Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
190 MARLBOROUGH ROAD - BUILDING INSPECTION
_gHW49d® flo UPC 10330 ;� No._153L_ 'teT HASTINGS, NN Certificate Number: B-16-441 Permit Number: B-16-441 Commonwealth of Massachusetts City of Salem This is to Certify that the One Family Dwelling Building located at Building Type Address 19.0_ M_ A_R__L_B__OROU_GH ROAD in the City of Salem "--""""- Town/City Name r IS HEREBY GRANTED A PERMANENT CERTIFICATE OF OCCUPANCY Single Family Home This Permit is granted in conformity with the Statutes and Ordinances relating thereto, and expires ._..____.___NotApvlicable unless sooner suspended or revoked. Expiration Date Issued On: Thursday, January 19, 2017 Commonwealth of Massachusetts ` Citv of Salem a 9 4 120 Washington Sl,3rd Floor Salem,MA 01970(978)745-9595 x5641 ` Return card to Building Division for Certificate of Occupancy Permit No. B-16-441 PERMIT T O BUILD FEE PAID: $1,589.00 DATE ISSUED: 5/9/2016 This certifies that 186-190 MARLBOROUGH ROAD REALTY TRUST THE BOCHES has permission to erect, alter, or demolish a building 190 MARLBOROUGH ROAD Map/Lot: 100032-0 as follows: New Construction - 1-2 Family BUILD NEW SINGLE FAMILY HOME Contractor Name: BRIAN BOCHES DBA: COASTLINE CONSTRUCTION Contractor License No: CS-045576 iiii t 5/9/2016 Building Official Date This permit shall be deemed abandoned and invalid unless the work authorized by this permit is commenced within six months after issuance.The Building Official may grant one or more extensions not to exceed six months each upon written request. All work authorized by this permit shall conform to the approved application and the approved construction documents for which this permit has been granted. All construction,alterations and changes of use of any building and structures shall be in compliance with the local zoning by-laws and codes. This permit shall be displayed in a location clearly visible from access street or road and shall be maintained open for public inspection for the entire duration of the work until the completion of the same. The Certificate of Occupancy will not be issued until all applicable signatures by the Building and Fire Officials are provided on this permit. HIC#: 106095 'Persons contracting with unregistered contractors do not have access to the guaranty fund'(as set forth in MGL c.142A). Restrictions: Building plans are to be available on site. All Permit Cards are the property of the PROPERTY OWNER. Commonwealth of Massachusetts /t q, I P� a e City of Salem ' m 120 Washington St,3rd Floor Salem,MA 01970(978)745-9595 x5641 Return card to Building Division for Certificate of Occupancy Structure CITY OF SALEM BUILDING PERMIT PERMIT TO BE POSTED IN THE WINDOW Excavation Footing INSPECTION RECORD Foundation Framing 3� J Mechanical Insulation b 7 INSPECTION: BY DATE 0 Chimney/Smoke Chamber Final Iii/If l� umbing/Gas Rough:Plumbingh ,ll Ad Rough:Gas (0 Final Or B/—I 0—t 7 Electrical Service Rough 6 ^ �v Final .01 Fire Department Preliminary Final LHealth Department Preliminary Final CITY OF SALEM �� 85a `ig67 ROUTING SLIP New Construction Certificate of Occupancy_ LOCATION 19 011rI t DATE AS ORS DATE Washington St. 000O LERK DATE Washington St. 0SERVICES DATE hington St. 0iV<ER DATE /120 Washington St. fj SS CONNECTION DATE- 0040 5 Jefferson Ave Y/J� PLANNING DATE S 120 Washington St. rr / CONSERVATIO D TE I 120 Washington St. ECTRICAL DATE 48 Lafayette St. PREVENTION DATE Fort Avenue 1 ALTH DATE 120 Was SL BUILDING INSPECTOR DATE 120 Washington St. �� I (IIII IIIIIIII IIIIIIIIilllll SO,ESSEX #45 805412 Pg;444 11/25/2016 09:42 COMPLI Pg 1/3 Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands DEP File Number: WPA Form 86 — Certificate of Compliance 64-597 Massachusetts Wetlands Protection Act M.G.L. c. 131, §40 Provided by DEP A. Project Information Important: When filling out 1. This Certificate of Compliance is issued to: forms on the computer,use Brian Boches only the tab key Name to move your 19 Rezza Road cursor-do not use the return Mailing Address key. Beverly MA 01915 Cityrrown State Zip Code VQ 2. This Certificate of Compliance is issued for work regulated by a final Order of Conditions issued to: Henrie Realty Trust, Stephen Gagnon, Trustee rd" Name 7/15/2015 64-597 Dated DEP File Number 3. The project site is located at: 186-192 Marlborough Road Salem Street Address City/Town 10 32 Assessors Map/Plat Number Parcel/Lot Number the final Order of Condition was recorded at the Registry of Deeds for: Property Owner(if different) South Essex 34751 308 County Book Page Certificate 4. A site inspection was made in the presence of the applicant, or the applicant's agent, on: 11/1412016 Date wpafrmBb.doc•rev.5/29/14 WPA Form 8B,Certificate of Compliance•Page 1 of 3 Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands DEP File Number: WPA Form 8B — Certificate of Compliance 64-597 Massachusetts Wetlands Protection Act M.G.L. c. 131, §40 Provided by DEP B. Certification Check all that apply: Complete Certification It is hereby certified that the work regulated by the above-referenced Order of Conditions has been satisfactorily completed. ❑ Partial Certification: It is hereby certified that only the following portions of work regulated by the above-referenced Order of Conditions have been satisfactorily completed.The project areas or work subject to this partial certification that have been completed and are released from this Order are: ❑ Invalid Order of Conditions: It is hereby certified that the work regulated by the above-referenced Order of Conditions never commenced. The Order of Conditions has lapsed and is therefore no longer valid. No future work subject to regulation under the Wetlands Protection Act may commence without filing a new Notice of Intent and receiving a new Order of Conditions. ❑ Ongoing Conditions: The following conditions of the Order shall continue: (Include any conditions contained in the Final Order, such as maintenance or monitoring, that should continue for a longer period). Condition Numbers: C. Authorization Issued by: Salem Conservation Commission Dag of I uance This Certificate must be signed by a majority of the Conservation Commission and a copy sent to the applicant and appropriate DEP Regional Office(See http://www.mass.gov/eea/agencies/massdeD/about/contarts/). Signal s! ALL LI nafrm8b.doc•rev.5/29/14 WPA Form BB,Certificate of Compliance•Page 2 of 3 Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands DEP File Number: WPA Form 8B — Certificate of Compliance 64-597 Massachusetts Wetlands Protection Act M.G.L. c. 131, §40 Provided by DEP D. Recording Confirmation The applicant is responsible for ensuring that this Certificate of Compliance is recorded in the Registry of Deeds or the Land Court for the district in which the land is located. Detach on dotted line and submit to the Conservation Commission. To: ----------------------------------- ---------------------------- Conservation Commission Please be advised that the Certificate of Compliance for the project at: Project Location DEP File Number Has been recorded at the Registry of Deeds of: County for: Property Owner and has been noted in the chain of title of the affected property on: Date Book Page If recorded land, the instrument number which identifies this transaction is: If registered land, the document number which identifies this transaction is: Document Number Signature of Applicant vrpafrmOodoc•rev.5/29/14 WPA Form 8B,Certificate of Compliance•Page 3 of 3 COMMONWEALTH OF MASSACHUSETTS ESSEX REGISTRY OF DEEDS, S0, DIST., SALEM, MASS ESSEX SS '.Jo J z,-- 20 16 A TRUE COPY OF RECORD: BOOK 35�fTZ PAGEy� ATTEST 999 4 REGISTER '�'STRETCH CODE DUCT ENVELOPE TESTING HERS RATINGS l;1HitJ�v Home Energy Remedies, LLC e�oHome Energy 138 Cedar St 211b NOV —1 P 12: 29 Newton, Ma 02459 (C)508-596-2769 russ@homeenerevremedies.com Coastline Construction November 2, 2016 Brian Boches 19 Rezza Rd Beverly, Ma 09195 Regarding: 190 Marlborough Rd, Salem, Ma Test Date: October 21, 2016 Job#HER-16- 177 Single Home Conditioned area: Conditioned Floor Space 2,272 sq. ft. Measured Ceiling Height 8 ft. Volume 18,176 Cubic ft. Test Results Code Maximum Envelope Leakage CFM50 953 Air Changes per Hour 3.1 7 Stretch Code Prescriptive Rough-in Duct Leakage CFM25 0.06 Total Leakage CFM25 206 0.12 272.6 2nd 1304sf 111 1st 968sf 95 Leakage to outside CFM25 53 0.08 181.8 2nd 1st 53 This house passes the Envelope Leakage and Duct,both Total and To Outside Leakage tests. Blower door almost meets IECC2012 November 2, 2016 - Russell Cole Date HERS Rater 2670237 STRETCH CODE DUCT ENVELOPE TESTING HERS RATINGS 'RETCH CODE DUCT ENVELOPE TESTING HERS RATINGS From IECC 2009 Energy Conservation Code 201 NOV -l P 0 2 9 402.4.2.1 Testing option. Building envelope tightness and insulation installation shall be considered acceptable when tested air leakage is less than seven air changes per hour(ACH) when tested with a blower door at a pressure of 33.5 psf(50 Pa). Testing shall occur after rough in and after installation of penetrations of the building envelope,including penetrations for utilities,plumbing, electrical, ventilation and combustion appliances. 403.2.2 Sealing (Mandatory). All ducts, air handlers,filter boxes and building cavities used as ducts shall be sealed. Joints and seams shall comply with Section M1601.4.1 of the International Residential Code. Duct tightness shall be verified by either of the following: 1. Postconstruction test: Leakage to outdoors shall be less than or equal to 8 cfm (226.5 L/min)per 100 ft2 (9.29 m2) of conditioned floor area or a total leakage less than or equal to 12 cfm(12 L/min)per 100 ft2 (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All register boots shall be taped or otherwise sealed during the test. RESIDENTIAL ENERGY EFFICIENCY 2. Rough-in test: Total leakage shall be less than or equal to 6 cfm (169.9 L/min)per 100 ft2 (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the roughed in system, including the manufacturer's air handler enclosure. All register boots shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 4 cfm (113.3 L/min) per 100 ft2 (9.29 m2)of conditioned floor area. Mass Stretch Code 401.3 Prescriptive Option for Residential Additions. Item 3. Ducts for new HVAC systems shall be sealed and tested post-constructionto demonstrate leakage to outdoors of less thasn or equal to 4 cfm per 100 sq. ft. of conditioned floor area, except where the air handler and all ducts are located within conditioned space STRETCH CODE DUCT ENVELOPE TESTING HERS RATINGS :Y STRETCH CODE DUCT ENVELOPE TESTING HERS RATINGS R s, Home Energy Remedies, LLC Home Energy 138 Cedar St Z01b NOV —1 P 12'- 29 ©_� • Newton, Ma 02459 (C)508-596-2769 russ@homeenergyremedies.com Coastline Construction November 2, 2016 Brian Boches 19 Rezza Rd Beverly,Ma 09195 Regarding: 190 Marlborough Rd, Salem, Ma Test Date: October 21, 2016 Job#HER-16- 177 Single Home Conditioned area: Conditioned Floor Space 2,272 sq. ft. Measured Ceiling Height 8 ft. Volume 18,176 Cubic ft. Test Results Code Maximum Envelope Leakage CFM50 953 Air Changes per Hour 3.1 7 Stretch Code Prescriptive Rough-in Duct Leakage CFM25 0.06 Total Leakage CFM25 206 0.12 272.6 2nd 1304sf 111 1st 968sf 95 Leakage to outside CFM25 53 0.08 181.8 2nd 1st 53 This house passes the Envelope Leakage and Duct, both Total and To Outside Leakage tests. Blower door almost meets IECC2012 November 2, 2016 Russell Cole Date HERS Rater 2670237 STRETCH CODE DUCT ENVELOPE TESTING HERS RATINGS al. STRETCH CODE DUCT ENVELOPE TESTING HERS RATINGS From IECC 2009 Energy Conservation Code tUl� NOV —1 P 12: 21 402.4.2.1 Testing option. Building envelope tightness and insulation installation shall be considered acceptable when tested air leakage is less than seven air changes per hour(ACH) when tested with a blower door at a pressure of 33.5 psf(50 Pa). Testing shall occur after rough in and after installation of penetrations of the building envelope,including penetrations for utilities,plumbing, electrical, ventilation and combustion appliances. 403.2.2 Sealing (Mandatory). All ducts, air handlers, filter boxes and building cavities used as ducts shall be sealed. Joints and seams shall comply with Section M1601.4.1 of the International Residential Code. Duct tightness shall be verified by either of the following: 1. Postconstruction test: Leakage to outdoors shall be less than or equal to S cfm (226.5 L/min)per 100 ft2 (9.29 m2) of conditioned floor area or a total leakage less than or equal to 12 cfm (12 L/min)per 100 ft2 (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All register boots shall be taped or otherwise sealed during the test. RESIDENTIAL ENERGY EFFICIENCY 2. Rough-in test: Total leakage shall be less than or equal to 6 cfm (169.9 L/min)per 100 ft2 (9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the roughed in system, including the manufacturer's air handler enclosure. All register boots shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 4 cfm (113.3 L/min)per 100 ft2 (9.29 m2) of conditioned floor area. Mass Stretch Code 401.3 Prescriptive Option for Residential Additions. Item 3. Ducts for new HVAC systems shall be sealed and tested post-constructionto demonstrate leakage to outdoors of less thasn or equal to 4 cfm per 100 sq. ft. of conditioned floor area, except where the air handler and all ducts are located within conditioned space STRETCH CODE DUCT ENVELOPE TESTING HERS RATINGS