Loading...
15 MAPLE STREET - BUILDING INSPECTION 15 Maple st. UPC 10332 No. 153L HASTINGS, YN Gray Architects, Inc. January 17, 2008 Steven P. Dion Brandi L. Dion 15 Maple St. Salem, MA. 01970 Re: Code Analysis/B&S Sports Science, 142 Canal Street, Salem,MA. and request for Certificate of Occupancy. Dear Brandi and Steve, As we discussed today our office has prepared a Building Code Analysis of the 142 Canal Street as requested by the City of Salem Building Department. To assist in this Analysis we have retained Mr. Peter A. Bryson of Code Consulting Services. Attached to this letter is Mr. Bryson's Code Analysis as well as our Analysis. It is our understanding that some renovations have been undertaken by the building owner in anticipation of code required renovations. I am aware of three items of work that have been started. 1. The construction of a protective wall at the electric panels. 2. The construction of a wall around the sprinkler equipment. 3. The construction of a new accessible toilet. Our review identified other renovations required by the Building Code and I have listed those below. These must be completed prior to the requesting a Certificate of Occupancy. Code Required Renovations 1. Regarding occupancy as it relates to egress facilities and life safety the value of 15 sf per person is reasonable to use based on the specific type of 1 Architecture Planning Landscape Architecture 9A Derby Square Salem,MA 01970 Tel:978 745 4404 Fax:978 745 6479 General e-mail: oravarchitects@msn.com Gray Architects, Inc. use (group exercise) as stimulated in780 CMR 1008. The results is an occupancy of 312. What is required? This will require two independent egress doors equipped with panic hardware and swinging in the direction of egress. 2. While for egress and life safety the capacity of 15 sf per person is required the posted occupancy can be less. It is recommended that an occupancy of 49 persons be used and that any change in use increasing this would require building department approval. What is required? This requires no renovation work but will be made a condition of the Certificate of Occupancy. 3. Regarding the 521 CMR,the Massachusetts State Architectural Access Board Rules and Regulations since under these regulations this is a change of use an accessible route and accessible entrance must be provided. What is required? This will require and accessible entrance door from the exterior. 4. Regarding toilet facilities in accordance with 248 CMR with a minimum of 49 occupants a minimum of one male and one female toilet room with one water closet and one lavatory in each meets the requirement. What is required? 2 Architecture Planning Landscape Architecture 9A Derby Square Salem,MA 01970 Tel:978 745 4404 Fax:978 745 6479 General e-mail: oravarchitects@msn.com Gray Architects, Inc. Since the space currently has toilet facilities no additional toilets are required. The new accessible toilet can be identified as unsex handicap. 5. Regarding ventilation the proposed use should provide ventilation at a minimum of 20 CFM per person. What is required? Using a posted occupancy of 49 this would required a 1000 cfm make- up air unit. Following our meeting this morning I met with the building inspector Tom StPierre and explained our approach to this Code Analysis and the status of the renovations. At this point he is in general agreement with our recommendations. It is also my understanding that prior to issuing the Certificate of Occupancy all work must be completed and inspected by his office. Please contact me if you have any questions. I ;W1 Dennis J. Gray A.I.A., A.S.L.A. President S J.Gq9 FCS\ L No.5185 3 BOSTON, C MAS I 3 Architecture Planning Landscape Architecture 9A Derby Square Salem,MA 01970 Tel:978 745 4404 Fax:978 745 6479 General e-mail: aravarchitects@msn.com CODE REVIEW 142 CANAL STREET,SALEM MA. FOR B&S SPORT SCIENCE January 18,2008 1. This Code Review is specific for the space to be occupied by B&S Sport Science.It does not address any and all code required renovation for other building spaces. EXISTING BUILDING GROSS AREAS Floors: Existing Total gsf First 25,215 25,215 Second 4,325 4,325 29,540 EXISTING USE OR OCCUPANCY A. Storage Use Group"S-1". B. Business use,Use Group `B". PROPOSED CHANGE OF USE OCCUPANCY FOR SPACE USED BY B&S FITNESS C. Use Group`B"(posted occupancy less then 50) CHAPTER 34 3403.1 HAZARD INDEX Table 3403 Use Group Description Hazard Index No. Existing S-1 Storage Moderate Hazard 3 New I B Business 12 GENERAL BUILDING REQUREMENTS A. Area limitations from Table 503: "S-1 Group", Storage, Type 3B: 2 stories above graded = 8,400 gsf B. Area increase: 100% for street frontage= 8,400 200% for sprinkler= 16,800 Total allowable = 33,600 Actual Existing: 25,215 C. Height limitation from Table 503: Allowable: 2 stories plus one story increase for sprinkler, above grade Actual: 2 stories. Gray Architects Inc. CODE REVIEW 142 CANAL STREET,SALEM MA. FOR B&S SPORT SCIENCE January 18,2008 2. CONSTRUCTION TYPE TYPE 311 FROM TABLE 602. REQUIRED ACTUAL REMARKS a. fire walls and party walls 2 b. Enclosure of stairs: 2 c. Exit access: 2 d. Shafts and elevators: 2 e. Structural columns: 0 f. Floor structure: 0 g. Roof structure: 0 h. Mix Use fire Separation 0 No fire separation is required the existing building meets the area limitation of the most restrictive Use Group S-1. CHAPTER 10: MEANS OF EGRESS OCCUPANCS AND MEANS OF EGRESS a. Net sq ft. rented space ground floor: 4680/15 = 312 occupants b. Exit Doors: 2 required MISCELLANIOUS Exit doors must swing in direction of travel and be provided with panic hardware. CHAPTER 9: FIRE PROTECTION SYSTEMS 780 CMR 904 Fire Suppression Systems. A. The building has a sprinkler system that covers this space. 780 CMR 917.0 Fire Protective Signaling System (Fire Alarm System) The building has an approved Fire Protective Signaling System that covers this space. Length of Exit Travel Floor Maximum Existing Comment Gray Architects Inc. CODE REVIEW 142 CANAL STREET,SALEM MA. FOR B&S SPORT SCIENCE January 18,2008 3. (Table 1006.5) (Table Without 1009.4) Sprinkler First 200' 68' 780 CMR 1023.0 EXIT SIGNS AND LIGHTS Illuminated exit signs exist in this space. 780 CMR 1024.0 MEAN OF EGRESS LIGHTING Emergency lighting exists in this space. PLUMBING REQUIREMENTS CMR 105, 410 (State Sanitary Code, Article II, Minimum Standard of Fitness for Human Habitation and shall conform with 248 CMR 2.01(7) Plumbing Requirements Fixture Count: (MA Plumbing Code) WC Lay. Urinal Floor MEN Required Proposed Required Proposed Required Proposed Business 1 1 1 1 25 WOMEN Business 1 1 1 25 Total Fixtures 2 12 2 2 VENTILATION The space must meet the ventilation requirements of the BOCA National Mechanical Code. 20 cfm per person of posted occupance. Gray Architects Inc. CODE REVIEW 142 CANAL STREET,SALEM MA. FOR B&S SPORT SCIENCE January 18,2008 1. This Code Review is specific for the space to be occupied by B&S Sport Science. It does not address any and all code required renovation for other building spaces. EXISTING BUILDING GROSS AREAS Floors: Existing Total gsf First 25,215 25,215 Second 4,325 4,325 29,540 EXISTING USE OR OCCUPANCY A. Storage Use Group "S-111 . B. Business use, Use Group "B". PROPOSED CHANGE OF USE OCCUPANCY FOR SPACE USED BY B&S FITNESS C. Use Group "B" (posted occupancy less then 50) CHAPTER 34 3403.1 HAZARD INDEX Table 3403 Use Group Description Hazard Index No. Existing S-1 Storage Moderate Hazard 3 New I B Business 2 GENERAL BUILDING REQUREMENTS A. Area limitations from Table 503: "S-1 Group", Storage,Type 3B: 2 stories above graded= 8,400 gsf B. Area increase: 100% for street frontage = 8,400 200% for sprinkler= 16,800 Total allowable= 33,600 Actual Existing: 25,215 C. Height limitation from Table 503: Allowable: 2 stories plus one story increase for sprinkler, above grade Actual: 2 stories. Gray Architects Inc. CODE REVIEW 142 CANAL STREET,SALEM MA. FOR B&S SPORT SCIENCE January 18,2008 2. CONSTRUCTION TYPE TYPE 3B FROM TABLE 602. REQUIRED ACTUAL REMARKS a. fire walls and party walls 2 b. Enclosure of stairs: 2 c. Exit access: 2 d. Shafts and elevators: 2 e. Structural columns: 0 f. Floor structure: 0 g. Roof structure: 0 h. Mix Use fire Separation 0 No fire separation is required the existing building meets the area limitation of the most restrictive Use Group S-1. CHAPTER 10: MEANS OF EGRESS OCCUPANCS AND MEANS OF EGRESS a. Net sq ft. rented space ground floor: 4680/15 = 312 occupants b. Exit Doors: 2 required MISCELLANIOUS Exit doors must swing in direction of travel and be provided with panic hardware. CHAPTER 9: FIRE PROTECTION SYSTEMS 780 CMR 904 Fire Suppression Systems. A. The building has a sprinkler system that covers this space. 780 CMR 917.0 Fire Protective Signaling System (Fire Alarm System) The building has an approved Fire Protective Signaling System that covers this space. Length of Exit Travel Floor Maximum Existing Comment Gray Architects Inc. CODE REVIEW 142 CANAL STREET,SALEM MA. FOR B&S SPORT SCIENCE January 18,2008 3. (Table 1006.5) (Table Without 1009.4) Sprinkler First 200' 68' 780 CMR 1023.0 EXIT SIGNS AND LIGHTS Illuminated exit signs exist in this space. 780 CMR 1024.0 MEAN OF EGRESS LIGHTING Emergency lighting exists in this space. PLUMBING REQUIREMENTS CMR 105, 410 (State Sanitary Code, Article II, Minimum Standard of Fitness for Human Habitation and shall conform with 248 CMR 2.01(7) Plumbing Requirements Fixture Count: (MA Plumbing Code) WC Lay. Urinal Floor MEN Required Proposed Required Proposed Required Proposed Business 1 1 1 1 25 WOMEN Business 1 1 1 25 Total Fixtures 1 2 1 2 12 12 VENTILATION The space must meet the ventilation requirements of the BOCA National Mechanical Code. 20 cfm per person of posted occupance. G—'j'9 a necy�i @4•o�t��S J. 6A9 FCJ, No 51 B o 3 ws y (�H 0 Gray Architects hic. 6 b ) �� Plans must be riled and approved by the Inspector before a permit will be granted. No. S6 IV City of Salem Ward I IS PROPERTY LOCATED IN THE HISTORIC DISTRICT? Yes No IF SIDING, HAS ELECTRICAL/Nn J�G� �d PERMIT BEEN OBTAINED? Yes Home Phone # APPLICATION Bus. Phone # FOR PERMIT TO ROOF, REROOF O INSTALL SIDING Salem,Mass., TO THE INSPECTOR OF BUILDINGS: The undersigned herebv applies for a permit to bu,l� ccording to the following specifications: Owner's name and addrep u.= 5 _C.J .S /� %/Ci /,S` Mh FL /t q 7— Architect's name Mechanic's name and addressff=,&Z /rr. 4 Hr e-- 6/-CJD 14 2— C,C,7Y J20 S'rl-C/4x-c Location of building,No. rPe AzS S L,. What is the purpose of building? rvt-in At, n!, T— 0,07 Material of building? 6r Asbestos? Al If a dwelling,for how many families'. _ 9 Will the buildin nn to ,f"�e 'rements a he law? l - 6/ Estimated cost �/ .ontracto o. �- —��'S /06Z7a p0�Z) LSQPaT6FHf ap } ant EMARKS SIGNED UNDER THE PENALTY OF PERJURY. No. d 6 � Ward APPLICATION FOR PERMIT TO ROOF REROOF OR INSTALL SIDING Location PERMIT GRANTED L 19 App v Building Inspector � " 1 City of Salem, Mass. ELECTRICAL DEPARTMENT 44 Lafayette Street PAUL M. TUTTLE , CITY ELECTRICIAN DATE . . . . . . . . . . . . . . . . . . . . . . . . To: INSPECTOR OF BUILDINGS Salem, Mass. J ! j ,!!fr/t/- ----_-- - ---.�_-Electrical Contractor ------- -------- (Slgnature'of Applicant) Jp: . � ?/a� R ,✓E -------------------------------- l ------------------------------------------------------------------------------------------------------ ------ has signified their intention of performing the required electrical work,..viz:-removing and later reall electrical wires, fixtures, receptacles, etc., on Outside of building,located at: `7..-`i_'k,(X- t. Street -- in conjunction wits a wall siding,installation to be made by: 1\ C"I-\ / ��'!,-/_---_---____--_--.---__- SidingContractor ---- ................ ------------------------------------------------------.............................................. ------- ISSUED BY ...... --------- ------ ----------- This is a requirement, preliminary to the issuance of a permit for the sidewall installation by the Inspector of Buildings. ORIGINAL-SIDEWALL INSTALLER PINK COPY-BLDG.INSP. YELLOW COPY-ELEC. FILE