Loading...
1 CAROL WAY - ZONING wxO s S?ec�a4 �qu(m I DECISION rIM CI FY OF SALEM. MA CITY OF SALEM CLERK'S OFFICE b » PLANNING BOARD ' 100b JAN 23 P 12: 02 January 20,2006 Decision For The Petition of Nextel Communications of the Mid-Atlantic, Inc. For The Property Located At 1 Carol Way A Public Hearing on this petition was opened on December 15, 2005. The following Planning Board members were present: Walter Power, Chuck Puleo, Gene Collins,Paul Durand,John Moustakis,Pam Lombardini,Christine Sullivan,Tim Kavanagh,and Tim Ready. The Public Healing was continued to January 5,2006 and January 19, 2006. Notice of this meeting was sent to abutters and notice of the hearing was properly published in the Salem Evening News. The petitioner requested a Wireless Communication Facility Special Permit under Section 5-3, Special Permit Uses, of the City of Salem Zoning Ordinance, to allow the installation of twelve (12) antennas in sets of two,located within faux screens in three sectors located on the roof of the building located at 1 Carol Way, Salem,MA.The petitioner is also proposing installation of ancillary equipment within a room in the underground parking structure. The faux screens are to be painted black or dark brown and will match the photo simulations reviewed and approved by the Planning Board at the January 19, 2006 meeting. The Planning Board reviewed the application and plans submitted and found that the petitioner addressed the requirements of this section for the issuance of a Special Permit. On January 19, 2006, the Board closed the Public Hearing and voted by a vote of eight (8) in favor (Power,Puleo, Durand, Moustakis, Lombardini, Sullivan, Kavanagh, Ready), one (1) absent (Collins) from the vote,none opposed, to grant the Wireless Communication Facility Special Permit for the location stated above,in accordance with the application (dated November 22, 2005) and revised site plan dated January 10, 2006, entitled"Nextel—Nextel Communication of the Mid-Atlantic, Inc., Winnin Hill MAMMA", sheets T-1,A-1 — A-5, E-1, E-2 and G-1, and drawn by Vertical Resources Group, 420 Boston Turnpike, suite 408, Shrewsbury,MA 01545, submitted and now part of the file and subject to the following condition: 1. The applicant shall submit to the Planning Board a signed letter by the property owner, Archstone, stating that there are no deed or condominium restrictions prohibiting locating a Wireless Communications Facility on the building at 1 Carol Way. This endorsement shall not take effect until a copy of the decision bearing certification of the City Clerk that twenty(20) days have elapsed and no appeal has been filed or that if such appeal has been filed that it has been dismissed or denied,is recorded in the Essex South Registry of Deeds and is indexed in the grantor index under the name of the owner of record or is recorded and noted on the owner's certificate of title. The fee for recording or registering shall be paid by the owner or applicant. I hereby certify that a copy of this decision is on file with the City Clerk and that a copy of the 120 WASHINGTON STREET, SALEM, MASSACHUSETTS 01970 •TEL: 978.745.9595 FAx: 978.740.0404 ♦ WWW.SALEM.COM decision and plans is on file with the Planning Board. /� p Walter B. Power, III Chairman Cc: Cheryl LaPointe, City Clerk Large Format Box # Doc # � Image # JMIA�GF DATA i I i i i PARKER QUANTUM EXIT 2 LAYERS 5/8" SHEETROCK t EXISTING SIGN AND TAPED AND PAINTED r INSULATION DOOR EMERGENCY ; KEYED CONSTRUCTION NOTES CLOSER LIG T EXISTING CEILING JOISTS !._ 1 000 00i li NEXTEL COMMUNICATIONS O NEW 3'-0" x 7'-0" x 1-3/4" 16 GA. (1 HR.) HOLLOW METAL DOOR O NEW ELECTRICAL EQUIPMENT: REFER TO ELECTRICAL DRAWINGS OF THE MID-ATLANTIC, INC. AND FRAME, REINFORCE HOLLOW METAL UNIT TO RECEIVE HARDWARE. - NEXTEL 200A SERVICE DISCONNECT PROVIDE METAL KNOCK DOWN FRAME. PREPARE FRAME TO RECEIVE - SQUARE 'D' 200A MAIN POWER PANEL 3 3 5/8 16 GA. STRUCTURAL MORTISED AND CONCEALED FINISH HARDWARE. — JOSLYN SURGE ARRESTOR STEEL STUDS Q 16" O.C. MAX. DOOR AND FRAME MANUFACTURER: STEELCRAFT, DIVISION OF AMERICAN 9 CROSBY DRIVE STANDARD CO. OR APPROVED EQUAL. 6 TELEPHONE BACKBOARD: 4 X4 X3 4 TYPE C-D FIRE RETARDANT BEDFORD, MA 01730 FINISH: DOOR AND FRAME SHALL BE FACTORY PRIMED. IN FIELD, O TREATED PLYWOOD. MOUNT WITH TOP AT 7'-6" A.F.F. COVER R-19 FIBERGLASS BATT INSULATION PHONE: (617) 839-6000 TOUCH UP WITH ONE COAT SINCLAIR 15 CHROMEOXIDE METAL PRIMER WITH 1 COAT ALKYD PRIMER, THEN USE FLAT FIRE PAINT, FLAME- FAX: (617) 839-5912 AS REQUIRED. PAINT 2 COATS SINCLAIR 7500 SINTEC ENAMEL, WHITE CRETE NO. 505, SEMI-GLOSS OCEAN N0. 3000; OVERCOAT EGGSHELL 1-2 MILS PER COAT. TINT TO MATCH WALLS. yT 2 INSTALL (2) LAYERS 5/8" HARDWARE: 1-1/2 PAIR BUTTS FBB NRP US26D 4-1/2" X 4-1/2" EA�1 DRYWALL BOTH SIDES OF STANLEY. �7 CLEAN PROPOSED FLOOR AND PREPARE FLOOR AS NESCESARY 1 CLOSER 4040-AL LCN TO RECEIVE NEW RESILIENT FLOOR TILE. NEW TILE SHALL FRAME WALL x ' 1 BEST 82T/83T DEADBOLTS (E2151-181K) BE 12"X12"X1/8" ARMSTRONG IMPERIAL TEXTURE TILE #51836 1 DOOR DROP SEAL 430CR PEMKO COLOR: SHELTER WHITE) PROVIDE 4" ROPPE RUBBER COVE BASE BLOCKING MID SPAN 1 SET DOOR SEAL S88D PEMKO COLOR: BLACK) ON WALLS. L; 1 PUSH PLATE CNO.OS 050 BPLATER(J3pRASS WORKS �8 16 PORT COAXIAL ENTRY BY MICROFLECT #: B1447 1 PULL PLATE NOAODA .050 PLATE (J405) 00 "ARMSTRONG" SBASEG ER NOTE: THE DOOR IS EQUIPPED WITH A LOCKING DEVICE WHICH MAY � WALCOLOR 60 JET ' VERTICAL RESOURCES GRP. BE OPENED FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY BLACK (PN: FS SS-W-40, TYPE 1) SPECIAL KNOWLEDGE. OR APPROVED EQUAL 420 Boston Tpke, suite 408 Shrewsbury, MA 01545 �2 WALL FINISH: DRYWALL: APPLY JOINT TAPE AND JOINT COMPOUND AT JOINTS ` tel. (508) 981 9590 ¢i (BOTH DIRECTIONS). APPLY COMPOUND AT ACCESSORY IFLANGES, 4" RUBBER COVE PENETRATIONS, FASTENERS HEADS AND SURFACE DEFECTS. 7rBASE (TYP) COMPOSITION TILE OR I 7 APPROVED EQUAL fax (508) 519 8939 INSTALL COMPOUND IN 3 COATS, SAND AFTER LAST 2 COATS. DRYWALL TEXTURE: ROLLER SMOOTH. � verticalresources@charter.net Charter.net PAINT: (ALL INTERIOR WALLS OF RADIO FACILITY) PRIMER - 1 COAT SINCLAIR #1770 PIGMENTED PVA SEALER. (OR EQUAL) rAS EVEL FLOOR I�;� SECOND COAT - SINCLAIR #1790 AQUA COATER (OR EQUAL) H 11 REQUIRED ,I SITE NAME: THIRD COAT - SINCLAIR #4000 AQUA SATIN ENAMEL. (OR EQUAL) MDF 1-2 MILS PER COAT. - T WINNIN HILL O3 INTERIOR WALLS TO BE 3 5/8" 16 GA. STRUCTURAL STEEL STUDS ® 16" Q.C. MAX. x EXISTING SLAB-/ U4 RADIO EQUIPMENT (SHOWN FOR COORDINATION ONLY): INSTALLED BY RADIO EQUIPMENT VENDOR. 22'-0" _ ,; SITE NUMBER: INSIDE DIMENSION t=; '� 11V1l12®CJ C�.Cl TYPICAL WALL } EQUIPMENT ROOM SECTION CROSS SECTIOM 27 SCALE: 1/2"=1-0' A 4 SCALE: 1/2"=1-0' A–4 SUBMITTALS t---------------------- ---------------------- ! ! + I III i l l i ! I li T`I i T i I A 10/6/05 FOR REVIEW l ! ! I ! PROFESSIOPNAL STAMP I RECTIFIER J-IBOX WITH FOLLOWING i j 150W QUARTZ i { 1" C. 8 10 & (4)-#10 I ®����a®� 1. P-2,4,6,8,10,12,14,16 , O # EXTERIOR LIGHT I GRD, LEAVE ENOUGH SLACK TO REACH FLOOR ! WITH MOTION i i I i v DETECTOR f 1 } �����L 2. P-1,3,5,7,9,11,13,15 1„ C.,,(8)-#10 & (4)-#10 + t ! I GRD, LEAVE ENOUGH SLAICK TO REACH FLOOR ! i ! NEW WAVEGUIDE I ! ®o JAMEB P m I + ! I 8 QUANTUM EXIT SIGN 1 + i ` y r KE 40 ENTRY PORT W/ EMERGENCY LIGH ! 0 No.2CC�8 NEW CABLE TRAYS TO BE PLACED 4.5” BELOW CEILING ( 1 ! 3 r ' � NEW WALLS TO BE I + I i I + ! � ► r�.r'. � � , ' CONSTRUCTED PER 2/A4 6 Wall i46 i 5'-0' 5'-0 2-0 " 2'-0" 3'-0" 2'-0" 3'—T' --2e2'-0" ; I - � DRAWN BY: G.A.M. CN ' I I o + o W CHECKED BY: M.N. 4 ! F ' 4 --- ------- ------ ( SITE ADDRESS: o i o ' I 5 + I � ------ ONE CAROL WAILIY SALEM , MA 01970 APPLETON APPLETON I, $` PWERLITE POWERLITE- 6'-0" GENERATOR 6 O GENERATOR i 11'-0" RECEPTICLE 11'-O" RECEPTICLE SHEET TITLE: 16'-0" 16'-0„ i DETAILS II CEILING PLAN 3 LIGHTING PLAN 4 �: SHEET NUMBER: SCALE. 1/4"=1-0' A_4 SCALE: 3/8"=1-0' A-4 A - 4 I E - ,- - KEYED CONSTRUCTION NOTES ie 'I GFI RECEPTACLE IN ' 1O HUBBELL - CF5362GY - 20A DUPLEX RECEPTACLE WITH GFI 9O CARRIER - #38HDC-060 - COMPRESSOR CONDENSER UNIT FOR AHU-1 WEATHERPROOF BOX NEXTEL COMMUNICATIONS PROTECTION SPECIFICATION GRADE IN WEATHER (ACU) AND AHU-2. COPPER COIL WITH ALUMINUM FANS, PROOF ENCLOSURE EXTERNAL SERVICE, THERMAL COMPRESSOR UNIT OF THE MID-ATLANTIC, INC. PROVIDE LT32 LOW AMBIENT KIT, BALL BEARING WEATHERPROOF SERVICE kq DISCONNECT SWITCH AT EACH O HUBBELL - 5362 - 20A DUPLEX RECEPTACLE, SPECIFICATION GRADE FAN MOTOR, WINTER START CONTROL, EVAPORATOR INSULATE SUCTION LINE W/ 9 CROSBY DRIVE WHITE, MOUNT 18" AFF FREEZE THERMOSTAT, CRANKCASE HEATER, TXV KIT CONDENSER UNIT ELECTRICAL CONDUIT, TYP INSULATION AND PAINT W/ "UV" BEDFORD, MA 01730 REFRIGERANT FILTER. SYSTEM SHALL OPERATE INHIBITOR PAINT OR EQUAL ALARM JUNCTION BOX: 6"x6" METAL ENCLOSURE TILL 07. REFER TO CARRIER LONG LINE MOUNT UNIT TO SLEEPERS SEE 3/A5 PHONE: (617) 839-6000 SHALL BE PROVIDED AND INSTALLED BY APPLICATION GUIDELINE FOR TUBING SIZES OVER ACCORDING TO MANUFACTURER'S it FAX: (617) 839-5912 CONTRACTOR. (2 #22 CU) 1/2" C FROM J-BOX 50 FT. PROVIDE THE FOLLOWING ACCESSORIES: REQUIREMENTS. MAINTAIN77 ABOVE CONTROLLER TO EACH OF THE FOLLOWING -COMPRESSOR START ASSIST-CAPACITOR/RELAY TYP SUFFICIENT SPACE BETWEEN +' ITEMS UNO: -CRANK CASE HEATER UNITS TO ALLOW FOR PROPER -SURGE ARRESTOR ALARM CONTACTS -CYCLE PROTECTOR VENTILATION. -MAGNETIC DOOR ALARM -LIQUID SOLENOID VALVE - - -HIGH TEMPERATURE THERMOSTAT -LOW AMBIENT CONTROLLER -LOW TEMPERATURE THERMOSTAT -WINTER START CONTROL -SMOKE DETECTOR -MOTOR MASTER CONTROL CYCLE PROTECTOR -LOW PRESSURE SWITCH O SONITROL - 29A - TWO PIECE MAGNETIC DOOR ALARM. RUN WIRE TO -HIGH PRESSURE SWITCH ALARM CABINET. 10 - ` �� , OPTIONAL VIBRATION ��0�0�� u ISOLATOR, TYP (_ ' } VERTICAL RESOURCES GRP. O COMFORT FB4ANBO6005 - INDOOR AIR HANDLING UNIT 2000 CFM ® .125 O DAYTON - 2E 206 - HIGH & LOW TEMP ALARMS: MOUNT ON WALL, RUN (AHU) ESP, NOMINAL 5 TON COOLING CAPACITY 60,000 iJll ! P.T. 4x4 SLEEPERS 5 420 Boston Tpke, suite 408 SIGNAL WIRE FROM EACH DEVICE TO ALARM BTUH 10.4 SEERAT 95-F AT 80'FDB/67'WB PROVIDE _ Shrewsbury, MA 01545 CABINET. MOUNT HIGH TEMP SENSOR. 5KW ELECTRIC HEAT ELEMENT. MOUNT VERTICAL OPTIONAL ROOF PAD. ; I- tel, ry98 OAS SHOWN PROVIDE VIBRATION ISOLATION SUP- ADHERE TO SLEEPERS ONLY. (508) 1 9590 6 HONEYWELL - T874A - THERMOSTAT HVAC CONTROL SINGLE STAGE PORTS UL LISTED 240V, 10, 60HZ, PROVIDE fax 508 519 8939 COOLING/HEATING THERMOSTAT FOR USE RELAY SHUTDOWN PACK FOR CONNECTION TO REFRIGERANT PIPING. INSTALL IN \ �� ������� \ WITH AHU-1,-2. SYSTEM SHALL BE CAPABLE SMOKE DETECTOR. HEAT STRIP INCLUDED. ACCORDANCE WITH T+ verticalresources@charter.net 'S RECOMMENDATION. F OF AUTOMATIC SWITCH OVER FROM COOLING MANUFACTURERINSTALL LIQUID LINE MOISTURE /HEATING. SURFACE MOUNT ON WALL. 11 TITUS - 300RS - SUPPLY GRILLE, STEEL CONSTRUCTION WITH DOUBLE INSTALL FILTER DRIER. INSULATE DEFLECTION PATTERN AND 3/4 BAR SPACING, 10 x10 SUCTION LINE AND PAINT WITH "UV" INDICATOR SIGHT GLASS I: O ESL - 320CX - SMOKE DETECTOR WITH AUXILIARY CONTACTS 120V - - INHIBITOR PAINT OR EQUAL. SITE NAME: POWER CONNECTION. AUXILIARY CONTACTS SHALL 12 TITUS 350ZRL RETURN GRILLE, STEEL CONSTRUCTION WITH 0' BE WIRED TO ALARM CABINET. DEFLECTION AND 3/4" BAR SPACING, 12"x16" CONDENSER UNIT DETAILS 2 WAIN HILL r O8 APPLETON - AJA2003420ORS - APPLETON POWERLITE 200AM GENERATOR 13 LITTLE GIANT - VCM20UL - CONDENSE PUMP 25 GPH 15' TDH. EQUIPPED SCALE: N.T.S. A-5 RECEPTACLE, 3 WIRE, 3 PIN, WALL MOUNTED WITH TANK AND OVERFLOW ALARM SWITCH 120V. OPPOSITE TRANSFER SWITCH CONDENSER UNIT INSTALLATION ('1 SITE NUMBER: SCALE: N.T.S. A-5 r n MA2088A t i SUBMITTALS i I NOTES - FIRE ALARM CONNECTION FIRE ALARM SYSTEM 1. CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIAL AND DEVICE MAKE MODEL ' LABOR TO TIE THE NEXTEL FACILITY INTO THE BUILDINGS EXISTING FIRE ALARM MONITORING SYSTEM AS REQUIRED BY LOCAL CODE AND THE MUNICIPALITY INCLUDING IF REQUIRED LED LIGHTS, HIGH EXISTING FIRE ALARM i f TEMPERATURE SPRINKLER HEADS, AND ADDRESSABLE TIE—IN TO CONTROL PANEL ! { I THE HOUSE PANEL. -- r• + i SMOKE DETECTOR HONEYWELL } i 2. COORDINATE ALARM TIE—IN AND TESTING WITH THE BUILDINGS FACILITY MANAGER OR OWNER. THE BUILDING OWNER MAY ALSO HEAT DETECTOR HONEYWELL -- „ d If Ji ri 1 I REQUIRE THE CONTRACTOR TO USE THE EXISTING ALARM COMPANY *PULL STATION HONEYWELL -- " 1 ( i FAMILIAR WITH THE SYSTEM. ! ' *HORN/STROBE HONEYWELL -- t A 10/6/05 FOR REVIEW I *IF APPICABLE VENDOR: PROFESSIONAL STAMP I II t � , ?' bXXAAA.4e I ' I ►'� P�-��OF 150W QUARTZ EXTERIOR LIGHT „ JAMES!P. N�` WITH MOTION , i , ; ALARM SCHEDULE �!q�,� DETECTOR ! ! 4 I STROKE � DETECTe, QUANTUM EXIT SIGN ! ! NOTES: .J No.200,68 2 I 1. ALARM CONDUCTORS SHALL BE RUN IN A W/ EMERGENCY LIG I I I I DOOR SEPERATE CONDUIT FROM POWER CONDUCTORS. j ! ALARM 2. ALARM SEALTI HONDUCTORS TO BE IT WITH A INTRA HT CONNECTOR. ►e ►V'fA FLOOR MOUNTED AIR 7 7 I SEALTIGHT CONDUIT TO BE LOCATED ABOVE THE I O1p HANDLER UNITS C/W ! ' ! HIGH SITE CONTROLLER. CONDUCTORS SHALL BE METAL DRIP PANS I I I I TERMINATED BY OTHERS. � 1,111 3 TEMP 3. ALARM CONTACTS TO BE NORMALLY CLOSED. ,' OPENING OF CONTACTS INDICATES ALARM CONDITION IOt pig" L0V'A 1I 4. ALARM CONTACTS ARE SHOWN IN NON-ALARM MODE. 5 TENAP 5. • - INDICATES NOT IN CONTRACT. AC POWER FAILLURE DRAWN BY: 2- 3'-0" --7'2'-0" 3'- 2'-0" 6 G.A.M. CIRCUIT— TERMINAL ALARM DESIGNATION -------__----- ---__._..__--------- --- --- UMBERS I SURGE 1-2 DOOR ALARM - -------, 3-4 HIGH TEMP CHECKED BY: M.N. 5-6 LOW TEMP KcV I � 2 7-8 JAC POWER FAILLURE K ! ! SMOKE DETEDTOR FOR 9-10 AC SURGE FAILLURE SITE ADDRESS: - --- iIF !I ----oo-----II I oQ !r I HVASHUTDOWN TB 11-12 SMOKE DETECTOR A •-1, I ( 13-14 HVAC FAILLURE O N E CAROL WAYHVAC FAILLURE 15-16 SPARE ——— ------ - -1 -- ------- L #1 & #2 F17-18 SPARE 3/4" CONDENSATE ! a i ! I a A DRAIN PIPE To__,--- I i I EXTERIOR 1 PER ! AIR HANDLER SPARE 01970 . APPLETON I % 1 2 2 TO POWERLITE g SPARE SHEET TITLE: 6'-0° GENERAR O 7 RECEPTICLE I 16'-0" EXTERIOR MOUNTED COPPER REFRIGERANT PIPING DETAILS I SUCTION & 1-3/ 1-1/8" 8" LIQUID TB ' CONDENSER UNITS O TO EACH OF THE CONDENSER UNITS 1 2 3 4 5 6 7 8 9 1011 12 13 14 1516 17 18 CEILING PLAN 3 SHEET NUMBER: SCALE: 1/4"=1-0' �-5 A - 5 3 _ I KEYED ELECTRICAL EQUIPMENT LEGEND & SCHEDULE ' ELECTRICAL AND TELEPHONE ___________ _________________________ ______________ ___________ _______________________ _____ __ Y 1 — — METER & SOCKET TO MEET ELECTRIC COMPANY'S GENERAL NOTES ''� ` - - - - ` `. NEXTEL COMMUNICATIONS OF THE MID-ATLANTIC MANUAL NON—FUS INC. REQUIREMENTS. TRANSFER SWITCH,IBLE 3-#3/0, 1-#4 GROUND 2 SQUARE D - 50S3H - STANDARD VENTILATED DRY TYPE 1 . FOLLOWING COMPLETION OF WORK, PROVIDE OWNER WITH AS—BUILT 1 0, 2 POLE SN IN 2"� coNDUIT 9 CROSBY DRIVE O 50kVA STEPDOWN TRANSFORMER DRAWINGS SHOWING TELEPHONE AND ELECTRIC LOCATIONS. BEDFORD, MA 01730 2. WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE. 3-#3/0, 1—#4 PHONE: (617) 839-6000 �3 SQUARE D -DTU224NRB- SQUARE D MANUAL TRANSFER SWITCH GROUIND IN 2"0 FAX: (617) 839-5912 CONDUIT 200A, 42 SPACE, 120/240 3. ROUTE TELCO AND POWER CONDUITS TIGHT TO CEILING JOISTS. VAC 10, so Hz LOAD CENTER �4 SQUARE D - OR EQUAL - 10 120/240 VAC MAIN DISCONNECT SWITCH EQUIPMENT ROOM TO BE PENETRATED WITH LB ABOVE TELCO AND W/ 200 AMP QO SERIES ELECTRICAL BOARD SEE 1/A4 FOR DETAILS. --�— MAIN BREAKER, NEMA 1 t SURFACE MOUNT 5 SQUARE D - #NQOD - 225A SQUARE D TYPE NQOD NEMA1 SURFACE N 4. INSTALL AND WIRE 200 AMP, 120/240 V, 3W, SINGLE PHASE SERVICE. ^` MOUNTED 225, 1PH, 3W, 40 1-P POSITIONS / USE QOB CIRCUIT BREAKERS. FOR HVAC USE WIRE TO DISCONNECT. O O SURGE HACR CIRCUIT BREAKERS SUPPRESSOR 5. ALL EXISTING LINES ON SITE TO BE LOCATED PRIOR TO ! VERTICAL RESOURCES GRP. �6 JOSLYN - #1455-85 - SURGE ARRESTOR: PROVIDE AUXILIARY CONSTRUCTION. EXTERIOR ALARM CONTACTS, INSTALL PER MFGRCEPTACLE6. SEAL ALL SERVICE ENTRANCES INTO EQUIPMENT ROOM FOLLOWING �Tv ss FORE EAUXILIARY 3 '+ 420 Boston Tpke, suite 408 REQUIREMENTS, 120/240V 1 PHASE 3 WIRE PLUS GROUND INSTALLATION. GENERATOR Shrewsbury, MA 01545 30A-2P CB IN tel. (508) 981 9590 PANEL 4-#10 IN 3/4"0 RGS fax508 �7 APPLETON - AJA20034200RS - APPLETON POWERLITE 200AM GENERATOR CONDUIT (KEEP AS fax ( ) 519 8939 RECEPTACLE, 3 WIRE, 3 PIN, WALL MOUNTED --V3-#3/0, 1-#4 GROUND SHORT AS POSSIBLE) j VerticalresourcCS@Chafter.net OPPOSITE TRANSFER SWITCH IN 2"0 PVC CONDUIT ff SITE NAME: ELECTRICAL SYSTEM NEXTEL EQUIPMENT ROOM ------------------------------------------------------------ ------------------------------------ WINNIN HILL MAIN DISTRIBUTION NEXTEL 50 kVA STEP DOWN TRANSFORMER WITH NEW VOLTAGE 480 VOLTAGE 120/240 DISCONNECT SWITCH. ; PHASE 3 PHASE 1 ONE LINE DIAGRAM 2 SITE NUMBER: AMPS 800 AMPS 200 SCALE: W.T.S. E-1 z: MA208 8A ELECTRICAL SYSTEM SCHEDULE j SCALE: N.T.S. E-1 SUBMITTALS y: ---------------------- --------------------- x 1 22,000 A.I.C.NEMA 1 NOTES: NEXTEL PANEL SCHEDULE I I 1 "RS" SUFFIX SPECIFIES "REVERSE SERVICE". THIS MUST BE SPECIFIED FOR BOTH BOX RECEPTACLE AND MATING PLUG FOR GENERATOR CORD SET. CKT DESCRIPTION AMP AMP DESCRIPTION C� R x 2. IF THE APPROPRIATE MOUNTING BOX AND ANGLE I rir APPLETON AJA20034-RS G 2 . I ADAPTER ARE ALREADY INSTALLED, THE BOX RECEPTACLE 1 STYLE 2 MAY BE ORDERED SEPARATELY AND INSTALLED IN THE RECTIFIER #1 30 30 RECTIFIER #2 (PART NUMBER FOR FIELD. BOX RECEPTACLE PART NUMBER: APPLETON 3 4 ! j ! ! COMPLETE O oI ADR20034-RS STYLE 2. A 10/6/05 FOR REVIEW ASSEMBLY-INCLUDES 5 6 I 3 3. WIRING FOR SINGLE-PHASE 120/240 VOLT SERVICE IS 7 RECTIFIER 3 30 30 RECTIFIER 4 C ! I I AJA-SERIES BOX AND # # g PROFESSIONAL STAMP ANGLE ADAPTER) O AS FOLLOWS. PIN G - GROUND PIN (TOP OF CONNECTOR, NEAR 9 RECTIFIER #5 30 30 RECTIFIER #6 10 G - 11 12 INDEX PIN) - GREEN CONDUCTOR PIN 1 - RED CONDUCTOR, HOT LEG Sid*i�a�d� PIN 2 - BLACK CONDUCTOR, HOT LEG 15 RECTIFIER #7 30 30 RECTIFIER #8 14 I I i GENERATOR RECEPTACLE, VIEWED FROM PIN 3 - WHITE CONDUCTOR, NEUTRAL 16 I OUTSIDE OF SHELTER LOOKING INTO �AtiaEs P ° f I i ( 4. CELL SITE RECEPTACLE MOUNTING BOX AND ANGLE 17 t8 ®i STROKE m ° SLEEVE CONTACTS THAT (CORD SET WILL ADAPTER IS INTERCHANGEABLE WITH CROUSE-HINDS RECTIFIER #9 (FUTURE) 30 30 RECTIFIER #10 (FUTURE) 0 _+ I I EXISTING MATE WITH). CABLES EXI1r FROM REAR PARTS LISTED. 19 20 ,' 0 No.2006e ELECTRICAL & AND CONNECT TO TRANSFER SWITCH. A '9F T p lie ` ! I TELCO ROOM 21 APPLETON: CROUSE-HINDS HVAC UNIT #1 60 60 HVAC UNIT #2 22 • ;S �N AJA520: AJ58 23 HACR TYPE HACR TYPE °► - AJA620: AJ68 24 AJA720: AJ78 25 HVAC UNIT #3 !(SPARE) 26 HACR TYPE - 100 SURGE ARRESTOR GENERATOR PLUG DETAIL 3 27 28 c� 29 RECEPTACLE 1 - INTERIOR 20 20 LIGHTING 30 SCALE: N.T.S. E-1 t - 5'-0" 2'-0" 3'-0" 2'-0" 3'-0" 2'- " 31 RECEPTACLE 2 - TELCO 20 20 RELAY (SMOKE DETECTORS) 32 DRAWN BY:-------------- G.A.M. 33 RECEPTACLE 3 - GFI 20 20 HVAC CONTROLLER 34 I ------ , --------� ---------- 35 RECEPTACLE 4 20 20 SPARE - 36 CHECKED BY: M.N. I I ! K to 37 SPACE - - SPACE 38 --- 1 -- -- SPRINKLER ROOM 39 40 SITE ADDRESS: (WATER MAIN) ONE CAROL WAY I SALEM , MA 01970 .,f TELEPHONE SERVICE ELEVATION 5 6'-0., 3 SCALE: NTS E-171 SHEET TITLE: Ir 16'-0" 7 7 ELECTRICAL DETAILS I CEILING PLAN 4 SHEET NUMBER: SCALE: 3/8"=1-0' E-1 E - 1 -_-- _..-._. -,.-.._•--____..-.. � '-.--•-+.---.+ ..-..-..--.-.-mow._+,. _ ..e �.w , ! MOUNT UNISTRUT TO BRICK WALL USING 1/4 FILL SPACE WITH (I PIPE (SIZE VARIES) HILTI KWIK-BOLTS DOW CORNING 790 PROPOSED 18" LONG NEXTEL COMMUNICATIONS STEEL STUD OR APPROVED EQUAL "P1000" UNISTRUT '' GROUT ALL VOIDS I CHANNEL OF THE MID-ATLANTIC, INC. RUNNER AT AROUND SLEEVE 9 CROSBY ©RIVE GROUT ALL VOIDS , TOP be BOT � ' AROUND SLEEVE --------------- --------------- ------ BEDFORD, MA 01730 d PIPE SLEEVE FIRE SAM ON , __ -_-_-_-_-_-_ PHONE: (617) 839-6000 �r IMPALING CUPS0 ' o a I FAX: (617) 839-5912 I ' c _ POWER CONDUIT--�� PIPE (SIZE VARIES) r ° ( --------------- -------------- - ' . .• •,• °• l2ps PROPOSED UNISTRUT A PIPE OR FILL SPACE WITH u� a °° " CENTER 4 1/2" O.D. PIPE C 18 CONDUIT DOW CORNING TO PART# P1121 PIPE OR CONDUIT I SEE MECH 790 OR EQUAL CENTER 4c", OR ELEC DWG r fi EXISTING HEATING PLANT BASEMENT CEILING CMU GROUND WIRE CONDUIT I U.L. APPROVED - --------- ------ ?:i VERTICAL RESOURCES GRP. - ---- CONT SMOKE STOPPING PIPE SLEEVE PROP. CONDUIT COAX ------ ------ TELCO CONDUIT SEALANT EACH SIDE NOTE: 1/2" TYP' AND SMALLER CONDUITS 420 Boston Tpke, suite 408 TO PASS THROUGH PIPE ANCHORAGE IS REQUIRED PROPOSED UNISTRUT Shrewsbury, MA 01545 NEARBY TO PREVENT PIPE NOTES:1. CARE TO BE TAKEN DURING CORING TO AVOID EXISTING 2 3/8 O.D. PIPE CLAM tel. (508) 981 9590 MOVEMENT through PENETRATION CONDUITS AND EQUIPMENT. PART# P1117 I fax (508) 519 8939 2. CORING REQUIRED FOR CONDUIT. TVP— VIEW SIDE—VIEW verticalresources@charter.net THROUGH FIRE RATED GYP BD WALL CMU WALL (CONC. WALL SIMILAR) CORING DETAIL r2 b" SITE NAME: SCALE: N.T.S. E_2 CONDUIT WALLCEILING ATTACHMENT DETAIL 3 SECTION — PIPE PENETRATIONS 1 SCALE: N.T.S. E_2 VV INNI HILL SCALE: N.T.S. E-2 Am SITE NUMBER: PROPOSED UNISTRUT POWER CONDUIT MA2088A 4 1 2" O.D. PIPE CLAMP ' ATTAC 0 H T / EXT'G ROUTE POWER AND TELCO CONDUITS AS CLOSE AS PART# P1121 ,--CEILING JOISTS. POSSIBLE TO CEILING JOISTS SEE 3/E2 FOR DETAILS CONDUIT SUPPORTS SHALL BE o LOCATED WITHIN 1 FT. OF ENDS OF UNISTRUT CHANNEL --- - - TRAY, 1 FT. WITHIN TURN IN�� TRAY, PIOOO ( PROPOSED 18 LONG AND THE BALANCE AT 4'-0" O.C. MAX. MIN. LENGTH 6-(TYP.) (TYP.)P1010 ti SUBMITTALS "P1000" UNISTRUT --- --- x: ,t NEXTEL CHANNEL MICROFLECT "131657" - EQUIPMENT RUBBER MAT LB TYP. ROOM THREADED ROD ELEWATION (n'P') f, FLAT PLATE UNISTRUT P1064 (TYP.) ' fOX {. CONDUIT SLEEPER ATTACHMENT DETAIL ______________ SCALE: N.T.S. E-2 ELEVATION SECTION COAX/ELE,CT/TELCO DETAILSUP 0 TP R (_6 ;.. A 10/6/05 FOR REVIEW SCALE: N.T.S. SCALE: N.T.S. E-2 `� ANTENNA WITH 7/16 PROFESSIONAL STAMP • DIN CONNECTOR ®�pAAA44® F WHITE PLASTIC SIGN JAMES P. INTERIOR COLOR "NEXTEL" YELLOW i o STROKE y 1.8" v No.?.0063 7/16 DIN MALE ALL TEXT TO BE BLACK IN COLOR ;, ,p �4a° A s „ J 7/16 DIN MALE ELECTRICAL & TELCO SERVICE*. 4 0 1 2" JUMPER CABLE 6 -- -- NB(rEL SCALE: N.T.S. E-2 NEXTEL SHELTER/ROOM FT MAXIMUM NEW ENGLAN 7/16 DIN FEMALE o WIRELESS COMMUNICATIONS FACILITY DRAWN BY: G.A .M. 18 COAX CABLE o 00 CHECKED BY: M•.N. MAX (SEE NOTE 2) 4 t " IN CASE OF EMERGENCY � SITE ADDRESS: Y SYMBOL SIZE, IN. MATERIAL APPROX. RUN LENGTH, FT* BY COAX BEDETERMINED ESIZE ED a CALL (800) 867 — 9980 POWER (SECONDARY) P 4"o PVC / RGC 30' 0 N E CAROL WA Y DIN FEMALE 0'S TELCO T 2'o EMT 50' BOOTED, WEATHER—SEALED o SITE #: M A 2 0 8 8 Aj SALEM , MA SURGE SUPPRESSOR WALL FEED 0 � 01970 GROUND G 1"o EMT 50' DEVICE EMERGENCY EG 2"o PVC / RGC 30' DIN MALE DIN FEMALE 7/32"0 GENERATOR (SILVER PLATED) } HOLE, U� (TYP.x4) SHEET TITLE: * LENGTHS ARE ESTIMATES; CONTRACTOR SHALL VERIFY IN FIELD. � 3.8' � ELECTRICAL 4.0' TYPICAL ANTENNA DIAGRAM r8 NOTE DETAILS II CONDUIT SCHEDULE SCALE: N.T.S. E-2 1 ON EXTERIOR OR OF E TINSTALL EQUIPMENT E SIGNAGE Q OM DOOR SCALE: N.T.S. E-2 FACILITY SIGN 9 SHEET NUMBER: SCALE: N.T.S. E-2 l - 2 -- - i #6 AWG GREEN, STRANDED f GROUNDING LEGEND ! GROUNDING GENERAL NOTES GROUND, TYP CONNECT TELCO 2 AWG GROUNDt' TYPICAL DIRECTIONAL SPLICE GROUND BAR TO EWIRE FROM XTERNAL GROUND BAR TO ----- GROUND COPPER WIRE, SIZE AS NOTED 1. GRIND OFF GALVANIZING IN AFFECTED AREA. EXOTHERMICALLY WELD #2 W/ BURNDY CRIMP IGR W/ #2 GREEN BUILDING WATER MAIN . u 0+ 5/8"x10' COPPER CLAD STEEL GROUND ROD --'-^ - - ---- CONDUCTOR AT 6 ABOVE GRADE OR FOUNDATION WHICHEVER IS HIGHER. --A-- EXOTHERMIC (CADWELD) CONNECTION j''{� ! COLD-GALV AFTER. EXOTHERMICALLY WELD OTHER END TO GROUND RING. GROUND PANEL BOARD SURGE ARRESTOR NEXTEL COMMUNICATIONS -', MANUAL TRANSFER SWITCH, ETC. TO IGR W/ j OF THE MID-ATLANTIC, INC. ;, 2. INSTALL GROUNDING KITS AT ANTENNA CENTERLINE, AND STACK EXIT POINTS. #6 GREEN GROUND ROD INSPECTION WELL :` EXTERNAL GROUND BAR KIT ® GROUND COAX LINES. EXOTHERMICALLY WELD #2 DOWN CONDUCTOR TO PLATES,MECHANICAL CONNECTION OUTSIDE EQUIPMENT 9 CROSBY DRIVE In ' RUN DOWN STACK, AND TIE INTO GROUNDING SYSTEM. GROUND MOUNTED ROOM. � r r DOOR AND WALL FOR(SHOWN CLN AWAY FROM BEDFORD, MA 01730 3. ALL GROUNDING WORK SHALL COMPLY WITH NEXTEL CONSTRUCTION CONTRACT FRAME W/ PHONE: (617) 839-6000 ' ! AND MOTOROLA (R-56) STANDARDS. FOLLOWING COMPLETION OF WORK, GROUND #6 GREEN I FAX: (617) 839-5912 ( 1 '; SYSTEM MUST BE TESTED AND SHALL HAVE A RESISTANCE OF 5 OHMS OR LESS `'`' #2 AWG GROUND CONDUCTOR x Ir SUBMIT AN INDEPENDENT "FALL POTENTIAL" TESTING REPORT. FROM EXTERIOR GROUND BAR L L TO GROUND J-BOX ! r 4. ALL GROUNDING CONDUCTORS ON EXTERIOR WALL OF SHELTER SHALL BEt '`} I INSTALLED IN 3/4" SCH 40 PVC CONDUIT TO 12" BELOW GRADE. ATTACH PVC r. INSTALL GROUNDING KITS AT ANTENNA "C WITH GALVANIZED CLAMPS. MASTER GROUND BARrrr•:,:. AT ENTRY PORT FOR � CENTERLINE. RUN CONDUCTOR DOWN i ! TRASH CHASE, SECURED TO COAX ± ' COAX GROUNDING 5. CONTRACTOR SHALL HAND-DIG IN AREAS AROUND EXISTING UTILITIES. MOUNTING BRACKET. TIE INTO GROUNDING ! # TRAY SECTIONS GROUND METAL LOUVERS, ! . , 2 AWG 0 BOND CABLE SYSTEM. GROUND COAX LINES. 6. NOTIFY CONSTRUCTION ENGINEER IF THERE ARE ANY DIFFICULTIES INSTALLING GREEN, CONDUITS, ETC. GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. STRANDED VERTICAL RESOURCES GRP. TIE EXTERIOR TIE INTERIOR MAIN INTERNAL is GROUND BAR INT I ' ! ROUND BAR INTO EXISTING GROUND RING ( . 420 Boston Tpke, suite 408 ROOM GROUND RING I ' i ROOM GROUND ELECTRICAL & (IGR) GROUND TELCO ROOM Shrewsbury, MA 01545 DOOR . i i GROUND tel. (508 981 9590 HVAC UNITS TO IGR ° fax 508 519 8939 ff : GROUND CONDENSATE PUMPS I; -11--------------� r-------- _ ----- -- - - -� TO IGR verticalresources@charter.net r EQUIPMENT CABINETS 3' SITE NAME: ? NOT FOR J �� NOT SHO _ CLARITY WIN IN HILL Q N i Z ; �c EQUIPMENT W z I I I I GROUNDING f; 1 COAX BY OTHERS ' -- a 1 a-- ' SPRINKLER i o I C o i r o t ROOM #2 GREEN STRANDED SITE NUMBER: COPPER TO EXTERIOR COAX GROUND KIT • =�:', � �� a I � I (WATER MAIN) i ! ' GROUND BAR AT OUTSIDE -- t - - 1 2 AWG TNN COPPER o , j o OF EQUIPMENT ROOM # ---- =- }i-------\- N -------- =- �----- -- - - CLAD SOLID CADWELD EQUIPMENT I MA2088 A --------------------- ----- FROM ANTENNA GROUND NEXTEL ROOM TYP. GROUNDNG 7 BAR TO BALLAST MOUNT SCALE: N.T.S. G_ 5 Az I,X' GROUND CONDENSER #2/0 AWG GREEN INSULATED MECHANICAL CONNECTION ANTENNA NOTE "UNITS GROUND CONDUCTOR TO WATE TO GROUND BAR GROUND BAR 2 NOTE 2 NOTE 2 NOTE 2 SUBMITTALS ,; MAIN IN BOILER ROOM ANTENNA COAX ANTENNA COAX ANTENNA COAX 2—GPS COAX CABLE TRAY SECTION BOT. GND KIT BOT. GND KIT BOT. GND KIT GND KIT CABLE CABLE CABLE CABLE 2 #2 GREEN STRANDED COPPER TO EXTERIOR GROUND BAR AT OUTSIDE 90' 220' 330' #6 AWG OF EQUIPMENT ROOM ANTENNA ANTENNA ANTENNJA NOTE 1 NOTE 1 NOTE 1 DISCON. ROOM SITE COMPOUND GROUNDING r—SEE CABLE ANTENNA COAX ANTENNA COAX ANTENNA, COAX EQU. SWITCH HALO SCALE: N.T.S. TRAY SECTION TOP GND KIT TOP GND KIT TOP GNDI KIT r CABLE CABLE CABLE: 2 BCW -- -_. # #2 BCW / #6 AWG \ MGB & BOT. AGB COAX. ATTACH COAX TO CABLE TRA ANTENNA ANT. MOUNT ANT. MOUNT ANT. MOUNT 41 1 • 1 • WITH CABLE TIES, 6' O.C. GROUND EACH GROUND BAR \ #6 AWG • e • • • e COAX CABLE TO ANTENNA GROUND BAR WITH COAXIAL GROUND KIT. ROUTE COAX CABLE ALONG BALLAST MOUNT, AS I SECTOR BUS SECTOR BUS SECTOR BUS CLOSE TO ANTENNA AS POSSIBLE. I I #2 BCW A 10/6/05 FOR REVIEW #2 AWG TNN COPPER CLAD SOLID \ / 2/0 BCW TO BUILDING CADWELD FROM ANTENNA GROUND TOP AGB WATER MAIN IN GARAGE PROFESSIONAL STAMP BAR TO BALLAST MOUNT s • • • • SPRINKLER ROOM r COAXIAL CABLE ANDTOFr FOLLOW COAX �.� ��M F RUN TO MAIN NOTE: ` r� BALLAST MOUNT GROUNDING 2 GROUND BAR IN r.o JAIMES P. ti CONDUIIT SIZE AS SHOWN ON DWG 1. BOND ANTENNAS GROUNDING KIT CABLE TO TOP AGB '° '°�= � EQUIPMENT ROOM 4 o SYROKE m SCALE: N.T.S. G-1 2. BOND ANTENNA GROUNDING KIT CABLE TO BOT AGB r. No- INSULATED GROUNDING BUSHING )2oos8 0 Z GEDNEY TYPE HBLG SCHEMATIC GRIOUNDING DIAGRAM 4 e SIZE TO SUIT CEILING OF NEXTEL ROOM SCALE: N.T.S. BURNDY CRIMP, TYP #C AWG BCW - A STAINLESS STEEL HARDWARE MICROFLECT 16—PORT VINTERIOR GROUND HALO Q ENTRY PORT #2 AWG GREEN STRANDED 0TWO HOLE COPPER #2/0 AWG GREEN ` NEXTEL PROVIDE SURGE GROUNDING CABLE---,-. COMPRESSION TERMINAL DRAWN BY: G.A.M. INSULATED SUPPRESSOR RACK INSIDE VIEW PANDUIT STANDOFF, 16" O.C., HUBS, TWO HOLE MOUNTED W/ 3/8" HORIZ. & VERT. (P/N: PP2S-S10-X) STRAIGHT TONGUE, THREADED ROD ATTACH HALO TO STANDOFF WITH GROUND BAR CHECKED BY: M.N. T & B NATURAL NYLON CABLE TIES. ELEVATION A SIZE TO SUIT 4S I GARAGE LEVEL, FIRE #2 AWG GREEN STRANDED STAR WASHER (TYP.) FLAT WASHER (TYP.) SITE ADDRESS: PUMP/SPRINKLER ROOM 1/2"x1 1/2" HEX BOLT ONE CAROL WAY #6 AWG GREEN STRANDED NUT (TYP.) SALEM , MA TO SURGE SUPPRESSOR GROUND BAR HEAVY DUTY WATER Im goo 70 TO STREET PIPE GROUND CLAMP 0 GROUND COAX PORT BURNDY TYPE NSNT/NI+NT OR GAR—TC GROUND BAR SIZE TO SUIT MASTER GROUND BAR (MGB) 000000000°°°°°°°00000° SHEET TITLE: °°°°°°°°°°°°°°°°°°°°°° GROUNDING CABLE EXPOSED BARE COPPER TO BE KEPT TO ABSOLUTE MINIMUM, NO INSULATION ALLOWED WITHIN THE GROUNDING #2 STRANDED TO GROUND SECTION 'A-ACOMPRESSION TERMINAL (TYP.) GROUNDING — STANDARD DETAIL WATER MAIN OUTSIDE ROOM 1. DOUBLING UP OR STACKING OF CONNECTIONS IS NOT PERMITTED DETAILS I 2. OXIDE INHIBITING COMPOUND TO BE USED AT ALL LOCATIONS. WATER MAIN GROUNDING r3 SCALE: N.T.S. G-, TYP. MECHANICAL CONNECTION SHEET NUMBER: WAVEGUIDE GROUNDING 5 6 S T. . SCALE:NTS G_� SCALE: N. G-1