72 Loring Ave., Salem, MA Tedeschi Interior Remodel Permit SetTITLE SHEETT100 DOCUMENT LISTT100TITLE SHEETREVISION NUMBERREVISION INDICATORREFERENCE NUMBERWINDOW SYMBOLNEW EQUIPMENT/ ITEMLOCATIONELEVATIONDATUM POINTSECTION DETAILREFERENCE I.D.SHEET NUMBERXXXXXXXXXX9'-0" AFFTYPE 313'-0" A.F.F.LEVEL 2TEXT NOTE NUMBERKEYED NOTE DESIGNATORGRAPHIC SYMBOLSABBREVIATIONSENLARGED DETAILREFERENCE NUMBERSHEET NUMBERROOM IDENTIFICATIONREFERENCE NAMEREFERENCE NUMBERELEVATIONREFERENCE I.D.SHEET NUMBERDOOR SYMBOLREFERENCE NUMBERCEILING HEIGHT KEYHEIGHTMATERIAL TYPE100WD100XXA400ACDBA5001A5001MOISTURE RESISTANTNOT IN CONTRACTPLASTIC LAMINATEREVISION(S) REVISEDAIR CONDITIONINGHEATING/VENTILATION/HDWHVACHDWDINSULINTHMINTERIORINSULATIONHARDWOODHARDWAREHOLLOW METALWDVCTVESTTYPWOODVESTIBULETYPICALEXTERIOR INSULATIONGYPSUM WALL BOARDEIFSFT (')GWB/GYPFDF.R.FINFLEXTFLOOR DRAINFIRE RATEDEXTERIORFINISH(ED)FEET, FOOTFLOOR(ING)DWGEXISTEL./ELEVEQEXPEADIMDNDTLDIAEXISTINGEACHELEVATIONEQUALEXPOSEDDETAILDOWNDIMENSIONDIAMETERDRAWINGSTRUCTSUSPTELSSSIMSCSPECSCHEDSECSTRUCTURALSUSPENDEDSTAINLESS STEELTELEPHONESOLID CORESCHEDULESIMILARSECTIONSPECIFICATION(S)REQ'DRMROREVLPREFPLWDPROJROUGH OPENINGREQUIREDROOMPLYWOODPROJECTPLATEREFERENCE ABOVE FINISHED FLOORAIR CONDITIONINGARCHITECT(URAL)CONCRETE MASONRY UNITBLDGCONSTCONTCONCCLGCMUCLRCOLCLBOT / B.O.CONTINUOUSCONSTRUCTIONCLEARCOLUMNCONCRETEBUILDINGBOTTOM / BOTTOM OFCENTER LINECEILINGARCHABVAFFA/CABOVEOPN'GP-LAMOCOPPNTSNICON CENTEROPENINGOPPOSITE (HAND)NOT TO SCALEM.R.MISCMFRMECHMANUFACTURE(R)MECHANICALMISCELLANEOUSLANDLORDLLALUMALUMINUMBITBITUMINOUSFIBERGLASSFGGAGAUGEGALVGALVANIZEDGLGLASSJTJOINTHORIZHORIZONTALMAXIMUM/MINIMUMMAX/MINMTLMETALPRE-MOLDED JOINT FILLERPMJFPANELPNLVINYL COMPOSITION PREFABPRE-FABRICATEDPSIPOUNDS PER SQUARE INCHPTPRESSURE TREATEDREINFREINFORCEDT>ONGUE AND GROOVE T.O.TOP OFVERTVERTICALWWF/WWMWELDED WIRE F.R.T.FIRE RETARDANT TREATEDFINISH SYSTEMFABRIC (MESH)TILEEX100EXISTING / DEMO FLOOR PLAN AND NOTESA100PROPOSED FLOOR PLAN AND NOTESNUMBERDRAWING TITLEPERMIT ISSUE DATE:
05/22/2017
ISSUE DATE:
ISSUE DATE
ISSUE DATE G.C. IS RESPONSIBLE FOR KEEPING A CURRENT RECORD SET OF DRAWINGS ON SITE DURING CONSTRUCTION. G.C. SHALL TURN OVER A COPY OF THE DRAWINGS TO THE ARCHITECT AND/OR CLIENT/LL AS REQUIRED.GENERAL NOTESC UPLAND ARCHITECTS, INC
ISSUED FOR:PERMIT REVIEWDATE ISSUED:05/22/17PROJECT TITLE:DRAWING TITLE:PERMIT DWG DATE:05-22-2017PROJECT NUMBER:16-128DRAWN BY:NSCHECKED BY:GJSDRAWING NUMBER:REVISIONS:NUMBER:REMARKS:DATE: DISCLAIMEROWNERSHIP AND USE OF DOCUMENTS, DRAWINGS ANDSPECIFICATIONS ARE INSTRUMENTS OF PROFESSIONALSERVICE AND SHALL REMAIN THE PROPERTY OF THEARCHITECT. THESE DOCUMENTS ARE NOT TO BE USED,IN WHOLE OR IN PART, FOR ANY OTHER PROJECTS ORPURPOSES OR BY ANY OTHER PARTIES THAN THOSEPROPERLY AUTHORIZED BY CONTRACT WITHOUT THEEXPRESS WRITTEN AUTHORIZATION OF THE ARCHITECT.250 E. MAIN STREETSUITE 13NORTON, MASSACHUSETTS02766T 774-430-3390WWW.UPLANDARCHITECTS.COM7ELEVENSTORE NUMBER: 3750872 LORING AVE.SALEM, MA 01970F.E.FIRE EXTINGUISHERC.G.CORNER GUARDSFSQUARE FOOTV.I.F.VERIFY IN FIELDE.T.R.EXISTING TO REMAINFIELD VERIFYF.V.ABOVE FINISHED GRADEA.F.G.7-ELEVENSTORE NUMBER: 3750872 LORING AVE.SALEM, MASSACHUSETTS 01970RNKEY PLANLOCUS PLANA200REFLECTED CEILING PLAN SCHEDULE AND NOTESA101FINISH PLAN AND NOTESEX200EXISTING / DEMO CEILING PLAN AND NOTESRRXTEXT NOTE NUMBERRELOCATED EQUIPMENT/ ITEMTEXT NOTE NUMBERREMOVED EQUIPMENT/ ITEMTEXT NOTE NUMBER CODE SUMMARYAPPLICABLE CODES BUILDING CODE: INTERNATIONAL BUILDING CODE, ED. 2009 : 780 CMR - MASSACHUSETTS AMENDMENTS (8TH EDITION) EXISTING BUILDING CODE: INTERNATIONAL EXISTING BUILDING CODE, ED. 2009 ACCESSIBILITY CODE: 521 CMR MA ACCESSIBILITY REGULATIONS PLUMBING CODE: MASS STATE PLUMBING CODE, 248 CMR 10.00: UNIFORM STATE PLUMBING CODE MECHANICAL CODE: INTERNATIONAL MECHANICAL CODE, ED. 2009 : ELECTRICAL CODE: NATIONAL ELECTRICAL CODE, ED. 2014 : 527 CMR - MA FIRE PROTECTION AND ELECTRICAL REGULATIONS FIRE PROTECTION: INTERNATIONAL FIRE CODE, ED. 2009 : 527 CMR - MA FIRE PROTECTION AND ELECTRICAL REGULATIONS ENERGY: INTERNATIONAL ENERGY CONSERVATION CODE, ED. 2009PROJECT NARRATIVE :THIS PROJECT IS A TENANT "FIT UP" FOR AN EXISTING CONVENIENCE STORE AT AN EXISTING TENANT SPACE IN AN EXISTING BUILDING. THE SCOPE OF WORK INCLUDES INTERIOR FINISHES, RELOCATING REPLACING EQUIPMENT, & MINOR INTERIORCONSTRUCTION.DESCRIPTIONCODE REFERENCEREQUIREMENTPROPOSEDGENERALLEVEL 2 ALTERATION REQUIREMENTS: IEBC 701: COMPLY W/ IEBC CH. 6&7 AND IBC SECTIONS - USE GROUP: 309.1: M: M - CONSTRUCTION TYPE: TABLE 601: 5B ASSUMED: 5B ASSUMED - NO. OF STORIES (TENANT): TABLE 503: 1: 1 E.T.R. - COVERED MALL: 402.0: NO: NO - SPRINKLERED: 903.2.7: NO: YES, E.T.R. - MANUAL FIRE ALARM SYSTEM: 907.2.7: NO: YES, E.T.R. - AUTOMATIC FIRE ALARM SYSTEM: PER MECHANICAL CODE: NO: YES, E.T.R. - VESTIBULE REQUIRED (ENTER TO SPACE 3,000 S.F. +)ENERGY CODE: IECC 502.4.7: NO: NOSEPARATIONSLEVEL 2 ALTERATION REQUIREMENTS: IEBC 701: COMPLY W/ IEBC CH. 6&7 AND IBC SECTIONS - TENANT SEPARATION: TABLE 601/508.2N/AN/A - FINISH CLASSIFICATION: TABLE 803.9: EXIT ENCLOSURES AND PASSAGE WAYS: CLASS A: CLASS A: CORRIDORS: CLASS B: CLASS B: ROOMS AND ENCLOSED SPACES: CLASS C: CLASS COCCUPANT LOAD SUMMARY: - GROSS FLOOR AREA::: 3,163 SQ.FT. TOTAL-FLOOR AREA ALLOWANCE: TABLE 1004.1.1: SALES 30 S.F.6)§-: TABLE 1004.1.1: STOCK 300 SF6)§TOTAL OCCUPANT LOAD: 63 OCC LOADEGRESS - REQUIRED NUMBER OF EXITS: 1021: 1: 2 ETR - MIN. EXIT SEPARATION: 1015.2.1: 84'-0" / 2 = 42'-0" MIN. SEP.: 53'-0" - MAXIMUM EGRESS PATH: TABLE 1016.1: 200 FEET MAX: 143'-0" - EXIT PASSAGEWAY (SERVING MORE THAN 50 OCCUPANTS): 1023.2: 44 INCHES: 44" - EXIT PASSAGEWAY ( SERVING LESS THAN 50 OCCUPANTS): 1023.2: 36 INCHES: N/APLUMBING FACILITIES:SEPARATE FACILITIES REQUIRED: 248 CMR 10.10 .18.i: NO: EMPLOYEE ONLYXXXXXXA102TAGGED EQUIPMENT PLAN AND SCHEDULEXARCHITECTGARY SADLERUPLAND ARCHITECTS250 E. MAIN STREETPH:(774)430-3390 FAX.(774)430-3393PROJECT DIRECTORYBUILDING DEPARTMENTCITY OF SALEMINSPECTIONAL SERVICES120 WASHINGTON ST.FLOOR 3SALEM, MA 01970PH: (978) 619-5640CLIENT:ROYSTON LLC.1556 OLD ELBERT ROADROYSTON, GA 30662CONTACT NAME: BUD DUDLEYPH:(706)680-56347-ELEVEN.HEALTH DEPARTMENTCITY OF SALEM120 WASHINGTON ST.SALEM, MA 01970PH: (978) 741-1800
SPRINKLERSYSTEM PIPES1 SIDEDNOVELTY CASEROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32SUNGLASSESROLLINGGONDOLA38.5X32ROLLINGGONDOLA38.5X32CHIP RACK
FRITO LAYROLLINGGONDOLA38.5X32HILL PHOENIX75X37OPEN AIRHILL PHOENIX4 DOOR LOW TEMP123X37PRINTER12X12POSPOSMONEY
GRAM
HIGH WALL4'HIGH WALL4'HIGH WALL4'BUNNDUALDBCICECOFFEEHOSIZAKIICEMAKERCOPIERHANDDRYERHANDDRYERW/HKENOAREADDATAQQQQDDQQ5'-7 1/2"3'-0"5'-0"3'-6 1/2"5'-0"3'-0 1/2"
4'-1"17'-3 1/2"3'-4"3'-6 3/4"5'-7 3/4"6'-9 1/4"7'-2 1/2"54'-7 1/2"35'-6 3/4"BACKROOMWASHROOMWASHROOMMGR.OFFICE5'-11 1/2"1-DOORICE MERCHCID CASERAISEDPLATFORMSALESWALK-INCOOLERBACKROOM49'-10 3/4"
89'-8 1/2"BEER CAVEDEMOLITION NOTESTEST FOR ASBESTOS PRIOR TO DEMOLITION. ABATEMENT AS REQUIRED TO MEET FEDERAL,STATE AND LOCAL REGULATIONS.REMOVE AND DISPOSE OF EXISTING VINYL FLOORING IN THE SALES AREA.DEMO WALLS PER PLANS. WORK TO INCLUDE REPAIR OF ELECTRICAL, MECHANICAL, AND GWB ASREQ'D.REMOVE ALL ITEMS ATTACHED TO THE WALLS INCLUDING, BUT NOT LIMITED TO MIRRORS, POP,STRIPE, WALL HOOKS, AND PICTURE FRAMES IN PREPARATION FOR APPLICATION OF WALLFINISHES.DEMO ALL SALES CORE INCLUDING EQUIPMENT, SHELVING, COUNTER, CABINETRY, ETC. PERPLAN. COORDINATE STORAGE AND RELOCATION WITH SCOPE OF WORK.SAW CUT FLOORS, REMOVE ALL DEBRIS, PREP TRENCH FOR REQUIRED ELECTRICAL ORPLUMBING RUNS, RE-POUR OF CONCRETE AREAS, AND FINISHES.CUT AND CAP UNUSED UTILITIES BACK TO BENEATH FINISHED SURFACE. PATCH AND PREP TORECEIVE NEW FINISH.REMOVE AND STORE/DISPOSE OF EXISTING REMOTE REFRIGERATION UNITS AS SHOWN.DISPOSAL MUST MEET ENVIRONMENTAL CODES AND REFRIGERANT LINES PUMPED DOWN BYLICENSED BEVERAGE CONTRACTOR.REMOVE AND DISPOSE OF EXISTING WALK-IN GLIDES. PREP TO RECEIVE NEW.C UPLAND ARCHITECTS, INC
ISSUED FOR:PERMIT REVIEWDATE ISSUED:05/22/17PROJECT TITLE:DRAWING TITLE:PERMIT DWG DATE:05-22-2017PROJECT NUMBER:16-128DRAWN BY:NSCHECKED BY:GJSDRAWING NUMBER:REVISIONS:NUMBER:REMARKS:DATE: DISCLAIMEROWNERSHIP AND USE OF DOCUMENTS, DRAWINGS ANDSPECIFICATIONS ARE INSTRUMENTS OF PROFESSIONALSERVICE AND SHALL REMAIN THE PROPERTY OF THEARCHITECT. THESE DOCUMENTS ARE NOT TO BE USED,IN WHOLE OR IN PART, FOR ANY OTHER PROJECTS ORPURPOSES OR BY ANY OTHER PARTIES THAN THOSEPROPERLY AUTHORIZED BY CONTRACT WITHOUT THEEXPRESS WRITTEN AUTHORIZATION OF THE ARCHITECT.250 E. MAIN STREETSUITE 13NORTON, MASSACHUSETTS02766T 774-430-3390WWW.UPLANDARCHITECTS.COM7ELEVENSTORE NUMBER: 3750872 LORING AVE.SALEM, MA 01970EXISTING / DEMOLITIONFLOOR PLAN AND NOTESDEMOLITION FLOOR PLAN1/4" = 1'-0"1LEGENDPARTITIONS, MILLWORK AND CEILINGITEMS TO BE DEMOLISHEDEXISTING PARTITIONS TO REMAIN, PATCH ANDREPAIR AS REQUIRED DUE TO CONSTRUCTION.EX100GENERAL DEMOLITION NOTES1.THE GENERAL CONTRACTOR AND THEIR SUBCONTRACTORS SHALL VERIFY ALL CONDITIONS,DIMENSIONS, ETC. AT THE SITE AND SHALL REPORT ANY DISCREPANCIES TO THEARCHITECT IN WRITING PRIOR TO CONSTRUCTION. COMMENCEMENT OF WORK IMPLIES THEACCEPTANCE OF ALL CONDITIONS. CONTRACTOR SHALL ALSO COORDINATE THE WORKWITH THE WORK OF ALL OTHER TRADES.2.THE GENERAL CONTRACTOR SHALL PROVIDE ALL PROTECTIVE MEASURES FOR THE SAFETYOF THE PUBLIC AND WORKERS DURING THE COURSE OF THE WORK.3.ALL WORK ON THIS PROJECT SHALL BE DONE IN THE BETS WORKMAN-LIKE MANNER.4.THE GENERAL CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR THE EXECUTION OFTHEIR WORK AND FOR ANY CHANGES AND/OR DEVIATIONS FROM DRAWINGS ANDSPECIFICATIONS MADE WITHOUT PRIOR WRITTEN APPROVAL FROM THE OWNER. THE COSTOF CORRECTIONS RESULTING FROM CHANGES AND/OR DEVIATIONS SHALL BE BORNE BYTHE GENERAL CONTRACTOR.5.DESIGN ALTERATIONS MADE WITHOUT THE ARCHITECT'S KNOWLEDGE DURING THE COURSEOF CONSTRUCTION ARE DONE AT THE OWNER'S AND/OR CONTRACTOR'S RISK. THEARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR THE CONSEQUENCES OF SUCHCHANGES.6.THE GENERAL CONTRACTOR SHALL APPLY FOR AND PAY FOR ALL PERMITS REQUIRED FORTHIS PROJECT.7.A COMPLETE SET OF CONTRACT DOCUMENTS MUST BE KEPT AT THE JOB SITE AT ALL TIMESAND ANY CHANGES MUST BE NOTED THEREON AND INITIALED8.THE CONTRACTOR SHALL INSURE THE PROTECTION OF ALL EQUIPMENT FURNISHED UNDERHIS CONTRACT AND BY OTHERS.9.THE GENERAL CONTRACTOR SHALL DO ALL WALL AND FLOOR PATCHING TO CONFORM TOMATERIAL, TEXTURE, AND SURFACE ALIGNMENT WITH THE ADJOINING SURFACE.10.PROVIDE PROTECTION AROUND AREAS WHERE NEW WORK AND/OR DEMOLITION IS TO BEPERFORMED IN ORDER TO PREVENT DUST AND DIRT FROM ENTERING ACTIVE PORTIONS OFTHE BUILDING.11.PATCH, REPAIR, AND/OR REPLACE ALL WORK DAMAGED BY NEW CONSTRUCTION.12.REMOVE ALL DEBRIS AT THE COMPLETION OF THE PROJECT AND PROPERLY DISPOSE OF.13.DO NOT SCALE DRAWINGS FOR ANY REASON. REPORT ANY DIMENSIONAL DISCREPANCIESTO THE ARCHITECT BEFORE CONTINUING WORK.14.WHERE LISTED, PRODUCT DISTRIBUTORS ARE PROVIDED FOR CONVENIENCE ONLY. THECONTRACTOR IS NOT REQUIRED TO USE THE LISTED DISTRIBUTORS.15.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION AS REQUIRED FORCOMPLETION OF THE PROJECT. REMOVE ALL DEMOLISHED MATERIAL, NOT DESIGNATED FORRE-USE, FROM THE PREMISES. LEAVE THE PREMISES CLEAN, NEAT, AND ORDERLY AT THECOMPLETION OF THE PROJECT.16.REPLACE, OR RELOCATE ALL EXISTING PIPING, CONDUIT, WIRING, ETC. REQUIRED FOR THECOMPLETION OF THE NEW WORK.17.THE ARCHITECT HAS NO CONTROL OR RESPONSIBILITY FOR THE MEANS, TECHNIQUESSEQUENCE, OR PROCEDURES OF CONSTRUCTION OR SAFETY PROGRAMS FOR THISPROJECT. SUCH PROGRAMS AND COMPLIANCE WITH ALL LAWS, RULES, REGULATIONS,CODES OR ORDINANCES SHALL BE THE RESPONSIBILITY OF OTHERS.18.THE SUB-CONTRACTORS SHALL APPLY FOR AND PAY FOR ALL TRADE PERMITS REQUIREDFOR THIS PROJECT.19.THE REMOVAL OF FLOOR SLAB FOR INSTALLATION OF SANITARY AND/OR WATER LINESSHALL BE ACCOMPLISHED BY SAW CUTTING.20.PENETRATIONS OF THE ROOF LARGER THAN 2'-0" X 2'-0" FOR THE INSTALLATION OF THEROOF MOUNTED EQUIPMENT SHALL REQUIRE A STEEL SUPPORT FRAME TO CARRY THELOAD TO THE BUILDINGS STEEL STRUCTURE. TENANT IS REQUIRED TO COORDINATE ROOFPENETRATIONS WITH THE LANDLORD'S ROOFING CONTRACTOR21.ANY WORK THAT REQUIRES PENETRATION THE ROOF SYSTEM SHALL BE PERFORMED BY AROOFING CONTRACTOR APPROVED BY THE LANDLORD.22.ELECTRICAL CONDUIT, WATER LINE, DUCT SUPPORTS/HANGERS, ETC. SHALL NOT BEATTACHED TO UNDERSIDE OF THE ROOF DECK. SHALL BE ATTACHED TO TOP CHORD OF BARJOIST ONLY.REFERENCENORTH
SDSDFAN&LIGHTSECURTIY LIGHT
SDFAN&LIGHTSECURTIY LIGHT
SDSDSPRINKLERSYSTEM PIPESSCSCSCSCSCSCSCSCSCSCSCLEDLIGHTSEXISTING INTERIOR LIGHTING LEGENDFIXTUREDESCRIPTIONFIXTUREDESCRIPTION1' X 4' FLUORESCENT FIXTUREJELLY JAR FIXTURE4' X 3" FLUORESCENT FIXTUREJJ2' X 2' AIR DIFFUSERCOMBO EXIT/SECURITY LIGHTCEILING MOUNTED SECURITY CAMERACEILING SPEAKER2' X 2' AIR RETURN CEILING VENT8.5" X 8.5" CEILING VENTSCCEILING MOUNTED ROUND SECURITY CAMERAFLOURESENTLIGHT FIXTURELIGHTFANLIGHT FAN4' X 9" FLUORESCENT FIXTURE8' X 3" FLUORESCENT FIXTUREDEMOLITION CEILING NOTESREMOVE EXISTING LIGHT FIXTURES. MODIFY ELECTRICAL AS REQ'D FOR INSTALLATION OFNEW FIXTURES; SEE A200.REMOVE AND DISPOSE OF UP TO 25 DAMAGED CEILING TILES (LIKE FOR LIKE)REMOVE AND DISPOSE OF INTERIOR LIGHTED SIGNAGE.CLEAN AND PREP CEILING DIFFUSERS AND CEILING GRID FOR NEW FINISH.C UPLAND ARCHITECTS, INC
ISSUED FOR:PERMIT REVIEWDATE ISSUED:05/22/17PROJECT TITLE:DRAWING TITLE:PERMIT DWG DATE:05-22-2017PROJECT NUMBER:16-128DRAWN BY:NSCHECKED BY:GJSDRAWING NUMBER:REVISIONS:NUMBER:REMARKS:DATE: DISCLAIMEROWNERSHIP AND USE OF DOCUMENTS, DRAWINGS ANDSPECIFICATIONS ARE INSTRUMENTS OF PROFESSIONALSERVICE AND SHALL REMAIN THE PROPERTY OF THEARCHITECT. THESE DOCUMENTS ARE NOT TO BE USED,IN WHOLE OR IN PART, FOR ANY OTHER PROJECTS ORPURPOSES OR BY ANY OTHER PARTIES THAN THOSEPROPERLY AUTHORIZED BY CONTRACT WITHOUT THEEXPRESS WRITTEN AUTHORIZATION OF THE ARCHITECT.250 E. MAIN STREETSUITE 13NORTON, MASSACHUSETTS02766T 774-430-3390WWW.UPLANDARCHITECTS.COM7ELEVENSTORE NUMBER: 3750872 LORING AVE.SALEM, MA 01970EXISTING / DEMO. CEILINGPLAN AND NOTESDEMOLITION CEILING PLAN1/4" = 1'-0"1LEGENDPARTITIONS, MILLWORK AND CEILINGITEMS TO BE DEMOLISHEDEXISTING PARTITIONS TO REMAIN, PATCH ANDREPAIR AS REQUIRED DUE TO CONSTRUCTION. EX200GENERAL DEMOLITION NOTES1.THE GENERAL CONTRACTOR AND THEIR SUBCONTRACTORS SHALL VERIFY ALL CONDITIONS,DIMENSIONS, ETC. AT THE SITE AND SHALL REPORT ANY DISCREPANCIES TO THEARCHITECT IN WRITING PRIOR TO CONSTRUCTION. COMMENCEMENT OF WORK IMPLIES THEACCEPTANCE OF ALL CONDITIONS. CONTRACTOR SHALL ALSO COORDINATE THE WORKWITH THE WORK OF ALL OTHER TRADES.2.THE GENERAL CONTRACTOR SHALL PROVIDE ALL PROTECTIVE MEASURES FOR THE SAFETYOF THE PUBLIC AND WORKERS DURING THE COURSE OF THE WORK.3.ALL WORK ON THIS PROJECT SHALL BE DONE IN THE BETS WORKMAN-LIKE MANNER.4.THE GENERAL CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR THE EXECUTION OFTHEIR WORK AND FOR ANY CHANGES AND/OR DEVIATIONS FROM DRAWINGS ANDSPECIFICATIONS MADE WITHOUT PRIOR WRITTEN APPROVAL FROM THE OWNER. THE COSTOF CORRECTIONS RESULTING FROM CHANGES AND/OR DEVIATIONS SHALL BE BORNE BYTHE GENERAL CONTRACTOR.5.DESIGN ALTERATIONS MADE WITHOUT THE ARCHITECT'S KNOWLEDGE DURING THE COURSEOF CONSTRUCTION ARE DONE AT THE OWNER'S AND/OR CONTRACTOR'S RISK. THEARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR THE CONSEQUENCES OF SUCHCHANGES.6.THE GENERAL CONTRACTOR SHALL APPLY FOR AND PAY FOR ALL PERMITS REQUIRED FORTHIS PROJECT.7.A COMPLETE SET OF CONTRACT DOCUMENTS MUST BE KEPT AT THE JOB SITE AT ALL TIMESAND ANY CHANGES MUST BE NOTED THEREON AND INITIALED8.THE CONTRACTOR SHALL INSURE THE PROTECTION OF ALL EQUIPMENT FURNISHED UNDERHIS CONTRACT AND BY OTHERS.9.THE GENERAL CONTRACTOR SHALL DO ALL WALL AND FLOOR PATCHING TO CONFORM TOMATERIAL, TEXTURE, AND SURFACE ALIGNMENT WITH THE ADJOINING SURFACE.10.PROVIDE PROTECTION AROUND AREAS WHERE NEW WORK AND/OR DEMOLITION IS TO BEPERFORMED IN ORDER TO PREVENT DUST AND DIRT FROM ENTERING ACTIVE PORTIONS OFTHE BUILDING.11.PATCH, REPAIR, AND/OR REPLACE ALL WORK DAMAGED BY NEW CONSTRUCTION.12.REMOVE ALL DEBRIS AT THE COMPLETION OF THE PROJECT AND PROPERLY DISPOSE OF.13.DO NOT SCALE DRAWINGS FOR ANY REASON. REPORT ANY DIMENSIONAL DISCREPANCIESTO THE ARCHITECT BEFORE CONTINUING WORK.14.WHERE LISTED, PRODUCT DISTRIBUTORS ARE PROVIDED FOR CONVENIENCE ONLY. THECONTRACTOR IS NOT REQUIRED TO USE THE LISTED DISTRIBUTORS.15.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION AS REQUIRED FORCOMPLETION OF THE PROJECT. REMOVE ALL DEMOLISHED MATERIAL, NOT DESIGNATED FORRE-USE, FROM THE PREMISES. LEAVE THE PREMISES CLEAN, NEAT, AND ORDERLY AT THECOMPLETION OF THE PROJECT.16.REPLACE, OR RELOCATE ALL EXISTING PIPING, CONDUIT, WIRING, ETC. REQUIRED FOR THECOMPLETION OF THE NEW WORK.17.THE ARCHITECT HAS NO CONTROL OR RESPONSIBILITY FOR THE MEANS, TECHNIQUESSEQUENCE, OR PROCEDURES OF CONSTRUCTION OR SAFETY PROGRAMS FOR THISPROJECT. SUCH PROGRAMS AND COMPLIANCE WITH ALL LAWS, RULES, REGULATIONS,CODES OR ORDINANCES SHALL BE THE RESPONSIBILITY OF OTHERS.18.THE SUB-CONTRACTORS SHALL APPLY FOR AND PAY FOR ALL TRADE PERMITS REQUIREDFOR THIS PROJECT.19.THE REMOVAL OF FLOOR SLAB FOR INSTALLATION OF SANITARY AND/OR WATER LINESSHALL BE ACCOMPLISHED BY SAW CUTTING.20.PENETRATIONS OF THE ROOF LARGER THAN 2'-0" X 2'-0" FOR THE INSTALLATION OF THEROOF MOUNTED EQUIPMENT SHALL REQUIRE A STEEL SUPPORT FRAME TO CARRY THELOAD TO THE BUILDINGS STEEL STRUCTURE. TENANT IS REQUIRED TO COORDINATE ROOFPENETRATIONS WITH THE LANDLORD'S ROOFING CONTRACTOR21.ANY WORK THAT REQUIRES PENETRATION THE ROOF SYSTEM SHALL BE PERFORMED BY AROOFING CONTRACTOR APPROVED BY THE LANDLORD.22.ELECTRICAL CONDUIT, WATER LINE, DUCT SUPPORTS/HANGERS, ETC. SHALL NOT BEATTACHED TO UNDERSIDE OF THE ROOF DECK. SHALL BE ATTACHED TO TOP CHORD OF BARJOIST ONLY.REFERENCENORTH
SPRINKLERSYSTEM PIPESHILL PHOENIX75X37OPEN AIRHILL PHOENIX4 DOOR LOW TEMP123X37MONEY
GRAM
HANDDRYERHANDDRYERW/H1-DOORICE MERCHWALK-INCOOLERBACKROOMBEER CAVECHILLERTEABREWER
SLURP2-3CDIFCB-ADASLURP2-3CDIFCB-ADAFSDM3-5CDI-FS16-ADAPOST MIXREMOTE ICE MAKERREMOTE3 BRLSLURPREMOTE3 BRLSLURP3' 'T'3' 'T'3' 'T'3' 'T'6"H T-UNIT EXTENSION6"H T-UNIT EXTENSION6"H T-UNIT EXTENSION6"H T-UNIT EXTENSION3' 'T'6"H T-UNIT EXTENSION3' 'T'6"H T-UNIT EXTENSION36"Lx20"(or22")Wx80"HDUNNAGE RACKCO236"Lx20"(or22")Wx80"HDUNNAGE RACK5'-4 1/4"5'-0"36"X18" METALSHELF (5-TIER)3'-7 1/2"3' 'T'3' 'T'6"H T-UNIT EXTENSION6"H T-UNIT EXTENSION4'-6"3' 'T'6"H T-UNIT EXTENSION3' 'T'3' 'T'6"H T-UNIT EXTENSION6"H T-UNIT EXTENSION3' 'T'3' 'T'6"H T-UNIT EXTENSION6"H T-UNIT EXTENSION4'-8 1/2"6'-0"NEWSPAPERNEWSPAPER48"X18" METALSHELF (5-TIER)48"X18" METALSHELF (5-TIER)48"X18" METALSHELF (5-TIER)48"X18" METALSHELF (5-TIER)4'-8 1/2"5'-11"36"X18" METALSHELF (5-TIER)M3F47-2 BACKROOM FREEZER36"X18" METALSHELF (5-TIER)3'-0 3/4"DEMO AROUNDCOLUMN. TALK ABOUTWATER ANDELECTRICAL DURINGPRE-CON.RELOCATEKENOMONITORS48"X18" METALSHELF (5-TIER)DO NOT DEMOPLATFORM INOFFICE4'-0 1/4"3'-6 1/2"3' 'T'6"H T-UNIT EXTENSION3' 'T'6"H T-UNIT EXTENSION3' 'T'6"H T-UNIT EXTENSION3'-6"3'-8"GC TO INSTALL A CONDUITFROM THE ADJOINING BANK(PHONE DENMARK) TOENABLE WIC AND FIRE ALARM2 USE.FFTM2-42DADABBE3-3CDI/API-ICE COFADAFFTM2-42DADAVAULTDOLLYORACLE: 32032HANDLES: 10735QTY: 6VAULTDOLLYORACLE: 32032HANDLES: 10735QTY: 64' HIGH PROFILE4'CIG7'-1"8'-0 1/4"3' 'T'6"H T-UNIT EXTENSIONNOVELTYBASKETSNEEDED4'-8 1/2"9'-2"5'-9 1/4"3'-7"ADDITIONALSHELVESNEEDED FOROACBUILDING DIAGONAL108'-0"141'-5"BUILDING DIAGONAL53'-0"6'-6"6'-6"BUILDING DIAGONAL89'-0"CONSTRUCTION NOTESGENERAL MAINTENANCE AS REQUIRED. G.C. TO COORDINATE WITH OWNER'S REP FOR SCOPE.DEEP CLEAN STORE AS REQ'D BY OWNER'S REP.PROVIDE DUMPSTER. SERVICE TO INCLUDE DELIVERY, PICK-UP AND ALL NECESSARY DISPOSALTRIPS. PROVIDE STORAGE POD ON SITE FOR STORAGE OF ALL EQUIPMENT AND MATERIALS.REPLACE EXTERIOR PARKING SIGNS, TO INCLUDE HANDICAP & 7-ELEVEN SPECIFIC SIGNAGE.PROVIDE & INSTALL EXTERIOR UPRIGHT TRASH CANS (2) FOR CUSTOMER USE. LOCATION ASDIRECTED BY TENANT. PAINT BOLLARDS PER OWNER REP SPECS.LABOR AND MATERIAL TO INSTALL NEW CERAMIC FLOOR TILE IN SALES AREA. PREP AND REPAIRFLOOR AS NECESSARY TO RECEIVE NEW TILE. INCLUDES INSTALL OF VINYL COVE BASE.PAINT STORE INTERIOR, & INTERIOR HEADERS, PER FINISH PLAN.PREP AND INSTALL PVC (OR FRP) WALL PANEL IN ALL FOOD PREP AREAS AND AREAS AS DIRECTEDBY 7 ELEVEN REP, INSTALL VINYL COVE BASE (CONTRACTOR TO PROVIDE). WOOD DOORS TO BECOVERED WITH PVC. ALL REFRIGERATION, PLUMBING, & ELECTRICAL LINES NEED TO BE RUNINSIDE THE WALL. IF UNABLE TO RUN INSIDE THE WALL, FURNISH AND INSTALL A STAINLESS STEELCHASE. ALL SWITCHES AND OUTLETS SHOULD BE CHANGED TO STAINLESS STEEL (CONTRACTORTO FURNISH). ALL SWITCH PLATE COVERS ARE TO BE STAINLESS STEEL OVERSIZED COVERS(CONTRACTOR TO PROVIDE). NOMINALLY 100-150 LINEAR FEET; $65 LINEAR FOOT ADDITIONAL.INSTALL SUBWAY WALL TILE AND LINEN MARRONE WALL TILE, PER SPECS.INSTALL STAINLESS STEEL CORNER GUARDS ON COLUMNS - 10" LENGTH.INSTALL NEW DOOR ANNOUNCERS. SPEC: RODANN ENTRANCE ALERT SET TX-1000 AND RX-1000RECEIVER. A TYPICAL SET REQUIRES THE TX-1000 AND 2 ADDITIONAL RECEIVERS.SUPPLY AND INSTALL NEW FRONT ENTRANCE DOOR HANDLES, BOTH INSIDE AND OUTSIDE, PER7-ELEVEN SPECS.INSTALL TRI-STRIPE FILM AND FROSTING PER 7-ELEVEN SPECIFICATIONS. REFER TO INSTALLATIONGUIDELINES. MATERIAL SUPPLIED BY 7-ELEVEN.PAINT DOORS AND TRIM VISIBLE TO SALES AREA. INTERIOR - DARK TAN (464C) STANTEST ENAMEL(OIL BASED) FOR (DOORS AND FRAMES ONLY).INSTALL PANIC HARDWARE FOR EMERGENCY EXITS (EMERGENCY ALARM BATTERY OPERATEDALARM PANIC BAR W/ NEW BATTERY).INSTALL NEW MANAGER'S OFFICE DOOR HARDWARE: QTY 1 - LOCK SET W/ DEAD BOLT & THUMBLATCH (ITEM 28-8G37 LB 26D SGT). QTY 2 - DOOR VIEWER (ITEM 8271 190 DEGREE UL 26D MAG).OTHER 3 DOORS: QTY 3 - BUTTS (ITEM TA2714 4-1/2" X 4-1/2" NRP 26D MCK), PLUS QTY 1 - STOP(ITEM GJ FB14 26D GJ), PLUS QTY 1 - CLOSER (ITEM 1431-0 EN SGT)INSTALL NEW SATIN STAINLESS STEEL KICK PLATE ON SPECIFIED DOORS. SPEC: HOME DEPOTSPEC KICK PLATE 34"X34"X0.050 SATIN STAINLESS STEEL.INSTALL 7-ELEVEN SPEC CLOCK AND STRIPE, INCLUDING ELECTRICAL, PER FINISH PLAN.INSTALL NEW MERCHANDISING EQUIPMENT, COUNTERS, SHELVING PER PLAN, INCLUDING ANYGENERAL & FILTERED WATER / PLUMBING LINES / DRAIN LINES, AND ELECTRICAL LINES. INSTALLALL IN WALLS; IF NOT POSSIBLE, FURNISH AND INSTALL CHASE.REMOVE & RELOCATE EXISTING EQUIPMENT. COORDINATE NEW EQUIPMENT LOCATION WITH PLANLAYOUT. COORDINATE PLUMBING / ELECTRICAL REQUIREMENTS WITH EQUIPMENTSPECIFICATIONS AND SCOPE OF WORK DOCUMENTRELOCATE SAFE, INCLUDING REQ'D ELECTRICAL, PER PROPOSED PLAN.INSTALL NEW SINK IN NEW / EXISTING LOCATION. TIE INTO EXISTING PLUMBING.INSTALL 7-ELEVEN SPEC WATER FILTRATION SYSTEM. CONTRACTOR TO INSURE THAT ALLEQUIPMENT REQUIRING FILTERED WATER (INCLUDING, BUT NOT LIMITED TO POST MIX, ICEMAKERS, SLURPEE'S, CAPPUCCINO, ICE TEA BREWER, COFFEE BREWERS, AND CHILLERS) ISSUPPLIED FILTERED WATER FROM THE NEW FILTRATION SYSTEMINSTALL NEW POST MIX ICE MAKER - REMOTE. PROVIDE LABOR AND MATERIALS REQUIRED FORINSTALLATION: INCLUDES ELECTRICAL, ROOF PENETRATIONS, ROOF CURBING, ROOF FLASHINGAND SEALINGINSTALL NEW FLOOR DRAIN AT NEW POST MIX AND SLURPEE LOCATIONINSTALL NEW DEDICATED CIRCUIT WITH QUAD OUTLET FOR ATM & DUPLEX OUTLET FOR ATMSIGNAGE.INSTALL WALL MOUNTED AND METRO SHELVING AT WALK-IN COOLER / VAULT, BACKROOM AND ATOTHER AREAS WHERE SPACE PERMITS, AND AS DIRECTED BY 7-ELEVEN REP.REPLACE EXISTING VAULT GLIDES WITH NEW ROLLER GLIDES PER OWNER SPECS.REMOVE AND REINSTALL EXISTING REMOTE / SELF CONTAINED UNIT PER PLAN. COORDINATEPLUMBING AND ELECTRICAL NEEDS AS REQUIRED AND INCLUDE IN PRICING.EXISTING RESTROOM TO REMAIN. CLEAN AND CAULK ALL EXISTING FIXTURES. INSTALLOCCUPANCY SENSOR SWITCH IN EXISTING REST ROOMS.INSTALL BACK FLOW PREVENTERS AS REQUIRED BY CITY.INSTALL NEW BIB RACK, RUN NEW LINES.REMOVE AND REINSTALL AUTOMATIC HAND DRYERSINSTALL NEW PRESSURE-ASSISTED TOILET. AMERICAN STANDARD ONE-PIECE TOILET#705-FLOOR-WHITEINSTALL NEW HAND SINK. AMERICAN STANDARD #0356.015.REMOVE AND REINSTALL EXISTING REMOTE 4 DOOR UNIT IN NEW LOCTION. COORDINATE IN FIELD.PROPOSED FLOOR PLANAND NOTESFIRST FLOOR PLAN1/4" = 1'-0"1A100GENERAL CONSTRUCTION NOTES1.THE GENERAL CONTRACTOR AND THEIR SUBCONTRACTORS SHALL VERIFY ALLCONDITIONS, DIMENSIONS, ETC. AT THE SITE AND SHALL REPORT ANY DISCREPANCIES TOTHE ARCHITECT IN WRITING PRIOR TO CONSTRUCTION. COMMENCEMENT OF WORK IMPLIESTHE ACCEPTANCE OF ALL CONDITIONS. CONTRACTOR SHALL ALSO COORDINATE THE WORKWITH THE WORK OF ALL OTHER TRADES.2.THE GENERAL CONTRACTOR SHALL PROVIDE ALL PROTECTIVE MEASURES FOR THESAFETY IF THE PUBLIC AND WORKERS DURING THE COURSE OF THE WORK.3.ALL WORK ON THIS PROJECT SHALL BE DONE IN THE BEST WORKMAN-LIKE MANNER.4.THE GENERAL CONSTRUCTION SHALL ASSUME ALL RESPONSIBILITY FOR THE EXECUTIONOF HIS WORK AND FOR ANY CHANGES AND/OR DEVIATIONS FROM DRAWINGS ANDSPECIFICATIONS MADE WITHOUT PRIOR WRITTEN APPROVAL FROM THE OWNER. THE COSTOF CORRECTIONS RESULTING FROM CHANGES AND/OR DEVIATIONS SHALL BE BORNE BYTHE GENERAL CONTRACTOR.5.DESIGN ALTERATIONS MADE WITHOUT THE ARCHITECT'S KNOWLEDGE DURING THECOURSE OF CONSTRUCTION ARE DONE AT THE OWNER'S AND/OR CONTRACTOR'S RISK.THE ARCHITECT SHALL NOT BE HELD RESPONSIBLE FOR THE CONSEQUENCES OF SUCHCHANGES.6.THE GENERAL CONTRACTOR SHALL APPLY FOR AND PAY FOR ALL PERMITS REQUIRED FORTHIS PROJECT.7.A COMPLETE SET OF CONTRACT DOCUMENTS MUST BE KEPT AT THE JOB SITE AT ALL TIMESAND ANY CHANGES MUST BE NOTED THEREON AND INITIALED8.THE CONTRACTOR SHALL INSURE THE PROTECTION OF ALL EQUIPMENT FURNISHED UNDERHIS CONTRACT AND BY OTHERS.9.THE GENERAL CONTRACTOR SHALL DO AL WALL AND FLOOR PATCHING TO CONFORM TOMATERIAL, TEXTURE, AND SURFACE ALIGNMENT WITH THE ADJOINING SURFACE.10.PROVIDE PROTECTION AROUND AREAS WHERE NEW WORK AND/OR DEMOLITION IS TO BEPERFORMED IN ORDER TO PREVENT DUST AND DIRT FROM ENTERING ACTIVE PORTIONS OFTHE BUILDING.11.PATCH, REPAIR, OR REPLACE ALL WORK DAMAGED BY NEW CONSTRUCTION.12.REMOVE ALL DEBRIS AT THE COMPLETION OF THE PROJECT AND PREPARE / DISPOSE OF.13.DO NOT SCALE DRAWINGS FOR ANY REASON. REPORT ANY DIMENSIONAL DISCREPANCIESTO THE ARCHITECT BEFORE CONTINUING WORK.14.WHERE LISTED, PRODUCT DISTRIBUTORS ARE PROVIDED FOR CONVENIENCE ONLY. THECONTRACTOR IS NOT REQUIRED TO USE THE LISTED DISTRIBUTORS.15.THE ARCHITECT HAS NO CONTROL OR RESPONSIBILITY FOR THE MEANS, TECHNIQUESSEQUENCE, OR PROCEDURES OF CONSTRUCTION OR SAFETY PROGRAMS FOR THISPROJECT. SUCH PROGRAMS AND COMPLIANCE WITH ALL LAWS, RULES, REGULATIONS,CODES OR ORDINANCES SHALL BE THE RESPONSIBILITY OF OTHERS.16.THE SUB-CONTRACTORS SHALL APPLY FOR AND PAY FOR ALL TRADE PERMITS REQUIREDFOR THIS PROJECT.17.THE REMOVAL OF FLOOR SLAB FOR INSTALLATION OF SANITARY AND/OR WATER LINESSHALL BE ACCOMPLISHED BY SAW CUTTING.18.PENETRATIONS OF THE ROOF LARGER THAN 2'-0" X 2'-0" FOR THE INSTALLATION OF THEROOF MOUNTED EQUIPMENT SHALL REQUIRE A STEEL SUPPORT FRAME TO CARRY THELOAD TO THE BUILDINGS STEEL STRUCTURE. TENANT IS REQUIRED TO COORDINATE ROOFPENETRATIONS WITH THE LANDLORD'S ROOFING CONTRACTOR19.ANY WORK THAT REQUIRES PENETRATION THE ROOF SYSTEM SHALL BE PERFORMED BY AROOFING CONTRACTOR APPROVED BY THE LANDLORD.20.ELECTRICAL CONDUIT, WATER LINE, DUCT SUPPORTS/HANGERS, ETC. SHALL NOT BEATTACHED TO UNDERSIDE OF THE ROOF DECK. SHALL BE ATTACHED TO TOP CHORD OFBAR JOIST ONLY.21.G.C. TO NOTIFY OWNER AND ARCHITECT OF ANY CHANGES TO PARTITION LOCATIONS. G.C.IS RESPONSIBLE TO COORDINATE AS BUILT WALL LOCATIONS WITH MILLWORK VENDER TOINSURE PROPER INSTALLATION OF ALL MILLWORK22.G.C. IS RESPONSIBLE FOR PROTECTING ALL CONSTRUCTION AS REQUIRED TO PREVENTDAMAGE TO NEW CONSTRUCTION. IT IS THE G.C. RESPONSIBILITY TO REPLACE ALLDAMAGED ITEMS PRIOR TO OWNER TURNOVER.EXISTING PARTITION TO REMAIN, PATCH ANDREPAIR AS REQUIRED DUE TO CONSTRUCTION.NEW PARTITION CONSTRUCTIONLEGENDC UPLAND ARCHITECTS, INC
ISSUED FOR:PERMIT REVIEWDATE ISSUED:05/22/17PROJECT TITLE:DRAWING TITLE:PERMIT DWG DATE:05-22-2017PROJECT NUMBER:16-128DRAWN BY:NSCHECKED BY:GJSDRAWING NUMBER:REVISIONS:NUMBER:REMARKS:DATE: DISCLAIMEROWNERSHIP AND USE OF DOCUMENTS, DRAWINGS ANDSPECIFICATIONS ARE INSTRUMENTS OF PROFESSIONALSERVICE AND SHALL REMAIN THE PROPERTY OF THEARCHITECT. THESE DOCUMENTS ARE NOT TO BE USED,IN WHOLE OR IN PART, FOR ANY OTHER PROJECTS ORPURPOSES OR BY ANY OTHER PARTIES THAN THOSEPROPERLY AUTHORIZED BY CONTRACT WITHOUT THEEXPRESS WRITTEN AUTHORIZATION OF THE ARCHITECT.250 E. MAIN STREETSUITE 13NORTON, MASSACHUSETTS02766T 774-430-3390WWW.UPLANDARCHITECTS.COM7ELEVENSTORE NUMBER: 3750872 LORING AVE.SALEM, MA 01970REFERENCENORTHNEW PARTITION CONSTRUCTION
F6F9SPEC TILEWORKREQUIRED INRESTROOMSPEC TILEWORKREQUIRED INRESTROOMF1F2FINISH SCHEDULEMARCO MAPLE PANELINGINTERCERAMIC: BRITE ULTRAWHITE 3"X6" SUBWAY TILE W/ 18"POLYBLEND, UNSANDED GROUT(VAULT)INTERCERAMIC: LINEN MARRONE16"X24" W/ 316" POLYBLEND,SANDED NEW TAUPE GROUT LINE(HOT FOOD)INTERCERAMIC: BOSTON BEIGE16"X24" FLOOR TILE W/ 316"POLYBLEND, SANDED NEW TAUPEGROUT LINESTAINLESS CORNER TRIMPAINT WHITEPAINT GECKO GREEN--SHERWINWILLIAMS 6719 SATIN FINISH7-11 CLOCK AND STRIPEPAINT--BENJAMIN MOORE,BLEEKER BEIGE--HC-80. USEEMERALD OR DURATION HOMEAS BASE.F3F4F5F7F8F1F1F7F1F7F1F7F1F7F7F1F1F1F1F1F1F1F1F1F1F1F1F1F1F1F2F2F2F2F2F2F2F2F2F3F3F4F5F5F5F5F5F5F5F5F6F6F6F6F6F8F9F9F9F9F9F9F9FINISH PLAN AND NOTESFINISH PLAN1/4" = 1'-0"1A101C UPLAND ARCHITECTS, INC
ISSUED FOR:PERMIT REVIEWDATE ISSUED:05/22/17PROJECT TITLE:DRAWING TITLE:PERMIT DWG DATE:05-22-2017PROJECT NUMBER:16-128DRAWN BY:NSCHECKED BY:GJSDRAWING NUMBER:REVISIONS:NUMBER:REMARKS:DATE: DISCLAIMEROWNERSHIP AND USE OF DOCUMENTS, DRAWINGS ANDSPECIFICATIONS ARE INSTRUMENTS OF PROFESSIONALSERVICE AND SHALL REMAIN THE PROPERTY OF THEARCHITECT. THESE DOCUMENTS ARE NOT TO BE USED,IN WHOLE OR IN PART, FOR ANY OTHER PROJECTS ORPURPOSES OR BY ANY OTHER PARTIES THAN THOSEPROPERLY AUTHORIZED BY CONTRACT WITHOUT THEEXPRESS WRITTEN AUTHORIZATION OF THE ARCHITECT.250 E. MAIN STREETSUITE 13NORTON, MASSACHUSETTS02766T 774-430-3390WWW.UPLANDARCHITECTS.COM7ELEVENSTORE NUMBER: 3750872 LORING AVE.SALEM, MA 01970REFERENCENORTH
EX-IMEX-LT4018990EX-19111370086306306EX-OAC1204008142378EX-SAFE857287286574360198838284SPRINKLERSYSTEM PIPESHILL PHOENIX75X37OPEN AIRHILL PHOENIX4 DOOR LOW TEMP123X37MONEY
GRAM
HANDDRYERHANDDRYERW/H1-DOORICE MERCHWALK-INCOOLERBACKROOMBEER CAVECHILLERTEABREWER
SLURP2-3CDIFCB-ADASLURP2-3CDIFCB-ADAFSDM3-5CDI-FS16-ADAPOST MIXREMOTE ICE MAKERREMOTE3 BRLSLURPREMOTE3 BRLSLURP3' 'T'3' 'T'3' 'T'3' 'T'6"H T-UNIT EXTENSION6"H T-UNIT EXTENSION6"H T-UNIT EXTENSION6"H T-UNIT EXTENSION3' 'T'6"H T-UNIT EXTENSION3' 'T'6"H T-UNIT EXTENSION36"Lx20"(or22")Wx80"HDUNNAGE RACKCO236"Lx20"(or22")Wx80"HDUNNAGE RACK36"X18" METALSHELF (5-TIER)3' 'T'3' 'T'6"H T-UNIT EXTENSION6"H T-UNIT EXTENSION3' 'T'6"H T-UNIT EXTENSION3' 'T'3' 'T'6"H T-UNIT EXTENSION6"H T-UNIT EXTENSION3' 'T'3' 'T'6"H T-UNIT EXTENSION6"H T-UNIT EXTENSIONNEWSPAPERNEWSPAPER48"X18" METALSHELF (5-TIER)48"X18" METALSHELF (5-TIER)48"X18" METALSHELF (5-TIER)48"X18" METALSHELF (5-TIER)36"X18" METALSHELF (5-TIER)M3F47-2 BACKROOM FREEZER36"X18" METALSHELF (5-TIER)48"X18" METALSHELF (5-TIER)3' 'T'6"H T-UNIT EXTENSION3' 'T'6"H T-UNIT EXTENSION3' 'T'6"H T-UNIT EXTENSIONFFTM2-42DADABBE3-3CDI/API-ICE COFADAFFTM2-42DADAVAULTDOLLYORACLE: 32032HANDLES: 10735QTY: 6VAULTDOLLYORACLE: 32032HANDLES: 10735QTY: 64' HIGH PROFILE4'CIG3' 'T'6"H T-UNIT EXTENSION701EX-POSEX-LOTTOEX-LOTTOEX-MGEX-ATMEX- 3COMPEX-HS25ITEM NO.QTYDESCRIPTIONMANUFACTURERPART NUMBER231High Flow Plus (Pn 9347-10) Filtration System W/ Filters AndSurge Tank, W/O LpaPentair Filtration Solutions Llc9347-1025110 Box, 10 Pump 2 Wide Bib RackLancer Corporation85-1803-020401A651Panasonic Ne-17571 1700 Watt MicrowaveEttinger-Rosini & Assoc IncNE-17571741Chili Cheese Dispenser - 8mhpde2-120v Peristaltic Dispenser,Accy Kit 8mhpd2-711-P-KStar Manufacturing Int'L IncHPD2-120V781Model 690-16 Food WarmerWisco Industries Inc690-16821Turbochef Encore Oven, Preloaded Menu, 2 Solid Baskets, 2Mesh Screens, 1 Baking Stone, 1 Baking Rack, And 2 Bottles OfCleanerTurnkey ResourcesENC-9500-40831Freezer Counter, Work Top, One Section, 27" Wide, 7.0 CubicFeet, Ada Model, Sneezeguard, 1 Yr WarrantyTurbo Air IncMUF-28-711S-ADA841Refrigerated Counter, Work Top, Left Hinge, One Section, 27"Wide, 7.0 Cubic Feet, Ada Model, Sneezeguard - All StainlessExterior, 1 Yr WarrantyTurbo Air IncMUR-28-711S-ADA851Hfd Case, Tempered Glass, 16 Serving Pans, 4 Anodized DimplePizza Pans, 115/1/60 Elec Required. Replaces # 06170165Sanden Vendo America IncHFD000006861Two Head Refrigerated Dispenser With Ice Coffee Graphics -Includes Standard 1 Year Parts And Labor Warranty For IcedCoffee DispenserKan Pak LlcCDG-211IC891Two Head Refrigerated Dispenser With Bulk Cream Graphics -Includes Standard 1 Year Parts And Labor Warranty For BulkCream DispenserKan Pak LlcCDG-211901New Cappuccino Machine, Imix5s PlusBunn O Matic Corporation38100.03511131FS30/16 soda dispenser, ADA button set-up, LED w/splashguards, no flavor shots, 30"Wx27"D bin adapter, warrantyincludedLancer Corporation85-14816-00-711LA1201Reach-In Freezer,Two-Section,54" Wide, 47 Cubic Feet - AllStainless Exterior - 18 Months WarrantyTurbo Air IncM3F47-21981Counter, Sink, 34h, Cab-24x29 Door, Top-Flat Ss 24x30,Sink-15x15, 12x16x12 Splash Guard, Legs; Cream Sk2-30d-AdaRoyston Llc60057466-01230623 Brl Fbd 563, Remote Unit, Light Door Box, And 1 YearWarrantyFbd Partnership LpFBD 563 REMOTE3601Refrigerated Condiment Station, One Section, 27" Wide, 7.3Cubic Feet, Sneezeguard, Ada Model - 1 Yr WarrantyTurbo Air IncMST-28-711S-ADA4001Two Batch Thermal Fresh Brewer System, Dual Tf Dbc (Short),Stainless SteelBunn O Matic Corporation34600.00394018Tf Server New Style, 1 Gallon, Digital Sight Gauge, CountdownTimerBunn O Matic Corporation42700.00027001Iced Tea/Coffee Brewer (Long Island Test 2013)-Itb DdilW/SweetenerBunn O Matic Corporation41400.00037011Iced Tea/Coffee Dispenser (Long Island Test 2013)Bunn O Matic Corporation396007282Hrs-45 Roller GrillApw/Wyott Corp218316458141Counter, Sink, 34h, Cab-24x29 Door, Top-Flat Ss 24x30,Sink-19x18 Ext Sprayer Faucet, 3-Sided 12" Splash Guard, Legs;Cream Sk2-30d-Esf-AdaRoyston Llc60020935-012EX- 3COMP13 COMP SINK 72"X23"N/AN/AEX-1911Shelving, Highwall Pastry Case B 36Wx30Dx62H - Black / CreamRoyston Llc70014700-012EX-ATM1ATMN/AN/AEX-HS1Hand Sink, Existing 12"X14"N/AN/AEX-IM1Ice Merchandiser. Existing.N/AN/AEX-LOTTO2Existing LotteryN/AN/AEX-LT14-Door Low Temp Freezer. Existing.Hill PhoenixN/AEX-MG1Existing Money Gram MachineN/AN/AEX-OAC1Open Air Case, Existing.Hill PhoenixN/AEX-POS2Existing Point of Sale RegistersNCRN/AEX-SAFE1Scd/Tube Vend, 2 Single Feed Cash Code ValidatorsTidel Engineering LpTIDELTAGGED EQUIPMENT PLANAND SCHEDULEEQUIPMENT PLAN1/4" = 1'-0"1A102C UPLAND ARCHITECTS, INC
ISSUED FOR:PERMIT REVIEWDATE ISSUED:05/22/17PROJECT TITLE:DRAWING TITLE:PERMIT DWG DATE:05-22-2017PROJECT NUMBER:16-128DRAWN BY:NSCHECKED BY:GJSDRAWING NUMBER:REVISIONS:NUMBER:REMARKS:DATE: DISCLAIMEROWNERSHIP AND USE OF DOCUMENTS, DRAWINGS ANDSPECIFICATIONS ARE INSTRUMENTS OF PROFESSIONALSERVICE AND SHALL REMAIN THE PROPERTY OF THEARCHITECT. THESE DOCUMENTS ARE NOT TO BE USED,IN WHOLE OR IN PART, FOR ANY OTHER PROJECTS ORPURPOSES OR BY ANY OTHER PARTIES THAN THOSEPROPERLY AUTHORIZED BY CONTRACT WITHOUT THEEXPRESS WRITTEN AUTHORIZATION OF THE ARCHITECT.250 E. MAIN STREETSUITE 13NORTON, MASSACHUSETTS02766T 774-430-3390WWW.UPLANDARCHITECTS.COM7ELEVENSTORE NUMBER: 3750872 LORING AVE.SALEM, MA 01970REFERENCENORTHTAGGED EQUIPMENT SCHEDULE
SDFAN&LIGHTSECURTIY LIGHT
SDFAN&LIGHTSECURTIY LIGHT
SDSDSPRINKLERSYSTEM PIPESLEDLIGHTS4' LED TUBE4' LED TUBE4' LED TUBE4' LED TUBE4' LED TUBE4' LED TUBE4' LED TUBE4' LED TUBE4' LED TUBE4' LED TUBE4' LED TUBE4' LED TUBEBBFLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTLED LIGHTRLED LIGHTLED LIGHTLED LIGHTLED LIGHTEMERGENCYLEDEEMERGENCYLEDEEMERGENCYLEDEEMERGENCYLEDEEMERGENCYLEDEEMERGENCYLEDEEMERGENCYLEDEEMERGENCYLEDEEMERGENCYLEDE2' X 2' RECESSEDLED LIGHT2' X 2' RECESSEDLED LIGHTWITH BATTERY BACKUPJELLY JARLED LIGHT4' LED TUBEPROPOSED INTERIOR RCP LEGENDFIXTUREDESCRIPTIONFIXTUREDESCRIPTIONFIXTUREDESCRIPTIONFIXTUREDESCRIPTIONLED LIGHTEMERGENCYLEDE4' LED TUBEJJRRELOCATED ITEMRNEW EXIT LIGHTREMOVE ITEMBBFBATTERYBACKUP FIXTURE4' VAPOR TIGHT FIXTURE4' VAPOR TIGHT FIXTUREFOR VAULTLED LIGHT1' X 4' SURFACE MOUNTEDLED LIGHT1' X 4' SURFACE MOUNTEDLED LIGHTWITH BATTERY BACKUPLED LIGHTEMERGENCYEXISTINGSPRINKLER HEADCEILING NOTESINSTALL EXTERIOR LED BUILDING LIGHTS PER CLIENT SPEC.REPLACE DAMAGED CEILING TILES (APPROX. 25), LIKE FOR LIKE. EXTEND CEILING GRID @DEMO SITES AND INSTALL NEW CEILING TILES.PAINT EXISTING CEILING GRID. COLOR: BENJAMIN MOORE DOVE WING OC-18 OR MATCHEXISTING.CLEAN AND PAINT CEILING DIFFUSERS.PROVIDE & INSTALL NEW 2'x2' STANDARD & BATTERY BACKUP LED LIGHT FIXTURES.GENERAL CONTRACTOR TO ENSURE THAT NEW LIGHTING LAYOUT MEASURES 73 - 89FOOT-CANDLES USING A CALIBRATED LIGHT METER 3' ABOVE FINISHED FLOOR. INCLUDELABOR TO REMOVE EXISTING CEILING TILE FROM ABOVE FOOD PREP AREAS AND REPLACETILES AS REQ'D ON SALES FLOOR FOR LED INSTALLATION.INSTALL 4FT FIXTURES FOR LED BULBSINSTALL ALL HANGING SIGNS PER SCOPE OF WORK.EXISTING SPRINKLER HEADS TO REMAIN. FIELD VERIFY AND COORDINATE AS NEEDED.REFLECTED CEILING PLAN,SCHEDULE & NOTESREFLECTED CEILING PLAN1/4" = 1'-0"1A200IT SHALL BE THE RESPONSIBILITY OF THE PAINTING SUBCONTRACTOR TO PAINT EXPOSEDTRIMS ON ALL CEILING MOUNTED EQUIPMENT (INCLUDES TRACK LIGHT FIXTURES, SPEAKERTRIMS, JUNCTION BOX PLATES, HVAC GRILLES, ETC.) TO MATCH ACOUSTICAL TILE/ GYPSUMBOARD CEILING ADJACENT COLOR PRIOR TO INSTALLATION, UNLESS INDICATEDOTHERWISE.16.SPACING OF HANGERS FOR SUSPENDED CEILING MUST NOT BE MORE THAN 48" O.C.,SPLAYED HANGERS MUST BE PROVIDED OR INTERMEDIATE HANGERS FROM SUPPLEMENTALSTEEL MUST BE SUPPLIED. USE #12 HANGER WIRES 48" O.C. FOR SUPPORTING THEACOUSTICAL CEILING GRID.ALL DIMENSIONS TO BE MEASURED FROM THE FACE OF FINISHED PARTITIONS.ALIGN SOFFITS WITH PARTITIONS AND/OR PARTITION EDGES WHERE APPLICABLE, UNLESSINDICATED OTHERWISE.ELECTRICAL SUBCONTRACTOR SHALL ADJUST TRACK FIXTURES AND ADJUSTABLEDOWNLIGHTS AS PER OWNER'S AND/OR ARCHITECT'S DIRECTION. ELECTRICALSUBCONTRACTOR SHALL PROVIDE AN ON-SITE EXPLANATION OF THE LIGHTING ANDELECTRICAL SYSTEMS TO THE OWNER.SUSPENDED ACOUSTICAL GRID SHALL BE CENTERED WITHIN EACH SPACE UNLESSINDICATED OTHERWISE BY A SPECIFIC DIMENSION OR AN INDICATED GRID STARTING POINT.WHERE ANY SUSPENDED ACOUSTICAL TILE CEILING IS ADJACENT TO A GYPSUM BOARDCEILING, THE GENERAL CONTRACTOR SHALL COORDINATE INSTALLATION TO PROVIDEMATCHING FINISH HEIGHTS OF EACH CEILING, UNLESS INDICATED OTHERWISE.ALL LIGHTS, SPEAKERS AND OTHER CEILING MOUNTED EQUIPMENT SHALL BE CENTERED INTHE CEILING TILE UNLESS INDICATED OTHERWISE. IN SPLINE CEILING, DIMENSIONS FORLIGHTS ARE APPROXIMATE TO THE CENTER OF THE TILE.GENERAL CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE FINISH CEILINGWITH ALL APPLICABLE TRADES TO ASSURE PROPER ALIGNMENT OF: LIGHT FIXTURES,MECHANICAL GRILLS, LIGHTS, EXIT SIGNS, AUDIO SPEAKERS, ETC. VERIFY ANY EQUIPMENTDISCREPANCIES WITH THE ARCHITECT, PRIOR TO INSTALLATION OF THAT EQUIPMENT.PROVIDE CEILING FINISHES AND HEIGHTS AS INDICATED ON THE REFLECTED CEILING PLAN,UNLESS NOTED OTHERWISE7.6.5.4.THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL SUBCONTRACTORTO PROVIDE PROPER SUPPORT OR BLOCKING REQUIRED FOR ALL PENDANT MOUNTEDLIGHT FIXTURE(S)/ TRACKS(S).THE AUDIO SUBCONTRACTOR IS RESPONSIBLE FOR DESIGNATING SPEAKER LOCATIONSTHROUGHOUT THE FACILITY. FOR PROPER INSTALLATION OF AUDIO EQUIPMENT, THE AUDIOSUBCONTRACTOR SHALL COORDINATE ANY PROVISIONS NECESSARY BY THE GENERALCONTRACTOR AND ALL APPLICABLE TRADES. THE GENERAL CONTRACTOR SHALL CUT ALLREQUIRED OPENINGS IN ACOUSTICAL TILE/ GYPSUM BOARD CEILINGS, AS REQUIRED FORTHE AUDIO SUBCONTRACTOR (VERIFY IN FIELD BY OWNER).10.9.8.15.14.13.12.FINISHED ACOUSTICAL TILE CEILING HEIGHT TO BE DETERMINED THROUGH FIELDOBSERVATIONS AND SET AS PERMITTED BY STRUCTURE AND MECHANICAL SYSTEMS -VERIFY WITH THE ARCHITECT PRIOR TO INSTALLATION.11.REFER TO MECHANICAL DRAWINGS FOR GRILL & DIFFUSER LOCATIONS.3.GENERAL CEILING NOTES1.2.17.SUPPLY AND INSTALL STAINLESS STEEL CLOSURE PIECE ABOVE WALK-IN COOLER.REFER TO ELECTRICAL DRAWINGS FOR CEILING SPEAKER SPECIFICATIONS AND LOCATIONSREFER TO ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING SPECIFICATIONS ANDLOCATIONSALL LIGHTING FIXTURE HEIGHTS TBD BY OWNER18.C UPLAND ARCHITECTS, INC
ISSUED FOR:PERMIT REVIEWDATE ISSUED:05/22/17PROJECT TITLE:DRAWING TITLE:PERMIT DWG DATE:05-22-2017PROJECT NUMBER:16-128DRAWN BY:NSCHECKED BY:GJSDRAWING NUMBER:REVISIONS:NUMBER:REMARKS:DATE: DISCLAIMEROWNERSHIP AND USE OF DOCUMENTS, DRAWINGS ANDSPECIFICATIONS ARE INSTRUMENTS OF PROFESSIONALSERVICE AND SHALL REMAIN THE PROPERTY OF THEARCHITECT. THESE DOCUMENTS ARE NOT TO BE USED,IN WHOLE OR IN PART, FOR ANY OTHER PROJECTS ORPURPOSES OR BY ANY OTHER PARTIES THAN THOSEPROPERLY AUTHORIZED BY CONTRACT WITHOUT THEEXPRESS WRITTEN AUTHORIZATION OF THE ARCHITECT.250 E. MAIN STREETSUITE 13NORTON, MASSACHUSETTS02766T 774-430-3390WWW.UPLANDARCHITECTS.COM7ELEVENSTORE NUMBER: 3750872 LORING AVE.SALEM, MA 01970REFERENCENORTH