Loading...
UTS Job 22528 Report 25 Compressive Strength Report - Concrete 06-05-2019 Page 1 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 06-05-2019Compressive Strength Report - Concrete Report No.25 Distribution Copy Job Number 22528 Project 11 Dodge Street, Salem, MA Hampton Inn Salem & 231 Washington Contractor Opechee Construction Concrete Co.J.G. Maclellan ALL FIELD TESTS DONE ACCORDING TO ASTM:C-172 C-31 C-143 C-1064 C-39 C-1231ALL COMPRESSIVE STRENGTH TESTS DONE ACCORDING TO ASTM: CLASS CONCRETE:3000# 3/8" *No. Of Sets:6 268CUBIC YARDS: SET 1 LOCATION:Column lines; C.1 at 2.9 Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type A124 4.00 x 8.00 12.57 Good 06/05/19 06/12/19 7 35,500 2,820 1 A125 4.00 x 8.00 12.57 Good 06/05/19 06/19/19 14 45,000 3,580 1 A126 4 x 8 12.57 Good 06/05/19 07/03/19 28 A127 4 x 8 12.57 Good 06/05/19 07/03/19 28 A128 4 x 8 12.57 Good 06/05/19 07/03/19 28 Slump (in.) ** Air Temp. (F.)63 Conc Temp (F)72 Truck No.258 Ticket No.6419 Time 7:20 Unit Wt lbs/cu ft Air Content (%) SET 2 LOCATION:Column lines; Q at 3.5 Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type A129 4.00 x 8.00 12.57 Good 06/05/19 06/12/19 7 36,500 2,900 2 A130 4.00 x 8.00 12.57 Good 06/05/19 06/19/19 14 48,000 3,820 2 A131 4 x 8 12.57 Good 06/05/19 07/03/19 28 A132 4 x 8 12.57 Good 06/05/19 07/03/19 28 A133 4 x 8 12.57 Good 06/05/19 07/03/19 28 Slump (in.)8,7 Air Temp. (F.)66 Conc Temp (F)71 Truck No.202 Ticket No.6932 Time 8:10 Unit Wt lbs/cu ft Air Content (%) SET 3 LOCATION:Column lines N at 4 Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type Z989 4.00 x 8.00 12.57 Good 06/05/19 06/12/19 7 39,000 3,100 2 Z990 4.00 x 8.00 12.57 Good 06/05/19 06/19/19 14 50,000 3,980 2 Z991 4 x 8 12.57 Good 06/05/19 07/03/19 28 Z992 4 x 8 12.57 Good 06/05/19 07/03/19 28 Z993 4 x 8 12.57 Good 06/05/19 07/03/19 28 Slump (in.) ** Air Temp. (F.)66 Conc Temp (F)72 Truck No.242 Ticket No.6944 Time 8:55 Unit Wt lbs/cu ft Air Content (%) SET 4 LOCATION:Column lines; J.6 at 7.1 Page 2 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 06-05-2019Compressive Strength Report - Concrete Report No.25 Distribution Copy Job Number 22528 Project 11 Dodge Street, Salem, MA Hampton Inn Salem & 231 Washington Contractor Opechee Construction Concrete Co.J.G. Maclellan Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type Z984 4.00 x 8.00 12.57 Good 06/05/19 06/12/19 7 41,500 3,300 1 Z985 4.00 x 8.00 12.57 Good 06/05/19 06/19/19 14 54,000 4,300 1 Z986 4 x 8 12.57 Good 06/05/19 07/03/19 28 Z987 4 x 8 12.57 Good 06/05/19 07/03/19 28 Z988 4 x 8 12.57 Good 06/05/19 07/03/19 28 Slump (in.) ** Air Temp. (F.)70 Conc Temp (F)74 Truck No.246 Ticket No.6959 Time 10:05 Unit Wt lbs/cu ft Air Content (%) SET 5 LOCATION:Column lines; C at 7 Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type A148 4.00 x 8.00 12.57 Good 06/05/19 06/12/19 7 33,000 2,630 1 A149 4.00 x 8.00 12.57 Good 06/05/19 06/19/19 14 44,000 3,500 2 A150 4 x 8 12.57 Good 06/05/19 07/03/19 28 A151 4 x 8 12.57 Good 06/05/19 07/03/19 28 A152 4 x 8 12.57 Good 06/05/19 07/03/19 28 Slump (in.)8,7 Air Temp. (F.)72 Conc Temp (F)74 Truck No.241 Ticket No.6967 Time 10:45 Unit Wt lbs/cu ft Air Content (%) SET 6 LOCATION:Column lines F at 18 Total Unit Lab Size Area Date Date Age Load Load Fracture No.(in.)(sq. in.)Condition Cast Tested Days (lbs.)(psi.)Type Z974 4.00 x 8.00 12.57 Good 06/05/19 06/12/19 7 38,500 3,060 2 Z975 4.00 x 8.00 12.57 Good 06/05/19 06/19/19 14 49,000 3,900 3 Z976 4 x 8 12.57 Good 06/05/19 07/03/19 28 Z977 4 x 8 12.57 Good 06/05/19 07/03/19 28 Z978 4 x 8 12.57 Good 06/05/19 07/03/19 28 Slump (in.) ** Air Temp. (F.)75 Conc Temp (F)75 Truck No.258 Ticket No.6983 Time 11:40 Unit Wt lbs/cu ft Air Content (%) GENERAL REMARKS:Cylinders received on 06/05/19. *MRWR **8 1/2, 7 1/2. Early morning rate 6:00am to 7:00am. Inspector Premium Travel Name Time Hours Time Corey Keith No Max Day .5 Hr(s) Chris Grant No Max Day .5 Hr(s) Page 3 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 06-05-2019Compressive Strength Report - Concrete Report No.25 Distribution Copy Job Number 22528 Project 11 Dodge Street, Salem, MA Hampton Inn Salem & 231 Washington Contractor Opechee Construction Concrete Co.J.G. Maclellan REVIEWED BY:Bryan M. Crabtree FRACTURE TYPES Type 1 Type 2 Type 3 Type 4 Type5 Type 6 Reasonably well-formed Well-formed cone on Columner vertical Diagonal fracture Side fractures at top Similar to Type 5 cones on both ends,one end, vertical cracks cracking through with no cracking or bottom (occur but end of less than 1 in.running through caps,both ends, no through ends; tap commonly with cylinder is [25 mm] of cracking no well-defined cone well-formed cones with hammer to unbonded caps)pointed throught caps on other end distinguish from Type 1 Our reports are available in PDF form via email. Please email us at reports@utsofmass.com for more information. cc:Dodge Area, llc Ken McClure Opechee Construction Jeff Daigneault Opechee Construction Jason Blaise City of Salem Steve Cummings Page 4 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 06-05-2019Compressive Strength Report - Concrete Report No.25 Distribution Copy Job Number 22528 Project 11 Dodge Street, Salem, MA Hampton Inn Salem & 231 Washington Contractor Opechee Construction Concrete Co.J.G. Maclellan FIELD SUMMARY REPORT Total Pour:Column lines U at 1, A at 19, SOD, Level 5 Floor Method of Placement:Pump Chute Discharge Bucket OtherX Other: Vibrator OtherMethod of Concrete Consolidation:X Other: Cylinder Fabrication Location:Truck Discharge Chute End of Pump HoseX Cylinder Storage:Curing Box Thermal Blanket Hay/Straw Trailer Field X Other Placement Protection:Thermal Blankets Heat NoneX Other Slump Specification (in.)5 1/2-7 1/2 Number of slumps out of specification reported to If rejected Approved by Remarks: UTS of Massachusetts, Inc. Page 5 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 06-05-2019 Report No.25 Job Number 22528 Project 11 Dodge Street, Salem, MA Hampton Inn Salem & 231 WashingtonAttachment UTS of Massachusetts, Inc. Page 6 5 Richardson Lane, Stoneham, MA 02180 781-438-7755 (Voice) 781-438-6216 (Fax) Report Date 06-05-2019 Report No.25 Job Number 22528 Project 11 Dodge Street, Salem, MA Hampton Inn Salem & 231 WashingtonAttachment