAMS I I o - - F- U I I I I I I I I I I I F- z N i > O w 1 1 I 1 1 1 1 I I ' O o O o ALIGN COO - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - —D W n`= W30x99 m U m= o zo= HSS. COLUMN1/4 Q ° �'3 (un) ct ~ o 0 SLIP-CRITICAL SHEAR CONNECTION 1 112 x 2 C Go. TYPE B . 111 x O �+ 0 1/2" MIN. THICK SHEAR XISTING R— SLOPE �'- N _ EXISTING M (FLANGE WIDTH + 1' AT 4-SI �E ) I TAB PLATE DESIGNED BY o S2• V2. I o , BACKING BARS TOP AND FABRICATOR BUILDING I I METAL RDO i DECK i i i I Q I BUILDING o BOTTOM FLANGE. REMOVE BACK GOUGE ROOT PASS ], O, C. I "� I "� I "� t I I I I I o O T. 0. C. BOTTOM FLANGE BACKING I z E-+ i BAR PRIOR TO BACK 5/16' AND RE-WELD AFTER x X x x X X x X X I— , , I X p I I I I I I I X U N � BACKER BAR REMOVED EL. 61. 08 ± i i i i i °�° i i i i i m EL. 69 —8 5 AT 4TH F GOUGING AND FILLET WELDING. AND WELD IS INSPECTED. USE E71 T-8 ELETRODES. I I W30x99 I I I I I I I r ' FOR RE-WELDING ROOT PASS E-+ . & FOR THE 5/16" REINFORCING ------ IL --- -- - -- ' WELDS. W00 1_2 W W t\ W Q cc BEAM HSS. COLUMN ORDINARY MOMENT FRAME CONNECTINS Lu v HSS. 12x12x1l2 LINE OF GLASS R— HSS. 12xl2x v " o L-, COLUMN S2. COLUMN 0c) L 1. NO SHOP PRIMER WITHIN 3 INCHES OF FIELD WELDS. REMOVE O O SHOP PRIMER (INCLUDE OVER-SPRAY) IN THE FIELD PRIOR TO WELDING IF NECESSARY. — 2. NO SHOP PRIMER AT "FAYING" SURFACES OF SLIP- CRITICAL ROOT LEVEL EL BRIDGE FRAMING PLAN (E) SHEAR CONNECTIONS. PREPARE "FAYING" SURFACES IN THE FIELD 114"=1 '-0" 7 PRIOR TO ERECTION TO SATISFY CLASS "A" AS DEFINED IN AISC'S "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS". 57'-10" +/- SPAN II 3. THE FABRICATOR SHALL TAKE EXPECTED WELD SHRINKAGE '-0'" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-O" 3,_2"+ II 1"± CENTERLINE OF EXISTING BEAM 6 INTO ACCOUNT WHEN DETAILING THE BEAM LENGTHS IN CONTINUOUS RUNS. TO CENTERLINE OF NEW COLUMN 4. FILLER METAL USED IN THE FULL PENETRATION WELDS SHALL HAVE A I 6 I I I I I I MINIMUM CHARPY V-NOTCH VALUE OF 20 FT-LBS AT 20 DEGREES F. I I "± CENTERLINE OF EXISTING BEAM FOR BUILDINGS WHICH ARE FULLY ENCLOSED AND HEATED DURING THE I I I I I I I I I I TO OUTSIDE FACE OF BRICK WELDING PROCESS AND IN SERVICE AND 20 FT-LBS AT ZERO (0) I 1 I I 1 1 I 1 1 1 DEGREES F. FOR ALL OTHER WELDING SERVICE CONDITIONS. Lij I I ( I I I 5. THE MOMENT CONNECTION WELDS ARE TO BE CONSIDERED "PRE-QUALFIED WELD JOINTS". O W L O W THEREFORE THE STEEL ERECTORS SHALL SUBMIT PRE-QUALIFIED JOINT WELDING W U I I HSS. 1 Nxl2xll2i I S2• I LINE OF GLASS I I I HSS. 12x12x1 PROCEDURES AND JOINT DETAILS AS PER AWS D1.1 CERTIFICATE OF COMPLIANCE O COLUM , COLUMN o 0 FOR ALL THE ELECTRODES TO BE USED, AND WELDING CERTIFICATES FOR ALL THE WELDERS. U I I ( I I I l I I I 6. WELD ACCESS HOLES SHALL COMPLY WITH AWS D1.1 - 1998, FIGURE 5.2. � � '- - - _ — - - - - - -'- - - - - - - _ _ _'— - - -'- - - - - -' - - - - - -' - - - - - -'- - °Q �` W30x 173 - II 4 112" CON ETE SLAB WILn XISTING FL— SLOPE 6x6 W2.9xb 9 W. W.F. (1 OP�VI TOP) Ln N - EXISTING S2. 1 ON 2 x 20 a. COMPOSITE , O I BUILDING I � I I I I I I I I BUDDING T. O. C. I i i r� i GA VANI ZED4 I EEL DECK �,� i i i t 0) z T. O. C. I X I I I I I I I X U , X X X X X X X X X 1= „ EL. 48. 36 ± I � o � I � I � I � I � I � I � I � I o c , � �, A � I � I � I � I � I � I � , � I �, Lo m EL. 58 -4 5 AT 3RD F I q I I I I I I I I X T. 0. C. � LLJW30x 173 o EL. 4 7'-0 5 A T 2ND F Uw Li ' o � w � Oo 0o V. o HSS. 12x12x1/2 LINE OF GLASS L— HSS. 12xl2x �— v COLUMN S2• COLUMN o 0000 < LEVEL - TWO AND THREE - BRIDGE FRAMING PLAN - 1/4"=1 '-0" U) 58'-3" +/- SPAN H 1 x12X1 2 EXISTING t , 1 A„1 1 COLUMN / HSS. 12xl2x Y 1 BUILDING BP- 1 T. 0. C. o COLUMN i i � BP-1 �'7'F'° �. i EL. 31 '-6” AT IST 11R. N O F— dil S2. S2. I a -- - - ------ ----------------- ----------- - --- - - - - - - --- - - -- - -- oal U O I I EXISTING o PARKING 7"± TO FACE OF o EXISTINGI BUILDING EL. 31. 18'+ FOUNDATION WALL I I O m C — —-—-—-—-—-—-—-—-—-—-—-—-—-—-—-—-—- - -—-—-—- - -—-—-—-—- ---—- - - -—-—- —-— z � I I , HSS. 12x12x1/2 HSS. 12xl2x BPL� MN LEVEL - ONE - BRIDGE FOUNDA TION PLAp�U MN (E) 114 =1 —0 7 Simi