Loading...
UTS Job 23299 Report 5 Compressive Strength Report - Concrete 06-10-2019 (003)-Page 1 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 06-10-2019Compressive Strength Report - Concrete Report No.5 Distribution Copy Job Number 23299 Project North Building,136 Canal St.,Salem, MA Contractor Symes Associates Concrete Co.J.G. Maclellan ALL FIELD TESTS DONE ACCORDING TO ASTM:C-172 C-31 C-143 C-1064 C-39 C-1231ALL COMPRESSIVE STRENGTH TESTS DONE ACCORDING TO ASTM: CLASS CONCRETE:3000# 3/4"No. Of Sets:1 20CUBIC YARDS: SET 1 LOCATION:Wall, column line N at 3.5 Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type B383 4.00 x 8.00 12.57 Good 06/10/19 06/17/19 7 30,000 2,390 2 B384 4.00 x 8.00 12.57 Good 06/10/19 06/24/19 14 37,000 2,940 1 B385 4.00 x 8.00 12.57 Good 06/10/19 07/08/19 28 50,000 3,980 2 B386 4.00 x 8.00 12.57 Good 06/10/19 07/08/19 28 47,500 3,780 3 B387 4.00 x 8.00 12.57 Good 06/10/19 07/08/19 28 48,000 3,820 2 Slump (in.)5 Air Temp. (F.)74 Conc Temp (F)73 Truck No.231 Ticket No.157245 Time 5:15 Unit Wt lbs/cu ft Air Content (%) GENERAL REMARKS:Cylinders received on 06/11/2019; Same day call in. Inspector Premium Travel Name Time Hours Time Chris King No REVIEWED BY:Bryan M. Crabtree FRACTURE TYPES Type 1 Type 2 Type 3 Type 4 Type5 Type 6 Reasonably well-formed Well-formed cone on Columner vertical Diagonal fracture Side fractures at top Similar to Type 5 cones on both ends,one end, vertical cracks cracking through with no cracking or bottom (occur but end of less than 1 in.running through caps,both ends, no through ends; tap commonly with cylinder is [25 mm] of cracking no well-defined cone well-formed cones with hammer to unbonded caps)pointed throught caps on other end distinguish from Type 1 Our reports are available in PDF form via email. Please email us at reports@utsofmass.com for more information. Page 2 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 06-10-2019Compressive Strength Report - Concrete Report No.5 Distribution Copy Job Number 23299 Project North Building,136 Canal St.,Salem, MA Contractor Symes Associates Concrete Co.J.G. Maclellan cc:Symes Associates, Inc. Mark Livesey Seger Architects Dan Ricciarelli McBrie, LLC Michael Perham, P.E. McBrie, LLC Bob Whitton City of Salem Steve Cummings Meninno Construction Tom Pascuccio Page 3 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 06-10-2019Compressive Strength Report - Concrete Report No.5 Distribution Copy Job Number 23299 Project North Building,136 Canal St.,Salem, MA Contractor Symes Associates Concrete Co.J.G. Maclellan FIELD SUMMARY REPORT Total Pour:Wall, column line M-N at 1-6 Method of Placement:Pump Chute Discharge Bucket OtherX Other: Vibrator OtherMethod of Concrete Consolidation:X Other: Cylinder Fabrication Location:Truck Discharge Chute End of Pump HoseX Cylinder Storage:Curing Box Thermal Blanket Hay/Straw Trailer FieldX Other Placement Protection:Thermal Blankets Heat NoneX Other Slump Specification (in.)4-6 Number of slumps out of specification reported to If rejected Approved by Remarks: UTS of Massachusetts, Inc. Page 4 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 06-10-2019 Report No.5 Job Number 23299 Project North Building,136 Canal St.,Salem, MA Attachment